Report # EMC2008Nov17-1420 ELECTROMAGNETIC COMPATIBILITY TEST CERTIFICATE for the Fluke 789 Processmeter The Fluke 789 was tested to the following standard at the EMC laboratories of Fluke Corporation. EN 61326-1 :2006 Class A Emissions and Immunity The Fluke 789 passes test requirements for equipment used for: □ Industrial Locations □ Controlled EM Environments ▣ Non-Domestic Use (Class A) ▣ Portable Equipment □ Domestic Use (Class B) Class A equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Prepared by: Michael Meisner ______________________________________ EMC Technician Specialist 17 Nov 2008 Date: _______________________ Reviewed by: Thomas Smith _______________________________________ Test Engineer Sr. 17 Nov 2008 Date: _______________________ Approved by: Product Evaluation Manager Division Engineering Manager TABLE I. Test Results The Fluke 789 Processmeter was tested to the following Electromagnetic Compatibility [EMC] requirements: Port Enclosure AC mains Frequency MHz 30 to 230 230 to 1000 0.15 to 0.5 0.5 to 5.0 5 to 30 Adapted from CISPR 11 Table 2a Emissions Limits for Class A Equipment Limits Standard Pass/Fail CISPR 11 Pass1 Pass1 N/A N/A N/A 40dB (uV/m) quasi peak, measured at 10 meters. 47dB (uV/m) quasi peak, measured at 10 meters. 79dB (uV/m) quasi peak, 66dB (uV/m) average. 73dB (uV/m) quasi peak, 60dB (uV/m) average. 73dB (uV/m) quasi peak, 60dB (uV/m) average. 1. Initial Report: 789 EMC Test Report 9 Jul 2002.pdf Portable test & measurement equipment that is not capable of operating while being charged is tested to the following immunity requirments: Adapted from IEC 61326-1:2005 Table A.1 Immunity test requirements for portable test and measurement equipment Port Phenomenon Basic standard Test value Criteria ESD IEC 61000-4-2 4 kV/8 kV contact/air B 3 V/m EM Field IEC 61000-4-3 A1 (80 MHz to 1 GHz) Enclosure 3 V/m EM Field IEC 61000-4-3 A1 (1,4 GHz to 2 GHz) 1 V/m EM Field IEC 61000-4-3 A1 (2,0 GHz to 2,7 GHz) 1. See performance criteria defiinitions on following page. 2. Initial Report: 789 EMC Test Report 9 Jul 2002.pdf Pass/Fail Pass2 Pass2 Pass Pass
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Producer : Acrobat Distiller 8.3.1 (Windows) Keywords : EMC template report Company : Fluke Corporation Category : EMC Source Modified : D:20130107211305 Creator Tool : Acrobat PDFMaker 8.1 for Word Modify Date : 2013:01:07 13:14:01-08:00 Create Date : 2013:01:07 13:13:35-08:00 Metadata Date : 2013:01:07 13:14:01-08:00 Document ID : uuid:c67d458b-2404-4be1-9871-c8575e764374 Instance ID : uuid:cd84a419-688f-49f8-a8e0-4980f84e3211 Subject : 2 Format : application/pdf Creator : mmeisner Title : EMCTestReport Description : Fluke EMC Test Report Headline : Fluke EMC Test Report Page Count : 2 Page Layout : OneColumn Author : mmeisnerEXIF Metadata provided by EXIF.tools