Fiber Span FS42R-1719-E CHANNELIZED BDA User Manual FS42R 1719E

Fiber-Span LLC CHANNELIZED BDA FS42R 1719E

Users Manual

     Rev A                Page 1 of 25          FS42R-1719E Dual Band Fiber Fed Outdoor Das System   Series  FS42R   User Manual   RF On Fiber ® Signal Distribution Products for Outdoor DAS Coverage Extension Applications
Fiber-Span      Rev A       Page 2 of 25     Information in this document is subject to change without notice. All rights reserved. Please send comments to:  E-mail   techinfo@fiber-span.com   PHONE: 908-253-9080 Fax: 908-253-9086  Revision History  Version Author  Description Date Release A J. Stewart   20-Jan-2010
Fiber-Span      Rev A       Page 3 of 25  Table of Contents   1. SUMMARY...............................................................................................................................................................................5 2. GENERAL DESCRIPTION......................................................................................................................................................5 3. DUAL BAND OUTDOOR DAS REMOTE FIBER NODE (RFN)  [STANDARD CONFIGURATION]..............................7 3.1 REMOTE FIBER NODE MODEL DRAWING....................................................................................................................................7 3.2 REMOTE FIBER NODE BLOCK DIAGRAM (COMMON TO ALL CONFIGURATIONS) .........................................................................7 3.3 REMOTE FIBER NODE DETAILED DESCRIPTION ..........................................................................................................................8 3.4 REMOTE FIBER NODE (RFN) EXTERNAL INTERFACES (STANDARD CONFIGURATION) ...............................................................8 3.4.1 Remote Fiber Node Interface Description .........................................................................................................................8 3.4.2 Remote Fiber Node Front Panel Drawing.........................................................................................................................9 4. DUAL BAND OUTDOOR DAS FIBER TRANSCEIVER UNIT (FTU) ................................................................................9 4.1 FIBER TRANSCEIVER UNIT MODEL DRAWING (SHOWN WITH OPTIONAL DUPLEXED INTERFACE)..............................................9 4.2 FIBER TRANSCEIVER UNIT DETAILED DESCRIPTION.................................................................................................................10 4.3 FIBER TRANSCEIVER UNIT BLOCK DIAGRAM ...........................................................................................................................11 4.4 FIBER TRANSCEIVER UNIT EXTERNAL INTERFACES (WITH OPTIONAL DUPLEXED PORTS)........................................................12 4.4.1 FTU Interface Description...............................................................................................................................................12 4.4.2 FTU Front Panel Description (show with optional  Duplexed Ports) .............................................................................12 5. DUAL BAND OUTDOOR DAS SYSTEM CONNECTIONS...............................................................................................14 6. DUAL BAND OUTDOOR DAS ELECTRICAL SPECIFICATIONS...................................................................................15 7. MONITORING & CONTROL................................................................................................................................................15 8. GRAPHIC USER INTERFACE (GUI)...................................................................................................................................16 9. MECHANICAL SPECIFICATIONS ......................................................................................................................................20 10. ENVIRONMENTAL SPECIFICATIONS ..............................................................................................................................20 11. REGULATORY STATEMENTS: ..........................................................................................................................................20 12. APPENDIX A : INSTALLATION INSTRUCTIONS............................................................................................................21 Preparing for Installation................................................................................................................................................................21 Safety Precautions ...........................................................................................................................................................................21 System  Installation..........................................................................................................................................................................23 Remote Fiber Node Installation.......................................................................................................................................................25 Remote Fiber Node Verification Testing..........................................................................................................................................25
Fiber-Span      Rev A       Page 4 of 25 List of Figures   Figure 1: DAS System Diagram ................................................................................................................................................................5 Figure 2: Dual Band Outdoor DAS System Diagram................................................................................................................................6 Figure 3: Remote Fiber Node Model Drawing ..........................................................................................................................................7 Figure 4 Remote Fiber Node Block Diagram ............................................................................................................................................7 Figure 5: Remote Fiber Node Front Panel.................................................................................................................................................9 Figure 6: FTU Model Drawing..................................................................................................................................................................9 Figure 7: FTU Block Diagram.................................................................................................................................................................11 Figure 8: FTU Front Panel.......................................................................................................................................................................12 Figure 9: FTU Front Panel Configurations..............................................................................................................................................13 Figure 10: Dual Band Outdoor DAS System Connections......................................................................................................................14 Figure 11: Fiber-Span GUI Settings Page................................................................................................................................................17 Figure 12: GUI System Performance Display Page.................................................................................................................................18 Figure 13 – System Block Diagram.........................................................................................................................................................23
Fiber-Span      Rev A       Page 5 of 25  1. Summary  This document is intended to cover the operation of the Fiber-Span Dual Band Outdoor DAS FS42R-1719E.  It provides the reader with a general description of the product and its interfaces. It contains information intended for engineers, technicians and operators working with the Dual Band Outdoor DAS.   2. General Description  The Fiber-Span fiber fed Distributed Antenna System (DAS) is a wireless optical network which can be used to expand network and capacity needs and to overcome site location constraints involving zoning issues, limited space availability or prohibitive BTS based site lease costs . It provides connectivity between a BTS site and several Remote Antenna sites through a fiber optic link. The DAS is made up of two main components; one FTU and three Remote Fiber Nodes. Shown below are the FTU and the three Remote Fiber Nodes.  The FTU is located near the BTS site and the Remote Fiber Node is located at the antenna site.  HECREMOTENODESector 1REMOTENODESector 3REMOTENODESector 2To Antenna 1To Antenna 2To Antenna 3Sector 1Sector 2Sector 3Fiber OpticLink  3Fiber OpticLink  2Fiber OpticLink  1BTS Figure 1: DAS System Diagram    The Fiber-Span Dual Band Distributed Antenna System (DAS) FS42R-1719E is a dual band version of the Fiber-Span DAS. It designed to work in the AWS band and the PCS band.    The Fiber-Span Dual Band Outdoor DAS is made-up of three main components:  1. Dual Band Remote Fiber Node (RFN) 2. PCS and AWS Band Fiber Transceiver Unit (FTU)  3.   Element manager  FTU
Fiber-Span      Rev A       Page 6 of 25 AWS HECREMOTENODESector 1REMOTENODESector 3REMOTENODEsector 2To AWSAntenna 1Fiber OpticLinkPCS HECTo PCSAntenna 1To AWSAntenna 2To PCSAntenna 2To AWSAntenna 3To PCSAntenna 3Sector 1Sector 2Sector 3AWSBTSSector 1Sector 2Sector 3PCSBTS Figure 2: Dual Band Outdoor DAS System Diagram  Remote Fiber Node:  The Remote Fiber Node is dual band; it supports AWS and PCS bands. On the UL path (RX), the Remote Fiber Node converts RF signal to optical and improves the system’s receive (Rx) noise. floor. On the DL path (TX), the Remote Fiber Node converts optical to RF and amplifies the RF output to 20Watts (43 dBm).  Fiber Transceiver Unit:   The FTU is designed as two separate units:  a PCS model and an AWS model. On the UL path (RX), it converts optical to RF.  On DL path (TX) RF to optical. The FTU also monitors and controls the network (FTU and RFN) via the Element manager.   Element Manager: This unit can monitor and control multiple DAS Systems via the FTU’s.    AWS FTU PCS FTU
Fiber-Span      Rev A       Page 7 of 25  3. Dual Band Outdoor DAS Remote Fiber Node (RFN)  [Standard Configuration]  3.1 Remote Fiber Node Model Drawing   Figure 3: Remote Fiber Node Model Drawing 3.2 Remote Fiber Node Block Diagram (Common to all configurations)   PCSOP/RFControllerPCSMCPA PCSDLNAAWSOP/RFControllerAWSMCPA AWSDLNAPOWERSUPPLYRXTXRXTXFANFAN+28V &CTRL +12V &CTRL+28V+28VPCSANTENNAAWSANTENNAFIBERPCSFIBERAWSAC 90-240V,15AETHERNET -PROPRIETARYRS485+28V &CTRL +12V &CTRL+12V & CTRL+12V & CTRL      Figure 4 Remote Fiber Node Block Diagram
Fiber-Span      Rev A       Page 8 of 25 3.3 Remote Fiber Node Detailed Description   The Remote Fiber Node is a dual band duplexer/amplifier system. On the UL path, the Remote Fiber Node amplifies the RF signal (low noise amplifier) and converts it to optical.  On the DL path (TX), the Remote Fiber Node converts the input optical signal to RF and amplifies the signal to 20Watts (power amplifier).  Following is a brief description of each module.  OP/RF Module: Converts RF to optical and optical to RF. One is used for the PCS band and a second one is used for the AWS band.  MCPA: Multi-carrier Power Amplfiier. The MCPA amplifies the RF output power to 20Watts (43dBm). Both MCPAs are multicarrier, thereby insuring optimal ACP performance.  DLNA: Duplexer/Low Noise Amplifier. The DLNA duplexes the Rx and Tx signals and is designed to amplify the RX path and improve the sysem’s noise floor.  Controller: The Controller provides power, control and monitoring to the various modules of the Remote Fiber Node. The controller also provides communication with the unit, via a GUI based application, that can be used to display information on the operating conditions and alarm conditions of the Remote Fiber Node.   3.4 Remote Fiber Node (RFN) External Interfaces (Standard Configuration) 3.4.1 Remote Fiber Node Interface Description  Interface  Description  Limits, Max. FIBER PCS  Single Mode FC ACP  Optical Input /output Port – for PCS Band Input from FTU on DL path Output to FTU on UL path  PCS ANTENNA 7/16 DIN FEMALE  RF Antenna Port – for PCS Band (RF in for UL path) (RF out for D path) Max. input Power (UL Path): 10 dBm Rated Output Power (DL path): 20Watts  FIBER AWS  Single Mode FC ACP  Optical Input /output Port – for AWS Band Input from FTU on DL path Output to FTU on UL path  AWS ANTENNA 7/16 DIN FEMALE  RF Antenna Port – for AWS Band (RF in for UL path) (RF out for DL path) Max. input Power (UL Path): 10 dBm Rated Output Power (DL path): 20Watts AC 90-250V, 15A  Power Supply Input Voltage  90 – 250 V 15 A ETHERNET PROPRETARY – RS485  RS485 Communication Port For local commisioning
Fiber-Span      Rev A       Page 9 of 25 3.4.2 Remote Fiber Node Front Panel Drawing  Fiber  PCS  Fiber AWS PCS AntennaAWS  Antenna Ethernet  RS485  AC 90-240V, 15A   N/A  Figure 5: Remote Fiber Node Front Panel 4. Dual Band Outdoor DAS Fiber Transceiver Unit (FTU)   4.1 Fiber Transceiver Unit Model Drawing (Shown with Optional Duplexed Interface)   Figure 6: FTU Model Drawing
Fiber-Span      Rev A       Page 10 of 25 4.2 Fiber Transceiver Unit Detailed Description  The Fiber Transceiver Unit (FTU) has two different functions: it converts the input optical signal to RF on the UL path (Rx), converts the RF input signal to optical on the DL path (Tx) and it also monitors and controls the network (FTU and RFN) via the Element manager. The FTU has two different input configurations: • Separate Tx & Rx: For low power compact base station with separate Rx and Tx signals, input power –5dBm to 5dBm. • Optional Diplexed Tx/Rx: For Tx/Rx diplexed signal from base station, input power 0- 43dBm. In this configuration, the FTU attenuates the RF  input to a suitable level for the fiber optic link (0dBm) on the DL path (Tx).   Following is the block diagram of the FTU and a  brief description of each module.  OP/RF Module: Converts RF to optical and optical to RF.  RF Board: On the BTS port, duplexes the Rx and Tx signals and attenuates the RF input signal to 0dBm. On the RX separate path (Rx out), it sets the gain of the Rx path. On the TX separate path ( Tx in), it sets the gain of the Tx path. Controller: The Controller provides power, control and monitoring to RF Board and OP/RF modules. The controller also provides communication with the unit via a GUI based application that can be used to display FTU information. The controller also provides communication with the Remote Fiber Node via the fiber optic link. Communication to the controller is established by an RS485 local Ethernet port.
Fiber-Span      Rev A       Page 11 of 25  4.3 Fiber Transceiver Unit Block Diagram   POWER SUPPLYCONTROLLERFANFANRXTXOP / RFRXoutRXinBTS portTXoutTXinRXTXOP / RFRXTXOP / RFRFBOARDRFBOARDRFBOARDOptical 1Optical 2Optical 31RXoutRXinBTS portTXoutTXinRXoutRXinBTS portTXoutTXin23+5V&CTRL+12V&CTRL+12V&CTRL+12V&CTRL+5V&CTRL+5V&CTRLAC 90-250V,15AETHERNET  -PROPRIETARYRS485 Figure 7: FTU Block Diagram
Fiber-Span      Rev A       Page 12 of 25 4.4 Fiber Transceiver Unit External Interfaces (with optional Duplexed Ports) 4.4.1 FTU Interface Description  Interface  Description  Limits, Max. Rxout  (1-2 and 3) SMA FEMALE  Rx output (separate Rx/Tx ; for low power compact BTS)    RXin (1-2 and 3) SMA FEMALE  RX input from RXout when using diplexed Rx/Tx Port connection.     BTS Port  (1-2 and 3) N-TYPE FEMALE  TX and RX diplexed BTS Port  Max. Input Power: 43dBm Min. Input Power: 36dBm Txout (1-2 and 3) SMA FEMALE  Tx output from BTS port when using diplexed Rx/Tx Port connection    Txin (1-2 and 3) SMA FEMALE  Tx In  (separate Rx/Tx ; for low power compact BTS)  Max. Input Power: 5dBm Min. Input Power: -5dBm Optical (1-2 and 3) FC/ACP  Optical Input /output Port  Output to RFN on TX path Input from RFN on RX path  ETHERNET  RS485 Communication Port   AC POWER IN 110/220 VAC  Input Voltage  Min. Input Voltage: 90V Max. Input Voltage : 220V   4.4.2 FTU Front Panel Description (show with optional  Duplexed Ports)   Figure 8: FTU Front Panel
Fiber-Span      Rev A       Page 13 of 25 Depending on the input configuration of the FTU, there are different connections required to the front panel :  1. TX/ RX diplexed 2. TX and RX separate   RXout RXin BTS Port TXout TXinInput from BTSconnected here.TX/RX Diplexed:TX/RX Seperate:RXout RXin BTS Port TXout TXinRx Ouput to BTSconnected here.Tx Input to BTSconnected here.TX/RX Seperate: Figure 9: FTU Front Panel Configurations
Fiber-Span      Rev A       Page 14 of 25  5. Dual Band Outdoor DAS System Connections  Following is a system connection diagram showing how to connect the 3 Remote Fiber Nodes and 2 FTUs for the Dual Band Outdoor DAS.  Connections shown with optional Duplexed input configuration.  To AWSAntenna 1From AWSBTS Sector1From AWSBTS Sector 2From AWSBTS Sector 3Fiber OpticLinksFrom PCSBTS Sector  1From PCSBTS Sector 2From PCSBTS Sector 3To PCSAntenna 1To AWSAntenna 2To PCSAntenna 2To AWSAntenna 3To PCSAntenna 3RXoutBTS Port 1RXinTXoutTXinRXoutBTS Port 2RXinTXoutTXinAWSHECRXoutBTS Port 3RXinTXoutTXinOptical 1Optical 2Optical 3FiberAWSFiberPCS PCSAntennaAWSAntennaRemoteNodeSector 1FiberAWSFiberPCS PCSAntennaAWSAntennaRemoteNodeSector 2FiberAWSFiberPCS PCSAntennaAWSAntennaRemoteNodeSector 3RXoutBTS Port 1RXinTXoutTXinRXoutBTS Port 2RXinTXoutTXinAWSHECRXoutBTS Port 3RXinTXoutTXinOptical 1Optical 2Optical 3Fiber OpticLinksAC 90-240VAC 90-240VAC 90-240VAC SupplyAC SupplyAC POWER INAC POWER IN Figure 10: Dual Band Outdoor DAS System Connections   PCS FTU AWS FTU
Fiber-Span      Rev A       Page 15 of 25 6. Dual Band Outdoor DAS Electrical Specifications   Electrical Requirements   Specification PCS  Specification AWS   DL ( TX)  PCS  AWS Frequency of Operation  1930-1900MHz  2110 – 2155 MHz RF Output Power   36 to 43 dBm  36 to 43 dBm Gain   0 dB (Factory Set 0 dB, Field Adjustable)  0 dB (Factory Set 0 dB, Field Adjustable) Emission Mask  Compliant to 3GPP2  (4xEDGE signal, spacing 600KHz) Compliant to 3GPP2  (2 x CDMA2k signals, 20 MHz instantaneous BW)     UP (Rx)  PCS  AWS Frequency of Operation  1850-1910 MHz  1710-1755 MHz Gain   6.0 dB   10 miles (13km) fiber length between FTU and RFN. 6.0 dB 10 miles (13km) fiber length between FTU and RFN Noise Figure for G<5dB  5.0 dB  5.0 dB IP3  -5 dBm  -5 dBm 7. Monitoring & Control  The system can be monitored and controlled using the RS-485 interface. Following is a list of the monitoring and control features that are available on this product.  Monitoring and Control Description & Specification  Monitoring  Description  Specification Remote Fiber Node Forward Output Power (RF)  RF Output Power level (dBm) of the Remote Fiber Node at Antenna port.   Remote Fiber Node Reflected  Power (RF)  RF Reflected Power level (dBm) of the Remote Fiber Node at Antenna Port.   Remote Fiber Node Temperature  Temperature (ºC) of the Remote Fiber Node (controller board).   ±  3 degrees  FTU Input Power (RF)  RF input power level ( dBm) at the BTS input port of the FTU.   FTU Temperature  Temperature (ºC) of the FTU (RF board).   System Gain   DL path gain (Tx) from the input to the FTU to the output of the Remote Fiber Node.        Control    Remote Fiber Node Tx Path Gain Control  User Control – The customer can adjust the gain of the Remote Fiber Node DL path (Tx) through the GUI interface.
Fiber-Span      Rev A       Page 16 of 25  Alarms     MCPA Alarm  Alarm if any of the MCPA RF devices fail.   Power Supply Alarm  Alarm if any of the power module ( DC/DC converters) fail.   Temperature Alarm  Alarm when temperature > 85 ºC.   LNA Current Alarm  Alarm if current > 200mA on the LNA of the AWS or PCS DLNA.   Default value is 200mA can be modified by user VSWR Alarm  Alarm if at antenna port of Remote Fiber Node  Forward Output Power – Refelected Power < 5dB   Fiber Optic Module Alarm  Alarm if one of the fiber optic module fails   Fan Failure Alarm  Alarm if any of the fans fail    8. Graphic User Interface (GUI)  A  Fiber-Span GUI is provided to control and monitor the performance of the Dual Band Outdoor DAS.  The GUI can be used to monitor 1 FTU and 3 Remote Fiber Nodes using a local connection.  The GUI that needs to be installed on the computer to monitor both the AWS and PCS FTUs.: DAS GUI vX.YY.exe  Following are the steps required to install and run both GUIs.  Create a folder for each AWS  and PCS  and copy the corresponding GUI inside along with a copy of DAS-Profile.ini file Install WinPcap software Connect each FTU to a hub and to PC Run both GUI from their new folders      GUI Interface – 1 FTU  In order for the GUI to communicate with the Dual Band Outdoor DAS, a cable needs to be connected between a PC/Laptop and the FTU communication port – ETHERNET port.  The FTU controller uses RS485 protocol on its ETHERNET port. The FTU communicates with the Remote Fiber Node through Fiber Optic Link, no other connection is required to the Remote Fiber Node to communicate with the GUI. The PCS GUI is required to connect to the PCS FTU and the AWS GUI is required to connect to the AWS FTU. Therefore, there are two instances of the Fiber-Span GUI running at the same time to monitor both FTUs.   Following is the snapshot of the GUI, there are two pages which are displayed on the screen: 1. Settings Page: This is the page where all the settings for the network, e-mail server, and dialy logs are entered. This is the first page to come up every time the user starts-up the GUI. It is also available from the Display Page using the “Settings”button.   2. System Performance Page: This is where the DAS system performance parameters are displayed for 1 FTU.
Fiber-Span      Rev A       Page 17 of 25  Figure 11: Fiber-Span GUI Settings Page   Geographical ID/Description: Field to describe each Remote Fiber Node that is connected to the FTU, to be able to distinguish one from the other on the display page. DAS # 1: Unit that is physically connected to Optical 1 Port.  DAS # 2: Unit that is physically connected to Optical 2 Port. DAS # 3: Unit that is physically connected to Optical 3 Port.  Email-On-Alarm Settings:  Check enable Box to Receive e-mail notification when an alarm arises. The client settings are the e-mail server settings that the customer is using for the e-mail notification.  Daily Log Settings:  Check enable Box to log the performance display page at a particular interval.  ReadMe: Not Used.
Fiber-Span      Rev A       Page 18 of 25   Figure 12: GUI System Performance Display Page  There are 4 sections on the DAS system performance page:  Head End Unit Section: System Performance parameters for the FTU  If the Head End Unit Button is Green, the communication with the FTU has been extablished.  FW Version: Firmware Version installed on the FTU Temperature: Temperature in degrees celcius of the controller inside the FTU unit. PSU: Power Supply Voltage Output    DAS Channel # 1, DAS Channel # 2 and DAS Channel # 3 Section:  Performance parameters for the 3 individual Remote Fiber Nodes.  If the DAS Channel # X is Green, the communication with the Remote Fiber Node has been established. Underneath the DAS Channel # X is the description given to the Remote Fiber Node (from settings page). FTU Status:  Attenuator # X:  Setting  for the digital attenuator of the FTU to control gain of the system.
Fiber-Span      Rev A       Page 19 of 25 Input Power (dBm): Power level in dBm  at the input of the FTU, BTS Port. FOM1 TX Alarm and FOM1 RX Alarm: Alarm from Fiber Optic Module of the FTU, Tx / RX respectively.  Remote Unit # X: Gain (dB): System Gain Calculated from the input to the FTU (BTS port) to the output of the Remote Fiber Node (Antenna Port) FWD Power (dBm): Power Level at the output of the Remote Fiber Node (Antenna Port) REV Power (dBm): Power Level of power reflected back into the unit at the output of the Remote Fiber Node (Antenna Port) Attenuator # 2: Setting  for the digital attenuator of the Remote Fiber Node to control gain of the system. PA Temperature: Temperature in degrees celcius of the MCPA inside the Remote Fiber Node unit.  Alarm List: List of Alarms currently active on the unit: FAN 1 Alarm FAN 2 Alarm
Fiber-Span      Rev A       Page 20 of 25  9. Mechanical Specifications  Mechanical  Specification  Size    26.5”H x 13.2”W x 7.3”D RF Connectors     DIN Control connector     RJ-45 Optical Connector    FC/APC Finish     Enamel Paint    10.  Environmental Specifications  Environmental  Specification   Notes Temperature of operation    -40 to +45  Warm up of 20 minutes at -40 Enclosure   IP65   11.  Regulatory Statements:  “Changes or modifications not expressly approved by the manufacturer could “Void” the user’s authority to operate the equipment”.  This device has been designated to operate with antennas having a maximum gain of [14 ] dBi for a [ 5 ] meter distance and antennas having greater values are strictly prohibited for use with this device. The required antenna impedance is [ 50 ] Ohms.
Fiber-Span      Rev A       Page 21 of 25 12. Appendix A : Installation Instructions   Preparing for Installation Before attempting to install, we recommend that you first familiarize yourself by reading through the installation instructions. Understanding the system operation will reduce the possibility of incorrect installation, thereby causing damage or injury to yourself or others. The system must be installed in accordance with the conditions and recommendations contained in the following sections. Safety Precautions Carelessness or mishandling of the DAS may damage the equipment causing serious injury to yourself or others.  All installation activity must be carried out in compliance with the safety instructions supplied with the BTS and with local standard authority warnings and precautions. Please adhere to the following:            WARNING!!            This equipment is designed for use with high power radio frequency (RF) radiating systems. Personnel must take precautions to minimize exposure to the RF  fields.            WARNING!!            The equipment is designed for use with equipment that generates high voltages. Proper precautions must be taken when working with this equipment.            CAUTION!            To prevent damage to static sensitive devices, ESD (electrostatic discharge) precautions must be observed when handling or installing the equipment. Do not tamper with, or attempt to reconfigure, the cords or plugs supplied with the hardware, as this can: ♦ result in personal injury ♦ void the warranty ♦ cause damage to the units or related equipment
Fiber-Span      Rev A       Page 22 of 25   Warranty Information Fiber-Span will warranty each product that it manufactures to be free from defects in materials and workmanship for a period of twelve (12) months. Fiber-Span’s only obligation under this warranty is to, at its option, repair or replace any product or part thereof that is returned with transportation charges prepaid to Fiber-Span by the original purchaser within one year after delivery to the original purchaser, and which, upon examination by Fiber-Span, is determined to be defective or to have failed the normal service.   Equipment Damage or Loss Fiber-Span is not responsible for damage or loss of equipment during transit.  For further information, contact the responsible transport carrier. When declaring equipment as damaged during transit, preserve the original shipping cartons to facilitate inspection reporting.  Return of Equipment All warranty returns must be authorized by the Fiber-Span Customer Service Department, which will issue a Return Material Authorization (RMA) number. This is important for prompt, efficient handling of the returned equipment and of the associated complaint    When returning equipment to Fiber-Span for repair or replacement: 1. Notify Fiber-Span Customer Service Department of the equipment condition and obtain a Return Material Authorization (RMA) number and shipping instructions at: a. Email:     sales@fiber-span.com b. Telephone:   (908) 253-9080  c. Fax:    (908) 253-9086   2. Identify, in writing, the condition of the equipment. 3. Include to the Part Number, Serial Number, Sales Order, Purchase Order and the date the equipment was received. Fiber-Span will pay for the cost of shipping the product to the customer after the repairs are completed.
Fiber-Span      Rev A       Page 23 of 25     System  Installation  DAS Remote Fiber Node System Block Diagram: BTSEquipmentSite ACSupplyDrip Loop incable toAntennaANTENNANote: System components not to scaleR E M O T ENODE Figure 13 – System Block Diagram
Fiber-Span      Rev A       Page 24 of 25  Installation Overview The flow chart below illustrates the steps required to install the DDAS Remote Fiber Node and FTU.  Details and graphic explanations for the installation steps are shown in the following detailed installation sections, as indicated. Close down the Antenna SiteIsolate the power source and ensure the site is safe.Secure Remote Node to tower or surface, as desired. by completing appropriate step sequence detailed in section 3.3.1. Connect feeder cables: *AWS Antenna port to Antenna * PCS Antenna por to Antenna * Fiber Optic Link for PCS to Fiber PCS port * Fiber Optic Link for AWS to Fiber AWS portConnect ground cable  Connect power and control cables*  Manufacture and connect AC power cable from   BTS to Remote Nocde, as required.Installation complete. Proceed to Verification TestingClose down the BTS cellIsolate the power source and ensure the site is safe.Install PCS FTU and AWS FTU in BTS Rack.Connect feeder cables: *BTS Sector 1, 2 and 3 to FTU BTS Port 1, 2 and 3. * Fiber Optic Link for PCS to PCS FTU Optical 1, 2 and 3. * Fiber Optic Link for AWS to AWS FTU Optical 1,2 and 3 port.Connect  ground cableInstallation complete. Proceed to Verification TestingConnect power and control cables*  Manufacture and connect AC power cable from   BTS to FTU AC POWER IN port, as required. * Connect BTS communication cable to FTU ETHERNET port. Remote Node FTU
Fiber-Span      Rev A       Page 25 of 25 Detailed Installation Instructions Remote Fiber Node Installation  The DAS Remote Fiber Node has been designed to be mounted outdoors directly on the antenna mast. If this is not feasible, it may be mounted on a flat wall surface as close as possible to the associated antenna.  Each DAS Remote Fiber Node comes equipped with integrated mounting brackets which are used for either installation option .         Remote Fiber Node Verification Testing  Standard site testing done by the operator includes drive testing and base station Key Performance Indicators (KPI).