Feig Electronic PRH101 Inductive Tag Reader User Manual Installation ID ISC PRH101

Feig Electronic GmbH Inductive Tag Reader Installation ID ISC PRH101

Users Manual

INSTALLATIONfinalpublic (B)2005-11-01M50800-0e-ID-B.docOBID i-scan®ID ISC.PRH101-AID ISC.PRH101-BID ISC.PRH101-USB
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 2 of 18 M50800-0e-ID-B.docNote Copyright 2005 byFEIG ELECTRONIC GmbHLange Strasse 4D-35781 Weilburg-WaldhausenTel.: +49 6471 3109-0http://www.feig.deWith the edition of this document, all previous editions become void. Indications made in this manual may bechanged without previous notice.Copying of this document, and giving it to others and the use or communication of the contents thereof areforbidden without express authority. Offenders are liable to the payment of damages. All rights are reservedin the event of the grant of a patent or the registration of a utility model or design.Composition of the information in this document has been done to the best of our knowledge. FEIGELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in thismanual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONICGmbH does not give any guarantee promise for perfect function in cross environments.FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in thisdocument and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbHdoes not convey any license under its patent rights nor the rights of others.OBID® and OBID i-scan® are registered trademarks of FEIG ELECTRONIC GmbH.I-CODE® is a registered trademark of Philips Electronics N.V.Bluetooth® is a registered trademark of Bluetooth SIG Inc.
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 3 of 18 M50800-0e-ID-B.docContents1.  Safety Instructions / Warning - Read before start-up ! 42.  Performance Features of the ID ISC.PRH101 52.1.  Performance features .........................................................................................................52.2.  Available Reader-Types......................................................................................................53.  Control and Display Elements 63.1.  Signal buzzer .......................................................................................................................63.2.  Scan - button .......................................................................................................................63.3.  LED .......................................................................................................................................74.  Assembly and Wiring 84.1.  Reader with asynchronous interface ID ISC.PRH101-A ..................................................84.1.1.  Asynchronous interface RS232 .....................................................................................84.1.2.  Supply voltage ...............................................................................................................94.2.  Reader with Bluetooth™ interface ID ISC.PRH101-B.....................................................104.2.1.  Bluetooth™(BT) interface ............................................................................................104.2.2.  Supply voltage .............................................................................................................114.2.3.  Charging the batteries .................................................................................................124.2.4.  Reset - button (ID ISC.PRH101-B only) ......................................................................134.3.  Reader with USB-interface ID ISC.PRH101-U .................................................................135.  Technical Data 146.  Approvals 166.1.  USA  (FCC) .........................................................................................................................166.2.  Europe  (CE).......................................................................................................................167.  Appendix 187.1.  Accessories .......................................................................................................................187.2.  Scope of delivery...............................................................................................................18
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 4 of 18 M50800-0e-ID-B.doc1. Safety Instructions / Warning - Read before start-up !• The device may only be used for the intended purpose designed by for the manufacturer.• The operation manual should be conveniently kept available at all times for each user.• Unauthorized changes and the use of spare parts and additional devices which have not beensold or recommended by the manufacturer may cause fire, electric shocks or injuries. Suchunauthorized measures shall  exclude any liability by the manufacturer.• The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are validfor the device. The manufacturer shall  not be held legally responsible for inaccuracies, errors,or omissions in the manual or automatically set parameters for a device or  for an incorrectapplication of a device.• Repairs may only be executed by the manufacturer.• Installation, operation, and maintenance procedures should only be carried out by qualifiedpersonnel.• Use of the device and its installation must be in accordance with national legal requirementsand local electrical codes .• When working on devices the valid safety regulations must be observed.• Special advice for carriers of cardiac pacemakers:Although this device doesn't exceed the valid limits for electromagnetic fields you should keepa minimum distance of 25 cm between the device and your cardiac pacemaker.
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 5 of 18 M50800-0e-ID-B.doc2. Performance Features of the ID ISC.PRH1012.1. Performance featuresThe ID ISC.PRH101 are devices for contactless data exchange with common Transponder ac-cording ISO 15693. The readers have an internal antenna and will be delivered ready for connec-tion. The device is designed as a handheld.An anti-collision function enables simultaneous reading of several transponders per second.The Reader electronic is fitted in a plastic housing with a protection class IP30.The Reader ID ISC.PRH101-A has an asynchronous RS232 interface, the ID ISC.PRH101-B hasan Bluetooth interface and the ID ISC.PRH101-USB has an USB interface. 2.2. Available Reader-TypesFollowing Reader-Types are available at present:Reader-Types DescriptionID ISC.PRH101-A asynchronous RS232 interface with internal antenna andvoltage supply by means of external 5 VDC power supply.ID ISC.PRH101-B Bluetooth interface with internal antenna andvoltage supply by means of 4 rechargeable Mignon AA batteriesID ISC.PRH100-USB USB interface with internal antenna andvoltage supply by means of USB-High Powered InterfaceTabelle 1: Reader-Types
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 6 of 18 M50800-0e-ID-B.doc3. Control and Display ElementsLEDScan-buttonFig. 1: Control and Display Elements3.1. Signal buzzerThe signal buzzer can be configured by the software.In the standard configuration the signal buzzer will be active if a Transponder is recognised.3.2. Scan - buttonThe switch of the reader can be configured by the software. In the standard configuration the serial number of the Transponder is read and is sent to the hostafter pressing the scan - button.
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 7 of 18 M50800-0e-ID-B.doc3.3. LEDThe Reader’s LED can be configured through software.Abbreviation DescriptionLED green "RUN "- Turns on when the Reader is ready.- Flashes during Bluetooth initialization.(only ID ISC.PRH101-B)LED blue „TRANSPONDER“- Turns on when a Transponder is detected.LED red „WARNING“- Signals a warning- flashes if battery voltage is too low(rechargeable battery  must be charged –only ID ISC.PRH101-B)- Turns on if battery voltage is flat(no more scanning possible - only ID ISC.PRH101-B)LED orange „INITIALIZING “-  Flashes during Reader initialization after power-up.Table 2: Standard configuration of the LEDs
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 8 of 18 M50800-0e-ID-B.doc4. Assembly and Wiring4.1. Reader with asynchronous interface ID ISC.PRH101-A4.1.1. Asynchronous interface RS232D-Sub 9pol. female2 - RxD3 - TxD 5 - GNDDC Jack2,5 x 5,5mmGND(outside)5V DC(inside)Fig. 2: Connection plug of the readersThe reader has a fixed connected interface cable with a connection for the power supply. The con-nection of the RS232 interface follows over the 9-pin D-Sub socked. The COM-port settings can be configured by the softwarePin configuration of the 9-pin D-Sub socked (RS232-Interface):Pin Symbol Description2TxD RS232 – TxD3RxD RS232 – RxD5GND RS232 – GND1; 4; 6-9 --- n.c.Tabelle 3: Pin configuration of the RS232 interface
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 9 of 18 M50800-0e-ID-B.doc4.1.2. Supply voltageVoltage supply will be connected via the DC Jack at the end of the interface cable. Connect a re-gulated 5 V DC supply voltage.The reader must be supplied with a “Limited power source”. This power-supply is allowed to supplya maximum current of 8 ampere. DC-CouplerPlug Symbol DescriptionInside +5V + 5,0 V DC ± 0,2 V – Power SupplyOutside GND Ground – Power SupplyTable 4: Connecting of the Power SupplyNote:• Reversing the polarity of the supply voltage may destroy the device.• Voltages of more than 5.5 VDC may destroy the devicePower supply recommendations : To take full advantage of the Reader module performance, you must use a sufficiently regulatedand low-noise power supply. Preferred is a linear power supply with 5V DC / 1300 mA. When usinga switching power supply, be sure that its internal switching frequency is less than 300 kHz.(see:7.1. Accessories).Feig Article No. Part No.1689.000.00.00 ID NET.5VDCTable 5: Recommended power supply
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 10 of 18 M50800-0e-ID-B.doc4.2. Reader with Bluetooth™ interface ID ISC.PRH101-BThe Reader has a Bluetooth port. The supply voltage is provided only by rechargeable batteries.The Reader is activated using the Scan button. This opens a Bluetooth connection automaticallywithin approx. 3 seconds. The Reader is now ready to use. After releasing the button, the Readerremains active for several minutes. During this time the Bluetooth connection remains open.Pressing the button again immediately starts a Scan.4.2.1. Bluetooth™(BT) interfaceCommunication to the Reader is through a Bluetooth connection. Bluetooth is a short-distancewireless RF connection which enables permanent wireless communications connections betweenportable and desktop or peripheral devices. Each Bluetooth device has a unique address and canbe optionally identified with a self-explanatory name. Password protection is used for security of aBluetooth connection, with the Bluetooth partner being added to a confidential list. SSP (Serial PortProfile) is used.Initial setup of a „paired connection“ to the Reader is done by the host. After initial setup thishappens automatically by pressing the button.All Readers have a factory set name and a preset password. The name "OBID_PRH101B"consists of a fixed (OBID_PRH) and a user modifiable (101B) part.Description Default settingName variable 101BPassword 1234Table 6: Standard configuration of the Bluetooth Interface
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 11 of 18 M50800-0e-ID-B.doc4.2.2. Supply voltageThe Reader is powerd by rechargeable batteries. Four AA type rechargeable batteries are used.These are inserted into the handle of the Reader. To change the batteries, remove the batterycover. After unlatching the springs the cover can be removed. The rechargeable batteries areplaced in the compartment according to the + and – symbols indicated (note polarity). Thenreplace the cover and listen for the spring to audibly latch. General type Europe USA Size (D*l)Mignon R6 / UM-3 AA 15mm * 51mmTable 7: Designations for rechargeable Mignon-type batteriesNotes:• Use only Nickel/Cadmium (NiCd) or Nickel/Metal Hydride (NiMH) batteries.• Do not use single-use batteries (e.g. zinc-carbon / alkaline) batteries.• Reversed polarity may destroy the device.• Rechargeable batteries should never be discarded with normal trash; please return themto a proper collection location !Fig. 3: Inserting the rechargeable batteries
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 12 of 18 M50800-0e-ID-B.doc4.2.3. Charging the batteriesDC-PlugReset - buttonMinus (outside)Plus (inside)Fig. 4+ 5: ID ISC.PRH101-B: Reset button and DC plug 2.1mm*5.5mmThe rechargeable batteries may remain in the Reader for charging. You will need an externalcharger connected to the DC jack.DC jack Abbreviation DescriptionInside +Plus – charge voltageOutside -Minus – charge voltageTable 8: Charger connectionNote:• Reversing the polarity of the charger can destroy the batteries.• The Reader is not functional while the batteries are charging.
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 13 of 18 M50800-0e-ID-B.docCharger : Use a charger suitable for the battery type specified (4-cell pack). Feig Article No. Name2650.000.00 ID CHA.NiMH-ATable 9: Recommended chargerThe recommended charger is designed for nickel/cadmium (NiCd) type rechargeable batteries andnickel/metal hydride (NiMH) with a capacity range of 800mAh to 7200 mAh.Alternately the batteries can be removed from the Reader and charged in a separate batterycharger.4.2.4. Reset - button (ID ISC.PRH101-B only)The Reader has a reset button. This restores the Bluetooth settings to their original configuration.Below the yellow Scan button is a small hole in the housing. Below this is the Reset button. Afteractivating the Reader with the Scan button the Reader is reset to its factory settings by holding theReset button down for longer than 3 seconds.4.3. Reader with USB-interface ID ISC.PRH101-UThe Powersupply follows though the USB-interface (Bus-powered)The USB-interface must support a current of 500mA (High Powered Interface)The data rate of the reader is reduced to 12 Mbit (USB high speed).The reader dispose of a fixed connected interfaces cable with standardized USB-connector. TheReader must only be connected to the USB-port of the PC. If the reader is used for the first time, it must be registered in the operating system of the computer.For this the instruction "M30100-xde-ID-B: Installation of the OBID USB driver" can be used
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 14 of 18 M50800-0e-ID-B.doc5. Technical DataMechanical Data• Housing ABS plastic (enclosed)• Dimensions ( W x H x D ) 230 x 100 x 80 mm• Weight 320 g• Degree of Protection IP 30• Cable length– ID ISC.PRH101-A– ID ISC.PRH101-B– ID ISC.PRH101-USBapprox. 8,2´/2,5 mno cableapprox. 8,2´/2,5 m• Color similar RAL 9002Electrical Data• Supply voltage– ID ISC.PRH100-A– ID ISC.PRH101-B– ID ISC.PRH100-USB5,0 V DC ± 0,2 V regulated4 Mignon AA recharchable batteriesUSB - High Powered Interface• Power consumption max. 2,5 VA• Operating frequency 13,56 MHz• Transmitting Power 0,5 W ± 2 dB• Antenna internal antenna• Interface– ID ISC.PRH100-A– ID ISC.PRH101-B– ID ISC.PRH100-USBRS232Bluetooth (Serial port profile)USB (12 Mbit)
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 15 of 18 M50800-0e-ID-B.docFunctional Properties• Supported Transponders - ISO 15693 compatible- I•Code 1- optional I•Code EPC und I•Code UID• Address setting for interface– ID ISC.PRH101-B– ID ISC.PRH100-USBBluetooth MAC addressDevice ID of the Readers• Indicators– optical– acoustical1 LED ( multicolor – red / green / blue)buzzerAmbient Conditions• Temperature range– Operation– Storage   0°C to +50°C-20°C to +70°C• Humidity 5 – 95% non condensingApplicable Norms• Radio approval– Europe– USAEN 300 330FCC 47 CFR Part 15• EMC ETSI EN 301 489• Safety- low voltage- Human ExposureEN 60950EN 50364• Fall Withstands multiple 5´/1,5 m drops to concrete
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 16 of 18 M50800-0e-ID-B.doc6. Approvals6.1. USA  (FCC)FCC ID  PJMPRH101This device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that maycause undesired operation.Any changes or modifications not expressly approved by the party responsible forcompliance could void the user´s authority to operate the equipment.6.2. Europe  (CE)When properly used this radio equipment conforms to the essential requirements of Article 3 andthe other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 17 of 18 M50800-0e-ID-B.doc
OBID i-scan ® Installation ID ISC.PRH101FEIG ELECTRONIC GmbH Page 18 of 18 M50800-0e-ID-B.doc7. Appendix7.1. AccessoriesThe following accessories are available for the Reader.Artikel Nr. Bezeichnung Beschreibung1689.000.00 ID NET.5VDC 5 V DC power supply with suitable con-nector for ID ISC.PRH101-A.2650.000.00 ID CHA.NiMH-A Batterie charger with suitable connectorfor ID ISC.PRH101-BTable 10: Accessories7.2. Scope of deliveryReader Scope of deliveryID ISC.PRH101-A- Reader ID ISC.PRH101-A- Quick user guide- CDID ISC.PRH101-B- Reader ID ISC.PRH101-B- Quick user guide- CD incl. driverID ISC.PRH101-USB- Reader ID ISC.PRH101-USB- Quick user guide- CD  Table 11: Scope of deliveryNote:Power supply, rechargeable batteries and battery charger are not included in delivery