Fiberstars WPC3 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1

Fiberstars, Inc. WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS WPC 1

USER MANUAL

Download: Fiberstars WPC3 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1
Mirror Download [FCC.gov]Fiberstars WPC3 WIRELESS CONTROLLER FOR SWIMMING POOL PERIPHERALS User Manual WPC 1
Document ID829695
Application IDucGvxd/8KPi0hegYcKwpSQ==
Document DescriptionUSER MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize119.87kB (1498389 bits)
Date Submitted2007-08-15 00:00:00
Date Available2007-08-16 00:00:00
Creation Date2007-07-19 13:10:12
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2007-07-19 13:11:49
Document TitleWPC-1
Document CreatorAcrobat PDFMaker 6.0 for Word
Document Author: FIBERSTARS

WPC-3
Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications
Installation Instructions: Read these instructions in
their entirety before performing any installation work.
FOR USE WITH POOL AND SPA PRODUCTS
ETL LISTED
Conforms to UL STD 508;
Certified to CSA STD
C22.2 No. 14
http://www.fiberstars.com
79-15097-00 REV B
Page 1 of 20
The WPC-3 single speed consists of the following parts:
Item
4a
4b
10
11
12
13
14
15
16
17
18
19
20
21
Qty.
Component part No.
94-15106-00
94-15089-00
37-15000-00
41-15004-12
41-15004-05
42-15032-00
02-15269-00
02-15267-00
41-15003-00
94-15090-00
10-15086-04
10-15089-06
10-15060-01
10-15089-03
38-15012-00
94-15092-00
10-15089-02
20-15013-00
02-15283-00
17-15005-00
10-15089-01
43-15021-00
Description
WPC-3 Enclosure
WPC-3 Enclosure Door
Relay
12-Position Terminal Block
5-Position Terminal Block
Timer
Load Center Cover Plate
WPC-2 Mounting Bracket
Grounding Bar
WPC Receiver
Load Center Cover Plate, Switch Bracket, and Mounting Bracket Screws
Terminal Block Mounting Screw
Relay Mounting Screw
Timer Mounting Screws
3-Position Rocker Switch
WPC Repeater
Freeze Device Mounting Screw (Optional equipment)
Strain Relief
WPC-3 Timer and Switch Bracket
Latch
Latch Mounting Screws
WPC-3 Antenna Splitter
10
21
20
10
16
19
13
4a, 4b
17
11
18
12
15
14
10
http://www.fiberstars.com
79-15097-00 REV B
Page 2 of 20
The WPC-3 dual speed consists of the following parts:
Item
4a
4b
10
11
12
13
14
15
16
17
18
19
20
21
22
Qty.
Component part No.
94-15106-00
94-15089-00
37-15000-00
41-15004-12
41-15004-05
42-15032-00
02-15269-00
02-15267-00
41-15003-00
94-15090-00
10-15086-04
10-15089-06
10-15060-01
10-15089-03
38-15012-00
94-15092-00
10-15089-02
20-15013-00
02-15283-00
17-15005-00
10-15089-01
43-15021-00
37-15001-00
Description
WPC-3 Enclosure
WPC-3 Enclosure Door
Relay
12-Position Terminal Block
5-Position Terminal Block
Timer
Load Center Cover Plate
WPC-2 Mounting Bracket
Grounding Bar
WPC Receiver
Load Center Cover Plate, Switch Bracket, and Mounting Bracket Screws
Terminal Block Mounting Screw
Relay Mounting Screw
Timer Mounting Screws
3-Position Rocker Switch
WPC Repeater
Freeze Device Mounting Screw (Optional equipment)
Strain Relief
WPC-3 Timer and Switch Bracket
Latch
Latch Mounting Screws
WPC-3 Antenna Splitter
DPDT Relay
10
21
10
20
16
10
17
22
19
13
4a, 4b
10
11
18
14
15
12
Accessory Items:
FP 1/2
WE-65
WPC-2/3 ST
DL-HUB
TC-2
WPC-TRANS
Temperature Freeze Device
65 ft Repeater Cord Extension Kit
GFCI Mounting Kit
Direct Light Hub Connection Kit
Additional Timeclock/Dust Cover
24V Transformer for Fiberstars Light Streams LED Products or JVA Control
http://www.fiberstars.com
79-15097-00 REV B
Page 3 of 20
SAVE THESE INSTRUCTIONS!
IMPORTANT SAFETY INFORMATION
Basic safety precautions should be observed when operating the WPC-3 product and other
associated equipment.
1. A qualified electrician must install the WPC-3 in accordance to the National and Local Electrical
Codes.
2. The WPC-3 must not be less then 5 feet (3 meters in Canada) from inside edge of pool. ONLY
USE COPPER CONDUCTORS.
3. Do not exceed the maximum ratings of individual components, wiring devices, and current
carrying capacity of conductors.
4. For the bonding, grounding, installing, and wiring of underwater lights to the WPC-3, refer to
Article 680 of the National Electrical Code or Section 68 of the Canadian Electrical Code.
5. This device should never operate an equipment that could cause property damage, bodily injury,
or death should it be activated unexpectedly.
6. Never allow children to operate the WPC-3 unsupervised.
FCC WARNING
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
2. Changes or modifications not expressly approved by Fiberstars Inc. could void the user's
authority to operate the equipment.
http://www.fiberstars.com
79-15097-00 REV B
Page 4 of 20
ELECTRICAL RATINGS
Do not exceed the maximum electrical ratings of the WPC-3. A circuit breaker rated at
20Amps at 120VAC must installed in the breaker panel to connect to the WPC-3 power input.
Circuit 1 and Circuit 2 are each rated for use of up to 8Amps @ 120VAC. The Pump Relay is
rated at a maximum of 3HP @ 240VAC.
M ANUFACTURER
Thomas & Bet t s
Cut ler-Hammer
Square D
M urray
Siemens/ ITE
Challenger
West inghouse or Bryant
Crouse Hinds
GE Regular
SINGLE
TB
BR
HOM
M P-T
QP
BR
MP
THOP
SUITABLE LISTED BREAKERS
CIRCUIT BREAKER
DOUBLE
TWIN
QUAD
TB
TBBD
TBBQ
BR
BRD
BRD
HOM
HOM T
HOM T
M P-T
M H-T
M H-T
QP
QT
QT
A-CT
BQ
TRIPLEX
GFCB
GFB
GFCB
HOM -GFI
M P-GT
QPF
HAGF
GFCB
M P-GF
THOP-GF
Wiring Inf ormat ion - Copper Conduct ors Only
Terminal Torque*
Wire Size
75°C min.
Insulat ion
AWG
14
12
10
Supply
Circuit
Breaker
Rat ing
AM P
15
20
30
50
65
85
100
100/ 125
Line and
Neut ral
M ain
Lugs
LB-IN
35
35
35
40
45
45
50
50
Neut ral
and
Ground
LB-IN
20
20
20
25
35
35
M ax M ot or Load
(Cont inuous Dut y)
120V
240V
HP
HP
1/ 2
1 1/ 2
General
Purpose
Branch
Circuit
Breaker
Rat ing
AM P
15
20
30
40
60
FILLER PLATE
FP-1C-TB
BRFP
HOM FP
LX100FP
QF-3
# FC-1C
FP-1
TQLFP-1
General
Purpose
Branch
Circuit
M aximum
Current
Capacit y
AM P
12
16
24
32
44
http://www.fiberstars.com
79-15097-00 REV B
Page 5 of 20
WARNING
•
•
•
TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT.
ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY
QUALIFIED ELECTRICAL PERSONELL ONLY.
VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE.
LOCATION
Install the WPC-3 enclosure using the mounting plates included with each enclosure. The WPC3 is housed in a Type 3R rainproof enclosure and can be mounted anywhere between the pool
equipment and the breaker panel.
NOTE: If a freeze protect device is required, please see Fiberstars part no. FP 1/2.
WIRING INSTRUCTIONS
FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL
REGULATORY REQUIREMENTS.
Power Connections:
To wire the WPC-3 use insulated
COPPER wire only, 12 gauge minimum.
Run a ½” to ¾” conduit from the main
breaker panel to the WPC-3. Pull
appropriate wires from the main breaker
panel to the WPC-3 unit. To make
power connections remove 3/8 inches of
insulation from wire ends. Connect bare
wires to the Load Center as illustrated.
Tighten terminal screws firmly (20 lb-in
minimum). Connect the common to the
Neutral bar (tighten to 20 lb-in
minimum).
LINE - PRIMARY
NEUTRAL
GROUND
LINE - SECONDARY
http://www.fiberstars.com
79-15097-00 REV B
Page 6 of 20
Power Connection with a GFCI
To wire the WPC-3 with the use of a
GFCI, punch out the GFCI knockout
on the side of the WPC-3 enclosure.
Install an outdoor rated GFCI. Using
COPPER wire only, 12 gauge
minimum, connect the GFCI from the
LOAD side to the 120V LINE
terminal. Connect the NEUTRAL
from the LOAD side of the GFCI to
the NEUTRAL terminal. Connect the
GROUND of the GFCI to the EQUIP.
GND. bar. Wire the HOT from the
GFCI’s LINE side to the 20 Amp
circuit breaker.
Connect the
NEUTRAL from the GFCI’s LINE
side to the Neutral bar on the Load
Center. Connect a wire from the 20
Amp circuit breaker to the T/C
POWER as shown on the diagram.
Connect a wire from the Neutral Bar
to the T/C NEUTRAL.
NEUTRAL
LOAD SIDE
HOT
LOAD SIDE
T/C POWER
T/C
NEUTRAL
120VAC 20AMP
CIRCUIT BREAKER
HOT
LINE SIDE
TO
NEUTRAL BAR
GFCI
GROUND
NOTE: DO NOT connect the T/C
POWER and T/C NEUTRAL to the
GFCI’s LOAD side.
Hooking up Lights to Circuit 2 and
Circuit 3
To connect a lighting product to the
Circuit 2 and Circuit 3 switch, pull
wires from the products to the WPC-3
through conduits connected to the
bottom of the WPC-3. As illustrated,
connect lights that will be operated by
the Circuit 2 Switch to the Circuit 2
terminal. Connect the Neutral to the
Terminal Block marked Neutral.
Connect the Ground to the Equip.
GND. bar. Repeat for Circuit 2.
NOTE: Do not exceed 8 Amps per
circuit.
NOTE: The WPC-3 is approved for use with the Intermatic Metallic Hub Kit
(156PA14336A) and Fiberstars DL-HUB for direct connection of underwater lights.
Refer to NFPA 70 Article 680 or C22.1 Section 68 for details.
http://www.fiberstars.com
79-15097-00 REV B
Page 7 of 20
Connecting Jazz, Jazz-Spa, System 6004, and System 6004-AS*
For proper operation of these products both Circuit 2 and Circuit 3 must be wired so that the
power is controlled through Circuit 2 and the color wheels functions are controlled through
Circuit 3. Follow each products installation manual for proper installation. Run appropriately
rated wires from the unit to the WPC-3 no less then 12 Gauge COPPER wires. Connect the
Power to the Circuit 2 terminal at one end and to the BLACK wire on the Fiberstars unit.
Connect the neutral to the NEUTRAL terminal in the WPC-3 and to the WHITE wire on the
Fiberstars unit. Connect the grounding cable to the EQUIP. GND. and on the other end to the
GREEN cable. Finally, for synchronization operation, connect the C/W CONTROL cable to
the Circuit 3 terminal and on the other end to the RED wire on the Fiberstars unit.
NOTE: Do not exceed 8 Amps on Circuit 2.
NEUTRAL
LIGHT CONTROL
C/W CONTROL
NOTE: The WPC-3 is approved for use with the Intermatic
Metallic Hub Kit (156PA14336A) and Fiberstars DL-HUB
for direct connection of underwater lights. Refer to NFPA
70 Article 680 or C22.1 Section 68 for details.
* Or other two button Power/Color system, ie. Pentair, Supervision, Fiberworks…
http://www.fiberstars.com
79-15097-00 REV B
Page 8 of 20
CONNECTING A 120VAC DEVICE
TO CIRCUIT 1
To wire a 120VAC device to the Relay,
connect the LOAD wire from the device
(as illustrated) to the Relay and a
120VAC power from an appropriately
rated circuit breaker using no less then a
12 gauge COPPER wire. Connect the
NEUTRAL from the device directly to
the NEUTRAL bar at the breaker panel
(as illustrated). Alternately, you may
connect the NEUTRAL from the device
to the Relay and from the Relay to the
NEUTRAL bar.
120V Circuit Breaker
120VAC
Neutral at Subpanel
Ground
NOTE: The 120VAC device is not to
exceed 15Amps nor 1.5HP.
CONNECTING A 240VAC PUMP TO
CIRCUIT 1
Connect the 240VAC pump to the relay
as illustrated. Connect a 240VAC Circuit
Breaker to the Load Center. Wire the
Relay from the 240VAC Circuit Breaker
as illustrated.
NOTE: 240V Pump not to exceed
30amps nor 3HP.
240V Circuit
Breaker
240VAC Pump
http://www.fiberstars.com
79-15097-00 REV B
Page 9 of 20
PUMP CONNECTIONS
NOTE: Some models are ONLY equipped with Single Speed OR Dual Speed pump
connections.
CONNECTING A 240VAC PUMP
Connect the 240VAC pump to the relay
as illustrated.
Connect a 240VAC
Circuit Breaker to the Load Center.
Wire the Relay from the 240VAC
Circuit Breaker as illustrated.
NOTE: 240V Pump not to exceed
30amps nor 3HP.
240V Circuit
Breaker
240VAC Pump
POWER IN
LO SPEED
NOTE: The Secondary 120V must be
directly connected to the
pump for 240V operation.
HI SPEED
CONNECTING A 2-SPEED PUMP
As illustrated, connect the Low Speed
wire to the Low Speed Load terminal on
the terminal block. Connect the High
Speed wire to the High Speed Load
terminal on the terminal block. Connect
the 120V Primary from the 240V Circuit
Breaker to the 120V PRI INPUT
terminal. Directly connect the 120V
Secondary from the Circuit Breaker to
the 2 Speed Pump.
120V PRIMARY
240VAC CIRCUIT
BREAKER
2 SPEED PUMP
120V SECONDARY CONNECTED
TO 2 SPEED PUMP
NOTE: Pump Breaker MUST be turned OFF
before servicing as 2nd leg of 240V
circuit is HOT at all time!
http://www.fiberstars.com
79-15097-00 REV B
Page 10 of 20
24V Valve Wiring (Optional Equipment).
To connect a 24V Valve, follow diagram as
shown. Connect one leg of the 24V common
to the 24V TO VALVE terminal. Connect
the Close wire to the NC LOAD terminal and
the Open wire to the NO LOAD terminal.
NOTE: In the Pool/Spa Combo units
(WPC3-??4?-?, where ? = any number),
there maybe two (2) JVA connections. See
JVA Installation and Operational manual
for JVA synchronization methods.
COMMON TO VALVE
CLOSE WIRE FROM VALVE
OPEN WIRE FROM VALVE
Heater Connection (Optional Equipment).
To connect a heater, run the pilot wires from
the heater to the WPC unit. Connect the wires
to the terminal block labeled Heater.
NOTE: The Heater circuit only completes
the circuit of the Heater terminals when the
24V Valve control is energized to the NO
Load circuit.
TO HEATER
TO HEATER
http://www.fiberstars.com
79-15097-00 REV B
Page 11 of 20
SINGLE SPEED INTERNAL WIRING SCHEMATIC
FOR TEMPERATURE
FREEZE PROTECT
SWITCH OPTION
FOR USE WITH
TC-2 OPTION
FOR TEMPERATURE
FREEZE PROTECT
SWITCH OPTION
FOR USE WITH
TC-2 OPTION
http://www.fiberstars.com
79-15097-00 REV B
Page 12 of 20
DUAL SPEED INTERNAL WIRING SCHEMATIC
FOR TEMPERATURE
FREEZE PROTECT
SWITCH OPTION
FOR USE WITH
TC-2 OPTION
FOR TEMPERATURE
FREEZE PROTECT
SWITCH OPTION
FOR USE WITH
TC-2 OPTION
http://www.fiberstars.com
79-15097-00 REV B
Page 13 of 20
Repeater Mounting
The WPC-3 is equipped with a signal repeater that can be mounted up to 10 feet from the WPC-3
unit. This repeater receives signals from the wireless remote and sends that signal to the WPC-3
via the 10 foot cable. Establish a location for the Repeater that is in line of sight from where the
wireless remote will be used most frequently and that is no more then 75 feet from furthest where
the remote will be used. NOTE: If extension is needed, use Fiberstars part number WE-65
and follow installation instructions supplied with the Repeater Extension.
To mount the Repeater, carefully insert a small flathead screwdriver into groove between the
Dome and Base approximately where the locking dimples are located. Pry the Dome out of the
locking dimples. Then carefully insert the small flathead screwdriver into the groove between the
Dome and the Base in an adjacent locking dimple and pry the Dome out. Then separate the Dome
from the Base by hand. Using the supplied self-drilling screws, locate a suitable mounting
surface and screw the base to this surface. Note that the marking “TOP” must be in the 12
o’clock position and the wire slit must be in the 6 o’clock position. Do not over tighten the
screws as it may damage the Repeater base. Realign the Repeater Dome to the Base and ensure
that the wire is exiting the base through the slit and the Locking Dimples are aligned with the
locking holes. Apply enough pressure so that the Dome “snaps” into the base.
NOTE: Do not stuff the remainder of the Repeater wire into the WPC unit.
Flathead Screwdriver
Repeater
Dome/Base groove
10 feet
Locking
Dimple
Mounting Screws
Orientation
Marker
Mounting
Holes
Repeater Dome
Base Slit for
Repeater Wire
Repeater Base
http://www.fiberstars.com
79-15097-00 REV B
Page 14 of 20
OPERATING INSTRUCTIONS
WPC-3 ROCKER SWITCH OPERATION
The WPC-3 receiver box houses three rocker switches.
For operation with the wireless transmitter, the switches
need to be in the DOWN or REMOTE position. To
manually turn ON the devices connected to Circuit 1,
Circuit 2, or Circuit 3, flip the rocker switches UP or to
the ON position. When a circuit is in the ON position,
the Wireless Remote will not be able to turn OFF the
respective circuit. To turn OFF the devices manually,
flip the respective toggle switch to the MIDDLE or OFF
position.
NOTE:
In the OFF position, the wireless remote
operation will be bypassed. To re-enable the
wireless remote operation, flip the toggle switch
back to the BOTTOM or REMOTE position.
NOTE:
If the units turn ON when the switch is returned
to the REMOTE position, simply use the wireless
remote to turn OFF the units if desired.
WIRELESS REMOTE OPERATION
NOTE: The rocker switches on the WPC-3 must be set
to REMOTE for wireless operation. The POWER
ON/OFF buttons control the individual circuits
independently. With each push of the button, the
WPC-3 toggles the individual circuits from ON to OFF
and vice versa. For Synchronization operation, simply
push the SYNC ON/OFF button.
NOTE:
If all circuits are off when the SYNC ON/OFF
button is pressed, all circuits will be turned to
ON. If any one of the circuits are in the ON
state by the wireless remote, then when the
SYNC ON/OFF button is pressed all circuits will
be turned OFF and the SYNC ON/OFF must be
pressed to turn all circuits on simultaneously.
NOTE: Switch is shown in the ON position.
Circuit 1 control
Circuit 2 control
Circuit 3 control
NOTE:
Synchronization is for Circuits 2 and 3 only.
NOTE:
For Dual Speed models, Pump switch operates
Hi Speed only.
For Synchronization of
Circuit 2 and Circuit 3
http://www.fiberstars.com
79-15097-00 REV B
Page 15 of 20
OPERATION INSTRUCTIONS
FOR POOL/SPA COMBO OPTION
WIRELESS REMOTE OPERATION
NOTE: The rocker switches on the WPC-3 must be set
to REMOTE for wireless operation. The SPA ON/OFF
button actuates the JVA valves and the Filter pump as
well as turn on the Heater. If the Filter pump is already
in the ON position by the time clock, then just the JVA
valves will be actuated to the SPA position and the
Heater will be turned ON.
The Pool Light button turns ON and OFF the Pool
Light with each push of the button.
The SPA Light button turns ON and OFF the SPA
Light with each push of the button.
For Synchronization operation, simply push the SYNC
ON/OFF button to turn ON and OFF the SPA Light and
the Pool Light simultaneously. If one of the lights is on
when the SYNC button is pressed, that light will turn
OFF and the SYNC button will have to be pressed once
again to turn both SPA and Pool Lights ON.
NOTE:
If all circuits are off when the SYNC ON/OFF
button is pressed, all circuits will be turned to
ON. If any one of the circuits are in the ON
state by the wireless remote, then when the
SYNC ON/OFF button is pressed all circuits will
be turned OFF and the SYNC ON/OFF must be
pressed to turn all circuits on simultaneously.
NOTE:
Synchronization is for Pool Light and Spa Light
only.
NOTE:
For Dual Speed models, the SPA ON/OFF
button actuates the Hi Speed pump while
actuating the JVA valves.
http://www.fiberstars.com
79-15097-00 REV B
Page 16 of 20
TIMER OPERATION
Set time to current time. Open timer cover by lifting from the bottom towards you. In the
example below, the current time is set for 9:00 pm. NOTE: Only turn the Timer dial
clockwise or the timer will be damaged. Once the time has been set to the current time, set
the hours of the Pump operation by “snapping” the timer tabs inwards towards the center.
NOTE: Each tab represents 15 minutes of operation and tabs set inwards towards the
center is for OFF operations and ON when the tabs are set outwards as illustrated. In
the example below, the Pump will be off from 12:00 pm to 11:45 pm.
Once the time and time of operation has been set, ensure that the Timer function switch is set to
Auto for timer control of the Pump as illustrated below. To turn off timers automatic functions,
set the Timer function switch to OFF. To manually turn on the Pump, set the Timer function
switch to the ON position. NOTE: When in the ON position, the Pump will continue to run
until the Timer function switch is set to Auto where the tabs at the Set Point is in the
OFF position or if the Timer function switch is rotated to the OFF position. Apply the
timer label to the timer cover plate. Close the timer cover firmly after timer is set.
Timer Cover
Timer Plate
Timer tabs set to
ON position
Timer dial rotation
direction indicator
Single Speed Shown
Timer tabs set to
OFF position
Current time and Timer
function switch set point
PM hours
AM hours
Timer function
switch
Timer dial
http://www.fiberstars.com
79-15097-00 REV B
Page 17 of 20
CODE ADJUSTMENTS
If it is necessary to change the transmission code on the WPC-3 an adjustment to the two receivers AND the
transmitter DIP switches must be performed.
RECEIVER DIP SWITCHES – Turn OFF power to the WPC-3 from the circuit breaker on the Load Center or
from Main Power. Open the enclosure door. Unscrew and remove the Load Center Cover Plate. Place the Cover
Bracket in a safe location. Unscrew and remover the Switch Bracket. Disconnect the Molex connector that connects
the Switch Bracket controls to the receiver unit and set the Switch Bracket in a safe location where it will not be bent,
scratched, or impact forces applied to the components or the face plate itself [Notes: There maybe more then one
Molex connector that must be disconnected]. Unscrew the four (4) screws holding the two Receivers to the base
of the WPC-3 enclosure [NOTE: Do not lose the spacers]. Unscrew the four (4) screws located on the back of each
receiver to release the cover. NOTE: Take notice of how the wires enter and exit the receiver and which receiver
is connected to the Circuit 2 and Circuit 3 terminals on the terminal block. Remove the cover and look on the
PCB to locate the DIP switch as illustrated.
TRANSMITTER DIP SWITCHES – Remove all screws from rear of remote. Separate the bottom cover from the
top cover.
DIP SWITCH ADJUSTMENT – On each Receiver, there is a four (4) position DIP switch and on the Transmitter
there is a three (3) position DIP switch. On the receivers, the DIP switches 1 through 3 must be set identically to each
other and the Transmitter. Changing just one DIP switch will change the code. The fourth (4th) DIP switch on the
receivers determine the Primary and Secondary roles of the PCB’s. The two receivers MUST have the fourth (4th)
DIP switch set differently from one another. When the fourth (4th) DIP switch is in the ON position, then it will
receive the Pump and Circuit 1 signal and when in the OFF position, it will receive the Circuit 2, Circuit 3, and
Synchronization signals from the remote. Ensure that the Receiver with the fourth (4th) DIP switch ON is connected
to the Pump and Circuit 1 Relays and that the Receiver with the fourth (4th) DIP switch OFF is connected to the
Circuit 2 and Circuit 3 terminals on the Terminal Block.
Molex Connector
Receiver Mounting
Screws
Spacers
Bracket Spacer
Switch Bracket
Bracket Spacer
Terminal Block
Two
Receivers
Mounting
Screws
Load Center
Cover Plate
Receiver
screws
http://www.fiberstars.com
79-15097-00 REV B
Page 18 of 20
DIP SWITCH SETTINGS
DIP SWITCH
Rear screws
DIP Switch
Note: Sample shown is of Channel 8.
DIP SWIT CH
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
CHANNEL
13
10
14
11
15
12
16
NOTE: ONLY CHANNELS 1 THROUGH 8
ARE AVAILABLE FOR THE WPC-3.
Fourth (4th) DIP switch
DIP switch
Optional Equipped Units
WPC3-XXXX-1 : Single Speed with Freeze Protect.
WPC3-2XXX-1 : Dual Speed with Freeze Protect.
No additional wiring required.
No additional wiring required.
http://www.fiberstars.com
79-15097-00 REV B
Page 19 of 20
WPC FUNCTION CHART
Below is a chart of the WPC functionality based on the model number.
WPC3
Pump
Features
Button 2
Features
†
†
Pump Button
Features
†
Other
Options
†
X – Standard
1 – Load Center
Removed
X – Standard
2 – One JVA Valve Switching
4 – Two JVA Valve Switching for
Pool/Spa combo w/HTR control
Accessories
†
X – Standard
1 – Freeze Protect
2 – T/C w/Relay for Pool
Cleaner Booster Pump
5 – FP & T/C w/Relay
for Pool Cleaner
Pump
X – Standard
3 – WFPR added for Booster
Pump
X –1 Speed Pump – Standard
3 – 2 Speed Pump w/T.C. for Lo Speed &
T.C. for Hi Speed
EXAMPLE:
WPC3-3X2X-1 is a 2 speed pump model with two time clocks (one to control High Speed and
one to control Low Speed). Pump Button turns ON High Speed pump regardless of timer
position and activates the JVA valve. This unit is also equipped with a Freeze Protection device
that will activate High Speed pump operation at 34°F and resume normal operation at 39°F.
http://www.fiberstars.com
79-15097-00 REV B
Page 20 of 20

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 20
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:4b0415db-f0d1-4a4d-a40c-eb31cdbea2ab
Producer                        : Acrobat Distiller 6.0 (Windows)
Company                         : FIBERSTARS
Source Modified                 : D:20070719171002
Headline                        : 
Creator Tool                    : Acrobat PDFMaker 6.0 for Word
Modify Date                     : 2007:07:19 13:11:49-04:00
Create Date                     : 2007:07:19 13:10:12-04:00
Metadata Date                   : 2007:07:19 13:11:49-04:00
Document ID                     : uuid:db73c476-a35e-4e6b-bde4-7316b34694f9
Version ID                      : 4
Format                          : application/pdf
Title                           : WPC-1
Creator                         : FIBERSTARS
Subject                         : 
Tagged PDF                      : Yes
Author                          : FIBERSTARS
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VF2-WPC3

Navigation menu