Fluke 789 Users Manual EMCReport

2015-09-09

: Fluke Fluke-789-Users-Manual-806298 fluke-789-users-manual-806298 fluke pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

Report # EMC2008Nov17-1420
ELECTROMAGNETIC COMPATIBILITY
TEST CERTIFICATE
for the
Fluke 789
Processmeter
TABL
E
The Fluke 789 was tested to the following standard
at the EMC laboratories of Fluke Corporation.
EN 61326-1 :2006
Class A Emissions and Immunity
The Fluke 789 passes test requirements for equipment used for:
Industrial Locations Controlled EM Environments Portable Equipment
Non-Domestic Use (Class A) Domestic Use (Class B)
Class A equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power
supply network which supplies buildings used for domestic purposes.
Prepared by: 17 Nov 2008
Michael Meisner ______________________________________ Date: _______________________
EMC Technician Specialist
Reviewed by: 17 Nov 2008
Thomas Smith _______________________________________ Date: _______________________
Test Engineer Sr.
Approved by:
Product Evaluation Manager
Division Engineering Manager
I. Test Results
The Fluke 789 Processmeter was tested to the following Electromagnetic Compatibility [EMC] requirements:
Adapted from CISPR 11 Table 2a
Emissions Limits for Class A Equipment
Port Frequency
MHz Limits Standard Pass/Fail
Enclosure 30 to 230 40dB (uV/m) quasi peak, measured at 10 meters. Pass
1
230 to 1000 47dB (uV/m) quasi peak, measured at 10 meters. Pass
1
AC mains 0.15 to 0.5 79dB (uV/m) quasi peak, 66dB (uV/m) average. CISPR 11 N/A
0.5 to 5.0 73dB (uV/m) quasi peak, 60dB (uV/m) average. N/A
5 to 30 73dB (uV/m) quasi peak, 60dB (uV/m) average. N/A
1. Initial Report: 789 EMC Test Report 9 Jul 2002.pdf
Portable test & measurement equipment that is not capable of operating while being charged
is tested to the following immunity requirments:
Adapted from IEC 61326-1:2005 Table A.1
Immunity test requirements for portable test and measurement equipment
Port Phenomenon Basic standard Test value Criteria Pass/Fail
Enclosure
ESD IEC 61000-4-2 4 kV/8 kV contact/air B Pass
2
EM Field IEC 61000-4-3 3 V/m
(80 MHz to 1 GHz) A1 Pass2
EM Field IEC 61000-4-3 3 V/m
(1,4 GHz to 2 GHz) A1 Pass
EM Field IEC 61000-4-3 1 V/m
(2,0 GHz to 2,7 GHz) A1 Pass
1. See performance criteria defiinitions on following page.
2. Initial Report: 789 EMC Test Report 9 Jul 2002.pdf