Solenoid Pilot Actuated Valves
503 Series | Zoned Safety Manifold

www.asco.com

Numatics, Inc. is a leading manufacturer of pneumatic products and motion control
products. Our broad spectrum of standard, custom developed products and application components,
have made a significant impact on pneumatic innovation as well as pneumatic and motion control

technology. Our company has an extensive history of generating innovative concepts and technological
breakthroughs. Many of today’s standard features in pneumatic technology were industry firsts from
Numatics. We continue our innovative approach to product development by developing electric motion
control solutions and enhancing our embedded Fieldbus and I/O products to continually meet and solve
our customer’s application requirements.

Today Numatics is proud to be
a part of Emerson Electric Co.
Emerson (NYSE:EMR), based
in St. Louis, Missouri (USA),
is a global leader in bringing
technology and engineering
together to provide innovative
solutions for customers in
industrial, commercial, and
consumer markets through
its network power, process
management, industrial
automation, climate technologies,
and appliance and tools
businesses. For more information,
visit www.Emerson.com.

SERIES

SAFETY OF
MACHINERY

503

Principle of the Safety of Machinery:

To guarantee the safety and health of persons exposed to the installation, operation, adjustment and maintenance
of machinery.

Three key concepts for the design of machinery and their safety functions have emerged from the
implementation of the new Machinery Directive 2006/42/EC:
• A risk analysis prior to design
• A particular consideration of the quantitative aspect of the safety functions in addition to the qualitative
approach
• The use of performance levels (PL)

Risk Evaluation:

The manufacturer or supplier of a machine must see to it that a risk evaluation is conducted to determine the health
and safety requirements for persons involved in its operation. The machine must then be designed and constructed in
accordance with the results of the risk evaluation.
ii

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

RISK EVALUATION

503

“Good engineering practice + probabilistic calculations”

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

iii

SERIES

503

DESIGN PROCESS

EN/IEC 62061 - EN ISO 13849-1

RELIABILITY DATA
for components from manufacturers,
standards, databases etc.
MTTFd: Mean time to dangerous failure–
Value expressed in years
MTTFd
Rating for each channel
Low

3 years < MTTFd < 10 years

Medium

10 years < MTTFd < 30 years

High

30 years < MTTFd < 100 years

B10d: Number of cycles after which 10% of a random sample of wearing components fail dangerously –
Value expressed in number of cycles.
DC:

CCF:

Diagnostic Coverage

DIAGNOSTIC COVERAGE
None

Low

Medium

High

DC < 60%

60% < DC < 90%

90% < DC < 99%

99% < DC

Common Cause Failure. Measures to be taken to prevent a given cause (and its effect) from concurrently
disabling the multiple channels of a safety circuit.

Mission time T10: In line with “good engineering practice” as recommended in EN ISO 13849-1, components
attaining this value must be replaced (precautionary principle).
iv

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

503

FOR YOUR SAFETY

Only the pneumatic part is described in the form of a subsystem in these examples. Other safety-related components
(e.g. protective devices, electrical logic elements) must be added to ensure the safety function is complete.
The examples shown here only relate to the stopping of hazardous movements. In pneumatics, safety measures
concerning the interruption of energy sources, the evacuation of potential energy (pressure contained in a part of
the circuit), and a “progressive” start-up after an unexpected shutdown should not be omitted.

To attain a PL = c, category 1 architecture
• Safety function: Stopping of the potentially hazardous movement of cylinder 1A.
• Functional description:
Dangerous
movement

1A

Input ‘I’: not represented, movable guard or light barrier, etc.
Logic element ‘L’: not represented, PLC

Solenoid valve
selected to ensure
safety compliance

1V 1A

Other consumers
and control systems
0S1 P

• Calculation of the probability of dangerous failure:
Safety
function

1 cycle = 5 s

Working
hours / day
16 h

Working
days / year
240 days

0V 1A

Cycles / year
2,764,800 cycles

B10d (1V1A – series 520) = 130,000,000 cycles, i.e. an operating time of 47 years, MTTFd =470 years “high”
PL
a

PL Performance Levels

b
c

MTTFd rating for each channel = low

d

MTTFd rating for each channel = medium

e

MTTFd rating for each channel = high
Category B
DCavg none

Category 1
DCavg none

Category 2
DCavg low

Category 2
DCavg medium

Category 3
DCavg low

Category 3
DCavg medium

Category 4
DCavg high

By limiting the valve’s operating time to 47 years, this corresponds to a PL = c

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

v

SERIES

503

FUNCTIONS

To attain a PL = c, category 2 architecture
• Safety function: Stopping of the potentially hazardous movement of cylinder 1A.
• Functional description:
Category 2:

1S1

Diagnostics

Output
Signal

TE

1V 1B
a

Output
Signal

Dangerous
movement

O

Diagnostics

L

G

1A

Diagnostics

I

Input
Signal

Diagnostics

b

Other consumers
and control systems

OTE

0S1 P

TE : Test equipment
OTE : Output of test equipment

0V 1B

Input ‘I’: not represented, movable guard or light barrier, etc.
Logic element ‘L’: not represented, PLC
Stop of cylinder ensured by:

Diagnostics ensured by:

Output O: Valve 1V1B

Cross-monitoring in L1 of the supply status coherence of coils 1V1Ba and 1V1Bb
and the limit switches 1S1

0V1: Energy isolating valve: ensures the system is exhausted in case of loop failure.
• Calculation of the probability of dangerous failure:
Safety
function

Working
hours / day

Working
days / year

Cycles / year

1 cycle = 5 s

16 h

240 days

2,764,800 cycles

B10d (valve 1V1B - series 542) = 44,912,670 cycles, i.e. an operating time of 16.2 ans,
MTTFd = 162 years “high”
MTTFd (sensors 1S1) = 45,000,000h, i.e. 11,718 years “high”
The case study shows: DC (Diagnostic Coverage) = 60% “low”
PL
a

PL Performance Levels

b
c

MTTFd rating for each channel = low

d

MTTFd rating for each channel = medium

e

MTTFd rating for each channel = high
Category B
DCavg none

Category 1
DCavg none

Category 2
DCavg low

Category 2
DCavg medium

Category 3
DCavg low

Category 3
DCavg medium

Category 4
DCavg high

By limiting the valve’s operating time to 16.2 years, this corresponds to a PL = c for the safety loop.
vi

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

503

FOR YOUR SAFETY
To attain a PL = d, category 3 architecture
• Safety function: Stopping of the potentially hazardous movement of cylinder 1A.
• Functional description:
G

Categories 3 and 4:
Input
Signal

L1

Cross-checking
diagnostics

I1

I2

1A

Diagnostics

Output
Signal

Dangerous
movement

2Z1

O1

S21 P
1V 1B
a

Diagnostics

L2

Input
Signal

Output
Signal

1S1

b

O2

Other consumers
and control systems

0S1 P
0V 1B

Inputs ‘I1’ and ‘I2’: not represented, movable guard
or light barrier, etc.
Logic elements ‘L1’ and ‘L2’: not represented, PLC
Stop of cylinder ensured by:

2V1

Output O: Valve 1V1B

Cross-monitoring in L1 of the supply status coherence of coils
1V1Ba and 1V1Bb and the limit switches 1S1

Output O2: Valve 2V1 controlling the
rod lock 2Z1

Pressure switch 2S1 for transmission of signal to L2

Cross-monitoring of L1/L2 status
coherence within the PLC

0V1B: Energy isolating valve: ensures the system is exhausted.
• Calculation of the probability of dangerous failure:
Safety
function

1 cycle = 10 s

Working
hours / day
16 h

Working
days / year
240 days

Cycles / year
1,382,400 cycles

B10d (valve 1V1B - series 542) = 44,912,670 cycles, i.e. an operating time of 32.4 years, MTTFd = 324 years “high”
B10d (valve 2V1 - series 520) = 20,000,000 cycles, i.e. an operating time of 14.5 years, MTTFd = 145 years “high”
B10d (pressure switch 2S1, dynamic rod lock 2Z1) = 4,000,000 cycles, i.e. a mission time of T10 = 2.89 years,
MTTFd = 28.9 years “medium”
MTTFd (sensors 1S1) = 45,000,000 h, i.e. 11,718 years “high”
The case study shows: DC (Diagnostic Coverage) = 60% “low”, DC (2V1) = 99% “high”, DC* (2Z1) = 75%
i.e. for channel O2, DC = 78% “low”

* “Good engineering practice” methods associate this type of component
with a low-to-medium DC to cover any of the component’s drift failures.

PL
a

PL Performance Levels

b

MTTFd rating for each channel = low

c
d

MTTFd rating for each channel = medium

e

MTTFd rating for each channel = high
Category B
DCavg none

Category 1
DCavg none

Category 2
DCavg low

Category 2
DCavg medium

Category 3
DCavg low

Category 3
DCavg medium

Category 4
DCavg high

By limiting the operating time of the pressure switch and rod lock to 2.89 years, this corresponds to
a PL = d for the safety loop.
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

vii

SERIES

503

FUNCTIONS

To attain a PL = d, category 3 architecture
• Safety function: Stopping of the potentially hazardous movement of cylinder 1A.
• Functional description:
Category 2:

1S1

Diagnostics

TE

1V 1B
a

Output
Signal

Dangerous
movement

O

Diagnostics

L

Output
Signal

G

1A

Diagnostics

I

Input
Signal

Diagnostics

b

Other consumers
and control systems

OTE

0S1 P

TE : Test equipment
OTE : Output of test equipment

0V 1B

Inputs ‘I1’ and ‘I2’: not represented, movable guard or light barrier, etc.
Logic elements ‘L1’ and ‘L2’: not represented, PLC
Stop of cylinder ensured by:
Output O: Valve 1V1B

Comparison in L1 of the supply status of coils 1V1Ba
and 1V1Bb and the limit switches 1S1

Output O2: Valve 2V1 controlling the two 2/2
"cylinder stop" valves used as braking units

Pressure switch 2S1 for transmission of signal to L2

Cross-monitoring of L1/L2 status
coherence within the PLC

0V1B: Energy isolating valve: ensures the system is exhausted.
• Calculation of the probability of dangerous failure:
Safety
function

1 cycle = 10 s

Working
hours / day
16 h

Working
days / year
240 days

Cycles / year
1,382,400 cycles

B10d (valve 1V1B - series 542) = 44,912,670 cycles, i.e. an operating time of 32.4 years, MTTFd = 324 years “high”
B10d (valve 2V1 - series 520) = 20,000,000 cycles, i.e. an operating time of 14.5 years, MTTFd = 145 years “high”
B10d (pressure switch 2S1, dynamic rod lock 2Z1) = 4,000,000 cycles, i.e. a mission time of T10 = 2.89 years,
MTTFd = 28.9 years “medium”
B10d (2/2 cylinder stop valves 2V3, 2V2) = 60,000,000 cycles, i.e. MTTFd = 434 years “high”
The case study shows: DC (1V1B)=60% “low”, DC (2V1)=99% “high”, DC* (2V3, 2V2)=60%, i.e. for channel O2,
DC = 78% “low”.
* “Good engineering practice” methods associate this type of component
with a low-to-medium DC to cover any of the component’s drift failures.

PL
a

PL Performance Levels

b

MTTFd rating for each channel = low

c
d

MTTFd rating for each channel = medium

e

MTTFd rating for each channel = high
Category B
DCavg none

viii

Category 1
DCavg none

Category 2
DCavg low

Category 2
DCavg medium

Category 3
DCavg low

Category 3
DCavg medium

Category 4
DCavg high

By limiting the operating time of the pressure switch and rod lock to 2.89 years, this corresponds to
a PL = d for the safety loop.
Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

Table of Contents
503 Series

Technical and Operating Data
How to Order
Sandwich Pressure Regulators
Valve Regulator/Speed Control Plug-in Assembly
Regulator Service Kits and Parts
Sandwich Pressure Regulator Dimensions
Manifold Assembly
Valve on Manifold Block
Sandwich Port 4 Supply Block
Sandwich Pilot Supply Block
Sandwich Pressure Block
Sandwich Exhaust Block
Blank Station Plate Kit
Speed Control Kit
DIN Rail Clamp Kit
Blocking Discs
End Plate Kits
Manifold Assembly Dimensions
Internal/External Pilot Selection
Internal Muffler

G3 Electronics

Features and Benefits
Ethernet
PROFINET®
Ethernet POWERLINK®
EtherCAT®
EtherNet/IP™ DLR
CC-Link IE Field™
I/O Modules
Miscellaneous Modules & Accessories
G3 Fieldbus Communication Assembly Dimensions
How to Order G3 Assembly Kit & G3 Electronics
How to Order Complete G3 Manifold Assemblies
Cables & Connectors
PROFINET® Cables & Connectors
Ethernet POWERLINK® Cables & Connectors
EtherCAT® Cables & Connectors
Ethernet Cables & Connectors
I/O Cables & Connectors

2
3
4
5
5
6
7
7
11
12
13
13
14
14
15
15
15
16
17
17
19
21
22
23
24
25
26
27
30
32
33
34
35
38
39
40
41
42

SERIES

503

503 SERIES

5 Ported, 2 and 3 position, 4-way, Spool & Sleeve and Rubber
Seal, Cv: 1.2 - 1.4
• Solenoid air pilot actuated
• Low wattage – 1.7 watt for DC application
• DC solenoids polarity insensitive with surge suppression
Plug together circuit boards eliminate internal wiring
• Integral recessed gaskets
• IN Fittings to accommodate various tube sizes
• Simple conversion from internal to external pilot
• G3 Fieldbus electronics
• IP65 Certified

Performance Data

Valve Data

Pilot Pressure Range
Valve Operating Pressure Range
Ambient Temperature Range

Min.

29 PSI (2 Bar)

Max.

115 PSI (8 Bar)

-10 °C (-14 °F)

50 °C (122 °F)

Proprietary

Valve Flow Data

Cv

NL/m
(6 - 5 Bar)

Cv

NL/m
(6 - 5 Bar)

5/2, Double Solenoid & Single Solenoid,
Spring Return (Spool & Sleeve)

1.1

1100

1.2

1200

5/2, Double Solenoid & Single Solenoid,
Spring Return (Rubber Seal)

1.2

1200

1.4

1400

2X 3/2 NC-NC

0.9

900

1.0

1000

2X 3/2 NO-NO

0.9

900

1.0

1000

Double Solenoid, 3 pos. 4 way, Spring
Centered- Open to 4 and 2 in center

0.6

600

0.6

600

Double Solenoid, 3 pos. 4 way, Spring
Centered - Open Center

1.1

1100

1.3

1300

Double Solenoid, 3 pos. 4 way, Spring
Centered - Closed Center

1.2

1200

1.4

1400

Operating Data

All Solenoids Are Continuous Duty Rated
Power (Watts)

double solenoid air pilot
2 position 4-way
(Spool & Sleeve)
double solenoid air pilot
3 position 4-way
open center
double solenoid air pilot
3 position 4-way
closed center
double solenoid air pilot
3 position 4-way
pressure center

14

2 4

12

315

115 PSI (8 Bar)

28" HG Vacuum

ISO

14

2 4

12

315
12

2 4

Response Time (ms)

12

5/2, Single Solenoid, Spring Return

315
14

4

60

5/2, Double Solenoid

15

5/3 Spring Centered

–

2x3/2 NC
2 X3/2 NO

12

2

3 15

double solenoid
2 position dual 3-way
“14” & “12” NO

12

double solenoid
2 position dual 3-way
“14” & “12” NC

12

2

3

4

1

2

3

0.071

20

14

24

24 VDC

Spool & Sleeve
Energize
Deenergize

14

315

1.7

Holding Current (Amps)

2

single solenoid air pilot
2 position 4-way

Rubber Seal
Energize
Deenergize
20

60

N/A

20

N/A

–

15

20

–

–

15

25

–

–

15

20

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

5
4

1

14

5

14

SERIES

503
How to Order
Valve

R

503

A

2

B

4

0

M

A00

F1

Product Series
503 = 26mm Valve

Voltage
F1 = 24 DC

Revision
A
= Initial Release

Options
A00 = Standard (No Options)
11B = Flush Locking Manual
Override
11M = Without Manual Override
11Z = With push-button type
maintained manual operator

Valve Type
1
= Spool and Sleeve*
2
= Rubber Packed
Actuation
B
= Solenoid Pilot with Flush Non-Locking Override
Function
1
= 2 Position 4-Way (5/2), Spring Return
4
= 2 Position 4-Way (5/2), Dual Solenoid
5
= 3 Position 4-Way (5/3), Open Center, Dual Pressure
6
= 3 Position 4-Way (5/3), Blocked Center
7
= 3 Position 4-way (5/3), Open to A & B in Center
A
= Dual 3-way, A normally open - B normally open
D
= Dual 3-way, A normally closed - B normally closed
N
= Differential Air Return w/o Spring

Electrical
M = Plug-in, w/ Light, VDC
N
= M12 Connector Pin#1 =
unused, #2 = Coil 12, #3 =
Common, #4 = Coil 14
Port Size
0
= No Port Size

* Spool and Sleeve not available with Functions 6, A, D, and N

Regulator

R 503 A R S 1 1 J A00 1 0

Product Series
503 = 26mm Valve
Revision
A
= Initial Release
Product Type
R
= Regulator
Regulator Type
S
= Single Reg. - Pressure to Port 1
D
= Double Reg. - Pressure to Ports 5 & 3
E
= Double Reg. - Pressure to Ports 4 & 2, w/o Valve*
T
= Double Reg. - Pressure to Ports 1 & 3, 2
Pressure Selector
Pressure Range
1
= 10 - 130 PSIG (0.7 - 9 bar)
3
= 3 - 30 PSIG (0.2 - 2 bar)
4
= 5 - 60 PSIG (0.3 - 4.1 bar)
* For Regulator Type "E" must select "0" wiring option + "0" interface

Reserved
Interface
1
= Proprietary
2
= ISO 15407-2
0
= No Interface*
Options
A00 = Standard (No Options)
16N = Jumper for Supply Pressure
to Valve, 14 End
16P = Jumper for Supply Pressure
to Valve, 12 End
Wiring Options
J
= Plug-in, Receptacle Assembly
0
= Non Plug-in*
Gauge Type
1
= PSI
2
= bar

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

3

SERIES

SANDWICH PRESSURE
REGULATORS

503

Sandwich Pressure Regulators
Types: RS / RD / RE / RT

ISO 15407-2 Interface

Proprietary Interface

External Outlet Regulator

Type RS							Type RD
1

3

5

2 4

24
1
SUPPLY

3

Single pressure from a single supply.

1
SUPPLY

5
1

Dual pressure from a single supply.

31

5

Type RE							Type RT
1

5

4

2

4 2

3

1
SUPPLY

External outlet regulator used with jumper plate
for single or dual pressure.

4

3

1
SUPPLY

Two-pressure selector used for multi-pressure
applications.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

5

3
1

VALVE REGULATOR/
SPEED CONTROL
PLUG-IN ASSEMBLY

SERIES

503

Valve Regulator / Speed Control Plug-in Assembly

R503A2B10MA00F1

VALVE

REGULATOR

SPEED CONTROL

MOUNTING

Regulator Kits and Service Parts
Regulator Service Kit

R503ARS11JA0010

R503AS425575002

8503AMM22MA0010

Regulator Unit Kits

(includes regulator assembly, gaskets, screws)
Part Number

Description

M503AR428759001

3-30 PSIG Regulator Kit

M503AR428759002

5-60 PSIG Regulator Kit

M503AR428759003

10-130 PSIG Regulator Kit

M503AR428759004

0.2-2.0 Bar Regulator Kit

M503AR428759005

0.3-4.0 Bar Regulator Kit

M503AR428759006

0.7-9.0 Bar Regulator Kit

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

5

SERIES

503
Dimensions: mm (inches)

Dimensional Drawing - Sandwich Pressure Regulator
Single Regulator

C

D

F

B

E

A

A

B

C

D

E

F

202.7
(7.98)

144.1
(5.673)

78.2
(3.08)

34.8
(1.37)

26
(1.02)

13
(0.51)

Double Regulator

C

D

B

F
E

A

6

A

B

C

D

E

F

268.2
(10.56)

144.1
(5.673)

78.2
(3.08)

34.8
(1.37)

26
(1.02)

13
(0.51)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

MANIFOLD
ASSEMBLY

503

How to Order
Manifolds

8 503 A M S2 2 M A00 1 0

Port Type
8
G

=
=
=

K

Interface

NPTF1
ISO228/1-G1
Push-in Fittings

1
2

=

A00 =
83H =

26mm Valve

Revision
A

=

=
=

Manifold Subbase
Mid-Station Supply2

Mounting
S2

=

M2

=

1
2
3
4
5

Standard (No Options)
Pilot Separation for Station 13

Wiring Options

Initial Release

Product Type
M
Z

Proprietary
ISO15407-2

Options

Product Series
503

=
=

Manifold Subbase, 2 Stations, Side Ports,
Single Z-Board
Manifold Subbase, 2 Stations, Side Ports,
Double Z-Board

M
0
U

=
=
=

X

=

Plug-in, Receptacle Assembly
Non-Plug-in
M12 Connectors w/Pass Thru
Communication Pin 1 = Coil 14,
Pin 2 = Not Used, Pin 3 = Common,
Pin 4 = Not Used4
0 & 24 VDC Separation at First Station
of a Safety Zone5

Port Size
2
3
H
K

Port Type '8' and 'G' only available with Port Size '2'
Only available with 'M' Wiring and 'M2' Mounting
Only available with 'X' Wiring
Only available with Product Type 'M' and 'S2' Mounting
Only available with Product Type 'M' and 'M2' Mounting

=
=
=
=

1/4
3/8
8mm
10mm

Dimensions: mm (inches)

Dimensional Drawing - Plug-in Valve Mounted

G

A

B
C
F

H

E
D

A

B

C

D

E

F

G

H

112.9
(4.445)

44.9
(1.768)

14.2
(0.56)

54
(2.13)

43.7
(1.72)

16.7
(0.66)

53.3
(2.098)

136
(5.35)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

7

SERIES

503
Dimensions: mm (inches)

Dimensional Drawing - M12 Valve Mounted

J

A

B
C
F

H

E
D

8

A

B

C

D

E

F

H

J

129.4
(5.094)

44.9
(1.768)

14.2
(0.56)

54
(2.13)

43.7
(1.72)

16.7
(0.66)

136
(5.35)

61
(2.4)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

503
Dimensions: mm (inches)

Dimensional Drawing - Plug-in Valve Mounted (X Wiring Option)

A

B

C

D

E

F

G

H

J

K

112.9
(4.445)

44.85
(1.766)

14.15
(0.557)

54
(2.126)

43.65
(1.719)

16.65
(0.656)

148.654
(5.853)

136
(5.354)

42.5
(1.673)

40.5
(1.594)

Zoned Power Manifold Base (“X” Wiring”)

• Via M12 Connector supplies power to up to 16 valve solenoid coils
• All valve solenoid coils are controlled via the attached G3 node
• When M12 connector is externally supplied by a Safety Relay or Safety Output via a Safety PLC the
valves within the Safety zone become one of the redundant channels of a Category 3 or 4 circuit

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

9

SERIES

503
Dimensions: mm (inches)

Dimensional Drawing - Plug-in Valve Mounted (U Wiring Option)

A

B

C

D

E

F

G

H

J

K

L

112.9
(4.445)

44.85
(1.766)

14.15
(0.557)

54
(2.126)

43.65
(1.719)

16.65
(0.656)

148.654
(5.853)

136
(5.354)

42.5
(1.673)

40.5
(1.594)

13.5
(0.531)

Pilot Valve Manifold Base (“U” Wiring)

• Allows mounted pilot valves to be electrically controlled via M12 connector; isolated from the connected
G3 node
• When M12 connector is externally supplied by a Safety Relay or Safety Output via a Safety PLC the pilot
valves become one of the redundant channels of a Category 3 or 4 circuit
• Pilot supply valves when used to supply Pilot Operated Check Valves, Rod-Locks, Pilot Operated Spring
Return Valves etc provide one of the channels required for Category 3 & 4 circuits

10

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

SANDWICH PORT 4
SUPPLY BLOCK

503

• Monitors pressure to external devices by
DPS280 Pressure Switch
• Can be use to supply pressure from Port 4 of
valve to pilot Safety zone of manifold via Pilot
Separation Pilot block
• Vertical and Horizontal orientation of DPS 280
allows for mounting on adjacent stations

Vertical

Horizontal

Part Number

Port for Pilot Supply

Description

8503AU516663005

Plugged

Proprietary Port 4 supply block with Vertical DPS280

8503AU516663009

Plugged

Proprietary Port 4 supply block with Horizontal DPS280

K503AU516663006

5/32 (4mm) Push-In Fitting

Proprietary Port 4 supply block with Vertical DPS280

K503AU516663010

5/32 (4mm) Push-In Fitting

Proprietary Port 4 supply block with Horizontal DPS280

8503AU516663003

Plugged

ISO15407-2 Port 4 supply block with Vertical DPS280

8503AU516663007

Plugged

ISO15407-2 Port 4 supply block with Horizontal DPS280

K503AU516663004

5/32 (4mm) Push-In Fitting

ISO15407-2 Port 4 supply block with Vertical DPS280

K503AU516663008

5/32 (4mm) Push-In Fitting

ISO15407-2 Port 4 supply block with Horizontal DPS280

A

B

C

D

E

F

G

H

J

w/Vertical DPS280

212.48
(8.365)

197.21
(7.764)

148.78
(5.857)

58.58
(2.306)

83.55
(3.289)

33
(1.299)

17
(0.669)

30
(1.181)

26.5
(1.043)

w/Horizontal DPS280

236.02
(9.292)

148.78
(5.857)

58.58
(2.306)

169.98
(6.692)

5951
(2.343)

44.23
(1.741)

33
(1.299)

30
(1.184)

26.5
(1.043)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

11

SERIES

SANDWICH PILOT
SUPPLY BLOCK

503

• Allows for introduction of secondary pilot supply to either an
individual valve or zone of valves on manifold. Supply to zone of
manifold requires selection of Manifold Block and End Plates with
Pilot Separation option
• Pilot Supply air can be from either an external valve or integrated
into the manifold via the Port 4 Supply Block

12

Part Number

Port for Pilot Supply

Description

8503AP428300008

1/4 NPTF

Proprietary Zoned Pilot Supply Block

G503AP428300008

G 1/4

Proprietary Zoned Pilot Supply Block

K503AP428300010

5/32 (4mm) Push-In Fitting

Proprietary Zoned Pilot Supply Block

8503AP428300007

1/4 NPTF

ISO15407-2 Zoned Pilot Supply Block

G503AP428300007

G 1/4

ISO15407-2 Zoned Pilot Supply Block

K503AP428300009

5/32 (4mm) Push-In Fitting

ISO15407-2 Zoned Pilot Supply Block

8503AP428300006

1/4 NPTF

Proprietary Independent Pilot Supply Block

G503AP428300006

G 1/4

Proprietary Independent Pilot Supply Block

8503AP428300005

1/4 NPTF

ISO15407-2 Independent Pilot Supply Block

G503AP428300005

G 1/4

ISO15407-2 Independent Pilot Supply Block

A

B

C

D

E

F

161
(6.350)

148.78
(5.857)

58.58
(2.306)

33
(1.299)

17
(0.669)

26.5
(1.043)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

503
Dimensions: mm (inches)

Dimensional Drawing - Sandwich Pressure Block
• Used to supply a separate pressure to a single
valve station without needing blocking disks

1

A
D

C

B

Sandwich Pressure Block Kit
Part Number

Port Type

Description

8503AW428300004

1/4 NPTF

Proprietary Sandwich Pressure Block

G503AW428300004

G 1/4

Proprietary Sandwich Pressure Block

8503AW428300003

1/4 NPTF

ISO 15407-2 Sandwich Pressure Block

G503AW428300003

G 1/4

ISO 15407-2 Sandwich Pressure Block

A

B

C

D

148.8
(5.858)

58.6
(2.307)

33
(1.3)

26.5
(1.04)

Sandwich Exhaust Block
3

• Used to isolate the exhaust of a single valve
station from the manifold

5

• Allows faster exhaust response by re-routing
exhaust externally to the manifold

A
D

C

B

Sandwich Exhaust Block Kit
Part Number

Port Type

Description

8503AX428300002

1/4 NPTF

Proprietary Sandwich Exhaust Block

G503AX428300002

G 1/4

Proprietary Sandwich Exhaust Block

8503AX428300001

1/4 NPTF

ISO 15407-2 Sandwich Exhaust Block

G503AX428300001

G 1/4

ISO 15407-2 Sandwich Exhaust Block

A

B

C

D

159.2
(6.268)

70.2
(2.764)

33
(1.3)

26.5
(1.04)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

13

SERIES

503
Dimensions: mm (inches)

Dimensional Drawing - Blank Station Plate Kit
P503AB428359001

A

• Used to block off a manifold station block for
future use
B

C

A

B

C

136
(5.354)

26
(1.024)

14.8
(0.58)

Speed Control Kit

A
B

D

C

14

Part Number

Description

R503AS425575002

Proprietary Sandwich Speed Control

R503AS425575001

ISO 15407-2 Sandwich Speed Control

A

B

C

D

142
(5.591)

58
(2.283)

33
(1.3)

26
(1.02)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

503
DIN Rail Clamp Kit

Blocking Disc Kits

239-980

(Includes tag to label ports blocked)
Ports

Part

1

P503AD431191001

3

P503AD431191002

5

P503AD431191003

1+3

P503AD431191004

1+5

P503AD431191005

3+5

P503AD431191006

1, 3, 5

P503AD431191007

Zoned Safety End Plate Kit - Threaded

PORT TYPE

NPTF

G

PUSH-IN

PUSH-IN

PUSH-IN

PUSH-IN

Port Type

1

3/5

12/14

1

3/5

12/14

1

3/5

12/14

1

3/5

12/14

1

3/5

12/14

1

3/5

12/14

Port Size

3/8

3/8

1/8

3/8

3/8

1/8

3/8

3/8

1/8

1/2

1/2

1/8

10mm

10mm

6mm

12mm

12mm

6mm

Vertical w/o muffler,
w/o DIN

8503AK428327001

G503AK428327013

K503AK428327003

K503AK428327005

K503AK428327015

K503AK428327017

Vertical w/o muffler,
w/DIN

8503AK428327002

G503AK428327014

K503AK428327004

K503AK428327006

K503AK428327016

K503AK428327018

Vertical w/muffler,
w/o DIN

8503AK428327007

G503AK428327019

K503AK428327009

K503AK428327011

K503AK428327021

K503AK428327023

Verical w/muffler,
w/DIN

8503AK428327008

G503AK428327020

K503AK428327010

K503AK428327012

K503AK428327022

K503AK428327024

Vertical w/o muffler,
w/o DIN, w/Pilot
Separation

8503AK428327025

G503AK428327037

K503AK428327027

K503AK428327029

K503AK428327039

K503AK428327041

Vertical w/o muffler,
w/DIN, w/Pilot
Separation

8503AK428327026

G503AK428327038

K503AK428327028

K503AK428327030

K503AK428327040

K503AK428327042

Vertical w/muffler,
w/o DIN, w/Pilot
Separation

8503AK428327031

G503AK428327043

K503AK428327033

K503AK428327035

K503AK428327045

K503AK428327047

Verical w/muffler,
w/DIN, w/Pilot
Separation

8503AK428327032

G503AK428327044

K503AK428327034

K503AK428327036

K503AK428327046

K503AK428327048

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

15

SERIES

503
Dimensions: mm (inches)

Dimensional Drawing - Manifold Assembly
C
D
6.3 Wide Slot
(2) Places

E

A

F

B

Ø6.4

J

K

L

G
M
N
Q
H

U

R

S

T

P

V
W

A Ref.

X
Y

16

A

B

C

D

E

F

G

H

J

K

L

M

136
(5.354)

53
(2.087)

55.1
(2.17)

7.5
(0.3)

75.8
(2.98)

39.1
(1.54)

112.9
(4.445)

12
(0.47)

54
(2.13)

17.5
(0.69)

19.8
(0.78)

101.1
(3.98)

N

P

Q

R

S

T

U

V

W

X

Y

69.5
(2.74)

46.8
(1.843)

44.9
(1.77)

24.4
(0.96)

14.2
(0.56)

12.3
(0.48)

6.4
(0.25)

23.8
(0.94)

58
(2.28)

85
(3.346)

125.4
(4.937)

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

503
Internal Pilot

External Pilot
Internal Pilot
Supply Plug Location

For External Pilot
Supply Plug Location

• Pilot selection can only be made at the left hand end plate when the manifold has pilot separation

Internal Muffler
Muffler

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

17

Fieldbus Electronics

G3 | Communication Node and I/O

Table of Contents
Section 1

Features and Benefits
Ethernet
PROFINET®
Ethernet POWERLINK®
EtherCAT®
EtherNet/IP™ DLR
CC-Link IE Field™
I/O Modules
Miscellaneous Modules & Accessories
G3 Fieldbus Communication Assembly Dimensions

Section 2 - How to Configure & Order G3 Electronics
How to Order G3 Assembly Kit & G3 Electronics
How to Order Complete G3 Manifold Assemblies
Cables & Connectors
PROFINET® Cables & Connectors
Ethernet POWERLINK® Cables & Connectors
EtherCAT® Cables & Connectors
Ethernet Cables & Connectors
I/O Cables & Connectors

19
21
22
23
24
25
26
27
30
32
33
34
35
38
39
40
41
42

ELECTRONICS

G3 Fieldbus
G3 Fieldbus - Electronics Made Easy!
Innovative Graphic Display is used for easy commissioning, visual
status & diagnostics.

Commissioning Capabilities
• Set network address (including
IP & Subnet mask for Ethernet)

• Shorted and open load
detection

• Set baud rate

• Shorted sensor/cable detection

• Set auto or manual I/O sizes

• Low & missing power detection

• Set fault/idle output states

• Missing module detection

• Set brightness

• Self-test activation

• Set factory defaults

• Log of network errors

• Visual diagnostics

• Distribution errors

Graphic Display for
Configuration & Diagnostics

Auto Recovery Module

Highly Distributable

Easy, Robust Connections

G3 Fieldbus Communications Electronics

Why use Numatics Fieldbus communication electronics?
Modular Reality...
No internal wiring simplifies assembly
• SPEEDCON M12 connector technology allows for fast and
efficient ½ turn I/O connector attachment

Supported Protocols

• Power connector allows output power to be removed while
inputs and communication are left active

• Ethernet

• PROFINET®

• IP65 protection
• Up to 1200 Input/1200 Output capability with one
communication node! (Present physical I/O combinations allows
1200 I/544 O)
• 32 valve solenoids per manifold up to 17 manifolds per
communication node!

• Ethernet POWERLINK®
• EtherCAT®
• EtherNet/IP™ DLR
w/QuickConnect™
• CC-Link IE Field™

• One node supports 16 I/O modules – Analog I/O, Digital I/O
(NPN & PNP) and Specialty
• Innovative clip design allows easy module removal/replacement
without dismantling manifold
• Auto Recovery Module (ARM) protects configuration information
during a critical failure. Allows configuration information to be
saved and reloaded to replacement module automatically

I/O with
*Numatics
SPEEDCON technology
®

*

• 1/2 turn for faster I/O connections
• Backwards compatible with standard
M12 cables/connectors
• Meets the same IP/NEMA standards
as M12/Micro cables/connectors
• Same cost as standard M12/Micro
cables/connectors
• See pages 42 & 43 for cables with
SPEEDCON® connector technology.

PROFINET is a registered trademark of Profibus Nutzerorganisation e.V.
Ethernet POWERLINK is a registered trademark of Bernecker + Rainer Industrie – Elektronik Ges.m.b.H.
CC-Link is a registered trademark and CC-Link IE Field is a trademark of the CC-Link Partner Association.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

19

ELECTRONICS

G3 Fieldbus

G3 Electronics Modularity
Discrete I/O

The G3 Series product line is a completely modular system. All of the G3 electronic modules plug together, via
mechanical clips, allowing easy assembly and field changes. This makes the system highly distributable. Additional
flexibility is incorporated because the same modules can be used in either centralized or distributed applications.
The G3 electronics interfaces with the highly modular Numatics 500 Series, generation 2000 Series, ISO 5599/2
and ISO 15407-2 Series valve lines to further enhance the modularity and flexibility of the entire system.

Sub-Bus Out or
Terminator Module

Jumper Clips

I/O Labels
Auto Recovery Module (ARM)

I/O ModulesAnalog or Digital
NPN or PNP
Communication
Module (Node)
Valve Manifold Assembly
501, 502, 503, 2002, 2005,
2012, 2035, ISO15407-2 &
ISO 5599/2 Series Valves

DIN Rail Mounting Option

20

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

ELECTRONICS

G3 Fieldbus
Ethernet (EtherNet/IP™ & Modbus TCP/IP)
Ethernet used throughout the world to network millions of PCs
has now evolved into a viable industrial network. Ethernet is
an open architecture high-level communication network that
meets the demands of today’s industrial applications requiring
high-speed (10/100 Mbit/s), high-throughput and flexibility.
Additionally, Ethernet technology can integrate an on-board
web server, which can make the node readily accessible to
any standard web browser for configuration, testing and even
retrieval of technical documentation.
Numatics’ G3 nodes for Ethernet have an integrated graphic
display and are capable of addressing combinations of up to
1200 outputs and 1200 inputs.
The G3 EtherNet/IP™ nodes have been tested and approved
for conformance by the ODVA.
More information about EtherNet/IP™ and the ODVA can be
obtained from the following website: www.odva.org.

Technical Data
Electrical Data

Description

Replacement Part
Number

EtherNet/IP™ communications
module (node)

240-181

Modbus TCP/IP communications
module (node)

240-292

Voltage

Current

Node Power at Max. Brightness

24 VDC +/- 10%

.091 Amps

Valves & Discrete I/O

24 VDC +/- 10%

8 Amps maximum

Power Connector

Single key 4 pin 7/8" MINI type (male)

Communication Connector

D-coded 4 pin M12 type (female)

LEDs

Module Status, Network Status and Activity/Link

Temperature Range (ambient)

-23 ºC to 50 ºC (-10 ºF to 115 ºF)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC60068-2-6

Moisture Protection

IP65 (with appropriate assembly and termination)

Graphic Display

Display used for setting IP Address, Subnet mask, Fault/Idle Actions, DHCP/BootP and all other system
settings

ARM

(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event
of total or partial system failure

Maximum Valve-Solenoid Outputs

32

Maximum Addressable I/O Points

Various combinations of 1200 outputs and 1200 inputs

Supported Baud Rates

10 Mbit/100 Mbit

Bus Connector

D-coded 5 pin M12 type (female)

Diagnostics

Power, short, open load conditions and module health are monitored

Special Features

Integrated web server, fail-safe device settings, HTTP, FTP, and UNICAST (for EtherNet/IP™)

Operating Data

Configuration Data

Network Data

Weight
Ethernet Communications Module

255g/9 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

21

ELECTRONICS

G3 Fieldbus

PROFINET®

PROFINET® is the innovative open standard for Industrial
Ethernet, developed by Siemens and the PROFIBUS® User
Organization (PNO). PROFINET® complies to IEC 61158 and IEC
61784 standards. PROFINET® products are certified by the PNO
user organization, guaranteeing worldwide compatibility.
Numatics’ G3 nodes for PROFINET® IO (PROFINET® RT) have
an integrated graphic display and are capable of addressing
combinations of up to 1200 outputs and 1200 inputs.
PROFINET® is based on Ethernet and uses TCP/IP and IT
standards and complements them with specific protocols and
mechanisms to achieve Real Time performance.
More information regarding PROFINET® can be obtained from
the following website: www.profibus.com.

Description

Replacement Part
Number

PROFINET® communications
module (node)

240-240

Technical Data
Electrical Data

Voltage

Node Power at Max. Brightness

24 VDC +/- 10%

Valves & Discrete I/O

24 VDC +/- 10%

Power Connector

Single key 5 pin 7/8” MINI type (male)

Communication Connector

Two D-coded 4 pin M12 type (female)

LEDs

Module Status, Network Status and Activity/Link

Current
8 Amps Maximum

Operating Data
Temperature Range (ambient)

-23 ºC to 50 ºC (-10 ºF to 115 ºF)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC60068-2-6

Moisture Protection

IP65 (with appropriate assembly and termination)

Graphic Display

Display used for setting IP Address, Subnet Mask, Fault/Idle Actions, and all other system settings

ARM

(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
total or partial system failure

Maximum Valve-Solenoid Outputs

32

Maximum Addressable I/O Points

Various combinations of 1200 outputs and 1200 inputs

Supported Baud Rates

10 Mbit/100 Mbit

Bus Connector

Two D-coded 4 pin M12 type (2-Female)

Diagnostics

Power, short, open load conditions and module health and configuration are monitored

Special Features

Integrated web server, Integrated 2 port switch, fail-safe device settings, and FSU

Configuration Data

Network Data

Weight
PROFINET® Communications Module

22

227g/8 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

ELECTRONICS

G3 Fieldbus
Ethernet POWERLINK®

®

Ethernet POWERLINK® is an open fieldbus
protocol designed by B&R for communication
between automation control systems and distributed I/O at the
device level.
Numatics' G3 Ethernet POWERLINK® nodes have an integrated
graphic display and are capable of addressing combinations of
up to 1200 outputs and 1200 inputs.
The G3 Ethernet POWERLINK® nodes have been designed and
tested to conform to the Ethernet POWERLINK® specifications
available at EPSG group (Ethernet Powerlink® Standardization
Group). The certification process ensures interoperability for all
Ethernet POWERLINK® devices and compatible with B&R systems.
More information regarding Ethernet POWERLINK® can be
obtained from the following website:
www.ethernet-powerlink.org.

Technical Data
Electrical Data

Description

Replacement Part
Number

POWERLINK
POWERLINK®®communications
communications
module (node)
module (node)

240-309

Voltage

Node Power at Max. Brightness

24 VDC +/- 10%

Valves & Discrete I/O

24 VDC +/- 10%

Power Connector

Single key 5 pin 7/8” MINI type (male)

Communication Connector

Two D-coded 4 pin M12 type (female)

LEDs

Module Status, Network Status and Activity/Link

Current
8 Amps maximum

Operating Data
Temperature Range (ambient)

-23 ºC to 50 ºC (10 ºF to 115 ºF)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC60068-2-6

Moisture Protection

IP65 (with appropriate assembly and termination)

Configuration Data
Graphic Display

Display used for setting IP Address, Subnet Mask, Fault/Idle Actions, and all other system settings

ARM

(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
total or partial system failure

Maximum Valve-Solenoid Outputs

32

Maximum Addressable I/O Points

Various combinations of 1200 outputs and 1200 inputs

Network Data
Supported Baud Rates

10 Mbit/100 Mbit

Bus Connector

Two D-coded 4 pin M12 type (2-Female)

Diagnostics

Power, short, open load conditions and module health and configuration are monitored

Special Features

Integrated web server, Integrated 2 port switch and fail-safe device settings

Weight
POWERLINK® Communications Module

227g/8 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

23

ELECTRONICS

G3 Fieldbus

EtherCAT®

EtherCAT® is an open ethernet-based fieldbus protocol
developed by Beckhoff. EtherCAT® sets new standards
for real-time performance and topology flexibility with short
data update/cycle times and low communication jitter.
Numatics’ G3 EtherCAT® node has an integrated graphic
display for simplified commissioning and diagnostics. It is
capable of addressing combinations of up to 1200 outputs
and 1200 inputs.
The G3 nodes for EtherCAT® have been designed and
tested to conform with EtherCAT® specifications set forth
by the ETG.
More information regarding EtherCAT® can be obtained
from the following website: www.ethercat.org.

Technical Data
Electrical Data

Description

Replacement Part
Number

EtherCAT® communications
module (node)

240-310

Voltage

Current

Node Power at Max. Brightness
Valves and Discrete I/O

24 VDC +/- 10%
24 VDC +/- 10%

Power Connector

Single key 5 pin 7/8” MINI type (male)

Communication Connector

Two D-coded 4 pin M12 type (female)

LEDs

Module Status, Network Status and Activity/Link

Temperature Range

-23 ºC to 50 ºC (-10 ºF to 115º F)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC 60068-2-6

Moisture

IP65 (with appropriate assembly and termination)

Graphic Display

Display used for setting IP address, Subnet Mask, Fault/Idle Actions, and all other system settings

ARM

(Auto Recovery Module) Optional module that contains automatic recovery of system settings in the event of
total or partial system failure

Maximum Valve Solenoid Outputs

32

Maximum Sub-Bus I/O Points

Various combinations of 1200 outputs and 1200 inputs

8 Amps Maximum

Operating Data

Configuration Data

Network Data
Supported Baud Rates

10 Mbit/100 Mbit

Bus Connector

Two D-coded 4 pin M12 type (female)

Diagnostics

Power, short, open load conditions and module health and configuration are monitored

Special Features

Integrated web server, fail-safe device settings

Weight
EtherCAT® Communications Module

24

227g/8 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

ELECTRONICS

G3 Fieldbus
EtherNet/IP™ DLR

EtherNet/IP™ used throughout the world to network millions of PCs has now evolved
into a viable industry network. EtherNet/IP™ is an open architecture high-level
communication network that meets the demands of today’s industrial applications
requiring high-speed (10/100 Mbit/s), high-throughput and flexibility.
Additionally, EtherNet/IP™ technology can integrate an on-board web
server, which can make the node readily accessible to any standard
web browser for configuration, testing and even retrieval of technical
documentation.
Numatics’ G3 EtherNet/IP™ DLR (Device Level Ring) node with
integrated display has an embedded switch which allows the unit to
be used in simplified networks with linear topology configurations (daisy
chain). This technology alleviates the need for an external Ethernet switch
device in a single subnet configuration. Additionally, the DLR compatibility allows
the node to be used in a fault tolerant “ring” network, when using appropriate EtherNet/
IP™ DLR scanners. DLR configuration allows communication
Description
recovery from a single point failure on the network ring (e.g. failed
network connection or cable).

Replacement Part
Number

EtherNet/IP™ DLR communications
module (node)

Numatics G3 EtherNet/IP™ nodes are capable of addressing
combinations of up to 1200 outputs and 1200 inputs.

240-325

The G3 EtherNet/IP™ nodes have been tested and approved for conformance by the ODVA.
More information about EtherNet/IP™ and the ODVA can be obtained from the following website: www.odva.org.

Technical Data
Electrical Data

Voltage

Current

Node Power at Max. Brightness
Valves and Discrete I/O

24 VDC +/- 10%
24 VDC +/- 10%

Power Connector

Single key 4 pin 7/8” MINI type (male)

Communication Connector

Two D-coded 4 pin M12 type (female)

LEDs

Module Status, Network Status and Activity/Link

8 Amps Maximum

Operating Data
Temperature Range

-23 ˚C to 50 ˚C (-10 ˚F to 115˚ F)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC 60068-2-6

Moisture

IP65, IP67 (with appropriate assembly and termination)

Graphic Display

Display used for setting IP address, Subnet Mask, Fault/Idle Actions, and all other system settings

ARM

(Auto Recovery Module) Optional module that contains automatic recovery of system settings in the event of
total or partial system failure

Maximum Valve Solenoid Outputs

32

Maximum Sub-Bus I/O Points

Various combinations of 1200 outputs and 1200 inputs

Configuration Data

Network Data
Supported Baud Rates

10 Mbit/100 Mbit

Bus Connector

Two D-coded 4 pin M12 type (female)

Diagnostics

Power, short, open load conditions and module health and configuration are monitored

Special Features

Embedded two port switch, Device Level Ring (DLR) compatibility, Linear network topology, QuickConnect™
capability, fail-safe device settings, integrated web server, HTTP, TFTP, UNICAST

Weight
EtherNet/IP™ DLR Communications Module

227g/8 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

25

ELECTRONICS

G3 Fieldbus

CC-Link IE Field™

CC-Link IE Field™ is an open standard 1 Gbps Ethernet
Manufacturing network that enables seamless data
communication from the plant-level enterprise network to the
production floor network. The CC-Link Partner Association
(CLPA) oversees and manages CC-Link® specifications.
Numatics’ G3 nodes for CC-Link IE Field™ have an integrated
graphic display and are capable of addressing combinations of
up to 1200 outputs and 1200 inputs.
CC-Link IE Field™ is based on 1 Gbps Ethernet standards and
complements them with specific protocols and mechanisms to
achieve real time performance.
More information regarding CC-Link IE Field™ can be obtained
from the following website: www.CCLinkAmerica.org

Description

Replacement Part
Number

CC-Link IE Field™
communications module (node)

240-362

Technical Data
Electrical Data

Voltage

Node Power at Max. Brightness

24 VDC +/- 10%

Valves & Discrete I/O

24 VDC +/- 10%

Power Connector

Single key 5 pin 7/8” MINI type (male)

Communication Connector

Two X-coded 8 pin M12 type (female)

LEDs

Run, ERR, Link, D Link, L.ERR, L.ER

Current
8 Amps Maximum

Operating Data
Temperature Range (ambient)

-23 ºC to 50 ºC (-10 ºF to 115 ºF)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC60068-2-6

Moisture Protection

IP65 (with appropriate assembly and termination)

Graphic Display

Display used for setting Node Number, Network Number, Fault/Idle Actions, and all other system settings

ARM

(Auto Recovery Module) Optional module that contains automatic recovery of system setting in the event of
total or partial system failure

Maximum Valve-Solenoid Outputs

32

Maximum Addressable I/O Points

Various combinations of 1200 outputs and 1200 inputs

Configuration Data

Network Data
Supported Baud Rates

1 Gbps

Bus Connector

Two D-coded 8 pin M12 type (2-Female)

Diagnostics

Power, short, open load conditions and module health and configuration are monitored

Special Features

Integrated 2 port switch, fail-safe device settings

Weight
CC-Link IE Field™ Communications Module

26

269g/9.5 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

ELECTRONICS

G3 Fieldbus
I/O Modules

Digital Inputs - Terminal Strip Modules
Description

Part Number

16 PNP Inputs

240-203

16 NPN Inputs

240-204

8 PNP Inputs

240-316

16 PNP outputs

240-330

Technical Data
Operating Data
Temperature Range (ambient)

-23 ºC to 50 ºC (-10 ºF to 115 ºF)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC60068-2-6

Wire Range

12 to 24 AWG

Strip Length

7mm

Tightening Torque

0.5 Nm

Ingress Protection

IP20

Spare Parts
Replacement Terminal Strip (I/O 0-7)

140-1073

Replacement Terminal Strip (I/O 8-15)

140-1074

Keying Element for terminal strip

140-1076

Keying Element for Module

140-1077

Weight
Input Module

292g/10.3 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

27

ELECTRONICS

G3 Fieldbus

I/O Modules

Digital I/O 5-pin M12 Modules
Description

Part Number

Inputs

8 PNP Inputs

240-206

8 NPN Inputs

240-210

16 PNP Inputs

240-205

16 NPN Inputs

240-209

Outputs
8 PNP Outputs

240-208

8 PNP High Current
Outputs (Fig. A Only)

240-300

16 PNP Outputs

240-207

Inputs and Outputs
8 PNP Inputs and
8 PNP Outputs

240-211

Figure A

Analog I/O with settable high and low alarms
5-pin M12 Modules
Description

Signal Type

Inputs

Part Number

4 Analog Inputs

0-10 VDC

240-212

4 Analog Inputs

4-20 mA

240-214

Inputs and Outputs
2 Analog Inputs & 2 Analog Outputs

0-10VDC

240-213

2 Analog Inputs & 2 Analog Outputs

4-20 mA

240-215

2 Analog Inputs & 2 Analog Outputs
High Current (Figure A Only)

0-10 VDC

240-307

4 Analog Inputs & 4 Analog Outputs
High Current (Figure A Only)

4-20 mA

240-363

Technical Data
Operating Data
Temperature Range (ambient)

-23 ºC to 50 ºC (-10 ºF to 115 ºF)

Humidity

95% relative humidity, non-condensing

Vibration/Shock

IEC 60068-2-27, IEC60068-2-6

Ingress Protection

IP65, IP67 (with appropriate assembly
and termination)

Connector

M12 4 Pin Female, Speedcon
(Compatible with 5 Pin)

Resolution

16 bit

Dust Cover M12 Male 230-647

Weight

28

I/O Module-Analog

244g/8.6 oz.

I/O Module-Digital

274g/9.7 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

ELECTRONICS

G3 Fieldbus
G3 RTD Temperature Module 240-311

The RTD module is for use with RTD (Resistive Temperature Detectors), supporting
up to four RTD devices simultaneously. The module supports various RTD types
including: Pt100, Pt200, Pt500, Pt1000, Ni100 and Ni1000.

Technical Data

Electrical Data
Voltage

24 VDC Module Supply (Via G3 System Aux. Power Connection)

Input Type

RTD (Resistive Temperature Detector), 4 per Module

Supported Sensor Type

Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000

Supported Temperature Coefficients

.00385; .00392; ….Ω/Ω/°C

Resolution

15 bits plus sign

Data Format

Signed Integer

Calibration

Factory Calibrated Field Calibration w/high tolerance (± .005%)
100 ohm and 350 ohm resistors

Input Update (filter) Rate

Adjustable (5-20mS), factory default: 5ms

Accuracy

0.1% of full scale @ 25° C

Mechanical Data
I/O Connector

M12 4 Pin Female. Speedcon (Compatible with 5 Pin)

Mass

247g/8.7 oz.

Temperature Range Ambient

-23 ºC to 46 ºC (-10 ºF to 115 ºF )

Humidity

95% relative humidity: non-condensing

Ingress Protection

IP65 (with appropriate assembly and terminations)

Operating Data

240- 320 G3 [Ex ia] NAMUR Input Module

The [Ex ia] module is for use with NAMUR certified intrinsically safe (IS) sensors.

Technical Data

Electrical Data
24 VDC Module Supply
Sensor Supply = 8.2 VDC Nominal

Voltage
Input Type
NC (Normally Closed)

NAMUR
Signal Current (0) ≥ 2.1 mA
Signal Current (1) ≤ 1.2 mA
Short Circuit Monitoring < 100 Ω
Open/Broken Wire Detection < 0.05 mA

Safety Parameter Output Maximums

Uo ≤ 9.6 V
Io ≤ 13 mA
Po ≤ 31 mW

Diagnostics

Open (broken wire) and Short Circuit

Certification
Module Marking (ATEX)

II(1)GD
[Ex ia Ga] IIC [Ex ia Da] IIIC

Mechanical Data
I/O Connector

M12 4 Pin Female Speedcon (Compatible with 5 Pin)

Mass

284g/10.0 oz.

Temperature Range Ambient

-23 ºC to 46 ºC (-10 ºF to 115 ºF)

Humidity

95% relative humidity: non-condensing

Ingress Protection

IP65 (with appropriate assembly and terminations)

Operating Data

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

29

ELECTRONICS

G3 Fieldbus

Miscellaneous Modules
Auto Recovery Module (ARM)

Protects configuration information during a critical failure.
Allows configuration information to be saved and reloaded
to replacement module automatically.
Description
ARM Module

Part Number
240-182

Weight
127g/4.5 oz.

Terminator Module

Provides termination for the Sub-Bus. Must be installed
after the last I/O module or after the communications
module if there are no I/O modules installed.
Description

Part Number

Weight

Terminator Module
w/DIN Rail Clips

240-245

102g/3.6 oz.

Terminator Module

240-184

91g/ 3.2 oz.

Jumper Clip

Provides electrical connections between modules.
Description

30

Part Number

Weight

Jumper Clip

240-179

45g/1.6 oz.

Jumper Clip for Intrinsically Safe

240-317

65g/2.3 oz.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

ELECTRONICS

G3 Fieldbus
Miscellaneous Modules
Valve Driver Module

Provides connections between the communication module or
Sub-Bus valve module and the valve manifold.

501, 502 and 503 Series Valves
Description

Part Number

Valve Driver Module

P599AE508827001

Valve Driver Module
w/DIN Rail Clips

P599AE508827002

Right Hand Mounting Cover*

Used when a communications module is used without local
valves installed.
Description

Part Number

Weight

Right Hand Mounting Cover
w/DIN Rail Clips

240-290

82g/2.9 oz.

Right Hand Mounting Cover

240-255

71g/2.5 oz.

* Not for use in combination with ARM Module

Accessories

For use with Murrplastik© Type 20 Software.

Labels - 122-1251
Technical Data
Material

Polycarbonate (PC)

Color

White

Temperature Range

-40 ºC to 140 ºC
(-40 ºF to 284 ºF)

Label Dimensions

0.19" x 0.39"

Label - Printable Area

0.19" x 0.39"

{

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

31

ELECTRONICS

G3 Fieldbus

Dimensions: mm (Inches)

Dimensional Drawing - G3 Fieldbus Manifold Assembly

503 Series Valve Manifold Assembly with G3 Electronics and Sub-Bus Output

M

C

L

B

E

D

A

4

5.

Ø

6.3 Wide Slot
(2) Places

F

H

G

J

K

AD
Y

Z

AA

AB
P

Q

N

AC

X

W

R

S

T

U
V

*

32

A

B

C

D

E

F

G

H

J

K

L

M

N

P

105.5
(4.154)

6.3
(0.248)

38
(1.5)

52.8
(2.08)

33.8
(1.33)

7
(0.28)

57.5
(2.264)

67.5
(2.66)

71.7
(2.82)

–

39.1
(1.54)

75.8
(2.984)

68.1
(2.68)

56.3
(2.217)

Q

R

S

T

U

V

W

X

Y

Z*

AA

AB

AC

AD

54
(2.13)

24.8
(0.98)

67.5
(2.66)

36.9
(1.45)

221.3
(8.713)

368.6
(14.51)

12.5
(0.49)

24.8
(0.976)

53
(2.087)

–

55.1
(2.17)

101.1
(3.98)

112.9
(4.445)

207
(8.2)

For valve manifold dimensions refer to Valve Series product catalogs.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

ELECTRONICS

G3 Fieldbus
How to Order

Manifold Assembly

8

Port Type
8
G
K

=
=
=

503

A

V

3

B

3

0

0

V A00

Options

NPTF *
ISO228/1-G*

A00
MUF
DRM
DWM
14X
D12

= Standard (No Options)
= Muffler in End Plates
= DIN Rail Mount
= DIN Rail with MUF
=	External Pilot Supply from Port # 14
=	(14X) External Pilot Supply from Port #14 and (MUF)
Muffler in End Plates
D14 =	(14X) External Pilot Supply from Port #14 and
(DRM) DIN Rail Mount
F06 =	(14X) External Pilot Supply from Port #14, (MUF)
Muffler in End Plates, and (DRM) DIN Rail Mount
A45 = Zoned Pilot for End Plate Assembly Kit
D47 = A45 + MUF
D48 = A45 + DRM
D49 = 14X
F21 = A45 + DRM + MUF
F22 = A45 + 14X + MUF
F23 = A45 + 14X + DRM
K30 = A45 + 14X + DRM + MUF

Push-in Fittings

Product Series
503

=

26mm Valve

Revision
A

=

Initial Release

Product Type
V

=

Valve Manifold Assembly

Electronics
3

=

G3 Fieldbus Electronics

Number of Valve Stations
B
D
F
H
J
L
N
P
R
T

=
=
=
=
=
=
=
=
=
=

2
4
6
8
10
12
14
16
18
20

V
X
Z
3
5
7

=
=
=
=
=
=

22
24
26
28
30
32

End Plate Style
V

=

Vertical

Second Valve Series
0

=

No Second Valve Series

End Plate Port Size
3
4
K
M

* Port Type '8' and 'G' only available in Port Size '3'

=
=
=
=

3/8
1/2
10mm
12mm

G3 Electronics

G3
Series
G3

=

=
=
=
=
=
=
=

CC-Link IE Field
EtherCAT
EtherNet/IP DLR
Ethernet Modbus - TCP
EtherNet/IP
Ethernet POWERLINK
PROFINET

Number of I/O Modules
00
01
02
03
04
05
06
07
08

=
=
=
=
=
=
=
=
=

0
1
2
3
4
5
6
7
8

09
10
11
12
13
14
15
16

00

R

0

STD
Options

G3 Electronics

Electronics Protocol
CC1
EC1
ED1
EM1
EP1
PL1
PN1

EP1

=
=
=
=
=
=
=
=

STD
DRM
E40
G32

=
=
=
=

Standard
DIN Rail Mounting
Auto Recovery Module (ARM)
E40 + DRM

Modification
0

=

Initial Release

Left Mounting
R

=

w/Terminating Resistor

9
10
11
12
13
14
15
16

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

33

ELECTRONICS

G3 Fieldbus

Ordering Zoned Safety Manifolds with G3 Electronics and 503 Valves

Standard

Pilot Valves

Zone #1

Zoned Safety manifolds can be configured with a combination of
valves for non safety related applications and up to 3 independent
safety zones. Within each safety zone both power and pilot air to
the valves can be isolated.
• Any valves that are not part of the safety related functions must be
configured starting @ Station 1
• The “U” Wiring block is the beginning of the safety zone. Only 5/2
Single Solenoid /Spring return valves without override may be used.
Each valve corresponds to a safety zone. A manifold with 2 Safety
zones will have 2 valves with the “U” Wiring
• The “X” wiring block allows 0 and +24 VDC separation for a section of
the manifold while the remainder of the manifold remains operational.
Each “X” wiring block controls up to 16 solenoids
• If Pilot Zoning is required, must select “Zoned Pilot for End Plate
Assembly Kit” in the Valve Assembly number and option “83H” Pilot
Separation for Station 1 in the Manifold Assembly Kit
• Refer to the How to Order example to the right

34

Zone #2

Example Order - 503 Shown

Assembly Kit
Valve Station #1
Valve Station #2
Mounting #1
Valve Station #3
Accessory Station
Valve Station #4
Accessory Station
Mounting #2
Valve Station #5
Accessory Station
Valve Station #6
Mounting #3
Valve Station #7
Valve Station #8
Mounting #4
Valve Station #9
Accessory Station
Valve Station #10
Mounting #5
Valve Station #11
Valve Station #12
Mounting #6
Electronics
ASSEMBLED

#3
#4
#5

#9

8503AV3L300VA45
R503A2B40MA00F1
R503A2B40MA00F1
8503AMM22MA0010
R503A2B10M11MF1
K503AU516663006
R503A2B10M11MF1
K503AU516663010
8503AMS22UA010
R503A2B40MA00F1
K503AP48330010
R503A2B40MA00F1
8503AMM22X83H10
R503A2B40MA00F1
R503A2B40MA00F1
8503AMM22MA0010
R503A2B40MA00F1
K503AP48330010
R503A2B40MA00F1
8503AMM22X83H10
R503A2B40MA00F1
R503A2B40MA00F1
8503AMM22MA0010
G3EP100R0STD

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

S
T
A
N
D
A
R
D
P
I
L
O
T
V
A
L
V
E
S

Z
O
N
E
#
1

Z
O
N
E
#
2

G3 POWER
CABLES & CONNECTORS

G3
Electronics

7/8" MINI Cables

4 Pin Cables for DeviceNet™, DeviceLogix™, Ethernet,
Modbus TCP/IP, CANopen®, and Sub-Bus
7/8" MINI Straight 4 Pin Female Single Ended Cable, Euro Color Code
MC0405MAC0000000 – 5 Meter
MC0410MAC0000000 – 10 Meter

7/8" MINI 90° 4 Pin Female Single Ended Cable, Euro Color Code
MD0405MAC0000000 – 5 Meter
MD0410MAC0000000 – 10 Meter

5 Pin Cables for PROFIBUS® DP, PROFINET®,
POWERLINK®, and EtherCAT®
7/8" MINI Straight 5 Pin Female Single Ended Cable, Euro Color Code
MC0505MAG0000000 – 5 Meter
MC0510MAG0000000 – 10 Meter

7/8" MINI 90° 5 Pin Female Single Ended Cable, Euro Color Code
MD0505MAG0000000 – 5 Meter
MD0510MAG0000000 – 10 Meter

7/8" MINI Field Wireable Connectors

4 Pin Connectors for DeviceNet™, DeviceLogix™, Ethernet,
Modbus TCP/IP, CANopen®, and Sub-Bus
7/8" MINI Straight 4 Pin Female Field Wireable Connector
MC04F90000000000 –Cable Gland – One size fits all

7/8" MINI 90° 4 Pin Female Field Wireable Connector
MD04F20000000000 – PG 9 Cable Gland

5 Pin Connectors for PROFIBUS® DP, PROFINET® and
POWERLINK®, and EtherCAT®
7/8" MINI Straight 5 Pin Female Field Wireable Connector
MC05F90000000000 – Cable Gland – One size fits all

7/8" MINI 90° 5 Pin Female Field Wireable Connector
MD05F20000000000 – PG 9 Cable Gland

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

35

G3
Electronics
M12 to 7/8" MINI Cable

4 Pin Cable for Sub-Bus Power
M12 Straight 4 Pin Male to 7/8" MINI 4 Pin Female Extension
TA0401MA0MC0471T – 1 Meter
TA0405MA0MC0471T – 5 Meter
TA0410MA0MC0471T – 10 Meter

M12 Cables

4 Pin Cables for Sub-Bus Power				
M12 Straight 4 Pin Female Single Ended Cable, Euro Color Code
TC0405MAE0000000 – 5 Meter
TC0410MAE0000000 – 10 Meter

M12 90° 4 Pin Female Single Ended Cable, Euro Color Code
TD0405MAE0000000 – 5 Meter
TD0410MAE0000000 – 10 Meter

M12 Straight 4 Pin Male to Female Cable Extension
TC0401MAETA04000 – 1 Meter
TC0405MAETA04000 – 5 Meter
TC0410MAETA04000 – 10 Meter

M12 Field Wireable Connectors
4 Pin Connectors for Sub-Bus Power
M12 Straight 4 Pin Female Field Wireable Connector
TC04F10000000000 – PG 7 Cable Gland
TC04F20000000000 – PG 9 Cable Gland

M12 90° 4 Pin Female Field Wireable Connector
TD04F10000000000 – PG 7 Cable Gland
TD04F20000000000 – PG 9 Cable Gland

36

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

G3
Electronics
Pin Out and Technical Data
M12 Cable - Pin Out/Euro Color Code
(Male View)
1
2
3
4

7/8" MINI Cable - Pin Out/Euro Color Code
(Male View)
1
2
3
4

1
2
3
4
5

Technical Data

M12

7/8" MINI

Molded Body/Insert

Cable = PVC

Coupling Nut

Nickel Copper Alloy

Black Anodized Aluminum/Die Cast Zinc

Cable Jacket Material

PVC

PVC

Cable O.D.

7.4mm

7.4mm (4 Pin & 5 Pin)

Voltage Rating (Nominal)

250 V Max. @ 105 °C (221 °F)

250 V Max. @ 105 °C (221 °F)

Current Rating

Cables = 4.0 Amps

Cables = 5.5 Amps

Degree of Protection

IP67 (mated)

IP67 (mated)

Operating Temperature

-25 °C to 85 °C (-13 °F to 185 °F)

-40 °C to 85 °C (-40 °F to 185 °F)

Conductor Gauge

Cable = 18 AWG

Cable = 18 AWG

Bend Radius

Cable = 74mm

Cable = 74mm (4 Pin & 5 Pin)

Maximum Wire AWG

Field Wireable = 18 AWG

Field Wireable = 16 AWG

Wire Connection

Field Wireable = Screw Terminal

Field Wireable = Screw Terminal

PG 7 Range

4-6mm

N/A

PG 9 Range

6-8mm

5-13mm – One size fits all

PG 13.5 Range

N/A

5-13mm – One size fits all

Field Wireable = Polyamide

Field Wireable = 4.0 Amps

Cable = PVC

Field Wireable = Polyamide or PBT

Field Wireable = 8.0 Amps

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

37

G3
Electronics

G3 PROFINET®
CABLES & CONNECTORS
M12 D-Coded Cables

M12 Straight 4 Pin Male D-Coded Single Ended Cable
QA0405MR00000000 – 5 Meter
QA0410MR00000000 – 10 Meter

M12 Straight 4 Pin Male D-Coded Double Ended Cable
QA0405MR0QA04000 – 5 Meter
QA0410MR0QA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable
QA0405MR0VA04000 – 5 Meter
QA0410MR0VA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket Convertor
QA04D2MK0VC04000 – 0.2 Meter

M12 D-Coded Field Attachable CONNECTORS
M12 Straight 4 Pin Male D-Coded Field Wireable Connector
QA04F20000000000 – PG 9 Cable Gland – Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/IDC
QA04F200R000071N – PG 9 Cable Gland – IDC

RJ45 Field Attachable CONNECTOR
RJ45 Field Wireable Connector with IDC
VA08F200R000071N – PG 9 Cable Gland
4

M12 D-Coded Cable Pin Out/Color Code

(Male View)
1

38

3

2

1

YE

2

WH

3

OG

4

BU

Technical Data

Cable

RJ45 Field Attachable

M12 Field Attachable

Molded Body/Insert

TPU

Housing = PA Carrier = PC

Body = Nickel Plated Zinc
Insert = PA 66

Coupling Nut

Nickel Plated Zinc

N/A

Nickel Plated Brass

Cable Jacket Material

PVC

N/A

N/A

Cable O.D.

6.5 to 7.4mm

Accepts 4.5 to 8.0mm

Accepts 6.0 to 8mm

Voltage Rating (Nominal)

250 Volts

N/A

60 Volts

Current Rating

4.0 Amps

1.75 Amps

Screw 4.0 Amps IDC 1.75 Amps

Degree of Protection

IP65 (mated), RJ45 – IP20

IP20

IP 65 (mated)

Operating Temperature

-25 °C to 60 °C (-13 °F to 140 °F)

-10 °C to 60 °C (14 °F to 140 °F)

-40 °C to 85 °C (-40 °F to 185 °F)

Conductor Gauge

22 & 24 AWG

22 AWG Solid/Stranded

Screw 24-18 AWG
IDC 26-22 AWG

Bend Radius Minimum

19.5mm (fixed) 45.5mm (Flexible)

N/A

N/A

Wire Connection

NA

IDC

Screw Terminal, IDC

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

G3
Electronics

G3 POWERLINK®
CABLES & CONNECTORS
M12 D-Coded Cables
M12 Straight 4 Pin Male D-Coded Double Ended Cable
QA0405MS0QA04000 – 5 Meter
QA0410MS0QA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable
QA0405MS0VA04000 – 5 Meter
QA0410MS0VA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket
Converter
QA04D2MK0VC04000 – 0.2 Meter

M12 D-Coded Field Attachable CONNECTORS
M12 Straight 4 Pin Male D-Coded Field Wireable Connector
QA04F20000000000 – PG 9 Cable Gland – Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/
IDC
QA04F200R000071N – PG 9 Cable Gland – IDC

RJ45 Field Attachable CONNECTOR
RJ45 Field Wireable Connector with IDC
VA08F200R000071N – PG 9 Cable Gland

4

M12 D-Coded Cable & RJ45
Pin Out/Color Code

3

4

3 2

1

(Male View)

2
3

yellow
orange
white
blue

4

1

shield

shield
1

2

1

1

2

2

3

3

4

4

yellow
white
blue
orange

1
2
3
4

M12 to M12

RJ45 to M12

Technical Data

Cable

RJ45 Field Attachable

M12 Field Attachable

Molded Body/Insert

N/A

Housing = PA Carrier = PC

Body = Nickel Plated Zinc
Insert = PA 66

Coupling Nut

Nickel Plated Zinc or Brass

N/A

Nickel Plated Brass

Cable Jacket Material

PUR

N/A

N/A

Cable O.D.

6.5mm

Accepts 4.5 to 8.0mm

Accepts 6.0 to 8mm

Voltage Rating (Nominal)

N/A

N/A

60 Volts

Current Rating

N/A

1.75 Amps

Screw 4.0 Amps

Degree of Protection

IP65 (mated), RJ45 – IP20

IP20

IP 65 (mated)

Operating Temperature

-25 °C to 60 °C (-13 °F to 140 °F)

-10 °C to 60 °C (14 °F to 140 °F)

-40 °C to 85 °C (-40 °F to 185 °F)

Conductor Gauge

22 AWG

22 AWG Solid/Stranded

Screw 24-18 AWG

Bend Radius Minimum

45.5mm

N/A

N/A

Wire Connection

N/A

IDC

Screw Terminal, IDC

IDC 1.75 Amps

IDC 26-22 AWG

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

39

G3
Electronics

G3 ETHERCAT® CABLES
& CONNECTORS
M12 D-Coded Cables
M12 Straight 4 Pin Male D-Coded Single Ended Cable
QA0405MT00000000 – 5 Meter
QA0410MT00000000 – 10 Meter

M12 Straight 4 Pin Male D-Coded Double Ended Cable
QA0405MT0QA04000 – 5 Meter
QA0410MT0QA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable
QA0405MT0VA04000 – 5 Meter
QA0410MT0VA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket Convertor
QA04D2MK0VC04000 – 0.2 Meter

M12 D-Coded Field Attachable Connectors
M12 Straight 4 Pin Male D-Coded Field Wireable Connector
QA04F20000000000 – PG 9 Cable Gland – Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/IDC
QA04F200R000071N – PG 9 Cable Gland – IDC

RJ45 Field Attachable Connector
RJ45 Field Wireable Connector with IDC
VA08F200R000071N – PG 9 Cable Gland
4

M12 D-Coded Cable Pin Out/Color Code

(Male View)
1

40

3

2

(1658435)

1

YE

2

WH

3

OG

4

BU

Technical Data

Cable

RJ45 Field Wireable

M12 Field Attachable

Molded Body/Insert

TPU/PE

Housing = PA Carrier = PC

Nickel Plated Zinc/PA 66

Coupling Nut

Nickel Plated Zinc

NA

Nickel Plated Brass

Cable Jacket Material

PVC

NA

NA

Cable O.D.

6.5mm

Accepts 4.5 to 8.0mm

Accepts 4.0 to 8mm

Voltage Rating (Nominal)

250 Volts

NA

60 Volts

Current Rating

4.0 Amps

1.75 Amps

Screw 4.0 Amps

Degree of Protection

IP65 (mated), RJ45 – IP20

IP20

IP 65 (mated)

Operating Temperature

-40 °C to 70 °C (-40 °F to 158 °F)

-10 °C to 60 °C (14 °F to 140 °F)

-40 °C to 85 °C (-40 °F to 185 °F)

Conductor Gauge

22 & 24 AWG

22 AWG Solid/Stranded

Screw 24-18 AWG

Bend Radius Minimum

19.5mm (fixed) 45.5mm (Flexible)

NA

NA

Wire Connection

NA

IDC

Screw Terminal, IDC

IDC 1.75 Amps

IDC 26-22 AWG

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

G3 ETHERNET/IP™ETHERNET/IP™ DLR &
MODBUS TCP/IP CABLES
& CONNECTORS

G3
Electronics

M12 D-Coded Cables
M12 Straight 4 Pin Male D-Coded Single Ended Cable
QA0405MK00000000 – 5 Meter
QA0410MK00000000 – 10 Meter

M12 Straight 4 Pin Male D-Coded Double Ended Cable
QA0405MK0QA04000 – 5 Meter
QA0410MK0QA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to Male RJ45 Cable
QA0405MK0VA04000 – 5 Meter
QA0410MK0VA04000 – 10 Meter

M12 Straight 4 Pin Male D-Coded to RJ45 Female Socket Convertor
QA04D2MK0VC04000 – 0.2 Meter

M12 D-Coded Field Wireable Connectors
M12 Straight 4 Pin Male D-Coded Field Wireable Connector
QA04F20000000000 – PG 9 Cable Gland – Screw Terminal

M12 Straight 4 Pin Male D-Coded Field Wireable Connector W/IDC
QA04F2000000071N – PG 9 Cable Gland – Screw Terminal

RJ45 Field Wireable Connector
RJ45 Field Wireable Connector with IDC
VA08F2000000071N – PG 9 Cable Gland

M12 D-Coded Cable Pin Out/Color Code

(Male View)

Technical Data

Cable

RJ45 Field Wireable

M12 Field Attachable

Molded Body/Insert

TPU, PA, PA66

Housing = PA Carrier = PC

Body = Nickel Plated Zinc

Coupling Nut

Nickel Plated Zinc or Brass

NA

Nickel Plated Brass

Cable Jacket Material

PUR or PVC

NA

NA

Cable O.D.

0.67 to 8.0mm

4.5 to 8.0mm

6.0 to 8.0mm

Voltage Rating (Nominal)

42 Volts

NA

60 Volts

Current Rating

1.5 Amps

1.75 Amps

Screw 4.0 Amps

Degree of Protection

IP65 (mated)

IP20

IP 65 (mated)

Operating Temperature

-20 °C to 60 °C (-4 °F to 140 °F)

-20 °C to 70 °C (-4 °F to 158 °F)

-40 °C to 85 °C (-40 °F to 185 °F)

Conductor Gauge

26 & 24 AWG

26-22 AWG Solid/Stranded

Screw 24-18 AWG

Bend Radius

40mm

NA

NA

Wire Connection

NA

IDC

IDC, Screw Terminal

Insert = PA 66

IDC 1.75 Amps

IDC 26-22 AWG

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

41

G3
Electronics

G3 I/O CABLES
& CONNECTORS
I/O Cables with SPEEDCON® Connector Technology
M12 Straight 4 Pin Male Single Ended Cable, Euro Color Code
TA04E5MIE000071P – 1.5 Meter
TA0403MIE000071P – 3 Meter
TA0405MIE000071P – 5 Meter

M12 90° 4 Pin Male Single Ended Cable, Euro Color Code
TB04E5MIE000071P – 1.5 Meter
TB0403MIE000071P – 3 Meter
TB0405MIE000071P – 5 Meter

M12 Straight 4 Pin Male to Female Cable Extension
TC04E5MIETA0471P – 1.5 Meter
TC0403MIETA0471P – 3 Meter

M12 Straight 3 Pin Male to M8 3 Pin Straight Female Extension
TC03E5MIEPA0371P – 1.5 Meter
TC0303MIEPA0371P – 3 Meter

I/O Connectors
M12 Straight 4 Pin Male Field Wireable Connector, IDC Connection
TA04F2000000081E – PG 9 Cable Gland w/SPEEDCON® connector technology

M12 Straight 4 Pin Male Field Wireable Connector, Screw Terminal
TA04F10000000000 – PG 7 Cable Gland
TA04F20000000000 – PG 9 Cable Gland

M12 90° 4 Pin Male Field Wireable Connector, Screw Terminal
TB04F10000000000 – PG 7 Cable Gland
TB04F20000000000 – PG 9 Cable Gland

I/O Splitters
M12 to M12 “Y” Splitter, 21mm Spacing
TA0500000JC05000

M12 to M8 “Y” Splitter
TA0400000KC03000

42

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

G3
Electronics

M12 Cable Splitter, 2 Straight M12 Female Connectors
TA04D3MIEJC04000 – 0.3 Meter
TA04E5MIEJC04000 – 1.5 Meter
TA0403MIEJC04000 – 3.0 Meter

M12 Cable Splitter, 2 Straight M8 Female Connectors
TA04D3MIEKC03000 – 0.3 Meter
TA04E5MIEKC03000 – 1.5 Meter
TA0403MIEKC03000 – 3.0 Meter

Wire Stripper Tool
140-1097

I/O Cable Connector Pin Out Diagrams
M12 Cable - Pin Out/Color Code

M12 Cable - Pin Out/Color Code

M12 Cable - Pin Out/Color Code

TA04XXMIE0000000,
TB04XXMIE0000000

TC03XXMIEPA0371P

TC03XXMIEPA0371P

(Male to Female View)

(Male to Female View)

M12 to M12 "Y" Splitter - Pin Out

M12 to M8 "Y" Splitter - Pin Out

M12 Field Wireable (IDC) - Pin Out

TA0500000JC05000

TA0400000KC03000

TA04F2000000081E (SPEEDCON®)

(Male to Female View)

(Male to Female View)

(Male View)

M12 to M12 Cable Splitter - Pin Out

M12 to M8 Cable Splitter - Pin Out

TA04XXMIEJC04000

TA04XXMIEKC03000

(Male to Female View)

(Male to Female View)

(Male View)

NOTE:
XX denotes allowable length.
See pages 42 & 43.

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

43

G3
Electronics
Cable and Connector Technical Data

44

Technical Data

M12 Cables

M12/M8 Cables

M12 Connectors

Molded Body/Insert

TPU

TPU

Polyamide (or) PA 66

Coupling Nut

Nickel Plated Zinc

Nickel Plated Zinc

Nickel Plated Zinc

Cable Jacket Material

PUR

PUR

NA

Cable O.D.

4.70mm

4.70mm

PG7 4.0 to 6.0mm
PG9 4.0 to 8.0mm

Voltage Rating

250 Volts

60 Volts

50 Volts

Current Rating (Cond.)

4.0 Amps

3.0 Amps

4.0 Amps

Degree of Protection

IP65 (mated)

IP65 (mated)

IP67 (mated)

Operating Temperature

-25 ºC to 80 ºC (-13 °F to 176 °F)
(fixed instl.)

-25 ºC to 80 ºC (-13 °F to 176 °F)
(fixed instl.)

-25 ºC to 80 ºC (-13 °F to 176 °F)

Conductor Gauge

22 AWG

22 AWG

22 AWG Min. 18 AWG Max.

Bend Radius

47mm

47mm

NA

Technical Data

I/O "Y" Splitter

I/O Cable Splitter

Molded Body/Insert

TPU

TPU

Coupling Nut

Nickel Plated Zinc

Nickel Plated Zinc

Cable Jacket Material

NA

PUR

Cable O.D.

NA

4.40mm

Voltage Rating

60 Volts

60 Volts

Current Rating (Cond.)

3.0 Amps

3.0 Amps

Degree of Protection

IP67 (mated)

IP67 (mated)

Operating Temperature

-25 ºC to 90 ºC (-13 °F to 194 °F)

-25 ºC to 80 ºC (-13 °F to 176 °F)

Conductor Gauge

NA

22 AWG or 24 AWG

Bend Radius

NA

44mm

Technical Data

Wire Stripper

Use with

PVC Insulation

Stripping Range

28 AWG to 10 AWG

Cutting Range (Flexible)

10 AWG

Cutting Range (Rigid)

12 AWG

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

SERIES

NOTES

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

503

45

SERIES

503

46

NOTES

Information subject to change without notice. For ordering information or regarding your local sales office visit www.asco.com.

World Headquarters
USA - Numatics, Incorporated

Canada - Numatics, Ltd

México - Ascomatica SA de CV

Brazil - Ascoval Ind.e Comercio Ltda

46280 Dylan Drive
Novi, Michigan 48377

P: 519-758-2700
F: 519-758-5540

P: 52 55 58 09 56 40 (DF y Area metropolitana)
P: 01 800 000 2726 (Interior de la República)
F: 52 55 58 09 56 60

P: (55) 11-4208-1700
F: (55) 11-4195-3970

P: 248-596-3200
F: 248-596-3201

LT-503ZSeries Rev 05/16
10M-Walsworth-09/12
© Numatics Inc. 2012-2016

Numatics, Inc. | Tel (248) 596-3200 | www.asco.com | email: an.insidesales@emerson.com

Numatics is registered in the United States and elsewhere
®



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00
Create Date                     : 2016:06:02 08:49:29-04:00
Metadata Date                   : 2016:06:02 08:51:01-04:00
Modify Date                     : 2016:06:02 08:51:01-04:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Instance ID                     : uuid:c1c95c1f-b023-3c4a-bb2b-a98be6741f52
Original Document ID            : adobe:docid:indd:1f8985b7-8cf8-11e0-be7a-94c10fc2012e
Document ID                     : xmp.id:3bc27ff5-8b5e-47ab-b1bd-dbdcb437be32
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:6ea813aa-a29d-4efe-b66a-1b53d64cb4eb
Derived From Document ID        : xmp.did:f7003161-19c4-4297-9661-f6d42342f990
Derived From Original Document ID: adobe:docid:indd:1f8985b7-8cf8-11e0-be7a-94c10fc2012e
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2016:06:02 08:49:29-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 56
Creator                         : Adobe InDesign CC 2015 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu