Document Author: Michael Rödig

OBID i-scan
®
MONTAGE
INSTALLATION
ID ISC.MU02.02
(deutsch / english)
final
public (B)
2010-02-12
M91002-0de-ID-B.doc
Montage
ID ISC.MU02.02
DEUTSCH
OBID® i-scan
ENGLISH
deutsche Version ab Seite 3
english version from page 20
FEIG ELECTRONIC GmbH
Page 2 of 36
M91002-0de-ID-B.doc
Montage
ID ISC.MU02.02
DEUTSCH
OBID® i-scan
Hinweis
© Copyright 2009 by
FEIG ELECTRONIC GmbH
Lange Straße 4
D-35781 Weilburg
Tel.: +49 6471 3109-0
http://www.feig.de
Alle früheren Ausgaben verlieren mit dieser Ausgabe ihre Gültigkeit.
Die Angaben in diesem Dokument können ohne vorherige Ankündigung geändert werden.
Weitergabe sowie Vervielfältigung dieses Dokuments, Verwertung und Mitteilung ihres Inhalts sind nicht
gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlung verpflichtet zu Schadenersatz. Alle
Rechte für den Fall der Patenterteilung oder Gebrauchsmuster-Eintragung vorbehalten.
Die Zusammenstellung der Informationen in diesem Dokument erfolgt nach bestem Wissen und Gewissen.
FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung für die Richtigkeit und Vollständigkeit der Angaben in diesem Dokument. Insbesondere kann FEIG ELECTRONIC GmbH nicht für Folgeschäden auf
Grund fehlerhafter oder unvollständiger Angaben haftbar gemacht werden. Da sich Fehler, trotz aller Bemühungen nie vollständig vermeiden lassen, sind wir für Hinweise jederzeit dankbar.
Die in diesem Dokument gemachten Installationsempfehlungen gehen von günstigsten Rahmenbedingungen aus. FEIG ELECTRONIC GmbH übernimmt weder Gewähr für die einwandfreie Funktion in systemfremden Umgebungen, noch für die Funktion eines Gesamtsystems, welches die in diesem Dokument beschriebenen Geräte enthält.
FEIG ELECTRONIC weist ausdrücklich darauf hin, dass die in diesem Dokument beschriebenen Geräte
nicht für den Einsatz mit oder in medizinischen Geräten oder für Geräte für lebenserhaltende Maßnahmen
konzipiert sind, bei denen ein Fehler eine Gefahr für menschliches Leben oder für die gesundheitliche Unversehrtheit zur Folge haben kann. Der Applikationsdesigner ist dafür verantwortlich geeignete Maßnahmen
zu ergreifen um Gefahren, Schäden oder Verletzungen zu vermeiden.
FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung dafür, dass die in diesem Dokument enthaltenden Informationen frei von fremden Schutzrechten sind. FEIG ELECTRONIC GmbH erteilt mit diesem
Dokument keine Lizenzen auf eigene oder fremde Patente oder andere Schutzrechte.
OBID® und OBID i-scan® ist ein eingetragenes Warenzeichen der FEIG ELECTRONIC GmbH.
FEIG ELECTRONIC GmbH
Page 3 of 36
M91002-0de-ID-B.doc
Montage
ID ISC.MU02.02
Inhalt
1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
2. Leistungsmerkmale des Readermoduls ID ISC.MU02.02
2.1. Leistungsmerkmale.............................................................................................................6
2.2. Verfügbare Readertypen.....................................................................................................6
2.3. Optional erhältlich...............................................................................................................6
3. Montage und Anschluss
3.1. Abmessungen......................................................................................................................7
3.2. Anschluss RS232- und Daten-/Takt-Schnittstelle X2.......................................................8
3.2.1. Spannungsversorgung...................................................................................................9
3.2.2. RS232-Schnittstelle .....................................................................................................10
3.2.3. Daten-/Taktschnittstelle ...............................................................................................11
3.2.4. Abschaltung .................................................................................................................12
3.3. Anschluss USB-Schnittstelle X1......................................................................................12
3.4. Antennenanschluss ..........................................................................................................13
3.5. Anzeigeelemente ...............................................................................................................14
3.6. Montagehinweise ..............................................................................................................15
3.6.1. Metallische Umgebung ................................................................................................15
3.6.2. EMV-Beeinflussung über Zuleitungen .........................................................................16
4. Funkzulassungen
16
4.1. Europa (CE)........................................................................................................................16
4.2. USA (FCC) ..........................................................................................................................17
5. Technische Daten
FEIG ELECTRONIC GmbH
18
Page 4 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
1. Sicherheits- und Warnhinweise - vor Inbetriebnahme unbedingt lesen
•
Das Gerät darf nur für den vom Hersteller vorgesehenen Zweck verwendet werden.
•
Beim Aufstellen des Gerätes im Geltungsbereich der FCC 47 CFR Part 15 ist ein Mindestabstand von 23cm (8inch) zwischen Antenne und menschlichem Körper zu gewährleisten.
•
Die Bedienungsanleitung ist zugriffsfähig aufzubewahren und jedem Benutzer auszuhändigen.
•
Unzulässige Veränderungen und die Verwendung von Ersatzteilen und Zusatzeinrichtungen,
die nicht vom Hersteller des Gerätes verkauft oder empfohlen werden, können Brände, elektrische Schläge und Verletzungen verursachen. Solche Maßnahmen führen daher zu einem
Ausschluss der Haftung und der Hersteller übernimmt keine Gewährleistung.
•
Für das Gerät gelten die Gewährleistungsbestimmungen des Herstellers in der zum Zeitpunkt
des Kaufs gültigen Fassung. Für eine ungeeignete, falsche manuelle oder automatische Einstellung von Parametern für ein Gerät bzw. ungeeignete Verwendung eines Gerätes wird keine
Haftung übernommen.
•
Reparaturen dürfen nur vom Hersteller durchgeführt werden.
•
Anschluss-, Inbetriebnahme-, Wartungs-, und sonstige Arbeiten am Gerät dürfen nur von Elektrofachkräften mit einschlägiger Ausbildung erfolgen.
•
Alle Arbeiten am Gerät und dessen Aufstellung müssen in Übereinstimmung mit den nationalen elektrischen Bestimmungen und den örtlichen Vorschriften durchgeführt werden.
•
Beim Arbeiten an dem Gerät müssen die jeweils gültigen Sicherheitsvorschriften beachtet werden.
•
Besonderer Hinweis für Träger von Herzschrittmachern:
Obwohl dieses Gerät die zulässigen Grenzwerte für elektromagnetische Felder nicht überschreitet, sollten Sie einen Mindestabstand von 25 cm zwischen dem Gerät und Ihrem Herzschrittmacher einhalten.
FEIG ELECTRONIC GmbH
Page 5 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
2. Leistungsmerkmale des Readermoduls ID ISC.MU02.02
2.1. Leistungsmerkmale
Das Readermodul ID ISC.MU02.02 ist für das Lesen und Schreiben von passiven Transpondern,
sogenannten "Smart Labels", mit einer Betriebsfrequenz von 860 - 960 MHz entwickelt worden. Es
eignet sich für alle Anwendungen, bei denen geringe bis mittlere Lesereichweiten bei kleinen Abmessungen des Readers benötigt werden.
Das Modul besitzt 2 integrierte Antennenausgänge, an die jeweils eine externe 50 Ω-Antenne angeschlossen werden kann.
2.2. Verfügbare Readertypen
Folgende Readertypen sind z.Z. verfügbar:
Readertyp
Beschreibung
ID ISC.MU02.02-AD
Readermodul mit RS232- und Daten-/Takt-Schnittstelle, externe Versorgungsspannung von 5 V DC
ID ISC.MU02.02-CU
Readermodul mit RS232-LVTTL- und USB-Schnittstelle, externe Versorgungsspannung von 5 V DC oder über USB
2.3. Optional erhältlich
Folgende Komponenten sind optional erhältlich. Diese Komponenten werden zum Beispiel benötigt, um den Reader ID ISC.MU02.02 an einem COM-Port zu betreiben.
Zubehör:
Bestellnummer:
ID CAB.A-A Adapterkabel für RS232 und Daten/Takt
2259.000.00.00
ID CAB.RS-A Kabel für RS232 und Spannungsversorgung
1690.000.00.00
RS232-TTL Konverter
1962.000.00.00
ID Net.5V Netzteil
1689.000.00.01
ID CAB.USB-B Kabel für USB
3541.000.00.00
ID ISC.ANT.C05-A UHF-Antennenkabel U.FL-U.FL 500 mm
3540.000.00.00
ID ISC.ANT.U75/50-EU UHF-Antennenmodul 865 – 868 MHz
3544.000.00.00
ID ISC.ANT.U75/50-FCC UHF-Antennenmodul 902 – 928 MHz
3543.000.00.00
FEIG ELECTRONIC GmbH
Page 6 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
3. Montage und Anschluss
3.1. Abmessungen
Bild 1 zeigt die Maßzeichnung des Readermoduls ID ISC.MU02.02 in mm.
44
50
50
44
3,
Ø
13,4
11,4
Bild 1: Maßzeichnung des Readermoduls ID ISC.MU02.02 in mm
FEIG ELECTRONIC GmbH
Page 7 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
3.2. Anschluss RS232- und Daten-/Takt-Schnittstelle X2
Bild 2 und Tabelle 1 zeigen die Belegung der Anschlussstiftleiste X2. Die Stiftleiste ist für
Flachbandkabelanschluss mittels IDC-Federleiste mit Rastermaß 2,54 mm ausgelegt.
10
Bild 2: Belegung der Anschlussstiftleiste X2
Pin
Kurzzeichen
Beschreibung
DAT
Datenleitung der
Daten-/Taktschnittstelle
CLK
Taktleitung der
Daten-/Taktschnittstelle
TxD
RS232 – Transmit Data
GND **
Masse
RxD
RS232 – Receive Data
SHDN
Abschaltung
CLS
CLS-Leitung der
Daten-/Taktschnittstelle
VCC *
+ 5 V DC
GND **
Masse
10
--
Keine Funktion (NUR offen betreiben!)
**
Nur geregelte DC-Spannungen verwenden !
Die GND-Pins 4 und 9 sind auf dem Readermodul direkt
miteinander verbunden
Tabelle 1: Belegung der Anschlussstiftleiste X2
FEIG ELECTRONIC GmbH
Page 8 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
3.2.1. Spannungsversorgung
Für die Spannungsversorgung des ID ISC.MU02.02 dürfen nur geregelte DC-Spannungen verwendet werden.
Im Falle von getakteten Netzteilen zur Versorgung des Moduls ist auf eine ausreichende Filterung
der Versorgungsspannung zu achten.
Störungen der Versorgungsspannung können sich in einer Reduzierung der Lese- und Schreibreichweite des Modules auswirken.
Die Länge des Zuleitungskabels der Spannungsversorgung sollte möglichst kurz sein. Sie darf 3 m
nicht überschreiten.
X2
Pin-Nr.
Kurzzeichen
Beschreibung
VCC *
+ 5 V DC ± 5%
4, 9
GND **
Masse
**
Nur geregelte DC-Spannungen verwenden !
Die GND-Pins 4 und 9 sind auf dem Readermodul
direkt miteinander verbunden
Tabelle 2: Pinbelegung der Spannungsversorgung an X2
HINWEIS:
• Eine Verpolung der Versorgungsspannung kann zur Zerstörung des Gerätes führen.
• Versorgungsspannungen außerhalb der Spezifikation können zur Zerstörung des Gerätes führen.
FEIG ELECTRONIC GmbH
Page 9 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
3.2.2. RS232-Schnittstelle
Die Länge des Zuleitungskabels der RS232-Schnittstelle sollte möglichst kurz sein. Sie darf 3 m
nicht überschreiten.
X2
Pin-Nr.
Kurzzeichen
4, 9
**
Beschreibung
TxD *
RS232 - Transmit Data
GND **
Masse
RxD *
RS232 - Receive Data
Bezeichnungen der Signale aus Sichtweise des
Readermoduls.
Die GND-Pins 4 und 9 sind auf dem Readermodul
direkt miteinander verbunden
Tabelle 3: Pinbelegung der RS232-Schnittstelle an X2
Die Übertragungsparameter der Schnittstelle können per Softwareprotokoll konfiguriert werden.
Tabelle 4 zeigt die Standardparameter der RS232-Schnittstelle.
Parameter
Standardeinstellung
Baudrate
38400
Anzahl der Datenbits
Parität
Even
Anzahl der Stoppbits
Tabelle 4: Standardparameter der RS232-Schnittstelle.
Hinweis:
•
Wird an einem angeschlossenen PC/Notebook ein USB / RS232-Konverter benutzt, so
sollte der COM-Port Parameter „Char Timeout Multiplier“ von „1“ auf ca. „10“ erhöht
werden.
•
Wird ein RS232 / TTL-Konverter ohne externe Spannungsversorgung benutzt, kann es
notwendig sein das die COM -Port Parameter “RTS” und “DTR” manuell eingeschaltet
werden müssen.
FEIG ELECTRONIC GmbH
Page 10 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
3.2.3. Daten-/Taktschnittstelle
Die Länge des Zuleitungskabels der Daten-/Taktschnittstelle sollte möglichst kurz sein. Sie darf
3 m nicht überschreiten.
X2
Pin-Nr.
Kurzzeichen
DAT
Datenleitung der
Daten-/Taktschnittstelle
CLK
Taktleitung der
Daten-/Taktschnittstelle
CLS
CLS-Leitung der
Daten-/Taktschnittstelle
4, 9
GND *
Masse
Beschreibung
Die GND-Pins 4 und 9 sind auf dem Readermodul
direkt miteinander verbunden
Tabelle 5: Pinbelegung der Daten-/Takt-Schnittstelle an X2
Host
Data
Clock
CLS
GND
DAT
CLK
CLS
GND
ID ISC.MU02
Bild 3: Anschluss der Daten-/Taktschnittstelle
FEIG ELECTRONIC GmbH
Page 11 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
3.2.4. Abschaltung
Mit Hilfe des SHDN-Kontakts (Pin-Nr. 6 an Stiftleiste X2) kann der ID ISC.MU02.02 abgeschaltet
werden. Dafür muss der Kontakt auf Masse gelegt werden.
X2
Pin-Nr. 6
Betriebszustand
nicht verbunden
an
Masse (GND)
aus
Tabelle 6: Zustandstabelle für SHDN-Kontakt
HINWEIS:
• Versorgungsspannungen außerhalb der Spezifikation können zur Zerstörung des Gerätes führen.
3.3. Anschluss USB-Schnittstelle X1
Bild 4 und Tabelle 7 zeigen die Belegung des Anschlusssteckers X1 vom Typ “JST PH” Rastermaß 2 mm (liegend).
Bild 4: Belegung der Anschlussstiftleiste X1
FEIG ELECTRONIC GmbH
Page 12 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
OBID® i-scan
ID ISC.MU02.02
Pin
Kurzzeichen
Beschreibung
SHIELD
Schirmung
GND
Masse
D+
USB-D PLUS
D–
USB-D MINUS
VCC
5 V Spannungsversorgung
DEUTSCH
Montage
Tabelle 7: Belegung der Anschlussstiftleiste X1
Die Stromversorgung des Gerätes erfolgt über die USB-Schnittstelle (Bus-Powered).
Die USB-Schnittstelle muss einen Strom von 500 mA liefern können (High Powered Interface).
Die Datenrate des Readers ist auf 12 Mbit beschränkt (USB high speed).
Wird der Reader zum ersten mal über USB in Betrieb genommen, muss er im Betriebssystem des
Computers angemeldet werden. Details entnehmen Sie bitte der Anleitung M70700-xde-ID-B: „Installation OBID® USB-Treiber“.
HINWEIS:
• Wenn der ID ISC.MU02.02 über die USB-Schnittstelle mit Spannung versorgt wird, darf
keine weitere Spannungsquelle an die Stiftleiste X2 angeschlossen werden.
3.4. Antennenanschluss
Über die Antennenbuchsen ANT1 und ANT2 können bis zu 2 Antennen an den ID ISC.MU02.02
angeschlossen werden. Bild 5 zeigt die Position der Antennenbuchsen vom Typ “Hirose U.FL”. Die
Eingangsimpedanz der Buchsen beträgt 50 Ω. Die Antennen können per Software umgeschaltet
werden.
Bild 5: Position der Antennenbuchsen ANT1 und ANT2
FEIG ELECTRONIC GmbH
Page 13 of 36
M91002-0de-ID-B.doc
Montage
ID ISC.MU02.02
3.5. Anzeigeelemente
Das Readermodul ID ISC.MU02.02 besitzt eine rote LED (V1), eine grüne LED (V2) und eine
blaue LED (V3) als Anzeigeelemente (siehe Bild 6).
Bild 6: Position der LED´s
Die Funktionen der beiden LED´s V2 und V3 können per Softwareprotokoll konfiguriert werden.
Ergänzend dazu besteht auch die Möglichkeit alle 3 LED´s direkt durch ein weiteres
Softwareprotokoll anzusteuern.
Tabelle 8 zeigt die Standardeinstellung von V1, V2 und V3.
FEIG ELECTRONIC GmbH
Page 14 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
OBID® i-scan
LED
Farbe
ID ISC.MU02.02
DEUTSCH
Montage
Standardeinstellung
• Blinkt nach einem Reset fünf mal.
V1
Rot
• Leuchtet nicht im Normalbetrieb
• Blinkt im Fehlerfall im Wechsel mit V2
V2
Grün
• Blinkt nach einem Reset fünf mal.
• Leuchtet kontinuierich, bei keiner
Transponderkommunikation
• Leuchtet nicht bei
Transponderkommunikation
• Blinkt im Fehlerfall im Wechsel mit V1
V3
Blau
• Blinkt nach einem Reset zehn mal.
• Leuchtet nach einer erfolgreichen
Kommunikation mit einem Transponder für
1 Sekunde.
Tabelle 8: Standardeinstellung der LED´s
3.6. Montagehinweise
Folgende mögliche Beeinflussungen durch die Umgebung sollten beim Einbau eines ID
ISC.MU02.02 in ein anderes Gerät beachtet werden :
•
Beeinflussung durch eine metallische Umgebung
⇒ Verstimmung der angeschlossenen Antennen
⇒ Beeinträchtigung der Ausbreitung des elektromagnetischen Feldes der Antennen
•
EMV-Beeinflussung über Zuleitungen
⇒ Beeinträchtigung der Kommunikation zwischen Reader und Label
3.6.1. Metallische Umgebung
Beim Einbau eines ID ISC.MU02.02 in ein anderes Gerät ist darauf zu achten, dass sich möglichst
keine Metallflächen bzw. Metallteile in der direkten Umgebung der angeschlossenen Antennen
befinden. Diese können die Antennen verstimmen und die Ausbreitung des elektromagnetischen
Feldes durch Reflexionen beeinträchtigen. Dies führt zu Leselöchern und Überreichweiten.
Der Abstand zwischen Antenne und Metallfläche sollte mindestens 5 cm betragen. Dabei
sollte bedacht werden, dass sich auch andere Leiterplatten, je nach Kupferauflage, wie Metallflächen verhalten.
Ist eine metallische Umgebung nicht zu vermeiden, so sollten die Abstände im Interesse der stabilen Funktion jedoch so groß wie nur irgend möglich gewählt werden.
FEIG ELECTRONIC GmbH
Page 15 of 36
M91002-0de-ID-B.doc
Montage
ID ISC.MU02.02
Auch der Bereich zwischen Antenne und Transponder, sowie der Bereich auf der anderen Seite
des Transponders sollte frei von Metallteilen sein.
3.6.2. EMV-Beeinflussung über Zuleitungen
Trotz der internen EMV-Filter des Readers kann es durch starke Störungen auf der Spannungsversorgung zu Beeinträchtigungen der Kommunikation zwischen Reader und Transponder kommen.
Beim Einbau eines ID ISC.MU02.02 in ein anderes Gerät sollte daher auf eine möglichst saubere,
störfreie Spannungsversorgung geachtet werden.
4. Funkzulassungen
4.1. Europa (CE)
Die Funkanlage entspricht, bei bestimmungsgemäßer Verwendung den grundlegenden Anforderungen des Artikels 3 und den übrigen einschlägigen Bestimmungen der R&TTE Richtlinie
1999/5/E6 vom März 99.
Equipment Classification gemäß ETSI EN 301 489: Class 2
FEIG ELECTRONIC GmbH
Page 16 of 36
M91002-0de-ID-B.doc
DEUTSCH
OBID® i-scan
Montage
ID ISC.MU02.02
DEUTSCH
OBID® i-scan
4.2. USA (FCC)
FCC ID: PJMMU02
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
NOTICE:
Changes or modifications made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
This device is labeled with an FCC ID number.
If this label is not visible when installed in an end device, the outside of the device MUST
also display a label referring to the enclosed module.
Wording on the label similar to the following shall be used:
This device contains transmitter module FCC ID PJMMU02
At the time of this printing, the antennas listed below were the only antennas approved for
use with the ID ISC.MU02.02 module. Use of other antennas must be approved by
FEIG ELECTRONIC GmbH.
Antennas approved:
ID ISC.ANT.U170/170-FCC
ID ISC.ANT.U100/75-FCC
ID ISC.ANT.U75/50-FCC
FEIG ELECTRONIC GmbH
Page 17 of 36
M91002-0de-ID-B.doc
Montage
ID ISC.MU02.02
DEUTSCH
OBID® i-scan
5. Technische Daten
Mechanische Daten
• Abmessungen ( B x H x T )
50 mm x 50 mm x 14 mm
• Gewicht
10 g
• Anschlüsse
• 10-polige Stiftleiste mit Rastermaß 2,54mm
•
5-polige Stiftleiste vom Typ “JST PH” Rastermaß 2 mm (liegend)
Elektrische Daten
• Spannungsversorgung
5 V DC ± 5%
• Leistungsaufnahme
max. 2 W
• Betriebsfrequenz
860 ... 960 MHz
• Sendeleistung
max. 170mW; reduzierbar
• Antennenanschluss
2 Buchsen vom Typ „Hirose U.FL“; 50 Ω; umschaltbar
• Schnittstellen
Variante AD
RS232-V24, Daten-/Takt
Variante CU
RS232-LVTTL, USB
FEIG ELECTRONIC GmbH
Page 18 of 36
M91002-0de-ID-B.doc
Montage
ID ISC.MU02.02
DEUTSCH
OBID® i-scan
Funktionelle Eigenschaften
• Protokoll Modi
- FEIG ISO HOST
- Scan Mode
• Unterstützte Transponder
EPC Class 1 Gen 2
• Signalgeber optisch
3 LED (rot / grün / blau)
Umgebungsbedingungen
• Temperaturbereich
- Betrieb
- Lagerung
• Relative Luftfeuchtigkeit
-25°C to +55°C
-25°C to +85°C
5 bis 95% nicht betauend
Angewendete Normen
• Zulassung Funk
- Europa
- USA
EN 302 208
FCC 47 CFR Part 15
• EMV
EN 301 489
• Sicherheit
EN 60950
FEIG ELECTRONIC GmbH
Page 19 of 36
M91002-0de-ID-B.doc
OBID®
Installation
ID ISC.MU02.02
© Copyright 2009 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge. FEIG
ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments and does not give
any guaranty for the functionality of the complete system which incorporates the subject of this document.
FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed
with components and testing methods for a level of reliability suitable for use in or in connection with surgical
implants or as critical components in any life support systems whose failure to perform can reasonably be
expected to cause significant injury to a human. To avoid damage, injury, or death, the user or application
designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does
not convey any license under its patent rights nor the rights of others.
OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.
FEIG ELECTRONIC GmbH
Page 20 of 36
M91002-0de-ID-B.doc
ENGLISH
Note
OBID®
Installation
ID ISC.MU02.02
6. Safety Instructions / Warning - Read before start-up !
22
7. Performance Characteristics of the ID ISC.MU02.02 Reader Module
23
7.1. Performance Characteristics ...........................................................................................23
7.2. Available module types ....................................................................................................23
7.3. Optional available..............................................................................................................23
8. Installation and wiring
24
8.1. Dimensions ........................................................................................................................24
8.2. Wiring .................................................................................................................................25
8.2.1. Supply voltage .............................................................................................................26
8.2.2. RS232 interface ...........................................................................................................27
8.2.3. Data/Clock interface ....................................................................................................28
8.2.4. Shut Down ...................................................................................................................29
8.3. USB interface.....................................................................................................................29
8.4. Antenna ports ....................................................................................................................30
8.5. Display elements ...............................................................................................................31
8.6. Installation notes...............................................................................................................32
8.6.1. Metallic surroundings...................................................................................................32
8.6.2. EMC effects on cables.................................................................................................33
9. Radio Approvals
33
9.1. Europe (CE)........................................................................................................................33
9.2. USA (FCC) ..........................................................................................................................34
10. Technical Data
FEIG ELECTRONIC GmbH
35
Page 21 of 36
M91002-0de-ID-B.doc
ENGLISH
Contents
OBID®
Installation
ID ISC.MU02.02
•
The device may only be used for the intended purpose designed by for the manufacturer.
•
When installing the device in areas covered under FCC 47 CFR Part 15 a minimum separation
of 23 cm (8 inch) between antenna and the human body must be maintained.
•
The operation manual should be conveniently kept available at all times for each user.
•
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
unauthorized measures shall exclude any liability by the manufacturer.
•
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors,
or omissions in the manual or automatically set parameters for a device or for an incorrect
application of a device.
•
Repairs may only be executed by the manufacturer.
•
Installation, operation, and maintenance procedures should only be carried out by qualified
personnel.
•
Use of the device and its installation must be in accordance with national legal requirements
and local electrical codes .
•
When working on devices the valid safety regulations must be observed.
•
Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep
a minimum distance of 25 cm between the device and your cardiac pacemaker.
FEIG ELECTRONIC GmbH
Page 22 of 36
M91002-0de-ID-B.doc
ENGLISH
6. Safety Instructions / Warning - Read before start-up !
OBID®
Installation
ID ISC.MU02.02
7. Performance Characteristics of the ID ISC.MU02.02 Reader Module
The ID ISC.MU02.02 Reader Module is designed for reading and writing passive transponders, socalled “Smart Labels”, with an operating frequency of 860 – 960 MHz. It is suitable for any application in which short and middle read ranges and small reader dimensions are required.
The module has 2 integrated antenna outputs for connecting 2 different 50 Ω antennas.
7.2. Available module types
The following module types are currently available:
Module type
Description
ID ISC.MU02.02-AD
Reader Module with RS232 and data/clock interface, external supply
voltage of 5 V DC
ID ISC.MU02.02-CU
Reader Module with RS232-LVTTL and USB interface, external supply
voltage of 5 V DC or directly over USB
7.3. Optional available
The following components are optional available. This parts are necessary if the reader ID
ISC.MU02.02 should be connect to a PC COM-Port.
Accessories
Order number
ID CAB.A-A Cable for Adaption of RS232 and Data/Clock
2259.000.00.00
ID CAB.RS-A Cable for RS232 and Power supply
1690.000.00.00
RS232-TTL Converter
1962.000.00.00
ID Net.5V Power Supply
1689.000.00.01
ID CAB.USB-B Cable for USB
3541.000.00.00
ID ISC.ANT.C05-A UHF antenna cable U.FL-U.FL 500 mm
3540.000.00.00
ID ISC.ANT.U75/50-EU UHF antenna module 865 – 868 MHz
3544.000.00.00
ID ISC.ANT.U75/50-FCC UHF antenna module 902 – 928 MHz
3543.000.00.00
FEIG ELECTRONIC GmbH
Page 23 of 36
M91002-0de-ID-B.doc
ENGLISH
7.1. Performance Characteristics
OBID®
Installation
ID ISC.MU02.02
8. Installation and wiring
8.1. Dimensions
ENGLISH
Fig. 1 shows the dimensions of the ID ISC.MU02.02 Reader Module in mm.
44
50
50
44
3,
Ø
13,4
11,4
Fig. 1: Dimensions of the ID ISC.MU02.02 Reader Module in mm
FEIG ELECTRONIC GmbH
Page 24 of 36
M91002-0de-ID-B.doc
OBID®
Installation
ID ISC.MU02.02
8.2. Wiring
10
Fig. 2: Pin assignments for Terminal X2
**
Pin
Function
Description
DAT
Data line for the data/clock interface
CLK
Clock line for the data/clock interface
TxD
RS232-TTL – Transmit Data
GND **
Ground
RxD
RS232-TTL – Receive Data
SHDN
Shut Down
CLS
CLS line for the data/clock interface
VCC *
+ 5 V DC
GND **
Ground
10
---
no function (use ONLY open!)
Use only regulated DC power supplies !
GND-Pins 4 and 9 are to be connected directly to each other
on the Reader Module
Table 1: Pin assignments for Terminal X2
FEIG ELECTRONIC GmbH
Page 25 of 36
M91002-0de-ID-B.doc
ENGLISH
Fig. 2 and Table 1 show the pin assignments for Terminal X2. The pin connector is designed for
flat cable connection using an IDC multipoint socket connector with 2.54 mm pin spacing.
OBID®
Installation
ID ISC.MU02.02
8.2.1. Supply voltage
The ID ISC.MU02.02 must be supplied only by a regulated power supply.
If switching power supplies are used with the module, be sure that there is adequate filtering.
The cable length from the power supply should be as short as possible, and should in any case not
exceed 3 m.
X2
Pin no.
Function
Description
VCC *
+ 5 V DC ± 5%
4, 9
GND **
Ground
**
Use only regulated power supplies !
GND-Pins 4 and 9 are to be connected directly to each
other on the Reader Module
Table 2: Pin assignments for X2
NOTE:
• Reversing the polarity of the supply voltage may destroy the device.
• Supply voltages outside the specifications may destroy the device.
FEIG ELECTRONIC GmbH
Page 26 of 36
M91002-0de-ID-B.doc
ENGLISH
Noise from the power supply can result in a reduction of the read/write range of the module.
OBID®
Installation
ID ISC.MU02.02
8.2.2. RS232 interface
The length of the cable to the RS232 interface should be kept as short as possible, and must in
any case not exceed 3 m.
Function
4, 9
**
Description
TxD *
RS232 - Transmit Data
GND **
Ground
RxD *
RS232 - Receive Data
ENGLISH
X2
Pin no.
Signal names as seen by the Reader Module.
GND-Pins 4 and 9 are to be connected directly to each
other on the Reader Module
Table 3: Pin assignments for the RS232 interface on X2
The transmission parameters for the interface can be software-configured. Table 4 shows the
standard parameters for the RS232 interface.
Parameter
Standard setting
Baud rate
38400
No. of data bits
Parity
Even
No. of stop bits
Table 4: Standard parameters of the RS232 interface.
Note:
•
If there is an USB/RS232 converter used on the PC/Notebook side, we recommend to
increase the „Char Timeout Multiplier“ parameter in the COM-Port settings from „1“ to
about „10“.
•
IF there is a RS232 to TTL converter used without external power supply it may be necessary to switch on the COM Port parameter “RTS” and “DTR” manually.
FEIG ELECTRONIC GmbH
Page 27 of 36
M91002-0de-ID-B.doc
OBID®
Installation
ID ISC.MU02.02
8.2.3. Data/Clock interface
The length of the cable to the data/clock interface should be kept as short as possible. It must not
exceed 3 m.
X2
Pin no.
Function
DAT
Data line for the data/clock interface
CLK
Clock line for the data/clock
interface
CLS
CLS line for the data/clock interface
4, 9
GND *
Ground
ENGLISH
Description
GND-Pins 4 and 9 are to be connected directly to each
other on the Reader Module
Table 5: Pin configuration for the RS232 interface on Terminal X2
Host
Data
Clock
CLS
GND
DAT
CLK
CLS
GND
ID ISC.MU02
Fig. 3: Connecting the data/clock interface
FEIG ELECTRONIC GmbH
Page 28 of 36
M91002-0de-ID-B.doc
OBID®
Installation
ID ISC.MU02.02
8.2.4. Shut Down
X2
Pin no. 6
Operating status
not connected
on
Ground (GND)
off
ENGLISH
The ID ISC.MU02.02 can be switched off with the SHDN pin (pin no. 6 at terminal X2). Therefor the
pin has to be connected to Ground.
Table 9: Status table for the SHDN pin
Note:
• Supply voltages outside the specifications may destroy the device.
8.3. USB interface
Fig. 4 and Table 7 show the pin assignments for Terminal X1 (“JST PH” type with pitch 2.0 mm).
Fig. 7: Pin assignments for Terminal X1
FEIG ELECTRONIC GmbH
Page 29 of 36
M91002-0de-ID-B.doc
Installation
ID ISC.MU02.02
Pin
Function
Description
SHIELD
Shielding
GND
Ground
D+
USB-D PLUS
D–
USB-D MINUS
VCC
5 V power supply
ENGLISH
OBID®
Table 10: Pin assignments for Terminal X1
The power supply follows though the USB-interface (Bus powered).
The USB interface must support a current of 500mA (High Powered Interface).
The data rate of the reader is reduced to 12 Mbit (USB high speed).
If the reader is used for the first time, it must be registered in the operating system of the computer.
For this the instruction "M70700-xde-ID-B: Installation OBID® USB driver" can be used.
Note:
• If the ID ISC.MU02.02 is USB powered there MUST NOT connected a power supply to
terminal X2.
8.4. Antenna ports
There can be 2 antennas connected to the ID ISC.MU02.02 at the antenna ports ANT1 and ANT2.
Fig. 5 shows the position of the “Hirose U.FL” receptacles with an input impedance of 50 Ω. The
antennas can be switched by software.
Fig. 5: Antenna ports ANT1 and ANT2
FEIG ELECTRONIC GmbH
Page 30 of 36
M91002-0de-ID-B.doc
OBID®
Installation
ID ISC.MU02.02
8.5. Display elements
ENGLISH
The ID ISC.MU02.02 Reader Module has a red LED (V1) and a green LED (V2) and a blue LED
(V3) which are used as display elements (Fig. 6).
Fig. 6: Position of the LEDs
The functions of both LEDs V2 and V3 can be configured using software protocol. It is also possible to control all 3 LEDs directly using an additional software protocol.
FEIG ELECTRONIC GmbH
Page 31 of 36
M91002-0de-ID-B.doc
OBID®
Installation
ID ISC.MU02.02
Table 8 shows the standard setting for the LEDs.
V1
Color
Red
Standard setting
• Flashes 5x after a reset.
• Off during normal operation.
• Flashing alternately with V2 during failure
status.
• Flashes 5x after a reset.
• On during normal operation.
V2
Green
• Off for 1 second after successful communication with a transponder.
• Flashing alternately with V1 during failure
status.
• Flashes 10x after a reset.
V3
Blue
• Comes on for 1 second after successful
communication with a transponder.
Table 8: Standard setting for the LEDs
8.6. Installation notes
Be aware of the following possible environmental factors when installing an ID ISC.MU02.02 into
another device :
•
Effects from nearby metal objects
⇒ Detuning of the integrated antenna
⇒ Impaired propagation of the antenna’s electromagnetic field
•
EMC effects on cables
⇒ Impaired communication between reader and transponder
8.6.1. Metallic surroundings
When installing an ID ISC.MU02.02 into another device, be sure that there are no metal surfaces
or objects in the direct vicinity of the connected antennas if possible. These can detune the antenna and impair the propagation of the electromagnetic field due to reflections. This will in turn
result in reading holes and overshoots.
The distance between the antennas and a metal surface should be at least 5 cm. Note that
even other circuit boards may act line metal objects depending on how much copper they
contain.
FEIG ELECTRONIC GmbH
Page 32 of 36
M91002-0de-ID-B.doc
ENGLISH
LED
OBID®
Installation
ID ISC.MU02.02
If a metallic surrounding cannot be avoided, stable function should at least be ensured by keeping
the distance as great as possible.
The area between the antenna and transponder as well as the area on the other side of the transponder should also be kept clear of metal parts.
In spite of the internal EMC filters inside the reader, high levels of noise on the supply voltage can
result in impairment of the communication between the reader and transponder.
When installing an ID ISC.MU02.02 into another device, be sure therefore that a clean, noise-free
power supply is used.
9. Radio Approvals
9.1. Europe (CE)
When used according to regulation, this radio equipment conforms with the basic requirements of
Article 3 and the other relevant provisions of the R&TTE Guideline 1999/5/E6 dated March 99.
Equipment Classification gemäß ETSI EN 301 489: Class 2
FEIG ELECTRONIC GmbH
Page 33 of 36
M91002-0de-ID-B.doc
ENGLISH
8.6.2. EMC effects on cables
OBID®
Installation
ID ISC.MU02.02
9.2. USA (FCC)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
NOTICE:
Changes or modifications made to this equipment not expressly approved by
FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
This device is labeled with an FCC ID number.
If this label is not visible when installed in an end device, the outside of the device MUST
also display a label referring to the enclosed module.
Wording on the label similar to the following shall be used:
This device contains transmitter module FCC ID PJMMU02
At the time of this printing, the antennas listed below were the only antennas approved for
use with the ID ISC.MU02.02 module. Use of other antennas must be approved by
FEIG ELECTRONIC GmbH.
Antennas approved:
ID ISC.ANT.U170/170-FCC
ID ISC.ANT.U100/75-FCC
ID ISC.ANT.U75/50-FCC
FEIG ELECTRONIC GmbH
Page 34 of 36
M91002-0de-ID-B.doc
ENGLISH
FCC ID: PJMMU02
OBID®
Installation
ID ISC.MU02.02
10. Technical Data
Mechanical Data
50 mm x 50 mm x 14 mm
(1,97 inch x 1,97 inch x 0,55 inch)
• Weight
10 g (0,02 lb)
• Connector
•
10-pin connector, spacing 2.54 mm (0,1 inch)
•
5-pin connector,
type “JST PH” pitch 2 mm (0,079 inch)
Electrical Data
• Supply voltage
5 V DC ± 5%
• Power consumption
max. 2 W
• Operating frequency
860 ... 960 MHz
• Transmitting power
max. 170 mW ; reducible
• Antenna connection
2 x “Hirose U.FL” receptacles; 50 Ω; switchable
• Interfaces
Variant AD
RS232-V24, Data/Clock
Variant CU
RS232-LVTTL, USB
FEIG ELECTRONIC GmbH
Page 35 of 36
M91002-0de-ID-B.doc
ENGLISH
• Dimensions (W x H x D)
OBID®
Installation
ID ISC.MU02.02
• Protocol Modes
- FEIG ISO HOST
- Scan Mode
• Supported transponders
EPC Class 1 Gen 2
• Visual indicators
3 LED (red / green / blue)
Ambient Conditions
• Temperature range
- Operation
- Storage
• Humidity
-25°C to +55°C
-25°C to +85°C
(-13°F to 131°F)
(-13°F to 185°F)
5 – 95% non condensing
Applicable Norms
• Radio approval
- Europe
- USA
EN 302 208
FCC 47 CFR Part 15
• EMC
EN 301 489
• Safety
EN 60950
FEIG ELECTRONIC GmbH
Page 36 of 36
M91002-0de-ID-B.doc
ENGLISH
Functional Properties

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 36
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:89278374-81e9-4625-a6bd-e873def70470
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Company                         : FEIG ELECTRONIC GmbH
Create Date                     : 2010:02:12 12:50:50+01:00
Creator Tool                    : Acrobat PDFMaker 6.0 für Word
Modify Date                     : 2010:02:12 12:51:14+01:00
Metadata Date                   : 2010:02:12 12:51:14+01:00
Document ID                     : uuid:b50aa828-c43c-43ae-8666-e259d4d8be64
Format                          : application/pdf
Title                           : 
Creator                         : Michael Rödig
Author                          : Michael Rödig
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PJMMU02

Navigation menu