Everspring Industry Co SR102 PIR Sensor Lantern Transmitter User Manual

Everspring Industry Co Ltd PIR Sensor Lantern Transmitter

Users Manual

Download: Everspring Industry Co SR102 PIR Sensor Lantern Transmitter User Manual
Mirror Download [FCC.gov]Everspring Industry Co SR102 PIR Sensor Lantern Transmitter User Manual
Document ID692529
Application IDLFts5aceR0PRReA7JI5jIg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize46.93kB (586652 bits)
Date Submitted2006-08-11 00:00:00
Date Available2006-08-11 00:00:00
Creation Date2006-07-14 16:32:18
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2006-07-14 16:49:11
Document TitleMicrosoft Word - 使用手冊.DOC
Document CreatorPScript5.dll Version 5.2.2
Document Author: Elaine

ID codes, every of which is controllable to numerous receivers.
SR102 REMOTE TRANSMITTER
1. Setting the house code slide switch to “A” can operate EZ alarm (SE131).
The Remote Transmitter is designed to control a series of O-net products, such
as EZ Alarm (SE131), On/Off Receiver (AN121, B410N) and Dimmer Receiver
(AD121, B410D), serving as a multipurpose remote controller. It is equipped with
7 sets of ID codes, therefore, each set of them is capable of controlling limitless
receivers.
“A”
House Code Position
Button
No. of ID
ID1
ID1
ID1
ID1
When switching to the “A” position which is situated in the orange background of
plate, simply follow its orange track for operating
(instant arm),
(delay
arm),
(chime) and
(disarm) modes.
LOADING THE BATTERY
1. Remove the battery cover. Fit the 3V Lithium battery in the compartment
provided with +v terminal facing upwardly. (Fig. 1)
2. Setting the house code slide switch to “B”, “C” or “D” position can take control
of On/Off Receiver (AN121, B410N), Dimmer Receiver (AD121, B410D) and
Lantern Receiver (ED102).
House Code Position
st
1 . set of On, Off button
nd
2 set of On, Off button
“B”
ID2
ID3
“C”
ID4
ID5
“D”
ID6
ID7
4 buttons are divided into two sets, consisting of one pc each of On and Off
button. (Fig. 2)
Fig. 1
2. By pressing any key, the red LED will illuminate, which implies that the
battery has been inserted properly.
1st. set
2nd. set
3. Replace the battery cover.
SETTING THE HOUSE CODE
House
code
slide
switch
The Transmitter incorporates 4 buttons and a 4-position house code slide switch.
The 4-position house code slide switch ranges from A to D. (Fig. 2) When
controlling EZ alarm (SE131), the house code slide switch has to be set in “A”
position, while “B”, “C” and “D” positions are designed for use with On/Off
Receiver (AN121, B410N), Dimmer Receiver (AD121, B410D), Lantern Receiver
(ED102) and forthcoming O-net series products.
Fig. 2
Fig. 3
Note: Write down each designated lighting fixture in each group by adopting the
4-position house code slide switch coupled with 4 buttons may formulate 7 sets of
sticker affixed on the rear cover. (Fig. 3)
EMITTING THE ID CODE
In order to communicate with the EZ Alarm (SE131), ON/OFF Receiver
(AN121,B410N) and Dimmer Receiver (AD121,B410D), it is essential that the
same ID code is used between the Receiver and Transmitter.
Remote’s
operating status
Remote’s RF
transmission
On/Off Receiver’s
(AN121, B410N)
Operating status
Set the Receiver to the ID code learning mode. Press and hold the “OFF or
button” on the Remote for 3 seconds until the LED extinguishes will emit the ID
code to the receivers, subject to house code slide switch being set at the right
position as mentioned below. The procedure of learning the ID code by the
Receiver is clearly described on the Receiver’s manual.
Press 1st. set of
On button
Press 1st. set of
Off button
Press 1st. set of
On & Off button
simultaneously
for more than 3
seconds
Press 2nd. set of
On button
Press 2nd. set of
Off button
Press 2nd. set of
On & Off button
simultaneously
for more than 3
seconds
On
On
Off/Learn
Off
Dimmer
Receiver’s
(AD121, B410D)
operating status
Dimmer On,
Start/Stop
Dimmer Off
Lock
Lock compulsorily
(refer to ”a” as
mentioned below)
Lock compulsorily
(refer to “a” as
mentioned below)
On
On
Off/Learn
Off
Dimmer On,
Start/Stop
Dimmer Off
Lock
Lock compulsorily
(refer to “a“ as
mentioned below)
Lock compulsorily
(refer to “a” as
mentioned below)
OPERATION
1. To work with the EZ Alarm (SE131), set House code slide switch to the “A”
position:
Remote’s operating status
Remote’s RF
transmission
EZ Alarm operating
status
Press the
button
Instant arm
Instant
Press the
button
Delay arm
Delay
Press the
button
Chime
Chime
Press the
button
Disarm/Learn (press
Off/Learn
and hold for 3 seconds)
a. Lock compulsorily
Pressing 1st. set of On & Off button simultaneously for more than 3 seconds
will emit lock command to On/Off Receiver/Dimmer Receiver which will stop
receiving signal from any other devices. However, lock command can be
released by pressing “on” button on the Remote Transmitter or pressing the
ON/OFF knob on the On/Off Receiver/Dimmer Receiver directly.
a. The LED will illuminate each time the button is pressed.
b. The length of time to press the
button may decide what kind of RF
signal will be sent to the Receivers. Press the
button, an off radio
signal will be emitted. Press and hold the
button for more than 3
seconds until the LED extinguishes, a code learning command will be
transmitted.
b. Pressing the “OFF” button will emit off signal to turn off the lighting fixture
connected to the On/Off Receiver (AN121, B410N) or Dimmer Receiver
(AD121, B410D), whereas the code learning command will be transmitted by
pressing the “OFF” button for more than 3 seconds until the LED
extinguishes.
2. To be compatible with On/Off Receiver (AN121, B410N), Dimmer Receiver
(AD121, B410D) and Lantern Receiver (ED102), set the house code slide
switch to “B”, “C” or “D” position.
TROUBLESHOOTING
Symptom
Press button, LED not illuminating
No response with the Receiver
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one of the following measures:
Recommendation
1. Reverse battery polarity
2. Run out of battery
1. Check if learning the ID code has
been processed
2. Check if the procedure of ID code
learning is correct
IMPORTANT: It is compatible with the following receivers of our O-net series
products, serving as a transmitter.
On/Off Receiver (B410N, AN121)
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Dimmer Receiver (B410D, AD121,)
Lantern Receiver (ED102)
EZ Alarm (SE131)
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
The member of O-NET series is on the increase. Visit our website
www.everspring.com for update information.
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user's authority to
operate this equipment.
SPECIFICATION
Important Note:
Battery Type
Transmitting Range
Frequency Range
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment.
CR2032 3V x 1 pc
30 meters min. (in an open space)
315 MHz or 433 MHz
**Specifications subject to change and improvement without notice.
End users must follow the specific operating instructions for satisfying RF
exposure compliance.
A501110439R01
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Mobile of end product
Federal Communication Commission Interference Statement

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2006:07:14 16:32:18+08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2006:07:14 16:49:11+08:00
Metadata Date                   : 2006:07:14 16:49:11+08:00
Format                          : application/pdf
Creator                         : Elaine
Title                           : Microsoft Word - 使用手冊.DOC
Document ID                     : uuid:7a2600f9-729f-4561-8071-78d507cdb23f
Instance ID                     : uuid:5a706c41-f978-4da0-95b2-a0b77518e2bc
Page Count                      : 3
Author                          : Elaine
EXIF Metadata provided by EXIF.tools
FCC ID Filing: FU5SR102

Navigation menu