Fluke Electronics FLK1750 Power Recorder User Manual 0master

Fluke Electronics Power Recorder 0master

Users Manual

Download: Fluke Electronics FLK1750 Power Recorder User Manual 0master
Mirror Download [FCC.gov]Fluke Electronics FLK1750 Power Recorder User Manual 0master
Document ID705309
Application IDkxEhywrQp21hvjs8HsoR3A==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize81.55kB (1019342 bits)
Date Submitted2006-09-15 00:00:00
Date Available2006-09-21 00:00:00
Creation Date2006-08-04 13:31:43
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2006-08-04 13:34:16
Document TitleMicrosoft Word - 0master.doc
Document CreatorPScript5.dll Version 5.2.2

1750
Power Recorder
Operators Manual
September 2006
© 2006 Fluke Corporation, All rights reserved.
All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under normal use and
service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and
services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of
a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in
Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that software will operate substantially in accordance
with its functional specifications for 90 days and that it has been properly recorded on non-defective media.
Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers
only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is
available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right to invoice Buyer for importation costs of
repair/replacement parts when product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair,
or replacement of a defective product which is returned to a Fluke authorized service center within the
warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that service center, with a description of the difficulty,
postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal
condition of operation or handling, including overvoltage failures caused by use outside the product’s
specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair
costs and obtain authorization before commencing the work. Following repair, the product will be returned to
the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges
(FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES,
INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other
provision.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
11/99
To register your product online, visit register.fluke.com
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
Table of Contents
Title
Introduction .......................................................................................................
Contacting Fluke ...............................................................................................
Safety Information ............................................................................................
Accessories........................................................................................................
Features .............................................................................................................
Applying the Front Panel Decal ........................................................................
Features .............................................................................................................
Charging the PDA Battery ................................................................................
Installing the Software ......................................................................................
Installing Power View on the PDA...............................................................
System Requirement for Power Analyze......................................................
Installing Power Analyze..............................................................................
Installing the Power Recorder at a Facility .......................................................
Work Flow ....................................................................................................
Installing the Recorder..................................................................................
Connecting the Recorder to the Wiring ........................................................
Verifying Your Connection ..........................................................................
Finishing UP .................................................................................................
Managing Recorded Data .............................................................................
Power Type Diagrams.......................................................................................
Communicating with the Recorder Using Power View ....................................
Navigating in Power View on the PDA ............................................................
Power View Menus.......................................................................................
Icons on the Menu Bar..................................................................................
Menu Tree .........................................................................................................
Home Screen .....................................................................................................
Finding Recorders Within Range..................................................................
Downloading Data and Erasing Memory..........................................................
Viewing Live Data ............................................................................................
Scope Screen.................................................................................................
Meter Screen .................................................................................................
Phasor Screen................................................................................................
Trend Screen .................................................................................................
Harmonics Screen .........................................................................................
Page
12
12
12
12
13
13
13
14
14
15
15
16
16
27
28
28
28
30
31
31
33
37
37
38
38
39
39
Viewing Phases.............................................................................................
Setting Up the Recorder ....................................................................................
Setting the Clock...........................................................................................
Probe Detect..................................................................................................
Setting the IP Address...................................................................................
Overwriting Nominal Power Values.............................................................
Assign Recorder Name and Password ..........................................................
Using Phase Swap.........................................................................................
Setting the Volts and Current Ratio ..............................................................
Setting the Snapshot Period - Periodic Waveform Capture Setting..............
Using Image or Voice Annotations...............................................................
Inserting Image or Voice Annotations..........................................................
Cleaning and Maintenance................................................................................
Regulatory Information for Wireless Communication......................................
Specifications for the System: Recorder and Power Analyze Software............
General Specifications ..................................................................................
Input Specifications ......................................................................................
Synchronization and Sampling .....................................................................
Voltage and Current Measurements..............................................................
Voltage and Current Measurement Accuracy...............................................
Transient Voltage (Impulse) .........................................................................
Dip (Sag) and Swell Measurements..............................................................
Power and PF Measurement .........................................................................
External Interface Specifications ..................................................................
Environmental and Safety Specifications .....................................................
ii
40
40
41
42
43
43
44
44
45
46
48
48
49
49
50
50
50
50
51
51
51
51
51
52
52
List of Tables
Table
1.
2.
3.
4.
Title
Symbols .................................................................................................................
Standard Accessories.............................................................................................
Input Terminals and Controls ................................................................................
Input Terminals and Controls ................................................................................
iii
Page
10
List of Figures
Figure
1.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Title
Fluke 1750 Power Recorder ..................................................................................
1750 Power Recorder ............................................................................................
Connecting the Supplemental Ground Terminal ...................................................
One Phase Plus Neutral .........................................................................................
One-Phase IT No Neutral ......................................................................................
One-Phase Split Phase...........................................................................................
Three-Phase Wye...................................................................................................
Three-Phase Delta .................................................................................................
Three-Phase IT ......................................................................................................
Three-Phase High Leg...........................................................................................
Three-Phase Open Leg ..........................................................................................
2-Element Delta.....................................................................................................
2 ½-Element Wye..................................................................................................
Connecting to the Recorder ...................................................................................
Power View Menu Tree.........................................................................................
Page
11
17
18
19
20
21
22
23
24
25
26
27
30
1750 Power Recorder
Operators Manual
Introduction
The Fluke 1750 Power Recorder is a comprehensive yet easy to use system for power
quality investigations. The 1750 Power Recorder, referred to hereafter as simply “the
Recorder”, consists of a power recorder instrument, a wireless handheld Personal Digital
Assistant (PDA) for control and setup, and a powerful yet easy to use PC application,
Power Analyze. Four 400 A current probes are provided as standard equipment. A wide
range of ferro and Rogowski (flexible) type current probes are available from Fluke.
Key features of the 1750 Power Recorder are:
•
No PC needed for setup
Using the included a wireless-enabled Personal Digital Assistant (PDA) as a controller,
you do not need a PC to configure the Recorder, troubleshoot connections, preview data,
or download the recorded data. The range of the PDA with the wireless link is about 15
meters (45 feet) from the Recorder.
•
Simplified test lead connections to the power network
Differential inputs are not required due to internal referencing from phase channel to
phase channel. This means you simply connect a voltage probe to a conductor on each
phase that you want to record. On the current inputs, there is an identification resistor in
the connector that the Recorder uses to determine which probe is attached. The Recorder
then configures its measurement system appropriately for the model of current probe you
are using.
•
Connection diagrams for the supported power network configurations (delta, Wye, and
others) appear on the handheld PDA controller. Once you make connections, you can
view live readings and a PHASOR diagram on the PDA to confirm the connections. If a
phase channel is wired incorrectly, you can swap the phase to another channel by
changing an internal Recorder software setting using the PDA, and then reconfirm correct
readings.
•
Internal Uninterruptible Power Supply (UPS)
An internal NiMH (Nickel-Metal-Hydride) battery pack and charging system maintain
data capture continuity through power interruptions of 5 minutes or less.
•
Automatic disturbance capture
The Recorder uses an automatic, self-learning threshold routine, which means you do not
have to set any event threshold limits before you start recording. You detect and display
power quality events (disturbances) using the Power Analyze software on a PC after the
event has been captured.
1750
Operators Manual
With these features, there is little else required to set up and start recording the data to
conduct a power quality survey. Should you want to extensively analyze collected data,
the procedures described later in this manual review the transfer of data from the
Recorder to the PDA, and finally to a PC. Data may then be analyzed using Power
Analyze on a PC. Extensive online help is provided in the Power Analyze software on the
product CD shipped with the Recorder.
Contacting Fluke
To contact Fluke, call:
1-888-993-5853 in USA
1-800-363-5853 in Canada
+31-402-675-200 in Europe
+81-3-3434-0181 in Japan
+65-738-5655 in Singapore
+1-425-446-5500 from anywhere in the world
Or, visit Fluke’s Web site at www.fluke.com
To register your product, visit register.fluke.com
Operators Manual
Safety Information
Safety Information
The Recorder complies with EN 61010-1 600 V, CAT IV, 1000 V CAT III overvoltage
rating. See the Specifications section for a full agency compliance list.
XWWarning
To avoid electrical shock or fire:
•
Review the entire manual before using the Recorder and its
accessories.
•
Avoid working alone.
•
Do not operate the Recorder around explosive gas or vapor.
•
Use only insulated current probes, test leads, and adapters as
supplied with the Recorder, or indicated as suitable for the
Recorder.
•
Before use, inspect the Recorder, voltage probes, current clamps,
leads, and accessories for mechanical damage, and replace when
damaged. Look for cracks or missing plastic. Pay special attention
to the insulation surrounding the connectors.
•
Remove all probes, test leads, and accessories that are not in use.
•
Make sure the Recorder is properly connected through the power
cord to protective earth ground.
•
Do not apply input voltages above the rating of the Recorder as
shown on the input panel.
•
Do not apply voltages in excess of the marked ratings of the voltage
probes and current clamps.
•
Do not use exposed metal BNC or banana plug connectors.
•
Do not insert metal objects into connectors.
•
Never open the Recorder’s enclosure, dangerous voltages are
present. There are no user replaceable parts in the Recorder. Refer
servicing of internal parts to qualified service personnel
•
Use the Recorder only as specified in this manual, or the protection
provided by the Recorder may be impaired.
1750
Operators Manual
Table 1. Symbols
Hazardous voltage. Risk of electrical
shock. Precedes Warning
Risk of danger. Important information. See
manual. Precedes Caution and Warning.
Conforms to requirements of European
Union and European Free Trade
Association (EFTA).
Do not dispose of this product as unsorted
municipal waste. Contact Fluke or a
qualified recycler for disposal.
Canadian Standards Association. [ Note:
Canadian and US. ]
Protective conductor terminal.
CAT III
CAT III equipment is designed to protect
against transients in equipment in fixedequipment installations, such as
distribution panels, feeders and short
branch circuits, and lighting systems in
large buildings.
CAT IV equipment is designed to protect
against transients from the primary supply
level, such as an electricity meter or an
CAT IV
overhead or underground utility service.
Operators Manual
Accessories
Accessories
Table 2 describes the standard accessories that ship with the Recorder.
Table 2. Standard Accessories
Description
Part Number
Ethernet cable, 3 meters, yellow
2402854
Colored plastic clips for test leads (32 clips, 8 colors, 4 clips each color)
2157607
Model TLS430, test lead set including cable and clips
2157713
512MB Secure Digital (SD) Memory Card for downloading data
2386744
Model 3140R, 400 A Clamps (3)
2277216
AC power cord, 3 meters
2441360
Personal Digital Assistant (PDA) with docking station
2386780
CD ROM Manuals and Software
2386771
1750 Getting Started Guide
2386767
Sheet of Front Panel Decals
2436261
Sets of international ac power adapters for both the PDA charger and the Recorder
2583479
International Adapters
2441372
You can also order the following optional accessories. For more information about
accessories, see Contacting Fluke earlier in this manual.
•
Soft Carry Bag
•
Hard Travel Case
•
Security Cable
•
Mounting Bracket
•
Replacement Ethernet Cable Kit
•
Various Current Probes
3601 Crocodile Clip
3602 Battery Clip
3605 Stud Type
3606 Screw Type
3607 Bus Bar
3608 Plunger Type
3641 In-Line Fuse
•
Replacement Voltage Lead Set
•
Clamp-on Current Transformers (3005R, 3014, 3120R, 3100R, 3300)
•
Flexible Current Transformers (3110, 3112, 3210, 3212, 3310, 3312)
•
Split-Core Current Transformers (3583R, 3584R, 3585R)
•
Interface and Extension Cables
3570 CT Cable
3533 Pod Adapter
1750
Operators Manual
Features
The Recorder front panel is illustrated in Figure 1 and described in Table 3.
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63Hz
ON
CURRENT
LINK
BUSY
13
12
11
10
azd09f.eps
Figure 1. Fluke 1750 Power Recorder
Operators Manual
Features
Table 3. Input Terminals and Controls
Number
Description
Standard 120/240 V 50/60 Hz power input for Recorder power
Voltage indicator
Steady
Voltage is present, not overloaded
Blinking
Voltage overload (overload threshold 1100 V)
Five voltage measurement inputs
Removable Secure Digital (SD) memory card for transfer of large quantities of data. You can
remove the card from the Recorder, insert in the PDA and transfer data to the PC via the
“synchronize data” feature of the PDA.
SD status indicator
Steady green
SD card inserted
Blinking
Busy - do not remove the card
Wireless Controller Status Indicator
Steady Blue
Wireless controller enabled but not
communicating
Blinking
Wireless controller communicating
Off
Disabled
Ethernet port. TCP/IP via Ethernet is used to connect the Recorder to a PC for downloading
recorded data, and for configuring the Recorder when not using the PDA.
Busy Indicator
Blinking
Network is busy
Link indicator
Off
Steady
Blinking
No link
Link Present
Communicating (with PDA or PC)
Current Measurement Terminals (5)
Current indicator
Steady
Current probe in normal range
Blinking
> 110% of probe range, use a higher range probe
Off
Current insufficient to measure
Red/Green LED
Steady green
Green/Red blinking
Blinking red
AC input power normal
Recording
Recorder running on UPS
Ground Terminal
Connecting the supplemental ground terminal and the line cord safety ground to different
ground potentials creates a ground loop that can damage the Recorder. To avoid this, use the
supplemental ground terminal only when no protective earth ground connection exists through
the line power cord. If there is any chance that a safety ground connection does exist through
the line power cord connection, make sure to connect the supplemental ground terminal only to
the ground system used by the ac receptacle that powers the Recorder. See Figure 4.
1750
Operators Manual
WCaution
Connecting the supplemental ground terminal and the line cord
safety ground to different ground potentials creates a ground
loop that can damage the Recorder.
Applying the Front Panel Decal
Self-adhesive front panel decals are supplied with the 1750. The supplied decals
correspond to the wiring color codes used in the USA, Europe and UK (new), Europe
(old), UK, Canada, and China. Apply the decal appropriate for your local wiring codes
around the current and voltage inputs as shown in Figure 2.
Figure 2. Applying the Front Panel Decal
Operators Manual
Features
Features
The Recorder features are illustrated in Figure 3 and described in Table 3.
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63Hz
ON
CURRENT
LINK
BUSY
13
12
11
10
azd09f.eps
Figure 3. 1750 Power Recorder
1750
Operators Manual
Table 4. Input Terminals and Controls
Number
Standard 120/240 V 50/60 Hz power input for Recorder power.
Voltage indicator
Steady
Voltage is present, not overloaded
Blinking
Voltage overload (overload threshold 1100 V)
Five voltage measurement inputs.
Removable Secure Digital (SD) memory card for the transfer of large quantities of data. You
can remove the card from the Recorder, insert it in the PDA and transfer data to the PC via the
synchronize data feature of the PDA.
SD status indicator
Steady green
SD card inserted
Blinking
Busy - do not remove the card.
Wireless Controller Status Indicator
Steady Blue
Wireless controller enabled but not communicating
Blinking
Wireless controller communicating
Off
Disabled
Ethernet connector for PC communication. TCP/IP over Ethernet is used to connect the
Recorder to a PC for downloading recorded data and for configuring the Recorder when not
using the PDA.
Busy Indicator
Blinking
Network is busy
Link indicator
Off
Steady
Blinking
No link
Link Present
Communicating
Current Measurement Terminals (5)
Current indicator
Steady
Current probe in normal range
Blinking
>110% of probe range, use a higher range probe
Off
Current insufficient to measure
Red/Green LED
Steady green
Green/Red blinking
Blinking red
10
Description
AC input power normal
Recording
Recorder running on UPS
Ground Terminal
Connecting the supplemental ground terminal and the line cord safety ground to different
ground potentials creates a ground loop that can damage the Recorder. To avoid this, use the
supplemental ground terminal only when no protective earth ground connection exists through
the line power cord. If there is any chance that a safety ground connection does exist through
the line power cord connection, make sure to connect the supplemental ground terminal only to
the ground system used by the ac receptacle that powers the Recorder. See Figure 4.
Operators Manual
Features
WCaution
Connecting the supplemental ground terminal and the line cord
safety ground to different ground potentials creates a ground
loop that can damage the Recorder.
azd11f.eps
Figure 4. Connecting the Supplemental Ground Terminal
11
1750
Operators Manual
Charging the PDA Battery
Your PDA is shipped with a partially charged, rechargeable battery. You should fully
charge the battery before setting up the device, and recharge it regularly. Refer to your
PDA user’s guide for detailed information about the battery.
WCaution
Do not leave important data on the PDA. If the battery
discharges completely, you will lose all data not stored in File
Store (ROM). Discharging the battery completely is similar to
performing a hard reset. Refer to the PDA user’s manual for
more information.
Installing the Software
This section describes how to install Fluke Power View software on the PDA and Fluke
Power Analyze software on your PC.
Installing Power View on the PDA
1. Insert in your PC the CD that ships with your PDA. Follow the
on-screen instructions to install the ActiveSynch software that allows your PC to
communicate with the PDA.
2. Put the PDA in the docking station and establish a partnership between the PDA
and your PC.
3. Insert the CD that ships with your Recorder in the CD-ROM drive on your PC.
4. A window appears that lists options on the CD. If the install software window
does not automatically appear, do the following:
5. On the Windows taskbar, select Start, then Run.
6. Type d:\loader.exe (where d: is your CD drive letter).
7. Select Install Software.
8. Select Install Fluke Power View.
9. Power View will be installed in the Programs folder on the PDA.
10. To start Power View select Start, and then Programs on the PDA. Tap the Power
View icon
to start using the application.
System Requirement for Power Analyze
• Windows Operating System
12
•
Windows 2000 Professional at minimum, Windows XP or higher recommended.
•
PC Hardware
•
PC with 300 MHz or higher processor clock speed, Intel Pentium/Celeron family,
or AMD Athlon/Duron family.
•
Processor Recommended: 1 GHz or higher, Pentium 4, AMD Athlon, or better.
•
256MB RAM (1GB recommended).
•
1024 x 768 or higher resolution video.
•
Keyboard and mouse.
Operators Manual
Installing the Power Recorder at a Facility
•
Administrator privileges are required to install software on Windows 2000 or XP.
Installing Power Analyze
Before installing the software on your PC, make sure you have Internet Explorer version
5.01, or later appropriate to the language or culture settings of the operating system
installed on your computer.
WCaution
Do not remove the CD until after you have successfully
installed the software, rebooted the machine, and opened the
application.
1. Insert the CD into your CD-ROM drive.
2. A window appears that lists options on the CD. If the window does not
automatically appear
3. On the Windows taskbar, select Start, then Run.
4. Type d:\loader.exe (where d: is your CD drive letter).
5. Select Install Software.
6. Select Install Fluke Power Analyze.
7. Follow the installation instructions that appear. After software installation is
appears on your desktop.
complete, the Power Analyze icon
8. Start Power Analyze on your PC by choosing Start > All Programs > Fluke >
Power Analyze > Launch Power Analyze or double-click the Power Analyze
on your desktop.
icon
9. After the installation is complete, please take a few minutes to complete your
product registration. You can register quickly online (preferred) at
http://register.fluke.com or you can print the form and fax it to the number
provided on the form. Product registration is very important since it allows you to
get free software updates and helps us provide you with the fastest and most
efficient technical support.
Installing the Power Recorder at a Facility
This section describes the steps you need to take to set up the Recorder at a facility and begin a
recording session.
Work Flow
There are three distinct stages for a recording session.
•
Set-up
Set-up, hookup, and verification of connections and measured signals. This is
when you will want to clear the Recorder memory, make any desired Recorder
setting changes, and insert annotations and/or an optional Start mark into the
recorded data stream. Annotations are messages or notes you insert into the data
stream during a recording session.
•
Interim checkup, mid-recording session
At this time, you may want to re-check all the live input signals, and download
the data recorded since the beginning of the recording session. Annotation
capability is always available during the recording session.
13
1750
Operators Manual
•
End of recording session
You can re-verify if desired, correctness of live data and then download data,
power off the Recorder, and pack up fir transport.
Installing the Recorder
To install the Recorder at a facility, follow the basic steps below.
1. Position the Recorder within 2.5 m (8 ft) of the monitoring location.
2. The Recorder can be set on the floor or a table, or attached and secured to a pole
or other mounting surface.
3. Connect the Recorder to a 100 to 240 V ac power source.
•
Connect the power cord to the Recorder using the appropriate supplied
adapter.
•
Connect the power cord to a properly grounded wall outlet.
WCaution
Be sure to plug the power cord into the Recorder panel
BEFORE connecting it to an outlet
4. Plug the power cord into a properly grounded wall outlet.
5. Turn on the PDA and tap the Power View icon
to launch Power View.
6. If a Recorder is within range and is not password protected, the Home screen for
live data appears.
7. If more than one Recorder is within range, select one Recorder for use.
8. If you have established password protection, you must type the correct password
in the Password text box and tap the Enter button. (Password protection is
established for a specific Recorder using either the Setup Password menu in
Power View or the Power Analyze software).
9. All LEDs should flash ON, then OFF, and then each should turn ON and OFF in
sequence. The LEDs will then remain on if you make a secure connection and
there is sufficient voltage and current.
Connecting the Recorder to the Wiring
After you have set up the Recorder you are ready to connect the clamps and probes to the
wiring. Refer to the Power Type diagrams provided on the PDA or in the 1750 Operators
Manual.
In most cases, you should install the current clamps first. Because they are clamped
around wires, current clamps are usually more secure than voltage probes. Examine the
conductors you are about to connect to and determine if you should attach the current
clamps to the phase wires before you connect the voltage probes.
1. Select and attach the appropriate current clamps to the Recorder.
2. Select and attach the appropriate voltage probes to the Recorder.
Note
If your power connections require potential transformers (PTs) or current
transformers (CTs), you can use the ratio settings in Power View to set the
Recorder to display readings as they exist on the primary side of the PT and
CT (for example, 12000 V).
14
Operators Manual
Installing the Power Recorder at a Facility
WCaution
Make sure the current clamps and voltage probes are paired
correctly. The leads for the current clamp and voltage probe of
the same color should be attached to the same phase wire or
busbar.
3. Connect the Recorder to the wiring by first connecting the ground probe to the
distribution system ground, and then the neutral probe to neutral.
4. With the ground clamp to the distribution system ground and the neutral clamp to
neutral connect the current clamps.
5. Connect the remaining current clamps.
•
The arrow on the clamp should point toward the load.
•
Use the color-coding on the leads to help you connect the probes to the
correct phases, neutral and ground.
6. Connect the remaining voltage probes.
Note
Make sure the voltage probes and current clamps are paired correctly.
Calculations are made in pairs and cannot be changed after data is
recorded. The leads for the voltage probe and current clamp of the same
color should be attached to the same phase wire or busbar.
7. Check the LED for each phase to make sure a connection is established.
•
When a phase LED is ON or lighted, you know that the connection is
active and that voltage and current is within the normal range.
•
When a phase LED is BLINKING, you are connected but the voltage or
current is exceeding the normal range or exceeding the range of the
probe that you are using.
•
When a current LED is OFF or unlit, there is insufficient current present
in the line.
Verifying Your Connection
Before you leave the Recorder to accumulate data at the facility, double-check the
connections.
•
Make sure the current clamps are secured and completely closed around the
conductors and that the voltage and current LEDs are steady-on.
•
Use the PHASOR screen on the PDA to verify that the voltage and current
connections are correct. You can swap the connections using Power View if they
are incorrect.
Finishing UP
After making any corrections to the connections, recheck the PHASOR diagrams to
confirm your connection. Make sure the nominal voltage, nominal line frequency, and
power type (delta, wye, other) are correct before you leave the Recorder. It is a good
practice to insert a Start Mark when you are finished with all settings so you can
download data and ignore useless readings and events common at the beginning probe
connecting activities.
15
1750
Operators Manual
Managing Recorded Data
Recorded data resides in the Recorder on an internal non-accessible flash memory circuit.
It is not transferred to an SD memory card in the Recorder’s SD memory slot until you
request a download action using the PDA or an attached PC.
It is never necessary to erase internal memory. When the Recorder has new data to
record, it does so automatically, overwriting the oldest data. You can erase internal
memory, if you want to simplify what you will be seeing in the download data screen.
The start and end times will represent one recording session when old data is erased.
Note
Data is not removed from internal Recorder memory until you erase it
using Power View software on the PDA or Power Analyze software on your
PC.
Power Type Diagrams
The wiring illustrations included cover the standard power configurations that are
selectable in Power View or Power Analyze software. The diagrams are provided as an
aid in making the correct test lead connections. Power type diagrams are also included on
your PDA and can be referenced when you are setting up nominal power on the
Recorder.
Available power type settings are:
16
•
One-Phase Plus Neutral
•
One-Phase IT No Neutral
•
One-Phase-Split Phase
•
Three-Phase Wye
•
Three-Phase Delta
•
Three-Phase IT
•
Three-Phase High Leg
•
Three-Phase Open Leg
•
2-Element Delta
•
2 ½-Element Wye
Operators Manual
Power Type Diagrams
ØA
Source
GND
GND
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63 Hz
ON
CURRENT
LINK
BUSY
azd02f.eps
Figure 5. One Phase Plus Neutral
Example: Branch circuit at an outlet.
17
1750
Operators Manual
GND
GND
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63Hz
ON
CURRENT
LINK
BUSY
azd14f.eps
Figure 6. One-Phase IT No Neutral
Example: Used in Norway and in some hospitals. This would be the connection at a
branch circuit.
18
Operators Manual
Power Type Diagrams
ØB
ØA
ØC
GND
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63Hz
ON
CURRENT
LINK
BUSY
azd03f.eps
Figure 7. One-Phase Split Phase
Example: A North American residential installation at the service entrance.
19
1750
Operators Manual
ØB
Source
ØC
ØA
GND
GND
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63 Hz
ON
CURRENT
LINK
BUSY
azd04f.eps
Figure 8. Three-Phase Wye
Example: Also called “Star” or four-wire connection. Typical commercial building
power.
20
Operators Manual
Power Type Diagrams
ØA
GND
GND
ØC
ØB
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63 Hz
ON
CURRENT
LINK
BUSY
azd05f.eps
Figure 9. Three-Phase Delta
Example: Often found in industrial settings where electric motors are used.
21
1750
Operators Manual
ØA
GND
GND
ØC
ØB
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63 Hz
ON
CURRENT
LINK
BUSY
azd12f.eps
Figure 10. Three-Phase IT
Example: Industrial power in countries that use the IT (Isolated Terra) system, such as
Norway.
22
Operators Manual
Power Type Diagrams
ØC
ØB
ØA
GND
GND
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63Hz
ON
CURRENT
LINK
BUSY
azd08f.eps
Figure 11. Three-Phase High Leg.
Example: A way to get a 120 V single phase feed by tapping across part of a leg in a delta
power system
23
1750
Operators Manual
ØC
ØB
ØA
GND
GND
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63Hz
ON
CURRENT
LINK
BUSY
azd06f.eps
Figure 12. Three-Phase Open Leg
Example: A variant of power transformer winding type.
24
Operators Manual
Power Type Diagrams
ØB
ØA
ØC
GND
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63Hz
ON
CURRENT
LINK
BUSY
azd13f.eps
Figure 13. 2-Element Delta
Example: Blondel or Aron connection, used to measure power like a two-element
revenue power meter.
25
1750
Operators Manual
ØA
GND
ØC
ØB
No Connection
1750 POWER RECORDER
VOLTAGE
SD
POWER
ETHERNET
100-240 V
47-63 Hz
ON
CURRENT
LINK
BUSY
azd07f.eps
Figure 14. 2 ½-Element Wye
Example: Blondel or Aron system for a 4-wire (Wye) power secondaries.
26
Operators Manual
Communicating with the Recorder Using Power View
Communicating with the Recorder Using Power View
The PDA serves as your control panel for the Recorder. The Power View software
installed on the PDA is designed to function as a remote front panel for the Recorder,
since the Recorder itself is a “black box” with no integral display or external controls
other than status LEDs. With Power View installed on the PDA, you are relieved of the
burden of having to carry a laptop and Ethernet cable to a remote site when setting up the
Recorder, checking its progress, or finishing a monitoring session.
You can alternatively connect to a Recorder from a PC directly using an Ethernet cable or
remotely over an IP network. You can then use Fluke Power Analyze to set up the
Recorder, view power measurements wherever the Recorder is installed, or download
data from the Recorder.
Power View communicates with the PDA using a wireless controller radio interface.
There is no provision for a hardwired PDA interface to the Ethernet port on the Recorder.
After data is recorded and downloaded to a PC, you can analyze the recorded data using
the Power Analyze software.
PDA with
Power View Software
SD Flash
Memory
Card
Configure via RF
Communication
PC with Power
Analyze Software
SD Flash
Memory
Card
Fluke 1750
Power Recorder
Direct Ethernet Connection
azd01f.eps
Figure 15. Connecting to the Recorder
27
1750
Operators Manual
Navigating in Power View on the PDA
The Menu Bar on the bottom of the Power View screen allows you to quickly and easily
configure a connected Recorder, view live data, and transfer data to the Secure Data (SD)
card for viewing and analysis on your desktop computer using the companion Power
Analyze software.
Power View Menus
Data
Brings up the memory management screens which are for download to the SD card
inserted in the Recorder and for erasing Recorder internal memory erasing and SD card
files.
View
Brings up a list of the live detail views: Scope, Meter, Phasor, Harmonics, and Trend.
There are configurable detail views of each type of screen available by tapping the sector
of interest or the View menu. Once a detail view is selected, navigation to all available
detail views is accomplished using the View menu.
Setup
Brings up the Recorder Setup menu, which allows you to configure the Recorder and set
recording period information. Using this function, you can tap the appropriate icon to set
the following :
•
Clock
•
Nominal Volts
Nominal voltage and frequency values are auto-detected by the Recorder and
shown as the defaults. These settings can be overwritten, forcing the Recorder to
change its internal configuration to optimize power quality data recording for
custom settings.
•
Volts and Current Scale
•
Passwords
•
Power Type Diagrams
•
Phase Swap
•
Probe Detect
Icons on the Menu Bar
Toggles between voltage and current waveforms. The PHASOR screen always shows
both V & I (volts and amps). This
icon is replaced with the
icon on the detail
views, as voltage and current data can be viewed simultaneously.
button at
In all the detail live view screens, a line selection menu is available using the
the bottom. This is a checkbox that is used to select the voltage and current channels you
want to display.
This icon triggers the Recorder to capture high-resolution waveform data and save it in
the recorded data stream. This waveform capture is identical to the “snapshot period”
which can set up to happen automatically in the Recorder Setup menu.
28
Operators Manual
Navigating in Power View on the PDA
This icon brings up the Annotate screen. Use the annotate menu to enter text or to insert a
file and load it into the recorded data stream in the Recorder. Annotations can be used to
make notes, or to insert an image or audio file name. You can enter multiple start and
stop annotations. Start and stop annotations are not paired and are not restricted to being
used as literally “start” and “stop”. Annotations are often done at the start of a power
recording session.
[keyboard]
This icon brings up the standard PDA data entry keyboard.
29
1750
Operators Manual
Menu Tree
The following figure provides an overview of the Power View menu structure that will be
helpful in navigating through the Power View application.
SD
Fluke
Power View
Fluke
Power View
1750
Password
Connecting
1750 Power Recorders
Found
1750 Power Recorder
Not Found
Delta
Incorrect Password
1750
Data
View
Setup
Home
1750 Internal Memory
Scope
Meter
Phasor
Harmonics
Trend
1750 SD Memory
Erase 1750 Memory
1750 Setup
Snapshot Interval
Setup
Download
Scope
Scope
If Memory is full
Meter
Delete File
Clock
Phasor
Memory Card Full
Write to SD
Recorder Name
1750
Memory Card Files
Cancel
Power Type Diagram
Harmonics
Normal Volts/Hz/Power Type
1750
Memory Card Files
SD Card Files
Trend
Return to Download
Delete File
Setup Password
Cancel
Erase 1750 Memory
Phase Swap
Trend
Snapshot Stored
Setup Volts/Current Scale
Setup Probe Detect
Erase All
Snapshot Interval
Setup IP Address
Check List
Data
Annotate
Memory
Insert Start Mark
Insert Stop Mark
Settings
Insert Text File
Insert File
azd15f.eps
Figure 16. Power View Menu Tree
30
Operators Manual
Home Screen
Home Screen
This is the top-level screen, accessed when you start Power View or when you tap View
and them Home on the Menu Bar.
The Home screen contains a 1.5 cycle waveform screen, a digital meter screen, and a
phasor screen. The parameters shown in this screen are not configurable. All phases are
shown simultaneously, either all voltage or all current.
Finding Recorders Within Range
If no Recorders are within range, the following screen appears:
11:35
Fluke Power View
ok
Connecting...
Unit:
1750 Power Recorder Not Found
OK
Cancel
Data View Setup
31
1750
Operators Manual
If more than one Recorder is within range, the Recorder selection screen appears. An
asterisk preceding the Recorder name means that unit is password protected.
11:35
Fluke Power View
ok
1750 Power Recorders Found
Unit:
*larson BLDG -SN12345
*larson BLDG -SN98765
larson BLDG -SN97532
Data View Setup
If the selected Recorder is not password protected, the Home screen appears. If password
protection is set, the Password screen appears instead.
11:35
Fluke Power View
ok
Password
Unit:
*larson BLDG -SN12345
Password:
highway17
OK
Cancel
Data View Setup
If you enter an incorrect password, the following message appears:
11:35
Fluke Power View
Password
Unit:
*larson BLDG -SN12345
Password:
highway17
Password not correct
OK
Data View Setup
32
Cancel
ok
Operators Manual
Downloading Data and Erasing Memory
When the password is accepted, the Home screen appears.
Note
A screen to set up password protection for a Recorder is provided in the
Setup menu.
Downloading Data and Erasing Memory
Use the Data menu options to manage the Recorder memory and download recorded data
to the SD card. You are downloading recorded data from the flash memory to an SD card
in the Recorder. When you want to use that data, you must move the card to the PDA.
You can later copy the data to your PC for review using the Power Analyze software. Tap
1750 Internal Memory to view the Download screen.
The Download screen shows a three-phase rms V strip chart with date and timescale
shown. This is the data in the Recorder internal memory. The default settings of the start
and stop times is everything in memory, to download ALL, tap the Write to SD button.
The gray cursor lines right and left with triangular arrowheads at the bottom of the screen
show the start and stop times currently selected for download. Green and red flags are
START and STOP mark annotations inserted during the recording session. Yellow flags
are file name annotations inserted during the recording session.
33
1750
Operators Manual
If the SD storage card already contains data files, it may not have room for the new
download. Power View alerts you to this condition and asks if you would like to erase the
SD card before downloading.
Fluke Power View
11:35
ok
*larson BLDG -SN12345
DOWNLOAD
AN
SD Card Full,
Remove Files to Save
BN
CN
From:
04/04/04 12:30 PM
22.5 MB
Write to SD
Data View Setup
34
To:
04/14/04 01:15 AM
Cancel
Operators Manual
Downloading Data and Erasing Memory
The Memory Card Full message appears for 5 seconds, followed by the screen below.
You can also access the download menu by selecting Data > Recorder SD Memory.
You can delete files as necessary, and when satisfied that there is room on the card,
proceed to write the selected internal Recorder memory data to the SD card.
11:35
Fluke Power View
ok
*larson BLDG -SN12345
SD CARD FILES
Stored files:
File Name
Date
Size
Data View Setup
When there is room on the card, a message confirming the download will appear.
You can also tap the Erase Recorder Memory from the Data menu option, and tap the
Erase All button to erase all power quality data stored in the Recorder. Recorder memory
is typically erased after power quality data has been saved on the SD card, although you
can leave old data in Recorder memory. It will be overwritten automatically when you
start your next Recorder session, so it never has an adverse effect on recorded data
quality or quantity.
35
1750
Operators Manual
11:35
Fluke Power View
*larson BLDG -SN12345
ERASE RECORDER MEMORY
AN
BN
CN
Erase All
Data View Setup
When you choose to Erase All, the following popup caution “Are you sure?” appears on
the screen.
Note
You can also download data by connecting your PC directly to the
Recorder with an Ethernet cable and run Power Analyze in the 1750 Live
mode. All of the functions (controller, PDA, and Power View) are
duplicated in 1750 Live mode.
36
Operators Manual
Viewing Live Data
Viewing Live Data
The View menu is used to view live data on the circuits on the circuits for example,
Scope, Meter, Phasor, or Harmonics.
Scope Screen
The Scope screen shows 1.5 cycle waveform data for the volts and amp lines selected in
the check boxes on Phase View screen. Tap the Phase icon ( ) to display the Phase
View screen.
37
1750
Operators Manual
Meter Screen
The Meter screen shows numeric readings for all selected phases.
Phasor Screen
The PHASOR screen shows voltage (long arrows with solid arrowheads), current
amplitudes, and phase angles. This screen is used to verify proper test lead and current
probe connections.
You can easily correct an erroneous Recorder connection by going directly to
Setup\Phase Swap ( ) and using the Recorder to internally invert a CT, swap a voltage
or CT phase, or modify a scaling parameter, then return to the screen to verify that the
correction has been made. There is no need to touch the cables. See “Phase Swap” later in
the manual for additional information.
38
Operators Manual
Viewing Live Data
Trend Screen
The Trend screen shows live data being recorded as a strip chart display of the selected
phases of voltage or current. This moment in time is visible on the right side of the graph.
The traces fill the screen in 10 minutes, and continue FIFO (first-in, first-out). This
feature is intended to paint a picture of the short-term stability of the power system.
Harmonics Screen
The Harmonics screen shows the magnitudes of the selected phases of V and I. The scale
is % of nominal.
The slider control displays harmonics of a higher order up to the 50th.
If the power type is delta, V phases are AB, BC, and CA (L1L2, L2L3, L3L1 is available
as a localized European labeling scheme). If the power type is Wye, V phases are AN,
BN, CN, and NG. (N = neutral, G = ground).
39
1750
Operators Manual
Viewing Phases
In all the detail Live View screen, a line selection menu is available using the
button
at the bottom. The Phase Selection screen reveals check boxes for selecting the voltage
and current channels you want to display.
Setting Up the Recorder
To adjust the settings of the Recorder, tap Setup > 1750 Setup.
The Setup screen shows set up options, with icons for available actions.
40
Operators Manual
Setting Up the Recorder
From the Setup screen, you can adjust either the recording period information or the
Recorder settings. Tap an icon on the Setup screen to view or configure:
•
Clock
•
Probe Detect
•
IP Address
•
Nominal Power
•
Instrument Name/Password
•
Phase Swap
•
Volts/Current Ratio
•
Snapshot Period
Setting the Clock
Use this feature to set the PDA clock or clock to synchronize the Recorder with the PDA
clock.
41
1750
Operators Manual
Probe Detect
This screen shows the types of probes attached to the Recorder current inputs. Current
probes are automatically detected.
42
Operators Manual
Setting Up the Recorder
Setting the IP Address
Select Automatically Obtain Address unless your company's IT department has specific
requirements that require assigned IP addresses.
Overwriting Nominal Power Values
Nominal power values are auto-detected by the Recorder and shown as the defaults. You
can overwrite these settings by change the Recorder’s internal configuration to optimize
power quality data recording custom settings.
43
1750
Operators Manual
Assign Recorder Name and Password
Use this feature to assign a name identifier to the Recorder and to establish a password
for the Recorder. This naming feature is designed to help you keep track of which
Recorder is in use.
Using Phase Swap
Rather than having to change the physical connections to the power system, use the Phase
Swap feature to make a software-selectable correction without physically switching the
cable. You can select from the following:
•
Swap any voltage input
•
Swap any current input
•
Invert any current input clamp
The screen shows check boxes to invert any current probe. Current probes are directional,
and selecting “invert” has the effect of removing the probe and turning it around.
If the power type is delta, V phases are AB, BC, and CA (L1L2, L2L3, L3L1 is available
as an optional setting). If the power type is Wye, V phases are AN, BN, CN, and NG. (N
= neutral, G = ground).
44
Operators Manual
Setting Up the Recorder
Setting the Volts and Current Ratio
Use this menu to add a ratio factor to the voltage or current input on each phase.
Changing the first “1” in each case if there is a potential transformer in series with the
voltage connection such as when you want to monitor a medium-voltage network using
PTs and CTs to scale the voltage and current to a convenient level for measuring
instruments.
The current ratio applies a ratio to the current input in order to show the current present
on a medium-voltage network. This feature is intended to be used for sensing low levels
of current to represent the much higher levels on the primary side at a substation or
step-down transformer that has built-in metering current transformers.
45
1750
Operators Manual
Setting the Snapshot Period - Periodic Waveform Capture Setting
Use the Snapshot Period screen to program the Recorder to take automatic power
conditions readings which are then stored in the recorded data stream.
•
None
•
10 minutes
•
30 minutes
•
1 hour
Note
You can take a snapshot manually at any time at any time while connected
over the wireless link to a Recorder. Press the Waveform icon
on any of
the View screens to take a snapshot. The message, “Snapshot Acquired”
confirms that a snapshot was taken.
46
Operators Manual
Setting Up the Recorder
Working with Annotations
Annotations are optional markers that can be inserted by the Recorder operator to flag a
particular point in the data when recording. They are usually inserted on using Power
View with the wireless PDA.
There are five types of annotations:
•
Start annotation (green)
The Start annotation can be used to signify where important data begins. For example, the
operator might want to establish a start annotation after having finished all probe
connections and instrument setup, to indicate that any preceding data was preliminary.
Note
You are not limited to using the Start and Stop annotations in pairs, or to
show a range of data. You can use each as many times as desired to mark a
particular point during recording.
•
Stop annotation (red)
•
The Stop annotation can be used to signify where important data ends.
File annotation (yellow)
•
File annotations contain the name of a picture or audio file relevant to the data. See
“Using Image or Voice Annotations” later in this manual.
Text annotation
•
Text annotations contain a text note.
Power Configuration Change annotation
Power Configuration Change annotations are inserted by the system when a change is
made to the Power Configuration in the Recorder. These markers only display in the
Download dialog box.
To show or hide annotation markers
•
In the Volts/Amps/Hz or Events view, check or uncheck the Annotations option on the
view controls.
To open an annotation
•
In the Volts/Amps/Hz view, Events view, or Download dialog box, click on the
annotation.
47
1750
Operators Manual
If the annotation is associated with an audio (.WAV) or image (.jpg) file, the application
associated with that file will start and open the file. If the file is not in the default
directory My Documents\PQ, a dialog box opens so that you can navigate to the file.
Note
If clicking on an annotation marker does not seem to do anything, the Zoom
box is probably selected in the graph toolbar, instead of the Select tool.
Click the Select tool and then select the annotation.
To see overlapping annotations
Sometimes annotations are so close to each other that they actually overlap on the
Volts/Amps/Hz reference graph. When this is the case, if you click on overlapping
annotations, a menu opens and you can select either Open, to open the annotation now on
top, or Select Next Overlapping Annotation, to bring the next one to the top.
•
To open the annotation now on top, choose Open.
•
To bring the next annotation to the top, choose Select Next Overlapping Annotation. To
then open that annotation, click on it again and choose Open.
Note
To see overlapping annotations more clearly on the Volts/Amps/Hz
reference graph, move the selection cursors so that they just surround the
area that contains the overlapping illustrations. The Detail graph adjusts
as the cursors move, zooming in to show the area between the selection
cursors. You can now see the annotations separately.
Using Image or Voice Annotations
While you are monitoring data with a Recorder, you may find it helpful to take a picture
that relates to the power quality data you are recording, or to record verbal comments as
you observe the conditions or review the data being measured. You can then associate the
image or recording with the data being recorded by adding annotations that reference
them.
The PDA includes a microphone for recording notes which are saved as .WAV files, and
an optional camera accessory is available on the PDA which will capture images as .jpg
files.
You can associate both images and audio files with the data being gathered in the
Recorder by inserting annotations and specifying the name of a .WAV or .jpg file. After
you download data from the Recorder, you can then move the image and audio files to
the PC along with the recorded data (.odn) file.
Note
You can also associate other types of files with the annotation. For
example, if you had a .MPJ file with a movie, or a .DOC file with
associated information. You can enter any file name using this annotation
method.
Inserting Image or Voice Annotations
1. Set up the Recorder and begin monitoring.
2. Using your PDA-cam or another camera, take a picture of what you want to
capture.
3. Click the Annotate icon to display the Annotate screen.
48
Operators Manual
Cleaning and Maintenance
4. Move the image or audio file to a location that will make it easier to Transfer it to
a PC later, when you download and move the recorded data file to your PC. Place
the file into the synchronization folder on your PDA, so that it will be
automatically transferred into the sync folder on the PC the next time you dock
the PDA.
Cleaning and Maintenance
•
The Recorder contains no user serviceable parts. Contact an Authorized Fluke
Service Center for repair.
•
Periodically wipe the case with a damp cloth and mild detergent. Do not use
abrasives or solvents.
Regulatory Information for Wireless Communication
Caution
Any changes or modifications to the wireless 2.4GHz radio not
expressly approved by Fluke Corporation could void the user's
authority to operate the equipment.
FCC ID: T68FLK1750
IC: 6627A-FLK1750
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the
device.
Class A digital device: A digital device that is marketed for use in a commercial,
industrial or business environment, exclusive of a device which is marketed for use by
the general public or is intended to be used in the home.
Class B digital device: A digital device that is marketed for use in a residential
environment notwithstanding use in commercial, business and industrial environments.
Examples of such devices include, but are not limited to, personal computers, calculators,
and similar electronic devices that are marketed for use by the general public.
The Fluke 1750 Power Recorder (wireless host) has been tested and found to comply
with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
In addition, the internal limited modular radio has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
49
1750
Operators Manual
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
The term “IC:” before the radio certification number only signifies that Industry of
Canada technical specifications were met.
Specifications for the System: Recorder and Power Analyze
Software
General Specifications
Power Quality Measurement Standards
Conformance....................................................IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on
measurement function, IEEE519, IEEE1159, IEEE1459
Clock/Calendar.................................................Leap years, 24-hour clock
Real-time Clock Accuracy ...............................Not more than ± 0.3 s/day
Internal Memory Capacity for Data .................At least 1 GB
Maximum Recording Period ............................At least 1 month
Measurement Time Control .............................Automatic
Maximum Number of Events ...........................Limited only by the size of the internal memory.
Power Requirements .......................................90 to 264 V rms ±10%, 47-63 Hz, 40 W
Operating Time During Interruptions
(internal UPS operation).....................................5 minutes per interruption, 60 minutes total operating time without
recharging
Dimensions ......................................................215 x 310 x 35 mm (8.5 x 12.2 x 3.5 inch)
Mass (Weight)...................................................6.3 kg (14 lbs)
Input Specifications
Measurement Types.........................................One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split
Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three
Phase High Leg, Three Phase Open Leg, 2 Element Delta, 2 ½
Element Wye
Input Channels .................................................Voltage: 5 channels, AC/DC
Current: 5 channels
Voltage Channels.............................................Input resistance: 2 MΩ
Input capacitance: < 20 pF
Current Channels.............................................1 MΩ. Self-identifying probes
Types available: current clamps, Flexi-CTs
Measuring Method ...........................................Simultaneous digital sampling of voltage and current. Digital PLL
synchronized sampling, internal frequency reference used during
voltage drops.
Synchronization and Sampling
PLL-Synchronization Source ..........................The PLL synchronizes to the A-N voltage for wye power types, and t
the A-B voltage for delta power types. All listed power types can be
characterized as either wye or delta.
PLL Lock Range...............................................42.5 to 69 Hz
Sampling Frequency........................................Voltage and current: 256 samples/cycle
Inter-harmonics per IEC61000-4-7: 2560 points / 10 cycles (50 Hz),
3072 points/12 cycles (60 Hz)
Transient Voltage: 5 MHz
A/D Resolution .................................................Voltage and current: 24 bits
Transient voltage: 14 bits
50
Operators Manual
Specifications for the System: Recorder and Power Analyze Software
Voltage and Current Measurements
Voltage Measurement Range ..........................AC voltage: 1000 V rms ± 10% Overrange
DC voltage: ±1000 V + 10% Overrange
Voltage Crest Factor ........................................3 or less
Voltage Input Impedance.................................2 MΩ
Current Measurement Range ..........................Depends on current probe used
Current Crest Factor ........................................4 or less
Current Input Characteristics..........................2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low
impedance for Flexi-CTs
Voltage and Current Measurement Accuracy
RMS Voltage
Measurement Type ............................................True rms calculated continuously: every cycle, every 1/2 cycle, and
every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC
61000-4-30.
Measurement Uncertainty ..................................AC: ± 0.2 % reading ± 0.1 % full scale above 50 V rms
DC: ± 0.5 % reading ± 0.2 % full scale above 50 V dc
RMS Current
Measurement Type ............................................True rms calculated continuously: every cycle, every 1/2 cycle, and
every 10 or 12 cycles at 50 or 60 Hz respectively, as required by
standards
Measurement Uncertainty ..................................± 0.2 % reading ±0.1 % full scale + current sensor accuracy
Transient Voltage (Impulse)
Measurement Type ............................................Waveshape sampling, not peak detect
Full Scale...........................................................8000 V pk
Sample Resolution .............................................200 nS
Measurement Uncertainty ..................................± 5 % reading ± 20 V (test parameters: 1000 V dc, 1000 V rms,
100 kHz)
Dip (Sag) and Swell Measurements
Voltage Swell (rms swell)
Measurement Type ............................................True rms (one cycle calculation by overlapping each half cycle)
(voltage between lines is measured for 3P3W lines and phase voltage
is measured for 3P4W lines)
Displayed Data...................................................Amplitude and duration of swell
Measurement accuracy......................................Same as rms voltage
Voltage Dip (RMS sag)
Measurement Type ............................................True rms (one cycle calculation by overlapping each half cycle)
(voltage between lines is measured for 3P3W lines and phase voltage
is measured for 3P4W lines)
Displayed Data...................................................Amplitude and duration of dip or interruption
Measurement Accuracy......................................Same as rms voltage
Voltage Dropout (Interruption)
Measurement Type ............................................Same as Voltage Dip
Power and PF Measurement
Calculated per IEEE1459 for best performance when distortions exist
Measurement Type ............................................True rms calculated continuously: every cycle, and every 10 or 12
cycles at 50 or 60 Hz respectively, as required by standards
Measurement Accuracy......................................± 0.2% reading ± 0.1% full scale + current sensor accuracy
Frequency
Measurement Range..........................................42.5 to 69 Hz
Measurement Source.........................................Same as PLL synchronization source
Measurement Accuracy......................................± 10 mHz (10 to 110% of range, with sine wave)
51
1750
Operators Manual
Reactive Power
Accuracy............................................................± 0.2% reading ± 0.1% full scale + current sensor accuracy
Power Factor
Measurement Range..........................................-1.000 (leading) to 0.000 to +1.000 (lagging)
Measurement Accuracy......................................± 1 digit from the calculation of each measured value (±3 digits for
total)
Displacement Power Factor
Measurement Method ........................................Calculated from the phase difference between voltage fundamental
and current fundamental
Measurement Range..........................................- 1.000 (leading) to 0.000 to + 1.000 (lagging)
Measurement Accuracy......................................± 0.5% reading ± 2% full scale ± 1 digit
Voltage Unbalance and Phase Sequence
Measurement Method ........................................Positive sequence voltage divided by negative sequence voltage, per
IEC 61000-4-30
Harmonic Voltage and Current
Analysis Window................................................rectangular
Analysis Order ...................................................1st to 50th order
Measurement Accuracy......................................Voltage / Current: 1st to 20th orders: ± 0.5% reading ± 0.2% full scale
21st to 50th orders: ± 1% reading ± 0.3% full scale
(current sensor accuracy must be included for current and power)
Measurement Method ........................................IEC 61000-4-7
Inter-harmonic Voltage and Current (Intermediate Harmonics)
Analysis Window................................................rectangular
Analysis Orders..................................................0.5 to 49.5th order
Measurement Method ........................................IEC 61000-4-7
External Interface Specifications
LAN Interface
Connector ..........................................................RJ-45
Speed and Type.................................................10/100Base-T, auto MDIX
Communications Protocol ..................................TCP/IP over Ethernet
Wireless Controller Interface
Connection.........................................................wireless (2.4 GHz radio)
Speed ................................................................up to 700 kbit/second
Communications Protocol ..................................Bluetooth SPP
Environmental and Safety Specifications
Operating Environment ......................................indoors or in covered area outdoors, up to 2000 m altitude
Storage Temperature and Humidity....................-20 °C to 50 °C, 80 % rh max, non-condensing
Operating Temperature and Humidity ................0 °C to 40 °C, 80 % rh max, non-condensing
Maximum Rated Working Voltage
Voltage Terminals ............................................1100 V rms
Voltage Durability...............................................5550 V rms ac for 1 minute, between voltage input terminals, voltage
input terminals and current probes, and voltage input terminals and
case (50/60 Hz, 1 mA sense current)
Enclosure Protection ..........................................IP30 (per EN 60529)
Standards Conformance
EMC...................................................................EN 61326-1:1997+A1:1998 Class A
EN 61000-3-2:1995+A1:1998+A2:1998
EN 61000-3-3:1995
Safety ................................................................EN 61010-1:1993+A2:1995
Voltage input unit: Contamination Level 2
Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated
overvoltage: 8000 V)
52

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Signing Date                    : 2006:08:04 13:34:16-07:00
Signing Authority               : ARE_Acrobat Collaboration V7.0 P9 0000109
Annotation Usage Rights         : Create, Delete, Modify, Copy, Import, Export
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2006:08:04 13:34:16-07:00
Create Date                     : 2006:08:04 13:31:43-07:00
Metadata Date                   : 2006:08:04 13:34:16-07:00
Format                          : application/pdf
Title                           : Microsoft Word - 0master.doc
Document ID                     : uuid:5f885dc9-18b9-478a-b091-08a2a95a544b
Instance ID                     : uuid:dde502d4-0f16-4c2e-8669-3214243fe2f6
Has XFA                         : No
Page Count                      : 60
Creator                         : PScript5.dll Version 5.2.2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: T68FLK1750

Navigation menu