Everspring Industry Co ST814 Temperature/Humidity Detector User Manual UserMan
Everspring Industry Co Ltd Temperature/Humidity Detector UserMan
UserMan
LCD Display ST814 Temperature/Humidity Detector Temp./Humid. ON Temp./Humid. OFF Linking Signal TM The Temperature/Humidity Detector is a Z-Wave enabled device which is fully compatible with any Z-WaveTM enabled network. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-WaveTM enabled networks. Inclusion of this detector on other manufacturer’s Wireless Controller menu allows remote operation of connected modules when the detector is triggered. Radio Frequency Status Max.Temp./Humidity Min.Temp./Humidity The Temperature/Humidity Detector is designed to monitor the current temperature and humidity of ambient environment. The reading of temperature/humidity can be reported to you on a regular base at your disposal. If temperature/humidity reaches set points, the detector will send alerts to associated devices for further execution. Since sudden temperature/humidity change may cause health problems to people such as elderly or very young children, Temp./Humid. Detector provides you most up-to-date temperature and humidity reading for you to watch your family’s health. Function Inclusion Exclusion Front View Association Side View Temperature °C/°F Humidity % The function key is used to carry out inclusion, exclusion, association and reset. When the detector is first powered up, the reading in RF mode is 00 which implies that it hasn’t been allocated a node ID and cannot work with Z-WaveTM enabled devices. The Temp./Humid. Detector will stay “awake” for 10 minutes when power is first applied to allow time for configuration. Please get familiar with the terms below before starting the operations. Low Battery Include to or Exclude from a Z-WaveTM Network Product Overview Beep tone ON Rear View Reset 1 LCD Screen 2 Function Keys Description Add a Z-Wave enabled device (e.g.Temp./Humid Detector) to Z-Wave network. Delete a Z-Wave enabled device (e.g. Temp./Humid Detector) from the network. After inclusion, you have to define the relationship between devices. Trough association, device can be assigned as master/slave, and specify which slave is going to be controlled by which master. Restore Temp./Humid Detector to factory default. Auto Inclusion Select modes/Change setting Select temperature unit/Linking Increase settings, displays max. temperature/humidity or enable MAX/▲ RF & beep tone Decrease settings, displays min. temperature/humidity or disable MIN/▼ RF & beep tone 3 Temperature/Humidity Sensor 4 Mounting Bracket The function of auto inclusion will be executed as long as the Detector does not have node ID. 1. The power is first supplied where no node ID code has been allocated. 2. The execution of exclusion/reset is successful where the stored node ID is cleared. Note: Auto inclusion timeout is 4 minutes during which the node information of explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the key. Wall Mounting The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the setup function, and to include/exclude/associate devices. 2. Where marked, drill holes into mounting surface using an appropriate size drill bit and insert the plastic wall plugs supplied respectively. Function No node ID Inclusion Exclusion Reset Association Description The Z-Wave Controller does not allocate a node ID to the detector. 1. Have Z-Wave Controller entered inclusion mode. 2. Pressing key 3 times within 1.5 seconds will enter inclusion mode. 1. Have Z-Wave Controller entered exclusion mode. 2. Pressing key 3 times within 1.5 seconds will enter exclusion mode Node ID has been excluded 1. Pressing key 3 times within 1.5 seconds will enter inclusion mode 2. Within 1 second, press key again and hold it until long beep tone is off 3. Node ID has been excluded, restores to factory default. 1. Have Z-Wave Controller entered association mode. 2. Pressing key 3 times within 1.5 seconds will enter association mode 3. There are two groupings – 1 and 2. Refer to Z-Wave’s Groupings as described on page 5. 1. Place mounting bracket over a desired location on the wall. Through the 2 screw holes of the bracket, mark the mounting surface with a pencil. 3. Screw mounting bracket onto the mounting surface. screws are flush with the bracket. LED Indication The RF reading displays 00 (MODE 7) flashes Ensure that the 4. Snap the Temp./Humid. Detector into place on the mounting bracket. 5. Secure with the fixing screw supplied. 2 Plastic Wall Plug flashes The RF reading displays 00 (MODE 7) flashes FIGURE 1 FIGURE 2 Table Placing 1. Insert the stand into the hole on mounting bracket and turn 90 degrees clockwise. The RF reading displays 00 (MODE 7) flashes 2. Once snapped in place, the detector can be placed on a shelf, table or other surface where the temperature and humidity measurements are desired. Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node ID allocated by Z-Wave Controller means exclusion. Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. FIGURE3 Choosing a Suitable Location FIGURE 4 Note: Take care when fixing the detector to a metal surface, or mounting within 1m of metalwork (i.e. radiators, water pipes, etc) as this could affect the radio range of the device. The Temp./Humid. Detector can either be mounted on a wall or can be freestanding on a table. Please consider a most suitable way before mounting/ placing it. Installation Mode Please follow the steps below in sequence to load the batteries. 1. Undo and remove the screw from the bottom edge of the detector to detach the rear cover. 2. Open the mounting bracket. 3. Unscrew the screw from the battery cover. Function Current temperature display (°C/°F) Current humidity display (%) Setting for temperature trigger-ON value Setting for temperature trigger-OFF value Setting for humidity trigger-ON value Setting for humidity trigger-OFF value Setting for turning on/off Radio Frequency Setting for turning on/off beep tone 4. Remove the battery cover. 5. Insert 3 AA-size 1.5V alkaline batteries to the battery compartment, ensuring correct polarity is put. MODE 1 & MODE 2 are showing as main displays on the screen. Once mode setting is finished (MODE 3 to MODE 8), the screen will return to main display automatically after 12 seconds, or by pressing to return to main display. 6. Replace the battery cover and then engage the detector to the rear cover firmly. 1. Temperature Note: After removing batteries, please wait for 5 seconds before replacing them. 1.1 Display of Current Temperature Operation Press There are 8 modes available for selection. Press for different settings. Mode 1 Mode 2 to select desired mode and select MODE 1 to display current temperature, and toggle to select the unit of temperature (。C /。F). The temperature ranges from -20。 C to 50。 C . To show the last record of max/min temperature, press or . To clear the record, press both and at the same time. Threshold Limit Warning: If the temperature is reaching the limit, the icon of MAX or MIN will be displayed on the screen. Mode 3 Ice Warning: If the temperature falls to 0。 C , temperature display will illuminate with LCD back light and beep tone will sound continuously for 1 second. Press any key to stop the beep tone. Mode 4 Mode 5 1.2 Temperature Trigger-ON Mode 6 Press Icon and select MODE 3 to enter setting of temperature trigger-ON. flashes and the screen shows the recorded trigger-ON temperature. If no value is preset, the screen will display “ - - -。 C ”. Mode 7 Mode 8 down at least 2。C from the preset value before it can be triggered again. For example, if the detector is triggered on at 20。 C , then the temperature must be ≧22。C or ≦18。C before it can be re-triggered. To adjust trigger-ON value, press and hold for 5 seconds until a long beep is sounded. The “- - -” starts flashing. Use and button to adjust the degree of temperature, and hold or button to scan 。 。 through the temperature reading from -20 C to 50 C. Once the value is selected, to cancel. press to confirm setting or press 2. Humidity 2.1 Display of Current Humidity To clear the trigger-ON record, press both and The record is cleared after a long beep is sounded. at the same time. Press If the temperature reaches the preset trigger-ON value, Temp./Humid. Detector will emit RF signal. The screen of detector returns to MODE 1 and the icon is flashing with backlight illuminate and beep tone sounds for 1 second. Press any key to stop the beep tone. and select MODE 2 to display current humidity. The humidity ranges from 20% RH to 90%RH. To show the last record of max/min humidity, press or . To clear the record, press both or at the same time. 1.3 Temperature Trigger-OFF Threshold Limit Warning: If the humidity is reaching the limit, the icon of MAX or MIN will be displayed on the screen. Press Icon 2.2 Humidity Trigger-ON and select MODE 4 to enter setting of temperature trigger-OFF. flashes and the screen shows the recorded trigger-OFF temperature. If no value is preset, the screen will display “- - -。 C”. Press and select MODE 5 to enter setting of humidity trigger-ON. Icon flashes and the screen shows the recorded trigger-ON humidity. If no value is preset, the screen will display “- - -%”. To adjust trigger-OFF value, press and hold for 5 seconds until a long beep is sounded. The “- - -” starts flashing. Use and button to adjust the degree of temperature, and hold or button to scan through the temperature reading from -20。 C to 50。 C . Once the value is selected, press to confirm setting or press To adjust trigger-ON value, press and hold for 5 seconds until a long beep is sounded. The “- - -” starts flashing. Use and button to adjust the percentage of humidity, and hold and button to scan through the humidity reading from 20%RH to 90%RH. Once the value is selected, press to confirm setting or press to cancel. to cancel. To clear the trigger-OFF record, press both and The record is cleared after a long beep is sounded. at the same time. To clear the trigger-ON record, press both and The record is cleared after a long beep is sounded. If the temperature reaches the preset trigger-OFF value, Temp./Humid. Detector will emit RF signal. The screen of detector returns to MODE 1 and the icon is flashing with backlight illumination and beep tone sounds for 1 second. Press any key to stop the beep tone. at the same time. If the humidity reaches the preset trigger-ON value, Temp./Humid. Detector will emit RF signal. The screen of detector returns to MODE 2 and the icon is flashing with backlight illuminate and beep tone sounds for 1 second. Press any key to stop the beep tone. Note: The temperature trigger-ON and trigger-OFF cannot be set equal; there MUST be at least 2。C difference in between. For example, if now the trigger-OFF temperature is already set to be 20。 C , so trigger-ON temperature can only be ≦18。C or ≧22。C (values between 18。C and 22。C cannot be set). 2.3 Humidity Trigger-OFF Press and select MODE 6 to enter setting of humidity trigger-OFF. Icon flashes and the screen shows the recorded trigger-OFF humidity. If no value is preset, the screen will read - - -%. Once the detector has been triggered, the temperature must increase or cool To adjust trigger-OFF value, press and hold for 5 seconds until a long beep is sounded. The “- - -” starts flashing. Use or button to scan through the humidity reading from 20%RH to 90%RH. Once the value is to cancel. selected, press to confirm setting or press To clear the trigger-OFF record, press both and The record is cleared after a long beep is sounded. Programming 1. Z-Wave’s Groups (Association Command Class Version 2) The Temp./Humid. Detector can be set to send reports to or control associated Z-Wave devices. It supports two association groups with one node support for Grouping 1 and three nodes support for Grouping 2. at the same time. Grouping 1 includes POWER_APPLIED, SENSOR_MULTILEVEL _REPORT and BATTERY_REPORT_COMMAND If the humidity reaches the preset trigger-OFF value, Temp./Humid. Detector will emits RF signal. The screen of detector returns to MODE 2 and the icon is flashing with backlight illuminates and beep tone sounds for 1 second. Press any key to stop the beep tone. Grouping 2 includes BASIC_SET 1-1 Grouping 1 (Max. Node = 1) Note: The humidity of trigger-ON and trigger-OFF cannot be set equal; there MUST be at least 5% difference in between. For example, if now the trigger-ON humidity is already set to be 50%, so trigger-OFF humidity can only be ≦45% or ≧55%. (Values between 45% and 55% cannot be set.) Once the detector has been triggered, the humidity must raise up or drop down at least 5% from the preset value before it can be triggered again. For example, if the detector has been triggered on at 50%, then the temperature must be ≧55% or ≦45% before it can be re-triggered. 1-1-1 POWER_APPLIED command Whenever power is applied, it will send ALARM_REPORT command to the nodes of Grouping 1 to inform the devices that the detector is powered up. ALARM_REPORT Command [Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01] 3. Radio Frequency 1-1-2 MULTILEVEL_SENSOR_REPORT This function is designed to enable or disable the sending of RF command which comprised of Z-wave protocol to the associated nodes, as Temp./Humid. Detector has been triggered on/off. Press and select MODE 7, the icon should flash. Press turn On (enable) the function or to turn OFF (disable) the function. The detector will emit SENSOR_MULTILEVEL_REPORT to inform the nodes of Grouping 1 automatically its current temperature and humidity. Refer to the section of Z-Wave’s Configuration as described on page 6 for settings of auto report configuration. to 1-1-2-1 Humidity Note: If the RF mode is OFF, no command will be sent even the Temp./Humid. Detector has been triggered. If RF is ON and the detector has been triggered, the RF command will be sent to nodes of Grouping 2. SENSOR_MULTILEVEL_REPORT [Command Class Sensor Multilevel, Sensor Multilevel Report, Sensor Type = 0 x 05 (Relative Humidity), Precision+Scale+Size = 0 x 01, Sensor Value 1 = 20-90%] If the RF reading is 00, it implies no node ID has been allocated by Z-Wave Controller. Please execute inclusion mode as described on page 1. 4. Beep Tone Example: Sensor Value 1 = 0x23 Humidity Value = Sensor Value = 35 (%) To set the beep tone, press and select MODE 8. The icon flashes. Press for ON and for OFF. If it is ON, a beep tone will be sounded whenever a button is pressed; 4 continuous beep tones will be sounded for 1 second if the detector has been triggered. 1-1-2-2 Temperature (Celsius) device associated into Grouping 1 of Temp./Humid. Detector, even if the RF function is set to disable. SENSOR_MULTILEVEL_REPORT [Command Class Sensor Multilevel, Sensor Multilevel Report, Sensor Type = 0 x 01 (Air Temperature), Precision+Scale+Size = 0 x 22, Sensor Value 1 = (High Byte of Temperature Value), Sensor Value 2 = (Low Byte of Temperature Value)] 1-2 Grouping 2 (Max. Node = 3) 1-2-1 Control Other Devices (Basic Set) When the detector is triggered, it will emit BASIC_SET_COMMAND to the nodes of Grouping 2. Example: Sensor Value 1 = 0x01 Sensor Value 2 = 0x31 Temperature (C) = (Sensor Value 1*256 + Sensor Value 2)/10 = (1*256+49)/10 = 30.5 (C) BASIC_SET Command Trigger ON: [Command Class Basic, Basic Set, Value = 0xFF] Trigger OFF: [Command Class Basic, Basic Set, Value = 0] 1-1-2-3 Temperature (Fahrenheit) SENSOR_MULTILEVEL_REPORT [Command Class Sensor Multilevel, Sensor Multilevel Report, Sensor Type = 0 x 01 (Air Temperature), Precision+Scale+Size = 0 x 2A, Sensor Value 1 = (High Byte of Temperature Value), Sensor Value 2 = (Low Byte of Temperature Value)] Please refer to the table below, configuration parameter 1, for the setting of basic set command. 2. Z-Wave’s Configuration The table below lists the configuration parameters and the value range for users to set up the detector. 1-1-3 Low Battery Report Parameter When the battery level of the detector drops to an unacceptable level, the icon will appear on the LCD and the detector will emit ALARM_REPORT command to the nodes of Grouping 1. ALARM_REPORT Command: [Command Class Alarm, Alarm Type = 0x01, Alarm Level = 255(0xFF)] The users can also enquire the battery status of the detector by sending BATTERY_ GET command via controller. Once the detector receives the command, it will return BATTERY_REPORT command. BATTERY_REPORT Command [Command Class Battery, Battery Report, Battery Level = 20%-100%] If it displays with a message of “Battery Level = 255 (0xFF)”, it implies that the detector is at low battery status. Please replace the batteries as soon as possible, otherwise the detector will enter Shut Down mode. Note: The detector will emit a low battery command as long as there is a Function Basic Set Level Size (Byte) Temperature Trigger-ON Value Temperature Trigger-OFF Value Humidity Trigger-ON Value Humidity Triger-OFF Value Auto Report (Time Interval) Value Unit 0~99 % of Brightness (Dimmer Level) -20~50 or 99 Degree -20~50 or 99 Degree 20~90 or 99 Default Set/ Factory Default Description 99 / 99 Set basic set value to be on (or Dim Level) /off 30 / 99 0: Disable Set temp.trigger-ON value to be _ degree. 20 / 99 99: Clear Temp. trigger-ON value Set temp.trigger-OFF value to be _ degree. 99: Clear Temp. trigger-OFF value Set humid. trigger-ON value to be _%. 20~99 or 99 1~1439 or 99 Minutes 50 / 99 40 / 99 0/0 99: Clear Humid. trigger-ON value Set humid. trigger-OFF value to be _%. 99: Clear Humid. trigger-OFF value Set auto report time interval to be _ mins 0: Disable auto report Parameter Function Size (Byte) Value Unit Auto Report (Temp. Change) 1~70 or Degree Set auto report temp. trigger interval to be _ degree. 0: Disable auto report Set auto report humid. trigger interval to be _ %. Auto Report (Humid. Change) 5~70 or Default Set/ Factory Default 0/0 0/0 The Temp./Humid. detector can be set to emit report of humidity status to the nodes of Grouping 1 automatically once the humidity change exceeds set %RH. The humidity difference range can be set from 5%RH to 70%RH. For instance, if humidity difference is set in 5%RH, the detector will report its current humidity status once the humidity difference exceeds 5%RH. Please refer to the parameter 8 of configuration table on page 6. Description 0: Disable auto report Note: Auto report mechanism may cause a lot of power consumption if it operates regularly. Please base on actual requirements for determining whether to enable the function of auto report. Note: Default set is the preset value of the detector. For instance, if default set of Temp. trigger-ON is selected, the detector will be triggered ON if temperature reaches 30。C . You can skip the hassle of selecting a value from -20 to 50 degrees if default set is selected. Factory default value is the original value of the detector without any setting. Once the function of reset is executed, the detector will be restored to its factory default status, so as the settings. 2-2 Wakeup Configuration The Temp./Humid. Detector stays in sleep status for the majority of time in order to conserve battery power. However, it can be woken up by either triggers of temp./humid. or set time for the controller to do further setting. 2-2-1 Wakeup Time Interval The detector stays in wakeup status for 10 minutes. If the detector receives RF command from the controller during these 10 minutes, it will extend waking time for another 10 minutes until no more RF command is received. Once the wakeup time is up, the detector goes back to sleep status. 2-1 Auto Report 2-1-1 Time Interval The Temp./Humid. Detector can be set to emit report of current status to the nodes of Grouping 1 automatically at a set time. The time interval can be set from 1 minute to 24 hours. For instance, if time interval is set in 1 minute, the detector will report its status once per minute. Please refer to the parameter 6 of configuration table on page 6. 2-2-2 Sleep Time Interval The sleep interval can be set from 1 minute to 4660 hours (about 194 days). The unit of time is in seconds. The preset sleep time interval is 1 hour. 2-1-2 Temperature Change The Temp./Humid. Detector can be set to emit report of temperature status to the nodes of Grouping 1 automatically once the temperature changing exceeds set degree. The temperature difference range can be set from 1。 Cto 70。 C. For instance, if temperature difference is set in 3. Command Classes The Temp./Humid. Detector supports Command Classes including… 1。C , the detector will report its current temperature status once the temperature difference exceeds 1。 C. Please refer to the parameter 7 of * COMMAND_CLASS_BASIC * COMMAND_CLASS_VERISON * COMMAND_CLASS_BATTERY * COMMAND_CLASS_WAKE_UP_V2 * COMMAND_CLASS_CONFIGURATION * COMMAND_CLASS_ASSOCIATION_V2 configuration table on page 6. 2-1-3 Change of Humidity energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. * COMMAND_CLASS_MANUFACTURER_SPECIFIC * COMMAND_CLASS_SENSOR_MULTILEVEL * COMMAND_CLASS_MULTI_INSTANCE_V2 * COMMAND_CLASS_ALARM Troubleshooting Symptom Possible Cause Recommendation LED cannot be displayed 1. 1. 2. Replace a new battery Refit the battery with correct polarity 1. Please leave the detector without operating or do any setting for a period Do not open the detector; send it to the local retailer. Temperature/humidity reading is incorrect Run out of battery power. 2. Check if reverse battery polarity The Detector is out of order 2. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Specifications* Operating Frequency 908.42 MHz (US) / 869 MHz (RU) Operating Temperature Range -10°C - 50°C Relative Humidity Range 20% - 90% Temperature Unit °C / °F Battery Type 1.5V x 3 Alkaline/AA type battery Battery Life 1.2 years** Operating Range Up to 30 meters line of sight (indoor) This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. FCC ID *Specifications are subject to change without notice **10 triggers per day A501112116R Contact your local government for information regarding the collection systems available. 2013/09 If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. Federal Communication Commission Interference Statement When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:10:04 17:44:37+08:00 Create Date : 2013:10:04 17:44:37+08:00 Format : application/pdf Title : Microsoft Word - Manual_ST814_A501112116R_ZDK4.54_美俄規 Creator : 101199 Document ID : uuid:35bb3196-15f0-40ac-800f-639c5ec86310 Instance ID : uuid:106b3f9a-147c-435f-a31b-a4e8b1775608 Page Count : 8 Author : 101199EXIF Metadata provided by EXIF.tools