Fluke 714 Thermocouple Users Manual
Fluke-717-Series-Pressure-Calibrators-User-Mnaual-Supplement-Brochure Fluke-717-Series-Pressure-Calibrators-User-Mnaual-Supplement-Brochure
2015-09-09
: Fluke Fluke-714-Thermocouple-Users-Manual-806137 fluke-714-thermocouple-users-manual-806137 fluke pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Manual Supplement Manual Title: Print Date: Revision/Date: 718 Users July 1998 4, 3/06 Supplement Issue: 6 Issue Date: 1/15 Page Count: 3 This supplement contains information necessary to ensure the accuracy of the above manual. This manual is distributed as an electronic manual on the following CD-ROM: CD Title: CD Rev. & Date: CD PN: © 2007-2015 Fluke Corporation. All rights reserved.. 718 3, 2/2006 1549626 718 Users Manual Supplement Change #1, 41517 On page 26, following the Weight specification add: Protection Class: Pollution Degree II Change #2 On page 5, under Table 3, add the following: Conforms to relative Australian standards Change #3 On page 1, replace the fifth paragraph with the following: Your Calibrator is supplied with a holster, two installed 9 V alkaline batteries, one set of TL75 test leads, one set of AC70A alligator clips, a Product Overview Manual, and a CD-Rom. Change #4, 59695 On page 1, under the Pressure Calibrator heading replace the first paragraph with: The Calibrator makes 5-digit pressure readings in the following units: psi, inH2O at 4 °C, inH2O at 20 °C, kPa, 2 cmH2O at 4 °C, cmH2O at 20 °C, bar, mbar, kg/cm , inHg, mmHg, and inH2O at 60 °F. 9/11 1 Manual Supplement 718 30G/100G Users Manual On page 2, add the following to Table 1: inH2O at 60 °F On page 25, replace the Pressure Sensor Input Table with: Pressure Sensor Input Model Range Max Accuracy [1] 6 month -1 to 1 psi 5 psi -7 to 7 kPa 34.5 kPa 718 30G -12 to 30 psi 60 psi -83 to 207 kPa 413 kPa 718 100G -12 to 100 psi 200 psi -83 to 690 kPa 1.4 mPa 718 300G -12 to 300 psi 375 psi -83 to 2.1 mPa 2.6 mPa 718 1G [1] 1 year 0.050 % 0.050 % 0.025 % 0.035 % 0.025 % 0.035 % 0.035 % 0.050 % In an RF field of 1 V/m to 3 V/m between the frequencies of 1.4 GHz to 2.0 GHz, add 120 counts to specified accuracy. 2 9/11 718 Users Manual Supplement Change #5, 59845 In the Specification section, add the following: Specifications apply to the 718 Pressure Calibrators with firmware version 4.0 or greater. To verify the firmware version, press and hold and power on the Calibrator. Change #6, 67387 On page 5, under Table 3, add: Conforms to relevant South Korean EMC Standards. On page 26, under General Specifications, add: Electromagnetic Compatibility .......... Applies to use in Korea only. Class A Equipment (Industrial Broadcasting & Communication Equipment) This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. Change #7, 37 On page 1, replace the fifth paragraph with: The Calibrator is supplied with a holster, two installed 9 V alkaline batteries, one set of TL75 test leads, one set of AC70A alligator clips, a Product Overview Manual, and a CD-Rom. 1/15 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2015:01:22 08:53:22-08:00 Modify Date : 2015:01:22 08:53:57-08:00 Metadata Date : 2015:01:22 08:53:57-08:00 Producer : Acrobat Distiller 10.0.0 (Windows) Format : application/pdf Title : untitled Document ID : uuid:3d2cbb6f-e4d3-4611-a399-13bd4db7f1f2 Instance ID : uuid:cda09303-4c5e-4803-b72d-cb05c52c74a1 Page Count : 4EXIF Metadata provided by EXIF.tools