Enlighted SU5E SU-5E Micro Sensor User Manual PowerPoint Presentation

Enlighted, Inc. SU-5E Micro Sensor PowerPoint Presentation

User Manual

Page 5 Page 6 93-02056-01 Rev02  Page 1TechnicalSupportFor questions regarding theinstallation or operation of thisproduct,contact EnlightedTechnical Support: support@enlightedinc.comCompany Contact InformationLocation: 930 Benecia Ave, Sunnyvale, CA 94085Phone: +1.650.964.1094 Web: enlightedinc.comFCC and Industry Canada Compliance InformationThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.This device complieswith Part 15 of the FCC Rules and Industry Canadalicense-exempt RSS standard(s). Operation is subjectto the following two conditions:•this devicemay not cause harmful interference, AND•this device must accept anyinterference received, including interferencethat may cause undesiredoperation.Changes or modifications not expressly approved by Enlighted Inc. could void the user's authority to operate the equipment.Le présent appareil est conforme aux CNR d'Industrie Canada applicablesaux appareils radio exempts de licence.L'exploitationest autoriséeauxdeux conditions suivantes:•l'appareil ne doit pas produire de brouillage,ET•l'utilisateur de l'appareildoitaccepter tout brouillage radioélectriquesubi,même si le brouillage est susceptible d'en compromettre lefonctionnement.CEThis device complies with the essential requirements and other relevant requirements of the R&TTE Directive (1999/5/EC). The equipment is Class 1 radio equipment which can be placed on the market and be put into service without restrictions in accordance with article 1(3) of Commission Decision 2000/299/EC (Version July 2014).Copyright ©2017Enlighted Inc. All rights reserved.All other brand or product names are trademarks oftheir respective companies or organizations.Micro Sensor (SU-5E)Installation InstructionsModel No. : SU-5E-01FCC ID: AQQ-SU5EIC: 10138A-SU5EMicro Sensor and Carrier Shipped Components•Enlighted Micro Sensor  Supplemental Components•Enlighted Sensor Cable•Enlighted Control UnitTools you may Need•7/8” Drill bit  (1/2” knock out trade size)•Hand drillLED Status Description/SolutionLED not on Check power and wiringGreen blinking Sensor commissioned and workingRed blinking Sensor not commissionedRed solid Faulty sensor –replace sensorGreen solid Sensor installed, initialized, and uncommissioned –waiting for discovery.Blue solid Sensor received a request to identify itself  LED DescriptionStep 1:Connect the RJ12 end of the sensor cable to the Control Unit (CU). For wiring connections from the Control Unit to the sensor, refer to the Control Unit Installation Guide. Connecting the Sensor Cable to the Control UnitStep 2: Energize the luminaire and confirm that the green LED is solid.  R005-101515
Page 2 Page 3 Page 4Tile Mount Sensor InstallationFixture Mount Sensor InstallationCautionInstallation and maintenance must be performed by a qualifiedelectrician in accordance with local, state, and nationalelectrical codes (NEC) and requirements.Step 1: De-energize the luminaire.Step 3: Insert the fixture carrier through the hole in the fixture.Step 2: Determine the location for the sensor in the fixture and cut a ½ inch (7/8” diameter) knockout in the fixture. Note: For fixture mounting, use the fixture carrier and nut that is shipped with the sensor.Step 3: Insert the tile carrier through the hole into the tile. Step 4: Thread the plain end of the nut from behind the tile to secure the carrier.  Step 1: De-energize the luminaire.Step 4: From behind the fixture, align the tabs of the nut with the keys on the fixture carrier.  Step 2: Make a 7/8th diameter hole in the ceiling tile. Step 5: Slide the tabs of the nut along the keys of the carrier to fasten the carrier. If the tile is thicker than normal, flip the nut and thread the ribbed end of the nut to secure the carrier. Step 8: Guiding the wire from above, push the sensor into the carrier until it securely clicks into the carrier.Step 6: Insert the 8-pin end of the sensor cable through the carrier.  Step 10: See section Connecting the Sensor Cable to the Control Unit on Page 5.Step 7: Connect the 8-pin connector to the sensor. Note: Do not pull the cable forcefully as this might damage the cable or connector.Step 5: Insert the 8-pin end of the sensor cable through the carrier.  Step 6: Connect the 8-pin connector to the sensor. Step 7: Guiding the wire from above, push the sensor into the carrier until it securely clicks into the carrier.Fixture Carrier  NutTabsKeysTile Carrier  NutNote: For tile mounting, use the tile carrier and nut that is shipped with the sensor.Note: Do not pull the cable forcefully as this might damage the cable or connector.Step 8: Leave four inches of slack cable in the sequence loop to avoid pinching of the cable and to bring the sensor down if it needs to be replaced.Step 9: Leave four inches of slack cable in the sequence loop to avoid pinching of the cable and to bring the sensor down if it needs to be replaced.Step 9: See section Connecting the Sensor Cable to the Control Unit on Page 5.

Navigation menu