Fluke 115 Data Sheet
2015-09-09
: Fluke Fluke-115-Data-Sheet-805268 fluke-115-data-sheet-805268 fluke pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Fluke 114, 115, 116 and 117 Digital Multimeters Extended specifications Technical Data General specifications (all models) Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity of 0 % to 90 %. Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 W Fuse for A input 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec Temperature Operating: -10 °C to +50 °C; Storage: -40 °C to +60 °C Humidity 0 % to 90 % to 35 °C; 75 % to 40 °C; 45 % to 50 °C Temperature coefficient 0.1 x (specified accuracy/°C) (< 18 °C or > 28 °C) Operating altitude 2,000 meters Battery 9 Volt Alkaline, NEDA 1604A/IEC 6LR61 Battery life Alkaline: 400 hours typical, without backlight Safety compliances ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 Certifications UL, CSA, TUV, N10140 , VDE IP rating (dust and water protection) IP42 N10140 Accuracy specifications (all models) Accuracy ± ([% of Reading] + [Counts]) Model 0.1 mV 0.5 % + 2 114, 115, 116, 117 0.001 V 0.01 V 0.1 V 0.5 % + 2 114, 115, 116, 117 Function Range Resolution DC millivolts 600.0 mV DC volts 6.000 V 60.00 V 600.0 V DC, 45 Hz to 500 Hz Auto-V LoZ true-rms 1 600.0 V 0.1 V 500 Hz to 1 kHz 2.0 % + 3 4.0 % + 3 45 Hz to 500 Hz 500 Hz to 1 kHz 114, 116, 117 AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3 114, 115, 116, 117 AC volts1 true-rms 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V 1.0 % + 3 2.0 % + 3 114, 115, 116, 117 Continuity 600 Ω 1Ω Ohms 600.0 Ω 6.000 kΩ 60.00 kΩ 600.0 kΩ 6.000 MΩ 40.00 MΩ Diode test Capacitance LoZ capacitance (power-up option) 1 nF to 500 µF Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 µs or longer 114, 115, 116, 117 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ 0.9 % + 2 0.9 % + 1 0.9 % + 1 0.9 % + 1 0.9 % + 1 1.5 % + 2 114, 115, 116, 117 2.000 V 0.001 V 0.9 % + 2 115, 116, 117 1000 nF 10.00 µF 100.0 µF 9999 µF 1 nF 0.01 µF 0.1 µF 1 µF 1.9 % + 2 1.9 % + 2 1.9 % + 2 100 µF to 1000 µF: 1.9 % + 2 > 1000 µF: 5 % + 20 115, 116, 117 10 % + 2 typical 115, 116, 117 All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of ≤ 3. AC volts is ac-coupled. Auto-V LoZ, ac mV, and ac amps are dc-coupled. 1 Accuracy specifications (all models) cont. Accuracy ± ([% of Reading] + [Counts]) Model 0.1 °C 0.2 °F 1 % + 102 1 % + 182 116 6.000 A 10.00 A 20 A overload for 30 seconds maximum 0.001 A 0.01 A 1.5 % + 3 115, 117 AC µAmps true-rms1 (45 Hz to 1 kHz) 600.0 µA 0.1 µA 1.5 % + 3 (2.5 % + 3 > 500 Hz) 116 DC amps 6.000 A 10.00 A 20 A overload for 30 seconds maximum 0.001 A 0.01 A 1.0 % + 3 115, 117 DC µAmps true-rms 600.0 µA 0.1 µA 1.0 % + 2 116 Hz (V or A input)2 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 % + 2 115, 117 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 % + 2 116 Function Range Resolution Temperature (K-Type thermocouple) -40 °C to 400 °C -40 °F to 752 °F AC amps true-rms1 (45 Hz to 500 Hz) Hz (V input)3 All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of ≤ 3. AC volts is ac-coupled. Auto-V LoZ, ac mV, and ac amps are dc-coupled. 2 AC Volts Hz is ac-coupled and specified from 5 Hz to 50 kHz. AC Amps Hz is dc-coupled and specified from 45 Hz to 5 kHz. Amps input burden voltage (typical): 6 A input 2 mV/A, 10 A input 37 mV/A. 3 Frequency is ac-coupled, 45 Hz to 50 kHz. 1 Frequency counter sensitivity (models 115, 116, 117) Typical sensitivity (rms sine wave) Input range Volts AC AC Amps (115, 117 only) 5 Hz to 45 Hz 45 Hz to 5 kHz 5 kHz to 10 kHz 10 kHz to 50 kHz 6V 60 V 600 V 0.2 V 2V 20 V 0.2 V to 0.3 V 2 V to 3 V 20 V to 30 V 0.3 V to 0.4 V 3 V to 4 V 30 V to 40 V 0.4 V to 1.0 V 4 V to 10 V 40 V to 100 V 6A 10 A N/A N/A 0.4 A 0.5 A N/A N/A N/A N/A Input characteristics (all models) Function Input impedance (nominal) Common mode rejection ratio(1 kΩ unbalanced) Volts AC > 5 MΩ < 100 pF > 60 dB at dc, 50 or 60 Hz Volts DC > 10 MΩ < 100 pF > 100 dB at dc, 50 or 60 Hz ~3 kΩ < 500 pF > 60 dB at dc, 50 or 60 Hz Auto-V LoZ Open circuit test voltage Ohms < 2.7 V dc Diode Test < 2.7 V dc Full scale voltage Normal mode rejection > 60 dB at 50 or 60 Hz Short circuit current To 6.0 MΩ 40 MΩ < 0.7 V dc < 0.9 V dc 2.000 V dc Fluke. Keeping your world up and running.™ Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands < 350 μA < 1.2 mA For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 11/2006 2793260 D-EN-N Rev A Fluke Corporation Fluke 11X Series Digital Multimeters Extended Specifications
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1.1-111 About : d2fb1c22-880f-11da-9b03-9ca4bb25846e Create Date : 2006:12:01 09:22:23-08:00 Metadata Date : 2006:12:01 09:22:25-08:00 Modify Date : 2006:12:01 09:22:25-08:00 Creator Tool : Adobe InDesign CS2 (4.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 10965 bytes, use -b option to extract) Instance ID : uuid:82f2012a-8160-11db-bef4-000a95b26bba Document ID : adobe:docid:indd:1b431827-6585-11db-9e2f-f0739d794614 Rendition Class : proof:pdf Derived From Instance ID : f7f27a5e-6538-11db-b823-9e3c16ba1a48 Derived From Document ID : adobe:docid:indd:f7f27a5d-6538-11db-b823-9e3c16ba1a48 Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CS2 (4.0.4)EXIF Metadata provided by EXIF.tools