Endress and Hauser Flowtec DMA Flowmeter with Bluetooth LE User Manual Picomag IO Link
Endress&Hauser; Flowtec AG Flowmeter with Bluetooth LE Picomag IO Link
user manual
BA01697D/06/EN/01.17 71370929 Products Solutions Valid as of version 01.00.zz (Device firmware) Operating Instructions Picomag IO-Link Electromagnetic flowmeter Services Picomag IO-Link • Make sure the document is stored in a safe place such that it is always available when working on or with the device. • To avoid danger to individuals or the facility, read the "Basic safety instructions" section carefully, as well as all other safety instructions in the document that are specific to working procedures. • The manufacturer reserves the right to modify technical data without prior notice. Your Endress+Hauser Sales Center will supply you with current information and updates to these instructions. Endress+Hauser Picomag IO-Link Table of contents Table of contents About this document . . . . . . . . . . . . . . . . 4 System integration . . . . . . . . . . . . . . . . 18 1.1 1.2 8.1 8.2 Overview of device description files . . . . . . . . . 18 Device master file . . . . . . . . . . . . . . . . . . . . . 18 Commissioning . . . . . . . . . . . . . . . . . . . . 19 9.1 9.2 1.3 1.4 Document function . . . . . . . . . . . . . . . . . . . . . Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 Safety symbols . . . . . . . . . . . . . . . . . . 1.2.2 Electrical symbols . . . . . . . . . . . . . . . . 1.2.3 Communication symbols . . . . . . . . . . . 1.2.4 Symbols for certain types of information . . . . . . . . . . . . . . . . . . . . 1.2.5 Symbols in graphics . . . . . . . . . . . . . . . Documentation . . . . . . . . . . . . . . . . . . . . . . . . Registered trademarks . . . . . . . . . . . . . . . . . . . Basic safety instructions . . . . . . . . . . . . 6 2.1 2.2 2.3 2.4 2.5 2.6 2.7 Requirements for the personnel . . . . . . . . . . . . Designated use . . . . . . . . . . . . . . . . . . . . . . . . Workplace safety . . . . . . . . . . . . . . . . . . . . . . . Operational safety . . . . . . . . . . . . . . . . . . . . . . Product safety . . . . . . . . . . . . . . . . . . . . . . . . . IT security . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device-specific IT security . . . . . . . . . . . . . . . . . 2.7.1 Access via the SmartBlue App . . . . . . . 2.7.2 Access via Bluetooth® wireless technology . . . . . . . . . . . . . . . . . . . . . Switching ON the measuring device . . . . . . . . Configuring the measuring device . . . . . . . . . . 9.2.1 Configuring the display . . . . . . . . . . . 9.2.2 Configuring system units . . . . . . . . . . 9.2.3 Setting the installation direction and measurement . . . . . . . . . . . . . . . . . . 9.2.4 Configuring the IO modules . . . . . . . . 9.2.5 Simulation . . . . . . . . . . . . . . . . . . . . 21 22 26 10 Operation . . . . . . . . . . . . . . . . . . . . . . . . . 27 10.1 10.2 10.3 Reading measured values . . . . . . . . . . . . . . . . 27 Configuring Bluetooth . . . . . . . . . . . . . . . . . . 28 Administration . . . . . . . . . . . . . . . . . . . . . . . 28 11 Diagnostics and troubleshooting . . . 29 11.1 11.2 11.3 11.4 11.5 11.6 General troubleshooting . . . . . . . . . . . . . . . . . Diagnostic information on local display . . . . . . 11.2.1 Diagnostic message . . . . . . . . . . . . . . Overview of diagnostic events . . . . . . . . . . . . . Pending diagnostic events . . . . . . . . . . . . . . . Device information . . . . . . . . . . . . . . . . . . . . Firmware history . . . . . . . . . . . . . . . . . . . . . 12 Accessories . . . . . . . . . . . . . . . . . . . . . . . 33 13 Technical data . . . . . . . . . . . . . . . . . . . . 34 13.1 13.2 13.3 13.4 13.5 13.6 13.7 13.8 13.9 13.10 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power supply . . . . . . . . . . . . . . . . . . . . . . . . . Performance characteristics . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . Environment . . . . . . . . . . . . . . . . . . . . . . . . . Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical construction . . . . . . . . . . . . . . . . Operability . . . . . . . . . . . . . . . . . . . . . . . . . . Certificates and approvals . . . . . . . . . . . . . . . 14 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . 38 14.1 Radio approvals . . . . . . . . . . . . . . . . . . . . . . . 14.1.1 Europe . . . . . . . . . . . . . . . . . . . . . . . 14.1.2 Canada and USA . . . . . . . . . . . . . . . . 14.1.3 Other countries . . . . . . . . . . . . . . . . . Incoming acceptance and product identification . . . . . . . . . . . . . . . . . . . . . . . 8 3.1 3.2 Incoming acceptance . . . . . . . . . . . . . . . . . . . . 8 Product identification . . . . . . . . . . . . . . . . . . . . 8 3.2.1 Symbols on measuring device . . . . . . . 9 Storage and transport . . . . . . . . . . . . . 10 4.1 4.2 4.3 Storage conditions . . . . . . . . . . . . . . . . . . . . . 10 Transporting the product . . . . . . . . . . . . . . . . 10 Packaging disposal . . . . . . . . . . . . . . . . . . . . . 10 Installation . . . . . . . . . . . . . . . . . . . . . . . 11 5.1 5.2 Installation conditions . . . . . . . . . . . . . . . . . . 11 5.1.1 Mounting position . . . . . . . . . . . . . . . 11 Mounting the measuring device . . . . . . . . . . . 11 Electrical connection . . . . . . . . . . . . . . 13 6.1 6.2 6.3 Connection conditions . . . . . . . . . . . . . . . . . . 6.1.1 Requirements for connecting cables . . 6.1.2 Pin assignment, device plug . . . . . . . . Connecting the measuring device . . . . . . . . . . Post-connection check . . . . . . . . . . . . . . . . . . Operation options . . . . . . . . . . . . . . . . . 17 7.1 Access to the operating menu via the SmartBlue App . . . . . . . . . . . . . . . . . . . . . . . Endress+Hauser 19 19 20 21 13 13 13 15 16 29 30 30 31 32 32 32 34 34 34 34 34 34 35 35 36 36 38 38 38 38 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 17 About this document Picomag IO-Link About this document 1.1 Document function These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal. 1.2 Symbols used 1.2.1 Safety symbols Symbol Meaning DANGER DANGER! This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION CAUTION! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury. NOTICE 1.2.2 NOTE! This symbol contains information on procedures and other facts which do not result in personal injury. Electrical symbols Symbol Meaning Direct current Alternating current Direct and alternating current Ground connection A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system. 1.2.3 Communication symbols Symbol Meaning Bluetooth Wireless data transmission between devices over a short distance. 1.2.4 Symbol Symbols for certain types of information Meaning Permitted Procedures, processes or actions that are permitted. Preferred Procedures, processes or actions that are preferred. Endress+Hauser Picomag IO-Link About this document Symbol Meaning Forbidden Procedures, processes or actions that are forbidden. Tip Indicates additional information. Reference to documentation Reference to page Reference to graphic Notice or individual step to be observed 1. , 2. , 3. … Series of steps Result of a step 1.2.5 Symbols in graphics Symbol Meaning 1, 2, 3, ... Item numbers A, B, C, ... Views 1.3 Documentation For an overview of the scope of the associated Technical Documentation, refer to the following: • The W@M Device Viewer: Enter the serial number of the measuring device (www.endress.com/deviceviewer) • The Endress+Hauser Operations App: Enter the serial number of the measuring device or scan the 2-D matrix code on the measuring device. 1.4 Registered trademarks ® Is a registered trademark. It may only be used in conjunction with products and services by members of the IO-Link Community or by non-members who hold an appropriate license. For more detailed information on the use of IO-Link, please refer to the rules of the IOLink Community at: www.io.link.com. Bluetooth® wireless technology ® The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Endress+Hauser is under license. Apple® Apple, the Apple logo, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Android® Android, Google Play and the Google Play logo are trademarks of Google Inc. Endress+Hauser Basic safety instructions Picomag IO-Link Basic safety instructions 2.1 Requirements for the personnel The personnel for installation, commissioning, diagnostics and maintenance must fulfill the following requirements: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task. ‣ Are authorized by the plant owner/operator. ‣ Are familiar with federal/national regulations. ‣ Before starting work, read and understand the instructions in the manual and supplementary documentation as well as the certificates (depending on the application). ‣ Follow instructions and comply with basic conditions. The operating personnel must fulfill the following requirements: ‣ Are instructed and authorized according to the requirements of the task by the facility's owner-operator. ‣ Follow the instructions in this manual. 2.2 Designated use Application and media The measuring device described in these Brief Operating Instructions is intended only for flow measurement of liquids with a minimum conductivity of 20 µS/cm. To ensure that the measuring device remains in proper condition for the operation time: ‣ Use the measuring device only for media against which the process-wetted materials are adequately resistant. Incorrect use Non-designated use can compromise safety. The manufacturer is not liable for damage caused by improper or non-designated use. LWARNING Danger of breakage due to corrosive or abrasive fluids! ‣ Verify the compatibility of the process fluid with the sensor material. ‣ Ensure the resistance of all fluid-wetted materials in the process. ‣ Keep within the specified pressure and temperature range. Residual risks LWARNING The electronics and the medium may cause the surfaces to heat up. This presents a burn hazard! ‣ For elevated fluid temperatures, ensure protection against contact to prevent burns. 2.3 Workplace safety For work on and with the device: ‣ Wear the required personal protective equipment according to federal/national regulations. For welding work on the piping: ‣ Do not ground the welding unit via the measuring device. Endress+Hauser Picomag IO-Link Basic safety instructions 2.4 Operational safety Risk of injury! ‣ Operate the device in proper technical condition and fail-safe condition only. ‣ The operator is responsible for interference-free operation of the device. 2.5 Product safety This measuring device is designed in accordance with good engineering practice to meet state-of-the-art safety requirements, has been tested, and left the factory in a condition in which it is safe to operate. It meets general safety standards and legal requirements. It also complies with the EU directives listed in the device-specific EU Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device. 2.6 IT security We only provide a warranty if the device is installed and used as described in the Operating Instructions. The device is equipped with security mechanisms to protect it against any inadvertent changes to the device settings. IT security measures in line with operators' security standards and designed to provide additional protection for the device and device data transfer must be implemented by the operators themselves. 2.7 Device-specific IT security 2.7.1 Access via the SmartBlue App Two access levels (user roles) are defined for the device: the Operator user role and the Maintenance user role. The Maintenance user role is the default setting. If a user-specific access code is not defined (in the Set access code parameter), the default setting 0000 continues to apply and the Maintenance user role is automatically enabled. The device's configuration data are not write-protected and can be edited at all times. If a user-specific access code has been defined (in the Set access code parameter), all the parameters are write-protected and the device is accessed with the Operator user role. The previously defined access code must first be entered again before the Maintenance user role is enabled and all the parameters can be write-accessed. 2.7.2 Access via Bluetooth® wireless technology Signal transmission via Bluetooth® wireless technology uses a cryptographic technique tested by the Fraunhofer Institute • The device is not visible via Bluetooth® wireless technology without the SmartBlue App. • Only one point-to-point connection is established between a sensor and a smartphone or tablet. • The Bluetooth® wireless technology interface can be disabled via SmartBlue. Endress+Hauser Incoming acceptance and product identification Picomag IO-Link Incoming acceptance and product identification 3.1 Incoming acceptance Are the order codes on the delivery note (1) and the product sticker (2) identical? A0028673 Are the goods undamaged? A0028673 A0028673 Do the nameplate data match the ordering information on the delivery note? Order code: Ser. no.: Ext. ord. cd.: Date: Is the CD-ROM with the Technical Documentation (depends on device version) and documents present? A0028673 • If one of the conditions is not satisfied, contact your Endress+Hauser Sales Center. • Depending on the device version, the CD-ROM might not be part of the delivery! The Technical Documentation is available via the Internet or via the Endress+Hauser Operations App, see the "Product identification" section . 3.2 Product identification The following options are available for identification of the measuring device: • The device label • Order code with breakdown of the device features on the delivery note • Enter the serial number on the device label in W@M Device Viewer (www.endress.com/deviceviewer): all the information about the measuring device is displayed. • Enter the serial number on the device label into the Endress+Hauser Operations App or scan the 2-D matrix code (QR code) on the measuring device with the Endress+Hauser Operations App: all the information about the measuring device is displayed. Endress+Hauser Picomag IO-Link Incoming acceptance and product identification 3.2.1 Symbol Symbols on measuring device Meaning WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. Reference to documentation Refers to the corresponding device documentation. Endress+Hauser Storage and transport Picomag IO-Link Storage and transport 4.1 Storage conditions Observe the following notes for storage: ‣ Store in the original packaging to ensure protection from shock. ‣ Store in a dry place. ‣ Do not store outdoors. Storage temperature→ 34 4.2 Transporting the product Transport the measuring device to the measuring point in the original packaging. Do not remove protective covers or caps installed on process connections. They prevent mechanical damage to the sealing surfaces and contamination in the measuring tube. 4.3 Packaging disposal All packaging materials are environmentally friendly and 100% recyclable: Carton in accordance with European Packaging Directive 94/62EC; recyclability is confirmed by the affixed RESY symbol. 10 Endress+Hauser Picomag IO-Link Installation Installation 5.1 Installation conditions 5.1.1 Mounting position Mounting location A0032998 Preferably install the sensor in an ascending pipe, and ensure a sufficient distance to the next pipe elbow: h ≥ 2 × DN Inlet and outlet runs Observe the following inlet and outlet runs to comply with accuracy specifications: ≥ 3 × DN ≥ 1 × DN A0032997 Installation dimensions: information on the dimensions and installed lengths of the device → 35 5.2 Mounting the measuring device LWARNING Burn hazard! If medium temperatures or ambient temperatures exceed 50 °C, areas of the housing can heat to over 65 °C. ‣ Safeguard the housing so that it cannot be touched accidentally. Endress+Hauser 11 Installation Picomag IO-Link 4 5 5 4 A0033002 12 Pipe Seal (not supplied) Adapter: available adapters → 33 Seal (included in delivery) Measuring device connection Endress+Hauser Picomag IO-Link Electrical connection Electrical connection 6.1 Connection conditions 6.1.1 Requirements for connecting cables National regulations and standards apply. Connecting cable M12 × 1 A-coded Conductor cross-section At least 0.12 mm2 (AWG26) Temperature range –10 to +80 °C (+14 to +176 °F) Degree of protection IP65/67 6.1.2 Pin assignment, device plug L+ OUT2 OUT1 L- A0033004 Endress+Hauser Socket Connector Pin Assignment Description L+ Supply voltage + (18 to 30 VDC/max. 3 W) Output 2 Output 2, can be configured independently of output 1 L- Supply voltage - Output 1 Output 1, can be configured independently of output 2 13 Electrical connection Picomag IO-Link Switch/pulse output configuration version Configurable switching behavior: pnp 1) npn 2) L+ L+ L- L- A0033005 L+ L- Socket Connector Supply voltage + Supply voltage - L+ L- The load is switched to high side L+. The maximum load current is 250 mA. The output is overloadresistant. 1) 2) A0033006 Socket Connector Supply voltage + Supply voltage - The load is switched to low side L-. The maximum load current is 250 mA. The output is overload-resistant. positive negative positive (high side switch) negative positive negative (low side switch) Current output configuration version L+ L- A0033007 1 L+ L- Current output, active, 4 to 20 mA Socket Connector Supply voltage + Supply voltage - The current flows from the output to L-. The maximum load may not exceed 500 Ω. A bigger load distorts the output signal. Voltage output configuration version L+ LA0033007 2 L+ L- 14 Voltage output, active, 2 to 10 V Socket Connector Supply voltage + Supply voltage - Endress+Hauser Picomag IO-Link Electrical connection The voltage from the output applies to L-. The load must be at least 500 Ω. The output is overload-resistant. Status input configuration version • 15 V (switch-on threshold) • 5 V (switch-off threshold) L+ = = LA0033008 3 L+ L- Status input Socket Connector Supply voltage + Supply voltage - Internal resistance: 7.5 Ω IO-Link configuration version Option only available for output 1 in the Output 1→ 22 submenu The measuring device has a Type 2 IO-Link communication interface with a second IO function on pin 2 and with a baud rate of 38 400. This requires an IO-Link-enabled module (IO-Link Master) for operation. The IO-Link communication interface allows direct access to the process and diagnostics data. 6.2 Connecting the measuring device NOTICE The measuring device may only be installed by properly trained technicians. ‣ Comply with national and international regulations regarding the installation of electrotechnical systems. ‣ Power supply according to EN 50178, SELV, PELV or Class 2. 1. De-energize the system. 2. Connect the measuring device via the connector. 3. A0033003 In the case of non-grounded pipes: The device must be grounded using the ground terminal accessory. Endress+Hauser 15 Electrical connection Picomag IO-Link 6.3 16 Post-connection check Are cables or the device undamaged (visual inspection)? Do the cables have adequate strain relief? Is the connector connected correctly? Does the supply voltage match the specifications on the measuring device? Is the pin assignment of the connector correct? Is the potential equalization established correctly? Endress+Hauser Picomag IO-Link Operation options Operation options 7.1 Access to the operating menu via the SmartBlue App The device can be operated and configured via the SmartBlue App. In this case, the connection is established via the Bluetooth® wireless technology interface. Supported functions • Device selection in Live List and access to the device (login) • Configuration of the device • Access to measured values, device status and diagnostics information The SmartBlue App is available for free download for Android devices (Google Playstore) and iOS devices (iTunes Apple Shop) : Endress+Hauser SmartBlue Directly to the app with the QR code: A0033202 System requirements • Devices with iOS: – iPhone 4S or higher, from iOS9.0 – iPad2 or higher, from iOS9.0 – iPod Touch 5th generation or higher, from iOS9.0 • Devices with Android: Android 4.4 KitKat or higher Download the SmartBlue App: 1. Install and start the SmartBlue App. A Live List shows all the devices available. The list displays the devices with the configured tag name. The default setting for the tag name is EH_DMA_XYZZ (XYZZ = the last 7 digits of the device serial number). 2. Select the device from the Live List. The Login dialog box opens. Logging in: 3. Enter the user name: admin. 4. Enter the initial password: serial number of the device. 5. Confirm your entry. The main menu opens. Navigate through the various items of information about the device: swipe the screen to the side. Endress+Hauser 17 System integration Picomag IO-Link System integration The measuring device has an IO-Link communication interface. The IO-Link interface allows direct access to process and diagnostics data and enables the user to configure the measuring device on the fly. Properties: • IO-Link Specification: Version 1.1 • IO-Link Smart Sensor Profile 2nd Edition • SIO mode: yes • Speed: COM2 (38.4 kBaud) • Minimum cycle time: depends on device and is defined by a number of factors including the process data to be transmitted. 10 ms • Process data width: depends on device and is defined by a number of factors including the process data to be transmitted. 80 bit • IO-Link data storage: yes • Block configuration: no More information on IO-Link is available at www.io-link.com 8.1 Overview of device description files Current version data for the device Firmware version 01.00.zz • On the title page of the Operating instructions • On the device label • Parameter Firmware version System → Device info → Firmware version Release date of firmware version 09.2017 --- Profile version • 1.1 • Smart Sensor Profile --- 8.2 Device master file In order to integrate field devices into a digital communication system, the IO-Link system needs a description of the device parameters, such as output data, input data, data format, data volume and supported transmission rate. These data are available in the device master file (IODD 1)) which is provided to the IO-Link Master via generic modules when the communication system is commissioned. The IODD can be downloaded as follows: • Endress+Hauser: www.endress.com • IODDfinder: ioddfinder.io-link.com 1) 18 IO Device Description Endress+Hauser Picomag IO-Link Commissioning Commissioning 9.1 Switching ON the measuring device Once the supply voltage has been switched on, the measuring device adopts the normal mode after a maximum of 5 s. During the start-up phase, the outputs are in the same state as the measuring device in the switched-off state. 9.2 Configuring the measuring device Overview of the operating menu Application ▸ Measured values → 27 ▸ System units → 21 ▸ Process ▸ Sensor → 21 ▸ Output 1 → 22 ▸ Output 2 → 22 ▸ Device info → 32 ▸ Display → 20 ▸ Bluetooth configuration → 28 ▸ Administration → 28 ▸ Actual diagnostics → 32 ▸ Simulation 1 → 26 System Diagnostics Endress+Hauser 19 Commissioning Picomag IO-Link 9.2.1 Configuring the display The Display submenu contains all the parameters that can be configured for the configuration of the onsite display. Navigation Menu: "System" → Display Parameter overview with brief description Parameter Format display Description Select how measured values are shown on the display. Rotation display Select local display rotation. Selection/input Factory setting Display value 1st line + display value 2nd line: • Volume flow + temperature • Volume flow + totalizer • Temperature + totalizer Volume flow + temperature • Auto (automatic) • The display rotates automatically depending on the installation position Auto • 0° • Can be read in the horizontal installation position with flow from left to right A0033013 • 90° • Can be read in the vertical installation position with flow from bottom to top A0033014 • 180° • Can be read in the horizontal installation position with flow from right to left A0033015 • 270° • Can be read in the vertical installation position with flow from top to bottom A0033016 Backlight 20 Set the intensity of the backlighting. 0 to 100 % 50 % Endress+Hauser Picomag IO-Link Commissioning 9.2.2 Configuring system units In the System units submenu, you can configure the units of all measured values. Navigation Menu: "Application" → System units Parameter overview with brief description Parameter Description Options Factory setting Volume flow unit Select volume flow unit. • l/s, m³/h, l/min • gal/min (us) l/min Volume unit Select volume unit. • ml, l, m³ • fl. oz (us), gal (us) ml Temperature unit Select temperature unit. • °C • °F °C Totalizer unit Select totalizer unit. • • • • m³ 9.2.3 l, m³ 1 000 l, 1 000 m3 fl. oz (us), gal (us) 1 000 gal (us) Setting the installation direction and measurement The Sensor submenu contains parameters for specific settings of the measuring device. Navigation Menu: "Application" → Sensor Parameter overview with brief description Parameter Description Selection/input Factory setting Installation direction Select the installation direction. • Flow in arrow direction (forwards) Positive flow measurement in the direction of the arrow. • Flow against arrow direction (backwards) Positive flow measurement in the opposite direction of the arrow. Flow in arrow direction (forwards) On value Enter the on value for low flow cut off. Positive floating point number Depends on the nominal diameter: DN 15 (½"): 0.4 l/min (0.1 gal/min) DN 20 (¾"): 0.75 l/min (0.2 gal/min) DN 25 (1"): 1.2 l/min (0.3 gal/min) DN 50 (2"): 5.0 l/min (1.3 gal/min) flow measured value that is less than the value of the on Avalue forces the display to zero. In the event of plant downtime, this prevents the totalizer from continuing to totalize even though there is no flow. Damping Enter the time constant for damping the flow measured value. Endress+Hauser 0 to 10 s 0s 21 Commissioning Picomag IO-Link 9.2.4 Configuring the IO modules The measuring device has two signal inputs or signal outputs that can be configured independently of one another: • Current output→ 22 • Pulse output→ 22 • Switch output→ 23 • Voltage output→ 24 • Status input → 25 Navigation Menu: "Application" → Output 1 Menu: "Application" → Output 2 Parameter overview with brief description Parameter Description Options Factory setting I/O module 1 type Select the operating mode of output 1. • • • • • • • Pulse output Current output Switch output Voltage output Digital input IO-Link Off IO-Link I/O module 2 type Select the operating mode of output 2. • • • • • • Pulse output Current output Switch output Voltage output Digital input Off Switch output Configuring the current output The Current output submenu contains all the parameters that must be configured for the configuration of the current output. The output is used to output process variables by analog means in the form of a 4-20 mA current. Navigation Menu: "Application" → Output 1 → Current output Menu: "Application" → Output 2 → Current output Parameter overview with brief description Parameter Description Selection/input Factory setting Assign current output Select process variable for current output. • Off • Volume flow • Temperature Volume flow 4 mA value Enter 4 mA value. Floating point number with sign 0 l/min 20 mA value Enter 20 mA value. Floating point number with sign Depends on the nominal diameter: DN 15 (½"): 25 l/min (6.6 gal/min) DN 20 (¾"): 50 l/min (13.2 gal/min) DN 25 (1"): 100 l/min (26.4 gal/min) DN 50 (2"): 750 l/min (198.1 gal/min) Configuring the pulse output The Pulse output submenu contains all the parameters that must be configured for the configuration of the pulse output. Navigation 22 Endress+Hauser Picomag IO-Link Commissioning Menu: "Application" → Output 1 → Pulse output Menu: "Application" → Output 2→ Pulse output Parameter overview with brief description Parameter Value per pulse Description Enter the value for the pulse output. Entry Floating point number with sign Factory setting Depends on the nominal diameter: DN 15 (½"): 0.5 l/min (0.1 gal/min) DN 20 (¾"): 1.0 l/min (0.3 gal/min) DN 25 (1"): 2.0 l/min (0.5 gal/min) DN 50 (2"): 10.0 l/min (2.6 gal/min) The current pulse repetition frequency is calculated from the current flow and the configured pulse value: Pulse repetition frequency = flow/pulse value Example • Flow: 300 l/min (79.25 gal/min) • Pulse value: 0.001 l • Pulse repetition frequency = 5 000 Pulse/s • The maximum pulse repetition frequency is 10 kHz. The Pulse output only outputs positive flow components in the set installation direction. Negative flow components are ignored and not balanced. Configuring the switch output The Switch output submenu contains all the parameters that must be configured for the configuration of the switch output. Navigation Menu: "Application" → Output 1 → Switch output Menu: "Application" → Output 2 → Switch output Parameter overview with brief description Parameter Polarity Switch output function Description Select the switching behavior. Selection/input • NPN (low-side-switch) Switches load to low side to L• PNP (high-side-switch) Switches load to high side to L+ Factory setting PNP (high-side-switch) • Diagnostic behavior Diagnostic behavior The output switches when an event with the status signal F occurs • Off The switch output is permanently switched off (open, non-conductive). • On The switch output is permanently switched on (closed, conductive). • Limit volume flow Indicates if a specified limit value has been reached for the process variable. • Limit temperature Indicates if a specified limit value has been reached for the process variable. • Range volume flow • Range temperature • Empty pipe detection Output switches on when empty pipe detection is active. Switch-on value Enter the measured value Floating point number with sign for the switch-on value. Country-specific: • 1 000 m³/h • 1 000 gal/min (us) Switch-off value Enter the measured value Floating point number with sign for the switch-off value. Country-specific: • 1 000 m³/h • 1 000 gal/min (us) Endress+Hauser 23 Commissioning Picomag IO-Link Hysteresis switched on Hysteresis switched off Q/T Q/T 2.1 1.1 2.2 1.2 A0034163 1.1 1.2 Input variables Switch output Switch-on point Switch-off value Hysteresis A0034164 2.1 2.2 Range switched on Input variables Switch output Switch-on point Switch-off value Hysteresis Range switched off Q/T Q/T 4.1 3.1 4.2 3.2 A0034165 3.1 3.2 Input variables Switch output On-value (lower range limit) Off-value (upper range limit) Window A0034166 4.1 4.2 Input variables Switch output On-value (lower range limit) Off-value (upper range limit) Window Configuring the voltage output The Voltage output submenu contains all the parameters that must be configured for the configuration of the voltage output. Navigation Menu: "Application" → Output 1 → Voltage output Menu: "Application" → Output 2 → Voltage output Parameter overview with brief description Parameter Description Selection/input Factory setting Assign voltage output Select process variable for voltage output. • Off • Volume flow • Temperature Volume flow 2 V value Enter the lower-range value. Floating point number with sign 0 l/min 10 V value Enter the upper-range value. Floating point number with sign Depends on the nominal diameter: DN 15 (½"): 25 l/min (6.6 gal/min) DN 20 (¾"): 50 l/min (13.2 gal/min) DN 25 (1"): 100 l/min (26.4 gal/min) DN 50 (2"): 750 l/min (198.1 gal/min) 24 Endress+Hauser Picomag IO-Link Commissioning Unidirectional flow measurement (Q) mA / V 20 10 16 12 6 A=0 A0032995 Lower-range value = 0 Upper-range value Flow • Current I or voltage U are interpolated linearly between the lower-range value (A) and upper-range value (B). • The output range ends at 20.5 mA or 10.5 V. Bidirectional flow measurement (Q) or temperature measurement (T) mA / V 20 10 16 12 6 A0032996 Lower value Upper-range value Flow • Current I or voltage U are interpolated linearly between the lower-range value (A) and upper-range value (B). • Rather than having a hard upper and lower limit, the output range ends at 20.5 mA or 10.5 V at the top end, and at 3.8 mA or 1.9 V at the bottom end. Configuring the status input The Digital input submenu contains all the parameters that must be configured for the configuration of the digital input. The input is used to control an action with an external voltage signal. The minimum pulse duration is 100 ms. Navigation Menu: "Application" → Output 1 → Digital input Endress+Hauser 25 Commissioning Picomag IO-Link Menu: "Application" → Output 2 → Digital input Parameter overview with brief description Parameter Description Options Factory setting Active level Select the switching behavior of the digital input. • High Input reacts to high level • Low Input reacts to low level High Assign status input Select process variable for status input. • Off • Reset totalizer Resets the totalizer • Flow override – Flow measured value = 0 – Does not affect the temperature measurement Reset totalizer 9.2.5 Simulation The Simulation submenu enables you to simulate, without a real flow situation, different process variables in the process and the device alarm behavior and to verify downstream signal chains (switching of valves or closed-control loops). Navigation Menu: "Diagnostics" → Simulation 1 Parameter overview with brief description Parameter Simulation process variable Description Activate the simulation of process variables. Factory setting Selection/input • Off Simulation is deactivated. • On Simulation is activated. Off the simulation again once the test has Deactivate been performed. Volume flow value Enter the value for volume flow simulation. Positive floating point number – Temperature value Enter the value for temperature simulation. Positive floating point number – 26 Endress+Hauser Picomag IO-Link Operation 10 Operation 10.1 Reading measured values You can read all measured values using the Measured values submenu. Navigation Menu: "Application" → Measured values Parameter overview with brief description Parameter Description Display/options Factory setting Volume flow Displays the volume flow currently measured. Floating point number with sign – Temperature Displays the temperature currently measured. Floating point number with sign – Totalizer Displays the current totalizer counter value. The totalizer continuously totalizes only positive flow measured values in the set flow direction. Negative components are not counted. Floating point number with sign – Reset totalizer Reset the totalizer. Endress+Hauser • Cancel The totalizer is not reset. • Reset + totalize The totalizer is reset. Cancel 27 Operation Picomag IO-Link 10.2 Configuring Bluetooth The Bluetooth configuration submenu contains all the parameters to configure the Bluetooth connection. Navigation Menu: "System" → Bluetooth configuration Parameter overview with brief description Parameter Bluetooth Description Options Factory setting Enable or disable the Bluetooth® wireless technology interface. • Disable Enable – Disable the interface. – The connection to the measuring device is torn down. If the interface is disabled, it can only be re-enabled by • Enable tapping the device. – Enable the interface. – The connection to the measuring device is established. 10.3 Administration The Administration submenu contains all the parameters that can be used for the administration of the device. Navigation Menu: "System" → Administration Parameter overview with brief description Parameter Description Entry/selection/display Factory setting Set access code Enter a user-specific access code to restrict write access to parameters. Max. 4-digit character string comprising numbers, letters and special characters 0000 Enter access code Enter the access code. Restrict write access to parameters in order to protect the device configuration from unauthorized modification. Max. 4-digit character string comprising numbers, letters and special characters 0000 Device reset Reset the entire device configuration or some of the configuration to a defined state. • Cancel • To factory defaults • Restart device Cancel • Operator • Maintenance Maintenance Access status tooling Displays the access status. 28 Endress+Hauser Picomag IO-Link Diagnostics and troubleshooting 11 Diagnostics and troubleshooting 11.1 General troubleshooting For local display Error Local display dark and no output signals Possible causes Supply voltage does not match the value indicated on the nameplate. Solution Apply the correct supply voltage → 34. The polarity of the supply voltage is Correct the polarity. wrong. The connecting cables are not connected correctly. Check the cable connection and correct if necessary. For output signals Error Possible causes Solution Device shows correct value on local Configuration error display, but signal output is incorrect, though in the valid range. Check and correct the parameter configuration. Device measures incorrectly. 1. Check and correct parameter configuration. 2. Observe limit values specified in the "Technical Data". Configuration error or device is operated outside the application. For access Error Possible causes Solution No connection established via Bluetooth Bluetooth communication is disabled 1. Check whether the Bluetooth logo is visible on the local display or not. 2. Re-enable Bluetooth communication by tapping the device. No communication with device via SmartBlue App No Bluetooth connection Enable Bluetooth function on smartphone or tablet. The device is already connected with another smartphone/tablet. Endress+Hauser Login via SmartBlue App not possible Device is being put into operation for the first time Enter initial password (device serial number) and change. Device cannot be operated via SmartBlue App Incorrect password entered Enter correct password. Password forgotten Contact Endress+Hauser Service. 29 Diagnostics and troubleshooting Picomag IO-Link 11.2 Diagnostic information on local display 11.2.1 Diagnostic message Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display. Diagnostic message Alarm Function check Xxxxxxx Warning Xxxxxxx Xxxxxxx F180 C446 S962 T E M P.C I R C .F A I L . I/O 1 OVERLOAD E M P TY P I P E A0033011 A0033010 A0033009 If two or more diagnostic events are pending simultaneously, only the message of the diagnostic event with the highest priority is shown. Status signals The status signals provide information on the state and reliability of the device by categorizing the cause of the diagnostic information (diagnostic event). The status signals are categorized according to VDI/VDE 2650 and NAMUR Recommendation NE 107: F = Failure, C = Function Check, S = Out of Specification, M = Maintenance Required Symbol Meaning Failure An operating error has occurred. The measured value is no longer valid. Function check The device is in simulation mode. Out of specification The device is being operated: • Outside its technical specification limits (e.g. outside the process temperature range) • Outside of the configuration carried out by the user (e.g. maximum flow in parameter 20 mA value) Diagnostic behavior Diagnostic message Meaning Alarm • Measurement is interrupted. • Signal outputs and totalizers assume the defined alarm condition. • A diagnostic message is generated. Function check Process measured values are simulated to test the outputs/wiring. 30 Warning • • • • Measurement is resumed. Measuring operation with limited accuracy The signal outputs and totalizers are not affected. A diagnostic message is generated. Endress+Hauser Picomag IO-Link Diagnostics and troubleshooting Diagnostics behavior of outputs Output Diagnostic behavior Switch output • Setting for reporting events with the status signal F • Switch output is switched on if an event occurs • No further response to events with other status signals Pulse output • Pulse output stops if events with the status signal F occur • No further response to events with other status signals Totalizer • Totalizing stops if events with the status signal F occur • No further response to events with other status signals Current output • 3.5 mA output to report events with the status signal F • No further response to events with other status signals Voltage output • 1.75 V output to report events with the status signal F • No further response to events with other status signals IO-Link • All events reported to the Master • Events read and processed further by the Master 11.3 Diagnostic event Endress+Hauser Overview of diagnostic events Status signal [exfactory] Event text Reason Remedial measures 181 Coil. circ. fail. Coil/frequency failure Coil current PWM outside tolerance range Replace the measuring device. 180 Temp. circ. fail. Temperature sensor open circuit/shortcircuit Replace the measuring device. 201 Device fail. No communication to ADC/Nordic/BMA Replace the measuring device. 283 Memory fail. CRC failure Reset to factory settings. 446 I/O 1 overload Overload at output 1 Increase load impedance. 447 I/O 2 overload Overload at output 2 Increase load impedance. 485 Simulation act. Measured value simulation active (via remote configuration) – 453 Flow override Flow override active (via – auxiliary input) 441 I-Out 1 range I-output 1 at range limit Adjust parameter or process. 444 U-Out 1 range U-output 1 at range limit Adjust parameter or process. 443 P-Out 1 range P-output 1 at range limit Adjust parameter or process. 442 I-Out 2 range I-output 2 at range limit Adjust parameter or process. 445 U-Out 2 range U-output 2 at range limit Adjust parameter or process. 448 P-Out 2 range P-output 2 at range limit Adjust parameter or process. 962 Empty pipe Pipe is completely or partially empty Adjust the process. 31 Diagnostics and troubleshooting Picomag IO-Link Diagnostic event Event text Reason Status signal [exfactory] Remedial measures 834 Temperat. range Medium temperature outside the permitted range Adjust the process. 841 Flow range Flow rate outside the permitted range Adjust the process. 11.4 Pending diagnostic events Navigation Menu: "Diagnostics" → Diagnostics Parameter overview with brief description Parameter Actual diagnostic Prerequisite Description A diagnostic event has occurred. Display Displays the current diagnostic event along with the diagnostic information. two or more messages occur simultaneously, the message with the Ifhighest priority is shown on the display. 11.5 Symbol for diagnostic behavior, diagnostic code and short message. Device information The Device info submenu contains all parameters that display different information for device identification. Navigation Menu: "System" → Device info Parameter overview with brief description Parameter Description Display Device name Displays the name of the measuring device. Picomag Device tag Shows name of measuring point. Max. 32 characters, such as letters, numbers or special characters (e.g. @, %, /). Serial number Displays the serial number of the measuring device. Max. 11-digit character string comprising letters and numbers. Firmware version Displays the device firmware version installed. Extended order code Displays the extended order code. 11.6 Release date 09.2017 32 Character string in the format xx.yy.zz Character string composed of letters, numbers and certain punctuation marks (e.g. /). Firmware history Firmware version 01.00.zz Firmware changes Original firmware Documentation type Operating Instructions Documentation BA01697D/06/EN/01.17 Endress+Hauser Picomag IO-Link Accessories 12 Accessories Various accessories, which can be ordered with the device or subsequently from Endress +Hauser, are available for the device. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com. Endress+Hauser 33 Technical data Picomag IO-Link 13 Technical data 13.1 Input Measured values • Volume flow • Temperature • Totalizer Measuring range (upper-range value E) DN 15 (½"): 25 l/min (6.6 gal/min) DN 20 (¾"): 50 l/min (13.2 gal/min) DN 25 (1"): 100 l/min (26.4 gal/min) DN 50 (2"):750 l/min (198.1 gal/min) 13.2 Output Output Max. load Current output 500 Ω The load may not be any greater Voltage output 500 Ω The load resistance may not any smaller Digital output (SmartBlue App) Bluetooth® wireless technology The device has a Bluetooth® wireless technology interface and can be operated and configured via the SmartBlue App. • The range under reference conditions is 10 m (33 ft) • Incorrect operation by unauthorized persons is prevented by means of encrypted communication and password encryption. • The Bluetooth® wireless technology interface can be deactivated. Signal on alarm 13.3 • Status signal (as per NAMUR Recommendation NE 107) • Plain text display with remedial action Power supply Supply voltage range 18 to 30 VDC (SELV, PELV, Class 2) Power consumption Max. 3 W (excluding outputs IO1 and IO2) 13.4 Performance characteristics Volume flow measurement Maximum measured error ±2 % o.r. ±0.5 % o.f.s. Repeatability ±0.2 % o.r. (95% confidence interval, measuring time 30 s) Response time The response time depends on the configuration (damping). Medium temperature measurement Maximum measured error ±2.5 °C Repeatability ±0.5 °C (95% confidence interval, measuring time 30 s) 13.5 Installation → 11 13.6 34 Environment Ambient temperature range –10 to +60 °C (+14 to +140 °F) Storage temperature –25 to +85 °C (–13 to +185 °F) Endress+Hauser Picomag IO-Link Technical data Degree of protection IP65/67 Shock resistance 20 g (11 ms) as per IEC/EN60068-2-27 Vibration resistance Acceleration up to 5 g (10 to 2 000 Hz) as per IEC/EN60068-2-6 Electromagnetic compatibility (EMC) In accordance with IEC/EN61326 and/or IEC/EN55011 (Class A) 13.7 Process Medium temperature range –10 to +70 °C (+14 to +158 °F) Medium properties Liquid, conductivity > 20 µS/cm Pressure Max. 16 barrel 13.8 Mechanical construction A0033012 Dimensions in SI units DN [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 15, 20, 25 110 73 40.5 69.5 M12 × 1 43 ½" ¾" 1" 56 56 50 200 113 80 120 M12 × 1 58 2" 86 86 Dimensions in US units DN [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] ½, ¾, 1 4.33 2.87 1.59 2.74 M12 × 1 1.69 ½" ¾" 1" 2.20 2.20 7.87 4.45 3.15 4.72 M12 × 1 2.28 2" 3.39 3.39 Weight in SI units Endress+Hauser DN [mm] Weight [kg] 15 0.34 20 0.35 25 0.36 50 1.55 35 Technical data Picomag IO-Link Weight in US units DN [in] Weight [lbs] ½" 0.75 ¾" 0.77 1" 0.79 2" 3.42 Materials Component Material Measuring tube PEEK Electrodes, temperature sensor 1.4404/316L Process connection 1.4404/316L Housing 1.4404/316L Seal FKM Display window Polycarbonate 13.9 Onsite display Operability The device has an onsite display: Xxxxxxx 28.56 23.6 l / min °C A0032991 Tag name (configurable) Measured variable 1 (configurable), with sign Measured variable 2 (configurable), with sign Active Bluetooth connection Active I/O-Link connection Device status Display element A maximum of 2 readings from the 3 measured variables (volume flow, temperature, totalizer) can be displayed Remote operation Via Bluetooth® wireless technology Digital communication Via IO-Link 13.10 Certificates and approvals 36 Endress+Hauser Picomag IO-Link CE mark Technical data The measuring system is in conformity with the statutory requirements of the applicable EU Directives. These are listed in the corresponding EU Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. Radio approval The measuring device has radio approval. For detailed information on the radio approval, see the Appendix → 38 Pressure Equipment Directive Devices not bearing this marking (PED) are designed and manufactured according to good engineering practice. They meet the requirements of Art. 4, Par. 3 of the Pressure Equipment Directive 2014/68/EU. The range of application is indicated in tables 6 to 9 in Annex II of the Pressure Equipment Directive 2014/68/EC. CULUS The measuring device is UL-listed. listing Endress+Hauser 37 Appendix Picomag IO-Link 14 Appendix 14.1 Radio approvals 14.1.1 Europe This device meets the requirements of the Telecommunications Directive RED 2014/53/EU: • EN 300 328 V2.1.1 • EN 301 489-1 V1.9.2 • EN 301 489-17 V2.2.1 • EN 62311: 2008 14.1.2 Canada and USA English This device complies with Part 15 of the FCC Rules and with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by Endress+Hauser Flowtec AG may void the user's authorization to operate this equipment. Français Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : • L'appareil ne doit pas produire de brouillage, et • L'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Les changements ou modifications apportées à cet appareil non expressément approuvée par Endress+Hauser Flowtec AG peut annuler l'autorisation de l'utilisateur d'opérer cet appareil. 14.1.3 Other countries Other national approvals are available on request. 38 Endress+Hauser Picomag IO-Link Index Index About this document . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Application Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Basic safety instructions . . . . . . . . . . . . . . . . . . . . . . . 6 Bidirectional flow measurement (Q) or temperature measurement (T) . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7, 37 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Configuring system units . . . . . . . . . . . . . . . . . . . . . . 21 Configuring the current output . . . . . . . . . . . . . . . . . 22 Configuring the display . . . . . . . . . . . . . . . . . . . . . . . 20 Configuring the IO modules . . . . . . . . . . . . . . . . . . . . 22 Configuring the measuring device . . . . . . . . . . . . . . . 19 Configuring the pulse output . . . . . . . . . . . . . . . . . . . 22 Configuring the status input . . . . . . . . . . . . . . . . . . . 25 Configuring the voltage output . . . . . . . . . . . . . . . . . 24 Connecting the measuring device . . . . . . . . . . . . . . . . 15 Connection conditions . . . . . . . . . . . . . . . . . . . . . . . . 13 Current output configuration version . . . . . . . . . . . . . 14 Current version data for the device . . . . . . . . . . . . . . . 18 Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . 7 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Device information . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Device master file . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Diagnostic behavior . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Diagnostic information on local display . . . . . . . . . . . 30 Diagnostic message . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Diagnostics and troubleshooting . . . . . . . . . . . . . . . . 29 Dimensions in SI units . . . . . . . . . . . . . . . . . . . . . . . . 35 Dimensions in US units . . . . . . . . . . . . . . . . . . . . . . . 35 Document function . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . 13 Field of application Residual risks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Firmware history . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Identifying the measuring device . . . . . . . . . . . . . . . . . 8 Incoming acceptance . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . 11 Inspection Received goods . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Endress+Hauser Installation conditions . . . . . . . . . . . . . . . . . . . . . . . . 11 IO-Link configuration version . . . . . . . . . . . . . . . . . . 15 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting position . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting the measuring device . . . . . . . . . . . . . . . . . 36 11 11 11 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Operation options . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 SmartBlue App . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Operational safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Overview of device description files . . . . . . . . . . . . . . 18 Overview of diagnostic events . . . . . . . . . . . . . . . . . . 31 Overview of the operating menu . . . . . . . . . . . . . . . . 19 Packaging disposal . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pending diagnostic events . . . . . . . . . . . . . . . . . . . . . 32 Pin assignment, device plug . . . . . . . . . . . . . . . . . . . . 13 Post-connection check . . . . . . . . . . . . . . . . . . . . . . . . 16 Pressure Equipment Directive . . . . . . . . . . . . . . . . . . 37 Product safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Radio approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Radio approvals . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Reading measured values . . . . . . . . . . . . . . . . . . . . . . 27 Registered trademarks . . . . . . . . . . . . . . . . . . . . . . . . . 5 Requirements for connecting cables . . . . . . . . . . . . . . 13 Requirements for personnel . . . . . . . . . . . . . . . . . . . . . 6 Setting the installation direction and measurement . . 21 Status input configuration version . . . . . . . . . . . . . . . 15 Status signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Storage conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . 10 Switch/pulse output configuration version . . . . . . . . . 14 Switching ON the measuring device . . . . . . . . . . . . . . 19 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 System integration . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Certificates and approvals . . . . . . . . . . . . . . . . . . . Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical construction . . . . . . . . . . . . . . . . . . . . Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Performance characteristics . . . . . . . . . . . . . . . . . Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 36 34 34 34 35 36 34 34 34 35 39 Index Picomag IO-Link Temperature range Storage temperature . . . . . . . . . . . . . . . . . . . . . . . 10 Tools Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Transporting the measuring device . . . . . . . . . . . . . . 10 Troubleshooting General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Unidirectional flow measurement (Q) . . . . . . . . . . . . 25 Using measuring device Borderline cases . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Incorrect use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Voltage output configuration version . . . . . . . . . . . . . 14 W@M Device Viewer . . . . . . . . . . . . . . . . . . . . . . . . . 8 Weight Transport (notes) . . . . . . . . . . . . . . . . . . . . . . . . . 10 Weight in SI units . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Weight in US units . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Workplace safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 40 Endress+Hauser www.addresses.endress.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : 06 Create Date : 2017:09:26 09:56:55+01:00 Keywords : Operating, Instructions;, Picomag;, Electromagnetic, flowmeter Modify Date : 2017:09:26 15:26:12+02:00 Subject : Electromagnetic flowmeter Language : EN XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : 06 Description : Electromagnetic flowmeter Title : Picomag IO-Link Creator Tool : AH XSL Formatter V6.2 MR13 for Windows (x64) : 6.2.15.22885 (2015/12/14 12:50JST) Metadata Date : 2017:09:26 15:26:12+02:00 Producer : Antenna House PDF Output Library 6.2.735 (Windows (x64)) Trapped : False Document ID : uuid:c8f8849e-10e4-4995-8bb9-04fa2f6f1285 Instance ID : uuid:9d70eaf5-5310-4e56-8889-b0c2f1d564d6 Page Mode : UseOutlines Page Count : 44EXIF Metadata provided by EXIF.tools