Flow Reer Switches And Sensors 1505494185 User Manual
Reer Switches And Sensors-1505494185 REER_SWITCHES_AND_SENSORS-1505494185
2017-10-06
User Manual: Flow Reer Switches And Sensors-1505494185
Open the PDF directly: View PDF .
Page Count: 40
Download | |
Open PDF In Browser | View PDF |
Safety. Detection. Control. new new SAFETY SENSORS Safety Contactless Sensors and Devices Issue 1 Product catalogue SAFETY CONTACTLESS SENSORS AND DEVICES OVERVIEW Magnus RFID: next generation sensors for machine safety Available with 22 or 78 mm interaxis 3 different coding levels new M12 connector pigtail or 5 meters cable State-of-the-art RFID technology Magnus RFID RFID safety switch See page 4 2 Anti-tampering protective caps IP67 and IP69K approved SAFETY CONTACTLESS SENSORS AND DEVICES OVERVIEW Pharo Type 3 laser scanner See page 17 Ilion Type 2 safety photocells See page 21 Ulisse Type 2 safety photocells See page 23 Magnus MG Magnetic safety switches See page 11 new Safety switch with guard locking See page 25 3 PL e, SIL 3 RFID SAFETY SENSORS MAGNUS RFID OVERVIEW The application of Magnus RFID sensors can be extremely wide thanks to the compact and versatile design. The different design and technology options and the complete mechanical compatibility with Magnus MG series make this product extremely valuable for users. The RFID technology enables Magnus RFID sensors to be individually coded in three different ways to allow the appropriate tampering protection in all applications. The highest configurations allow each sensor to be paired with one only assigned actuator. The best in cost-effectiveness ■■ Wear-free technology allows for longer life time ■■ Status LED and diagnostic output ■■ Smallest design of RFID safety sensors ■■ Full mechanical compatibility with Magnus MG S The RFID technology used allows to reach safety levels up to PL e / SIL 3 also when connecting the sensors in series. As a result, Magnus RFID sensors can be simply integrated in existing safety scenarios, offering a cost-effective solution for modifying and upgrading machines. and MG B ■■ Can be used as a stand-alone The best in safety ■■ Tampering protection in accordance with DIN EN 14119, the highest in its class ■■ Screw covers prevent easy removal ■■ Series connection up to PL e / SIL 3 Multiple options of actuation technology The best in versatility ■■ Dual mounting options ■■ M12 connector or cable ■■ IP67 and IP6K9K protection grade for use in harsh environments ■■ Complies with the strict hygiene and cleaning requirements of the food and packaging industry ■■ 3 different coding levels ■■ Extension cables for series connection Operating temperature: -25 ... +70 °C -25 ... +70 ºC IP65 IP67 IP6K9K The actuator is programmed via teach-in and permanently assigned to the sensor during set-up (the process can be repeated if necessary) ■■ Unique coding The actuator is permanently assigned to the sensor during manufacturing (it cannot be replaced with another actuator) ■■ Actuator coded The actuator is free and not specifically assigned to the sensor (one actuator can work with multiple sensors) Ideal also in the most demanding applications High protection classes IP67 and IP6K9K for use in harsh environments. Resistant to aggressive media, e.g. cleaning agents used in the food industry. Vibration resistance: 10…55 Hz, amplitude 1 mm. 4 ■■ Individual coding Unique mechanical characteristics allow protection againts cleaning agents and washdown processes, a typical requirement of the food industry. PL e, SIL 3 RFID SAFETY SENSORS MAGNUS RFID SERIES CONNECTION WITH MAXIMUM SAFETY Up to (PL e Performance Level) according to EN ISO 13849-1 Reliable evaluation, e.g. with the modular safety controller Mosaic... …or with the AD SR1 configurable safety control unit Transition time between Input and Output: 3 ms, the shortest in the market I O MAGNUS RFID RANGE S series 22 mm interaxis B series 78 mm interaxis Dimensions compatible with Magnus MG S series Dimensions compatible with Magnus MG B series CONNECTIVITY Cable or M12 Connector Magnus RFID satisfies all requirements with regard to connectivity. Cable (5 m) M12 Connector (15 cm pigtail) 5 PL e, SIL 3 RFID SAFETY SENSORS MAGNUS RFID CODE LEGEND (ORDERING INFORMATION) Combo (Sensor + Actuator)1 M RFID C S I A Extension cable (for series connection) M RFID EC 5 M 5 M12 Connector 5 m cable A Automatic EDM input I U C Individual coding Unique coding Actuator coded S B 22 mm interaxis 78 mm interaxis T Connectors (for series connection) M RFID TC A A B C S 4 5 1 3 5 10 1 m cable 3 m cable 5 m cable 10 m cable 4 4 poles connector 4 wires cable 8 8 poles connector 8 wires cable S Male - Female M12 connector (straight) L Male - Female M12 connector (90°)2 C Female M12 connector Accessories M12 Type A M12 Type B M12 Type C M RFID SP Spacers available for S or B series (recommended for mounting on metal surfaces) M RFID TP Termination plug (to close the last Type B connector in series connections of 2 or more sensors) 1. Each Combo set is provided with a Sensor and the corresponding Actuator. Sensors and Actuators can be also ordered separately, please enquire within 2. 4-pole version available only APPROVALS •• •• •• •• •• •• •• •• 2006/42/EC “Machine Directive” 2014/30/EC “Electromagnetic Compatibility Directive” 2014/35/EC “Low Voltage Directive” IEC 61508-1 (ed. 2) (SIL3) “Functional safety of electrical/electronic programmable electronic safety related systems General requirements” IEC 61508-2 (ed. 2) (SIL3) “Functional safety of electrical/electronic/programmable electronic safety related systems Requirements for electrical/electronic/programmable electronic safety-related systems” IEC 61508-3 (ed. 2) (SIL3) “Functional safety of electrical/electronic programmable electronic safety related systems: Software requirements” IEC 62061: “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” ISO 13849-1:2015 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” SAFETY LEVEL Cat. E S P E 6 4 SIL 3 - SILCL 3 PL e PL e, SIL 3 RFID SAFETY SENSORS MAGNUS RFID TECHNICAL FEATURES Electrical specifications S series / B series Supply voltage (VDC) S series Max. switching voltage (V) B series Max. 400 Switching current control output (mA) Max. 50 Contact form S series Housing material Housing Connector type Cable B series PBT / PC Rectangular Pigtail M12 / 8-pole / 150mm 5 m PVC / 8 wires Cross-section of wire (mm2) Dimensions h w d (mm) Fastening 26 x 36 x 13 26 x 88 x 13 M4 screws (countersunk) Environmental features Protection class Operating temperature Shock resistance Vibration resistance (Hz) Input-Output: 3 Sensor-Actuator: 75 OSSD Switching frequency (Hz) 3 No. of safety outputs electronic 2 No. of diagnostic outputs electronic 1 Number of safety inputs 2 EDM input Yes Start button Yes Functional category DC-12 / DC-13 Assured switching distance (mm) 8 Safe distance for switching off (mm) 18 Minimum air-gap (mm) 0,5 Misalignment actuator max. (mm) 0,25 Supply voltage ± 0,2 V Switching current safety output (mA) Response time (ms) Mechanical data 24 ± 10% Max. 8 Reverse polarity protection Yes Short-circuit proof outputs Yes Current consumption per input (mA) 2,75 Indication LED Three-colour S series / B series Operating direction Any direction IP67 (all versions) IP6K9K (cable versions only) Switching principle Electronic - 25 °C ... +70 °C 30 g /11 ms 10…55 , amplitude 1 mm Repeating accuracy R (mm) Hysteresis (mm) Series connection Technology < 0,5 2 Max. 30 sensors RFID 7 PL e, SIL 3 RFID SAFETY SENSORS MAGNUS RFID PART NUMBERS Combo (Sensor + Actuator) 22 mm interaxis Ordering code Models Connection 1292000 MRFID C S CA M M12 connector 1292003 MRFID C S CA 5 5 m cable 1292010 MRFID C S IA M M12 connector 1292013 MRFID C S IA 5 5 m cable 1292020 MRFID C S UA M M12 connector 1292023 MRFID C S UA 5 5 m cable Description Actuator coded Individual coding Unique coding Combo (Sensor + Actuator) 78 mm interaxis Ordering code 1292100 1292103 1292110 1292113 1292120 1292123 Models MRFID C B CA M MRFID C B CA 5 MRFID C B IA M MRFID C B IA 5 MRFID C B UA M MRFID C B UA 5 Connection M12 connector 5 m cable M12 connector 5 m cable M12 connector 5 m cable Description Actuator coded Individual coding Unique coding Individual sensors 22 mm interaxis Ordering code 1292200 1292203 1292210 1292213 Models MRFID S S CA M MRFID S S CA 5 MRFID S S IA M MRFID S S IA 5 Connection M12 connector 5 m cable M12 connector 5 m cable Description Actuator coded Individual coding Individual sensors 78 mm interaxis Ordering code 1292300 1292303 1292310 1292313 Models MRFID S B CA M MRFID S B CA 5 MRFID S B IA M MRFID S B IA 5 Connection M12 connector 5 m cable M12 connector 5 m cable Models MRFID A S MRFID A B Description Actuator for sensors 22 mm interaxis Actuator for sensors 78 mm interaxis Models MRFID SP S MRFID SP B Description Spacer for sensors 22 mm interaxis Spacer for sensors 78 mm interaxis Individual actuators Ordering code 1292290 1292390 Spacers Ordering code 1292401 1292400 CABLES AVAILABLE ■■ Male - Female M12 4-pole or 8-pole straight connectors. See page 36 ■■ Male - Female M12 4-pole 90° angled connectors. See page 36 ■■ Female M12 4-pole or 8-pole connectors. See page 37 ■■ Type A, D, C T connectors. See page 37 ■■ Termination plug. See page 37 8 Description Actuator coded Individual coding PL e, SIL 3 RFID SAFETY SENSORS MAGNUS RFID MECHANICAL DATA DIMENSIONS S series B series Cable version Cable version 22 13 13 36 9,5 25 9,5 18,5 Sensor 19 25,9 Sensor 78 88 Actuator Actuator M12 Connector version M12 Connector version 150 Sensor Sensor Actuator Actuator Spacer B 78 25 4,5 18,5 19 26 Ø 4,5 36 7 Spacer S 22 3,5 150 4,5 10 10 88 Dimensions: mm ACCESSORIES T Connectors 8 Extension cables 8 8 2 A B C 4 4 4 3 Type S Male - Female M12 connector (straight) Lenght: 1, 3, 5, 10 m Poles: 4 or 8 4 Type A To gain status output from the connected sensor Type B For series connections of 2 or more sensors Type C To introduce additional power supplies in long series Type L Male - Female M12 connector (90°) Lenght: 1, 3, 5, 10 m Poles: 4 Type C Female M12 connector Lenght: 1, 3, 5, 10 m Poles/wires: 4 or 8 9 PL e, SIL 3 RFID SAFETY SENSORS MAGNUS RFID CIRCUIT DIAGRAM 2 PIN-OUT Inputs 6 Pin 1 2 3 4 5 6 7 8 OSSD 4 8 EDM 7 Receiver Actuator 1 + - 3 5 Function VDC Safety input 1 GND Safety output 1 Diagnostic output Safety input 2 Safety output 2 EDM input 1 7 8 6 2 5 3 4 Power SERIES CONNECTION EXAMPLE M RFID EC C 4 1 M RFID EC C 4 3 M RFID EC C 4 5 M RFID EC C 4 10 M RFID TP Termination plug 4 4 4 4 M RFID EC L 4 1 M RFID EC L 4 3 M RFID EC L 4 5 M RFID EC L 4 10 Male - Female M12 connector (90°) Lenght: 1, 3, 5, 10 m Poles: 4 M RFID TC B Series connection Type B 8 8 M RFID EC L 4 1 M RFID EC L 4 3 M RFID EC L 4 5 M RFID EC L 4 10 4 4 4 3 Type C 2 Female M12 connector Lenght: 1, 3, 5, 10 m Poles/wires: 4 Male - Female M12 connector (90°) Lenght: 1, 3, 5, 10 m Poles: 4 4 4 4 4 M RFID TC C Additional power supply M RFID TC B Series connection Type B 8 8 4 M RFID TC A Status output Type A M RFID EC S 8 1 M RFID EC S 8 3 M RFID EC S 8 5 M RFID EC S 8 10 M RFID EC S 4 1 M RFID EC S 4 3 M RFID EC S 4 5 M RFID EC S 4 10 Male - Female M12 connector (straight) Lenght: 1, 3, 5, 10 m Poles: 8 Male - Female M12 connector (straight) Lenght: 1, 3, 5, 10 m Poles: 4 8 4 8 4 4 8 4 M RFID EC C 4 1 M RFID EC C 4 3 M RFID EC C 4 5 M RFID EC C 4 10 M RFID TC A Status output Type A 8 4 8 4 M RFID C S series M RFID C B series M RFID EC C 4 1 M RFID EC C 4 3 M RFID EC C 4 5 M RFID EC C 4 10 M RFID EC C 4 1 M RFID EC C 4 3 M RFID EC C 4 5 M RFID EC C 4 10 Female M12 connector Lenght: 1, 3, 5, 10 m Poles/wires: 4 M RFID C S series M RFID C B series 10 8 Female M12 connector Lenght: 1, 3, 5, 10 m Poles/wires: 4 M RFID C S series M RFID C B series M RFID EC C 8 1 M RFID EC C 8 3 M RFID EC C 8 5 M RFID EC C 8 10 8 8 Female M12 connector Lenght: 1, 3, 5, 10 m Poles/wires: 8 MAGNETIC SAFETY SWITCHES MAGNUS MG MG S M MG S RECTANGULAR COMPACT HOUSING TECHNICAL FEATURES MG S 20 Compact and robust thermoplastic enclosure (PBT). 22 mm fixing. Coded magnetic operation – Tamper resistant. Can be connected to Mosaic safety configurable controller (PL e) or to the dedicated safety control unit MG d1 (PL d). MG S switches connected to Mosaic safety controller form a certified PL e safety system. Switching distance: 3 - 10 mm. Sensor with 4 wires: 2 NO contacts. Operating voltage (VDC) 24 Switching current (mA) Max. 100 Series resistance (Ohm) 22 Switching power (W) 3 Shock resistance (Hz/g) 10 - 2000/35 Housing material PBT Possible actuation magnets MG S M to be ordered separately PART NUMBERS Magnus MG S includes multi-language instruction manual and CE declaration of conformity. MG S 20 ordering code: 1291000 MG S M ordering code: 1291001 CABLES NEEDED M8 4-pole. See page 33 (CGx, CG9x) ACCESSORIES Operating temperature: -25 ... +75 °C MG d1 Control Unit. See page 31 -25 ... +75 ºC CONNECTOR M8 4-pole connector. IP67 rating IP67 1 WH BN 2 3 GN YE 4 M8x1 IP65 3 1 4 2 11 MAGNETIC SAFETY SWITCHES MAGNUS MG APPROVALS Safety Level •• •• •• •• PL e when connected to Mosaic Up to PL d when connected to MG d1 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” EN 61508-1:1998 “Functional safety of electrical/electronic programmable electronic safety related systems - General requirements” EN 61508-2:2000 “Functional safety of electrical/electronic/programmable electronic safety related systems - Requirements for electrical/electronic/programmable electronic safety-related systems” EN 61508-3:1998 “Functional safety of electrical/electronic programmable electronic safety related systems: Software requirements” ISO 13849-1:2008 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” IEC 62061: “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” •• •• •• •• MECHANICAL DATA DIMENSIONS 13 19 26 5 36 Gaps (operating distance) for safe switching function in mm: 22 MINIMUN GAP 0,5 - ON 3 a OFF 10 b a b 4,5 8,5 12 Dimensions: mm MAGNETIC SAFETY SWITCHES MAGNUS MG MG B MG B M MG B M+ RECTANGULAR HOUSING TECHNICAL FEATURES Operating voltage (VDC) 24 MG B 20 Robust thermoplastic enclosure (PBT). 78 mm fixing. Coded magnetic operation – Tamper resistant. Can be connected to Mosaic safety configurable controller (PL e) or to the dedicated safety control unit MG d1 (PL d). MG B switches connected to Mosaic safety controller form a certified PL e safety system. Switching distance: ■■ 4 - 16 mm ■■ 7 - 18 mm with magnet MG B M+ Sensor with 4 wires: 2 NO contacts Switching current (mA) Max. 100 Series resistance (Ohm) 22 Switching power (W) 3 Shock resistance (Hz/g) 10 - 2000/35 Housing material PBT Possible actuation magnets MG B M to be ordered separately Possible actuation reinforced magnets MG B M+ to be ordered separately (only use reinforced actuation magnets if a gap of more than 4 mm is unavoidable) PART NUMBERS Magnus MG M includes multi-language instruction manual and CE declaration of conformity. MG B 20 ordering code: 1291010 MG B M ordering code: 1291011 MG B M+ ordering code: 1291012 CABLES NEEDED M8 4-pole. See page 33 (CGx, CG9x) Operating temperature: -25 ... +75 °C -25 ... +75 ºC ACCESSORIES MG d1 Control Unit. See page 31 IP65 IP67 IP67 rating CONNECTOR M8 4-pole connector 1 WH BN 2 3 GN YE 4 3 1 4 2 M8x1 13 MAGNETIC SAFETY SWITCHES MAGNUS MG APPROVALS Safety Level •• •• •• •• •• •• •• •• PL e when connected to Mosaic Up to PL d when connected to MG d1 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” EN 61508-1:1998 “Functional safety of electrical/electronic programmable electronic safety related systems - General requirements” EN 61508-2:2000 “Functional safety of electrical/electronic/programmable electronic safety related systems Requirements for electrical/electronic/programmable electronic safety-related systems” EN 61508-3:1998 “Functional safety of electrical/electronic programmable electronic safety related systems: Software requirements” ISO 13849-1:2008 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” IEC 62061: “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” MECHANICAL DATA DIMENSIONS 88 18,5 Gaps (operating distance) for safe switching function in mm: 14 5 78 4,5 25 a Dimensions: mm 14 b MINIMUM GAP normal with + magnet 0,5 3 ON normal with + magnet 4 7 a OFF normal with + magnet 16 18 b + = reinforced MAGNETIC SAFETY SWITCHES MAGNUS MG MG M 20 MG M M MG M M+ CYLINDRICAL HOUSING TECHNICAL FEATURES MG M 20 Robust cylindrical thermoplastic enclosure. 30 mm diameter. Coded magnetic operation – Tamper resistant. Can be connected to Mosaic safety configurable controller (PL e) or to the dedicated safety control unit MG d1 (PL d). MG M switches connected to Mosaic safety controller form a certified PL e safety system. Switching distance: ■■ 4 - 16 mm ■■ 7 - 20 mm with magnet MG M M+ Sensor with 4 wires: 2 NO contacts. Operating temperature: -25 ... +75 °C -25 ... +75 ºC Operating voltage (VDC) 24 Switching current (mA) max. 100 Series resistance (Ohm) 22 Switching power (W) 3 Shock resistance (Hz/g) 10 - 2000/35 Housing material PBT Possible actuation magnets MG M M to be ordered separately Possible actuation reinforced magnets MG M M+ to be ordered separately (only use reinforced actuation magnets if a gap of more than 4 mm is unavoidable) PART NUMBERS Magnus MG M 20 includes multi-language instruction manual and CE declaration of conformity MG M 20 ordering code: 1291020 MG M M ordering code: 1291021 MG M M+ ordering code: 1291022 CABLE NEEDED M8 4-pole. See page 33 (CGx, CG9x) ACCESSORIES IP65 rating MG d1 Control Unit. See page 31 IP67 CONNECTOR M8 4-pole connector 1 WH BN 2 3 GN YE 4 M8x1 IP65 3 1 4 2 15 MAGNETIC SAFETY SWITCHES MAGNUS MG APPROVALS Safety Level •• •• •• •• •• •• •• •• PL e when connected to Mosaic Up to PL d when connected to MG d1 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” EN 61508-1:1998 “Functional safety of electrical/electronic programmable electronic safety related systems - General requirements” EN 61508-2:2000 “Functional safety of electrical/electronic/programmable electronic safety related systems Requirements for electrical/electronic/programmable electronic safety-related systems” EN 61508-3:1998 “Functional safety of electrical/electronic programmable electronic safety related systems: Software requirements” ISO 13849-1:2008 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” IEC 62061: “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” MECHANICAL DATA DIMENSIONS 36 Gaps (operating distance) for safe switching function in mm: 30 16 30 b SW 36 a Dimensions: mm 16 MINIMUM GAP normal with + magnet 0,5 3 ON normal with + magnet 4 7 a OFF normal with + magnet 16 18 b 5,5 28 M30X1,5 6 + = reinforced TYPE 3 SAFETY LASER SCANNER PHARO MAIN FEATURES Model PHR 332 Protective (safety) fields 2 programmable The Pharo Safety Laser Scanner is an optoelectronic protection device for accident prevention. Pharo is suitable for the protection of personnel exposed to risks deriving from both machines and systems with dangerous organs as well as from possible collisions with automatic guided vehicles (AGVs). With the Pharo Safety Laser Scanner it is possible to create programmable protected horizontal or vertical areas of variable shape suitable to all applications without the need to use a separate reflector or receiver. The device does not require an external control unit because all the safety functions are built-in. Warning zones 2 programmable Scanning area 190° / 4 m radius Programming by means - graphic user interface - teach-in - data transfer from file (from PC or from another laser scanner). Resolution Configurable from 30 mm to 150 mm from hand detection to access control Configuration Memory Module Yes for easy re-installation Configuration Software via RS 232 serial port Diagnostic Detailed self-diagnosis via display and remote serial output Start/restart interlock Built-in start/restart interlock, selectable EDM Feedback input for control of external relays (EDM) Operating temperature: -10 ... +50 °C -10 ... +50 ºC IP65 IP65 protection rating IP67 The Pharo Safety Laser Scanner features a Configuration Memory Module built into the removable connector, which stores the data related to the protected zones programmed and to the operating parameters set. This module enables the user to replace a faulty sensor with a new device without the need for reconfiguration and therefore maintaining the pre-existing configuration, without the possibility of errors or tampering. The stored data can only be modified by authorised personnel. Each sensor can create 2 independently programmable controlled zones: ■■ 2 safety zones with maximum radius of 4 metres ■■ 2 warning zones with maximum radius of 20 metres 17 TYPE 3 SAFETY LASER SCANNER PHARO APPROVALS •• •• •• •• •• •• •• •• •• •• •• •• •• •• SAFETY LEVEL TYPE 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” EN 61496-1:2004/A1:2008 “Safety of machinery - Electro sensitive protective equipment - General requirements and tests” IEC 61496-3:2008 "Safety of machinery - Electro-sensitive protective equipment - Particular requirements for Opto-electronic protective device responsive to diffuse reflection EN 62061:2005 “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” EN ISO 13849-1:2008 + AC:2009 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” IEC 61508 parts 1-7:1998/2000 "Functional safety of electrical/electronic programmable electronic safety related systems" EN 50178:1997 “Electronic equipment for use in power installations” EN 60204-1:2006/A1:2009 "Safety of machinery - Electrical equipment of machines" EN 60950-1:2006/A1:2010 "Information technology equipment - Safety" UL (C+US) mark for USA and Canada ANSI B11.19:2003 ANSI/RIA R15.06:1999 3 SIL 2 - SILCL 2 PL d - Cat. 3 E S P E MECHANICAL DATA DIMENSIONS 13,5 M8x9 Optical windows section 53,2 35 63 55 77,5 27,8 65,2 155 93 160 18 211 185 78,5 23 TYPE 3 SAFETY LASER SCANNER PHARO TECHNICAL DATA PART NUMBERS Includes CD-ROM containing configuration software in English and Italian and multi-language instruction manual and CE declaration of conformity. Ordering code: 1350041 Light source Laser diode wavelength 905 nm Laser source class 1 - according to EN 60825-1 Scanning angle 190° Angular resolution 0,25° ... 0,50° Response time (ms) Configurable 60 or 120 (with 2 scans) Start/Restart Automatic - timed automatic - manual reset (selectable via software) Serial interface configuration RS 232 Serial interface data transmission RS 422 Configuration and operating parameter setting Via configuration software (UCS) Configuration Memory Module Built into the main connector Signalling Display indications in 7 segments and LEDs for self-diagnosis and sensor status Power supply (VDC) 24 -30% +20% External relay control Feedback input with enabling, selectable Main connection Connector with screw terminals (13 poles cable) Serial interface connection for configuration Cable pre-wired with 2 connectors: M8 4-pole / subD 9-pole Electrical connections Max. cable length 30 m, cross-section 0.5 mm² SAFETY ZONE Max. range (m) 4 Resolution (mm) 30, 40, 50, 70, 150 configurable Min. target reflectivity 1,8% Safety outputs 2 PNP self-testing - 500 mA at 24 VDC WARNING ZONE Max. range (m) 20 (for objects with 20% reflectivity) Resolution (mm) Depending on the distance of the obstacle Min. target reflectivity 20% at 20 m Signalling outputs 1 PNP - 200 mA at 24 VDC 19 TYPE 3 SAFETY LASER SCANNER PHARO ACCESSORIES The following accessories are available for Pharo, to be ordered separately: Model Codes Description 30 poles connector pre-wired with 13-wire cable 5 m long PHR C3L5 1350061 PHR CSL2 1350070 PHR B3 1350050 fixed attachment bracket PHR B4 1350051 adjustable attachment bracket PHR B5 1350052 floor mounting bracket Floor mounting bracket PHR B5 Fixed bracket PHR B3 Built-in Configuration Memory Module Cable for serial connection between Pharo sensor and PC for configuring M8 4-pole / subD 9-pole connector, length 2 m Adjustable bracket PHR B4 Installation taps M8x9 WARNING! For the main connection of the Pharo laser scanner, it is necessary to provide a 13-wire cable with 0.56 mm2 crosssection. This cable is supplied with the PHR C3L5 main connector. To use the PHR B4 adjustable bracket it is also necessary to order the PHR B3 fixed bracket. To use the PHR B5 floor mounting bracket it is also necessary to order the PHR B3 fixed bracket and the PHR B4 adjustable bracket. 20 TYPE 2 SINGLE-BEAM SAFETY PHOTOCELLS ILION TECHNICAL FEATURES Minimum detectable object (mm) 12 Max. range (m) 8 IL 10 20 IL 20 1 ... 4 with AU SX and AU SXM control units Number of photocells per control unit Ilion is a Type 2 safety photocell with M18 cylindrical metal body. The photocells must be connected to control unit for esample: AU SX or AU SXM control unit with Muting to form a protection system that can be composed of 1, 2, 3 or 4 single beam photocells or Mosaic. In case of connection with Mosaic safety controller, the number of photocells depends to the configuration of the protection system (for details on the interface see AU SX, AU SXM and Mosaic control units). The compact size of the photocells makes it possible to fit the protection system into very small spaces, while the possibility to use more photocells provides the maximum flexibility in positioning the protective beams. All connections through M12 4-pole connectors. Unshielded cables up to 50 meter long (between sensor and control unit). In case of the Mosaic safety controller the number of photocells depends to the number available input related to the system configuration Response time for each photocell (ms) 7 Output PNP - 100 mA Signalling Status led Power supply (VDC) 24 ± 20% Electrical connections M12 4-pole Dimensions (mm) Ø 18 x 85 PART NUMBERS Ilion photocell includes multi-language instruction manual and CE declaration of conformity. IL 10 ordering code: 1200201 IL 20 ordering code: 1200202 CABLES NEEDED M12 5-pole. Pin 5 not connected See page 32 (CDx, CD 9x, CDM 9”, CDM 99) Operating temperature: 0 ... +55 °C 0 ... +55 ºC ACCESSORIES ■■ Safety interface AU SX. See page 29 ■■ Safety interface AU SXM. See page 30 IP65 IP67 IP67 protection rating ■■ Adjustable fixing Bracket. See page 38 21 TYPE 2 SINGLE-BEAM SAFETY PHOTOCELLS ILION APPROVALS SAFETY LEVEL TYPE Safety level (with a control unit AU XS, AU SXM or Mosaic): Type 2 – SIL CL 1 – PL c – Cat. 2 •• •• •• •• •• 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” IEC 61496-1 (ed.3) “Safety of machinery - Electro sensitive protective equipment - General requirements and tests” IEC 61496-2 (ed.3) “Safety of machinery - Electro-sensitive protective equipment - Particular requirements for equipment using active opto-electronic protective devices (AOPDs)" ISO 13849-1:2006 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” IEC 62061 (ed.1) “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” EN 50178:1997 “Electronic equipment for use in power installations” EN 55022:2110 “Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement” •• •• •• •• SILCL 1 PL c - Cat. 2 MECHANICAL DATA DIMENSIONS 86 9 M18 M12 60 43 22 2 Dimensions: mm TYPE 2 SINGLE-BEAM SAFETY PHOTOCELLS ULISSE TECHNICAL FEATURES Ulisse is a Type 2 safety photocell with metal body and M8 3-pole connector. The photocells must be connected to control unit for esample: standard AU SX or AU SXM control unit with Muting or Mosaic to form a protection system that can be composed of 1, 2, 3 or 4 single beam photocells. In case of connection with Mosaic safety controller, the number of photocells depends to the configuration of the protection system (for details on the interface see AU SX, AU SXM and Mosaic control units). Thanks to the very small size, the anodised aluminium case and the glass lenses free from electrostatic dust attraction, Ulisse is the ideal solution for the protection of weaving machines as well as of other applications characterised by high levels of mechanical stress or very restricted spaces. Minimum detectable object (mm) 8 Max. range (m) 6 Number of photocells per control unit 1 ... 4 In case of the Mosaic safety controller the number of photocells depends to the number available input related to the system configuration Response time for each photocell (ms) 7 Output PNP - 100 mA Signalling Status led Power supply (VDC) 24 ± 20% Electrical connections M8 3-pole Max. cable length (m) 50 (between sensor and control unit) Dimensions h x w x d (mm) 58 x 15 x 25 PART NUMBERS Ulisse photocell includes multi-language instruction manual and CE declaration of conformity. UPC ordering code: 1200300 CABLES NEEDED M8 3-pole. See page 33 (C 8x, C 895) Operating temperature: 0 ... +55 °C 0 ... +55 ºC IP67 protection rating IP65 ACCESSORIES ■■ Safety interface AU SX. See page 29 ■■ Safety interface AU SXM. See page 30 IP67 23 TYPE 2 SINGLE-BEAM SAFETY PHOTOCELLS ULISSE APPROVALS SAFETY LEVEL Safety level (with a control unit AU XS, AU SXM or Mosaic): Type 2 – SIL CL 1 – PL c – Cat. 2 •• •• •• •• •• •• •• •• •• 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” IEC 61496-1 (ed.3) “Safety of machinery - Electro sensitive protective equipment - General requirements and tests” IEC 61496-2 (ed.3) “Safety of machinery - Electro-sensitive protective equipment - Particular requirements for equipment using active opto-electronic protective devices (AOPDs)" ISO 13849-1:2006 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” IEC 62061 (ed.1) “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” EN 50178:1997 “Electronic equipment for use in power installations” EN 55022:2110 “Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement” MECHANICAL DATA DIMENSIONS = = 10 15 = 18 ,5 62,7 28,5 56 20,6 A4 = 8 25 Dimensions: mm 24 TYPE 2 SILCL 1 PL c - Cat. 2 SAFETY SWITCH WITH GUARD LOCKING SAFELOCK TECHNICAL FEATURES Housing material Reinforced thermoplastic Contact material Silver alloy, gold flashed Switching principle Slow-action switching contact Number of door position positively driven contacts 2 Number of guard lock monitoring positively driven 1 contacts Safelock is a safety switch utilised in the protection of personnel when opening doors leading to dangerous areas. It acts by monitoring and interrupting the safety circuit during dangerous scenarios. Approach speed Max. 20 m/min Actuation frequency 1200 1/h Guard locking principle Closed-circuit current principle Locking force (Fmax): ≥1 kN (plastic), ≥2 kN (metal) Force Retention force: 20 N The solenoid locks and unlocks access to the dangerous area, guaranteeing safety until the danger has stopped. Available models SLK-M Retention mechanism actuated by a spring and unlocked by ON current. Guard locking by spring force, release by applying voltage to the guard locking solenoid. Locking force (FZh): 1,5 kN 0,7 kN (plastic), 1,5 kN (metal) Extraction force: 30 N Actuating force: 35 N Solenoid operating voltage AC/DC 24 V -15% ... +10% Short circuit protection 4A Switching voltage 12 V Min at 10 mA Switching current 1 mA Min at 24 V Power consumption 6W SLK-E Retention mechanism actuated by ON current and unlocked by spring. Guard locking by applying voltage to the guard locking solenoid, release by spring force. ■■ Actuating head made of plastic or metal ■■ Auxiliary release on the front. Used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer ■■ Approach direction: horizontal and vertical. Can be adjusted in 90° steps ■■ Any installation position APPROVALS •• 2006/42/EC: “Machine Directive” •• EN 60947-5-1:2004/A1:2009 Low-voltage switchgear and controlgear. Control/circuit devices and switching elements. Electromechanical control circuit devices •• EN 60947-5-1:2004/A1:2009 Annex K •• EN ISO 14119:2013 Safety of machinery - Interlocking devices associated with guards - Principles for design and selection Operating temperature: -20 ... +55 °C -20 ... + 55 ºC IP67 protection rating IP65 IP67 25 SAFETY SWITCH WITH GUARD LOCKING SAFELOCK PART NUMBERS Ordering codes Models 1290100 SLK-M-P-2NC-24 1290101 SLK-M-P-NCNO-24 1290102 SLK-M-M-2NC-24 1290103 SLK-M-M-NCNO-24 1290104 SLK-E-P-2NC-24 1290105 SLK-E-P-NCNO-24 1290106 SLK-E-M-2NC-24 1290107 SLK-E-M-NCNO-24 Guard lock Mechanical Elecrtrical Description Safelock with mechanical guard lock and plastic actuating head. Switching element: 2 NC, feedback 1 NC Safelock with mechanical guard lock and plastic actuating head. Switching element: 1 NC + 1 NO, feedback 1 NC Safelock with mechanical guard lock and metal actuating head. Switching element: 2 NC, feedback 1 NC Safelock with mechanical guard lock and metal actuating head. Switching element: 1 NC + 1 NO, feedback 1 NC Safelock with electrical guard lock and plastic actuating head. Switching element: 2 NC, feedback 1 NC Safelock with electrical guard lock and plastic actuating head. Switching element: 1 NC + 1 NO, feedback 1 NC Safelock with electrical guard lock and metal actuating head. Switching element: 2 NC, feedback 1 NC Safelock with electrical guard lock and metal actuating head. Switching element: 1 NC + 1 NO, feedback 1 NC BLOCK DIAGRAM 22 A 21 24 21 23 22 A 12 11 11 11 12 12 23 24 12 11 12 12 11 11 11 12 B 11 12 B E1 E1 E2 E2 2NC Model For monitoring the guard locking (built-in solenoid) slow-action switching contact 2 NC NC NO Model For monitoring the guard locking (built-in solenoid) slow-action switching contact 1 NC +1 NA LIVELLI DI SICUREZZA 3 different safety functions according to the standard EN ISO 13489-1 Category / Safety Level Safety device Cat. 1 / PL c 1 Safelock + 1 safety relay AD SRE3C or 1 input of the Mosiac safety controller 1 Safelock + 1 safety relay AD SRE3C or 2 inputs of the Mosiac safety controller + fault exclusion according to the standard (EN ISO 13849-2) Cat. 3 / PL d 1 Safelock + 2 Magnus RFID + safety relay AD SR1 or 2 inputs of the Mosiac safety controller 2 Safelock + 1 safety relay AD SRE3C or 2 inputs of the Mosiac safety controller Cat. 4 / PL e 26 2 Safelock + 2 safety relay AD SRE4C or 4 inputs of the Mosiac safety controller SAFETY SWITCH WITH GUARD LOCKING SAFELOCK ACTUATORS Model Ordering codes Description ACT-S-S-RB 1290302 Actuator standard, straight with rubber bush Two stainless safety screws per actuator Actuators with rubber bushings ACT-S-A-RB 1290303 Actuator standard, angled with rubber bush Two stainless safety screws per actuator ACT-S-H-TB 1290304 Actuator standard, hinged, top-botton Actuators made of stainless steel Two stainless safety screws per actuator For doors hinged at top and bottom ACT-S-H-LR 1290305 Actuator standard, hinged, left-right Actuators made of stainless steel Two stainless safety screws per actuator For doors hinged on right and left ACT-F-S-RB 1290306 Actuator for insertion funnels, straight with rubber bush Two stainless safety screws per actuator Actuators with rubber bushings ACT-F-A-RB 1290307 Actuator for insertion funnels, angled with rubber bush Two stainless safety screws per actuator Actuators with rubber bushings ACT-F-H-TB 1290308 Actuator for insertion funnels, hinged, top-botton Actuators made of stainless steel Two stainless safety screws per actuator For doors hinged at top and bottom ACT-FH-LR 1290309 Actuator for insertion funnels, hinged, left-right Actuators made of stainless steel Two stainless safety screws per actuator For doors hinged on right and left ACT-F-IF 1292426 Insertion funnel CG M20 1290310 Cable glands 27 SAFETY SWITCH WITH GUARD LOCKING SAFELOCK MECHANICAL DATA DIMENSIONS M = 0,6 Nm Ø 4,2 h Ø 42 36 4 31 2,5 7 4, 96 31,5 2 Ø 5, 21 15,5 22 M=0,5 Nm 37,5 79 10,5 15,5 9 4 16 20,5 M20x1,5 Dimensions: mm 28 ACCESSORIES INTERFACES AU SX TYPE 2 CONTROL UNIT FOR ILION AND ULISSE PHOTOCELLS TECHNICAL FEATURES Control unit for safety photocells Ilion and Ulisse, which can be combined to form a Type 2 safety system. Up to 4 photocells may be connected. With guided-contact safety relays. Start/Restart interlock. EDM Feedback monitoring. input for external Safety relay outputs 2 NO - 2 A 250 VAC Status output PNP - 100 mA at 24 VDC Response time (ms) ≤ 30 Start/Restart command according to IEC 61496-1 Manual or automatic Start/Restart selectable on terminal block Signalling LED indication of input/output status and diagnosis Power supply (VDC) 24 ± 20% Electrical connections On terminal block Operating temperature (°C) 0 ... 55 Protection rating IP20 for housing IP2X for terminal block Fastening DIN rail fastening according to EN 50022-35 standard Dimensions h x w x d (mm) 99 x 22,5 x 114 contactors Self test every 5 seconds. APPROVALS •• •• •• •• •• •• •• •• •• 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive" 2014/35/EU: “Low Voltage Directive” EN 61496-1:2013 “Safety of machinery - Electro sensitive protective equipment - General requirements and tests” IEC 62061 (ed.1) “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” EN ISO 13849-1:2008 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” EN 50178:1997 “Electronic equipment for use in power installations” EN 55022:2010 “Information Technology Equipment- Radio Disturbance Characteristics - Limits and Methods of Measurement” UL (C+US) mark for USA and Canada PART NUMBERS AU SX module includes multi-language instruction manual and CE declaration of conformity. Ordering code: 1201710 SAFETY LEVEL TYPE 2 SILCL 1 PL c - Cat. 2 E S P E 29 ACCESSORIES INTERFACES AU SXM TYPE 2 CONTROL UNIT WITH INTEGRATED MUTING FOR ILION AND ULISSE PHOTOCELLS TECHNICAL FEATURES Inputs for Muting sensors 2 inputs 0 or 24 VDC – PNP or relay – dark-on Muting Enable input 0 or 24 VDC – PNP or relay Safety relay outputs 2 NO - 2A 250 VAC Status output PNP - 100 mA at 24 VDC Muting lamp output 24 VDC; 0,5 - 5 W Muting time-out 30 sec. or infinite, selectable With guided-contact safety relays. Override 2 operating modes selectable: manual action with hold to run or automatic with pulse command Muting time-out selectable. Override time-out (min) 15 Start/Restart interlock. Response time (ms) ≤ 30 EDM Feedback input for extra external contactors monitoring. Start/Restart command according to IEC 61496-1 Manual or automatic Start/Restart selectable on terminal block Self test every 5 seconds. Signalling LED indications of input/output status, Muting sensor inputs, diagnosis Power supply (VDC) 24 ± 20% Electrical connections On terminal blocks Operating temperature (°C) 0 ... 55 Protection rating IP20 for housing IP2X for terminal blocks Fastening DIN rail fastening according to EN 50022-35 standard Dimensions h x w x d (mm) 99 x 35 x 114 AU SXM control unit, with integrated Muting functions, for safety photocells Ilion and Ulisse, which can be combined to form a Type 2 safety system. Up to 4 photocells may be connected. 2-sensor Muting logics. APPROVALS •• •• •• •• •• •• •• •• •• 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” EN 61496-1:2013 “Safety of machinery - Electro sensitive protective equipment - General requirements and tests” IEC 62061 (ed.1) “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” EN ISO 13849-1:2008 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” EN 50178:1997 “Electronic equipment for use in power installations” EN 55022:2010 “Information Technology Equipment- Radio Disturbance Characteristics - Limits and Methods of Measurement” UL (C+US) mark for USA and Canada PART NUMBERS AU SXM module includes multi-language instruction manual and CE declaration of conformity. Ordering code: 1201711 SAFETY LEVEL TYPE 2 SILCL 1 PL c - Cat. 2 E S P E 30 ACCESSORIES INTERFACES MG d1 PL D CONTROL UNIT FOR MAGNUS MAGNETIC SWITCHES TECHNICAL FEATURES Safety relay outputs 2 NO - 3 A - 250 VAC Each NO safety output line is interrupted twice by the two relays Response time (ms) < 20 External Device Monitoring Yes Signalling LED indicators for status and diagnostic With 1 safety switch connected, a PL d safety level is reached. Power supply (VDC) 24 (±10%) Electrical connection On terminal block It features a two positively mechanically linked contacts and EDM (External Device Monitoring). Operating temperature (°C) 0 ... 55 Protection rating IP40 for housing IP2X for terminal block Fastening DIN rail fastening according to EN 50022-35 standard Dimensions h x w x d (mm) 75 x 25 x 94 MG d1 is a safety control unit for monitoring up to 8 Magnus safety switches in series. APPROVALS •• •• •• •• •• •• •• •• 2006/42/EC: “Machine Directive” 2014/30/EU: “Electromagnetic Compatibility Directive” 2014/35/EU: “Low Voltage Directive” EN 61508-1:1998 “Functional safety of electrical/electronic programmable electronic safety related systems - General requirements” EN 61508-2:2000 “Functional safety of electrical/electronic/ programmable electronic safety related systems Requirements for electrical/electronic/programmable electronic safety-related systems” EN 61508-3:1998 “Functional safety of electrical/electronic programmable electronic safety related systems: Software requirements” ISO 13849-1:2008 “Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design” IEC 62061: “Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems” MG d1 module includes multi-language instruction manual and CE declaration of conformity. PART NUMBERS Ordering code: 1291050 31 ACCESSORIES CABLES 2 1 Ø 14,5 CD x M 12x1 M12 STRAIGHT CONNECTOR 5-POLE 3 5 46 4 Models Codes Description CD 5 1330950 Pre-wired cable 5 m CD 10 1330956 Pre-wired cable 10 m CD 15 1330952 Pre-wired cable 15 m CD 20 1330957 Pre-wired cable 20 m CD 25 1330949 Pre-wired cable 25 m CD 50 1330965 Pre-wired cable 50 m 1 - Brown Note - Pin 5 not connected 2 - White 3 - Blue 4 - Black 5 - Grey 12 CD 9x M 12x1 M12 90° ANGLE CONNECTOR 5-POLE 35,5 Ø 14,5 26 Ø 4,5 3 2 1 - Brown 2 - White 3 - Blue 4 - Black 5 - Grey 32 Codes Description CD 95 1330951 Pre-wired cable 5 m CD 910 1330958 Pre-wired cable 10 m CD 915 1330953 Pre-wired cable 15 m Note - Pin 5 not connected 5 4 1 Models ACCESSORIES CABLES CDM 9 Ø 20 M12 STRAIGHT CONNECTOR 5-POLE SCREW TERMINAL, PG9 CABLE GLAND M 12x1 Model Code ≈ 60 CDM 9 1330954 30,5 CDM 99 35 M12 STRAIGHT CONNECTOR 5-POLE SCREW TERMINAL, PG9 CABLE GLAND Model Code CDM 99 1330955 M 12x1 Ø 20 Ø 10,2 CABLES C 8X M8 33 M8 STRAIGHT CONNECTOR 3-POLE 1 Model Codes Description C 85 1200217 Pre-wired cable 5 m C 815 1200219 Pre-wired cable 15 m 1 - Marrone 2 - Nero 3 - Blu 2 3 33 ACCESSORIES CABLES C 895 M8 90° ANGLE CONNECTOR 3-POLE 27 8,5 1 Code Description C 895 1200217 Pre-wired cable 5 m 3 16,5 2 Model 1 - Brown 2 - Black Ø 4,5 M8 3 - Blue Ø 10,5 C8 Gx Ø 10 M8 STRAIGHT CONNECTOR 4-POLE M8 30 2 1 4 1 - Brown Ø 4,5 2 - White 3 - Blue 4 - Black 34 3 Model Codes Description C8 G3 1291070 Pre-wired cable 3 m C8 G5 1291072 Pre-wired cable 5 m ACCESSORIES CABLES C8 G9x 27 M8 90° ANGLE CONNECTOR 4-POLE 4 8,5 1 Ø 4,5 2 Model Codes Description C8 G93 1291071 Pre-wired cable 3 m C8 G95 1291073 Pre-wired cable 5 m 16,5 3 1 - Brown 2 - White M8 Ø 10,5 3 - Blue 4 - Black 35 ACCESSORIES CABLES 1 EC S4 x 7 6 8 5 2 3 1 - Brown 2 - White 4 MALE-FEMALE M12 STRAIGHT CONNECTOR 4-POLE Model Codes Description MRFID EC S4 1 1292414 Pre-wired cable 1 m MRFID EC S4 3 1292415 Pre-wired cable 3 m MRFID EC S4 5 1292416 Pre-wired cable 5 m 3 - Blue 4 - Black MRFID EC S4 10 1292417 Pre-wired cable 10 m 5 - Grey 6 - Pink 7 - Violet 8 - Orange EC S8 x MALE-FEMALE M12 STRAIGHT CONNECTOR 8-POLE Model Codes Description MRFID EC S8 1 1292422 Pre-wired cablee 1 m MRFID EC S8 3 1292423 Pre-wired cable 3 m MRFID EC S8 5 1292424 Pre-wired cable 5 m MRFID EC S8 10 1292425 1 - Brown 2 - White 3 - Blue 4 - Black EC L4 x MALE-FEMALE M12 90° ANGLE CONNECTOR 4-POLE Model Codes Description MRFID EC L4 1 1292418 Pre-wired cable 1 m MRFID EC L4 3 1292419 Pre-wired cable 3 m MRFID EC L4 5 1292420 Pre-wired cable 5 m MRFID EC L4 10 1292421 36 Pre-wired cable 10 m Pre-wired cable 10 m ACCESSORIES CABLES 1 EC C4 x 7 6 8 FEMALE M12 STRAIGHT CONNECTOR 4-POLE 5 2 Model Codes Description MRFID EC C4 1 1292406 Pre-wired cable 1 m 2 - White MRFID EC C4 3 1292407 Pre-wired cable 3 m 3 - Blue MRFID EC C4 5 1292408 Pre-wired cable 5 m 4 - Bleck MRFID EC C4 10 1292409 3 4 1 - Brown Pre-wired cable 10 m 5 - Grey EC C8 x 6 - Pink 7 - Violet FEMALE M12 STRAIGHT CONNECTOR 8-POLE 8 - Orange Model Codes Description MRFID EC C8 1 1292410 Pre-wired cable 1 m MRFID EC C8 3 1292411 Pre-wired cable 3 m MRFID EC C8 5 1292412 Pre-wired cable 5 m MRFID EC C8 10 1292413 8 8 8 2 A B C 4 4 4 3 T CONNECTOR M12 T ADAPTER 4 Type A To gain status output from the connected sensor Type B For series connections of 2 or more sensors Type C To introduce additional power supplies in long series M RFID TP Termination plug Pre-wired cable 10 m Model Codes Description MRFID TC A 1292403 M12 T type A connector MRFID TC B 1292404 M12 T type B connector MRFID TC C 1292405 M12 T type C connector M RFID EC L 4 1 M RFID EC L 4 3 M RFID EC L 4 5 M RFID EC L 4 10 M RFID EC L 4 1 M RFID EC L 4 3 M RFID EC L 4 5 M RFID EC L 4 10 TP TERMINATION PLUG 4 4 4 4 Type B 8 Male - Female Model M12 connector (90°) MRFID TP Lenght: 1, 3, 5, 10 m Poles: 4 M RFID TC B Series connection 8 Code Description 1292402 Termination plug 4 4 3 4 Type C 2 Male - Female M12 connector (90°) Lenght: 1, 3, 5, 10 m Poles: 4 M RFID TC C Additional power supply 4 M RFID EC S 8 1 M RFID EC S 8 3 M RFID EC S 8 5 M RFID EC S 4 1 M RFID EC S 4 3 M RFID EC S 4 5 37 ACCESSORIES BRACKETS IL FB ADJUSTABLE FIXING BRACKET PARTS NUMBERS The IL FB bracket allows both vertical and horizontal adjustment of the optical axis of the photocell. 38 Model Code Description IL FB 1200090 Set of 2 adjustable brackets CUSTOMER SERVICE At ReeR we put our Customers always first ReeR after sales service is committed to support all customers that need technical guidance regarding functionality, handling and installation of our products. Customer Service Hotline +39 011 24 82 215 Monday to Friday 8.30 -12.30 and 13.30-18.00 (CET) or contact aftersales@reer.it For product returns please visit www.reersafety.com for further information. 39 Safety. Detection. Control. ReeR SpA Via Carcano, 32 10153 Torino Italy T +39 011 248 2215 F +39 011 859 867 www.reersafety.com | info@reer.it More than 50 years of quality and innovation Founded in Turin (Italy) in 1959, ReeR distinguished itself for its strong commitment to innovation and technology. A steady growth throughout the years allowed ReeR to become a point of reference in the safety automation industry at a worldwide level. The Safety Division is in fact today a world leader in the development and manufacturing of safety optoelectronic sensors and controllers. ReeR is ISO 9001, ISO 14001 and BS OHSAS 18001 certified. Made in Italy since 1959 Issue 1 Rev. 0.2 March 2017 8946228 Printed in Italy Safety Sensor Catalogue English ReeR SpA does not guarantee that product information in this catalogue are the most current available.ReeR SpA reserves the right to make changes to the products described without notice and assumes no liability as a result of their use or application. Our goal is to keep the information on this catalogue timely and accurate, however ReeR SpA accepts no responsibility or liability whatsoever with regard to the information on this catalogue. Reproduction is not authorised, except with the expressed permission of ReeR SpA.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Language : it-IT XMP Toolkit : Adobe XMP Core 5.6-c137 79.159768, 2016/08/11-13:24:42 Create Date : 2017:02:22 10:33:27+01:00 Metadata Date : 2017:02:22 10:34:03+01:00 Modify Date : 2017:02:22 10:34:03+01:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:e9278a5a-f4e4-43c2-b5c5-400abc8f34b6 Original Document ID : xmp.did:76b9a0cc-d628-c44f-97f9-a76c3e645123 Document ID : xmp.id:cb2b1b1d-20e6-6a40-8a09-abd6126f74ed Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:891471aa-6615-2c47-998d-96d4680b508b Derived From Document ID : xmp.did:891471aa-6615-2c47-998d-96d4680b508b Derived From Original Document ID: xmp.did:76b9a0cc-d628-c44f-97f9-a76c3e645123 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:02:22 10:33:27+01:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 40 Creator : Adobe InDesign CC 2017 (Windows)EXIF Metadata provided by EXIF.tools