Manual Supplement
Manual Title:
28 II Ex Getting Started
Print Date:
November 2011
Part Number
3945752
Revision/Date:

Supplement Issue:
Issue Date:
Page Count:

4
6/13
8

This supplement contains information necessary to ensure the accuracy of the
above manual.

© 2012-2013 Fluke Corporation. All rights reserved.



28 II EX Getting Started

Manual Supplement

Change #1, 60849 & 60854
On page 1, replace the third paragraph with:
The Product is designed for operation in potentially explosive areas of Zone 1, 2, 21, 22, and M1 as specified in
Directive 1999/92/EC and 94/9/EC (ATEX). There can be dangerous consequences If you do not follow these
instructions.

On page 7, replace the entire page with:

2/12

1

28 II EX Getting Started

Manual Supplement

Ex-Certification Data


Ex-Type certificate no: PTB 11 ATEX 2028 X
IECEx PTB 11.0080X



Ex-Designation: ATEX: II 2G Ex ia IIC T4 Gb
II 2D Ex ia IIIC T130 C Db
I M1 Ex ia I Ma

P0 = negligible Ri = 2.47K

Lo/Co

IECEx: Ex ia IIC T4 Gb
Ex ia IIIC T130 C Db
Ex ia I Ma


CE: CE0102



Operating Temperature: -15 C to 50 C



Storage Temperature: -40 C to +60 C



Batteries: 3 AAA Alkaline batteries, NEDA 24A IEC
LR03. Table 7 shows the approved batteries for this
Product.

9.54 V
negligible
3.7 mA
Ii
negligible

100

2

0.5

0.1

0.01

Co/F

0

0.61

1

1.4

2.1

3.6

U0
C0
I0
L0
P0

=
=
=
=
=

0V
Ui = 65 V
1000 F Ci = negligible
0mA
1000 mH Li = negligible
0 mW

mA/A Jack
U0
Ci
I0
Li
P0

Voltage – measurement input Ui = 65 V:
=
=
=
=

1000

Current – measurement input Ii = 5 A:

For connections to intrinsically-safe circuits, observe
these Product connections:
U0
Ci
I0
Li

Lo/mH

=
=
=
=
=

1.95 V
Ui = 65 V
negligible
9.7 A
Ii = Internally limited by a 440 mA fuse
negligible
negligible

= negligible

2

2/12

28 II EX Getting Started

Manual Supplement

Lo/Co
Lo/mH

1000

100

5

1

0.5

0.005

Co/F

0

14

19

25

30

1000

For measurements on protected electric circuits:


Approved for Zones 2 and 1, device group II,
explosion group IIC (explosive gases, vapors and
mist), temperature class T4.



Approved for Zones 21 and 22, device group II,
explosion group IIIC, conducting and nonconducting dust, fibers, and flyings.



Approved for use in mines. Device group I,
explosion group I, methane, and coal dust.

2/12

3

28 II EX Getting Started

Manual Supplement

On page 22, replace Table 8 with:
Table 8. Replacement Parts
Qty.

Fluke Part or
Model Number

Fuse, 11 A, 1000 V, FAST

1

803293

28 II Ex Fuse Assembly

1

4016494

Alligator Clip, Black

1

Alligator Clip, Red

1

Test Lead Set

1

TL175

28 II Ex Manual Information Pack (Includes Users Manual, CD & Getting Started Manual)

1

4013990

Fluke Input Cap, Amp Jack Plugs for DMM (10 packs)

1

4145825

Description

AC172 or AC175

 To ensure safety, use exact replacement only.

On page 23, replace Figure 4 with:

4

2/12

28 II EX Getting Started

Manual Supplement

Alligator Clips
Fuse Assembly
*Contains 440 mA
Fuse

Test Lead Set

Fuse
11 A,
1000 V, Fast

Amp Jack
Plug set

28 II Ex Manual
Information Pack

grt11.eps

Figure 4. Replacement Parts

2/12

5

28 II EX Getting Started

Manual Supplement

On page 24, Replace Table 9 with:
Table 9. Accessories
Item

Description

AC172 or
AC175

Alligator Clips

TL175

Silicone test lead set with probes

Amp Jack
Plug Set

2 Pack for DMM’s

I400

 AC Current Clamp [1]

80PK-27

 Temperature Probe [2]

All accessories in this table are approved for use in explosive hazardous environments. Fluke accessories are available
from an authorized Fluke distributor.
[1]  Warning - To prevent personal injury or property damage, do not use this accessory in hazardous areas where
dust is moved, transported, or conveyed.
[2]  Warning - To prevent personal injury or property damage, do not use this accessory in dust hazardous areas.

6

2/12

28 II EX Getting Started

Manual Supplement

On page 25, under Temperature replace Storage with:
Storage

-40 C to +85 C (without battery)
-40 C to +60 C (with battery)

Change #2, 62942
On page 32, replace Duty Cycle (Vdc and mVdc) with:
Duty Cycle (Vdc and mVdc)
Range
0.0 % to 99.9 %

[1]
[2]

Accuracy
[1]

Within  (0.2 % per kHz + 0.1 %) for rise times <1 s.

0.5 Hz to 200 kHz, pulse width >2 s. Pulse width range is determined by the frequency by the
frequency of the signal.
For 6 V dc range accuracy is unspecified.

On page 33, under MIN MAX Recording change:
From:
250 s (peak)

[1]

Specified accuracy 100 counts for changes >250 s in duration
(add 100 counts for readings over 6000 counts)
(add 100 counts for readings in Low Pass mode)

To:
250 s (peak)

4/12

[2]

[1]

Specified accuracy 200 counts for changes >250 s in duration
(add 100 counts for readings over 6000 counts)
(add 100 counts for readings in Low Pass mode)

7

Manual Supplement

28 II EX Getting Started

Change #3, 65782

On page 2, under Safety Information remove The Product complies with: and all the bullets.

On page 8, in the Symbols table, remove CAT III, CAT IV and CSA C1 and add:



Conforms to relevant South Korean EMC Standards

CAT II

Measurement Category II is applicable to test and measuring circuits connected directly
to utilization points (socket outlets and similar points) of the low-voltage MAINS
installation.

CAT III

Measurement Category III is applicable to test and measuring circuits connected to the
distribution part of the building’s low-voltage MAINS installation.

CAT IV

Measurement Category IV is applicable to test and measuring circuits connected at the
source of the building’s low-voltage MAINS installation.

On page 26, replace Electromagnetic Compatibility and IP Rating with the following, and
remove Shock, Safety Compliance and Certifications and add:
IP Rating .......................................................... IEC 60529: IP67 (Non-operating)
Safety ............................................................... IEC 61010-1: 600 V CAT IV / 1000 V CAT III, Pollution Degree 2
Electromagnetic Environment....................... IEC 61326-1: Portable
Electromagnetic Compatibility ...................... In an RF field of 3 V/M, accuracy = specified accuracy +20 counts, except 600 A
dc range total accuracy = specified accuracy +60 counts. Temperature not
specified
Applies to use in Korea only. Class A Equipment (Industrial Broadcasting &
[1]
Communication Equipment)
[1]
This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and is not to be
used in homes.

8

6/13



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : otto
Create Date                     : 2013:06:19 13:43:56-07:00
Modify Date                     : 2013:06:19 13:53:32-07:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2013:06:19 13:53:32-07:00
Format                          : application/pdf
Title                           : Microsoft Word - MS4.doc
Creator                         : otto
Producer                        : Acrobat Distiller 10.1.7 (Windows)
Document ID                     : uuid:97d4b80e-1808-48c3-b68c-112ef835a848
Instance ID                     : uuid:10bf8aa5-d4d8-4916-8ea7-503633e7cca2
Page Count                      : 9
EXIF Metadata provided by EXIF.tools

Navigation menu