Fluke 114 Data Sheet

The-Fluke-114-Digital-Multimeter-Data-Sheet-Brochure The-Fluke-114-Digital-Multimeter-Data-Sheet-Brochure

2015-09-09

: Fluke Fluke-114-Data-Sheet-805284 fluke-114-data-sheet-805284 fluke pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

Technical Data
Fluke 114
Electrical Multimeter
Features include:
AutoVolt: automatic ac/dc voltage selection
Large white LED backlight to work in poorly lit areas
Resistance and continuity
Min/Max/Average to record signal fluctuations
CAT III 600 V safety rated
Compact true-rms
meter for electrical
troubleshooting
The Fluke 114 is the troubleshooting
tool for “go/no-go” testing. It includes
a feature to prevent false readings
caused by ghost voltage.
General specifications
Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 90 %.
The accuracy specifications take the form of:
± ( [ % of Reading ] + [ Counts ] )
Maximum voltage between
any terminal and earth
ground
600 V
Surge protection 6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Operating temperature -10 °C to + 50 °C
Storage temperature -40 °C to + 60 °C
Battery 9 volt Alkaline, NEDA 1604A/
IEC 6LR61
Battery life 400 hours typical, without backlight
N10140
R
Actual size
Accuracy specifications
2 Fluke Corporation 114 Electrical Multimeter
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 10/2006 2634055 D-EN-N Rev B
Fluke. Keeping your world
up and running.
Ordering Information
Fluke-114 Electrical Multimeter
Included
TL75 Test leads, holster, User’s manual
and 9 V battery (installed).
Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2
DC volts 6.000 V 0.001 V
0.5 % + 260.00 V 0.01 V
600.0 V 0.1 V
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms 6.000 V 0.001 V
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
60.00 V 0.01 V
600.0 V 0.1 V
Continuity 600 W1 WBeeper on < 20 W, off > 250 W; detects
opens or shorts of 500 µs or longer.
Ohms 600.0 W0.1 W0.9 % + 2
6.000 kW0.001 kW
0.9 % + 1
60.00 kW0.01 kW
600.0 kW0.1 kW
6.000 MW0.001 MW
40.00 MW0.01 MW1.5 % + 2
Notes:
1 All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified,
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected
from a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full
scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.