Fluke 807 0115 Users Manual Datasheet_4xT1_E1
807-0115 to the manual 92c5ec97-8279-4796-8a0a-99ef4be151f0
2015-02-02
: Fluke Fluke-807-0115-Users-Manual-427831 fluke-807-0115-users-manual-427831 fluke pdf
Open the PDF directly: View PDF .
Page Count: 34
Download | |
Open PDF In Browser | View PDF |
Visual UpTime Select ASE model 807-0115 4xT1/E1 i nline probe ASE With LinkSafe capabilities The Visual UpTime® Select™ 4xT1/E1 inline probe The 4xT1/E1 ASE includes LinkSafe™ technology Key features ASE enhances the data analysis functionality of the to protect circuit integrity in case of a power outage • Four management ports Visual UpTime Select system for enterprises with and it also delivers a notification alarm if there is a • MLPPP support on IP Transport software two-to-four T1 or E1 circuits terminating at a single power failure. • Inband management capability location. The ASE provides up to 6.176 Mbps • LinkSafe technology • Power loss detection • Service Level Agreement (SLA) metrics Designed for locations with multiple circuits (T-standard) or 8.192 Mbps (E-standard) of detailed terminating at a single device, the 4xT1/E1 is typi- network traffic analysis and management, while cally deployed as an inline probe between the service maintaining full wire speed pass-through of all provider’s edge device and the customer’s termination traffic. In its initial release, the ASE supports IP equipment. The figure below highlights the multilink • Application analysis capability Transport software over MultiLink Point-to-Point deployment for the 4xT1/E1 ASE. • LMI spoofing Protocol (MLPPP) T1 links. • LAN management port • Realtime events 4xT1/E1 inline probe model 807-0115 front 4xT1/E1 inline probe model model 807-0115 rear Optional LAN Connection Bundled T1 Line WAN 4xT1/E1 inline ASE CPE Router LAN 4xT1/E1 inline probe model 807-0115 position on network Technical Data What are ASEs? 4xT1/E1 inline probe ASE specifcations General Environment Power Requirements T1 Network Interface (Ports 1-4) E1 Network Interface (Ports 1-4) Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) ASEs (Analysis Service Elements) are data Weight 7 lbs. collection and network performance monitor- Data Rate T1: 1.536 Mbps, E1: 1.984 Mbps ing hardware devices placed on a wide area Timing Mode Derived externally from the T1 or E1 network, user interface, or internally from the ASE. network (WAN) or Local Area Network (LAN) Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 80%, noncondensing Input 100 to 240 VAC UpTime Select server and displayed and ana- Frequency 50/60 Hz lyzed from the Visual UpTime Select Web client. Input Current Rating 0.5 amps As a service level management tool, ASEs Line Rate 1.544 Mbps ±50 bps synchronous indicate when services are being met, provide Line Format B8ZS line coding warnings when services start to degrade, and Framing ESF framing formats send alerts when services are not met. Input Signal 0dB to -36dB Output Signal 0, -7.5dB, -15dB, -22.5dB LBO Hardware Warranties Pulse Density AT&T 62411 Enhanced Gold, Bronze, and International Connector 100 ohm 8-pin modular jack—USOC: RJ48C Gold ASE hardware warranty service programs Timing Network or User are available to help you maximize your Channel Selection 1 to 24 channels in any combination investment in Visual UpTime Select. For more Line Rate 2.048 Mbps ±102.4 bps synchronous detailed warranty information, visit: Line Format HDB3 line coding www.flukenetworks.com/visualcustomercare Framing CRC4 or FAS framing formats o o o o o as part of the Visual UpTime Select system, o o o which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual Time Slot 16 CAS, CCS, or Data Ordering Information Input Signal 0dB to -43dB For more details, please contact your Visual Output Signal 0dB UpTime Select authorized reseller or Connector 120 ohm RJ-48C balanced and 75 ohm BNC unbalanced coaxial Fluke Networks Sales at (800) 240-4010 Channel Selection 1-31 (includes channel 16) or 1-15, 17-31 (does not include channel 16) Baud Rate 19200 or 9600 bps Parity 8 data bits, no parity Stop Bit 1 stop bit Electrical Format EIA RS-232, DTE Connector RJ-45 Bite Rate 10 or 100 Mbps Connector 8-pin modular jack: RJ-48 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643418 D-ENG-N Rev A Visual UpTime Select ASE model 807-0113 T1/E1 i nline probe ASE With LinkSafe capabilities The Visual UpTime® Select™ T1/E1 LinkSafe™ inline When configured for use on an E1 network, the ASE Key features probe ASE is deployed inline on a T1 or E1 access line, complies with the physical/electrical characteristics • Inband management capabilities typically between a service provider’s edge device and defined by ITU-T G.703 at 2.048 Megabits per second • LinkSafe technology CSU/DSU. This ASE supports Multi-Protocol software (Mbps). The ASE also complies with the synchronous • Power loss detection for deployment in standard frame relay or HDLC frame structure specifications defined by ITU-T G.704, networks and IP Transport software for deployment including the option to use channel 16 for data or in frame relay or HDLC-based networks that use IP signalling. You can either connect to the E1 network switching. The ASE also includes LinkSafe technology using a 120 ohm balanced cable or BNC coax 75 ohm to protect circuit integrity in case of an ASE outage, unbalanced cables. • Multi-Protocol or IP Transport software • Service Level Agreement (SLA) metrics • Voice over IP (VoIP) analysis capability • Application analysis capability as well as power failure notification. • LMI spoofing • LAN management port • Realtime events T1/E1 inline probe model 807-0113 front view T1/E1 inline probe model model 807-0113 rear view Optional LAN Connection T1/E1 Access Line LAN WAN T1/E1 inline ASE CSU/DSU CPE Router Visual UpTime Select Server T1/E1 inline probe model 807-0113 position on network Technical Data What are ASEs? T1/E1 inline probe ASE specifcations General Environment Power Requirements T1 Network Interface E1 Network Interface Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) ASEs (Analysis Service Elements) are data Weight 2.10 lbs. collection and network performance monitor- Data Rate 1.544 Mbps synchronous ing hardware devices placed on a wide area Timing Mode Derived externally from the T1 or E1 network, user interface, or internally from the ASE. network (WAN) or Local Area Network (LAN) Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 80%, noncondensing Input 100 to 240 VAC UpTime Select server and displayed and ana- Frequency 50/60 Hz lyzed from the Visual UpTime Select Web client. Input Current Rating 0.5 amps As a service level management tool, ASEs Line Rate 1.544 Mbps ±50 bps synchronous indicate when services are being met, provide Line Format AMI or B9ZS line coding warnings when services start to degrade, and Framing ESF or D4 framing formats send alerts when services are not met. Input Signal 0dB to -36dB Output Signal 0, -7.5dB, -15dB, -22.5dB LBO Hardware Warranties Pulse Density AT&T 62411 Enhanced Gold, Bronze, and International Connector 8-pin modular jack—USOC: RJ48C Gold ASE hardware warranty service programs Timing Network, User, or Internal are available to help you maximize your Channel Selection 1 to 24 channels in any combination investment in Visual UpTime Select. For more Line Rate 2.048 Mbps ±102.4 bps synchronous detailed warranty information, visit: Line Format HDB3 or AMI line coding www.flukenetworks.com/visualcustomercare Framing CRC4 or FAS framing formats o o o o o as part of the Visual UpTime Select system, o o o which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual Time Slot 16 CAS, CCS, or Data Ordering Information Input Signal 0dB to -43dB For more details, please contact your Visual Output Signal 0dB to LBO UpTime Select authorized reseller or Connector RJ-45 (100 ohm balanced) or BNC (75 ohm unbalanced) Fluke Networks Sales at (800) 240-4010 Channel Selection 1-31 (includes channel 16 or 1-15, 17-31 (does not include channel 16) Baud Rate 19200 or 9600 bps Parity 8 data bits, no parity Stop Bit 1 stop bit Electrical Format EIA RS-232, DTE Connector RJ-45 Bite Rate 10 or 100 Mbps Connector 8-pin modular jack: RJ-48 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643532 D-ENG-N Rev A Visual UpTime Select ASE model 807-0120 10/100 Ethernet i nline ASE LE With LinkSafe capabilities The Visual UpTime® Select™ 10/100 Ethernet line between LAN devices, such as the LAN switch Key features inline ASE LE enhances the analysis functionality and router (see figure). Other options include posi- • Inline or SPAN mode deployment of the Visual UpTime Select system for Ethernet tioning the ASE on the Ethernet segment between a • LinkSafe technology networks. The ASE provides up to 6 Mbps of detailed subscriber’s router and a Network Terminating Unit • IP Transport or LAN Visibility software network traffic analysis and management, while (NTU) such as a DSL modem or a Service Provider maintaining full wire speed pass-through of all traf- switch (Ethernet as WAN access), or connecting the fic. It supports both IP Transport and LAN Visibility ASE to a router or switch SPAN port. • Voice over IP (VoIP) analysis capability • Application analysis capability • LAN management port software When deployed inline, the ASE includes The LAN Visibility Ethernet ASE is deployed on LinkSafe™ technology to protect circuit integrity if the LAN. The inline LAN Visibility ASE collects and • Power loss detection in case of an ASE outage, as well as power failure displays application flow traffic on the LAN between • Realtime events notification. clients and application server. In contrast, the IP Designed for business class DSL and cable, the Transport ASE is designed to display only traffic to or 10/100 Ethernet inline ASE LE has a wide variety of from the WAN, and ignore local traffic (such as be- deployment options. The IP Transport Ethernet ASE is tween a client and an Internet or application server). typically deployed as an inline probe on the access Ethernet inline probe model 807-0120 front view Client Access Line(s) Wide Area Network NTU Customer IP Transport LAN Switch device Edge Router Ethernet ASE Server LAN LAN Visibility Ethernet ASE Ethernet inline probe model 807-0120 deployed inline IP Transport and on LAN in LAN Visibility mode Technical Data What are ASEs? Ethernt inline probe ASE specifcations General Environment Dimensions 7.5” (19.1 cm) x 6” (15.2 cm) x 1.5” (3.8 cm) ASEs (Analysis Service Elements) are data Weight 2.10 lbs. collection and network performance monitor- Maximum Data Rate 6 Mbps Operating Temperature o ing hardware devices placed on a wide area o o o 0 to +40 C (+32 to +104 F) o o o o network (WAN) or Local Area Network (LAN) Storage Temperature -20 to +55 C (-4 to +131 ×F) as part of the Visual UpTime Select system, Clearance Requirement Minimum of 3” (7.62 cm) space on sides. which offers in-depth, real-time, and historical Input 100 to 240 VAC visibility into the performance of your Frequency 50/60 Hz applications infrastructure. In the system, Input Current Rating 0.5 amps data gathered by ASEs is stored in the Visual LAN and WAN Ethernet Interface Bit Rate 10/100 Mbps Connector 8-pin modular jack: RJ-45 Serial Port Interface Baud Rate 19200 or 9600 bps Parity 8 data bits, no parity Stop Bit 1 stop bit Electrical Format EIA RS-232, DTE Connector RJ-45 Power Requirements UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client. As a service level management tool, ASEs indicate when services are being met, provide warnings when services start to degrade, and send alerts when services are not met. Hardware Warranties Enhanced Gold, Bronze, and International Gold ASE hardware warranty service programs are available to help you maximize your investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Ethernet inline probe model model 807-0120 rear view Ordering Information For more details, please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643441 D-ENG-N Rev A Visual UpTime Select ASE model 807-0122 10/100 Ethernet i nline ASE With LinkSafe capabilities The Visual UpTime® Select™ 10/100 Ethernet line between LAN devices, such as the LAN switch Key features inline ASE enhances the analysis functionality of the and router (see figure). Other options include posi- • Inline or SPAN mode deployment Visual UpTime Select system for Ethernet networks. tioning the ASE on the Ethernet segment between a • LinkSafe technology The ASE provides up to 100 Mbps of detailed network subscriber’s router and a Network Terminating Unit • IP Transport or LAN Visibility software traffic analysis and management, while maintaining (NTU) such as a DSL modem or a Service Provider full wire speed pass-through of all traffic. It supports switch (Ethernet as WAN access), or connecting the both IP Transport and LAN Visibility software When ASE to a router or switch SPAN port. • Voice over IP (VoIP) analysis capability • Application analysis capability • Power loss detection • LAN management port • Realtime events deployed inline, the ASE includes LinkSafe™ technol- The LAN Visibility Ethernet ASE is deployed on ogy to protect circuit integrity if in case of an ASE the LAN. The inline LAN Visibility ASE collects and outage, as well as power failure notification. displays application flow traffic on the LAN between Designed for business class DSL and cable, the clients and application server. In contrast, the IP 10/100 Ethernet inline ASE has a wide variety of Transport ASE is designed to display only traffic to or deployment options. The IP Transport Ethernet ASE is from the WAN, and ignore local traffic (such as be- typically deployed as an inline probe on the access tween a client and an Internet or application server). Ethernet inline probe model 807-0122 front view Client Access Line(s) Wide Area Network NTU Customer IP Transport LAN Switch device Edge Router Ethernet ASE Server LAN LAN Visibility Ethernet ASE Ethernet inline probe model 807-0122 deployed inline IP Transport and on LAN in LAN Visibility mode Technical Data What are ASEs? Ethernt inline probe ASE specifcations General Environment Dimensions 7.5” (19.1 cm) x 6” (15.2 cm) x 1.5” (3.8 cm) ASEs (Analysis Service Elements) are data Weight 2.10 lbs. collection and network performance monitor- Maximum Data Rate 100 Mbps Operating Temperature o ing hardware devices placed on a wide area o o o 0 to +40 C (+32 to +104 F) o o o o network (WAN) or Local Area Network (LAN) Storage Temperature -20 to +55 C (-4 to +131 ×F) as part of the Visual UpTime Select system, Clearance Requirement Minimum of 3” (7.62 cm) space on sides. which offers in-depth, real-time, and historical Input 100 to 240 VAC visibility into the performance of your Frequency 50/60 Hz applications infrastructure. In the system, Input Current Rating 0.5 amps data gathered by ASEs is stored in the Visual LAN and WAN Ethernet Interface Bit Rate 10/100 Mbps Connector 8-pin modular jack: RJ-45 Serial Port Interface Baud Rate 19200 or 9600 bps Parity 8 data bits, no parity Stop Bit 1 stop bit Electrical Format EIA RS-232, DTE Connector RJ-45 Power Requirements UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client. As a service level management tool, ASEs indicate when services are being met, provide warnings when services start to degrade, and send alerts when services are not met. Hardware Warranties Enhanced Gold, Bronze, and International Gold ASE hardware warranty service programs are available to help you maximize your investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Ethernet inline probe model model 807-0122 rear view Ordering Information For more details, please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643434 D-ENG-N Rev A Visual UpTime Select ASE model 807-0220 10/100/1000 Ethernet ASE With SPAN mode capabilities The Visual UpTime® Select™ 10/100/1000 Ethernet The LAN Visibility Ethernet ASE is deployed on the Key features ASE enhances the analysis functionality of Visual LAN. The ASE collects and displays application flow • 500 MB of total analysis UpTime Select for Ethernet networks. The ASE traffic on the LAN between clients and application • SPAN mode deployment provides up to 500 Mbps of detailed network traffic server. In contrast, the IP Transport ASE is designed • Deployable in DS3, NxDS3, Fractional analysis and management, while maintaining full wire to display only traffic to or from the WAN, and ignore speed pass-through of all traffic. It supports both IP local traffic (such as between a client and an Inter- Transport and LAN Visibility software net or application server). OC3, and Ethernet to Premises topologies • IP Transport or LAN Visibility software • Voice over IP (VoIP) analysis capability Designed for business class DSL and cable, the 10/100/1000 Ethernet ASE has a wide variety of • Application analysis capability deployment options. The IP Transport Ethernet ASE is • LAN management port deployed off a LAN switch SPAN port (see figure). • Realtime events Ethernet inline probe model 807-0220 front view Ethernet inline probe model model 807-0220 rear view Customer Edge Router LAN Switch Wide Area Network SPAN port Ethernet ASE Ethernet probe model 807-0220 deployed on a LAN switch SPAN port Technical Data LAN What are ASEs? Ethernt inline probe ASE specifcations General Environment Dimensions 17.3” (43.9 cm) x 12” (30.5 cm) x 3.5” (8.9 cm) ASEs (Analysis Service Elements) are data Weight 10.45 lbs. collection and network performance monitor- Maximum Data Rate 500 Mbps Operating Temperature o ing hardware devices placed on a wide area o o o 0 to +40 C (+32 to +104 F) o o o o network (WAN) or Local Area Network (LAN) Storage Temperature -20 to +55 C (-4 to +131 ×F) as part of the Visual UpTime Select system, Clearance Requirement Minimum of 3” (7.62 cm) space on sides. which offers in-depth, real-time, and historical Input 100 to 240 VAC visibility into the performance of your Frequency 50/60 Hz applications infrastructure. In the system, Input Current Rating 0.5 amps data gathered by ASEs is stored in the Visual LAN and WAN Ethernet Interface Bit Rate 10/100/1000 Mbps Connector 8-pin modular jack: RJ-45 Serial Port Interface Baud Rate 19200 or 9600 bps Parity 8 data bits, no parity Stop Bit 1 stop bit Electrical Format EIA RS-232, DTE Connector 9-pin D, male per EIA-574 Power Requirements UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client. As a service level management tool, ASEs indicate when services are being met, provide warnings when services start to degrade, and send alerts when services are not met. Hardware Warranties Enhanced Gold, Bronze, and International Gold ASE hardware warranty service programs are available to help you maximize your investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Ordering Information For more details, please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643429 D-ENG-N Rev A Visual UpTime Select ASE model 807-0106 HSSI i nline probe ASE With LinkSafe capabilities The Visual UpTime® Select™ HSSI LinkSafe™ inline The ASE also includes LinkSafe technology to protect Key features probe ASE is deployed inline on a High Speed Serial circuit integrity in case of an ASE outage, as well as • Inband management capabilities Interface (HSSI) access line, typically between a power failure notification. • LinkSafe technology CSU/DSU and customer edge router. It is capable of • Power loss detection monitoring traffic flowing through a bi-directional minal Equipment (DTE) for monitoring traffic to the HSSI connection at data rates up to 44.7 Mbps. network and Data Communication Equipment (DCE) • Multi-Protocol or IP Transport software • Service Level Agreement (SLA) metrics • Application analysis capability • LMI spoofing The HSSI ASE has two HSSI interfaces, Data Ter- The HSSI ASE supports Multi-Protocol software for for monitoring traffic from the network. Because of deployment in standard frame relay or HDLC networks its high speed capabilities, a HSSI ASE can support and IP Transport software for deployment in frame data passed through the CSU/DSU from NxT1 relay or HDLC-based networks that use IP switching. and DS3 lines. • LAN management port • Realtime events HSSI inline probe model 807-0106 front view HSSI inline probe model model 807-0106 rear view Optional LAN Connection Access Line LAN WAN CSU/DSU Inline ASE CPE Router Visual UpTime Select Server HSSI inline probe model 807-0106 position on network Technical Data What are ASEs? HSSI inline probe ASE specifcations Dimensions 17.3” (43.9 cm) x 12” (30.5 cm) x 3.5” (8.9 cm) ASEs (Analysis Service Elements) are data Weight 10.45 lbs. collection and network performance monitor- Data Rate 0 to 44.736 Mbps synchronous ing hardware devices placed on a wide area Timing Mode RD: Always synchronous with SCR SD: Synchronous with SCT or SCTE network (WAN) or Local Area Network (LAN) Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 80%, noncondensing Input 100 to 240 VAC UpTime Select server and displayed and ana- Frequency 50/60 Hz lyzed from the Visual UpTime Select Web client. Input Current Rating 1 amp As a service level management tool, ASEs HSSI Interface Configuration Two HSSI interfaces: one DTE and one DCE for monitoring to-network and from-network traffic. indicate when services are being met, provide Serial Port Interface Baud Rate 19200 or 9600 bps Parity 8 data bits, no parity Stop Bit 1 stop bit Hardware Warranties Electrical Format EIA RS-232, DTE Enhanced Gold, Bronze, and International Connector 9-pin D, male per EIA-574 Gold ASE hardware warranty service programs Bite Rate 10 or 100 Mbps are available to help you maximize your Connector 8-pin modular jack: RJ-48 investment in Visual UpTime Select. For more General Environment Power Requirements Ethernet 10/100BaseT Interface o o o o o as part of the Visual UpTime Select system, o o o which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual warnings when services start to degrade, and send alerts when services are not met. detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Ordering Information For more details, please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643476 D-ENG-N Rev A Visual UpTime Select ASE model 807-0104 V.35 i nline probe ASE With LinkSafe capabilities The Visual UpTime® Select™ V.35 LinkSafe™ inline The V.35 inline probe ASE supports V.35 connectiv- Key features probe ASE is deployed inline on a T1 access line, ity through a V.35 Data Terminal Equipment (DTE) • Inband management capabilities typically between a CSU/DSU and customer premises interface on the network side and Data Communica- • LinkSafe technology equipment. This ASE supports Multi-Protocol software tions Equipment (DCE) interface on the user side. • Multi-Protocol or IP Transport software for deployment in standard frame relay or HDLC • Service Level Agreement (SLA) metrics • Voice over IP (VoIP) analysis capability The ASE operates at data rates up to 2.048 Mbps, networks and IP Transport software for deployment deriving timing from the network-side and sourcing in frame relay or HDLC-based networks that use IP timing on the user side. It also includes LinkSafe switching. technology to protect circuit integrity in case of an • Application analysis capability ASE outage, as well as power failure notification. • LMI spoofing • LAN management port • Power loss detection • Realtime events V.35 inline probe model 807-0104 front view V.35 inline probe model model 807-0104 rear view Optional LAN Connection Access Line LAN WAN CSU/DSU Inline ASE CPE Router Visual UpTime Select Server V.35 inline probe model 807-0104 position on network Technical Data What are ASEs? V.35 inline probe ASE specifcations General Environment Power Requirements V.35 User Interface (DCE) V.35 Network Interface (DTE) Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) Plastic case with internal power supply ASEs (Analysis Service Elements) are data Weight 2.10 lbs. ing hardware devices placed on a wide area Data Rate 0 to 2.048 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode RD: Always synchronous with SCR SD: Synchronous with SCT or SCTE as part of the Visual UpTime Select system, Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 80%, noncondensing Input 100 to 240 VAC lyzed from the Visual UpTime Select Web client. Frequency 50/60 Hz As a service level management tool, ASEs Input Current Rating 0.5 amps indicate when services are being met, provide Configuration DCE for interfacing with DTE warnings when services start to degrade, and Data and Clock Leads ITU-T V.35 Signaling Leads EIA RS-232 (ITU-T V.28) Connector Female 34-pin V.35 connector Hardware Warranties Signaling RTS, DTR Enhanced Gold, Bronze, and International Configuration DTE for interfacing with DCE Gold ASE hardware warranty service programs Data and Clock Leads ITU-T V.35 are available to help you maximize your Signaling Leads EIA RS-232 (ITU-T V.28) Connector Female 34-pin V.35 connector Signaling CTS, RLSD, DSR Baud Rate 19200 or 9600 bps Parity 8 data bits, no parity Ordering Information Stop Bit 1 stop bit For more details, please contact your Visual Electrical Format EIA RS-232, DTE Connector RJ-45 Bite Rate 10 or 100 Mbps Connector 8-pin modular jack: RJ-48 o o o o o o o o collection and network performance monitor- which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and ana- send alerts when services are not met. investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643465 D-ENG-N Rev A Visual UpTime Select ASE model 807-0105 X.21 i nline probe ASE With LinkSafe capabilities The Visual UpTime® Select™ X.21 LinkSafe™ inline The ASE supports X.21 connectivity through a X.21 Key features probe ASE is deployed inline on an access line, typical- Data Terminal Equipment (DTE) interface on the • Inband management capabilities ly between a CSU/DSU and customer premises equip- network side and Data Communications Equipment • LinkSafe technology ment (CPE). It supports Multi-Protocol software for (DCE) interface on the user side. • Multi-Protocol or IP Transport software deployment in standard frame relay or HDLC networks • Service Level Agreement (SLA) metrics • Voice over IP (VoIP) analysis capability The ASE operates at data rates up to 2.048 Mbps, and IP Transport software for deployment in frame deriving timing from the network-side and sourcing relay or HDLC-based networks that use IP switching. timing on the user side. It also includes LinkSafe technology to protect circuit integrity in case of an • Application analysis capability ASE outage, as well as power failure notification. • LMI spoofing • LAN management port • Power loss detection • Realtime events X.21 inline probe model 807-0105 front view X.21 inline probe model model 807-0105 rear view Optional LAN Connection Access Line LAN WAN CSU/DSU Inline ASE CPE Router Visual UpTime Select Server X.21 inline probe model 807-0105 position on network Technical Data What are ASEs? X.21 inline probe ASE specifcations General Environment Power Requirements X.21 User Interface (DCE) X.21 Network Interface (DTE) Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) Plastic case with internal power supply ASEs (Analysis Service Elements) are data Weight 2.10 lbs. ing hardware devices placed on a wide area Data Rate 0 to 2.048 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode RD: Always synchronous with SCR SD: Synchronous with SCT or SCTE as part of the Visual UpTime Select system, Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 80%, noncondensing Input 100 to 240 VAC lyzed from the Visual UpTime Select Web client. Frequency 50/60 Hz As a service level management tool, ASEs Input Current Rating 0.5 amps indicate when services are being met, provide Configuration DCE for interfacing with DTE warnings when services start to degrade, and Data and Clock Leads ITU-CCITT X.21 Signaling Leads ITU-CCITT X.21 Connector Female 15-pin X.21 connector Hardware Warranties Signaling Indicate: Clear to Send control signal to the user interface. Received and terminated by the ASE. Enhanced Gold, Bronze, and International Configuration DTE for interfacing with DCE Data and Clock Leads ITU-CCITT X.21 Signaling Leads ITU-CCITT X.21 Connector Female 15-pin X.21 connector Signaling Control: Request to Send control signal from the user interface. On while power is applied by the ASE. o o o o o o o o collection and network performance monitor- which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and ana- send alerts when services are not met. Gold ASE hardware warranty service programs are available to help you maximize your investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Ordering Information Baud Rate 19200 or 9600 bps For more details, please contact your Visual Parity 8 data bits, no parity UpTime Select authorized reseller or Stop Bit 1 stop bit Fluke Networks Sales at (800) 240-4010 Electrical Format EIA RS-232, DTE or (301) 296-2300. Connector RJ-45 Bite Rate 10 or 100 Mbps Connector 8-pin modular jack: RJ-48 N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643152 D-ENG-N Rev A Visual UpTime Select ASE model 807-0200 DS3 i nline probe ASE With LinkSafe capabilities The Visual UpTime® Select™ DS3 LinkSafe™ inline The DS3 inline probe ASE is designed for deploy- Key features probe ASE complies with Class A standards for ment at the network demarcation point between a • Inband management capabilities countries using DS3 ATM lines (U.S. and Canada) and subscriber’s CPE and the WAN. It can be deployed in • LinkSafe technology supports digital transmission at the DS3 rate of 44 ATM and mixed frame relay-ATM environments. The • Multi-Protocol or IP Transport software Mbps. This ASE supports Multi-Protocol software for figure below shows the ASE positioned at the edge of deployment in standard ATM networks and IP Trans- an inter-worked frame relay-to-ATM network, allowing port software for deployment in ATM-based networks for SLA messaging between a frame relay DLCI and an that use IP switching. The ASE also includes LinkSafe ATM VPI/VCI. • Service Level Agreement (SLA) metrics • Application analysis capability • LAN management port • Realtime events technology to protect circuit integrity in case of an ASE outage, as well as power failure notification. DS3 inline probe model 200 front view DS3 inline probe model 200 rear view LAN Branch ASEs Frame to ATM Interworking T1 Frame Network ATM ASE ATM Network DS3 inline probe model 200 on ATM/Frame network Technical Data CPE Router Visual UpTime Select server What are ASEs? DS3 inline probe ASE specifcations General Environment Power Requirements Network Interface Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 1 EIA unit (1.75”) high x 19” wide rack-mountable chassis ASEs (Analysis Service Elements) are data Weight 10 lbs. ing hardware devices placed on a wide area Data Rate to 45 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the network. Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating/Storage Humidity 10% to 90% non-condensing Input 100 to 240 VAC Frequency 50/60 Hz Input Current Rating 0.5 amps Line Rate 44.736 Mbps As a service level management tool, ASEs Cell Delineation HEC or PLCP indicate when services are being met, provide Cell Scrambler Enable or Disable warnings when services start to degrade, and Line Build Out Long = more than 225 feet. Short = 225 feet or less. send alerts when services are not met. Connector 4 BNC (75 ohm), Network Tx and Rx, CPE Tx and Rx Baud Rate 57600, 19200, or 9600 bps Parity 8 data bits, no parity Enhanced Gold, Bronze, and International Stop Bit 1 stop bit Gold ASE hardware warranty service programs Electrical Format EIA RS-232, DTE are available to help you maximize your Connector 9-pin D, male per EIA-574 investment in Visual UpTime Select. For more Bite Rate 10 or 100 Mbps detailed warranty information, visit: Connector 8-pin modular jack: RJ-48 www.flukenetworks.com/visualcustomercare o o o o o collection and network performance monitor- as part of the Visual UpTime Select system, o o o which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client. Hardware Warranties Ordering Information For more details, please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643490 D-ENG-N Rev A Visual UpTime Select ASE model 807-0201 E3 i nline probe ASE With LinkSafe capabilities The Visual UpTime® Select™ E3 LinkSafe™ inline The E3 inline probe ASE is designed for deploy- Key features probe ASE complies with Class A standards for ment at the network demarcation point between a • Inband management capabilities countries using E3 ATM lines and supports digital subscriber’s CPE and the WAN. It can be deployed in • LinkSafe technology transmission at the E3 rate of 34 Mbps. This ASE ATM and mixed frame relay-ATM environments. The • Multi-Protocol or IP Transport software supports Multi-Protocol software for deployment in figure below shows the ASE positioned at the edge of standard ATM networks and IP Transport software an inter-worked frame relay-to-ATM network, allowing for deployment in ATM-based networks that use IP for SLA messaging between a frame relay DLCI and an switching. The ASE also includes LinkSafe technology ATM VPI/VCI. • Service Level Agreement (SLA) metrics • Application analysis capability • LAN management port • Realtime events to protect circuit integrity in case of an ASE outage, as well as power failure notification. E3 inline probe model 201 front view E3 inline probe model 201 rear view LAN Branch ASEs Frame to ATM Interworking T1 Frame Network ATM ASE ATM Network E3 inline probe model 201 on ATM/Frame network Technical Data CPE Router Visual UpTime Select server What are ASEs? E3 inline probe ASE specifcations General Environment Power Requirements Network Interface Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 1 EIA unit (1.75”) high x 19” wide rack-mountable chassis ASEs (Analysis Service Elements) are data Weight 10 lbs. ing hardware devices placed on a wide area Data Rate to 34 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the network. Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating/Storage Humidity 10% to 90% non-condensing Input 100 to 240 VAC Frequency 50/60 Hz Input Current Rating 0.5 amps Line Rate 34.368 Mbps As a service level management tool, ASEs Cell Delineation HEC or PLCP indicate when services are being met, provide Cell Scrambler Enable or Disable warnings when services start to degrade, and Connector 4 BNC (75 ohm), Network Tx and Rx, CPE Tx and Rx send alerts when services are not met. Baud Rate 57600, 19200, or 9600 bps Parity 8 data bits, no parity Stop Bit 1 stop bit Enhanced Gold, Bronze, and International Electrical Format EIA RS-232, DTE Gold ASE hardware warranty service programs Connector 9-pin D, male per EIA-574 are available to help you maximize your Bite Rate 10 or 100 Mbps investment in Visual UpTime Select. For more Connector 8-pin modular jack: RJ-48 o o o o o collection and network performance monitor- as part of the Visual UpTime Select system, o o o which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client. Hardware Warranties detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Ordering Information For more details, please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643483 D-ENG-N Rev A Visual UpTime Select ASE model 807-0202 OC-3c/STM-1 i nline probe ASE Single mode with LinkSafe capabilities The Visual UpTime® Select™ OC-3c/STM-1 LinkSafe™ The OC-3c/STM-1 inline probe ASE is designed Key features inline probe ASE supports single mode ATM OC-3c for deployment at the network demarcation point • Inband management capabilities physical lines, with SONET and SDH standards, at between a subscriber’s CPE and the WAN. It can be • LinkSafe technology speeds up to 155 Mbps. This ASE supports Multi-Proto- deployed in ATM and mixed frame relay-ATM environ- • Multi-Protocol or IP Transport software col software for deployment in standard ATM networks ments. The figure below shows the ASE positioned and IP Transport software for deployment in ATM-based at the edge of an inter-worked frame relay-to-ATM networks that use IP switching. The ASE also includes network, allowing for SLA messaging between a frame LinkSafe technology to protect circuit integrity in case relay DLCI and an ATM VPI/VCI. • Service Level Agreement (SLA) metrics • Application analysis capability • LAN management port of an ASE outage, as well as power failure notification. • Realtime events OC-3c inline probe model 202 front view OC-3c inline probe model 202 rear view LAN Branch ASEs Frame to ATM Interworking OC-3c ATM ASE T1 Frame Network ATM Network OC-3c inline probe model 202 on ATM/Frame network Technical Data CPE Router Visual UpTime Select server What are ASEs? OC-3c inline probe ASE specifcations General Environment Power Requirements Network Interface Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 1 EIA unit (1.75”) high x 19” wide rack-mountable chassis ASEs (Analysis Service Elements) are data Weight 10 lbs. ing hardware devices placed on a wide area Data Rate to 155 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the network. Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating/Storage Humidity 10% to 90% non-condensing Input 100 to 240 VAC Frequency 50/60 Hz Input Current Rating 0.5 amps Bypass 5 volt 1 amp DC As a service level management tool, ASEs Line Rate 155.52 Mbps indicate when services are being met, provide Line Mode SONET or SDH warnings when services start to degrade, and Cell Delineation HEC send alerts when services are not met. Cell Scrambler Enable or Disable Connectors 2 Sff Duplex-LC, Network Tx and Rx, CPE Tx and Rx Wavelength 1274 nm/1356 nm Enhanced Gold, Bronze, and International Tx Average Output Power -11dBm (typical) Measured with single mode cable Gold ASE hardware warranty service programs Rx Sensitivity -33dBm (typical) are available to help you maximize your Baud Rate 57600, 19200, or 9600 bps investment in Visual UpTime Select. For more Parity 8 data bits, no parity detailed warranty information, visit: Stop Bit 1 stop bit www.flukenetworks.com/visualcustomercare Electrical Format EIA RS-232, DTE Connector 9-pin D, male per EIA-574 Ordering Information Bite Rate 10 or 100 Mbps For more details, please contact your Visual Connector 8-pin modular jack: RJ-48 o o o o o collection and network performance monitor- as part of the Visual UpTime Select system, o o o which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client. Hardware Warranties UpTime Select authorized reseller or Fluke Networks Sales at (800) 240-4010 Compliant with Bellcore GR-253 CORE and ITE G.957 standards or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643526 D-ENG-N Rev A Visual UpTime Select ASE model 807-0203 OC-3c/STM-1 i nline probe ASE Multimode with LinkSafe capabilities The Visual UpTime® Select™ OC-3c/STM-1 LinkSafe™ The OC-3c/STM-1 inline probe ASE is designed Key features inline probe ASE supports multimode ATM OC-3c for deployment at the network demarcation point • Inband management capabilities physical lines, with SONET and SDH standards, at between a subscriber’s CPE and the WAN. It can be • LinkSafe technology speeds up to 155 Mbps. This ASE supports Multi- deployed in ATM and mixed frame relay-ATM environ- • Multi-Protocol or IP Transport software Protocol software for deployment in standard ATM ments. The figure below shows the ASE positioned networks and IP Transport software for deployment in at the edge of an inter-worked frame relay-to-ATM ATM-based networks that use IP switching. The ASE network, allowing for SLA messaging between a frame also includes LinkSafe technology to protect circuit relay DLCI and an ATM VPI/VCI. • Service Level Agreement (SLA) metrics • Application analysis capability • LAN management port • Realtime events integrity in case of an ASE outage, as well as power failure notification. OC-3c inline probe model 203 front view OC-3c inline probe model 203 rear view LAN Branch ASEs Frame to ATM Interworking OC-3c ATM ASE T1 Frame Network ATM Network OC-3c inline probe model 203 on ATM/Frame network Technical Data CPE Router Visual UpTime Select server What are ASEs? OC-3c inline probe ASE specifcations General Environment Power Requirements Network Interface Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 1 EIA unit (1.75”) high x 19” wide rack-mountable chassis ASEs (Analysis Service Elements) are data Weight 10 lbs. ing hardware devices placed on a wide area Data Rate to 155 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the network. Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating/Storage Humidity 10% to 90% non-condensing Input 100 to 240 VAC Frequency 50/60 Hz Input Current Rating 0.5 amps Bypass 5 volt 1 amp DC As a service level management tool, ASEs Line Rate 155.52 Mbps indicate when services are being met, provide Line Mode SONET or SDH warnings when services start to degrade, and Cell Delineation HEC send alerts when services are not met. Cell Scrambler Enable or Disable Connectors 2 Sff Duplex-LC, Network Tx and Rx, CPE Tx and Rx Wavelength 1270 nm/1380 nm Tx Average Output Power -16dBm (typical) Measured with 62.5µ/120 Multimedia cable Gold ASE hardware warranty service programs Rx Sensitivity -33dBm (typical) investment in Visual UpTime Select. For more Baud Rate 57600, 19200, or 9600 bps detailed warranty information, visit: Parity 8 data bits, no parity www.flukenetworks.com/visualcustomercare Stop Bit 1 stop bit o o o o o collection and network performance monitor- as part of the Visual UpTime Select system, o o o which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client. Hardware Warranties Enhanced Gold, Bronze, and International are available to help you maximize your Electrical Format EIA RS-232, DTE Ordering Information Connector 9-pin D, male per EIA-574 For more details, please contact your Visual Bite Rate 10 or 100 Mbps UpTime Select authorized reseller or Connector 8-pin modular jack: RJ-48 Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643515 D-ENG-N Rev A Visual UpTime Select ASE model 807-0109 T1 CSU/DSU ASE With DSX-1, Drop-and-Insert capabilities The Visual UpTime® Select™ T1 CSU/DSU ASE is In addition to performing standard CSU/DSU Key features deployed on a T1 access line at the demarcation point functions—such as BER tests, loopbacks, and power • Inband management capabilities between the provider network and customer premises. failure detection—the ASE is capable of inserting • Multi-Protocol or IP Transport software It supports full and fractional (FT1) T1 networks and management traffic. • Service Level Agreement (SLA) metrics provides connectivity through V.35 and additional • Drop-and-Insert capabilities through DSX port • Voice over IP (VoIP) analysis capability • Application analysis capability digital cross connect signal (DSX-1) interfaces. The ASE supports Multi-Protocol software for deploy- The ASE’s “drop-and-insert” feature provides a secondary DSX-1 port that can connect to a Private Branch Exchange at a customer’s site. T1 Timeslots ment in standard frame relay or HDLC networks and can be segmented for a PBX on the same circuit car- IP Transport software for deployment in frame relay or rying data traffic (see figure). HDLC-based networks that use IP switching. • LMI spoofing • LAN management port • Power loss detection • Realtime events T1 CSU/DSU model 807-0109 front view T1 CSU/DSU model 807-0109 rear view Wide Area Network T1 Access Line CSU/DSU ASE Optional LAN Connection PBX PBX Telephone Telephone T1 CSU/DSU model 807-0109 position on network Technical Data V.35 Line Visual UpTime Select Server What are ASEs? T1 CSU/DSU ASE specifcations General Environment Power Requirements T1 Network Interface Network DTE Interface (Data Port) DSX-1 Interface Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) Plastic case with internal power supply. ASEs (Analysis Service Elements) are data Weight 2.10 lbs. ing hardware devices placed on a wide area Data Rate 1.544 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the T1 network or DSX-1 interface, or internally from the ASE. as part of the Visual UpTime Select system, Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 90%, noncondensing Input 100 to 120 VAC lyzed from the Visual UpTime Select Web client. Frequency 50/60 Hz As a service level management tool, ASEs Input Current Rating 0.5 amps indicate when services are being met, provide Line Rate 1.544 Mbps ±50 bps synchronous warnings when services start to degrade, and Line Format AMI or B9ZS line coding Framing ESF or D4 framing formats ESF FDL ANSI T1.403, AT&T TR54016, Both, or None Hardware Warranties Input Signal 0dB to -36dB Enhanced Gold, Bronze, and International Output Signal 0, -7.5dB, -15dB, -22.5dB LBO Gold ASE hardware warranty service programs Pulse Density AT&T 62411 are available to help you maximize your Connector 8-pin modular jack—USOC: RJ48C Timing Loop, DSX-1, or Internal Channel Selection 1 to 24 channels in any combination Configuration DCE for interfacing with DTE Data and Clock Leads ITU-T V.35 Ordering Information Signaling Leads EIA RS-232 (ITU-T V.28) For more details, please contact your Visual Data Rates 56 kbps x N or 64 kbps x N (N = 1 through 24) UpTime Select authorized reseller or HDLC Inversion Selectable V.35 data inversion Transmit Timing Basis Network selected-source timing Receive Timing Basis SCT, inverted SCT, SCTE Receive Line Data Not Valid RLSD, CTS Connector Female 34-pin V.35 connector Line Rate 1.544 Mbps ±50 bps o o o o o o o o collection and network performance monitor- which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and ana- send alerts when services are not met. investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. Line Format AMI or B8ZS Framing ESF or D4 (SF) Input Signal -1dB to -11dB Line Equalization 0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft Connector RJ-45 Channel Selection 1 to 24 channels in any combination Specifications 19200 or 9600 bps baud rate, 8 data bits no parity, 1 stop bit, EIA RS-232 DTE electrical format, RJ-45 connector Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Bite Rate 10 or 100 Mbps Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. Connector 8-pin modular jack: RJ-48 N E T W O R K S U P E R V I S I O N ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643395 D-ENG-N Rev A Visual UpTime Select ASE model 807-0110 T1 CSU/DSU ASE The Visual UpTime® Select™ T1 CSU/DSU ASE is IP Transport software for deployment in frame relay or Key features deployed on a T1 access line at the demarcation point • Inband management capabilities between the provider network and customer premises. • Multi-Protocol or IP Transport software It supports full and fractional (FT1) T1 networks and functions—such as BER tests, loopbacks, and power • Service Level Agreement (SLA) metrics provides connectivity through V.35 interface. failure detection—the ASE is capable of inserting • Voice over IP (VoIP) analysis capability • Application analysis capability The ASE supports Multi-Protocol software for deploy- HDLC-based networks that use IP switching. In addition to performing standard CSU/DSU management traffic. ment in standard frame relay or HDLC networks and • LMI spoofing • LAN management port • Power loss detection • Realtime events T1 CSU/DSU model 807-0110 front view T1 CSU/DSU model 807-0110 rear view Demarcation Point Wide Area Network T1 Access Line V.35 Line CSU/DSU ASE Optional LAN Connection T1 CSU/DSU model 807-0110 position on network Technical Data Visual UpTime Select Server What are ASEs? T1 CSU/DSU ASE specifcations General Environment Power Requirements T1 Network Interface Network DTE Interface (Data Port) Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) Plastic case with internal power supply. ASEs (Analysis Service Elements) are data Weight 2.10 lbs. ing hardware devices placed on a wide area Data Rate 1.544 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the T1 network or DSX-1 interface, or internally from the ASE. as part of the Visual UpTime Select system, Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 90%, noncondensing Input 100 to 120 VAC lyzed from the Visual UpTime Select Web client. Frequency 50/60 Hz As a service level management tool, ASEs Input Current Rating 0.5 amps indicate when services are being met, provide Line Rate 1.544 Mbps ±50 bps synchronous warnings when services start to degrade, and Line Format AMI or B9ZS line coding Framing ESF or D4 framing formats ESF FDL ANSI T1.403, AT&T TR54016, Both, or None Hardware Warranties Input Signal 0dB to -36dB Enhanced Gold, Bronze, and International Output Signal 0, -7.5dB, -15dB, -22.5dB LBO Gold ASE hardware warranty service programs Pulse Density AT&T 62411 are available to help you maximize your Connector 8-pin modular jack—USOC: RJ48C Timing Loop, DSX-1, or Internal Channel Selection 1 to 24 channels in any combination Configuration DCE for interfacing with DTE Data and Clock Leads ITU-T V.35 Ordering Information Signaling Leads EIA RS-232 (ITU-T V.28) For more details, please contact your Visual Data Rates 56 kbps x N or 64 kbps x N (N = 1 through 24) UpTime Select authorized reseller or HDLC Inversion Selectable V.35 data inversion Transmit Timing Basis Network selected-source timing Receive Timing Basis SCT, inverted SCT, SCTE Receive Line Data Not Valid RLSD, CTS o o o o o o o o collection and network performance monitor- which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and ana- Connector Female 34-pin V.35 connector Serial Port Interface Specifications 19200 or 9600 bps baud rate, 8 data bits no parity, 1 stop bit, EIA RS-232 DTE electrical format, RJ-45 connector Ethernet 10/100BaseT Interface Bite Rate 10 or 100 Mbps Connector 8-pin modular jack: RJ-48 send alerts when services are not met. investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643388 D-ENG-N Rev A Visual UpTime Select ASE model 807-0111 T1 CSU/DSU ASE With Modem The Visual UpTime® Select™ T1 CSU/DSU ASE is This ASE features an internal modem that allows Key features deployed on a T1 access line at the demarcation point users to establish a telephone connection to either • Inband management capabilities between the provider network and customer premises. the ASE’s administrative interface or a pass-through • Multi-Protocol or IP Transport software It supports full and fractional (FT1) T1 networks and connection through the serial port. • Service Level Agreement (SLA) metrics provides connectivity through V.35 interface. • Drop-and-Insert capabilities through DSX port • Internal modem In addition to performing standard CSU/DSU The ASE supports Multi-Protocol software for deploy- functions—such as BER tests, loopbacks, and power ment in standard frame relay or HDLC networks and failure detection—the ASE is capable of inserting IP Transport software for deployment in networks that management traffic. use IP switching. • Voice over IP (VoIP) analysis capability • Application analysis capability • LMI spoofing • LAN management port • Power loss detection • Realtime events T1 CSU/DSU model 807-0111 front view T1 CSU/DSU model 807-0111 rear view Wide Area Network T1 Access Line CSU/DSU ASE V.35 Line Modem Connection Optional LAN Connection PBX PBX T l h T1 CSU/DSU model 807-0111 position on network Technical Data Visual UpTime Select Server What are ASEs? T1 CSU/DSU ASE specifcations General Environment Power Requirements T1 Network Interface Network DTE Interface (Data Port) Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) Plastic case with internal power supply. ASEs (Analysis Service Elements) are data Weight 2.10 lbs. ing hardware devices placed on a wide area Data Rate 1.544 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the T1 network or DSX-1 interface, or internally from the ASE. as part of the Visual UpTime Select system, Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 90%, noncondensing Input 100 to 120 VAC lyzed from the Visual UpTime Select Web client. Frequency 50/60 Hz As a service level management tool, ASEs Input Current Rating 0.5 amps indicate when services are being met, provide Line Rate 1.544 Mbps ±50 bps synchronous warnings when services start to degrade, and Line Format AMI or B9ZS line coding Framing ESF or D4 framing formats ESF FDL ANSI T1.403, AT&T TR54016, Both, or None Hardware Warranties Input Signal 0dB to -36dB Enhanced Gold, Bronze, and International Output Signal 0, -7.5dB, -15dB, -22.5dB LBO Gold ASE hardware warranty service programs Pulse Density AT&T 62411 are available to help you maximize your Connector 8-pin modular jack—USOC: RJ48C Timing Loop, DSX-1, or Internal Channel Selection 1 to 24 channels in any combination Configuration DCE for interfacing with DTE Data and Clock Leads ITU-T V.35 Ordering Information Signaling Leads EIA RS-232 (ITU-T V.28) For more details, please contact your Visual Data Rates 56 kbps x N or 64 kbps x N (N = 1 through 24) UpTime Select authorized reseller or HDLC Inversion Selectable V.35 data inversion Transmit Timing Basis Network selected-source timing Receive Timing Basis SCT, inverted SCT, SCTE Receive Line Data Not Valid RLSD, CTS o o o o o o o o collection and network performance monitor- which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and ana- Connector Female 34-pin V.35 connector Serial Port Interface Specifications 19200 or 9600 bps baud rate, 8 data bits no parity, 1 stop bit, EIA RS-232 DTE electrical format, RJ-45 connector Ethernet 10/100BaseT Interface Bite Rate 10 or 100 Mbps Connector 8-pin modular jack: RJ-48 Modem Connector RJ11 Standard FCC Part 68 and IC-CS03 Compliance US and Canada send alerts when services are not met. investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643374 D-ENG-N Rev A Visual UpTime Select ASE model 807-0112 T1 CSU/DSU ASE With DSX-1, Drop-and-Insert, and Modem The Visual UpTime® Select™ T1 CSU/DSU ASE is The ASE’s “drop-and-insert” feature provides a Key features deployed on a T1 access line at the demarcation point secondary DSX-1 port that can connect to a Private • Inband management capabilities between the provider network and customer premises. Branch Exchange at a customer’s site. T1 Timeslots • Multi-Protocol or IP Transport software It supports full and fractional (FT1) T1 networks and can be segmented for a PBX on the same circuit • Service Level Agreement (SLA) metrics provides connectivity through V.35 and additional carrying data traffic (see figure). The ASE’s internal digital cross connect signal (DSX-1) interfaces. modem lets users establish a telephone connection • Drop-and-Insert capabilities through DSX port • Internal modem • Voice over IP (VoIP) analysis capability The ASE supports Multi-Protocol software for deploy- to either the ASE’s administrative interface or a pass- ment in standard frame relay or HDLC networks and IP through connection via the serial port. Transport software for deployment in networks that use IP switching. • Application analysis capability • LMI spoofing • LAN management port • Power loss detection • Realtime events T1 CSU/DSU model 807-0112 front view T1 CSU/DSU model 807-0112 rear view Wide Area Network T1 Access Line CSU/DSU ASE V.35 Line Modem Connection Optional LAN Connection PBX PBX T l h T1 CSU/DSU model 807-0112 position on network Technical Data Visual UpTime Select Server What are ASEs? T1 CSU/DSU ASE specifcations General Environment Power Requirements T1 Network Interface Network DTE Interface (Data Port) DSX-1 Interface Serial Port Interface Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) Plastic case with internal power supply. ASEs (Analysis Service Elements) are data Weight 2.10 lbs. ing hardware devices placed on a wide area Data Rate 1.544 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the T1 network or DSX-1 interface, or internally from the ASE. as part of the Visual UpTime Select system, Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating/Storage Humidity 10% to 90%, noncondensing data gathered by ASEs is stored in the Visual Input 100 to 120 VAC UpTime Select server and displayed and ana- Frequency 50/60 Hz lyzed from the Visual UpTime Select Web client. Input Current Rating 0.5 amps As a service level management tool, ASEs Line Rate 1.544 Mbps ±50 bps synchronous indicate when services are being met, provide Line Format AMI or B9ZS line coding warnings when services start to degrade, and Framing ESF or D4 framing formats send alerts when services are not met. ESF FDL ANSI T1.403, AT&T TR54016, Both, or None Input Signal 0dB to -36dB Hardware Warranties Output Signal 0, -7.5dB, -15dB, -22.5dB LBO Enhanced Gold, Bronze, and International Pulse Density AT&T 62411 Gold ASE hardware warranty service programs Connector 8-pin modular jack—USOC: RJ48C are available to help you maximize your Timing Loop, DSX-1, or Internal investment in Visual UpTime Select. For more Channel Selection 1 to 24 channels in any combination detailed warranty information, visit: Configuration DCE for interfacing with DTE www.flukenetworks.com/visualcustomercare Data and Clock Leads ITU-T V.35 Signaling Leads EIA RS-232 (ITU-T V.28) Ordering Information Data Rates 56 kbps x N or 64 kbps x N (N = 1 through 24) For more details, please contact your Visual HDLC Inversion Selectable V.35 data inversion UpTime Select authorized reseller or Transmit Timing Basis Network selected-source timing Fluke Networks Sales at (800) 240-4010 Receive Timing Basis SCT, inverted SCT, SCTE or (301) 296-2300. Receive Line Data Not Valid RLSD, CTS Connector Female 34-pin V.35 connector Line Rate 1.544 Mbps ±50 bps o o o o o o o o Line Format AMI or B8ZS Framing ESF or D4 (SF) Input Signal -1dB to -11dB Line Equalization 0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft Connector RJ-45 Channel Selection 1 to 24 channels in any combination Specifications 19200 or 9600 bps baud rate, 8 data bits no parity, 1 stop bit, EIA RS-232 DTE electrical format, RJ-45 connector Ethernet 10/100BaseT Interface Bite Rate 10 or 100 Mbps Connector 8-pin modular jack: RJ-48 Modem Specifications RJ11 connector, FCC Part 68 and IC-CS03 standards, compliance in US and Canada collection and network performance monitor- which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, N E T W O R K S U P E R V I S I O N Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643363 D-ENG-N Rev A Visual UpTime Select ASE model 807-0100 Dual-port Dual-analysis ASE T1 CSU/DSU with DSX-1 and Drop-and-Insert capabilities The Visual UpTime® Select™ Dual-port Dual-analysis separate frame relay ports (for example, voice over Key features T1 CSU/DSU ASE is deployed on a T1 access line at the FR1, plus SNA over FR2). In addition, domestic and • Inband management capabilities demarcation point between the provider network and international frame relay services can exist on two • Multi-Protocol or IP Transport software customer premises. It supports frame relay/HDLC and separate ports on the same access line. • Service Level Agreement (SLA) metrics IP Transport capabilities. • Drop-and-Insert capabilities through DSX port • Voice over IP (VoIP) analysis capability • Application analysis capability In addition to performing standard CSU/DSU This unit combines two model 109 T1 CSU/DSU ASEs functions—such as BER tests, loopbacks, and power with a built-in connector cable and analyzes data on failure detection—the ASE is capable of inserting both ports. The unit’s second port can be used for management traffic. Up to 155 PVCs or IP circuits can a redundant router in the event of primary router be managed per ASE. failure. Multiple traffic types can be concentrated on • LMI spoofing • LAN management port • Second analysis port for redundant router, different traffic types • Power loss detection • Realtime events T1 CSU/DSU model 807-0109 front view (ASE model 100 is two model 109 units in a rack mount) ASE 1 ASE 2 DSX T1 ASE 2 PORT 2 ASE 1 PORT 1 T1-DSX Cable (801-0096) T1 CSU/DSU model 807-0100 rear view Wide Area Network Optional LAN Connection on data 1 CSU/DSU Dual-port ASE PBX DSX-1 V.35 Ports data 1 T1 CSU/DSU model 807-0100 on network Technical Data data 2 PBX What are ASEs? T1 CSU/DSU ASE specifcations General Environment Power Requirements T1 Network Interface Network DTE Interface (Data Port) DSX-1 Interface Serial Port Interface Ethernet 10/100BaseT Interface Dimensions 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) Plastic case with internal power supply. ASEs (Analysis Service Elements) are data Weight 2.10 lbs. ing hardware devices placed on a wide area Data Rate 1.544 Mbps synchronous network (WAN) or Local Area Network (LAN) Timing Mode Derived externally from the T1 network or DSX-1 interface, or internally from the ASE. as part of the Visual UpTime Select system, Operating Temperature 0 to +40 C (+32 to +104 F) Storage Temperature -20 to +55 C (-4 to +131 ×F) Clearance Requirement Minimum of 3” (7.62 cm) space on sides. Operating and Storage Humidity 10% to 90%, noncondensing Input 100 to 240 VAC lyzed from the Visual UpTime Select Web client. Frequency 50/60 Hz As a service level management tool, ASEs Input Current Rating 0.5 amps indicate when services are being met, provide Line Rate 1.544 Mbps ±50 bps synchronous warnings when services start to degrade, and Line Format AMI or B9ZS line coding Framing ESF or D4 framing formats ESF FDL ANSI T1.403, AT&T TR54016, Both, or None Hardware Warranties Input Signal 0dB to -36dB Enhanced Gold, Bronze, and International Output Signal 0, -7.5dB, -15dB, -22.5dB LBO Gold ASE hardware warranty service programs Pulse Density AT&T 62411 are available to help you maximize your Connector 8-pin modular jack—USOC: RJ48C Timing Loop, DSX-1, or Internal Channel Selection 1 to 24 channels in any combination Configuration DCE for interfacing with DTE Data and Clock Leads ITU-T V.35 Ordering Information Signaling Leads EIA RS-232 (ITU-T V.28) For more details, please contact your Visual Data Rates 56 kbps x N or 64 kbps x N (N = 1 through 24) UpTime Select authorized reseller or HDLC Inversion Selectable V.35 data inversion Transmit Timing Basis Network selected-source timing Receive Timing Basis SCT, inverted SCT, SCTE Receive Line Data Not Valid RLSD, CTS Connector Female 34-pin V.35 connector Line Rate 1.544 Mbps ±50 bps o o o o o o o o collection and network performance monitor- which offers in-depth, real-time, and historical visibility into the performance of your applications infrastructure. In the system, data gathered by ASEs is stored in the Visual UpTime Select server and displayed and ana- Line Format AMI or B8ZS Framing ESF or D4 (SF) Input Signal -1dB to -11dB Line Equalization 0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft send alerts when services are not met. investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare Fluke Networks Sales at (800) 240-4010 or (301) 296-2300. Connector RJ-45 Channel Selection 1 to 24 channels in any combination Specifications 19200 or 9600 bps baud rate, 8 data bits no parity, 1 stop bit, EIA RS-232 DTE electrical format, RJ-45 connector Fluke Networks P.O. Box 777, Everett, WA USA 98206-0777 Bite Rate 10 or 100 Mbps Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact. Connector 8-pin modular jack: RJ-48 N E T W O R K S U P E R V I S I O N ©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 264xxxx D-ENG-N Rev A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Modify Date : 2006:08:16 14:16:13-04:00 Create Date : 2006:08:16 14:08:41-04:00 Metadata Date : 2006:08:16 14:16:13-04:00 Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Title : Datasheet_4xT1_E1.indd Creator : jburbrid Document ID : uuid:55e2837c-a3bc-4b46-b099-984e16d30929 Instance ID : uuid:6ceece0b-4c4f-4c1f-bf9f-444d9e6a3efc Producer : Acrobat Distiller 7.0 (Windows) Page Count : 34 Author : jburbridEXIF Metadata provided by EXIF.tools