Extreme Networks OAP36C HiPath Wireless Outdoor Access Point User Manual

Extreme Networks, Inc. HiPath Wireless Outdoor Access Point Users Manual

Contents

Users Manual

P/N 9034605-02Enterasys® WirelessOutdoor Access PointInstallation GuideWS-AP3660
iNoticeEnterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made.The hardware, firmware, or software described in this document is subject to change without notice.IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF OR RELATED TO THIS DOCUMENT, WEB SITE, OR THE INFORMATION CONTAINED IN THEM, EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF, KNEW OF, OR SHOULD HAVE KNOWN OF, THE POSSIBILITY OF SUCH DAMAGES.Enterasys Networks, Inc.50 Minuteman RoadAndover, MA 01810 2012 Enterasys Networks, Inc. All rights reserved.Part Number: 9034605-02 July 2012ENTERASYS, ENTERASYS NETWORKS, ENTERASYS SECURE NETWORKS, NETSIGHT, ENTERASYS NETSIGHT, and any logos associated therewith, are trademarks or registered trademarks of Enterasys Networks, Inc., in the United States and/or other countries. For a complete list of Enterasys trademarks, see http://www.enterasys.com/company/trademarks.aspx.All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.Documentation URL:https://extranet.enterasys.com/downloads/Electrical Hazard: Only qualified personnel should perform installation procedures.Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden.
iiHazardous SubstancesThis product complies with the requirements of European Directive, 2002/95/EC, Restriction of Hazardous Substances (RoHS) in Electrical and Electronic Equipment.European Waste Electrical and Electronic Equipment (WEEE) NoticeIn accordance with Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment (WEEE):1. The symbol above indicates that separate collection of electrical and electronic equipment is required and that this product was placed on the European market after August 13, 2005, the date of enforcement for Directive 2002/96/EC.2. When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must be collected and treated separately.3. It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment.4. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated.For information about the available collection system, please go to www.enterasys.com/support/ or contact Enterasys Customer Support at 353 61 705586 (Ireland).
iiiѻѻક䇈ᯢк䰘ӊSupplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance) 䚼ӊৡ⿄(Parts)  䪙3E∲+J䬝&G݁Ӌ䫀&U໮⒈㘨㣃3%%໮⒈Ѡ㣃䝮3%'(䞥ሲ䚼ӊ(Metal Parts)hƻ ƻ ƻ ƻ ƻ⬉䏃῵ഫ(Circuit Modules)hƻ ƻ ƻ ƻ ƻ⬉㓚ঞ⬉㓚㒘ӊ(Cables & Cable Assemblies)hƻ ƻ ƻ ƻ ƻล᭭੠㘮ড়⠽䚼ӊ(Plastic and Polymeric parts) ƻƻ ƻ ƻ ƻ ƻ⬉䏃ᓔ݇(Circuit Breakers)ƻƻ ƻ ƻ ƻ ƻƻ˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼ SJ/T 11363-2006   ᷛޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽIndicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T 11363-2006 standard. h˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎSJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖DŽIndicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard. ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎߃߯կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ⊼ᛣ೼᠔ଂѻકЁৃ㛑Ӯгৃ㛑ϡӮ৿᳝᠔᳝᠔߫ⱘ䚼ӊDŽThis table shows where these substances may be found in the supply chain of Enterasys electronic information products, as of the date of sale of the enclosed product.  Note that some of the component types listed above may or may not be a part of the enclosed product. 䰸䴲঺໪⡍߿ⱘᷛ⊼ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫᶤѯ䳊䚼ӊӮ᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ՟བ⬉∴ऩܗ῵ഫ䌈೼݊ѻકϞℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟ݠЁ᠔㾘ᅮⱘᴵӊϟᎹ԰The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts are per the symbol shown here, unless otherwise marked.  Certain parts may have a different EFUP (for example, battery modules) and so are marked to reflect such.  The Environmentally Friendly Use Period is valid only when the product is operated under the conditions defined in the product manual.
ivEnterasys Networks, Inc. Firmware License AgreementBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,CAREFULLY READ THIS LICENSE AGREEMENT.This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc., on behalf of itself and its Affiliates (as hereinafter defined) (“Enterasys”) that sets forth Your rights and obligations with respect to the Enterasys software program/firmware (including any accompanying documentation, hardware or media) (“Program”) in the package and prevails over any additional, conflicting or inconsistent terms and conditions appearing on any purchase order or other document submitted by You. “Affiliate” means any person, partnership, corporation, limited liability company, other form of enterprise that directly or indirectly through one or more intermediaries, controls, or is controlled by, or is under common control with the party specified. This Agreement constitutes the entire understanding between the parties, with respect to the subject matter of this Agreement. The Program may be contained in firmware, chips or other media.BY INSTALLING OR OTHERWISE USING THE PROGRAM, YOU REPRESENT THAT YOU ARE AUTHORIZED TO ACCEPT THESE TERMS ON BEHALF OF THE END USER (IF THE END USER IS AN ENTITY ON WHOSE BEHALF YOU ARE AUTHORIZED TO ACT, “YOU” AND “YOUR” SHALL BE DEEMED TO REFER TO SUCH ENTITY) AND THAT YOU AGREE THAT YOU ARE BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES, AMONG OTHER PROVISIONS, THE LICENSE, THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT, ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED PRODUCT TO ENTERASYS OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND.IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS, LEGAL DEPARTMENT AT (978) 684-1000.You and Enterasys agree as follows:1. LICENSE. You have the non-exclusive and non-transferable right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this Agreement.2. RESTRICTIONS. Except as otherwise authorized in writing by Enterasys, You may not, nor may You permit any third party to:(a) Reverse engineer, decompile, disassemble or modify the Program, in whole or in part, including for reasons of error correction or interoperability, except to the extent expressly permitted by applicable law and to the extent the parties shall not be permitted by that applicable law, such rights are expressly excluded. Information necessary to achieve interoperability or correct errors is available from Enterasys upon request and upon payment of Enterasys’ applicable fee.(b) Incorporate the Program in whole or in part, in any other product or create derivative works based on the Program, in whole or in part.(c) Publish, disclose, copy reproduce or transmit the Program, in whole or in part.(d) Assign, sell, license, sublicense, rent, lease, encumber by way of security interest, pledge or otherwise transfer the Program, in whole or in part.(e) Remove any copyright, trademark, proprietary rights, disclaimer or warning notice included on or embedded in any part of the Program.3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You accept the personal jurisdiction and venue of the Commonwealth of Massachusetts courts. None of the 1980 United Nations Convention on the Limitation Period in the International Sale of Goods, and the Uniform Computer Information Transactions Act shall apply to this Agreement.
v4. EXPORT RESTRICTIONS. You understand that Enterasys and its Affiliates are subject to regulation by agencies of the U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain technical products to certain countries, unless a license to export the product is obtained from the U.S. Government or an exception from obtaining such license may be relied upon by the exporting party.If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes.If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export Administration Regulations, in addition to the restriction on transfer set forth in Section 1 or 2 of this Agreement, You agree not to (i) reexport or release the Program, the source code for the Program or technology to a national of a country in Country Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Cambodia, Cuba, Georgia, Iraq, Kazakhstan, Laos, Libya, Macau, Moldova, Mongolia, North Korea, the People’s Republic of China, Russia, Tajikistan, Turkmenistan, Ukraine, Uzbekistan, Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or E:2 (as defined herein) the direct product of the Program or the technology, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a complete plant or any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a major component thereof, if such foreign produced direct product is subject to national security controls as identified on the U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Program (i) was developed solely at private expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Program is considered commercial computer software in accordance with DFARS section 227.7202-3 and its successors, and use, duplication, or disclosure by the U.S. Government is subject to restrictions set forth herein.6. DISCLAIMER OF WARRANTY. EXCEPT FOR THOSE WARRANTIES EXPRESSLY PROVIDED TO YOU IN WRITING BY ENTERASYS, ENTERASYS DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT WITH RESPECT TO THE PROGRAM. IF IMPLIED WARRANTIES MAY NOT BE DISCLAIMED BY APPLICABLE LAW, THEN ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THIRTY (30) DAYS AFTER DELIVERY OF THE PROGRAM TO YOU.7. LIMITATION OF LIABILITY. IN NO EVENT SHALL ENTERASYS OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THE PROGRAM, EVEN IF ENTERASYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THIS FOREGOING LIMITATION SHALL APPLY REGARDLESS OF THE CAUSE OF ACTION UNDER WHICH DAMAGES ARE SOUGHT.THE CUMULATIVE LIABILITY OF ENTERASYS TO YOU FOR ALL CLAIMS RELATING TO THE PROGRAM, IN CONTRACT, TORT OR OTHERWISE, SHALL NOT EXCEED THE TOTAL AMOUNT OF FEES PAID TO ENTERASYS BY YOU FOR THE RIGHTS GRANTED HEREIN.8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys, and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i) license fees due and paid, and (ii) the use, copying and deployment of the Program. You also grant to Enterasys and its authorized representatives, upon reasonable notice, the right to audit and examine during Your normal business hours, Your books, records, accounts and hardware devices upon which the Program may be deployed to verify compliance with this Agreement, including the verification of the license fees due and paid Enterasys and the use, copying and deployment of the Program. Enterasys’ right of examination shall be exercised reasonably, in good faith and in a manner calculated to not unreasonably interfere with Your business. In the event such audit discovers non-compliance with this Agreement, including copies of the Program made, used or deployed in breach of this Agreement, You shall promptly pay to Enterasys the appropriate license fees. Enterasys reserves the right, to be exercised in its sole discretion and without prior notice, to terminate this license, effective immediately, for failure to comply with this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall return to Enterasys the Program and all copies of the Program.9. OWNERSHIP. This is a license agreement and not an agreement for sale. You acknowledge and agree that the Program constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to implement reasonable security measures to protect such trade secrets and copyrighted material. All right, title and interest in and to the Program shall remain with Enterasys and/or its suppliers. All rights not specifically granted to You shall be reserved to Enterasys.
vi10. ENFORCEMENT. You acknowledge and agree that any breach of Sections 2, 4, or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate, and that Enterasys may be entitled to seek timely injunctive relief to protect Enterasys’ rights under this Agreement in addition to any and all remedies available at law.11. ASSIGNMENT. You may not assign, transfer or sublicense this Agreement or any of Your rights or obligations under this Agreement, except that You may assign this Agreement to any person or entity which acquires substantially all of Your stock assets. Enterasys may assign this Agreement in its sole discretion. This Agreement shall be binding upon and inure to the benefit of the parties, their legal representatives, permitted transferees, successors and assigns as permitted by this Agreement. Any attempted assignment, transfer or sublicense in violation of the terms of this Agreement shall be void and a breach of this Agreement.12. WAIVER. A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and will not be construed as a waiver of any subsequent breach of such term or condition. Enterasys’ failure to enforce a term upon Your breach of such term shall not be construed as a waiver of Your breach or prevent enforcement on any other occasion.13. SEVERABILITY. In the event any provision of this Agreement is found to be invalid, illegal or unenforceable, the validity, legality and enforceability of any of the remaining provisions shall not in any way be affected or impaired thereby, and that provision shall be reformed, construed and enforced to the maximum extent permissible. Any such invalidity, illegality, or unenforceability in any jurisdiction shall not invalidate or render illegal or unenforceable such provision in any other jurisdiction.14. TERMINATION. Enterasys may terminate this Agreement immediately upon Your breach of any of the terms and conditions of this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall return to Enterasys the Program and all copies of the Program.
viiContentsAbout This GuideWho Should Use This Guide  .............................................................................................................................ixHow to Use This Guide ......................................................................................................................................ixRelated Documents ............................................................................................................................................xTypographical Conventions  ................................................................................................................................xGetting Help .......................................................................................................................................................xiChapter 1: IntroductionWS-AP3660 Overview .................................................................................................................................... 1-1WS-AP3660 LED Indicators ..................................................................................................................... 1-3Antennas .................................................................................................................................................. 1-4External Antenna Connectors  .................................................................................................................. 1-4Console Port  ............................................................................................................................................ 1-4LAN Port ................................................................................................................................................... 1-4Reset Switch  ............................................................................................................................................ 1-5Audible Buzzer ......................................................................................................................................... 1-5Temperature Sensor  ................................................................................................................................ 1-5Heater Circuit  ........................................................................................................................................... 1-5Chapter 2: InstallationPackage Contents  .......................................................................................................................................... 2-1Unpacking the WS-AP3660  ..................................................................................................................... 2-1Unpacking the WS-AP3660 Power Supply  .............................................................................................. 2-2Separately Ordered Components ................................................................................................................... 2-2WS-AP3660 Installation Procedures  .............................................................................................................. 2-3Attaching the Mounting Bracket  ............................................................................................................... 2-4Mounting the WS-AP3660 to a Wall ......................................................................................................... 2-5Mounting the WS-AP3660 to a Pole  ........................................................................................................ 2-6Attaching Antennas .................................................................................................................................. 2-7LAN/Console Connections (with Cable Gland Adapter Assembly) .......................................................... 2-8Ground Connection ................................................................................................................................ 2-11Power Connections ................................................................................................................................ 2-11WS-AP3660 Power Supply Installation Procedures ..................................................................................... 2-11Attaching the Mounting Bracket  ............................................................................................................. 2-12Mounting the Power Supply to a Wall  .................................................................................................... 2-13Mounting the Power Supply to a Pole .................................................................................................... 2-13Connecting the DC Power Supply to the WS-AP3660 ........................................................................... 2-14Connecting the Power Supply to AC Power ........................................................................................... 2-16Appendix A: SpecificationsAppendix B: Regulatory InformationWS-AP3660 ....................................................................................................................................................B-1WS-AP3660 External Antenna AP ...........................................................................................................B-1United States ............................................................................................................................................B-1FCC Declaration of Conformity Statement ........................................................................................ B-1USA Conformance Standards ........................................................................................................... B-2FCC RF Radiation Exposure Statement............................................................................................ B-2External Antennas ............................................................................................................................. B-3Canada .....................................................................................................................................................B-3
viii  Industry Canada Compliance Statement........................................................................................... B-3Canada Conformance Standards ...................................................................................................... B-3External Antennas ............................................................................................................................. B-4European Community  ..............................................................................................................................B-4Declaration of Conformity in Languages of the European Community.............................................. B-5European Conformance Standards ................................................................................................... B-6External Antennas ............................................................................................................................. B-7Conditions of use in the European Community ................................................................................. B-7European Spectrum Usage Rules ..................................................................................................... B-8Certifications of Other Countries  ....................................................................................................................B-9WS-AP3660 Approved External Antennas .............................................................................................B-10Figures1-1 WS-AP3660 Front View...................................................................................................................... 1-21-2 WS-AP3660 Top View........................................................................................................................ 1-21-3 WS-AP3660 Bottom View................................................................................................................... 1-32-1 Mounting Bracket and Spacer Orientation.......................................................................................... 2-42-2 Completed Bracket Installation........................................................................................................... 2-42-3 Mounting the WS-AP3660 to a Wall ................................................................................................... 2-52-4 WS-AP3660 Pole Mount Options ....................................................................................................... 2-62-5 Attaching Straps to the Mounting Bracket .......................................................................................... 2-72-6 Installing Terminator Caps.................................................................................................................. 2-82-7 RJ45 Cable Gland Adapter Assembly ................................................................................................ 2-82-8 WS-AP3660 Grounding Terminals ................................................................................................... 2-112-9 Mounting Bracket and Spacer Orientation........................................................................................ 2-122-10 Completed Bracket Installation......................................................................................................... 2-122-11 Mounting the Power Supply to a Wall............................................................................................... 2-132-12 Power Supply Pole Mount Options................................................................................................... 2-142-13 WS-AP3660 Power Supply Connections..........................................................................................2-152-14 Power Supply Connections with Drip Loop ...................................................................................... 2-152-15 WS-AP3660 Power Supply AC Connector Assembly ...................................................................... 2-162-16 Power Cable Pin Out Diagram ......................................................................................................... 2-17Tables1-1 WS-AP3660 LED Status Indicators .................................................................................................... 1-42-1 WS-AP3660 Supplied Components ................................................................................................... 2-12-2 WS-AP3660 Power Supply Components ........................................................................................... 2-2A-1 Specifications for the WS-AP3660 .....................................................................................................A-1A-2 Specifications for the WS-AP3660 Power Supply ..............................................................................A-2B-1 European Spectrum Usage Rules ......................................................................................................B-8B-2 List of Approved Antennas - WS-AP3660 ........................................................................................B-10
Enterasys Wireless Outdoor WS-AP3660 Installation Guide ixAbout This GuideThe guide describes how to mount and connect cables to the Enterasys Wireless Outdoor Access Point WS-AP3660. In addition, this guide provides information on the product certifications and national approvals for the WS-AP3660. Who Should Use This GuideThis product should be installed and serviced by a qualified licensed technician, electrician, or electrical maintenance person familiar with its operation and the hazards involved. Proper installation, which includes wiring, mounting, fusing or other over current protection and grounding, can reduce the chance of electric shocks, fires, or explosion in this product or products used within this product.How to Use This GuideRead through this guide completely to familiarize yourself with its contents and to gain an understanding of the features and capabilities of the WS-AP3660. A general working knowledge of data communications networks is helpful when setting up this module.This preface provides an overview of this guide, and a brief summary of each chapter; defines the conventions used in this document; and instructs how to obtain technical support from Enterasys Networks. To locate information about various subjects in this guide, refer to the following table.Note: This guide does not provide information on configuration of the Enterasys Wireless Outdoor APs. For information on how to configure the Enterasys Wireless Outdoor APs, see the Enterasys Wireless Convergence Software User Guide.Electrical Hazard: Only qualified personnel should install or service this unit.Riesgo Electrico: Nada mas personal capacitado debe de instalar o darle servicio a esta unida.Elektrischer Gefahrenhinweis: Installationen oder Servicearbeiten sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden.For...  Refer to...An overview of the WS-AP3660 features. Chapter 1, IntroductionInstructions to mount the WS-AP3660, attach antennas, connect cables, and connect power. Instructions are also included to mount and connect the WS-AP3660 Power Supply. Chapter 2, InstallationSpecifications, environmental requirements, and physical properties of the WS-AP3660 and WS-AP3660 Power Supply. Appendix A, SpecificationsRegulatory certifications and national approvals. Appendix B, Regulatory Information
Related Documentsx About This GuideRelated DocumentsThe manuals listed below can be obtained from the World Wide Web in Adobe Acrobat Portable Document Format (PDF) at the following site:https://extranet.enterasys.com/downloads/•Enterasys Wireless AP External Antenna Site Preparation and Installation Guide•Enterasys Wireless Convergence Software User GuideTypographical ConventionsThe following typographical conventions and icons are used in this document.blue type Indicates a hypertext link. When reading this document online, click the text in blue to go to the referenced figure, table, or section.Lowercase x Indicates the general use of an alphanumeric character (for example, 6x1xx, the x’s indicate a combination of numbers or letters).Note: Calls the reader’s attention to any item of information that may be of special importance.Caution: Contains information essential to avoid damage to the equipment.Precaución: Contiene información esencial para prevenir dañar el equipo.Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.Warning: Warns against an action that could result in personal injury or death.Advertencia: Advierte contra una acción que pudiera resultar en lesión corporal o la muerte.Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar Todesfällen führen können!Electrical Hazard: Warns against an action that could result in personal injury or death.Riesgo Electrico: Advierte contra una acción que pudiera resultar en lesión corporal o la muerte debido a un riesgo eléctrico.Elektrischer Gefahrenhinweis: Warnung vor sämtlichen Handlungen, die zu Verletzung von Personen oder Todesfällen – hervorgerufen durch elektrische Spannung – führen können!
Getting HelpEnterasys Wireless Outdoor WS-AP3660 Installation Guide xiGetting HelpFor additional support related to the WS-AP3660 or this document, contact Enterasys Networks using one of the following methods:Before contacting Enterasys Networks for technical support, have the following data ready:• Your Enterasys Networks service contract number• A description of the failure• A description of any action(s) already taken to resolve the problem (for example, changing mode switches or rebooting the unit)• The serial and revision numbers of all involved Enterasys Networks products in the network• A description of your network environment (such as layout, cable type, other relevant environmental information)• Network load and frame size at the time of trouble (if known)• The device history (for example, if you have returned the device before, or if this is a recurring problem)• Any previous Return Material Authorization (RMA) numbersWorld Wide Web www.enterasys.com/support/ Phone 1-800-872-8440 (toll-free in U.S. and Canada) or 1-978-684-1000For the Enterasys Networks Support toll-free number in your country:www.enterasys.com/support/Internet mail support@enterasys.comTo expedite your message, please type [Wireless] in the subject line.
Getting Helpxii About This Guide
Enterasys Wireless Outdoor WS-AP3660 Installation Guide 1-11IntroductionThis chapter provides general information about the Enterasys Wireless Outdoor Access Point WS-AP3660.WS-AP3660 OverviewThe WS-AP3660 (see Figure 1-1 on page 1-2) enables you to extend your wireless LAN beyond the boundaries of indoor locations. They are resistant to harsh outdoor conditions and extreme temperatures. Using the advanced full mesh wireless distribution feature of the Enterasys wireless LAN, the AP3660 can extend your wireless LAN to outdoor locations without Ethernet cabling. A mounting bracket is available to enable quick and easy mounting of the AP3660 to walls, rails, and poles.The WS-AP3660 is an 802.11n AP that supports 802.11a/802.11g and 802.11b legacy devices. It is delivered in a rugged enclosure. The WS-AP3660 supports a variety of antennas, providing range and coverage versatility. The AP3660 interoperates fully with the Enterasys wireless LAN, including support for Enterasys wireless VoWLAN, branch office mode, availability and mobility features.For information about... Refer to page...WS-AP3660 Overview 1-1WS-AP3660 LED Indicators 1-3Antennas 1-4External Antenna Connectors 1-4Console Port 1-4LAN Port 1-4Reset Switch 1-5Temperature Sensor 1-5Heater Circuit 1-5
WS-AP3660 Overview1-2 IntroductionFigure 1-1  WS-AP3660 Front ViewThe following views (see Figure 1-2 and Figure 1-3) illustrate the connections to the WS-AP3660. Figure 1-2  WS-AP3660 Top View Note: The Enterasys Wireless Outdoor APs do not work without the Enterasys Wireless Controller.1Radio 2 - Left Antenna 3Radio 1 - Middle Antenna2Radio 1 - Left Antenna 4Radio 1 - Right Antenna
WS-AP3660 OverviewEnterasys Wireless Outdoor WS-AP3660 Installation Guide 1-3Figure 1-3  WS-AP3660 Bottom ViewWS-AP3660 LED IndicatorsThe WS-AP3660 provides four LED indicators (see Figure 1-3). The LEDs provide status information (see Table 1-1 on page 1-4) on the current state of the WS-AP3660. For more information, see the Enterasys Wireless Controller Convergence Software User Guide.1Radio 2 - Middle Antenna 5Reset Switch212V DC Connector 6Console Port (RJ45)3Status LEDs 7LAN Port (RJ45)4Radio 2 - Right AntennaNote: The WS-AP3660 provides six external antenna ports. The network administrator determines which antenna port will be used based on the external antenna selected. The WS-AP3660 can also be configured to select the antenna that provides the best possible data transmission (diversity).
WS-AP3660 Overview1-4 IntroductionAntennasThe WS-AP3660 includes external antennas for wireless communications. The WS-AP3660 can transmit from multiple antennas at the same time, as defined with MIMO operation, but the antennas must be selected manually based on customer requirements and coverage area. For a list of external antennas, refer to Appendix B, WS-AP3660 Approved External Antennas.External Antenna ConnectorsThe WS-AP3660 supports six external antenna connections for both 2.4GHz and 5GHz radios. These antennas offer a variety of options for extending the radio range and shaping the coverage area. For a list of external antennas, refer to Appendix B, WS-AP3660 Approved External Antennas.Console PortThe WS-AP3660 includes a single console port (see Figure 1-3 on page 1-3). This port is used to connect a console device to the WS-AP3660 through a serial cable. The console device can be a PC or workstation running a VT-100 terminal adapter emulator, or a VT-100 terminal.LAN PortThe WS-AP3660 has one 10/100/1000BaseT RJ45 LAN port (see Figure 1-3 on page 1-3) that can be attached directly to a 10/100/1000BaseT LAN segment. This segment must conform to the IEEE 802.3 or 802.3u specifications. The WS-AP3660 appears as an Ethernet node and performs a bridging function by moving packets from the wired LAN to remote workstations on the wireless infrastructure.Table 1-1 WS-AP3660 LED Status IndicatorsLED Status Description1 (Power) On Green Indicates the WS-AP3660 is working normally.Flashing Green Indicates:• running a self test• loading software programOn Red Indicates a CPU or system failure.2 (Ethernet Link) On Blue  Indicates a valid 1Gbps Ethernet link.On Green Indicates a valid 100Mbps Ethernet link.On Red Indicates a valid 10Mbps Ethernet link.3 (Wireless Link) On Green Indicates Radio 1 (5GHz) is enabled.Flashing Green Indicates the WS-AP3660 is transmitting or receiving data.4 (Wireless Link) On Green Indicates Radio 2 (2.4GHz) is enabled.Flashing Green Indicates the WS-AP3660 is transmitting or receiving data.
WS-AP3660 OverviewEnterasys Wireless Outdoor WS-AP3660 Installation Guide 1-5Reset SwitchThe WS-AP3660 provides a Reset Switch (see Figure 1-3 on page 1-3) to reset or restore factory default configurations. If you hold down the button for less than 5 seconds, the WS-AP3660 performs a hardware reset. If you hold the button down for 5 seconds or more, any configuration changes are removed, and the factory default configuration are restored to the WS-AP3660.Audible BuzzerThe WS-AP3660 includes an audible buzzer used for aligning an antenna with a remote AP. The volume of the buzzer changes based on signal strength and the position of the antenna. The sound (beep) is followed by a pause where the pause is shorter for higher signal strength and longer for a weak signal.Temperature SensorThe WS-AP3660 includes an internal temperature sensor for monitoring the temperature of the PCB. If the WS-AP3660 temperature changes (either too low or too high), an alert is generated and written to the log file for the AP. The sensor monitors the AP internal temperature, and creates the alert when the temperature enters either zone. For more information on the operating temperatures of the WS-AP3660, refer to Appendix A, Specifications. • A low alarm zone is when the internal temperature is less than 5 degrees above the heater circuit system on temperature (see Heater Circuit below). In this zone the temperature is too close to powering off the unit.• A high alarm is when the temperature rises above 60 Degrees C. In this zone, the CPU may overheat and stop operating.Heater CircuitThe WS-AP3660 provides a heater and thermostat circuit which automatically engages/disengages when the internal PCB temperature reaches between -40 to 0C. The heater maintains a constant operating temperature for optimal performance and reliability.Note: The LAN port also supports power over Ethernet (PoE) based on the IEEE 802.3at standard. Refer to “Power Connections” on page 2-11, for information on supplying power to the WS-AP3660 network port from a network device, such as a switch, that provides Power over Ethernet (PoE).Note: For more information on how to position the WS-AP3660 antennas using the audible buzzer, refer to the Enterasys Wireless AP External Antenna Site Preparation and Installation Guide. This document is available in Adobe Acrobat Portable Document Format (PDF) at the following site: https://extranet.enterasys.com/downloads/Warning: The Enterasys Wireless Outdoor AP buzzer volume reaches volumes between 80 and 90 db. Sustained exposure above 90 db may result in hearing loss.Warning: Do not operate the WS-AP3660 with the Temperature Sensor disconnected as this may cause the unit to fail prematurely.
WS-AP3660 Overview1-6 Introduction
Enterasys Wireless Outdoor WS-AP3660 Installation Guide 2-12InstallationThis chapter provides installation instructions for the Enterasys Wireless Outdoor Access Point WS-AP3660 and the optional WS-AP3660 Power Supply. Package ContentsThe WS-AP3660 package includes components necessary for installation.Unpacking the WS-AP3660Unpack the WS-AP3660 as follows:1. Open the box and remove the packing material protecting the WS-AP3660.2. Verify that the contents of the carton contains the items listed in Table 2-1. .For information about... Refer to page...Package Contents 2-1Separately Ordered Components 2-2WS-AP3660 Installation Procedures 2-3WS-AP3660 Power Supply Installation Procedures 2-11Table 2-1 WS-AP3660 Supplied ComponentsQuantity Item1 WS-AP3660 wireless outdoor access point1 Wall mounting bracket1 Spacer4 M6 screws4 M6 flat washers4 M6 spring washers1 Ground screw6 Terminator caps1 Console port cap2 Stainless steel tie back straps (pole diameters up to 4 inches)
Installation Separately Ordered Components2-23. Perform a visual inspection of the WS-AP3660 for any signs of physical damage. Contact Enterasys Networks if there are any signs of damage. Refer to “Getting Help”  on page xi for details.Unpacking the WS-AP3660 Power SupplyUnpack the WS-AP3660 Power Supply as follows:1. Open the box and remove the packing material protecting the power supply.2. Verify that the contents of the carton contains the items listed in Table 2-2.3. Perform a visual inspection of the power supply for any signs of physical damage. Contact Enterasys Networks if there are any signs of damage. Refer to “Getting Help”  on page xi for details.Separately Ordered ComponentsThe following list of accessories are available for the Enterasys Wireless Outdoor Access Point WS-AP3660. For ordering information, contact your Enterasys sales representative.• Antennas. The following antennas can be used with the WS-AP3660:– WS-AO-2S10360 — Outdoor, 2.4GHz, 10 dBi, Omni Baton (FCC Domain only)– WS-AO-DT05120 — Outdoor, 2.3 - 2.7/4.9 - 6.1GHz, Triple-feed, 5dBi, 120 deg, Sector– WS-AO-5D16060 — Outdoor, 5.15 to 5.875GHz, Dual-polarization, 16dBi, 60 deg, Sector– WS-AO-5D23009 — Outdoor, 5.15 to 5.875GHz, Dual-polarization, 23dBi, 9 deg, Panel1 Waterproof cable gland adapter assembly1 Enterasys Wireless Outdoor AP Quick ReferenceTable 2-1 WS-AP3660 Supplied Components (Continued)Quantity ItemTable 2-2 WS-AP3660 Power Supply ComponentsQuantity Item1 WS-PS3660-MR power supply1 Wall mounting bracket1Spacer4 M5 screws4 M5 flat washers4 M5 spring washers1 Ground screw2 Stainless steel tie back straps (pole diameters up to 4 inches)1 DC to DC cable1 Waterproof AC connector (power cord not supplied)1 Enterasys Wireless Outdoor AP Power Supply Quick Reference
WS-AP3660 Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-3– WS-AIO-2S18018 — Indoor/Outdoor, 2.3 - 2.5GHz, 18dBi, 18 deg, Panel– WS-AO-DS05360 — Outdoor, 2.4 - 2.5/5.15 to 5.875GHz, 5dBI, Omni, Baton– WS-AO-5S10360 — Outdoor, 5GHz, 10dBi, Omni, Baton (FCC Domain only)– WS-AO-DT05120-1 — Outdoor, 2.3 - 2.7/4.9 - 6.1GHz, Triple-feed, 5dBI, 120 deg, Sector– WS-ANT21 — Outdoor, 2.3 - 2.4/5.1 - 5.8GHz, Omni, Baton– WS-AO-DX13025 — Outdoor, 2.4 - 2.5/5.1- 5.9 GHz, Six-feed, 12.5/11.5dBI, 27/30 deg, PanelRefer to “WS-AP3660 Approved External Antennas” on page B-10 and the Enterasys Wireless AP External Antenna Site Preparation and Installation Guide for more information about these antennas. This document is available at: https://extranet.enterasys.com/downloads/.• Power Supply. The following power supply is required for use with the WS-AP3660:– WS-PS3660-MR• Power over Ethernet (PoE) Injector. The following 802.3at PoE injector is recommended for use with the WS-AP3660:– PD-9001GR-ENT (this is an indoor PoE injector)• Terminator cap. This part is listed as a spare item as the WS-AP3660 is shipped with six terminator caps. If you are not attaching six antennas to the WS-AP3660, you must use a terminator cap on the antenna connector not being used.– WS-CAB-RPNTERM — Terminator, Reverse Polarity, Type-N Plug, 50 OHM, 1W• Cables to connect the lightning protectors on the enclosure to the antennas. All cables listed below have Reverse Polarity Type-N plugs at both ends.– WS-CAB-L200C20 (RBTES-L200-C20F) — 20 foot LMR200 cable– WS-CAB-L400C06F (RBTES-L400-C06F) — 6 foot LMR400 cable– WS-CAB-L400C50F (RBTES-L400-C50F) — 50 foot LMR400 cable – WS-CAB-L400C75F (RBTES-L400-C75F) — 75 foot LMR400 cable– WS-CAB-L600C25F (RBTES-L600-C25F) — 25 foot LMR600 cable– WS-CAB-L600C50F (RBTES-L600-C50F) — 50 foot LMR600 cableWS-AP3660 Installation ProceduresThese procedures describes how to attach the mounting bracket to the WS-AP3660, how to mount the WS-AP3660 outside (either a wall or pole), and how to attach the relevant cables. Note: New cable part numbers are listed first. Previous equivalent cable part numbers follow in parentheses.Electrical Hazard: This product should be installed and serviced by a qualified licensed technician, electrician, or electrical maintenance person familiar with its operation and the hazards involved.
Installation WS-AP3660 Installation Procedures2-4Attaching the Mounting BracketTo attach the mounting bracket to the WS-AP3660:1. Determine the desired orientation (vertical or horizontal) of the mounting bracket (see Figure 2-1 on page 2-4).2. Attach the mounting bracket and spacer to the WS-AP3660 using four M6 screws, four spring washers, and four flat washers (see Figure 2-2 on page 2-4).Figure 2-1  Mounting Bracket and Spacer OrientationFigure 2-2  Completed Bracket InstallationHorizontal Bracket Orientation Vertical Bracket Orientation
WS-AP3660 Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-5Mounting the WS-AP3660 to a WallTo attach the WS-AP3660 to a wall:1. Place the WS-AP3660 (with mounting bracket) firmly against the wall surface.2. Secure the WS-AP3660 to the wall with four screws (see Figure 2-3 on page 2-5). Figure 2-3  Mounting the WS-AP3660 to a WallNote: Screws for attaching the WS-AP3660 to a wall are not supplied with the product. The type and length of the screws will depend on the wall type and thickness.
Installation WS-AP3660 Installation Procedures2-6Mounting the WS-AP3660 to a PoleTo fit the mounting plate to a pole:1. Determine the desired mounting orientation of the WS-AP3660 (see Figure 2-4).Figure 2-4  WS-AP3660 Pole Mount Options1Vertical bracket on vertical pole 3Horizontal bracket on horizontal pole2Horizontal bracket on vertical pole
WS-AP3660 Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-72. Feed the supplied stainless steel tie back straps through the openings in the mounting bracket (see Figure 2-5).Figure 2-5  Attaching Straps to the Mounting Bracket3. Feed the free end of the strap around the pole.4. Tighten the tensioning screw to adapt the strap to the diameter of the pole. Attaching AntennasTo attach external antennas to the WS-AP3660:1. Connect an LMR cable (with Reverse Polarity Type-N plugs on both ends) to an antenna connector on the WS-AP3660 (see Figure 1-2 on page 1-2 and Figure 1-3 on page 1-3).2. Connect the antenna to the LMR cable.3. Place a terminator cap on any antenna connector(s) that will not be used (see Figure 2-6 on page 2-8).1Mounting bracket (horizontal position) 2Stainless steel straps (X2)Notes: The total number of required antennas and associated port locations on the WS-AP3660 is dependant on the coverage area and the type of antennas selected.Note: The following antennas do not require an LMR cable and can be directly connected to the WS-AP3660: WS-AO-DT05120-1 and WS-ANT21. See “Separately Ordered Components” on page 2-2, for a complete list of available antennas and cables.
Installation WS-AP3660 Installation Procedures2-8Figure 2-6  Installing Terminator CapsLAN/Console Connections (with Cable Gland Adapter Assembly)The WS-AP3660 has both a LAN and a Console port. Refer to Figure 1-3 on page 1-3 for the location of these ports. Before connecting an RJ45 cable (not provided) to either port, a waterproof cable gland adapter assembly must be installed onto the cable (see Figure 2-7).Figure 2-7  RJ45 Cable Gland Adapter AssemblyInstall the cable gland adapter assembly as follows:1. Insert the RJ45 cable onto the sealing nut.1Terminator cap 2Antenna connector1Sealing nut 2Claw 3Seal 4Main body
WS-AP3660 Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-92. Slide the claw and seal onto the RJ45 cable.3. Screw the main body into the LAN or Console port of the WS-AP3660.4. Plug the RJ45 cable into the LAN or Console port.1Main body 2LAN or Console portCaution: Do not run the network cable through the cable conduit connector used for connecting the power cables. You must connect the network cable and power cables through separate connectors.
Installation WS-AP3660 Installation Procedures2-105. Slide the seal and claw into the main body.6. Secure the seal nut onto the main body.7. Tighten the assembly by hand.
WS-AP3660 Power Supply Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-11Ground Connection1. The ground connection for the WS-AP3660 is located on the rear of the device. Attach a ground to earth cable to one of two grounding terminals using one ground screw (see Figure 2-8).Figure 2-8  WS-AP3660 Grounding TerminalsPower ConnectionsThe WS-AP3660 can be powered in one of the following ways:• Power over Ethernet (PoE)Power is provided to the LAN port of the WS-AP3660 with a PoE injector. The PoE injector must be 802.3at compliant and is not provided with the WS-AP3660.• Power by external power supplyAn external 12VDC power supply (WS-PS3660-MR) can be purchased to power the WS-AP3660. For more information on the installation process, see WS-AP3660 Power Supply Installation Procedures below.WS-AP3660 Power Supply Installation ProceduresThese procedures describe how to attach the mounting bracket to the WS-AP3660 Power Supply, how to mount the power supply outside (either a wall or pole), and how to attach the relevant cables. 1Grounding terminals (2)Note: The RJ45 connector used for providing PoE to the WS-AP3660 must be contained within a waterproof adapter assembly before being installed. For more information, see “LAN/Console Connections (with Cable Gland Adapter Assembly)” on page 2-8.Electrical Hazard: This product should be installed and serviced by a qualified licensed technician, electrician, or electrical maintenance person familiar with its operation and the hazards involved.
Installation WS-AP3660 Power Supply Installation Procedures2-12Attaching the Mounting BracketTo attach the mounting bracket to the WS-AP3660 Power Supply:1. Determine the desired orientation (vertical or horizontal) of the mounting bracket (see Figure 2-9). In the horizontal position, two power supplies can be attached to one bracket.2. Attach the mounting bracket and spacer to the power supply using four M5 screws, four spring washers, and four flat washers (see Figure 2-10).Figure 2-9  Mounting Bracket and Spacer OrientationFigure 2-10  Completed Bracket InstallationHorizontal Bracket Orientation Vertical Bracket Orientation
WS-AP3660 Power Supply Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-13Mounting the Power Supply to a WallTo attach the power supply to a wall:1. Place the power supply firmly against the wall surface. 2. Position the mounting bracket so the mounting holes are aligned with wall studs.3. Secure the power supply to the wall with four screws (see Figure 2-11). Figure 2-11  Mounting the Power Supply to a WallMounting the Power Supply to a PoleTo mount the power supply to a pole:1. Determine the desired mounting orientation of the power supply (see Figure 2-12 on page 2-14).Note: Screws for attaching the power supply to a wall are not supplied with the product. The type and length of the screws will depend on the wall type and thickness.
Installation WS-AP3660 Power Supply Installation Procedures2-14Figure 2-12  Power Supply Pole Mount Options2. Feed the supplied stainless steel tie back straps through the openings in the mounting bracket (see Figure 2-5 on page 2-7).3. Feed the free end of the strap around the pole.4. Tighten the tensioning screw to adapt the strap to the diameter of the pole. Connecting the DC Power Supply to the WS-AP3660To connect the power supply to the WS-AP3660:1. Locate the DC to DC cable (provided with the power supply).2. Insert one end of the DC to DC cable into the DC connector port on the WS-AP3660 (see Figure 1-3 on page 1-3 for the location of the DC connector).3. Screw on and hand tighten the knurled knob securely.4. Insert one end of the DC to DC cable into the DC connector on the bottom of the WS-AP3660 Power Supply (see Figure 2-13 on page 2-15).1Vertical bracket on vertical pole 3Horizontal bracket on horizontal pole2Horizontal bracket on vertical poleNote: The maximum distance between the WS-AP3660 and Power Supply is 1 meter (see Figure 2-14 on page 2-15).
WS-AP3660 Power Supply Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-15Figure 2-13  WS-AP3660 Power Supply Connections5. Screw on and hand tighten the knurled knob securely.Figure 2-14  Power Supply Connections with Drip Loop1AC Power Receptacle 2DC ConnectorNote: The DC to DC cable forms a drip loop that allows water to safely drip away from the connections to both the WS-AP3660 and Power Supply (see Figure 2-14 on page 2-15).11 meter (maximum distance between units)
Installation WS-AP3660 Power Supply Installation Procedures2-16Connecting the Power Supply to AC PowerThe WS-AP3660 Power Supply provides a power receptacle for connecting the unit to an external AC power source. The power supply is shipped with a waterproof AC connector assembly (see Figure 2-15), but a power cord is not provided. Before connecting the power supply to AC power, the AC connector assembly must be installed onto the power cord.Figure 2-15  WS-AP3660 Power Supply AC Connector AssemblyInstall the waterproof connector assembly as follows:1. Strip the power cord sheath.2. Insert the clamp ring and seal into the body.1Sealing nut 3Seal 5Housing assembly2Clamp ring 4Body
WS-AP3660 Power Supply Installation Procedures InstallationEnterasys Wireless Outdoor WS-AP3660 Installation Guide 2-173. Insert the sheathed cable through the sealing nut, clamp ring, seal, and body.4. Insert the cable conductors into the housing assembly using the pin out diagram shown in Figure 2-16.Figure 2-16  Power Cable Pin Out Diagram5. Secure the wires by tightening the single lock nut with a 1.5 mm (Hex) driver.1Pin 1 - Hot 3Pin 3 - Neutral2Pin 2 - Not used 4Pin 4 - Ground1Lock nut
Installation WS-AP3660 Power Supply Installation Procedures2-186. Screw the body into the housing assembly and tighten.7. Screw the sealing nut into the body and tighten.8. Insert the assembled AC connector into the AC power receptacle on the power supply (see Figure 2-13 on page 2-15).9. Screw on and hand tighten the knurled knob securely.10. Insert the plug into the AC power source.This completes the installation of the WS-AP3660.Electrical Hazard: The connection to the AC power source should be made by a properly trained and licensed electrician in accordance with local codes and regulations.
Enterasys Wireless Outdoor WS-AP3660 Installation Guide A-1ASpecificationsThis appendix lists the specifications for the Enterasys Wireless Outdoor Access Point WS-AP3660 and the WS-AP3660 Power Supply.Table A-1 Specifications for the WS-AP3660Item SpecificationEnclosure material Metal enclosure IP67 ratedPower source 802.3at compliant PoE PD12V DC inputPower consumption < 40W (Max.)Outside dimensions (max) 9.8 x 10.23 inches250 x 260 mmAntenna 6x RP-N Jack antenna connectors; 2.4GHz x 3,5GHz x 3,6x antenna terminator capsUplink Interface GbE Ethernet x1 with PoEBuzzer Sound level: >80 dB; <90 dBPause interval: 0.25 to approximately 2 secondsRoHS compliant YesRadio Configuration IEEE 802.11a/b/g/n,2.4/5GHz dual-band; Dual-radio, 3x3 MIMOWater/Dust Proof Ratings NEMA Type 4Operating temperature -40o C to +60o C (includes solar load testingHeater power 24 Watts (PoE deployment)Heater set point temperature System ON = 0o CHeater OFF = 9o C
A-2 SpecificationsTable A-2 Specifications for the WS-AP3660 Power SupplyItem SpecificationEnclosure material Metal enclosure IP67 ratedAC Input 90 to 264VDC output 12VOutside dimensions (max) 8.5 x 4.8 inches215 x 122 mmRoHS compliant YesWater/Dust Proof Ratings NEMA Type 4Operating temperature -40o C to +60o C (includes solar load testing
Enterasys Wireless Outdoor WSAP3660 Installation Guide B-1BRegulatory InformationThis appendix provides regulatory information for the WS-AP3660.WS-AP3660The following regulatory information applies to the WS-AP3660.WS-AP3660 External Antenna APApproved external antennasThe WS-AP3660 must only be used with certified external antennas. Any unused antenna ports must be terminated. For a list of approved external antennas, see “WS-AP3660 Approved External Antennas” on page B-10.United StatesFCC Declaration of Conformity StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:• This device may not cause harmful interference.• This device must accept any interference received, including interference that may cause undesired operation.Warning: Warnings identify essential information. Ignoring a warning can lead to problems with the application.Notes: Specific AP models are only identified in this appendix where it is necessary to do so. Warning: Changes or modifications made to the WS-AP3660s which are not expressly approved by Enterasys could void the user's authority to operate the equipment.Only authorized Enterasys service personnel are permitted to service the system. Procedures that should be performed only by Enterasys personnel are clearly identified in this guide.Note: The WS-AP3660s are in compliance with the European Directive 2002/95/EC on the restriction of the use of certain hazardous substances (RoHS) in electrical and electronic equipment.
WS-AP3660B-2 Regulatory InformationThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential and business environment. This equipment generates, uses, and radiates radio frequency energy, and if not installed and used in accordance with instructions, may cause harmful interference. However, there is no guarantee that interference will not occur. If this equipment does cause harmful interference, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the transmitting antenna.• Increase the separation between the equipment or devices.• Connect the equipment to an outlet other than the receiver's.• Consult a dealer or an experienced radio/TV technician for suggestions.USA Conformance StandardsThis equipment meets the following conformance standards:Safety • UL 60950-1EMC • FCC CFR 47 Part 15, Class BRadio transceiver • CFR 47 Part 15.247, Subpart C (2.4 GHz)• CFR 47 Part 15.407, Subpart E (5 GHz)Other• IEEE 802.11a (5 GHz)• IEEE 802.11b/g (2.4 GHz)• IEEE 802.11n (WS-AP3660)• IEEE 802.3af (PoE)FCC RF Radiation Exposure StatementThe WS-AP3660 complies with FCC RF radiated exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This device has been tested and has demonstrated compliance when simultaneously Warning: The WS-AP3660s must be installed and used in strict accordance with the manufacturer's instructions as described in this guide and related documentation for the device to which the WS-AP3660 is connected. Any other installation or use of the product violates FCC Part 15 regulations.This Part 15 radio device operates on a non-interference basis with other devices operating at the same frequency when using the antennas provided or other Enterasys-certified antennas. Any changes or modifications to the product not expressly approved by Enterasys could void the user's authority to operate this device.For the product available in the USA market, only channels 1 to 11 can be operated. Selection of other channels in the 2.4 GHz band is not possible.
WS-AP3660Enterasys Wireless Outdoor WSAP3660 Installation Guide B-3operated in the 2.4 GHz and 5 GHz frequency ranges. This device must not be co-located or operated in conjunction with any other antenna or transmitter.The radiated output power of the WS-AP3660 is below the FCC radio frequency exposure limits as specified in “Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields” (OET Bulletin 65, Supplement C). This equipment should be installed and operated with a minimum distance of 25 cm between the radiator and your body or other co-located operating antennas.External AntennasThe external antennas used with the WS-AP3660 must be approved and certified before use. However, in order to comply with the local laws and regulations, an approval may be required by the local regulatory authorities.For a list of approved external antennas, see “WS-AP3660 Approved External Antennas” on page B-10.RF safety distanceThe antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with another antenna or transmitter.Professional Installation NoticeTo comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden.CanadaIndustry Canada Compliance StatementThis digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of Industry Canada.Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le materiel brouilleur: “Appareils Numeriques,” NMB-003 edictee par le Industrie Canada.This device complies with Part 15 of the FCC Rules and Canadian Standard RSS-210. Operation is subject to the following conditions: • This device may not cause harmful interference.• This device must accept any interference received, including interference that may cause undesired operation. • This Class B digital apparatus complies with Canadian ICES-003.• Operation in the 5150-5250 MHz band is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems.• Please note that high power radars are allocated as primary users (meaning they have priority) and can cause interference in the 5250-5350 MHz and 5470-5725 MHz bands of LE-LAN devices.• For the product available in the Canadian market, only channels 1 to 11 can be operated. Selection of other channels in the 2.4 GHz band is not possible.
WS-AP3660B-4 Regulatory InformationCanada Conformance StandardsThis equipment meets the following conformance standards:Safety • C22.2 No.60950-1-03EMC • ICES-003, Class BRadio transceiver• RSS-210 (2.4 GHz and 5GHz)Other• IEEE 802.11a (5 GHz)• IEEE 802.11b/g (2.4 GHz)• IEEE 802.11n (WS-AP3660)• IEEE 802.3af (PoE)External AntennasThe external antennas used with the WS-AP3660 must be approved and certified before use. However, in order to comply with the local laws and regulations, an approval may be required by the local regulatory authorities.For a list of approved external antennas, see “WS-AP3660 Approved External Antennas” on page B-10.RF Safety DistanceThe antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with another antenna or transmitter.European CommunityThe WS-AP3660s are designed for use in the European Union and other countries with similar regulatory restrictions where the end user or installer is allowed to configure the WS-AP3660 for operation by entry of a country code relative to a specific country. After the country code is selected, the WS-AP3660 will use the proper frequencies and power outputs for that country code.The WS-AP3660 is intended for outdoor use and must be installed in a proper outdoor location. Contact local Authority for procedure to follow and regulatory information. For more details on legal combinations of frequencies, power levels and antennas, contact Enterasys.Declaration of Conformity with R&TTE Directive of the European Union 1999/5/ECThe following symbol indicates compliance with the Essential Requirements of the R&TTE Directive of the European Union (1999/5/EC).
WS-AP3660Enterasys Wireless Outdoor WSAP3660 Installation Guide B-5Declaration of Conformity in Languages of the European CommunityNew Member States Requirements of Declaration of ConformityEnglish Hereby, Enterasys, declares that this Radio LAN device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.Finnish Valmistaja Enterasys vakuuttaa täten että Radio LAN device tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.Dutch Hierbij verklaart Enterasys dat het toestel Radio LAN device in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Bij deze verklaart Enterasys dat deze Radio LAN device voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.French Par la présente Enterasys déclare que l'appareil Radio LAN device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Par la présente, Enterasys déclare que ce Radio LAN device est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables.Swedish Härmed intygar Enterasys att denna Radio LAN device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Danish Undertegnede Enterasys erklærer herved, at følgende udstyr Radio LAN device overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.German Hiermit erklärt Enterasys die Übereinstimmung des "WLAN Wireless Controller bzw. Access Points" mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 1999/5/EG.Greek ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Enterasys ∆ΗΛΩΝΕΙ ΟΤΙ Radio LAN device ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ ΤΗΣ Ο∆ΗΓΙΑΣ 1999/5/ΕΚ.Icelandic Enterasys lysir her med yfir að thessi bunadur, Radio LAN device, uppfyllir allar grunnkrofur, sem gerdar eru i R&TTE tilskipun ESB nr 1999/5/EC.Italian Con la presente Enterasys dichiara che questo Radio LAN device è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.Spanish Por medio de la presente Enterasys declara que el Radio LAN device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.Portuguese Enterasys declara que este Radio LAN device está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Malti Hawnhekk, Enterasys, jiddikjara li dan Radio LAN device jikkonforma mal-htigijiet essenzjali u ma provvedimenti ohrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.Estonian Käesolevaga kinnitab Enterasys seadme Radio LAN device vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.Hungary Alulírott, Enterasys nyilatkozom, hogy a Radio LAN device megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.Slovak Enterasys týmto vyhlasuje, že Radio LAN device spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES.Czech Enterasys tímto prohlašuje, že tento Radio LAN device je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES."
WS-AP3660B-6 Regulatory InformationEuropean Conformance StandardsThis equipment meets the following conformance standards:Safety • 2006/95/EC Low Voltage Directive (LVD)• IEC/EN 60950-1 + National DeviationsEMC (Emissions / Immunity)• 2004/108/EC EMC Directive• EN 55011/CISPR 11, Class B, Group 1 ISM• EN 55022/CISPR 22, Class B• EN 55024/CISPR 24, includes IEC/EN 61000-4-2,3,4,5,6,11• EN 61000-3-2 and -3-3 (Harmonics and Flicker)• EN 60601-1-2 (EMC immunity for medical equipment)• EN 50385 (EMF)• ETSI/EN 301 489-1 & -17 Radio transceiver • R&TTE Directive 1999/5/EC• ETSI/EN 300 328 (2.4 GHz)• ETSI/EN 301 893 (5 GHz)Other• IEEE 802.11a (5 GHz)• IEEE 802.11b/g (2.4 GHz)• IEEE 802.11n (WS-AP3660)• IEEE 802.3af (PoE)RoHS• European Directive 2002/95/ECSlovenian Šiuo Enterasys deklaruoja, kad šis Radio LAN device atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.Latvian Ar šo Enterasys deklarē, ka Radio LAN device atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiemLithuanian Enterasys deklaruoja, kad Radio LAN device atitinka 1999/5/EC Direktyvos esminius reikalavimus ir kitas nuostatas".Polish Niniejszym, Enterasys, deklaruję, że Radio LAN device spełnia wymagania zasadnicze oraz stosowne postanowienia zawarte Dyrektywie 1999/5/EC.
WS-AP3660Enterasys Wireless Outdoor WSAP3660 Installation Guide B-7External AntennasThe external antennas used with the WS-AP3660 must be approved and certified before use. However, in order to comply with the local laws and regulations, an approval may be required by the local regulatory authorities.For a list of approved external antennas, see “WS-AP3660 Approved External Antennas” on page B-10.RF safety distanceThe antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with another antenna or transmitter.Conditions of use in the European CommunitySome EU countries allow outdoor operation with limitations and restrictions, which are described in this section. It is the responsibility of the end user to ensure operation in accordance with these rules, frequencies, and transmitter power output. The WS-AP3660 must not be operated until properly configured for the customer’s geographic location.Caution: The user or installer is responsible to ensure that the WS-AP3660 is operated according to channel limitations, indoor / outdoor restrictions, license requirements, and within power level limits for the current country of operation. A configuration utility has been provided with the Wireless AP to allow the end user to check the configuration and make necessary configuration changes to ensure proper operation in accordance with the spectrum usage rules for compliance with the European R&TTE directive 1999/5/EC.Caution: Please follow the instructions in this user guide to properly configure the WS-AP3660.• Each Wireless AP is configured with a default group of settings. There is the ability to change these settings. The user or installer is responsible to ensure that each WS-AP3660 is properly configured.• The software within the Wireless AP will automatically limit the allowable channels and output power determined by the selected country code. Selecting the incorrect country of operation or misidentifying the antenna being used,may result in illegal operation and may cause harmful interference to other systems.• This device employs a radar detection feature required for European Community operation in the 5 GHz band. This feature is automatically enabled when the country of operation is correctly configured for any European Community country. The presence of nearby radar operation may result in temporary interruption of operation of this device. The radar detection feature will automatically restart operation on a channel free of radar.• The 5 GHz Turbo Mode feature is not enabled for use on the WS-AP3660s.• The 5150- 5350 MHz band, channels 36, 40, 44, 48, 52, 56, 60, or 64, are restricted to indoor use only.• The external antenna APs must only use antennas that are certified by Enterasys.• The 2.4 GHz band, channels 1 - 13, may be used for indoor or outdoor use but there may be some channel restrictions.• In Greece and Italy, the end user must apply for a license from the national spectrum authority to operate outdoors.• In France, outdoor operation is not permitted using the 2.4 - 2.454 GHz band.
WS-AP3660B-8 Regulatory InformationEuropean Spectrum Usage RulesThe AP configured with approved internal or external antennas can be used for indoor and outdoor transmissions throughout the European community as displayed in Table B-1. Some restrictions apply in Belgium, France, Greece, and Italy.Table B-1 European Spectrum Usage RulesCountry5.15-5.25 (GHz) Channels: 36,40,44,485.25-5.35 (GHz)Channels: 52,56,60,645.47-5.725 (GHz)Channels: 100,104,108,112,116,132,136,1402.4-2.4835 (GHz)Channels: 1 to 13(Except Where Noted)Austria Indoor only Indoor only Indoor or outdoor Indoor or outdoorBelgium Indoor only Indoor only Indoor or outdoor * Indoor or outdoorBulgaria Indoor only Indoor only Indoor or outdoor Indoor or outdoorCroatia Indoor only Indoor only Indoor or outdoor Indoor or outdoorCyprus Indoor only Indoor only Indoor or outdoor Indoor or outdoorCzech Rep. Indoor only Indoor only Indoor or outdoor Indoor or outdoorDenmark Indoor only Indoor only Indoor or outdoor Indoor or outdoorEstonia Indoor only Indoor only Indoor or outdoor Indoor or outdoorFinland Indoor only Indoor only Indoor or outdoor Indoor or outdoorFrance Indoor only Indoor only Indoor or outdoor Indoor onlyGermany Indoor only Indoor only Indoor or outdoor Indoor or outdoorGreece Indoor only Indoor only Indoor (Outdoor w/License) Indoor (Outdoor w/license)Hungary Indoor only Indoor only Indoor or outdoor Indoor or outdoorIceland Indoor only Indoor only Indoor or outdoor Indoor or outdoorIreland Indoor only Indoor only Indoor or outdoor Indoor or outdoorItaly Indoor only Indoor only Indoor or outdoor Indoor (Outdoor w/license)Latvia Indoor only Indoor only Indoor or outdoor Indoor or outdoorLiechtenstein Indoor only Indoor only Indoor or outdoor Indoor or outdoorLithuania Indoor only Indoor only Indoor or outdoor Indoor or outdoorLuxembourg Indoor only Indoor only Indoor or outdoor Indoor or outdoorMalta Indoor only Indoor only Indoor or outdoor Indoor or outdoorNetherlands Indoor only Indoor only Indoor or outdoor Indoor or outdoorNorway Indoor only Indoor only Indoor or outdoor Indoor or outdoorPoland Indoor only Indoor only Indoor or outdoor Indoor or outdoorPortugal Indoor only Indoor only Indoor or outdoor Indoor or outdoorRomania Indoor only Indoor only Indoor or outdoor Indoor or outdoorSlovak Rep. Indoor only Indoor only Indoor or outdoor Indoor or outdoorSlovenia Indoor only Indoor only Indoor or outdoor Indoor or outdoorSpain Indoor only Indoor only Indoor or outdoor Indoor or outdoor
Certifications of Other CountriesEnterasys Wireless Outdoor WSAP3660 Installation Guide B-9Certifications of Other Countries The WS-AP3660s have been certified for use in various other countries. Once the correct country code is selected, the Wireless AP automatically uses the proper frequencies and power outputs for that country code.It is the responsibility of the end user to select the proper country code for the country the device will be operated within or run the risk violating local laws and regulations.Approved External AntennasThe external antenna WS-AP3660s can also be used with certified external antennas. However, in order to comply with the local laws and regulations, an approval may be required by the local regulatory authorities.For a list of approved external antennas, see “WS-AP3660 Approved External Antennas” on page B-10.Other Country Specific Compliance Standards, Approvals and Declarations• IEC 60950-1 CB Scheme + National Deviations• AS/NZS 60950.1 (Safety)• AS/NZS 3548 (Emissions via EU standards – ACMA)• AS/NZS 4288 (Radio via EU standards)• EN 300 328 (2.4 GHz)• EN 301 893 (5 GHz)• EN 301 489-1 & -17 (RLAN)• IEEE 802.11a (5 GHz)• IEEE 802.11b/g (2.4 GHz)• IEEE 802.11n (AP3630, WS-AP3660)• IEEE 802.3af (PoE)Sweden Indoor only Indoor only Indoor or outdoor Indoor or outdoorSwitzerland Indoor only Indoor only Indoor or outdoor Indoor or outdoorTurkey Indoor only Indoor only Indoor or outdoor Indoor or outdoorU.K Indoor only Indoor only Indoor or outdoor Indoor or outdoorTable B-1 European Spectrum Usage Rules (continued)Country5.15-5.25 (GHz) Channels: 36,40,44,485.25-5.35 (GHz)Channels: 52,56,60,645.47-5.725 (GHz)Channels: 100,104,108,112,116,132,136,1402.4-2.4835 (GHz)Channels: 1 to 13(Except Where Noted)Note: * Belgium requires notifying the spectrum agency if deploying > 300 meter wireless links in outdoor public areas.
Certifications of Other CountriesB-10 Regulatory InformationWS-AP3660 Approved External AntennasThe WS-AP3660 external antenna APs can be used with certified external antennas. However, in order to comply with the local laws and regulations, an approval may be required by the local regulatory authorities. The optional antennas listed in Table B-2 have been tested and approved for use with the external antenna models.This device has been designed to operate with the optional antennas listed below, and having a maximum gain of 23 dB. Antennas not included in this list or having a gain greater than 23 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms.To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p) is not more than that required for successful communication.RF Safety DistanceThe antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with another antenna or transmitter.Table B-2 List of Approved Antennas - WS-AP3660Model Application Shape Gain (dBi) Frequency (MHz) Connector TypeWS-AO-DS05360 outdoor omni baton 5 2400-25005150 - 58751 x Reverse Type-N Jack on 12” pigtailWS-AO-2S10360 outdoor omni baton 10 2400 1 x Reverse Type-N JackWS-AO-DT05120 outdoor 120 deg, sector, triple-feed, MIMO5 2300-27004900 - 61003 x Reverse Type-N JackWS-AO-5S10360 outdoor omni baton 10 5000 1 x Reverse Type-N JackWS-AO-5D16060 outdoor 60 degree, sector, dual polarization16 5150-5875 2 x Reverse Type-N JacksWS-AO-5D23009 outdoor 9 degree, panel, dual polarization, point-to-point23 5150-5875 2 x Reverse Type-N JacksWS-AIO-2S18018 indoor/outdoor 18 degree, panel 18 2300-2500 1 x Reverse Type-N JackWS-AO-DT05120-1 outdoor 120 deg, sector, triple-feed5 2300-27004900 - 61003 x Reverse Type-N Plugs on 12” pigtailWS-ANT21 outdoor omni baton 5 2300-24005150 - 58751 x Reverse Type-N PlugWS-AO-DX13025 outdoor panel 12.511.52400-25005100 - 59006 x Reverse Type-N Plugs

Navigation menu