User Manual: Fisher & Paykel DD24DCX7-88637-A DD24DCX7-88637-A FISHER & PAYKEL DISHWASHER - Manuals and Guides View the owners manual for your FISHER & PAYKEL DISHWASHER #DD24DCX788637A. Home:FISHER & PAYKEL:/ Dishwasher Parts:FISHER & PAYKEL dishwasher parts:#DD24DCX788637A FISHER & PAYKEL dishwasher parts:#DD24DCX788637A FISHER & PAYKEL dishwasher manual
Open the PDF directly: View PDF
.
Page Count: 20
| Download | |
| Open PDF In Browser | View PDF |
iNSTALLATiON
iNSTRUCTiONS
DishDrawer
TM
dishwasher
DD24D 7 & DD24DT 7 models
US CA
Fisher Paykel
_90204D
04'/3
FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL
STANDARD
HEIGHT DOUBLE
CIassic
TALL HEIGHT DOUBLE' MODELS
MODELS
Designer
Integrated
DD24DCX7
DD24DCW7
DD24DCB7
E]
DD24DI7
DD24DDFX'7
Designer
CIassic
ooo
Integrated
/
ooo
DD24DCTX7
DD24DCHTX7
DD24DCTW7
DD24DCTB7
DD24DTI7
DD24DHTJ7
DD24DDFTX'7
ooo
F
000
i
PARTS
]
SUPPLIED
OPTIONALLY
HARD
PARTS
WIRING
OPTIONA
SUPPLIED
PARTS
SUPPLIED
OPTIONALLY
LLY HA RD WIRING
HARD
PARTS
WIRING
SUPPLIED
OPTIONALLY
HARD
T
PARTS SUPPLIED
WIRING
OPTIONALLY
HARD
PARTS SUPPLIED
OPTIONALLY
WIRING
HARD
WIRING
M
PRODUCT
& CABINETRY
DIMENSIONS
(STANDARD
CAVITY
PRODUCT
HEIGHT)
PREPARATION
& CABINETRY
DIMENSIONS
(STANDARD
CAVITY
PRODUCT
HEIGHT)
PREPARATION
& CABINETRY
DIMENSIONS
CUSTOM
(STANDARD
PANEL
PRODUCT
HEIGHT)
& CABINETRY
DIMENSIONS
PRODUCT
(TALL HEIGHT)
CA VITY PREPA RATION
CALCULATIONS
& CABINETRY
DIMENSIONS
CAVITY
PRODUCT
(TALL HEIGHT)
& CABINETRY
DIMENSIONS
PREPARATION
CUSTOM
(TALL HEIGHT)
PANEL
CALCULATIONS
m
MAXIMUM
DISTANCE
& CORD FROM
OF HOSES
CHASSIS
,L
l
EDGE
MAXIMUM
DISTANCE
& CORD FROM
]
OF HOSES
CHASSIS
SECURE WITHOUT
SECURE BY
DRAWER REMOVAL DRAWER REMOVAL
RECOMMENDED
RECOMMENDED
METHOD
(a)
METHOD
(b)
METHOD
J
T
DRAINAGE
CONNECT
DISTANCE
& CORD FROM
TO WATER & ELECTRICITY
(a)
METHOD
(b)
FINAL CHECKLIST
CHOO5E
DRAINAGE
CONNECT
SECURE BY
DRAWER REMOVAL DRAWER REMOVAL
TROUBLESHOOTING
DISTANCE
FROM
i
f
METHOD
MAXIMUM
DISTANCE
& CORD FROM
1
OF HOSES
CHASSIS
MAXIMUM
f
RECOMMENDED
RECOMMENDED
METHOD
ALTERNATIVE
(a)
METHOD
L
(b)
METHOD
J
7
DISTANCE
& CORD
FROM
(a)
METHOD
(b)
[
SECURE WITHOUT
SECUREBY
DRAWER REMOVAL DRAWER REMOVAL
RECOMMENDED
CHOO5E
OPTION
OF HOSES
CHASSIS EDGE
ALTERNATIVE
L
CHOO5E
(b)
CA VITY PREPA RATION
EDGE
SECURE WITHOUT
SECUREBY
DRAWER REMOVAL DRAWER REMOVAL
ALTERNATIVE
(a)
OF HOSES
CHASSIS EDGE
SECUREWITHOUT
SECUREBY
DRAWER REMOVAL DRAWER REMOVAL
DRAINAGE
DRAINAGE
METHOD
ALTERNATIVE
(_)
METHOD
OPTION
PANELS
CHOOSE
DRAINAGE
CONNECT
TO WATER & ELECTRICITY
FINAL
CHECKLIST
TO WATER & ELECTRICITY
FINAL
TO WATER & ELECTRICIT_
FINAL CHECKLIST
TROUBLESHOOTING
INSTALL THE FRONT
CHECKLIST
OPTION
TROUBLESHOOTING
PANELS
CHOOSE
DRAINAGE
TROUBLESHOOTING
CONNECT
CONNECT
(b)
J
W
INSTALL THE FRONT
CHECKLIST
l
TROUBLESHOOTING
METHOD
OPTION
TO WATER & ELECTRICITY
FINAL
EDGE
[
SECURE WITHOUT
RECOMMENDED
OPTION
OF HOSES
CHASSIS
ALTERNATIVE
L
CHOOSE
MAXIMUM
& CORD
MAXIMUM
f
SECURE WITHOUT
SECURE BY
DRAWER REMOVAL DRAWER REMOVAL
ALTERNATIVE
CA VITY PREPA RATION
EDGE
CONNECT
OPTION
TO WATER & ELECTRICITY
FINAL
CHECKLIST
TROUBLESHOOTING
SAFETY AND WARNINGS-ALL
Electrical
3
MODELS
installation
hazard
Before installing the dishwasher, remove the house fuse or open the circuit
breaker. If permanently
connecting the dishwasher, be sure the power is isolated
and the dishwasher unplugged.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of a malfunction
or breakdown,
grounding
wi[[ reduce the risk of electric shock by providing a path of least
resistance for electric current. This appliance is equipped with a cord having
an equipment-grounding
conductor and a grounding
plug. The plug must be
plugged into an appropriate
outlet that is installed and grounded in accordance
with all local codes and ordinances. WARNING - Improper connection
of the
equipment-grounding
conductor can result in a risk of electric shock. Check with
a qualified electrician or service representative
if you are in doubt as to whether
the appliance is properly grounded.
If the dishwasher is installed as a permanently
connected appliance:
GROUNDING INSTRUCTIONS -This appliance must be connected to a grounded
metal, permanent wiring system, or an equipment-grounding
conductor must
be run with the circuit conductors
and connected to the equipment-grounding
terminal or lead on the appliance.
Do not modify the power supply plug provided with the appliance - if it will not
fit the outlet, have a proper outlet installed by a qualified electrician.
Do not use
an extension cord, adapter plug or multiple outlet box.
Failure to follow
of this dishwasher
requires
Be sure to leave these instructions
this advice may result in electrical
installation
must comply
At the completion
Remove
This dishwasher
Ensure
materials
electrician
to ensure
The dishwasher
The switched
installation,
supplied
is manufactured
all water connections
for indoor
are turned
MUST be installed
outlet
skills.
electricity,
and plumbing
the installer
must perform
regulations.
the Final Checklist.
with the dishwasher
use only.
OFF. it is the responsibility
that each installation
power
and electrical
complies
to allow for future
must be outside
of the plum ber and
with all Codes and Regulations.
removal
the dishwasher
from the enclosure
cavity,
if service
so that it is accessible
is required.
after
installation.
Care should
be taken
when
the appliance
the power supply
cord and hoses.
ff the dishwasher
is to be relocated
damage
is installed
or removed
from one installation
to reduce the likelihood
to another
of damage
it must be kept upright
to avoid
from water spillage.
Make sure only new hoses
are used for connection
(supplied
with the dishwasher).
Old hoses should
not be reused.
Failure to install the dishwasher
ff the product
is installed
boat or mobile
technician's
shock or death.
with your local building,
of the dishwasher
all packaging
basic mechanical
with the Customer
facility
correctly
in a motor
containing
travel to the location
could invalidate
vehide,
the product
any warranty
boat or similar mobile
to the service
or liability
claims.
facility, you must
shop at your expense
bring the vehicle,
or pay the service
of the product.
SAVETHESEINSTRUCTIONS
Cut hazard
Take care - panel edges are sharp.
Failure to use caution
ADDITIONAL
could
result in injury
or cuts.
SAFETY AND WARNINGS-
INTEGRATED MODELS ONLY
Read these instructions
Electrical Shock Hazard
Ensure
WARNING: To reduce the risk of electrical shock, fire, or injury to persons, the
installer must ensure that the dishwasher
is completely
enclosed at the time
of installation.
Before fitting the front panels, make sure that the dishwasher is disconnected
from the power supply.After
installing the front panels, the installer must
ensure that the following components
are electrically grounded: the panel
bracket and any custom metal component
(e.g. handle) that extends past the
rubber sea[.
Failure to follow
these warnings
may result in electrical
shock, injury
or fire.
the product
completely
is not plugged
Installation
of custom
installation
must comply
Failure to install
panels
and careful_yo
in.
requires
basic mechanical
with your local building
the custom
panels
SAVETHESEINSTRUCTIONS
correctly
and electrical
and electricity
could invalidate
skills.
regulations.
any warranty
or liability
claims.
to
4
PARTS SUPPLIED ° ALL MODELS
Drain hose
support (1)
Moisture protection
tape (1)
.
(to prevent mois[ure
damage)
ADDITIONAL
Drain hose
joiner (1)
Wire clip (2)
(for securing
Drain hosejoiner)
Hexagonal
socket for feet
adjustment (2)
(long & short)
Prefinished toekick
(attached to product)
(1)
Side mounting
bracket kit
(A and B) (2)
OPTIONAL
Edge Protector
Top
mounting
brackets (2)
OPTIONAL
(1)
PARTS SUPPLIED WITH INTEGRATED MODELS
Toekick mounting
bracket (1)
(A custom toekickpanel of any
material with thickness
_"-_" (9 - 19 ram) can be screwed
to the plastic toekick mounting
bracket)
Phillips
%" (16 mm)
screws (9)
Rubber
washer for
inlet hose (1)
(comes already
fitted)
/f the Droin hosessupplied ore not long enough
to reoch your services,you must use o Droin Hose
f!_'tensionKit P/N 525Y98 which will extend the droin
hosesby 11' 70" (Zdm).
fhe kit is ovoi/ob/e from the neorest Fisher& PoyM/
Authorized _Serviced2nter, or fb// free 1.888.93d./872
or www.fisherpoykel.com
(If the services hole is through
a metal partition the hole
must be protected with the
Edge protector supplied to
prevent damage to the power
cord or hosesJ
Panel mounting
screws (12)
Panel bracket (2)
Clamp (1)
(for securing
Drain hose joiner)
Toekick
mounting
screws (5)
Q
_
OPTIONALLY HARD WIRING PRIOR TO INSTALLATION
REMOVE THE LOWER DRAWER
REMOVE THE ACCESS COVER & POWER CORD
Access
cover
To prevent kinked hoses, we recommend
rotating the drawer anti-clockwise
and
resting it on its side after removal.
/
Press the release tabs in on
either side and push back
to release drawer from
Electrical
Shock Hazard
Before continuing,
disconnected
from
ensure that the product
the power
supply.
is
runners.
Failure to follow
electrical
shock,
this warning
may
injury
or fire.
result
in
\\
TERMINATE THE WIRING AS SHOWN
Remove knock-out for cable clamp and
fit a suitable cable clamp for the conduit.
REFIT THE DRAWER ONTO THE RUNNERS & CLOSE
tabs
, release
;'(1O0ram)
Ensure the drawer
is now rotated
clockwise back.
Before refitting the drawer,
ensure the hoses are not
twisted and the latches at
the rear of each drawer
runner are facing forward.
\\
Use copper
conductors
only.
Ensure the release tabs on
both sides are reset fully.
6
( 5( PRODUCT DIMENSIONS
n_
K
I
Plan
A
Product dimensions
Side
STANDARD HEf,GH'T'MODEL,_
inches(mm)
F
depth of front panel (exc hande)
G
height ofchassis
1 1/8"(29)
31
H
heightof levelling
feet
I
depth of handle
J
depth of toekick recess(toback of
Y8 - 2
front
panel)1
K
height of upper front
L
ventiDtion
M
height of toekick
N
height of drawer fronts
0
height from top of handle to top of front panel
pane[
gap between
D C
front panels
panel (adjustabk?)
UnchdesXJ'(2mm) high bracket slots 2dependingon adjustment of levelingfeet
3_6
-
3
11A6"(18)
31
I%6"(811)
?_LL HE#GH'T' MODELS
% - 1¾6"(16-20)
1 Y8"(29)
31 15_6"(811)
15Z6"(811)
1¼6"(18)
331¼6"(855)
331¼6"(855)
3/8 - 2 11_6"(9-69)2
11_6"(9-69) 2
3/8 - 2 11_6"(9-69) 2
3/8 - 2 11_6"(9-69)2
3/8- 2 11_6"(9-69)2
3/8- 2 11_6"(9-69) 2
n/a
1%"(41)
n/a
n/a
1%"(41)
s/8"(30-92)
15 1/2"(394)
¾6"(5)
2 % - 4 3_"(70-120)
291¾6"(757)
n/a
1
3_6
-
3
1
5/8"(30-92)
15 1¼6"(398)
546t'(8)
2 % - 4 3/4"(70-120)
30"(762)
3_6
-
3
5_6"(30-84)
5
1
3_6
-
3
5/8"(30-92)
3
5/8"(30-92)
n/a
1
3_6
-
3
5_6"(30-84)
5
17 1/4"(438)
17 3/8"(442)
min. 17 3/8"(442)
346"(5)
sA6"(8)
min. sA6"(8)
2 3_ _ 4 3_"(70-120)
2 % - 4 3/4"(70-120)
291¼6"(754)
29 lSA6"(760)
2 % - 4 3_"(70-120)
n/a
dee:p,
-
min. sA6"(8)
n/a
_assumingfFont_:s_ne[
thicknessof 1}46'(18mm) _adjustableto match toekick recesson adjoining cabinetry
Sassumingthat toekick mounting bracketis used with a %/'(18ram) thick custom panel; if _'ecess
isbetwe_:n1 _'_J'-3%/'(50 and tY/_ram)
3_6
min. 15 11A6"(398)
min. 28 1/4"(717)
2 Y2"(64)
1
% - lSA6"(16-20)
331¼6"(855)
the panel will need to be cut out - seestep 'Custompanel calcuDtion{
2
1/2"(64)
2 % - 4 3_"(70-120)
min. 29 lSA6"(760)
n/a
CABINETRY DIMENSIONS
Q
Plan
Side
Minimum
clearances
from adjacent
rain. W'(13 mm)
clearancefrom a
corner cupboard --_____,_
:........... H_ .
Cabinetry dimensions
STANDARD
inches (mm)
P
inside height of c_vity _
Q
inside width of cavity
23 %"(600)
R
inside depth of cavity
rain. 22 ¼o"(s60)
S
recommended
T
heightoftoekickspace _
height of adjacent
_dependin9 on adjustment oflevelin9 feet
rain. 32 %o"(820)
cabinet
space
30"(762)
23/8-43A'(60-120)
HE_GH'T' MODEL,_
min. 32 sAo"(820)
23 %"(600)
min. 22 ¼o"(560)
30"(762)
23/8-43/4"(60-120)
'T_LLHE_GH'T'
MODEL,_
min. 32 sAo"(820)
23 %"(600)
rain. 22 ¼6"(560)
min. 28 3/8"(720)
3_sA6-6sA6"(lO0-160)
rain. 34"(864)
23 %"(600)
rnin. 22 ¼o"(s60)
min. 34"(864)
23 %"(600)
rnin. 22 ¼o"(s60)
rain. 34"(864)
23 %"(600)
rnin. 22 Ho"(s60)
30"(762)
30"(762)
min, 30"(762)
3_sA6-6sA6"(lO0-160)
3_sA6-6sA6"(lO0-160)
3_sA6-6sA6"(lO0-160)
cabinetry
min. ho" (2 ram)
clearance
-'-'---_-_.to
adjacent
_upboard
door
8
7(7(STANDARD HEIGHT INTEGRATED MODELS ONLY- CUSTOM PANEL CALCULATIONS
The following
calculations
assume the top of the upper panel is
aligned with the top of the adjacent
panel/cabinetry
alignment
FRONT PANEL SPECiFiCATiONS
cabinetry. The final
is achieved by adjusting
the feet:
%- 13A6"(16-20 ram) panel thickness
Adequately
WIDTH OF ALL PANELS
Measure A (the width between adjacent door/drawer fronts)
and write it in the first box below, then complete the equation.
Maximum
sealed to withstand
moisture
(122%/50°C
\
@ 80% RH)
weight of each panel: 20 Ib (9 kg)
TOEKICK PANEL SPECiFiCATiONS
rain. 3/8"(9 ram) panel thickness if using supplied screws
Adequately sealed to withstand moisture (122°F/50°C @80% RH)
You may choose to affix your custom toekick panel either by
screwing it to the supplied mounting bracket or gluing it on the
supplied prefinished toekick panel.
A
min_ _,_J'(2mm)
HEIGHT OFTHE UPPER PANEL
l mino _46"(2mm)
Note: The 'upper panel extension' B allows for the top of the upper
panel to extend above the chassiswhere required.
mino5/i_"(Smm)
_ ventfladon
HEmGHT OF THE LOWER PANEL
Measure C (door/drawer height (or equivalent)) and write it in the
first box below, then complete the equation.
HEmGHT OF THE TOEKJCK PANEL
Measure D (height from the top of adjacent cabinet door fronts to the floor)
and write it in the first box below, then complete the equation.
If the toekick recess (dimension
J under 'Product dimensions') is
between 2" and 3 _" (50 and 84
mm) deep, the toekick panel will
need to be modified for fitting
around the underside of the
product.
See illustration
for details on the
shape of the cutout required.
17" (432 ram)
R _/_"(1Z7 ram)
g@
9
TALL HEIGHT INTEGRATED MODELS ONLY- CUSTOM PANEL CALCULATIONS
The following
calculations
assume the top of the upper panel is
FRONT PANEL SPECiFiCATiONS
aligned with the top of the adjacen t cabinetry. The final
panel/cabinetry
alignment
is achieved by adjusting
the feet:
%- 13A6"(16-20 ram) panel thickness
Adequately
WIDTH OF ALL PANELS
Measure A (the width between adjacent door/drawer fronts)
and write it in the first box below, then complete the equation.
Maximum
sealed to withstand
moisture
(122%/50°C
\
@ 80% RH)
weight of each panel: 20 Ib (9 kg)
TOEKICK PANEL SPECiFiCATiONS
rain. 3/8"(9 ram) panel thickness if using supplied screws
Adequately sealed to withstand moisture (122°F/50°C @80% RH)
You may choose to affix your custom toekick panel either by
screwing it to the supplied mounting bracket or gluing it on the
supplied prefinished toekick panel.
A
min_ _,_J'(2mm)
HEIGHT OFTHE UPPER PANEL
l mino _46"(2mm)
Note: The 'upper panel extension' B allows for the top of the upper
panel to extend above the chassiswhere required.
mino5/i_"(Smm)
_ ventfladon
HEmGHT OF THE LOWER PANEL
Measure (:: (door/drawer height (or equivalent)) and write it in the
first box below, then complete the equation.
HEmGHT OF THE TOEKJCK PANEL
Measure D (height from the top of adjacent cabinet door fronts to the floor)
and write it in the first box below, then complete the equation.
If the toekick recess (dimension
J under 'Product dimensions') is
between 2" and 3 _" (50 and 84
mm) deep, the toekick panel will
need to be modified for fitting
around the underside of the
product.
See illustration
for details on the
shape of the cutout required.
17" (432 ram)
R _/_"(1Z7 ram)
g@
10
CAWTY PREPARATION
lmportand
Thepower outlet must be
located in a cabinet adjacent
to the dishwasher cavity.
ii!i
....
3 ,
(10mm)
Moisture
protection
110-120VAC max. 15 A
Water Connection
t a
Recommended HOT
(Maximum 140°F/60°C).
These marks indicate
formed bracket screw
locations, if securing
by drawer removal.
......
i
i
suit %" (9 mm) male
compression fitting.
Supplied hose to
Water Pressure
Water softener models
Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)
If there is no side
partition, you
can construct
timber bracing
as something to
secure into.
max,
(450
O max. 11/2"(38mm)
\
÷
\
Can be located either side of dishwasher, preferably
at the bottom of the cavity, as shown. If adequate
clearance, services hole can be made higher to clear
toekick space. If hole is higher, ensure drain hose(s)
are routed straight into the waste connection.
- If the hole is through wood, make sure its edges
are smooth and rounded.
- If the hole is through metal, ensure you fit the
supplied Edge Protector to prevent damage to the
power cord.
Kosher requirements
\
\
Services hole
Models without water softener
Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)
Drains will need to be
separated to satisfy
kosher requirements.
We suggest you confirm
acceptability with your
local rabbi in respect to
kosher installations.
(_
MAXIMUM
11
DISTANCE OF HOSES & CORD FROM CHASSIS EDGE
Left hand side
Drain hoses - 78 ½" (2000 mm)
Right hand side
Drain hoses - 70 ½" (7800 mm)
Inlet hose _ 64 _" (7650 mm)
Power cord (exd. plug)
Power cord (excLplug) - 27 ½" (700 mm)
@
12
NOW CHOOSE WHICH INSTALLATION METHOD (a)
IS MORE SUITABLE FOR YOUR CABINETRY...
RECOMMENDED
_
ATTACH SIDE MOUNTING
METHOD
(a) ° SECURE WnTHOUT
BRACKETS
Clip all four side mounting brackets into
their slots using a flat-bladed screwdriver.
Ensure they're securely fitted before
sliding product into cavity.
DRAWER
(_
REMOVAL
(FRAMELESS CABINETRY ONLY}
PULL THROUGH HOSES & PUSH INTO THE CAWTY
optionally
(x2)
attach the
two top mounting
brackets
Ensure the product is level
The mounting slots are in pairs, one on each side
diagonally across the product. A bracket must
match A slot and B bracket must match B slot.
You can raise or lower the product
by twisting the feet. Then take
care when pushing the product
into the cavity that you do not
bend the feet.
Asyou push product in, pull
through hoses and cord,
ensuring they don't get
kinked or twisted.
(_
@OPTIONALLY SECURE TO THE CABINETRY ABOVE
SECURE TO THE CABINETRY ON THE SIDES
x2)
Open the
drawer halfway.
Using a fiat-bladed
13
The top mounting
brackets will only bend
upwards a maximum
of 3/8"(10 mm).
Replace the gray
rubber plug back into
the trim moulding
and ensure the trim
seal is facing forward.
Using a small Philips
screwdriver,
screw through the trim
moulding, securing the
side mounting bracket
to the cabinetry.
Do not damage the
rubber trimseal.
Repeat for all
four brackets.
@FIT THE SUPPLIED
TOEKlCK PANEL (OPTIONAL FORINTEGRATED
MODELS)
Where the toekick
meets the bottom
ofthetubis
the
cut-off point
Moun ring rail
Lay the toekick fac'e down on
a chopping board or simlllar
Turn the toekick over and
score along the same line
Smooth the edge with a file.
Be careful of sharp edges.
Slide the toeklck onto
the mounting rails
either side and screw
the toekick onto the
bottom of tub on
either side.
)oint
Importand
a pencil
Score along with a knife
Gently snap off the excess
Snap off the two end tabs
Do not overtighten screw.
15
ALTERNATnVE
(_
METHOD
PULL THROUGH HOSES & PUSH iNTO THE CAWTY
(b) o SECURE BY DRAWER
O
REMOVAL
REMOVE THE LOWER DRAWER
To prevent kinked hoses, we recommend
rotating the drawer counter-clockwise and
resting it on its side after removal.
optionally
(x2)
attach the
two top mounting
brackets
_i;;;iiii_!iiiiHiiiiiiiiii_
¸
You can initially level the product
%
4' (100mm)
You can raise or lower the
product by twisting the
feet.Then take care when
pushing the product into
the cavity that you do not
bend the feet.
As you push product in, pull
through hoses and cord,
ensuring they don't get
kinked or twisted.
Press the release tabs in on either
side and push back to release
drawer from runners.
Push drawer runners back in.
_
SECURE TO THE CABINETRY ON THE SIDES
To access the side brackets,
you might have to push aside
the insulation. After securing,
ensure the sound insulation is
repositioned correctly.
For further adjustment,
using the most appropriate
length Hexagonal socket
supplied, fully extend
leveling feet up to required
distance by hand.
_
Ensure product is level and
aligning with cabinetry.
REFIT THE DRAWER ONTO THE RUNNERS
Ensure the drawer
is now rotated
clockwise back.
Before refitting the drawer,
ensure the hoses are not
twisted and the latches at
the rear of each drawer
runner are facing forward.
Ensure the release tabs on
both sides are reset fully.
SECURE TO THE CABINETRY ABOVE
x2)
Secure using two pairs
of formed brackets
(use _" (16 mm)
screws). Repeat on
the other side of the
chassis.
Hexagonal
socket
@ OPTIONALLY
16
The top mounting
brackets will only bend
upwards a maximum of
3/8"(10mm).
_
HT THE SUPPLED
17
TOEKlCK PANEL (OPTIONAL FORINTEGRATED
MODELS)
Where the toekick
meets the bottom
of the tubisthe
cut-off point
Mounting roil
Lay the toekick fac'e down on
a chopping board or simlllar
Turn the toekick over and
score along the same line
Smooth the edge with a file.
Be careful of sharp edges.
Slide the toeklck onto
the mounting rails
either side and screw
the toekick onto the
bottom of tub on
either side.
his point
e toekick
a pencil
/mportand
Score along with a knife
Gently snap off the excess
Snap off the two end tabs
Do not overtiqhten screw.
INTEGRATED MODELS ONLY o INSTALLING THE FRONT PANELS
®
REMOVE BRACKETS FROM PRODUCT
(i@ ATTACH PANELS TO PANEL BRACKETS
Electrical Shock Hazard
Before continuing,
disconnected
from
Failure to follow
electrical
shock,
ensure that the product
the power supply.
this warning
injury or fire.
may
result
18
There must be at least
3 screws used each side
is
in
Important!
Break off and discard
the tab at the top
of the Lower Panel
Bracket.
Align bottom of panels
with bottom of brackets
®
GROUND THE PANELS
(_
ATTACH PANELS TO PRODUCT
Important!
Ensure the rubber seal
between
the drawer
and panels
is kept in
place.
!
A •
Repeat for the other drawer
Electrical
I
Repeat for the other drawer
Shock Hazard
To ground (earth) the panel bracket, connect
the ground (earth) wire from the product to
one of the tabs. Any custom metal component
(e.g. handle) that extends past the rubber seal
must be grounded (earthed) too.
Failure to follow these warnings
electrical shock, injury or fire.
may result in
When refitting the
door pins,
ensure they are
orientated as shown.
INTEGRATED MODELS ONLY ° INSTALLING THE FRONT PANELS
(_
ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS
(_
19
FITTING A CUSTOM TOEKICK PANEL
,%" (16mm) x5
+ or-
_6"
@
With the front panels fitted, insert an appropriately
sized Philips screwdriver into the hole above the door
pin and rotate the panels up or down to align the gaps
in your cabinetry.
Repeat on the other side if necessary.
Each panel has a maximum travel of_A6"(2 mm) up or
down.
Important!
Ensurethatyou maintain a minimum of _6" (8 mm)
ventilation gap between the upper and lower panels.
You can optionally glue your
custom toekick panel onto the
supplied panel
@THERE ARE
Dishwasher
THREE DIFFERENT DRAINAGE OPTIONS. CHOOSE WHICH iS MORE SUITABLE.
and Standpipe
0 1½" (38 mm)
Dishwasher
using Air Break with Drain Hose Joiner
2O
Dishwasher using sink trap with drain hose joiner
If space is limited
for fixinq, push
hose through drain
hose support to
required height
If space is limited
for fixing, push
hose through drain
hose support
to required height
Supplied drain hosejoiner
0 _" (19 ram) waste tee
373_ "
(950mm)
Max.
height
to top of
Air Break
@CONNECT iNLET HOSE TO HOT
HIGHLOOP
min. 6"
i
(150 mm)
Ensure drain hose is routed straight
to joiner. Remove excess drain hose
material if necessary.
Do not shorten the inlet hose.
WATER
2_ SWITCH PRODUCT ON
Tighten coupling with wrench.
Important!
Ensure that drain connection
will comply with Iocal piumbin9
regulations.
FINAL CHECKLIST
[]
[]
Check all parts are installed.
o Excessive water remaining
Ensure product is level, securely fastened to the cabinetry and opens and
[]
properly installed or drain hose not routed correctly.
fauW in the User guide for how to recognise this fault on mode_s without
Ensure inlet hose to water supply has supplied rubber washer fitted, and that
a further half turn after seal contact.
Ensure any knockouts or plugs in drain connection
drain connection
[]
have been drilled out and
o The dishwasher
has been made.
o No program
[]
Turn on the power and water supplies, then open the drawers. You should hear
a beep and see a program indicator light up on the internal control panel.
[]
option called 'Open drawer auto power-on' may need to be turned on.
,
Ensure any packaging or tape securing the racks is removed from the drawers.
lights up when the drawer is opened
lights up, see the 'Preference options' section of the 'Quick start guide: An
the drain hose to the sink trap, ensure the Highloop is a minimum
[]
indicator
Ensure power is connected and is switched on. If it is and still no indicator
length of drain hose should be kept on the dishwasher side of the highloop.
6" (150 mm) higher than the drain hose joiner.
is beeping continuously
There is a fault. See section 'If there is a fault' in the User guide for further
information and instructions.
The drain hose joiner must not support the weight of excess hose material.
If connecting
a
Check water is connected and turned on.
Keep drain hose as fully extended as possible to prevent sagging. Any excess
[]
highloop not
o No water supply (This is displayed as a 'U 1' fault - see section 'If there is a
cabinetry.
it's tightened
above the filter plate, after the rinse cycle
Check for a kinked drain hose or blocked waste connection,
closes freely. The drawers must be free to fully close with no resistance from the
[]
21
TROUBLESHOOTING
Water around water supply and drainage connections
Check connections, existing plumbing
and hoses for leaks. Check rubber
washer and hose clamp are correctly fitted.
,
If product
is tipping
Ensure the product is secured to the cabinetry.
Check the spray arms are in place and free to rotate.
o If front pane_sare misaHgned
Check and relevel product. Check the cabinetry is square. For Integrated
' arm
models, check and adjust front panel alignment
if necessary.
o Drawer doesn't dose property
Ensure nothing is obstructing the drawer from closing properly eg sound
insulation, hoses or drawer latches.
[]
Add three cups of water into each drawer. Press O on the internal control panel
o If a problem occurs, consult the 'Troubleshooting'
until the indicator of the 'Rinse' program lights up. Close the drawers and press
,
Service Center, or contact us through our website, listed below.
After the Rinse program has finished, ensure the dishwasher has run and
Important!
drained correctly.
[]
Check water supply and drainage connection
If after checking these points you still need assistance, please refer to the
Service & Warranty book for warranty details and your nearest Authorized
H_ to start the program.
[]
section of the User guide.
SAVE THESE INSTRUCTIONS
Themodelsshownin this documentmay not be availablein all marketsand aresubjectto change
at anytime.Forcurrentdetailsabout modeland specification availability in your country, please
visitour websitelistedat theend of this documentor con:at:your localFisher& Paykel dealer.
for leakage.
wwwofisherpaykeLcom
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 20 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Sat Sep 12 07:04:43 2015 Author : Title : Subject :EXIF Metadata provided by EXIF.tools