Fiberstars WPC3 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1
Fiberstars, Inc. WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS WPC 1
USER MANUAL
WPC-3 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL LISTED Conforms to UL STD 508; Certified to CSA STD C22.2 No. 14 http://www.fiberstars.com 79-15097-00 REV B Page 1 of 20 The WPC-3 single speed consists of the following parts: Item 4a 4b 10 11 12 13 14 15 16 17 18 19 20 21 Qty. Component part No. 94-15106-00 94-15089-00 37-15000-00 41-15004-12 41-15004-05 42-15032-00 02-15269-00 02-15267-00 41-15003-00 94-15090-00 10-15086-04 10-15089-06 10-15060-01 10-15089-03 38-15012-00 94-15092-00 10-15089-02 20-15013-00 02-15283-00 17-15005-00 10-15089-01 43-15021-00 Description WPC-3 Enclosure WPC-3 Enclosure Door Relay 12-Position Terminal Block 5-Position Terminal Block Timer Load Center Cover Plate WPC-2 Mounting Bracket Grounding Bar WPC Receiver Load Center Cover Plate, Switch Bracket, and Mounting Bracket Screws Terminal Block Mounting Screw Relay Mounting Screw Timer Mounting Screws 3-Position Rocker Switch WPC Repeater Freeze Device Mounting Screw (Optional equipment) Strain Relief WPC-3 Timer and Switch Bracket Latch Latch Mounting Screws WPC-3 Antenna Splitter 10 21 20 10 16 19 13 4a, 4b 17 11 18 12 15 14 10 http://www.fiberstars.com 79-15097-00 REV B Page 2 of 20 The WPC-3 dual speed consists of the following parts: Item 4a 4b 10 11 12 13 14 15 16 17 18 19 20 21 22 Qty. Component part No. 94-15106-00 94-15089-00 37-15000-00 41-15004-12 41-15004-05 42-15032-00 02-15269-00 02-15267-00 41-15003-00 94-15090-00 10-15086-04 10-15089-06 10-15060-01 10-15089-03 38-15012-00 94-15092-00 10-15089-02 20-15013-00 02-15283-00 17-15005-00 10-15089-01 43-15021-00 37-15001-00 Description WPC-3 Enclosure WPC-3 Enclosure Door Relay 12-Position Terminal Block 5-Position Terminal Block Timer Load Center Cover Plate WPC-2 Mounting Bracket Grounding Bar WPC Receiver Load Center Cover Plate, Switch Bracket, and Mounting Bracket Screws Terminal Block Mounting Screw Relay Mounting Screw Timer Mounting Screws 3-Position Rocker Switch WPC Repeater Freeze Device Mounting Screw (Optional equipment) Strain Relief WPC-3 Timer and Switch Bracket Latch Latch Mounting Screws WPC-3 Antenna Splitter DPDT Relay 10 21 10 20 16 10 17 22 19 13 4a, 4b 10 11 18 14 15 12 Accessory Items: FP 1/2 WE-65 WPC-2/3 ST DL-HUB TC-2 WPC-TRANS Temperature Freeze Device 65 ft Repeater Cord Extension Kit GFCI Mounting Kit Direct Light Hub Connection Kit Additional Timeclock/Dust Cover 24V Transformer for Fiberstars Light Streams LED Products or JVA Control http://www.fiberstars.com 79-15097-00 REV B Page 3 of 20 SAVE THESE INSTRUCTIONS! IMPORTANT SAFETY INFORMATION Basic safety precautions should be observed when operating the WPC-3 product and other associated equipment. 1. A qualified electrician must install the WPC-3 in accordance to the National and Local Electrical Codes. 2. The WPC-3 must not be less then 5 feet (3 meters in Canada) from inside edge of pool. ONLY USE COPPER CONDUCTORS. 3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors. 4. For the bonding, grounding, installing, and wiring of underwater lights to the WPC-3, refer to Article 680 of the National Electrical Code or Section 68 of the Canadian Electrical Code. 5. This device should never operate an equipment that could cause property damage, bodily injury, or death should it be activated unexpectedly. 6. Never allow children to operate the WPC-3 unsupervised. FCC WARNING 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by Fiberstars Inc. could void the user's authority to operate the equipment. http://www.fiberstars.com 79-15097-00 REV B Page 4 of 20 ELECTRICAL RATINGS Do not exceed the maximum electrical ratings of the WPC-3. A circuit breaker rated at 20Amps at 120VAC must installed in the breaker panel to connect to the WPC-3 power input. Circuit 1 and Circuit 2 are each rated for use of up to 8Amps @ 120VAC. The Pump Relay is rated at a maximum of 3HP @ 240VAC. M ANUFACTURER Thomas & Bet t s Cut ler-Hammer Square D M urray Siemens/ ITE Challenger West inghouse or Bryant Crouse Hinds GE Regular SINGLE TB BR HOM M P-T QP BR MP THOP SUITABLE LISTED BREAKERS CIRCUIT BREAKER DOUBLE TWIN QUAD TB TBBD TBBQ BR BRD BRD HOM HOM T HOM T M P-T M H-T M H-T QP QT QT A-CT BQ TRIPLEX GFCB GFB GFCB HOM -GFI M P-GT QPF HAGF GFCB M P-GF THOP-GF Wiring Inf ormat ion - Copper Conduct ors Only Terminal Torque* Wire Size 75°C min. Insulat ion AWG 14 12 10 Supply Circuit Breaker Rat ing AM P 15 20 30 50 65 85 100 100/ 125 Line and Neut ral M ain Lugs LB-IN 35 35 35 40 45 45 50 50 Neut ral and Ground LB-IN 20 20 20 25 35 35 M ax M ot or Load (Cont inuous Dut y) 120V 240V HP HP 1/ 2 1 1/ 2 General Purpose Branch Circuit Breaker Rat ing AM P 15 20 30 40 60 FILLER PLATE FP-1C-TB BRFP HOM FP LX100FP QF-3 # FC-1C FP-1 TQLFP-1 General Purpose Branch Circuit M aximum Current Capacit y AM P 12 16 24 32 44 http://www.fiberstars.com 79-15097-00 REV B Page 5 of 20 WARNING • • • TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT. ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL PERSONELL ONLY. VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE. LOCATION Install the WPC-3 enclosure using the mounting plates included with each enclosure. The WPC3 is housed in a Type 3R rainproof enclosure and can be mounted anywhere between the pool equipment and the breaker panel. NOTE: If a freeze protect device is required, please see Fiberstars part no. FP 1/2. WIRING INSTRUCTIONS FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL REGULATORY REQUIREMENTS. Power Connections: To wire the WPC-3 use insulated COPPER wire only, 12 gauge minimum. Run a ½” to ¾” conduit from the main breaker panel to the WPC-3. Pull appropriate wires from the main breaker panel to the WPC-3 unit. To make power connections remove 3/8 inches of insulation from wire ends. Connect bare wires to the Load Center as illustrated. Tighten terminal screws firmly (20 lb-in minimum). Connect the common to the Neutral bar (tighten to 20 lb-in minimum). LINE - PRIMARY NEUTRAL GROUND LINE - SECONDARY http://www.fiberstars.com 79-15097-00 REV B Page 6 of 20 Power Connection with a GFCI To wire the WPC-3 with the use of a GFCI, punch out the GFCI knockout on the side of the WPC-3 enclosure. Install an outdoor rated GFCI. Using COPPER wire only, 12 gauge minimum, connect the GFCI from the LOAD side to the 120V LINE terminal. Connect the NEUTRAL from the LOAD side of the GFCI to the NEUTRAL terminal. Connect the GROUND of the GFCI to the EQUIP. GND. bar. Wire the HOT from the GFCI’s LINE side to the 20 Amp circuit breaker. Connect the NEUTRAL from the GFCI’s LINE side to the Neutral bar on the Load Center. Connect a wire from the 20 Amp circuit breaker to the T/C POWER as shown on the diagram. Connect a wire from the Neutral Bar to the T/C NEUTRAL. NEUTRAL LOAD SIDE HOT LOAD SIDE T/C POWER T/C NEUTRAL 120VAC 20AMP CIRCUIT BREAKER HOT LINE SIDE TO NEUTRAL BAR GFCI GROUND NOTE: DO NOT connect the T/C POWER and T/C NEUTRAL to the GFCI’s LOAD side. Hooking up Lights to Circuit 2 and Circuit 3 To connect a lighting product to the Circuit 2 and Circuit 3 switch, pull wires from the products to the WPC-3 through conduits connected to the bottom of the WPC-3. As illustrated, connect lights that will be operated by the Circuit 2 Switch to the Circuit 2 terminal. Connect the Neutral to the Terminal Block marked Neutral. Connect the Ground to the Equip. GND. bar. Repeat for Circuit 2. NOTE: Do not exceed 8 Amps per circuit. NOTE: The WPC-3 is approved for use with the Intermatic Metallic Hub Kit (156PA14336A) and Fiberstars DL-HUB for direct connection of underwater lights. Refer to NFPA 70 Article 680 or C22.1 Section 68 for details. http://www.fiberstars.com 79-15097-00 REV B Page 7 of 20 Connecting Jazz, Jazz-Spa, System 6004, and System 6004-AS* For proper operation of these products both Circuit 2 and Circuit 3 must be wired so that the power is controlled through Circuit 2 and the color wheels functions are controlled through Circuit 3. Follow each products installation manual for proper installation. Run appropriately rated wires from the unit to the WPC-3 no less then 12 Gauge COPPER wires. Connect the Power to the Circuit 2 terminal at one end and to the BLACK wire on the Fiberstars unit. Connect the neutral to the NEUTRAL terminal in the WPC-3 and to the WHITE wire on the Fiberstars unit. Connect the grounding cable to the EQUIP. GND. and on the other end to the GREEN cable. Finally, for synchronization operation, connect the C/W CONTROL cable to the Circuit 3 terminal and on the other end to the RED wire on the Fiberstars unit. NOTE: Do not exceed 8 Amps on Circuit 2. NEUTRAL LIGHT CONTROL C/W CONTROL NOTE: The WPC-3 is approved for use with the Intermatic Metallic Hub Kit (156PA14336A) and Fiberstars DL-HUB for direct connection of underwater lights. Refer to NFPA 70 Article 680 or C22.1 Section 68 for details. * Or other two button Power/Color system, ie. Pentair, Supervision, Fiberworks… http://www.fiberstars.com 79-15097-00 REV B Page 8 of 20 CONNECTING A 120VAC DEVICE TO CIRCUIT 1 To wire a 120VAC device to the Relay, connect the LOAD wire from the device (as illustrated) to the Relay and a 120VAC power from an appropriately rated circuit breaker using no less then a 12 gauge COPPER wire. Connect the NEUTRAL from the device directly to the NEUTRAL bar at the breaker panel (as illustrated). Alternately, you may connect the NEUTRAL from the device to the Relay and from the Relay to the NEUTRAL bar. 120V Circuit Breaker 120VAC Neutral at Subpanel Ground NOTE: The 120VAC device is not to exceed 15Amps nor 1.5HP. CONNECTING A 240VAC PUMP TO CIRCUIT 1 Connect the 240VAC pump to the relay as illustrated. Connect a 240VAC Circuit Breaker to the Load Center. Wire the Relay from the 240VAC Circuit Breaker as illustrated. NOTE: 240V Pump not to exceed 30amps nor 3HP. 240V Circuit Breaker 240VAC Pump http://www.fiberstars.com 79-15097-00 REV B Page 9 of 20 PUMP CONNECTIONS NOTE: Some models are ONLY equipped with Single Speed OR Dual Speed pump connections. CONNECTING A 240VAC PUMP Connect the 240VAC pump to the relay as illustrated. Connect a 240VAC Circuit Breaker to the Load Center. Wire the Relay from the 240VAC Circuit Breaker as illustrated. NOTE: 240V Pump not to exceed 30amps nor 3HP. 240V Circuit Breaker 240VAC Pump POWER IN LO SPEED NOTE: The Secondary 120V must be directly connected to the pump for 240V operation. HI SPEED CONNECTING A 2-SPEED PUMP As illustrated, connect the Low Speed wire to the Low Speed Load terminal on the terminal block. Connect the High Speed wire to the High Speed Load terminal on the terminal block. Connect the 120V Primary from the 240V Circuit Breaker to the 120V PRI INPUT terminal. Directly connect the 120V Secondary from the Circuit Breaker to the 2 Speed Pump. 120V PRIMARY 240VAC CIRCUIT BREAKER 2 SPEED PUMP 120V SECONDARY CONNECTED TO 2 SPEED PUMP NOTE: Pump Breaker MUST be turned OFF before servicing as 2nd leg of 240V circuit is HOT at all time! http://www.fiberstars.com 79-15097-00 REV B Page 10 of 20 24V Valve Wiring (Optional Equipment). To connect a 24V Valve, follow diagram as shown. Connect one leg of the 24V common to the 24V TO VALVE terminal. Connect the Close wire to the NC LOAD terminal and the Open wire to the NO LOAD terminal. NOTE: In the Pool/Spa Combo units (WPC3-??4?-?, where ? = any number), there maybe two (2) JVA connections. See JVA Installation and Operational manual for JVA synchronization methods. COMMON TO VALVE CLOSE WIRE FROM VALVE OPEN WIRE FROM VALVE Heater Connection (Optional Equipment). To connect a heater, run the pilot wires from the heater to the WPC unit. Connect the wires to the terminal block labeled Heater. NOTE: The Heater circuit only completes the circuit of the Heater terminals when the 24V Valve control is energized to the NO Load circuit. TO HEATER TO HEATER http://www.fiberstars.com 79-15097-00 REV B Page 11 of 20 SINGLE SPEED INTERNAL WIRING SCHEMATIC FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION FOR USE WITH TC-2 OPTION FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION FOR USE WITH TC-2 OPTION http://www.fiberstars.com 79-15097-00 REV B Page 12 of 20 DUAL SPEED INTERNAL WIRING SCHEMATIC FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION FOR USE WITH TC-2 OPTION FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION FOR USE WITH TC-2 OPTION http://www.fiberstars.com 79-15097-00 REV B Page 13 of 20 Repeater Mounting The WPC-3 is equipped with a signal repeater that can be mounted up to 10 feet from the WPC-3 unit. This repeater receives signals from the wireless remote and sends that signal to the WPC-3 via the 10 foot cable. Establish a location for the Repeater that is in line of sight from where the wireless remote will be used most frequently and that is no more then 75 feet from furthest where the remote will be used. NOTE: If extension is needed, use Fiberstars part number WE-65 and follow installation instructions supplied with the Repeater Extension. To mount the Repeater, carefully insert a small flathead screwdriver into groove between the Dome and Base approximately where the locking dimples are located. Pry the Dome out of the locking dimples. Then carefully insert the small flathead screwdriver into the groove between the Dome and the Base in an adjacent locking dimple and pry the Dome out. Then separate the Dome from the Base by hand. Using the supplied self-drilling screws, locate a suitable mounting surface and screw the base to this surface. Note that the marking “TOP” must be in the 12 o’clock position and the wire slit must be in the 6 o’clock position. Do not over tighten the screws as it may damage the Repeater base. Realign the Repeater Dome to the Base and ensure that the wire is exiting the base through the slit and the Locking Dimples are aligned with the locking holes. Apply enough pressure so that the Dome “snaps” into the base. NOTE: Do not stuff the remainder of the Repeater wire into the WPC unit. Flathead Screwdriver Repeater Dome/Base groove 10 feet Locking Dimple Mounting Screws Orientation Marker Mounting Holes Repeater Dome Base Slit for Repeater Wire Repeater Base http://www.fiberstars.com 79-15097-00 REV B Page 14 of 20 OPERATING INSTRUCTIONS WPC-3 ROCKER SWITCH OPERATION The WPC-3 receiver box houses three rocker switches. For operation with the wireless transmitter, the switches need to be in the DOWN or REMOTE position. To manually turn ON the devices connected to Circuit 1, Circuit 2, or Circuit 3, flip the rocker switches UP or to the ON position. When a circuit is in the ON position, the Wireless Remote will not be able to turn OFF the respective circuit. To turn OFF the devices manually, flip the respective toggle switch to the MIDDLE or OFF position. NOTE: In the OFF position, the wireless remote operation will be bypassed. To re-enable the wireless remote operation, flip the toggle switch back to the BOTTOM or REMOTE position. NOTE: If the units turn ON when the switch is returned to the REMOTE position, simply use the wireless remote to turn OFF the units if desired. WIRELESS REMOTE OPERATION NOTE: The rocker switches on the WPC-3 must be set to REMOTE for wireless operation. The POWER ON/OFF buttons control the individual circuits independently. With each push of the button, the WPC-3 toggles the individual circuits from ON to OFF and vice versa. For Synchronization operation, simply push the SYNC ON/OFF button. NOTE: If all circuits are off when the SYNC ON/OFF button is pressed, all circuits will be turned to ON. If any one of the circuits are in the ON state by the wireless remote, then when the SYNC ON/OFF button is pressed all circuits will be turned OFF and the SYNC ON/OFF must be pressed to turn all circuits on simultaneously. NOTE: Switch is shown in the ON position. Circuit 1 control Circuit 2 control Circuit 3 control NOTE: Synchronization is for Circuits 2 and 3 only. NOTE: For Dual Speed models, Pump switch operates Hi Speed only. For Synchronization of Circuit 2 and Circuit 3 http://www.fiberstars.com 79-15097-00 REV B Page 15 of 20 OPERATION INSTRUCTIONS FOR POOL/SPA COMBO OPTION WIRELESS REMOTE OPERATION NOTE: The rocker switches on the WPC-3 must be set to REMOTE for wireless operation. The SPA ON/OFF button actuates the JVA valves and the Filter pump as well as turn on the Heater. If the Filter pump is already in the ON position by the time clock, then just the JVA valves will be actuated to the SPA position and the Heater will be turned ON. The Pool Light button turns ON and OFF the Pool Light with each push of the button. The SPA Light button turns ON and OFF the SPA Light with each push of the button. For Synchronization operation, simply push the SYNC ON/OFF button to turn ON and OFF the SPA Light and the Pool Light simultaneously. If one of the lights is on when the SYNC button is pressed, that light will turn OFF and the SYNC button will have to be pressed once again to turn both SPA and Pool Lights ON. NOTE: If all circuits are off when the SYNC ON/OFF button is pressed, all circuits will be turned to ON. If any one of the circuits are in the ON state by the wireless remote, then when the SYNC ON/OFF button is pressed all circuits will be turned OFF and the SYNC ON/OFF must be pressed to turn all circuits on simultaneously. NOTE: Synchronization is for Pool Light and Spa Light only. NOTE: For Dual Speed models, the SPA ON/OFF button actuates the Hi Speed pump while actuating the JVA valves. http://www.fiberstars.com 79-15097-00 REV B Page 16 of 20 TIMER OPERATION Set time to current time. Open timer cover by lifting from the bottom towards you. In the example below, the current time is set for 9:00 pm. NOTE: Only turn the Timer dial clockwise or the timer will be damaged. Once the time has been set to the current time, set the hours of the Pump operation by “snapping” the timer tabs inwards towards the center. NOTE: Each tab represents 15 minutes of operation and tabs set inwards towards the center is for OFF operations and ON when the tabs are set outwards as illustrated. In the example below, the Pump will be off from 12:00 pm to 11:45 pm. Once the time and time of operation has been set, ensure that the Timer function switch is set to Auto for timer control of the Pump as illustrated below. To turn off timers automatic functions, set the Timer function switch to OFF. To manually turn on the Pump, set the Timer function switch to the ON position. NOTE: When in the ON position, the Pump will continue to run until the Timer function switch is set to Auto where the tabs at the Set Point is in the OFF position or if the Timer function switch is rotated to the OFF position. Apply the timer label to the timer cover plate. Close the timer cover firmly after timer is set. Timer Cover Timer Plate Timer tabs set to ON position Timer dial rotation direction indicator Single Speed Shown Timer tabs set to OFF position Current time and Timer function switch set point PM hours AM hours Timer function switch Timer dial http://www.fiberstars.com 79-15097-00 REV B Page 17 of 20 CODE ADJUSTMENTS If it is necessary to change the transmission code on the WPC-3 an adjustment to the two receivers AND the transmitter DIP switches must be performed. RECEIVER DIP SWITCHES – Turn OFF power to the WPC-3 from the circuit breaker on the Load Center or from Main Power. Open the enclosure door. Unscrew and remove the Load Center Cover Plate. Place the Cover Bracket in a safe location. Unscrew and remover the Switch Bracket. Disconnect the Molex connector that connects the Switch Bracket controls to the receiver unit and set the Switch Bracket in a safe location where it will not be bent, scratched, or impact forces applied to the components or the face plate itself [Notes: There maybe more then one Molex connector that must be disconnected]. Unscrew the four (4) screws holding the two Receivers to the base of the WPC-3 enclosure [NOTE: Do not lose the spacers]. Unscrew the four (4) screws located on the back of each receiver to release the cover. NOTE: Take notice of how the wires enter and exit the receiver and which receiver is connected to the Circuit 2 and Circuit 3 terminals on the terminal block. Remove the cover and look on the PCB to locate the DIP switch as illustrated. TRANSMITTER DIP SWITCHES – Remove all screws from rear of remote. Separate the bottom cover from the top cover. DIP SWITCH ADJUSTMENT – On each Receiver, there is a four (4) position DIP switch and on the Transmitter there is a three (3) position DIP switch. On the receivers, the DIP switches 1 through 3 must be set identically to each other and the Transmitter. Changing just one DIP switch will change the code. The fourth (4th) DIP switch on the receivers determine the Primary and Secondary roles of the PCB’s. The two receivers MUST have the fourth (4th) DIP switch set differently from one another. When the fourth (4th) DIP switch is in the ON position, then it will receive the Pump and Circuit 1 signal and when in the OFF position, it will receive the Circuit 2, Circuit 3, and Synchronization signals from the remote. Ensure that the Receiver with the fourth (4th) DIP switch ON is connected to the Pump and Circuit 1 Relays and that the Receiver with the fourth (4th) DIP switch OFF is connected to the Circuit 2 and Circuit 3 terminals on the Terminal Block. Molex Connector Receiver Mounting Screws Spacers Bracket Spacer Switch Bracket Bracket Spacer Terminal Block Two Receivers Mounting Screws Load Center Cover Plate Receiver screws http://www.fiberstars.com 79-15097-00 REV B Page 18 of 20 DIP SWITCH SETTINGS DIP SWITCH Rear screws DIP Switch Note: Sample shown is of Channel 8. DIP SWIT CH Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON OFF OFF ON ON OFF OFF OFF OFF ON ON ON ON CHANNEL 13 10 14 11 15 12 16 NOTE: ONLY CHANNELS 1 THROUGH 8 ARE AVAILABLE FOR THE WPC-3. Fourth (4th) DIP switch DIP switch Optional Equipped Units WPC3-XXXX-1 : Single Speed with Freeze Protect. WPC3-2XXX-1 : Dual Speed with Freeze Protect. No additional wiring required. No additional wiring required. http://www.fiberstars.com 79-15097-00 REV B Page 19 of 20 WPC FUNCTION CHART Below is a chart of the WPC functionality based on the model number. WPC3 Pump Features Button 2 Features Pump Button Features Other Options X – Standard 1 – Load Center Removed X – Standard 2 – One JVA Valve Switching 4 – Two JVA Valve Switching for Pool/Spa combo w/HTR control Accessories X – Standard 1 – Freeze Protect 2 – T/C w/Relay for Pool Cleaner Booster Pump 5 – FP & T/C w/Relay for Pool Cleaner Pump X – Standard 3 – WFPR added for Booster Pump X –1 Speed Pump – Standard 3 – 2 Speed Pump w/T.C. for Lo Speed & T.C. for Hi Speed EXAMPLE: WPC3-3X2X-1 is a 2 speed pump model with two time clocks (one to control High Speed and one to control Low Speed). Pump Button turns ON High Speed pump regardless of timer position and activates the JVA valve. This unit is also equipped with a Freeze Protection device that will activate High Speed pump operation at 34°F and resume normal operation at 39°F. http://www.fiberstars.com 79-15097-00 REV B Page 20 of 20
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 20 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:4b0415db-f0d1-4a4d-a40c-eb31cdbea2ab Producer : Acrobat Distiller 6.0 (Windows) Company : FIBERSTARS Source Modified : D:20070719171002 Headline : Creator Tool : Acrobat PDFMaker 6.0 for Word Modify Date : 2007:07:19 13:11:49-04:00 Create Date : 2007:07:19 13:10:12-04:00 Metadata Date : 2007:07:19 13:11:49-04:00 Document ID : uuid:db73c476-a35e-4e6b-bde4-7316b34694f9 Version ID : 4 Format : application/pdf Title : WPC-1 Creator : FIBERSTARS Subject : Tagged PDF : Yes Author : FIBERSTARSEXIF Metadata provided by EXIF.tools