Fluke 1507 Users Manual
2015-09-09
: Fluke Fluke-1507-Users-Manual-808104 fluke-1507-users-manual-808104 fluke pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Manual Supplement Manual Title: Part Number: Print Date: Revision/Date: 150X Series Calibration Supplement Issue: 2465477 Issue Date: November 2005 Page Count: 1, 7/07 7 11/14 1 This supplement contains information necessary to ensure the accuracy of the above manual. Enter the corrections in the manual if either one of the following conditions exist: 1. 2. The revision letter stamped on the indicated PCA is equal to or higher than that given with each change. No revision letter is indicated at the beginning of the change. © 2008-2014 Fluke Corporation. All rights reserved. 150X Series Calibration Manual Supplement Change #1 On page 18, Table 5, Step 8, under Display Reading Limits for 1507/1508: Change: 0.6 to 0.15 To: 0.05 to 0.15 Change #2 On page 25, Table 10, Adjustment Step C-03, under Input Value Column: Change: 0.18 mA 0 Hz 20 μA, 0 Hz To: Change #3 On page 2, add the following to the Symbols table: Conforms to relevant South Korean EMC Standards. Conforms to CAN/CSA-C22.2 No. 61010-1, second edition, including Amendment 1. Change #4, 61173 On page 3, under General Specifications, replace Altitude with: Altitude ............................................. Operating: 2000 m CAT IV 600 V,Non Operating (Storage): 12,000 m Change #5, 64919, 65176, 367 On page 3, under General Specifications, remove Shock, Electromagnetic Compatibility, Safety, Certifications, and add: Safety ..................................................................... IEC 61010-1: 600 V CAT IV, Pollution Degree 2 Electromagnetic Environment ............................. IEC 61326-1: Portable Electromagnetic Compatibility ............................ Applies to use in Korea only. Class A Equipment (Industrial Broadcasting & [1] Communication Equipment) [1] This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. Change #6, 79 On page 20, under Testing the OHM Function, replace steps 1 and 4: 11/14 1. Connect the UUT COM and Ω terminals to the Fluke 5320A low resistance output terminals in a 2-wire configuration. 4. Apply the calibrator output listed in Table 9, steps 1-3. Prior to step 1, set the 5320A Ohms output to Short and press the ZERO button on the UUT. Change the 5320A Ohms to 2-Wire mode. 1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2014:10:30 10:21:54-07:00 Modify Date : 2014:10:30 10:21:54-07:00 Producer : Acrobat Distiller 10.0.0 (Windows) Format : application/pdf Creator : Title : Document ID : uuid:36acb8ce-d6b5-40b4-9ac5-48eee9f79968 Instance ID : uuid:7427a112-e2b9-4e47-b50c-13d9d3ae3890 Page Count : 2 Author :EXIF Metadata provided by EXIF.tools