Fluke 28 Ii Brochure
2015-09-09
: Fluke Fluke-28-Ii-Brochure-805243 fluke-28-ii-brochure-805243 fluke pdf
Open the PDF directly: View PDF .
Page Count: 4
ATEX Example
Fluke 707Ex is ATEX Compliant II 2 G Ex ia IIC T4
The ATEX examination mark is required on all devices for use in
European hazardous areas.
ATEX Markings
II 2 G The classification of zones. “II” designates the tool is approved for
all non-mining areas. “2” represents the category of the device, in
this case the device is rated for the second most hazardous areas.
“G” designates atmosphere, in this case gas, vapors and mist.
Ex Explosion protection based on European Ex-regulations.
ia The type of protection from explosion, in this case the energy in a
device or connector has been reduced to a safe value.
IIC Gas Group. “IIC” rating indicates compatibility with the most
dangerous gas groups.
T4 Temperature class is the maximum
temperature of a surface that
may be.
FM Example
Fluke 707Ex is FM-classified N.I. Class I, Div 2,
Groups A-D, T4
The Factory Mutual Approved mark.
Factory Mutual Markings
N.I. Non-incendive apparatus, internal energy is limited so a specified
atmosphere cannot be ignited by its use.
Class I For use with gases, vapors and liquids (not dust, fibers or filings).
Div 2 Certified for use in Zone 2, explosive atmospheres not normally
present, may rarely exist for short duration.
Groups
A-D
Rated for use with explosive gasses as defined by groups A-D,
including acetylene, hydrogen, acetylene and propane.
Making sense of the
product rating systems
Each approved intrinsically safe device is rated to ATEX,
NEC, FM or other country standards. The corresponding
rating system allows you to understand which zones, type
of protection, gas groups and temperature classes the
instrument is approved for.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2005-2014 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 4/2014 2432675C_EN
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke. Keeping your world
up and running.
®
Fluke’s intrinsically safe tools can be used to help you perform
maintenance and calibration tasks in potentially explosive and
hazardous areas. Learn about the importance of intrinsic safety
on the job and the industries that use intrinsically safe tools.
Fluke offers a wide range of reliable, accurate and intrinsically
safe tools. Including the NEW 28II Ex True-rms Multimeter
and the NEW Fluke 568 Ex Infrared Thermometer, which
compliments the line of Fluke intrinsically safe field calibrators.
Fluke 718Ex
Pressure
Calibrator
Fluke 707Ex
Loop Calibrator
Fluke 28II Ex
True-rms Industrial
Multimeter
Fluke 568 Ex
Infrared
Thermometer
700G Series
Precision Pressure
Test Gauges
Fluke 725Ex
Multifunction
Process Calibrator
Fluke 700PEx
Pressure Modules
1551/1552 “Stik”
Thermometers
Fluke tools are designed
to keep you safe in
dangerous environments
Fluke 700PEx
Pressure Modules
Best suited for:
• Use with the Fluke 725Ex Multifunctional Process Calibrator and
Fluke 718Ex Pressure Calibrator to cover the most commonly used
pressure calibration ranges from 0-25 mbar up to 0-200 bar
Features:
• I.S. Class I Div 1 Groups A-D T4, Ta = 0 °C to +50 °C
• ATEX II 1G Ex ia IIC T4 compliant
• Very high accuracy up to 0.025 %
Legend
Motor Control Center Process Measurements
Flow Computer Process Controller
Tank Farm Pumping Station
For more information on these ATEX-compliant tools designed for tough process maintenance and calibration tasks, visit www.fluke.com/ex
Fluke Intrinsically Safe products
help to keep you safe on the job
“Intrinsically Safe” or I.S. is a
protection method employed
in potentially explosive atmo-
spheres. Certified I.S. tools are
designed to prevent the release
of sufficient energy to cause
ignition of flammable materi-
al. I.S. standards apply to all
equipment that can create one
or more of a range of defined
potential explosion sources:
• Electrical sparks
• Electrical arcs
• Flames
• Hot surfaces
• Static electricity
• Electromagnetic radiation
• Chemical reactions
• Mechanical impact
• Mechanical friction
• Compression ignition
• Acoustic energy
• Ionizing radiation
Industries that use or should
use I.S. tools include:
• Petro-chemical
• Oil platforms and refineries
• Pharmaceutical
• Pipelines
• Any environment where
explosive gases or vapors
could be present
1551/1552 “Stik”
Thermometers
Best suited for:
• Daily checks of working thermometers
• Custody transfer temperature determination, PET
calibration, LIG calibration, temperature transmitter
calibration and verification
Features:
• ATEX II 2 G Ex ib IIB T4 Gb, Ta -10 °C to 50 °C
1551A range: -50 °C to 160 °C (-58 °F to 320 °F)
1552A range: -80 °C to 300 °C (-112 °F to 572 °F)
• Accuracy (1 year): ± 0.05 °C (± 0.09 °F)
• Easy data logging available with 1552A
Fluke 725Ex Multifunction
Process Calibrator
Best suited for:
• Calibrating virtually any process parameter
Features:
• Class I Div 1 Groups B-D 171 °C
• ATEX II IG Ex ia IIB 171 °C Compliant
• Measure, source or simulate volts dc, mA, RTDs,
thermocouples, frequency and ohms
• 2-channel simultaneous source and measure capability
for calibration of transmitters
• Internal loop supply to power transmitters
• Store frequently-used test setups for later use
• Pressure measurement to 200 bar and pressure switch
test using any of the 8 Fluke 700PEx pressure modules
Fluke 568 Ex Intrinsically Safe
Infrared Thermometer
Best suited for:
• Taking spot, differential or scanning temperature
measurements in any environment where flam-
mable gases or vapors may be present
Features:
• Class I Div 1 and Div 2 or Zone 1 and 2
hazardous environments
• ATEX/IECEx, NEC-500/NEC-505, PCEC,
INMETRO certified
• Enhanced 50:1 distance to spot ratio allows user to measure
smaller objects from farther away
• Comfortable pistol grip makes target pointing an easy job
• Backlit display for poorly lit areas
• Displays Min/Max/DIF/AVG measurements and saves in memory
• Adjustable emissivity setting for more accurate measurements
• Log up to 99 measurements
• Compatible with mini-connector K-type thermocouple (KTC) probe
Fluke 707Ex Loop Calibrator
Best suited for:
• Calibration and maintenance of 4 to 20 mA control loop
Features:
• F.M. Class I Div 2 Groups A-D T4
• ATEX II 2G Ex ia IIC T4 compliant
• Large display and simple, quick-click push/rotary
button for easy one-handed operation
• Simultaneous mA and % readout for quick,
easy interpretation of readings
• mA accuracy of 0.015 %, superior to other loop calibrators
• Pushbutton with 25 % steps for fast, easy linearity checks
• 0 and 100 % ‘span check’ for fast confirmation of zero and span
For more information on these ATEX-compliant tools designed for tough process maintenance and calibration tasks, visit www.fluke.com/ex
Fluke 28II Ex True-rms
Industrial Multimeter
Best suited for:
• Solving problems on motor drives, in plant automation,
power distribution and electromechanical equipment
Features:
• Class I Div 1 Groups A-D
• ATEX II 2 G Ex ia IIC T4 Gb
• ATEX II 2 D Ex ia IIIC T130C Db
• ATEX I M1 Ex ia I Ma
• Low voltage troubleshooting in hazardous areas
• Built-in thermometer allows you to take temperature
readings
• Large digit display with bright, two-level
• IP67 rated, waterproof and dustproof
Best suited for:
• Pressure measurements and calibration with internal sensor
at pressure ranges of 2, 7 and 20 bar
Features:
• Class I Div 1 Groups A-D T4 Compliant
• ATEX II IG Ex ia IIC T4 compliant
• Built-in pressure/vacuum hand pump, with vernier and
bleed valve
• Pressure measurement to 200 bar using any of the 8 Fluke
700PEx Pressure Modules
• Pressure measurement to 0.05 % of full span using internal
pressure sensor
• Pressure switch test function
700G Series Precision
Pressure Test Gauges
Best suited for:
• Precision pressure measurement from
0 inH2O/20 mbar to 10,000 psi/690 bar and
absolute pressure measurement
Features:
• CSA; Class 1, Div 2, Groups A-D rating
• ATEX rating: II 3 G Ex nA IIB T6
• Accuracy to 0.05 % of full scale
• Reference class gauge accuracies to 0.04 % of reading
• Log up to 8,493 pressure measurements to memory
Fluke 718Ex Pressure Calibrator