Extreme Networks OAP36A HiPath Wireless Outdoor Access Point User Manual 9034581 AP3660 QuickInstGde print

Extreme Networks, Inc. HiPath Wireless Outdoor Access Point 9034581 AP3660 QuickInstGde print

user manual

Installing the Enterasys Wireless Outdoor
AP3660
Forcompleteinstallationinstructionsandinformation
abouttheEnterasysWirelessOutdoorAP3660,seethe
EnterasysWirelessOutdoorAP3660InstallationGuideathttp:/
/www.enterasys.com/support/manuals.
Overview of the Enterasys Wireless Outdoor
AP3660
TheEnterasysWirelessOutdoorAPenablesyoutoextend
yourWirelessLANbeyondtheboundariesofindoor
locations.Theyareresistanttoharshoutdoorconditions
andextremetemperatures.Usingtheadvancedwireless
distributionmeshfeatureofEnterasysWirelessLAN,the
EnterasysWirelessOutdoorAP3660canextendyour
WirelessLANtooutdoorlocationswithoutEthernet
cabling.Amountingbracketisavailabletoenablequick
andeasymountingoftheEnterasysWirelessOutdoorAPs
towallsandpoles.
Figure 1 Enterasys Wireless Outdoor AP3660
TheEnterasysWirelessOutdoorAP3660supportsthe
902.11n,802.11a,802.11g,andfullbackwardcompatibility
withlegacy802.11bdevices.TheEnterasysWireless
OutdoorAP3660withexternalantennaconnectors
supportsavarietyofantennas,providingrangeand
coverageversatility.
TheEnterasysWirelessOutdoorAP3660interoperatesfully
withEnterasysWirelessLAN,includingsupportfor
VoWLAN,branchofficemode,guestservices,RTLS,
availabilityandmobilityfeatures.
Unpacking the Enterasys Wireless Outdoor AP3660
UnpacktheAPfromitscarton.Thefollowingcomponents
aresuppliedwiththeEnterasysWirelessOutdoorAP3660
package
•1mountingbracket
•2stainlesssteeltiebackstrapsthatsupportpole
diametersupto4inches
•4M6screws
•4washers
Electrical Hazard: Only qualified personnel should perform installation
procedures.
AntennaConnectors
•4springwashers
•1groundscrew
•RJ45waterproofconnectorassembly
•AprintedcopyoftheEnterasysWirelessOutdoorAccess
PointQuickReference‐AP3660
Mounting and Connecting the Enterasys
Wireless Outdoor AP3660
MountingandconnectingtheEnterasysWirelessOutdoor
AP3660canbeaccomplishedeasilyandsafelybyfollowing
theinstructionsinthefullEnterasysWirelessOutdoorAccess
PointAP3660InstallationGuide.Theinstallationofthe
OutdoorAPshouldbeperformedbyaprofessional
installertoensureproperoperationandcompliancewith
safetyguidelines.
Mounting the Outdoor AP3660:
1. AttachthemountingbrackettotheAP3660usingfour
M6screwsandwashers.Youcanattachthebrackettothe
APineithertheverticalorhorizontalpositionasshown
inFigures2and3.
Figure 2 Mounting Bracket - Vertical Position
Figure 3 Mounting Bracket - Horizontal Position
2. YoucanmounttheAP3660toeitherapoleorawall:
a. TomounttheAP3660withtheattachedmounting
brackettoapole,usethesuppliedstainlesssteeltie
backstraps.
YoucanmounttheAP3660toapoleinoneofthree
possibleconfigurations,asshowninFigures4,5,and6.
Note: Before you start mounting the Enterasys Wireless Outdoor
AP3660, read the Safety Guidelines below.
Figure 4 AP3660 - Pole Mount Option 1
Figure 5 AP3660 - Pole Mount Option 2
Figure 6 AP3660 - Pole Mount Option 3
b.MounttheAP3660andtheattachedmountingbracket
toawallusingfourwood/gyprockscrewsasshownin
Figure7.
Figure 7 AP3660 - Wall Mount
3. Installtheexternalantennaintendedforareacoverage.
Forinformationaboutantennaselectionandinstallation,
refertotheExternalAntennaSitePreparationand
InstallationGuide.
4. AttachtheexternalantennacablestotheRPN
connectorsontheAP.
Connecting and powering the AP
YoucanpoweruptheAPinoneofthefollowingways:
•PoweroverEthernet:AddingPoEinjector
YoucanprovidepowertotheEthernetcablewithaPoE
injector.ThePoEinjectormustbe802.3atcompliant.The
PoEinjectorisnotprovidedwiththeAP.
AwaterproofRJ45connectorisprovidedtoconnectthe
PoEinjectortotheAP3660.YoumustconnecttheRJ45
connectortotheRJ45cable.Forinstructions,refertothe
fullEnterasysWirelessOutdoorAccessPointAP3660
InstallationGuide.
•Powerbyexternalpowersupply:
Youcanpurchaseanexternalpowersupplyunit(WS
PS3660MR)topowertheAP.SeeyourEnterasyssales
representativefordetails.
Forpowersupplyinstallationinstructions,refertothe
EnterasysWirelessOutdoorAccessPointAP3660Installation
Guide.
Regulatory and Compliance information
Federal Communications Commission (FCC) Notice:
ThisdevicecomplieswithPart15oftheFCCrules.
Operationissubjecttothefollowingtwoconditions:(1)this
devicemaynotcauseharmfulinterference,and(2)this
devicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
Industry Canada Notice:
ThisdigitalapparatusdoesnotexceedtheClassBlimitsfor
radionoiseemissionsfromdigitalapparatussetoutinthe
RadioInterferenceRegulationsfortheCanadian
DepartmentofCommunications.
Leprésentappareilnumériquen’émetpasdebruits
radioélectriquesdépassantleslimitesapplicablesaux
appareilsnumériquesdelaclassBprescritesdansle
Règlementsurlebrouillageradioélectriqueédictéparle
ministèredesCommunicationsduCanada.
RefertotheHiPathWirelessController,AccessPoints,and
ConvergenceSoftwareUserGuideInstallationGuide,
AppendixB,ʺRegulatoryinformation,ʺforcomplete
regulatoryinformation.
Warning: Changes or modifications made to this device which are
not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment
17x11 bleed template; DragonNotice; large text
Safety Guidelines
Thissectioncontainsnoticesthatyouhavetoadhereto
ensureyourpersonalsafetyandtopreventanydamageto
theequipment.
Qualified Personnel:
Grounding Warning:
Lightning Protection Warning:
Electrical Hazard: Only qualified personnel should perform
installation procedures. Within the context of the safety notes in
this documentation qualified persons are defined as persons who
are authorized to commission, ground and label devices, systems
and circuits in accordance with established safety practices and
standards. A qualified person understands the requirements risks
involved with installing outdoor electrical equipment in accordance
with national codes.
Warning: To operate the Enterasys Wireless Outdoor AP3660
safely, the chassis ground connector must have a suitable cable
connected. Do not use the Enterasys Wireless Outdoor AP3660
without a ground cable connected.
Warning: Antennas installed outdoors must be within the area
covered by a lightning protection system. Make sure that all
conducting systems entering from outdoors can be protected by a
lightning protection potential equalization system.When
implementing your lightning protection concept, make sure you
adhere to the VDE 0182 or IEC 62305 standard.
The AP3660 has a built-in lightning protector; no external lightning
protector is required. You must however note that the lightning
protector is not an adequate protection against a lightning strike.
The lightening protector only works within the framework of a
comprehensive lightning protection concept. If you have
questions, ask a qualified specialist company.
ѻક䇈ᯢк䰘ӊ
Supplement to Product Instructions
᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance)
䚼ӊৡ⿄
(Parts) 䪙
3E
∲
+J
䬝
&G
݁Ӌ䫀
&U

໮⒈㘨㣃
3%%
໮⒈Ѡ㣃䝮
3%'(
䞥ሲ䚼ӊ
(Metal Parts)
h ƻ ƻ h ƻ ƻ
⬉䏃῵ഫ
(
Circuit Modules)
h ƻ ƻ h ƻ ƻ
⬉㓚ঞ⬉㓚㒘ӊ
(
Cables & Cable Assemblies)
h ƻ ƻ h ƻ ƻ
ล᭭੠㘮ড়⠽䚼ӊ
(Plastic and Polymeric parts)
ƻ ƻ ƻ ƻ ƻ h
⬉䏃ᓔ݇
(
Circuit Breakers)
ƻ ƻ h h ƻ ƻ
ƻ˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼ SJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎSJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖DŽ
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.
ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎
߃߯կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ⊼ᛣ೼᠔ଂѻકЁৃ㛑Ӯгৃ㛑ϡӮ৿᳝᠔᳝᠔߫ⱘ䚼ӊDŽ
This table shows where these substances may be found in the supply chain of Enterasys’ electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.
50
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟ݠЁ᠔㾘ᅮⱘᴵӊϟᎹ԰
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.
䰸䴲঺໪⡍߿ⱘᷛ⊼ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫᶤѯ䳊䚼ӊӮ
᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ՟བ⬉∴ऩܗ῵ഫ䌈೼݊ѻકϞ
Hazardous Substances
ThisproductcomplieswiththerequirementsofEuropean
Directive,2002/95/EC,RestrictionofHazardousSubstances
(RoHS)inElectricalandElectronicEquipment.
European Waste Electrical and Electronic
Equipment (WEEE) Notice
InaccordancewithDirective2002/96/ECoftheEuropean
Parliamentonwasteelectricalandelectronicequipment(WEEE):
1. Thesymbolaboveindicatesthatseparatecollectionofelectrical
andelectronicequipmentisrequiredandthatthisproductwas
placedontheEuropeanmarketafterAugust13,2005,thedate
ofenforcementforDirective2002/96/EC.
2. Whenthisproducthasreachedtheendofitsserviceablelife,it
cannotbedisposedofasunsortedmunicipalwaste.Itmustbe
collectedandtreatedseparately.
3. IthasbeendeterminedbytheEuropeanParliamentthatthere
arepotentialnegativeeffectsontheenvironmentandhuman
healthasaresultofthepresenceofhazardoussubstancesin
electricalandelectronicequipment.
4. Itistheusers’responsibilitytoutilizetheavailablecollection
systemtoensureWEEEisproperlytreated.
Forinformationabouttheavailablecollectionsystem,pleasego
towww.enterasys.com/services/support/ orcontactEnterasys
CustomerSupportat35361705586(Ireland).
Declaration of Conformity
A“DeclarationofConformity”inaccordancewiththepreceding
directivesandstandardshasbeenmadeandisonfileatDellInc.
ProductsEuropeBV,Limerick,Ireland.
Notice
EnterasysNetworksreservestherighttomakechangesin
specificationsandotherinformationcontainedinthisdocument
anditsWebsitewithoutpriornotice.Thereadershouldinall
casesconsultEnterasysNetworkstodeterminewhetheranysuch
changeshavebeenmade.
Thehardware,firmware,orsoftwaredescribedinthisdocument
issubjecttochangewithoutnotice.
INNOEVENTSHALLEnterasysNetworksBELIABLEFOR
ANYINCIDENTAL,INDIRECT,SPECIAL,OR
CONSEQUENTIALDAMAGESWHATSOEVER(INCLUDING
BUTNOTLIMITEDTOLOSTPROFITS)ARISINGOUTOFOR
RELATEDTOTHISDOCUMENT,WEBSITE,ORTHE
INFORMATIONCONTAINEDINTHEM,EVENIFEnterasys
NetworksHASBEENADVISEDOF,KNEWOF,ORSHOULD
HAVEKNOWNOF,THEPOSSIBILITYOFSUCHDAMAGES.
EnterasysNetworks,Inc.
50MinutemanRoad
Andover,MA01810
©2010EnterasysNetworks,Inc.Allrightsreserved.
PartNumber: 9034581 September 2010
ENTERASYSandENTERASYSNETWORKSandanylogos
associatedtherewith,aretrademarksorregisteredtrademarksof
EnterasysNetworks,Inc.,intheUnitedStatesand/orother
countries.ForacompletelistofEnterasystrademarks,seehttp://
www.enterasys.com/company/trademarks.aspx.
Allotherproductnamesmentionedinthisdocumentmaybe
trademarksorregisteredtrademarksoftheirrespective
companies. Enterasys Wireless
Outdoor Access Point
Quick Reference
AP3660
17x11 bleed template; DragonNotice; large text
P/N 9034581
FCC Statement:
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of
other channels is not possible.
This device and its antenna(s) must not be co-located or operation in conjunction with any other
antenna or transmitter.
FCC NOTICE: To comply with FCC part 15 rules in the United States, the system must be
professionally installed to ensure compliance with the Part 15 certification. It is the
responsibility of the operator and professional installer to ensure that only certified
systems are deployed in the United States. The use of the system in any other
combination (such as co-located antennas transmitting the same information) is
expressly forbidden.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 100cm between the radiator &
your body.
IMPORTANT NOTE:
This module is intended for OEM integrator only and limited to host with brand: enterasys and model:
WS-AP3660. The OEM integrator is still responsible for the FCC compliance requirement of the end
product, which integrates this module.
100cm minimum distance has to be able to be maintained between the antenna and the users for the
host this module is integrated into. Under such configuration, the FCC radiation exposure limits set
forth for a population/uncontrolled environment can be satisfied.
Any changes or modifications not expressly approved by the manufacturer could void the user's
authority to operate this equipment.
USERS MANUAL OF THE END PRODUCT:
In the users manual of the end product, the end user has to be informed to keep at least 100cm
separation with the antenna while this end product is installed and operated. The end user has to be
informed that the FCC radio-frequency exposure guidelines for an uncontrolled environment can be
satisfied. The end user has to also be informed that any changes or modifications not expressly
approved by the manufacturer could void the user's authority to operate this equipment.
LABEL OF THE END PRODUCT:
The final end product must be labeled in a visible area with the following " Contains TX FCC ID:
QXO-OAP36A ". The FCC part 15.19 statement below has to also be available on the label: This
device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference and (2) this device must accept any interference received,
including interference that may cause undesired operation.
IC Statement
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired operation of
the device.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of
other channels is not possible.
This device and its antenna(s) must not be co-located or operation in conjunction with any other
antenna or transmitter.
To reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power (e.i.r.p) is not more than that permitted for
successful communication.
This device has been designed to operate with the antennas listed below, and having a maximum gain
of [23] dB. Antennas not included in this list or having a gain greater than [23] dB are strictly prohibited
for use with this device. The required antenna impedance is 50 ohms.
The device could automatically discontinue transmission in case of absence of information to transmit,
or operational failure. Note that this is not intended to prohibit transmission of control or signaling
information or the use of repetitive codes where required by the technology.
The maximum antenna gain permitted (for devices in the bands 5250-5350 MHz and 5470-5725 MHz)
to comply with the e.i.r.p. limit.
High-power radars are allocated as primary users (meaning they have priority) of the bands
5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to
LE-LAN devices.
IMPORTANT NOTE:
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 100cm between
the radiator & your body.
IMPORTANT NOTE:
This module is intended for OEM integrator only and limited to host with brand: enterasys and model:
WS-AP3660. The OEM integrator is still responsible for the IC compliance requirement of the end
product, which integrates this module.
20cm minimum distance has to be able to be maintained between the antenna and the users for the
host this module is integrated into. Under such configuration, the IC RSS-102 radiation exposure limits
set forth for a population/uncontrolled environment can be satisfied.
Any changes or modifications not expressly approved by the manufacturer could void the user's
authority to operate this equipment.
USERS MANUAL OF THE END PRODUCT:
In the users manual of the end product, the end user has to be informed to keep at least 100cm
separation with the antenna while this end product is installed and operated. The end user has to be
informed that the IC radio-frequency exposure guidelines for an uncontrolled environment can be
satisfied. The end user has to also be informed that any changes or modifications not expressly
approved by the manufacturer could void the user's authority to operate this equipment. IC statement
is required to be available in the users manual: This Class B digital apparatus complies with Canadian
ICES-003. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference and (2) this device must accept any interference received, including interference that may
cause undesired operation.
LABEL OF THE END PRODUCT:
The final end product must be labeled in a visible area with the following " Contains TX IC:
4138A-OAP36A ".

Navigation menu