Feig Electronic MRU200 UHF Reader User Manual M70201 0de ID B

Feig Electronic GmbH UHF Reader M70201 0de ID B

Contents

Installation Manual

Download: Feig Electronic MRU200 UHF Reader User Manual M70201 0de ID B
Mirror Download [FCC.gov]Feig Electronic MRU200 UHF Reader User Manual M70201 0de ID B
Document ID882642
Application IDM6wiO8yNI2F7n1i7EeyI9Q==
Document DescriptionInstallation Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.92kB (349040 bits)
Date Submitted2007-12-21 00:00:00
Date Available2007-12-21 00:00:00
Creation Date2007-12-20 14:11:31
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2007-12-20 14:11:31
Document TitleMicrosoft Word - M70201-0de-ID-B.doc
Document CreatorPScript5.dll Version 5.2
Document Author: wennrich

OBID i-scan
®
MONTAGE
INSTALLATION
ID ISC.MRU200
MidRange Reader UHF
(deutsch / english)
final
public (B)
2007-12-20
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
ENGLISH
deutsche Version ab Seite 3
english version from page 30
FEIG ELECTRONIC GmbH
Seite 2 von 53
M70201-0de-ID-B.doc
Montage
ID ISC.MRU200
DEUTSCH
OBID i-scan®
Hinweis
© Copyright 2007 by
FEIG ELECTRONIC GmbH
Lange Straße 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0
http://www.feig.de
Alle früheren Ausgaben verlieren mit dieser Ausgabe ihre Gültigkeit.
Die Angaben in diesem Dokument können ohne vorherige Ankündigung geändert werden.
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht
gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle
Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten.
Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen.
FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung für die Richtigkeit und Vollständigkeit der Angaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht für Folgeschäden auf
Grund fehlerhafter oder unvollständiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bemühungen nie vollständig vermeiden lassen, sind wir für Hinweise jederzeit dankbar.
Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingungen aus. FEIG ELECTRONIC GmbH übernimmt keine Gewähr für die einwandfreie Funktion in systemfremden Umgebungen.
FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthaltenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem
Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte.
OBID® und OBID i-scan® ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH
FEIG ELECTRONIC GmbH
Seite 3 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
Inhalt
Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
Leistungsmerkmale
2.1
Verfügbare Readertypen...............................................................................................7
2.2
Lieferumfang..................................................................................................................7
Montage
3.1
Kabelverschraubungen.................................................................................................8
3.2
Dichtverschlüsse...........................................................................................................9
3.3
Deckelhalter ...................................................................................................................9
3.4
Designblenden.............................................................................................................10
Anschlussklemmen und -buchsen
11
4.1
Versorgungsspannung ...............................................................................................12
4.2
Antennenanschlüsse ..................................................................................................13
4.3
Schnittstellen ...............................................................................................................14
4.3.1 RS232-Schnittstelle.......................................................................................................14
4.3.2 RS485- / RS422-Schnittstelle (ID ISC.MRU200-USB) ..................................................15
4.3.3 Ethernet-Schnittstelle (ID ISC.MRU200-E)....................................................................16
4.3.4 USB-Schnittstelle (ID ISC.MRU200-USB).....................................................................17
4.4
Eingänge ......................................................................................................................17
4.5
Ausgänge .....................................................................................................................19
4.5.1 Optokoppler...................................................................................................................19
4.5.2 Relais ............................................................................................................................20
Bedien- und Anzeigeelemente
5.1
21
LEDs .............................................................................................................................21
FEIG ELECTRONIC GmbH
Seite 4 von 53
M70201-0de-ID-B.doc
6
Montage
ID ISC.MRU200
5.2
T1: Reset-Taster ..........................................................................................................21
5.3
J1-J8: Schnittstellenkonfiguration.............................................................................22
5.4
X60: Default-Einstellung .............................................................................................23
Technische Daten
6.1
24
Zulassung ....................................................................................................................26
6.1.1 Europa (CE) ..................................................................................................................26
6.1.2 USA (FCC) ....................................................................................................................26
FEIG ELECTRONIC GmbH
Seite 5 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
•
Das Gerät darf nur für den vom Hersteller vorgesehenen Zweck verwendet werden.
•
Beim Aufstellen des Gerätes im Geltungsbereich der FCC 47 CFR Part 15 ist ein
Mindestabstand von 20 cm zwischen Antenne und menschlichem Körper zu gewährleisten.
•
Die Bedienungsanleitung ist zugriffsfähig aufzubewahren und jedem Benutzer auszuhändigen.
•
Unzulässige Veränderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen,
die nicht vom Hersteller des Gerätes verkauft oder empfohlen werden, können Brände,
elektrische Schläge und Verletzungen verursachen. Solche Maßnahmen führen daher zu
einem Ausschluss der Haftung und der Hersteller übernimmt keine Gewährleistung.
•
Für das Gerät gelten die Gewährleistungsbestimmungen des Herstellers in der zum Zeitpunkt
des Kaufs gültigen Fassung. Für eine ungeeignete, falsche manuelle oder automatische
Einstellung von Parametern für ein Gerät bzw. ungeeignete Verwendung eines Gerätes wird
keine Haftung übernommen.
•
Reparaturen dürfen nur vom Hersteller durchgeführt werden.
•
Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gerät dürfen nur von
Elektrofachkräften mit einschlägiger Ausbildung erfolgen.
•
Alle Arbeiten am Gerät und dessen Aufstellung müssen in Übereinstimmung mit den
nationalen elektrischen Bestimmungen und den örtlichen Vorschriften durchgeführt werden.
•
Beim Arbeiten an dem Gerät müssen die jeweils gültigen Sicherheitsvorschriften beachtet
werden.
Besonderer Hinweis für Träger von Herzschrittmachern:
Obwohl dieses Gerät die zulässigen Grenzwerte für elektromagnetische Felder nicht
überschreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gerät und Ihrem
Herzschrittmacher einhalten und sich nicht für längere Zeit in unmittelbarer Nähe des
Geräts bzw. der Antenne aufhalten.
FEIG ELECTRONIC GmbH
Seite 6 von 53
M70201-0de-ID-B.doc
2
Montage
ID ISC.MRU200
Leistungsmerkmale
Der Reader ist für das Lesen von passiven Datenträgern, sogenannten „Smart Labels“, mit einer
Betriebsfrequenz im UHF Bereich entwickelt.
2.1
Verfügbare Readertypen
Folgende Readertypen sind z.Z. verfügbar:
Tabelle 2-1: Verfügbare Readertypen
Readertyp
Beschreibung
ID ISC.MRU200-USB-EU
Reader mit USB-Schnittstelle für Europa
ID ISC.MRU200-E-EU
Reader mit Ethernet-Schnittstelle für Europa
ID ISC.MRU200-USB-FCC
Reader mit USB-Schnittstelle für USA
ID ISC.MRU200-E-FCC
Reader mit Ethernet-Schnittstelle für USA
2.2
Lieferumfang
Folgende Komponenten sind im Lieferumfang enthalten:
1 x Reader ID ISC.MRU200
8 x Kurzschlussbrücke (Jumper)
2 x Dichtverschluss M16
1 x Dichtverschluss M12
1 x Dichtverschluss-Reduzierstück
2 x Designblenden aufsteckbar
2 x Integrierte Deckelhalter
FEIG ELECTRONIC GmbH
Seite 7 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
3
Montage
ID ISC.MRU200
Montage
Der Reader ist für die Montage auf Wänden, auch im Freien, konzipiert. Zur Wandmontage befinden sich im Gehäuse vorgesehene Löcher. Dazu muss das Gehäuse nicht geöffnet werden. (siehe
Bild 3-1).
200 (7.87)
110 (4.33)
182 (7.16)
60 (2.36)
DEUTSCH
OBID i-scan®
Bild 3-1: Gehäuse ID ISC.MRU200 (alle Maße in mm (inch))
3.1
Kabelverschraubungen
Die einzelnen Kabelverschraubungen sind in Tabelle 3-1 aufgelistet:
Tabelle 3-1: Kabelverschraubungen ID ISC.MRU200
KabelVerschraubung
Größe
Klemmbereich
(in mm)
M 16
4,5...10
Anschlusskabel Antenne 1
M 16
4,5...10
Anschlusskabel Antenne 2
M 16
4,5...10
Eingänge / Relais / Ausgänge
M 12
3,5...7
Schnittstelle (seriell)
M 12
3,5...7
Spannungsversorgung
M 25
9...17
Ethernet Interface (nur -E) / USB (nur -A)
FEIG ELECTRONIC GmbH
Beschreibung
Seite 8 von 53
M70201-0de-ID-B.doc
3.2
Montage
ID ISC.MRU200
Dichtverschlüsse
Mit denen im Zubehör beigelegten Dichtverschlüssen können nicht benutzte Kabelverschraubungen verschlossen werden. Nur dann wird auch die Schutzart IP54 erreicht.
Das beigelegte Dichtring-Reduzierstück ist für die Netzwerkanbindung bzw. das USBAnschlusskabel vorgesehen. Das aufgeschlitzte Reduzierstück wird über die Netzwerkleitung bzw.
das USB-Anschlusskabel gelegt und anschließend in der Kabelverschraubung fixiert.
Bild 3-2: Netzwerkanbindung mit Dichtring-Reduzierstück
3.3
Deckelhalter
Mit den beiden Deckelhaltern kann der Deckel an dem Gehäuse fixiert werden. Die Deckelhalter
werden in die dafür vorgesehenen Öffnungen eingesteckt.
Bild 3-3: Deckelhalter
FEIG ELECTRONIC GmbH
Seite 9 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
3.4
Montage
ID ISC.MRU200
Designblenden
Die Designblenden werden nach der Montage des Readers aufgesteckt.
Die Nut an der Längsseite der Blende dient zur Demontage der Blende. Mit einem geeigneten
Schraubendreher kann die Blende entfernt werden.
Bild 3-4: Designblende
FEIG ELECTRONIC GmbH
Seite 10 von 53
M70201-0de-ID-B.doc
4
Montage
ID ISC.MRU200
Anschlussklemmen und -buchsen
In Bild 4-1 und Bild 4-2 sind alle Anschlussklemmen und -buchsen, sowie die Bedien- und Anzeigeelemente für die Readertypen -USB bzw. -E dargestellt.
X1
VDC GND
TxD RxD GND
X8
J8
Z+
Y-
B+
A- GND
J1
X2
X62
OUT2
OUT1
X3
X4
IN2
IN1
X60
ANT2
N0
NC COM
X5
ANT1
T1
V4
V3
V2
K1
V1
X6
Bild 4-1: Anschlussklemmen und -buchsen (Typ -A)
FEIG ELECTRONIC GmbH
Seite 11 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
X1
GND
VDC GND
X7
Bild 4-2: Anschlussklemmen und -buchsen (Typ -E)
4.1
Versorgungsspannung
Die Versorgungsspannung von 12...24 VDC wird an der Klemme X1 angeschlossen. Die Zuleitungslänge zwischen Netzteil und Reader-Modul darf 3 m nicht überschreiten.
Tabelle 4-1: Pinbelegung Versorgungsspannung
Klemme
Kurzzeichen
Beschreibung
X1 / Pin 1
VDC
VDC – Versorgungsspannung (+)
X1 / Pin 2
GND
Ground – Versorgungsspannung (-)
GND
VDC
X1
Bild 4-3: Anschluss der Versorgungsspannung
Bei dem verwendeten Netzteil sollte es sich um eine SELV-Stromquelle begrenzter Leistung handeln. Die Ausgangsleistung des Netzteils sollte min. 15 W betragen.
Hinweis:
Eine Verpolung der Versorgungsspannung kann zur Zerstörung des Gerätes führen.
FEIG ELECTRONIC GmbH
Seite 12 von 53
M70201-0de-ID-B.doc
4.2
Montage
ID ISC.MRU200
Antennenanschlüsse
Der Anschluss der Antennen erfolgt über die SMA-Buchsen ANT1 und ANT2. Das SWR der angeschlossen Antennen mit Kabel darf 1,5:1 nicht überschreiten.
Tabelle 4-2: Antennenanschluss
Anschluss
ANT1, ANT2
Beschreibung
SMA-Buchse für Antennenanschluss
(Eingangsimpedanz 50 Ω)
ANT1
ANT2
Bild 4-4: Antennenanschluss
Hinweis:
Das maximale Anzugsdrehmoment der SMA-Buchsen beträgt 0,45 Nm.
FEIG ELECTRONIC GmbH
Seite 13 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
4.3
Montage
ID ISC.MRU200
Schnittstellen
4.3.1 RS232-Schnittstelle
Der Anschluss der RS232-Schnittstelle erfolgt über X2. Die Übertragungsparameter können per
Softwareprotokoll konfiguriert werden.
Tabelle 4-3: Pinbelegung RS232-Schnittstelle
Klemme
Kurzzeichen
X2 / Pin 1
GND
RS232 – GND
X2 / Pin 2
RxD
RS232 – RxD
X2 / Pin 3
TxD
RS232 – TxD
Beschreibung
Reader
PC
X2 / Pin 1 (GND)
Pin 5
X2 / Pin 2 (RxD)
Pin 3
X2 / Pin 3 (TxD)
Pin 2
X2
DEUTSCH
OBID i-scan®
TxD RxD GND
9-pol. DUB-D-Buchse
PC
Bild 4-5: Verdrahtungsbeispiel für den Anschluss der RS232-Schnittstelle
FEIG ELECTRONIC GmbH
Seite 14 von 53
M70201-0de-ID-B.doc
Montage
ID ISC.MRU200
4.3.2 RS485- / RS422-Schnittstelle (ID ISC.MRU200-USB)
Die zweite asynchrone Schnittstelle kann als RS485 oder RS422 konfiguriert werden (siehe 5.3 J1J8: Schnittstellenkonfiguration ). Der Anschluss der RS485- bzw. RS422-Schnittstelle erfolgt über
X3. Tabelle 4-4 zeigt die Pinnbelegung für die entsprechende Schnittstelle:
Tabelle 4-4: Pinbelegung RS485-/RS422-Schnittstelle
Kurzzeichen
Beschreibung
X3 / Pin 1
GND
RS485/RS422 – GND
X3 / Pin 2
A-
RS485/RS422 – (A -)
X3 / Pin 3
B+
RS485/RS422 – (B +)
X3 / Pin 4
Y-
RS422 – (Y -)
X3 / Pin 5
Z+
RS422 – (Z +)
X3
Klemme
Z+
Y-
B+
A- GND
Bild 4-6: Anschlussbelegung der RS485-/RS422-Schnittstelle
FEIG ELECTRONIC GmbH
Seite 15 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
4.3.3 Ethernet-Schnittstelle (ID ISC.MRU200-E)
Der Reader verfügt über eine integrierte 10/100 base-T Netzwerkschnittstelle mit RJ-45- Anschluss. Der Anschluss erfolgt über X7.
Bei einer strukturierten Verkabelung sollte Kabel der Kategorie 5 verwendet werden. Dies garantiert einen problemlosen Betrieb bei 10 Mbps oder 100 Mbps.
Tabelle 4-5: Pinbelegung Ethernet-Schnittstelle
Klemme
Kurzzeichen
Beschreibung
X7 / Pin 1
TX+
Transmit Data +
X7 / Pin 2
TX-
Transmit Data -
X7 / Pin 3
RX+
Receive Data +
X7 / Pin 4
VETH+
n.c.
X7 / Pin 5
VETH+
n.c.
X7 / Pin 6
RX-
X7 / Pin 7
VETH-
n.c.
X7 / Pin 8
VETH-
n.c.
Receive Data -
Vorraussetzung für den Einsatz des TCP/IP-Protokolls ist, dass jedes Gerät am Netzwerk über
eine eigene IP-Adresse verfügt. Alle Reader verfügen über eine werksseitig voreingestellte
IP-Adresse.
Tabelle 4-6: Standardkonfiguration der Ethernet-Schnittstelle
Netzwerk
Adresse
IP-Adresse
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
Hinweis:
Die Reader müssen nacheinander ans Netzwerk angeschlossen und konfiguriert werden.
Jede IP-Adresse darf nur einmal im Netzwerk vertreten sein. Alternativ kann die Einstellung
über die asynchrone Schnittstelle erfolgen.
FEIG ELECTRONIC GmbH
Seite 16 von 53
M70201-0de-ID-B.doc
Montage
ID ISC.MRU200
4.3.4 USB-Schnittstelle (ID ISC.MRU200-USB)
Der Anschluss der USB-Schnittstelle erfolgt über Buchse X8. Die Belegung ist genormt. Die Datenrate des Readers ist auf 12 Mbit beschränkt (USB Full Speed). Es kann ein Standard-USB-Kabel
verwendet werden.
Hinweis:
Die maximale Länge des USB-Kabels darf 5 m betragen. Längere Kabel sind nicht erlaubt.
4.4
Eingänge
Die Optokopplereingänge an Klemmleiste X5 sind galvanisch von der Reader-Elektronik getrennt
und müssen daher mit einer externen Gleichspannung versorgt werden. Die Eingangs-LEDs der
Optokoppler sind intern mit einem Serienwiderstand Rint von 500 Ω beschaltet.
Tabelle 4-7: Pinbelegung Optokopplereingänge
Klemme
Kurzzeichen
Beschreibung
X5 / Pin 1
IN1+
+ Eingang 1
X5 / Pin 2
IN1-
- Eingang 1
X5 / Pin 3
IN2+
+ Eingang 2
X5 / Pin 4
IN2-
- Eingang 2
X5
Rint
IN2
Rint
IN1
Rext
Uext
Rext
Uext
Bild 4-7: Interne und mögliche externe Beschaltung der Optokopplereingänge
Bei Versorgungsspannungen größer 10 V muss der Eingangsstrom durch einen weiteren externen
Vorwiderstand (siehe Tabelle 4-8) auf max. 20 mA begrenzt werden.
FEIG ELECTRONIC GmbH
Seite 17 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
Tabelle 4-8: Externe Vorwiderstände
Externe Spannung Uext
Benötigter externer
Vorwiderstand Rext
5...10 V
---
11...15 V
270 Ω
16...20 V
560 Ω
21...24 V
820 Ω
Hinweise:
• Die Eingänge sind für eine maximale Eingangsspannung von 24 VDC und einen Eingangsstrom von maximal 20 mA ausgelegt.
• Verpolung oder Überlastung der Eingänge führt zu deren Zerstörung.
• Die Versorgungsspannung des Readers darf nicht zur Ansteuerung der Eingänge verwendet werden, da es ansonsten durch zusätzlich eingestrahlte Störungen zu Einbußen
in der Lesereichweite kommen kann.
FEIG ELECTRONIC GmbH
Seite 18 von 53
M70201-0de-ID-B.doc
4.5
Montage
ID ISC.MRU200
Ausgänge
4.5.1 Optokoppler
Die Transistoranschlüsse, Kollektor und Emitter, der beiden Optokopplerausgänge sind von der
Reader-Elektronik galvanisch getrennt und ohne interne Zusatzbeschaltung an Klemme X4 nach
außen geführt. Die Ausgänge müssen daher mit einer externen Spannung betrieben werden.
Tabelle 4-9: Pinbelegung Optokopplerausgänge
Klemme
Kurzzeichen
Beschreibung
X4 / Pin 1
O1-C
Kollektor – Ausgang 1
X4 / Pin 2
O1-E
Emitter – Ausgang 1
X4 / Pin 3
O2-C
Kollektor – Ausgang 2
X4 / Pin 4
O2-E
Emitter – Ausgang 2
X4
OUT2
OUT1
Bild 4-8: Interne und mögliche externe Beschaltung der Optokopplerausgänge
Hinweise:
• Die Ausgänge sind für max. 24 VDC / 30 mA ausgelegt.
• Verpolung oder Überlastung der Ausgänge führt zu deren Zerstörung.
• Die Ausgänge sind nur zum Schalten ohmscher Lasten vorgesehen.
FEIG ELECTRONIC GmbH
Seite 19 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
4.5.2 Relais
Als Relaisausgang steht an X6 ein Wechsler zur Verfügung.
Tabelle 4-10: Pinbelegung Relaisausgang
Klemme
Kurzzeichen
Beschreibung
X6 / Pin 1
COM
X6 / Pin 2
NC
Öffner
X6 / Pin 3
NO
Schließer
Arbeitskontakt
X6
N0
NC
Uext
COM
Bild 4-9: Interne und mögliche externe Beschaltung des Relaisausgangs
Hinweise:
• Der Relaisausgang ist für max. 24 VDC / 2 A ausgelegt.
• Der Relaisausgang ist nur zum Schalten ohm´scher Lasten vorgesehen. Im Falle einer
induktiven Last sind die Relaiskontakte durch eine externe Schutzbeschaltung zu schützen.
FEIG ELECTRONIC GmbH
Seite 20 von 53
M70201-0de-ID-B.doc
OBID i-scan®
5.1
ID ISC.MRU200
DEUTSCH
Montage
Bedien- und Anzeigeelemente
LEDs
In Tabelle 5-1 sind die Konfigurationen der einzelnen LEDs aufgelistet:
Tabelle 5-1: Konfiguration der LEDs
Kurzzeichen
Beschreibung
"RUN-LED 1"
LED V1 (grün)
Signalisiert den ordnungsgemäßen Ablauf der
internen Reader-Software
Diagnose 1: RF-Kommunikation / EEPROM-Status
LED V2 (blau)
Signalisiert durch ein kurzes Blinken die fehlerfreie Kommunikation
mit einem Transponder auf der RF-Schnittstelle
Blinkt abwechselnd mit V1 nach dem Reset im Anschluss an ein
Software-Update
Blinkt abwechselnd mit V1 falls nach einem Reset ein Datenfehler
beim Lesen der Parameter auftrat
Diagnose 2: Host-Kommunikation
LED V3 (gelb)
Signalisiert durch ein kurzes Blinken das Senden eines Protokolls an
den Host
Diagnose 3: RF-Warnung
LED V4 (rot)
5.2
Leuchtet bei einem Fehler im RF-Teil des Readers. Der Fehlertyp
kann per Software über die Schnittstellen ausgelesen werden
T1: Reset-Taster
Durch Betätigen des Tasters T1 wird am Reader ein Reset durchgeführt.
FEIG ELECTRONIC GmbH
Seite 21 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
5.3
Montage
ID ISC.MRU200
J1-J8: Schnittstellenkonfiguration
Über die Jumper J7 – J8 kann die asynchrone Schnittstelle als RS485- oder RS422-Schnittstelle
konfiguriert werden.
Tabelle 5-2: Konfiguration der RS485-/RS422-Schnitstelle
Jumper
RS485
RS422
J7
geschlossen
offen
J8
geschlossen
offen
Es können die eventuell benötigten Abschlusswiderstände mit den Jumpern J1 bis J6 zugeschaltet
werden.
Tabelle 5-3: Abschlusswiderstände der RS485/RS422
Jumper
Geschlossen
offen
J1
Pull-Up an RS4xx -B
ohne Pull-Up an RS4xx -B
J2
Pull-Down an RS4xx -A
ohne Pull-Down an RS4xx -A
J5
Abschlusswiderstand
RS4xx -A ⇔ RS4xx -B
ohne Abschlusswiderstand
RS485 -A ⇔ RS485 -B
J3
Pull-Up an RS422 -Z
ohne Pull-Up an RS422 -Z
J4
Pull-Down an RS422 -Y
ohne Pull-Down an RS422 -Y
J6
Abschlusswiderstand
RS422 -Y ⇔ RS422 -Z
ohne Abschlusswiderstand
RS422 -Y ⇔ RS422 -Z
500 Ohm
J1
J8
J1
500
RS422 Z+
120 Ohm
J7
500
J3
RS485 +
120
J6
RS422 YRS422 B+
J5
J2
RS485 J4
500 Ohm
Bild 5-1: Jumper der RS485-Schnittstelle
FEIG ELECTRONIC GmbH
120
J5
RS422 A500
J2
500
Bild 5-2: Jumper der RS422-Schnittstelle
Seite 22 von 53
M70201-0de-ID-B.doc
5.4
Montage
ID ISC.MRU200
X60: Default-Einstellung
Die Stiftleiste X60 kann mit einem Jumper (Rastermaß 2,0 mm) kurzgeschlossen werden. In
Tabelle 5-4 ist die Funktion der Stiftleiste X60 beschrieben.
Tabelle 5-4: Stiftleiste X60
X60
Beschreibung
offen
keine Auswirkung
kurzgeschlossen
nach Betätigen des Tasters T1 wird die Werkseinstellung des Readers
wieder eingestellt.
Hinweis:
Alle vorgenommen Einstellungen gehen nach Betätigung des Tasters T1 in Verbindung mit
kurzgeschlossener Stiftleiste X60 verloren.
FEIG ELECTRONIC GmbH
Seite 23 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
Montage
ID ISC.MRU200
Technische Daten
Mechanische Daten
• Gehäuse
Aluminium Druckguss, pulverbeschichtet,
verschließbarer Klappdeckel
• Abmessungen (B x H x T)
200 x 110 x 60 mm³
• Gewicht
1,1 kg
• Schutzart
IP 54
• Farbe
RAL 7040 (ähnlich Fenstergrau)
Elektrische Daten
• Spannungsversorgung
12...24 VDC ± 5 %
Noise Ripple : max. 150 mV
• Leistungsaufnahme
max. 15 VA
• Betriebsfrequenz
865,6...867,6 MHz (EN 302 208)
902...928 MHz (FCC CFR 47 Part 15.247)
• Sendeleistung
100...300 mW (100 mW Step – Software)
• Modulationsgrad
20...40% und 100%
(per Software einstellbar)
• Empfänger
Datenraten 40 kbps, 64 kbps, 80 kbps
• Antennenanschlüsse
- 2 x gemultiplext
2 x SMA Buchse (50 Ω)
• Ausgänge:
- 2 Optokoppler
- 1 Relais (1 x Wechsler)
24 VDC / 30 mA (galvanisch getrennt)
24 VDC / 2 A
• Eingänge
- 1 Optokoppler
• Schnittstellen
FEIG ELECTRONIC GmbH
max. 24 VDC / 20 mA
- RS232
- RS485 / RS422 (wahlweise einstellbar)
- Ethernet (TCP/IP) (ID ISC.MRU200-E)
- USB (ID ISC.MRU200-A)
Seite 24 von 53
M70201-0de-ID-B.doc
Montage
ID ISC.MRU200
• Protokoll Modi
- FEIG ISO Host
- Buffer Reader Mode
(Data Filtering and buffering)
- Scan Mode
• Unterstützte Transponder
- EPC class 1 Gen 2
- 18000-6-B
(UpgradeCode notwendig)
• Signalgeber optisch
4 LEDs zur Diagnose des Betriebszustandes
• Multi-Reader-Betrieb
Synchronisation der Luftprotokolle durch Verwendung der Reader Synchronisation
Umgebungsbedingungen
• Temperaturbereich
- Betrieb
- Lagerung
• Vibration
• Schock
-25...+55°C
-25...+85°C
EN60068-2-6
10...150 Hz :
0,075 mm / 1 g
EN60068-2-27
Beschleunigung : 30 g
Angewendete Normen
• Zulassung Funk
- Europa
- USA
• EMV
EN 302 208
FCC 47 CFR Part 15
EN 301 489
• Sicherheit
- Niederspannung
- Human Exposure
FEIG ELECTRONIC GmbH
EN 60950
EN 50364
Seite 25 von 53
M70201-0de-ID-B.doc
DEUTSCH
OBID i-scan®
DEUTSCH
OBID i-scan®
6.1
Montage
ID ISC.MRU200
Zulassung
6.1.1 Europa (CE)
Die Funkanlage entspricht, bei bestimmungsgemäßer Verwendung den grundlegenden Anforderungen des Artikels 3 und den übrigen einschlägigen Bestimmungen der R&TTE Richtlinie
1999/5/EG vom März 99.
Equipment Classification gemäß ETSI EN 302 208 und ETSI EN 301 489: Class 2
6.1.2 USA (FCC)
To meet the Part 15 of the FCC Rules the reader ID ISC.MRU200 must operate with the
FEIG Antenna ID.ISC.ANT.U250/250-FCC.
FCC ID: PJMMRU200
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
NOTICE:
Changes or modifications made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
FEIG ELECTRONIC GmbH
Seite 26 von 53
M70201-0de-ID-B.doc
Montage
ID ISC.MRU200
DEUTSCH
OBID i-scan®
FEIG ELECTRONIC GmbH
Seite 27 von 53
M70201-0de-ID-B.doc
Montage
ID ISC.MRU200
DEUTSCH
OBID i-scan®
FEIG ELECTRONIC GmbH
Seite 28 von 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
ENGLISH
Note
© Copyright 2007 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this manual has been done to the best of our knowledge.
FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The installation instructions given in this manual are based on advantageous boundary conditions.
FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.
OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
FEIG ELECTRONIC GmbH
Page 30 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
Safety Instructions / Warning - Read before start-up !
33
Features of the Reader Family ID ISC.MRU200
34
2.1
Available Reader Types ..............................................................................................34
2.2
Scope of delivery.........................................................................................................34
Installation
35
3.1
Cable Glands ...............................................................................................................35
3.2
Seal Caps .....................................................................................................................36
3.3
Cover stays ..................................................................................................................36
3.4
Decorative Covers .......................................................................................................37
Terminals and Jacks
38
4.1
Supply Voltage.............................................................................................................39
4.2
Antenna Connections .................................................................................................40
4.3
Interfaces .....................................................................................................................41
4.3.1 RS232 Interface ............................................................................................................41
4.3.2 RS485 / RS422 Interface (ID ISC.MRU200-USB).........................................................42
4.3.3 Ethernet Interface (ID ISC.MRU200-E) .........................................................................43
4.3.4 USB Interface (ID ISC.MRU200-USB) ..........................................................................44
4.4
Inputs............................................................................................................................44
4.5
Outputs.........................................................................................................................46
4.5.1 Optocouplers .................................................................................................................46
4.5.2 Relay .............................................................................................................................47
Operating and Display Elements
5.1
48
LEDs .............................................................................................................................48
FEIG ELECTRONIC GmbH
Page 31 of 53
M70201-0de-ID-B.doc
ENGLISH
Contents
OBID i-scan®
ENGLISH
Installation
ID ISC.MRU200
5.2
Reset Button ................................................................................................................48
5.3
J1-J8: Interface configuration ....................................................................................49
5.4
X60: Default Settings...................................................................................................50
Technical Data
6.1
51
Approval .......................................................................................................................53
6.1.1 Europe (CE) ..................................................................................................................53
6.1.2 USA (FCC) ....................................................................................................................53
FEIG ELECTRONIC GmbH
Page 32 of 53
M70201-0de-ID-B.doc
OBID i-scan®
ID ISC.MRU200
Safety Instructions / Warning - Read before start-up !
•
The device may only be used for the intended purpose designed by for the manufacturer.
•
When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation
of 20 cm (8 inch) between antenna and the human body must be maintained.
•
The operation manual should be conveniently kept available at all times for each user.
•
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
•
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
•
Repairs may only be executed by the manufacturer.
•
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
•
Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
•
When working on devices the valid safety regulations must be observed.
Special advice for wearers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should
keep a minimum distance of 25 cm (10 inch) between the device and your cardiac pacemaker and not stay in the immediate proximity of the device’s antenna for any length of
time.
FEIG ELECTRONIC GmbH
Page 33 of 53
M70201-0de-ID-B.doc
ENGLISH
Installation
OBID i-scan®
Installation
ID ISC.MRU200
Features of the Reader Family ID ISC.MRU200
ENGLISH
The Reader has been developed for reading passive data carriers, so-called „Smart Labels“, using
an operating frequency in the UHF range.
2.1
Available Reader Types
The following Readers are currently available:
Table 2-1: Available Reader types
Reader type
Description
ID ISC.MRU200-USB-EU
Reader with USB Interface for Europe
ID ISC.MRU200-E-EU
Reader with Ethernet Interface for Europe
ID ISC.MRU200-USB-FCC
Reader with USB Interface for USA
ID ISC.MRU200-E-FCC
Reader with Ethernet-Interface for USA
2.2
Scope of delivery
The following components are included in the scope of delivery:
1 x Reader ID ISC.MRU200
8 x jumper
2 x seal cap M16
1 x seal cap M12
1 x seal cap - reducer
2 x decorative cover, clip-on
2 x integrated cover stays
FEIG ELECTRONIC GmbH
Page 34 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
Installation
The Reader is designed for wall mount, including outdoors. Holes are provided in the housing for
wall attachment. The housing does not need to be opened for installation on a wall (see Fig. 3-1).
200 (7.87)
110 (4.33)
60 (2.36)
ENGLISH
182 (7.16)
Fig. 3-1: Housing ID ISC.MRU200 (all dimensions in mm (inch))
3.1
Cable Glands
The different cable glands are shown in Table 3-1.
Table 3-1: ID ISC.MRU200 cable glands
Cable gland
Size
Clamping Range
in mm (inch)
M 16
4,5...10 (0.18...0.39)
Antenna Cable 1
M 16
4,5...10 (0.18...0.39)
Antenna Cable 2
M 16
4,5...10 (0.18...0.39)
Inputs / Relay / Outputs
M 12
3,5...7 (0.14...0.28)
Interface (serial)
M 12
3,5...7 (0.14...0.28)
Supply voltage
M 25
9...17 (0.35...0.67)
Ethernet Interface (Model –E only)
USB Interface (Model –USB only)
FEIG ELECTRONIC GmbH
Page 35 of 53
Description
M70201-0de-ID-B.doc
OBID i-scan®
3.2
Installation
ID ISC.MRU200
Seal Caps
The seal caps included in the scope of delivery can be used to close off unused cable fittings. This
is necessary for reaching the IP54 class.
ENGLISH
The reducing ring provided is intended for the network connection. The slotted reducer is placed
over the network cable and then fixed in place in the cable gland.
Fig. 3-2: network connection with slotted reducer
3.3
Cover stays
The two cover stays can be used to attach the cover to the housing. The cover stays are inserted
into the openings provided for this purpose.
Fig. 3-3: Cover stay
FEIG ELECTRONIC GmbH
Page 36 of 53
M70201-0de-ID-B.doc
OBID i-scan®
3.4
Installation
ID ISC.MRU200
Decorative Covers
The decorative covers are attached after installing the Reader.
ENGLISH
The slot on the long side of the cover is used for disassembling the cover. Use a screwdriver to
remove the cover.
Fig. 3-4: Decorative cover
FEIG ELECTRONIC GmbH
Page 37 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
Terminals and Jacks
Fig. 4-1 and Fig. 4-2 show terminals, jacks and operating elements of reader type -USB respectively reader type -E.
X1
TxD RxD GND
X8
J8
Z+
Y-
B+
A- GND
J1
X2
X62
OUT2
OUT1
X3
X4
IN2
IN1
X60
ANT2
N0
NC COM
X5
ANT1
T1
V4
V3
V2
K1
V1
X6
ENGLISH
VDC GND
Fig. 4-1: Terminals, jacks and operating elements of Type -USB
FEIG ELECTRONIC GmbH
Page 38 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
X1
GND
VDC GND
4.1
Supply Voltage
Connect the 12...24 VDC supply voltage to Terminal X1. The cable length between the power
supply and the Reader module must not exceed 3m (118 inch).
Table 4-1: Supply voltage pin assignments
Terminal
Abbreviation
Description
X1 / Pin 1
VDC
Vcc – supply voltage (+)
X1 / Pin 2
GND
Ground – supply voltage (-)
GND
VDC
X1
Fig. 4-3: Connecting the supply voltage
The power supply should be a Safety Extra-Low Voltage (SELV) type with limited power. The output power of the power supply should be at least 15 W.
Note:
Reversing the polarity of the supply voltage may destroy the unit.
FEIG ELECTRONIC GmbH
Page 39 of 53
M70201-0de-ID-B.doc
ENGLISH
X7
Fig. 4-2: Terminals, jacks and operating elements of Type -E
OBID i-scan®
4.2
Installation
ID ISC.MRU200
Antenna Connections
The external antennas are connected to the SMA jacks ANT1 and ANT2. The SWR of the connected antennas with the cables should not be worse than 1.5:1.
ENGLISH
Table 4-2: Antenna Connections ANT1 and ANT2
Connections
ANT1, ANT2
Description
SMA jacks for antenna connections
(input impedance 50 Ω)
ANT1
ANT2
Fig. 4-4: Antenna Connections ANT1 and ANT2
Note:
The maximum tightening torque of the SMA sockets is 0,45 Nm (4.0 lbf in).
FEIG ELECTRONIC GmbH
Page 40 of 53
M70201-0de-ID-B.doc
OBID i-scan®
4.3
Installation
ID ISC.MRU200
Interfaces
The RS232 interface is connected on X2. The transmission parameters can be configured by
means of software protocol.
Table 4-3: RS232 interface pinouts
Abbreviation
X2 / Pin 1
GND
RS232 – GND
X2 / Pin 2
RxD
RS232 – RxD
X2 / Pin 3
TxD
RS232 – TxD
X2
Terminal
Description
Reader
PC
X2 / Pin 1 (GND)
Pin 5
X2 / Pin 2 (RxD)
Pin 3
X2 / Pin 3 (TxD)
Pin 2
TxD RxD GND
9-pol. DUB-D-Buchse
PC
Fig. 4-5: Wiring example for connecting the RS232 interface
FEIG ELECTRONIC GmbH
Page 41 of 53
M70201-0de-ID-B.doc
ENGLISH
4.3.1 RS232 Interface
OBID i-scan®
Installation
ID ISC.MRU200
4.3.2 RS485 / RS422 Interface (ID ISC.MRU200-USB)
The second asynchronous interface can be configured for RS485 or RS422 (see 5.3 J1-J8: Interface configuration). The RS485 interface respectively RS422 interface is connected to X3.
Terminal
Abbreviation
Description
X3 / Pin 1
GND
RS485 / RS422 – GND
X3 / Pin 2
A-
RS485 / RS422 – (A -)
X3 / Pin 3
B+
RS485 / RS422 – (B +)
X3 / Pin 4
Y-
RS422 – (Y -)
X3 / Pin 5
Z+
RS422 – (Z +)
X3
ENGLISH
Table 4-4: RS485 / RS422 interface pinouts
Z+
Y-
B+
A- GND
Fig. 4-6: Wiring the RSR485 / RS422 interface
FEIG ELECTRONIC GmbH
Page 42 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
4.3.3 Ethernet Interface (ID ISC.MRU200-E)
ENGLISH
The Reader has an integrated 10 / 100 base-T network port for an RJ45. Connection is made on
X7. With structured cabling Cat 5 cables should be used. This ensures reliable operation at
10 Mbps or 100 Mbps.
Table 4-5: Ethernet interface pinouts
Terminal
Abbreviation
Description
X7 / Pin 1
TX+
Transmit Data +
X7 / Pin 2
TX-
Transmit Data -
X7 / Pin 3
RX+
Receive Data +
X7 / Pin 4
VETH+
n.c.
X7 / Pin 5
VETH+
n.c.
X7 / Pin 6
RX-
X7 / Pin 7
VETH-
n.c.
X7 / Pin 8
VETH-
n.c.
Receive Data -
The prerequisite for using TCP/IP protocol is that each device has a unique address on the network. All Readers have a factory set IP address..
Table 4-6: Standard configuration of the Ethernet connection
Network
Address
IP-Address
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
Note:
The readers must be connected to the network and configured one after the other. Every IPAddress must be used only one time. Alternatively this configuration can be done with the
asynchronous interface.
FEIG ELECTRONIC GmbH
Page 43 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
4.3.4 USB Interface (ID ISC.MRU200-USB)
The USB socket on the board is terminal X8. The pinout is standardized. The data rate is reduced
to 12 Mbit (USB full speed). A standard USB-cable can be used.
ENGLISH
Note:
The length of the USB-cable can be a max. of 5m (20 inch). It is not allowed to use longer
cables.
4.4
Inputs
The optocoupler inputs in Terminal X5 are galvanically isolated from the Reader electronics and
must therefore be externally supplied. The input LEDs for the optocouplers are switch internally
with a series resistor Rint of 500 Ω.
Table 4-7: Optocoupler input pin assignments
Terminal
Abbreviation
Description
X5 / Pin 1
IN1+
+ Input 1
X5 / Pin 2
IN1-
- Input 1
X5 / Pin 3
IN2+
+ Input 2
X5 / Pin 4
IN2-
- Input 2
X5
Rint
IN2
Rint
IN1
Rext
Uext
Rext
Uext
Fig. 4-7: Internal and possible external wiring of the optocoupler inputs
For supply voltages of greater than 10 V the input current must be limited to max. 20 mA by an
additional external series resistor (see Table 4-8).
FEIG ELECTRONIC GmbH
Page 44 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
External voltage Uext
Required external series
resistor Rext
5...10 V
---
11...15 V
270 Ω
16...20 V
560 Ω
21...24 V
820 Ω
Notes:
• The inputs are configured for a maximum input current of 24 VDC and an input current
of maximum 20 mA.
• Reversing the polarity or overloading the inputs will destroy them.
• The Reader supply voltage must not be used to drive the inputs, since otherwise
additionally induced noise may reduce the effective reading range.
FEIG ELECTRONIC GmbH
Page 45 of 53
M70201-0de-ID-B.doc
ENGLISH
Table 4-8: External Series Resistor
OBID i-scan®
4.5
Installation
ID ISC.MRU200
Outputs
ENGLISH
4.5.1 Optocouplers
The transistor connections of the two optocoupler outputs, collector and emitter, are galvanically
isolated from the Reader electronics and brought out with no internal circuitry to terminal X4. The
outputs must therefore be powered with an external power supply.
Table 4-9: Optocoupler output pin configuration
Terminal
Abbreviation
Description
X4 / Pin 1
O1-C
Collector – Output 1
X4 / Pin 2
O1-E
Emitter – Output 1
X4 / Pin 3
O2-C
Collector – Output 2
X4 / Pin 4
O2-E
Emitter – Output 2
X4
OUT2
OUT1
Fig. 4-8: Internal and possible external wiring of the optocoupler outputs
Notes:
• The outputs are configured for max. 24 VDC / 30 mA.
• Reversing the polarity or overloading the outputs will destroy them.
• The outputs are intended for switching resistive loads only.
FEIG ELECTRONIC GmbH
Page 46 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
4.5.2 Relay
A changeover relay is provided on terminal X6.
Terminal
Abbreviation
X6 / Pin 1
COM
Working contact
X6 / Pin 2
NC
Normally closed
X6 / Pin 3
NO
Normally open
ENGLISH
Table 4-10: Relay output pinouts
Description
X6
N0
NC
Uext
COM
Fig. 4-9: Internal and possible external wiring of the relay output
Notes:
• The relay outputs are configured for max. 24 VDC / 2 A.
•
The relay outputs are intended for switching resistive loads only. If an inductive load is
used, the relay contacts must be protected by means of an external protection circuit.
FEIG ELECTRONIC GmbH
Page 47 of 53
M70201-0de-ID-B.doc
OBID i-scan®
ENGLISH
5.1
Installation
ID ISC.MRU200
Operating and Display Elements
LEDs
Table 5-1 shows the LED configuration.
Table 5-1: LED configuration
Abbreviation
LED V1 (green)
Description
"RUN-LED 1"
Indicates proper running of the internal Reader software
Diagnostic 1: RF communication / EEPROM status
Short flashing indicates errorless communication with a transponder
on the RF interface
Flashes alternately with V1 after a reset following a software update
Flashes alternately with V1 in case of a data error when reading the
parameters after a reset
LED V2 (blue)
Diagnostic 2: Host communication
LED V3 (yellow)
Short flashing indicates sending of a protocol to the host
Diagnostic 4: RF warning
LED V4 (red)
5.2
Comes on when there is an error in the RF section of the Reader.
The error type can be read out via software over the RS232/RS485
interface
Reset Button
Pressing the button T1 resets the reader.
FEIG ELECTRONIC GmbH
Page 48 of 53
M70201-0de-ID-B.doc
OBID i-scan®
5.3
Installation
ID ISC.MRU200
J1-J8: Interface configuration
Jumpers J7 and J8 are used to configure the asynchronous interface as an RS485 or R422 port.
Jumper
RS485
RS422
J7
closed
open
J8
closed
open
ENGLISH
Table 5-2: Configuration of the RS485 / RS422 port
Any termination resistors needed can be enabled using jumpers J1 through J6.
Table 5-3: Termination resistors for RS485 / RS422
Jumper
closed
open
J1
Pull-Up on RS4xx - B
without Pull-Up on RS4xx - B
J2
Pull-Down on RS4xx - A
without Pull-Down on RS4xx – A
J5
Termination resistor
RS4xx - A ⇔ RS4xx - B
without Termination resistor
RS485 - A ⇔ RS485 - B
J3
Pull-Up on RS422 - Z
without Pull-Up on RS422 - Z
J4
Pull-Down on RS422 - Y
without Pull-Down on RS422 – Y
J6
Termination resistor
RS422 - Y ⇔ RS422 - Z
without Termination resistor
RS422 - Y ⇔ RS422 - Z
500 Ohm
J1
RS485 +
J8
J1
500
RS422 Z+
120 Ohm
J7
500
J3
120
J6
RS422 YRS422 B+
J5
J2
RS485 J4
500 Ohm
Fig. 5-1: RS485 Interface Jumper
FEIG ELECTRONIC GmbH
120
J5
RS422 A500
J2
500
Fig. 5-2: RS422 Interface Jumper
Page 49 of 53
M70201-0de-ID-B.doc
OBID i-scan®
5.4
Installation
ID ISC.MRU200
X60: Default Settings
The pin connector X60 can be closed with a jumper (2.0 mm).
Table 5-4: pin connector X60
ENGLISH
X60
Description
open
no effect
closed
after pressing the button T1 the reader is configured with the default
settings.
Note:
All configured settings are lost after pressing the button while the pin connector X60 is
closed.
FEIG ELECTRONIC GmbH
Page 50 of 53
M70201-0de-ID-B.doc
OBID i-scan®
Installation
ID ISC.MRU200
Technical Data
• Housing
Die-case aluminum, powder coated,
lockable hinged cover
• Dimensions ( W x H x D )
200 x 110 x 60 mm³
(7.9 inch x 4.3 inch x 2.4 inch)
• Weight
approx. 1,1 kg (2.4 lb)
• Enclosure rating
IP 54
• Color
RAL 7040 (similar to window gray)
Electrical Data
• Supply Voltage
12...24 VDC ± 5 %
Noise Ripple : max. 150 mV
• Power Consumption
max. 15 VA
• Operating Frequency
869.525 MHz (EN 300 220)
865.6...867.6 MHz (EN 302 208)
902...928 MHz (FCC CFR 47 Part 15.247)
• Transmitting Power
100...300 mW (100 mW Step – Software)
• Modulation
20...40% and 100%
(software configurable)
• Receiver
Data rates 40 kbps, 64 kbps, 80 kbps
• Antenna Connection
- 2 x multiplexing
2 x SMA socket (50 Ω)
• Outputs:
- 2 Optocouplers
- 1 Relay (1 x Changeover)
24 VDC / 30 mA (galvanically isolated)
24 VDC / 2 A
• Inputs
- 2 Optocouplers
FEIG ELECTRONIC GmbH
max. 24 VDC / 20 mA (galvanically isolated)
Page 51 of 53
M70201-0de-ID-B.doc
ENGLISH
Mechanical Data
ENGLISH
OBID i-scan®
Installation
ID ISC.MRU200
• Interfaces
- RS232
- RS485 / RS422 (selectable)
- Ethernet (TCP/IP) (ID ISC.MRU200-E only)
- USB (ID ISC.MRU200-USB only)
• Protocol modes
- FEIG ISO Host
- Buffer Reader Mode
(Data Filtering and buffering)
- Scan Mode
• Supported Transponders
- EPC class 1 Gen 2
- 18000-6-B
(UpgradeCode required)
• Optical Indicators
4 LEDs for operating status diagnostics
• Multi-Reader Operation
Synchronization of the air protocols using Reader
synchronization
Ambient
• Temperature range
- Operating
- Storage
• Vibration
• Shock
-25...+55°C (-13...+131°F)
-25...+85°C (-13...+185°F)
EN60068-2-6
10...150 Hz :
0.075 mm / 1 g
EN60068-2-27
Acceleration
: 30 g
Applicable Standards
• RF approval
- Europe
- USA
• EMC
EN 302 208 / EN 300 220
FCC 47 CFR Part 15
EN 301 489
• Safety
- Low-Voltage
- Human Exposure
FEIG ELECTRONIC GmbH
EN 60950
EN 50364
Page 52 of 53
M70201-0de-ID-B.doc
OBID i-scan®
ID ISC.MRU200
Approval
6.1.1
Europe (CE)
When properly used this radio equipment conforms to the essential requirements of Article 3 and
the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.
Equipment Classification according to ETSI EN 302 208 and ETSI EN 301 489: Class 2
6.1.2
USA (FCC)
To meet the Part 15 of the FCC Rules the reader ID ISC.MRU200 must operate with the
FEIG Antenna ID.ISC.ANT.U250/250-FCC.
FCC ID: PJMMRU200
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
NOTICE:
Changes or modifications made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
FEIG ELECTRONIC GmbH
Page 53 of 53
M70201-0de-ID-B.doc
ENGLISH
6.1
Installation

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 53
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:3e698537-0002-4fac-9a75-a5325d3f8695
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2007:12:20 14:11:31+01:00
Create Date                     : 2007:12:20 14:11:31+01:00
Document ID                     : uuid:2cd4f738-9462-407d-b6e1-48bf5a9c9a0c
Format                          : application/pdf
Title                           : Microsoft Word - M70201-0de-ID-B.doc
Creator                         : wennrich
Author                          : wennrich
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PJMMRU200

Navigation menu