INSTALLATIONPage 1 of 11OBID® classic-proID CPR.03-VP/AB-AMultitag Reader Data/Clock
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 2 of 11Note© Copyright 2006 byFEIG ELECTRONIC GmbHLange Strasse 4D-35781 Weilburg-WaldhausenTel.: +49 6471 3109-0http://www.feig.deWith the edition of this document, all previous editions become void. Indications made in this manual may bechanged without previous notice.Copying of this document, and giving it to others and the use or communication of the contents thereof areforbidden without express authority. Offenders are liable to the payment of damages. All rights are reservedin the event of the grant of a patent or the registration of a utility model or design.Composition of the information in this manual has been done to the best of our knowledge. FEIGELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in thismanual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.The installation instructions given in this manual are based on advantageous boundary conditions. FEIGELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in thismanual  and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH doesnot convey any license under its patent rights nor the rights of others.OBID® and OBID i-scan® is a registered trademark of FEIG ELECTRONIC GmbH.my-d® is a registered trademark of Technologies AGI-CODE® and mifare® is a registered trademark of Philips Electronics N.V.Tag-itTM is a registered trademark of Texas Instruments Incorporated
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 3 of 11Contents1 Safety Instructions / Warning - Read before start-up ! 42 Introduction 43 Technical Specifications 5Dimensions ..................................................................................................................................63.2 Approval.........................................................................................................................64 Installation 74.1 Mounting ........................................................................................................................74.2 Connection.....................................................................................................................84.3 Configuration.................................................................................................................94.3.1 Default Configuration....................................................................................................94.3.2 Reloading the configuration.........................................................................................95 Normal Operating Mode 105.1 Digital Inputs................................................................................................................105.2 Data-/Clock Interface...................................................................................................115.3 Asynchronous Interface: RS232-TTL ........................................................................116 System Delivery Contents 11
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 4 of 111  Safety Instructions / Warning - Read before start-up !• The device may only be used for the intended purpose designed by for themanufacturer.• The operation manual should be conveniently kept available at all times for each user.• Unauthorized changes and the use of spare parts and additional devices which have notbeen sold or recommended by the manufacturer may cause fire, electric shocks orinjuries. Such unauthorized measures shall  exclude any liability by the manufacturer.• The liability-prescriptions of the manufacturer in the issue valid at the time of purchaseare valid for the device. The manufacturer shall  not be held legally responsible forinaccuracies, errors, or omissions in the manual or automatically set parameters for adevice or  for an incorrect application of a device.• Repairs may only be executed by the manufacturer.• Installation, operation, and maintenance procedures should only be carried out byqualified personnel.• Use of the device and its installation must be in accordance with national legalrequirements and local electrical codes .• When working on devices the valid safety regulations must be observed.• Special advice for carriers of cardiac pacemakers:Although this device doesn't exceed the valid limits for electromagnetic fields youshould keep a minimum distance of 25 cm between the device and your cardiac pace-maker and not stay in an immediate proximity of the device respective the antenna forsome time.2 IntroductionThe Multitag-Reader ID CPR.03-VP/AB-A is designed for access control and time-recording sys-tems. Via the configurable data-/clock interface it can connected easily with usual access controland time-recording controllers.The ID CPR.03-VP/AB-A could read the serial-no. (UID) of the most common 13,56 MHz Trans-ponder according ISO 14443 type A, ISO 14443 type B and ISO 15693.The ID CPR.03-VP/AB-A is designed to be wall-mounted onto flat and non-conductive walls with orwithout a flush-mounting box.The data-/clock interface could configured like Wiegand- or magnetic stripe format (ISO7811-2,5 Bit).The configuration could changed while installation with a ConfigCard transponder. This ConfigCardcould prepared comfortable before Installation with a separate tool.
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 5 of 113  Technical SpecificationsHousing Plastic ABS (sealed-in electronics)Color gray - beigeWeight approx. 170 gProtection class IP 65Power Supply 9 - 15 V DCPower Consumption max. 2,6 WTemperature range OperatingStorage-25 °C to +60 °C-40 °C to +85 °CRelative humidity 95% (not condensing)Antenna internalOperating Frequency 13,56 MHzTransmitting power 200 mW ± 2 dBSupported Transponder(read UID)• ISO14443A:e.g. mifare® Standard, mifare® UltraLight, mifare® DESfire,Smart MX, my-d® proximity, SLE44R35S, SLE55R.., etc.• ISO14443B:e.g. SLE66CL, ST19XR34, etc.• ISO15693:e. g. my-d vicinity, I•Code SLI, TagIT HFI, STM LRI512, etc.Connecting cable 50 cm, LiYY 12 * 0,23 mm2 / AWG24Signal Transmitter 1 x LED red1 x LED green1 x BeeperDigital Inputs 1 x switches LED red1 x switches LED green1 x switches Beeper1 x Hold FunctionInterface 1. Data/Clock Emulation:- Magnetic Stripe (ISO7811-2, 5 Bit)- Wiegand2.  RS232-TTL (for Service only)Flash In-circuit firmware update possibleApplicable Standards:• RF approval- Europe- USA• EMC• Safety- Low Voltage- Human ExposureEN 300 330FCC  47 CFR Part 15EN 301 489EN 60950EN 50364
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 6 of 113.1 Dimensions3.2 ApprovalWhen properly used this radio equipment conforms to the essential requirements of Article 3 andthe other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2FCC ID: PJMCPR03This device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that maycause undesired operation.Any changes or modifications not expressly approved by the party responsible for compliance void the user's authority to operate the equipment.75 1783,5607,74,2120
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 7 of 114 InstallationThe ID CPR.03-VP/AB-A is designed to be wall-mounted with or without a 60 mm flush-mountingbox4.1  Mounting•  The reader should not be mounted directly onto conductive materials, such as metal surfaces,metal frames (reinforcement) or metal-plated surfaces, as these surfaces will reduce thereader's range. The clearance to such surfaces should be at least 30 mm.•  The distance between readers of the same design should not be less than 50 cm.•  Before final installation, the planned installation site should be checked for suitability.•  Only install the reader after successful commissioning. The power supply must be discon-nected for configuration (see also : 4.3 Configuration).•  Use the screws provided (3.2 x 25 mm) for installation on 60 mm DIN flush-mounting boxes.•  For other installation methods use 3 mm countersunk-head screws to DIN 963 or with a coun-tersunk head max. diameter of head 5.6 mm.TOPAssembling Disassembling
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 8 of 114.2 ConnectionColour Function Descriptionred Vcc  (+9 to +15 V DC)black GND* Power Supplygreen Data / Data0white Clock / Data1violet CLS / Card PresentClock/Data interface(magnetic strip/ Wiegand)grey LED greenbrown LED rotyellow Beeperblue Holddigital input**pink RS232-TTL (Rx)red / blue RS232-TTL (Tx) Service -Interfacegrey / pink - N.C. -*) If the power is not supplied via the controller the power supply GND must be connectedto the controller GND.**) The digital inputs may only be wired to ground. Wiring to an external power supply maydestroy the input.ControllerVccData / Data0Clock / Data1CLSLED greenLED redBeeperHoldGNDredgreenwhitevioletgreybrownyellowblueblackpinkred/blue+9..15 V DCmax. 150 m
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 9 of 114.3 ConfigurationConfiguration is carried out by means of a ConfigCard. An ISO 15693 transponder can be used asConfigCard (e.g. Infineon my-d, SFR55V10P, Philips I-CODE SLI, etc.)The configuration data are stored in a specified read/write data block on the transponder. Thetransponder is also provided with identifiers which enable recognition as the ConfigCard.The creation and modification of a ConfigCard could be done the FEConfigCardTool which is available forWindows operating systems.4.3.1 Default ConfigurationThe factory configuration of the reader is as follows:• Reads serial numbers (UID) of ISO 14443 Type A, ISO 14443 Type B and ISO 15693 trans-ponders.• Data output: Magstripe Track II, binary (80-bit) format.4.3.2  Reloading the configuration1.  Switch on the power supply.2.  Hold the ConfigCard in the reading range during the configuration phase (8 seconds). Duringthis time the red and green LEDs flash alternately.3.  After the configuration is complete the reader automatically switches back to normal mode.Signals:The reader acknowledges a ConfigCard with the following signals:1 x LED green + Beeper (1 s) ⇒ OKConfigCard has been processed, reader is operating with the new configuration3 x LED rot + Beep ⇒ FaultConfigCard Identifier is not read correctly.⇒ Repeat procedure.⇒ Check the ConfigCard for correct programming.Note:ConfigCards with incorrect AFI are not recognized by the reader. No signaling ispossible
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 10 of 115  Normal Operating ModeIdle State (no Transponder detected):In idle state the reader is searching permanent for a Transponder.red LED = activeTransponder detected:After a Transponder is detected by the ID CPR.03-VP/AB-A the data's are transmitted viadata-/clock interface once and the beeper sounds for a short time. At the same time thered LED turns off for timeout time which is configured (default configuration 2 sec.).To transmit the data's a second time the Transponder must leave the detection field of theID CPR.03-VP/AB-A for more then 1,5 seconds.UID Length ErrorIf the Transponder UID is shorter than configured in ID CPR.03-VP/AB-A a length error issignalized with 2 short beeps. In this case no data's are transmitted via data-/clock inter-face.5.1 Digital InputsLED red:Activates the red LED, as long as the input is connected to GND.LED green:Activates the green LED and deactivates the red LED, as long as the input is connected toGND.Beeper:Activates the beeper LED, as long as the input is connected to GND.Hold:Will not accept a transponder, as long as the input is connected to GND.
OBID®  classic-pro Installation ID CPR.03-VP/AB-AFEIG ELECTRONIC GmbH Page 11 of 115.2 Data-/Clock InterfaceDepending on the reader configuration the hexadecimal coded UID (max. 10 byte) of the Trans-ponder could be transmitted in different formats via data-/clock interface.Details are described in ID CPR.03-VP/AB-A Manual (Document No: H60100-#e-ID-B)5.3 Asynchronous Interface: RS232-TTLThe RS232-TTL Interface is designed only for firmware update. The firmware is stored in a flashchip. The firmware is updated via the serial RS232 (TTL) reader port.The red and green LED is active during the firmware update process.The firmware update is described in ID CPR.03-VP/AB-A Manual (Document No: H60100-#e-ID-B)6   System Delivery Contents1 x housing base including sealed-in electronics1 x housing cover1 x accessory bag (2 screws 3,2x 25 mm)1 x Mounting Instruction