Fiber Span FS31X-4 FIBER OPTIC SYSTEM/ REPEATER User Manual Fiber Span FS31 Series Manual
Fiber-Span LLC FIBER OPTIC SYSTEM/ REPEATER Fiber Span FS31 Series Manual
users manual
Fiber-Span Fiber Optic RF Repeater System FS31 Series User Manual Page 1 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System Fiber-Span ..........................................................................................................................1 Fiber Optic RF Repeater System ......................................................................................1 FS31 Series User Manual ....................................................................................................1 1 Introduction ...................................................................................................................2 2 Warnings.......................................................................................................................2 Warning: Invisible radiation exits from areas labeled “Aperture” .........................................2 3 Product Overview..........................................................................................................3 4 Product Diagrams .........................................................................................................4 5 RF Path Definitions .......................................................................................................6 6 Installation Guide ..........................................................................................................6 6.1 General ..................................................................................................................6 6.2 Fiber Transceiver Unit (FTU) .................................................................................6 6.3 Remote Repeater Unit (RRU) and Integrated Head-end Unit (IHU) ......................7 6.4 Caution ................................................................................................................12 7 Maintenance ...............................................................................................................12 8 Company Information..................................................................................................12 9 Reference Documents ................................................................................................13 Introduction This manual outlines the operation and setup for Fiber-Span Fiber Optic Based RF Repeaters. Warnings Figure 1. Laser Warning Label Warning: Invisible radiation exits from areas labeled “Aperture” AC power is used to supply power up the system modules. Use precautions to prevent electrical shock hazards. Always terminate the RF connections before applying power to the unit. Page 2 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System 3 Product Overview Fiber-Span provides product to enable RF signal to be distributed via optical fiber cable. RF signal sources can be used from over the air (OTA) from a Radio Base Station (BS), OTA from handheld devices, or directly from a BS radio. RF signals are converted to modulated light for transport through optical fiber media to remote locations. Modulated light is converted back to the original RF signal where it is processed through filtering and amplification to allow the RF signal to be re-radiated in the remote location. In a bi-directional RF system, the process is the same resulting in remote RF signals that are sent back simultaneously. Fiber-Span product functionality OTA system - RF signals from a remote base station are interchanged usually from a roof top antenna that is connected to an Integrated Head-end Unit (IHU). The IHU receives downlink signals from the base station and sends uplink signals back to the base station. The IHU distributes signals via fiber optics to remote location and also is capable of simultaneously interfacing with a Distributed Antenna System (DAS) for short range RF distribution. IHU DAS in Building RRU Optical Fiber DAS in Building Remote Base Station Figure 2. Typical OTA Optical RF distribution System Local Base Station System – Signals from a local base station interface to optical distribution equipment through Base Station Units (BSU), or directly to a Fiber Transceiver Unit (FTU). The BSU sometimes interfaces the Base Station to the FTU. The BSU is used to passively condition RF levels or serve as RF filters when applicable. The FTU performs bi-directional optical-RF conversions. Optical signals are sent to the Remote Repeater Unit (RRU). The RRU is designed for use as a remote end of a bi-directional RF distribution system. The RRU RF port works with a direct connected RF antenna or to a Distributed Antenna System (DAS). The RRU is connected via optical fibers to a Fiber Transceiver Unit (FTU) to complete a point to point RF link. Page 3 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System RRU RRU RRU RRU Optical Fiber BTS BSU FTU Figure 3. Local Base Station System Product Diagrams RRU Block Diagram Door Switch FC/APC [Opt Out] FC/APC [Opt In] PA LN N-F [RF] LN Fiber Transceiver PA [Alarm] Control Board Power Supply +28V Power Supply +12V Line Cord Figure 4. Simplified Block Diagram of RRU Page 4 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System [Laser Alarm] [Receiver 1 Alarm] [Receiver 2 Alarm] [Power] [Receiver 3 Alarm] [Receiver 4 Alarm] FTU Block Diagram Optical 4-Way 4-Way RF Combiner Fiber Optic Receiver Fiber Optic Receiver Fiber Optic Receiver Power Supply Fiber Optic Transceiver [RF Out] N-RF Optical Out (4) FC/APC [Summary Alarms] Optional [Opt Out 4] [Opt Out 3] [Opt Out 2] [Opt Out 1] [Gain 1] [Opt In Alm 1] [Gain 2] [Opt In Alm 2] [Gain 3] [Opt In Alm 3] [Gain 4] [Opt In Alm 4] [Laser Alm 1] Optical In (4) FC/APC [Opt In 4] [Opt In 3] [Opt In 2] N-RF [Opt In 1] B CPl ort no C [RF In] AC Power Entry Figure 5. FTU Block Diagram (4-Way FTU Shown) Page 5 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System 5 RF Path Definitions The RF paths are defined as follows: Downlink – Originates at the FTU or and IHU, over fiber to the RRU to the RF Port. The Downlink generally is defined by the RF output power the RRU can deliver. Uplink – Originates at the RRU, over the fiber to the FTU or IHU to the RF Out Port. The Uplink is generally defined by RF input sensitivity. 6.1 Installation Guide General All unused RF Terminals must be terminated with a 50 Ohm load. All unused Optical Terminals must be protected using dust cover cap. When installing fiber optic cables, remove dust covers, clean optical connector with optical grade alcohol, align FC/APC connector KEY and hand tighten. Do not over tighten. Keep fiber bend radiuses greater than 1.5 inches. 6.2 Fiber Transceiver Unit (FTU) The Fiber Transceiver Unit (FTU) is a 19” standard 1U sub-rack. The FTU requires AC Power (90 to 220 VAC, 50-60 Hz). The AC interface is a standard IEC Power socket. A US 120V AC Line Cord is supplied with each FTU. Mount Fiber Transceiver Unit away from excessive heat sources. Make all RF connections and terminate all unused RF connections before applying AC Power. User interface information can be found in attached outline drawing. Figure 6. FTU Front View Figure 7. FTU Rear View Page 6 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System Alarms The Opt in Alarm interface uses a wire contact header (supplied) that will plug into the Opt in Alarm sockets. Connection of alarm wires to the wire contact header requires a small standard flathead screwdriver. The connections are dry contact relay terminals. The alarm LED’s on the front panel indicate alarm conditions for each individual uplink optical receiver and downlink optical transmitter. An optional Summary alarm is available. A receiver alarm is triggered by excessive optical loss. The transmitter alarm is triggered when the laser transmitter runs over bias. Normal operation leaves the contacts normally open (NO). In the event of an alarm condition, the corresponding contacts close. RF Levels For the uplink, each receiver has a gain control that is accessed using a small standard screwdriver on the FTU rear. For Uplink, disconnect the downlink optical fiber on the FTU side to ensure that there is no RF output at the RRU RF port. Turn down the gain on ALL FTU receivers (if FTU is more than a 1-Way) using gain control by turning CCW at least 12 turns. On the RRU side, connect a RF tone generator set to an RF level of -50 dBm at the center of the uplink frequency. On the FTU, set RF output to the desired level at the FTU RF output by adjusting corresponding FTU receiver gain control. Repeat for other Uplinks individually if applicable and leave gain settings of previous calibrated uplinks unchanged. The goal is to balance the uplink gains to be all equal. For downlink, provide composite RF level into FTU transceiver at 0 dBm. All unused RF Terminals must be terminated with a 50 Ohm load. All unused Optical Terminals must be protected using dust cover cap. When installing fiber optic cables, remove dust covers, clean optical connector with optical grade alcohol, align FC/APC connector KEY and hand tighten. Do not over tighten. Keep fiber bend radiuses greater than 1.5 inches. 6.3 Remote Repeater Unit (RRU) and Integrated Head-end Unit (IHU) The RRU/IHU requires AC Power (90 to 220 VAC, 50-60 Hz). Connect RRU to earth ground using Earth Ground Lug on the external side of RRU. If the unit is a wall mount type, use the dimensional information provided with the Outline Drawing (example attached). Mount on a sturdy location keeping clear vent holes and heatsink. If the unit is a rack mount type, mount the unit to allow air passage from front to back. Space the units to allow convection air flow. If the unit is mounted inside a larger enclosure, air ventilation must be used to keep the RRU in proper temperature Page 7 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System range. Make all RF connections and terminate all unused RF connections before applying AC Power. Figure 8. RRU/IHU (Wall Mount Version) Bottom Side Figure 9. RRU/IHU (Rack Mount Version) Alarms The alarm interface uses a circular connector. The connections are dry contact relay terminals. The alarm LED’s on the Control Board indicate the alarm conditions for each individual parameter as: Downlink Optical Receiver Uplink Optical Transmitter PA Alarm Door Alarm (Wall Mount) / Fan Alarm (Rack Mount) Page 8 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System See LED alarm indicator locations in Figure 10. A receiver alarm is triggered by excessive optical loss. The transmitter alarm is triggered when the laser transmitter runs over bias. The PA alarm indicates that the PA is overdriven. The Door / Fan alarm indicates when the door is left open or if a cooling fan fails. The alarm output is summarized which makes one set of contacts available on the circular alarm connector. Normal operation leaves the contacts normally open (NO). In the event of an alarm condition, the corresponding contacts close. RF Levels The Downlink Output level is factory set to meet the RF maximum output level that is compatible with FCC requirements. The uplink Gain level is factory set to optimize noise levels for the optical system. RF output levels and gain levels are adjustable using in-line RF pads. The important In-Line Pad Locations are: Door Switch FC/APC [Opt Out] FC/APC [Opt In] PA LN LN N-F [RF] Fiber Transceiver PA [Alarm] Control Board Power Supply +28V Power Supply +12V Line Cord Figure 10. RF pad locations for RRU Pad location A – Used to lower Downlink RF power without affecting the uplink parameters B – Used to lower Uplink RF level into the optical transmitter without affecting Downlink parameters C – Used to lower Uplink and Downlink levels simultaneously Parameter to be controlled Lower Downlink RF Output Power Lower Uplink RF into Optical Transceiver Page 9 of 13 Attenuator Pad A SMAFemale to SMA-Male Pad B SMAFemale to SMA-Male Comments Power Handling Wattage indicated in Table 2. Lowers Uplink Sensitivity, Maximum Composite RF input to Transceiver is 5 dBm, input P1 = 17 dBm. Rev 01 5-DEC-06 Fiber Optic RF Repeater System Lower Both Uplink and Downlink Maximum Composite RF into LNA (No Damage) +10 dBm, input P1 = -6 dBm, LNA gain is 27 dB External in-line attenuator Pad C NFemale to NMale Table 1. Attenuator Configurations IHU RF Levels The IHU downlink has a high gain to boost weak received signals to levels to drive the optical components. Do not allow a composite RF level greater than 0 dBm into the optical transceiver. See the IHU rear RF INPUT MAX information. Uplink power settings can be done as the RRU instructions. RRU RF power Considerations The RRU is available with many RF power outputs. For each product, there are considerations for pad power dissipation. Product power levels are the Output P1 dB compression point. Model Series FS31RX-A, ½ Watt FS31RX-B, 1 Watt FS31RX-C, 5 Watt FS31RX-D, 10 Watt FS31RX-E, 20 Watt Minimum Attenuator Dissipation 1 Watt 2 Watts 10 Watts 20 Watts 50 Watts Table 2. Attenuator Power Dissipation Recommendations For Attenuator A or D RRU Photographs Page 10 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System Attenuator B Attenuator A LED Alarm Indicators Figure 11. RRU Attenuator Locations Pad A and Pad B (SMA-Female to SMA-Male) Attenuator C Figure 12. RRU Attenuator Location for Pad C (N-Female to N-Male) Page 11 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System 6.3.1 Recommended System Start up Procedure 6.4 • Verify all RF cables are connected and all unused RF connections terminated with 50 Ohm terminations. • Verify all Alarm and AC connections are properly made • Connect fiber optic cables. • Apply AC power to system components. Caution RRU has internal AC power connections that can cause shock if operator is not careful. Always verify the AC Power area is clear of all objects. Do not leave objects inside the RRU that can cause dangerous shock hazard. Maintenance This Fiber Optic repeater system does not require scheduled maintenance. However, use precautions while installing optical fibers to keep connector surfaces clean. An unclean optical connector surface can damage the internal transceiver connector which can degrade system performance and violate Fiber-Span warranty. Keep heat dissipating surfaces or vents clean and clear. Company Information Fiber-Span designs and manufactures fiber optic modules and systems used in the transmission and distribution of RF and wireless signals. Fiber-Span’s fiber optic transmitters, receivers and transceivers are widely used in wireless and RF systems worldwide by wireless systems OEM’s, systems integrators and military systems designers to capitalize on the inherent advantages of fiber. Fiber has extremely low RF attenuation (< 1dB/km), very high bandwidth, immunity to EMI, no signal egress, flat broadband delay characteristics plus a cable design that is light weight and small size. Fiber-Span 111 Corporate Blvd. South Plainfield, NJ 07080 USA 908-754-0646 908-754-0647 FAX Internet http://www.fiber-span.com techinfo@fiber-span.com Page 12 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System 9 Reference Documents Example Document Title Example Document Description FS31FS-04-LM-OUT 4-Way FTU Transceiver FS31RS-90-C-06-WM-OUT RRU Transceiver, SMR-900, 5W FS31X-1.9-60-2-RM-OUT IHU Transceiver, PCS, 5W Page 13 of 13 Rev 01 5-DEC-06 Fiber Optic RF Repeater System Dwg. No. FS31FS-04-LM-OUT Rev:1 Fiber-Span 111 Corporate Blvd. S. Plainfield, NJ 07080 www.fiber-span.com FIBER-SPAN RF ON FIBER ® Technology Units: [millimeters] inches FS31FS-04-LM, Fiber Transceiver Unit, 4-Way with Local Alarms, 1U Rackmount Outline Drawing DC Power Green LED On: OK Off: Fault Optical Laser Alarm Red LED On: Fault Off: OK 457.2 18.00 Optical Receiver Alarm 1-4 Red LED On: Fault Off: OK 481.5 19.0 31.8 1.25 43.7 1.72 464.9 18.30 425.2 16.74 Optical In 1-4 FC/APC RF In N-female Received Optical Power Relays 1-4 Open: OK Closed: Low or Zero Received Optical Power Optional Alarms Optical Out 1-4 FC/APC RF Out N-female AC Power Inlet IEC 320-C14 Manual RX Gain Control Pot 1-4 Laser Alarm Relay 1 Open: OK Closed: Laser Bias Overcurrent Third Angle Projection Dwg. No. FS31RS-90-C-06-WM-OUT Rev:1 FIBER-SPAN RF ON FIBER ® Technology Fiber-Span 111 Corporate Blvd. S. Plainfield, NJ 07080 www.fiber-span.com Units: [millimeters] inches Third Angle Projection FS31RS-90-C-06-WM, Remote Repeater Unit, Wall-Mount Enclosure Outline Drawing 406.4 16.00 7.9 p. 0.31 Ty 425.5 16.75 444.5 17.50 304.8 12.00 1/4-Turn Door Latch 393 15.47 355.6 14.00 AIR VENTS - DO NOT BLOCK (Top, Bottom, & Side of Unit) Optical In FC/APC Optical Out FC/APC Note Key Location 220 8.66 Pin Locations RF port N-female Alarms Ground Stud (1/4"-20 Thread) AC Line Cord Pin Function 1 Summary Alarm 2 Summary Alarm No Connect No Connect No Connect No Connect No Connect No Connect Dry Contact Normally Open when Status is OK Dwg. No. FS31X-1.9-60-2-RM-OUT Rev:1 Fiber-Span 111 Corporate Blvd. S. Plainfield, NJ 07080 www.fiber-span.com FIBER-SPAN RF ON FIBER ® Technology Units: [millimeters] inches Third Angle Projection FS31X-1.9-60-2-RM, IHU, 1850-1990 MHz, 5W 4U Rackmount Outline Drawing Exhaust Fans Do Not Block Ground Lug 1/4"-20 Thread AC Power Entry IEC 320 Pinout Note Key Location RF N-female Optical Out 1& 2 FC/APC Alarms Remote 2 Enable Switch Optical In 1& 2 FC/APC 38.1 1.50 Air Intake Do Not Block 465.1 18.31 76.2 3.00 472.4 18.60 38.1 1.50 457.2 18.00 482 18.98 431.8 17.00 482.6 19.00 Pin Desc. Function 1 N.O. Local 2 Com. Summary Alarm 3 N.O. Remote 1 4 Com. Summary Alarm 5 N.O. Remote 2 6 Com. Summary Alarm Dry Contact Normally Open when Status is OK 176.5 6.95 101.6 4.00 DC Power Green LED On: OK Off: Fault 37.5 1.48 .406 x .250 Obround Typical Local & Remote Alarms Red LED On: Fault Off: OK
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 16 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:42e093d9-7870-4edd-8c55-8e37d56b0347 Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2006:12:07 18:09:44-05:00 Create Date : 2006:12:05 15:25:32-05:00 Metadata Date : 2006:12:07 18:09:44-05:00 Document ID : uuid:abc607c5-440d-4577-8780-da009dcb5ef4 Format : application/pdf Title : Microsoft Word - Fiber-Span FS31 Series Manual.doc Creator : jims Author : jimsEXIF Metadata provided by EXIF.tools