Visual UpTime Select
ASE model 807-0115

4xT1/E1 i nline probe ASE
With LinkSafe capabilities
The Visual UpTime® Select™ 4xT1/E1 inline probe

The 4xT1/E1 ASE includes LinkSafe™ technology

Key features

ASE enhances the data analysis functionality of the

to protect circuit integrity in case of a power outage

• Four management ports

Visual UpTime Select system for enterprises with

and it also delivers a notification alarm if there is a

• MLPPP support on IP Transport software

two-to-four T1 or E1 circuits terminating at a single

power failure.

• Inband management capability

location. The ASE provides up to 6.176 Mbps

• LinkSafe technology
• Power loss detection
• Service Level Agreement (SLA) metrics

Designed for locations with multiple circuits

(T-standard) or 8.192 Mbps (E-standard) of detailed

terminating at a single device, the 4xT1/E1 is typi-

network traffic analysis and management, while

cally deployed as an inline probe between the service

maintaining full wire speed pass-through of all

provider’s edge device and the customer’s termination

traffic. In its initial release, the ASE supports IP

equipment. The figure below highlights the multilink

• Application analysis capability

Transport software over MultiLink Point-to-Point

deployment for the 4xT1/E1 ASE.

• LMI spoofing

Protocol (MLPPP) T1 links.

• LAN management port
• Realtime events

4xT1/E1 inline probe model 807-0115 front

4xT1/E1 inline probe model model 807-0115 rear

Optional LAN Connection
Bundled
T1 Line

WAN
4xT1/E1 inline ASE

CPE Router

LAN
4xT1/E1 inline probe model 807-0115 position on network

Technical Data

What are ASEs?

4xT1/E1 inline probe ASE specifcations
General

Environment

Power Requirements

T1 Network Interface
(Ports 1-4)

E1 Network Interface
(Ports 1-4)

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)

ASEs (Analysis Service Elements) are data

Weight

7 lbs.

collection and network performance monitor-

Data Rate

T1: 1.536 Mbps, E1: 1.984 Mbps

ing hardware devices placed on a wide area

Timing Mode

Derived externally from the T1 or E1 network,
user interface, or internally from the ASE.

network (WAN) or Local Area Network (LAN)

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 80%, noncondensing

Input

100 to 240 VAC

UpTime Select server and displayed and ana-

Frequency

50/60 Hz

lyzed from the Visual UpTime Select Web client.

Input Current Rating

0.5 amps

As a service level management tool, ASEs

Line Rate

1.544 Mbps ±50 bps synchronous

indicate when services are being met, provide

Line Format

B8ZS line coding

warnings when services start to degrade, and

Framing

ESF framing formats

send alerts when services are not met.

Input Signal

0dB to -36dB

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Hardware Warranties

Pulse Density

AT&T 62411

Enhanced Gold, Bronze, and International

Connector

100 ohm 8-pin modular jack—USOC: RJ48C

Gold ASE hardware warranty service programs

Timing

Network or User

are available to help you maximize your

Channel Selection

1 to 24 channels in any combination

investment in Visual UpTime Select. For more

Line Rate

2.048 Mbps ±102.4 bps synchronous

detailed warranty information, visit:

Line Format

HDB3 line coding

www.flukenetworks.com/visualcustomercare

Framing

CRC4 or FAS framing formats

o

o

o

o

o

as part of the Visual UpTime Select system,

o

o

o

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual

Time Slot 16

CAS, CCS, or Data

Ordering Information

Input Signal

0dB to -43dB

For more details, please contact your Visual

Output Signal

0dB

UpTime Select authorized reseller or

Connector

120 ohm RJ-48C balanced and 75 ohm BNC unbalanced coaxial

Fluke Networks Sales at (800) 240-4010

Channel Selection

1-31 (includes channel 16) or 1-15, 17-31 (does
not include channel 16)

Baud Rate

19200 or 9600 bps

Parity

8 data bits, no parity

Stop Bit

1 stop bit

Electrical Format

EIA RS-232, DTE

Connector

RJ-45

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643418 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0113

T1/E1 i nline probe ASE
With LinkSafe capabilities
The Visual UpTime® Select™ T1/E1 LinkSafe™ inline

When configured for use on an E1 network, the ASE

Key features

probe ASE is deployed inline on a T1 or E1 access line,

complies with the physical/electrical characteristics

• Inband management capabilities

typically between a service provider’s edge device and

defined by ITU-T G.703 at 2.048 Megabits per second

• LinkSafe technology

CSU/DSU. This ASE supports Multi-Protocol software

(Mbps). The ASE also complies with the synchronous

• Power loss detection

for deployment in standard frame relay or HDLC

frame structure specifications defined by ITU-T G.704,

networks and IP Transport software for deployment

including the option to use channel 16 for data or

in frame relay or HDLC-based networks that use IP

signalling. You can either connect to the E1 network

switching. The ASE also includes LinkSafe technology

using a 120 ohm balanced cable or BNC coax 75 ohm

to protect circuit integrity in case of an ASE outage,

unbalanced cables.

• Multi-Protocol or IP Transport software
• Service Level Agreement (SLA) metrics
• Voice over IP (VoIP) analysis capability
• Application analysis capability

as well as power failure notification.

• LMI spoofing
• LAN management port
• Realtime events

T1/E1 inline probe model 807-0113 front view

T1/E1 inline probe model model 807-0113 rear view
Optional LAN Connection
T1/E1 Access Line

LAN
WAN
T1/E1 inline ASE

CSU/DSU

CPE Router

Visual UpTime
Select Server

T1/E1 inline probe model 807-0113 position on network

Technical Data

What are ASEs?

T1/E1 inline probe ASE specifcations
General

Environment

Power Requirements

T1 Network Interface

E1 Network Interface

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

collection and network performance monitor-

Data Rate

1.544 Mbps synchronous

ing hardware devices placed on a wide area

Timing Mode

Derived externally from the T1 or E1 network,
user interface, or internally from the ASE.

network (WAN) or Local Area Network (LAN)

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 80%, noncondensing

Input

100 to 240 VAC

UpTime Select server and displayed and ana-

Frequency

50/60 Hz

lyzed from the Visual UpTime Select Web client.

Input Current Rating

0.5 amps

As a service level management tool, ASEs

Line Rate

1.544 Mbps ±50 bps synchronous

indicate when services are being met, provide

Line Format

AMI or B9ZS line coding

warnings when services start to degrade, and

Framing

ESF or D4 framing formats

send alerts when services are not met.

Input Signal

0dB to -36dB

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Hardware Warranties

Pulse Density

AT&T 62411

Enhanced Gold, Bronze, and International

Connector

8-pin modular jack—USOC: RJ48C

Gold ASE hardware warranty service programs

Timing

Network, User, or Internal

are available to help you maximize your

Channel Selection

1 to 24 channels in any combination

investment in Visual UpTime Select. For more

Line Rate

2.048 Mbps ±102.4 bps synchronous

detailed warranty information, visit:

Line Format

HDB3 or AMI line coding

www.flukenetworks.com/visualcustomercare

Framing

CRC4 or FAS framing formats

o

o

o

o

o

as part of the Visual UpTime Select system,

o

o

o

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual

Time Slot 16

CAS, CCS, or Data

Ordering Information

Input Signal

0dB to -43dB

For more details, please contact your Visual

Output Signal

0dB to LBO

UpTime Select authorized reseller or

Connector

RJ-45 (100 ohm balanced)
or BNC (75 ohm unbalanced)

Fluke Networks Sales at (800) 240-4010

Channel Selection

1-31 (includes channel 16
or 1-15, 17-31 (does not include channel 16)

Baud Rate

19200 or 9600 bps

Parity

8 data bits, no parity

Stop Bit

1 stop bit

Electrical Format

EIA RS-232, DTE

Connector

RJ-45

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643532 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0120

10/100 Ethernet i nline ASE LE
With LinkSafe capabilities
The Visual UpTime® Select™ 10/100 Ethernet

line between LAN devices, such as the LAN switch

Key features

inline ASE LE enhances the analysis functionality

and router (see figure). Other options include posi-

• Inline or SPAN mode deployment

of the Visual UpTime Select system for Ethernet

tioning the ASE on the Ethernet segment between a

• LinkSafe technology

networks. The ASE provides up to 6 Mbps of detailed

subscriber’s router and a Network Terminating Unit

• IP Transport or LAN Visibility software

network traffic analysis and management, while

(NTU) such as a DSL modem or a Service Provider

maintaining full wire speed pass-through of all traf-

switch (Ethernet as WAN access), or connecting the

fic. It supports both IP Transport and LAN Visibility

ASE to a router or switch SPAN port.

• Voice over IP (VoIP) analysis capability
• Application analysis capability
• LAN management port

software When deployed inline, the ASE includes

The LAN Visibility Ethernet ASE is deployed on

LinkSafe™ technology to protect circuit integrity if

the LAN. The inline LAN Visibility ASE collects and

• Power loss detection

in case of an ASE outage, as well as power failure

displays application flow traffic on the LAN between

• Realtime events

notification.

clients and application server. In contrast, the IP

Designed for business class DSL and cable, the

Transport ASE is designed to display only traffic to or

10/100 Ethernet inline ASE LE has a wide variety of

from the WAN, and ignore local traffic (such as be-

deployment options. The IP Transport Ethernet ASE is

tween a client and an Internet or application server).

typically deployed as an inline probe on the access

Ethernet inline probe model 807-0120 front view

Client

Access
Line(s)
Wide Area
Network
NTU
Customer
IP Transport LAN Switch
device Edge Router Ethernet ASE

Server

LAN
LAN Visibility
Ethernet ASE
Ethernet inline probe model 807-0120 deployed inline IP Transport and on LAN in LAN Visibility mode

Technical Data

What are ASEs?

Ethernt inline probe ASE specifcations
General

Environment

Dimensions

7.5” (19.1 cm) x 6” (15.2 cm) x 1.5” (3.8 cm)

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

collection and network performance monitor-

Maximum Data Rate

6 Mbps

Operating Temperature

o

ing hardware devices placed on a wide area
o

o

o

0 to +40 C (+32 to +104 F)
o

o

o

o

network (WAN) or Local Area Network (LAN)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

as part of the Visual UpTime Select system,

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

which offers in-depth, real-time, and historical

Input

100 to 240 VAC

visibility into the performance of your

Frequency

50/60 Hz

applications infrastructure. In the system,

Input Current Rating

0.5 amps

data gathered by ASEs is stored in the Visual

LAN and WAN
Ethernet Interface

Bit Rate

10/100 Mbps

Connector

8-pin modular jack: RJ-45

Serial Port Interface

Baud Rate

19200 or 9600 bps

Parity

8 data bits, no parity

Stop Bit

1 stop bit

Electrical Format

EIA RS-232, DTE

Connector

RJ-45

Power Requirements

UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client.
As a service level management tool, ASEs
indicate when services are being met, provide
warnings when services start to degrade, and
send alerts when services are not met.

Hardware Warranties
Enhanced Gold, Bronze, and International
Gold ASE hardware warranty service programs
are available to help you maximize your
investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare
Ethernet inline probe model model 807-0120 rear view

Ordering Information
For more details, please contact your Visual
UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643441 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0122

10/100 Ethernet i nline ASE
With LinkSafe capabilities
The Visual UpTime® Select™ 10/100 Ethernet

line between LAN devices, such as the LAN switch

Key features

inline ASE enhances the analysis functionality of the

and router (see figure). Other options include posi-

• Inline or SPAN mode deployment

Visual UpTime Select system for Ethernet networks.

tioning the ASE on the Ethernet segment between a

• LinkSafe technology

The ASE provides up to 100 Mbps of detailed network

subscriber’s router and a Network Terminating Unit

• IP Transport or LAN Visibility software

traffic analysis and management, while maintaining

(NTU) such as a DSL modem or a Service Provider

full wire speed pass-through of all traffic. It supports

switch (Ethernet as WAN access), or connecting the

both IP Transport and LAN Visibility software When

ASE to a router or switch SPAN port.

• Voice over IP (VoIP) analysis capability
• Application analysis capability
• Power loss detection
• LAN management port
• Realtime events

deployed inline, the ASE includes LinkSafe™ technol-

The LAN Visibility Ethernet ASE is deployed on

ogy to protect circuit integrity if in case of an ASE

the LAN. The inline LAN Visibility ASE collects and

outage, as well as power failure notification.

displays application flow traffic on the LAN between

Designed for business class DSL and cable, the

clients and application server. In contrast, the IP

10/100 Ethernet inline ASE has a wide variety of

Transport ASE is designed to display only traffic to or

deployment options. The IP Transport Ethernet ASE is

from the WAN, and ignore local traffic (such as be-

typically deployed as an inline probe on the access

tween a client and an Internet or application server).

Ethernet inline probe model 807-0122 front view

Client

Access
Line(s)
Wide Area
Network
NTU
Customer
IP Transport LAN Switch
device Edge Router Ethernet ASE

Server

LAN
LAN Visibility
Ethernet ASE

Ethernet inline probe model 807-0122 deployed inline IP Transport and on LAN in LAN Visibility mode

Technical Data

What are ASEs?

Ethernt inline probe ASE specifcations
General

Environment

Dimensions

7.5” (19.1 cm) x 6” (15.2 cm) x 1.5” (3.8 cm)

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

collection and network performance monitor-

Maximum Data Rate

100 Mbps

Operating Temperature

o

ing hardware devices placed on a wide area

o

o

o

0 to +40 C (+32 to +104 F)
o

o

o

o

network (WAN) or Local Area Network (LAN)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

as part of the Visual UpTime Select system,

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

which offers in-depth, real-time, and historical

Input

100 to 240 VAC

visibility into the performance of your

Frequency

50/60 Hz

applications infrastructure. In the system,

Input Current Rating

0.5 amps

data gathered by ASEs is stored in the Visual

LAN and WAN
Ethernet Interface

Bit Rate

10/100 Mbps

Connector

8-pin modular jack: RJ-45

Serial Port Interface

Baud Rate

19200 or 9600 bps

Parity

8 data bits, no parity

Stop Bit

1 stop bit

Electrical Format

EIA RS-232, DTE

Connector

RJ-45

Power Requirements

UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client.
As a service level management tool, ASEs
indicate when services are being met, provide
warnings when services start to degrade, and
send alerts when services are not met.

Hardware Warranties
Enhanced Gold, Bronze, and International
Gold ASE hardware warranty service programs
are available to help you maximize your
investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare
Ethernet inline probe model model 807-0122 rear view

Ordering Information
For more details, please contact your Visual
UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643434 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0220

10/100/1000 Ethernet ASE
With SPAN mode capabilities
The Visual UpTime® Select™ 10/100/1000 Ethernet

The LAN Visibility Ethernet ASE is deployed on the

Key features

ASE enhances the analysis functionality of Visual

LAN. The ASE collects and displays application flow

• 500 MB of total analysis

UpTime Select for Ethernet networks. The ASE

traffic on the LAN between clients and application

• SPAN mode deployment

provides up to 500 Mbps of detailed network traffic

server. In contrast, the IP Transport ASE is designed

• Deployable in DS3, NxDS3, Fractional

analysis and management, while maintaining full wire

to display only traffic to or from the WAN, and ignore

speed pass-through of all traffic. It supports both IP

local traffic (such as between a client and an Inter-

Transport and LAN Visibility software

net or application server).

OC3, and Ethernet to Premises topologies
• IP Transport or LAN Visibility software
• Voice over IP (VoIP) analysis capability

Designed for business class DSL and cable, the
10/100/1000 Ethernet ASE has a wide variety of

• Application analysis capability

deployment options. The IP Transport Ethernet ASE is

• LAN management port

deployed off a LAN switch SPAN port (see figure).

• Realtime events

Ethernet inline probe model 807-0220 front view

Ethernet inline probe model model 807-0220 rear view

Customer
Edge Router

LAN Switch

Wide Area
Network

SPAN port
Ethernet ASE
Ethernet probe model 807-0220 deployed on a LAN switch SPAN port

Technical Data

LAN

What are ASEs?

Ethernt inline probe ASE specifcations
General

Environment

Dimensions

17.3” (43.9 cm) x 12” (30.5 cm) x 3.5” (8.9 cm)

ASEs (Analysis Service Elements) are data

Weight

10.45 lbs.

collection and network performance monitor-

Maximum Data Rate

500 Mbps

Operating Temperature

o

ing hardware devices placed on a wide area

o

o

o

0 to +40 C (+32 to +104 F)
o

o

o

o

network (WAN) or Local Area Network (LAN)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

as part of the Visual UpTime Select system,

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

which offers in-depth, real-time, and historical

Input

100 to 240 VAC

visibility into the performance of your

Frequency

50/60 Hz

applications infrastructure. In the system,

Input Current Rating

0.5 amps

data gathered by ASEs is stored in the Visual

LAN and WAN
Ethernet Interface

Bit Rate

10/100/1000 Mbps

Connector

8-pin modular jack: RJ-45

Serial Port Interface

Baud Rate

19200 or 9600 bps

Parity

8 data bits, no parity

Stop Bit

1 stop bit

Electrical Format

EIA RS-232, DTE

Connector

9-pin D, male per EIA-574

Power Requirements

UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client.
As a service level management tool, ASEs
indicate when services are being met, provide
warnings when services start to degrade, and
send alerts when services are not met.

Hardware Warranties
Enhanced Gold, Bronze, and International
Gold ASE hardware warranty service programs
are available to help you maximize your
investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Ordering Information
For more details, please contact your Visual
UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643429 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0106

HSSI i nline probe ASE
With LinkSafe capabilities
The Visual UpTime® Select™ HSSI LinkSafe™ inline

The ASE also includes LinkSafe technology to protect

Key features

probe ASE is deployed inline on a High Speed Serial

circuit integrity in case of an ASE outage, as well as

• Inband management capabilities

Interface (HSSI) access line, typically between a

power failure notification.

• LinkSafe technology

CSU/DSU and customer edge router. It is capable of

• Power loss detection

monitoring traffic flowing through a bi-directional

minal Equipment (DTE) for monitoring traffic to the

HSSI connection at data rates up to 44.7 Mbps.

network and Data Communication Equipment (DCE)

• Multi-Protocol or IP Transport software
• Service Level Agreement (SLA) metrics
• Application analysis capability
• LMI spoofing

The HSSI ASE has two HSSI interfaces, Data Ter-

The HSSI ASE supports Multi-Protocol software for

for monitoring traffic from the network. Because of

deployment in standard frame relay or HDLC networks

its high speed capabilities, a HSSI ASE can support

and IP Transport software for deployment in frame

data passed through the CSU/DSU from NxT1

relay or HDLC-based networks that use IP switching.

and DS3 lines.

• LAN management port
• Realtime events

HSSI inline probe model 807-0106 front view

HSSI inline probe model model 807-0106 rear view

Optional LAN
Connection
Access Line

LAN

WAN
CSU/DSU

Inline ASE

CPE Router

Visual UpTime
Select Server
HSSI inline probe model 807-0106 position on network

Technical Data

What are ASEs?

HSSI inline probe ASE specifcations
Dimensions

17.3” (43.9 cm) x 12” (30.5 cm) x 3.5” (8.9 cm)

ASEs (Analysis Service Elements) are data

Weight

10.45 lbs.

collection and network performance monitor-

Data Rate

0 to 44.736 Mbps synchronous

ing hardware devices placed on a wide area

Timing Mode

RD: Always synchronous with SCR
SD: Synchronous with SCT or SCTE

network (WAN) or Local Area Network (LAN)

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 80%, noncondensing

Input

100 to 240 VAC

UpTime Select server and displayed and ana-

Frequency

50/60 Hz

lyzed from the Visual UpTime Select Web client.

Input Current Rating

1 amp

As a service level management tool, ASEs

HSSI Interface

Configuration

Two HSSI interfaces: one DTE and one DCE for
monitoring to-network and from-network traffic.

indicate when services are being met, provide

Serial Port Interface

Baud Rate

19200 or 9600 bps

Parity

8 data bits, no parity

Stop Bit

1 stop bit

Hardware Warranties

Electrical Format

EIA RS-232, DTE

Enhanced Gold, Bronze, and International

Connector

9-pin D, male per EIA-574

Gold ASE hardware warranty service programs

Bite Rate

10 or 100 Mbps

are available to help you maximize your

Connector

8-pin modular jack: RJ-48

investment in Visual UpTime Select. For more

General

Environment

Power Requirements

Ethernet 10/100BaseT
Interface

o

o

o

o

o

as part of the Visual UpTime Select system,

o

o

o

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual

warnings when services start to degrade, and
send alerts when services are not met.

detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Ordering Information
For more details, please contact your Visual
UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643476 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0104

V.35 i nline probe ASE
With LinkSafe capabilities
The Visual UpTime® Select™ V.35 LinkSafe™ inline

The V.35 inline probe ASE supports V.35 connectiv-

Key features

probe ASE is deployed inline on a T1 access line,

ity through a V.35 Data Terminal Equipment (DTE)

• Inband management capabilities

typically between a CSU/DSU and customer premises

interface on the network side and Data Communica-

• LinkSafe technology

equipment. This ASE supports Multi-Protocol software

tions Equipment (DCE) interface on the user side.

• Multi-Protocol or IP Transport software

for deployment in standard frame relay or HDLC

• Service Level Agreement (SLA) metrics
• Voice over IP (VoIP) analysis capability

The ASE operates at data rates up to 2.048 Mbps,

networks and IP Transport software for deployment

deriving timing from the network-side and sourcing

in frame relay or HDLC-based networks that use IP

timing on the user side. It also includes LinkSafe

switching.

technology to protect circuit integrity in case of an

• Application analysis capability

ASE outage, as well as power failure notification.

• LMI spoofing
• LAN management port
• Power loss detection
• Realtime events

V.35 inline probe model 807-0104 front view

V.35 inline probe model model 807-0104 rear view

Optional LAN
Connection
Access Line

LAN

WAN
CSU/DSU

Inline ASE

CPE Router

Visual UpTime
Select Server
V.35 inline probe model 807-0104 position on network

Technical Data

What are ASEs?

V.35 inline probe ASE specifcations
General

Environment

Power Requirements

V.35 User Interface
(DCE)

V.35 Network
Interface
(DTE)

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

ing hardware devices placed on a wide area

Data Rate

0 to 2.048 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

RD: Always synchronous with SCR
SD: Synchronous with SCT or SCTE

as part of the Visual UpTime Select system,

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 80%, noncondensing

Input

100 to 240 VAC

lyzed from the Visual UpTime Select Web client.

Frequency

50/60 Hz

As a service level management tool, ASEs

Input Current Rating

0.5 amps

indicate when services are being met, provide

Configuration

DCE for interfacing with DTE

warnings when services start to degrade, and

Data and Clock Leads

ITU-T V.35

Signaling Leads

EIA RS-232 (ITU-T V.28)

Connector

Female 34-pin V.35 connector

Hardware Warranties

Signaling

RTS, DTR

Enhanced Gold, Bronze, and International

Configuration

DTE for interfacing with DCE

Gold ASE hardware warranty service programs

Data and Clock Leads

ITU-T V.35

are available to help you maximize your

Signaling Leads

EIA RS-232 (ITU-T V.28)

Connector

Female 34-pin V.35 connector

Signaling

CTS, RLSD, DSR

Baud Rate

19200 or 9600 bps

Parity

8 data bits, no parity

Ordering Information

Stop Bit

1 stop bit

For more details, please contact your Visual

Electrical Format

EIA RS-232, DTE

Connector

RJ-45

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

o

o

o

o

o

o

o

o

collection and network performance monitor-

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and ana-

send alerts when services are not met.

investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643465 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0105

X.21 i nline probe ASE
With LinkSafe capabilities
The Visual UpTime® Select™ X.21 LinkSafe™ inline

The ASE supports X.21 connectivity through a X.21

Key features

probe ASE is deployed inline on an access line, typical-

Data Terminal Equipment (DTE) interface on the

• Inband management capabilities

ly between a CSU/DSU and customer premises equip-

network side and Data Communications Equipment

• LinkSafe technology

ment (CPE). It supports Multi-Protocol software for

(DCE) interface on the user side.

• Multi-Protocol or IP Transport software

deployment in standard frame relay or HDLC networks

• Service Level Agreement (SLA) metrics
• Voice over IP (VoIP) analysis capability

The ASE operates at data rates up to 2.048 Mbps,

and IP Transport software for deployment in frame

deriving timing from the network-side and sourcing

relay or HDLC-based networks that use IP switching.

timing on the user side. It also includes LinkSafe
technology to protect circuit integrity in case of an

• Application analysis capability

ASE outage, as well as power failure notification.

• LMI spoofing
• LAN management port
• Power loss detection
• Realtime events

X.21 inline probe model 807-0105 front view

X.21 inline probe model model 807-0105 rear view

Optional LAN
Connection
Access Line

LAN

WAN
CSU/DSU

Inline ASE

CPE Router

Visual UpTime
Select Server
X.21 inline probe model 807-0105 position on network

Technical Data

What are ASEs?

X.21 inline probe ASE specifcations
General

Environment

Power Requirements

X.21 User Interface
(DCE)

X.21 Network
Interface (DTE)

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

ing hardware devices placed on a wide area

Data Rate

0 to 2.048 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

RD: Always synchronous with SCR
SD: Synchronous with SCT or SCTE

as part of the Visual UpTime Select system,

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 80%, noncondensing

Input

100 to 240 VAC

lyzed from the Visual UpTime Select Web client.

Frequency

50/60 Hz

As a service level management tool, ASEs

Input Current Rating

0.5 amps

indicate when services are being met, provide

Configuration

DCE for interfacing with DTE

warnings when services start to degrade, and

Data and Clock Leads

ITU-CCITT X.21

Signaling Leads

ITU-CCITT X.21

Connector

Female 15-pin X.21 connector

Hardware Warranties

Signaling

Indicate: Clear to Send control signal to the user
interface. Received and terminated by the ASE.

Enhanced Gold, Bronze, and International

Configuration

DTE for interfacing with DCE

Data and Clock Leads

ITU-CCITT X.21

Signaling Leads

ITU-CCITT X.21

Connector

Female 15-pin X.21 connector

Signaling

Control: Request to Send control signal from the
user interface. On while power is applied by the
ASE.

o

o

o

o

o

o

o

o

collection and network performance monitor-

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and ana-

send alerts when services are not met.

Gold ASE hardware warranty service programs
are available to help you maximize your
investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Ordering Information

Baud Rate

19200 or 9600 bps

For more details, please contact your Visual

Parity

8 data bits, no parity

UpTime Select authorized reseller or

Stop Bit

1 stop bit

Fluke Networks Sales at (800) 240-4010

Electrical Format

EIA RS-232, DTE

or (301) 296-2300.

Connector

RJ-45

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643152 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0200

DS3 i nline probe ASE
With LinkSafe capabilities
The Visual UpTime® Select™ DS3 LinkSafe™ inline

The DS3 inline probe ASE is designed for deploy-

Key features

probe ASE complies with Class A standards for

ment at the network demarcation point between a

• Inband management capabilities

countries using DS3 ATM lines (U.S. and Canada) and

subscriber’s CPE and the WAN. It can be deployed in

• LinkSafe technology

supports digital transmission at the DS3 rate of 44

ATM and mixed frame relay-ATM environments. The

• Multi-Protocol or IP Transport software

Mbps. This ASE supports Multi-Protocol software for

figure below shows the ASE positioned at the edge of

deployment in standard ATM networks and IP Trans-

an inter-worked frame relay-to-ATM network, allowing

port software for deployment in ATM-based networks

for SLA messaging between a frame relay DLCI and an

that use IP switching. The ASE also includes LinkSafe

ATM VPI/VCI.

• Service Level Agreement (SLA) metrics
• Application analysis capability
• LAN management port
• Realtime events

technology to protect circuit integrity in case of an
ASE outage, as well as power failure notification.

DS3 inline probe model 200 front view

DS3 inline probe model 200 rear view

LAN

Branch ASEs
Frame to ATM
Interworking
T1
Frame
Network

ATM ASE
ATM
Network

DS3 inline probe model 200 on ATM/Frame network

Technical Data

CPE
Router

Visual
UpTime
Select
server

What are ASEs?

DS3 inline probe ASE specifcations
General

Environment

Power Requirements

Network Interface

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

1 EIA unit (1.75”) high x 19” wide rack-mountable
chassis

ASEs (Analysis Service Elements) are data

Weight

10 lbs.

ing hardware devices placed on a wide area

Data Rate

to 45 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the network.

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating/Storage Humidity

10% to 90% non-condensing

Input

100 to 240 VAC

Frequency

50/60 Hz

Input Current Rating

0.5 amps

Line Rate

44.736 Mbps

As a service level management tool, ASEs

Cell Delineation

HEC or PLCP

indicate when services are being met, provide

Cell Scrambler

Enable or Disable

warnings when services start to degrade, and

Line Build Out

Long = more than 225 feet. Short = 225 feet or less.

send alerts when services are not met.

Connector

4 BNC (75 ohm), Network Tx and Rx, CPE Tx and Rx

Baud Rate

57600, 19200, or 9600 bps

Parity

8 data bits, no parity

Enhanced Gold, Bronze, and International

Stop Bit

1 stop bit

Gold ASE hardware warranty service programs

Electrical Format

EIA RS-232, DTE

are available to help you maximize your

Connector

9-pin D, male per EIA-574

investment in Visual UpTime Select. For more

Bite Rate

10 or 100 Mbps

detailed warranty information, visit:

Connector

8-pin modular jack: RJ-48

www.flukenetworks.com/visualcustomercare

o

o

o

o

o

collection and network performance monitor-

as part of the Visual UpTime Select system,

o

o

o

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client.

Hardware Warranties

Ordering Information
For more details, please contact your Visual
UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643490 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0201

E3 i nline probe ASE
With LinkSafe capabilities
The Visual UpTime® Select™ E3 LinkSafe™ inline

The E3 inline probe ASE is designed for deploy-

Key features

probe ASE complies with Class A standards for

ment at the network demarcation point between a

• Inband management capabilities

countries using E3 ATM lines and supports digital

subscriber’s CPE and the WAN. It can be deployed in

• LinkSafe technology

transmission at the E3 rate of 34 Mbps. This ASE

ATM and mixed frame relay-ATM environments. The

• Multi-Protocol or IP Transport software

supports Multi-Protocol software for deployment in

figure below shows the ASE positioned at the edge of

standard ATM networks and IP Transport software

an inter-worked frame relay-to-ATM network, allowing

for deployment in ATM-based networks that use IP

for SLA messaging between a frame relay DLCI and an

switching. The ASE also includes LinkSafe technology

ATM VPI/VCI.

• Service Level Agreement (SLA) metrics
• Application analysis capability
• LAN management port
• Realtime events

to protect circuit integrity in case of an ASE outage,
as well as power failure notification.

E3 inline probe model 201 front view

E3 inline probe model 201 rear view

LAN

Branch ASEs
Frame to ATM
Interworking
T1
Frame
Network

ATM ASE
ATM
Network

E3 inline probe model 201 on ATM/Frame network

Technical Data

CPE
Router

Visual
UpTime
Select
server

What are ASEs?

E3 inline probe ASE specifcations
General

Environment

Power Requirements

Network Interface

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

1 EIA unit (1.75”) high x 19” wide rack-mountable
chassis

ASEs (Analysis Service Elements) are data

Weight

10 lbs.

ing hardware devices placed on a wide area

Data Rate

to 34 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the network.

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating/Storage Humidity

10% to 90% non-condensing

Input

100 to 240 VAC

Frequency

50/60 Hz

Input Current Rating

0.5 amps

Line Rate

34.368 Mbps

As a service level management tool, ASEs

Cell Delineation

HEC or PLCP

indicate when services are being met, provide

Cell Scrambler

Enable or Disable

warnings when services start to degrade, and

Connector

4 BNC (75 ohm), Network Tx and Rx, CPE Tx and Rx

send alerts when services are not met.

Baud Rate

57600, 19200, or 9600 bps

Parity

8 data bits, no parity

Stop Bit

1 stop bit

Enhanced Gold, Bronze, and International

Electrical Format

EIA RS-232, DTE

Gold ASE hardware warranty service programs

Connector

9-pin D, male per EIA-574

are available to help you maximize your

Bite Rate

10 or 100 Mbps

investment in Visual UpTime Select. For more

Connector

8-pin modular jack: RJ-48

o

o

o

o

o

collection and network performance monitor-

as part of the Visual UpTime Select system,

o

o

o

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client.

Hardware Warranties

detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Ordering Information
For more details, please contact your Visual
UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643483 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0202

OC-3c/STM-1 i nline probe ASE
Single mode with LinkSafe capabilities
The Visual UpTime® Select™ OC-3c/STM-1 LinkSafe™

The OC-3c/STM-1 inline probe ASE is designed

Key features

inline probe ASE supports single mode ATM OC-3c

for deployment at the network demarcation point

• Inband management capabilities

physical lines, with SONET and SDH standards, at

between a subscriber’s CPE and the WAN. It can be

• LinkSafe technology

speeds up to 155 Mbps. This ASE supports Multi-Proto-

deployed in ATM and mixed frame relay-ATM environ-

• Multi-Protocol or IP Transport software

col software for deployment in standard ATM networks

ments. The figure below shows the ASE positioned

and IP Transport software for deployment in ATM-based

at the edge of an inter-worked frame relay-to-ATM

networks that use IP switching. The ASE also includes

network, allowing for SLA messaging between a frame

LinkSafe technology to protect circuit integrity in case

relay DLCI and an ATM VPI/VCI.

• Service Level Agreement (SLA) metrics
• Application analysis capability
• LAN management port

of an ASE outage, as well as power failure notification.

• Realtime events

OC-3c inline probe model 202 front view

OC-3c inline probe model 202 rear view

LAN

Branch ASEs
Frame to ATM
Interworking
OC-3c
ATM ASE

T1
Frame
Network

ATM
Network

OC-3c inline probe model 202 on ATM/Frame network

Technical Data

CPE
Router

Visual
UpTime
Select
server

What are ASEs?

OC-3c inline probe ASE specifcations
General

Environment

Power Requirements

Network Interface

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

1 EIA unit (1.75”) high x 19” wide rack-mountable
chassis

ASEs (Analysis Service Elements) are data

Weight

10 lbs.

ing hardware devices placed on a wide area

Data Rate

to 155 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the network.

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating/Storage Humidity

10% to 90% non-condensing

Input

100 to 240 VAC

Frequency

50/60 Hz

Input Current Rating

0.5 amps

Bypass

5 volt 1 amp DC

As a service level management tool, ASEs

Line Rate

155.52 Mbps

indicate when services are being met, provide

Line Mode

SONET or SDH

warnings when services start to degrade, and

Cell Delineation

HEC

send alerts when services are not met.

Cell Scrambler

Enable or Disable

Connectors

2 Sff Duplex-LC, Network Tx and Rx, CPE Tx and Rx

Wavelength

1274 nm/1356 nm

Enhanced Gold, Bronze, and International

Tx Average Output Power

-11dBm (typical) Measured with single mode cable

Gold ASE hardware warranty service programs

Rx Sensitivity

-33dBm (typical)

are available to help you maximize your

Baud Rate

57600, 19200, or 9600 bps

investment in Visual UpTime Select. For more

Parity

8 data bits, no parity

detailed warranty information, visit:

Stop Bit

1 stop bit

www.flukenetworks.com/visualcustomercare

Electrical Format

EIA RS-232, DTE

Connector

9-pin D, male per EIA-574

Ordering Information

Bite Rate

10 or 100 Mbps

For more details, please contact your Visual

Connector

8-pin modular jack: RJ-48

o

o

o

o

o

collection and network performance monitor-

as part of the Visual UpTime Select system,

o

o

o

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client.

Hardware Warranties

UpTime Select authorized reseller or
Fluke Networks Sales at (800) 240-4010

Compliant with Bellcore GR-253 CORE and ITE G.957 standards

or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643526 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0203

OC-3c/STM-1 i nline probe ASE
Multimode with LinkSafe capabilities
The Visual UpTime® Select™ OC-3c/STM-1 LinkSafe™

The OC-3c/STM-1 inline probe ASE is designed

Key features

inline probe ASE supports multimode ATM OC-3c

for deployment at the network demarcation point

• Inband management capabilities

physical lines, with SONET and SDH standards, at

between a subscriber’s CPE and the WAN. It can be

• LinkSafe technology

speeds up to 155 Mbps. This ASE supports Multi-

deployed in ATM and mixed frame relay-ATM environ-

• Multi-Protocol or IP Transport software

Protocol software for deployment in standard ATM

ments. The figure below shows the ASE positioned

networks and IP Transport software for deployment in

at the edge of an inter-worked frame relay-to-ATM

ATM-based networks that use IP switching. The ASE

network, allowing for SLA messaging between a frame

also includes LinkSafe technology to protect circuit

relay DLCI and an ATM VPI/VCI.

• Service Level Agreement (SLA) metrics
• Application analysis capability
• LAN management port
• Realtime events

integrity in case of an ASE outage, as well as power
failure notification.

OC-3c inline probe model 203 front view

OC-3c inline probe model 203 rear view

LAN

Branch ASEs
Frame to ATM
Interworking
OC-3c
ATM ASE

T1
Frame
Network

ATM
Network

OC-3c inline probe model 203 on ATM/Frame network

Technical Data

CPE
Router

Visual
UpTime
Select
server

What are ASEs?

OC-3c inline probe ASE specifcations
General

Environment

Power Requirements

Network Interface

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

1 EIA unit (1.75”) high x 19” wide rack-mountable
chassis

ASEs (Analysis Service Elements) are data

Weight

10 lbs.

ing hardware devices placed on a wide area

Data Rate

to 155 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the network.

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating/Storage Humidity

10% to 90% non-condensing

Input

100 to 240 VAC

Frequency

50/60 Hz

Input Current Rating

0.5 amps

Bypass

5 volt 1 amp DC

As a service level management tool, ASEs

Line Rate

155.52 Mbps

indicate when services are being met, provide

Line Mode

SONET or SDH

warnings when services start to degrade, and

Cell Delineation

HEC

send alerts when services are not met.

Cell Scrambler

Enable or Disable

Connectors

2 Sff Duplex-LC, Network Tx and Rx, CPE Tx and Rx

Wavelength

1270 nm/1380 nm

Tx Average Output Power

-16dBm (typical) Measured with 62.5µ/120
Multimedia cable

Gold ASE hardware warranty service programs

Rx Sensitivity

-33dBm (typical)

investment in Visual UpTime Select. For more

Baud Rate

57600, 19200, or 9600 bps

detailed warranty information, visit:

Parity

8 data bits, no parity

www.flukenetworks.com/visualcustomercare

Stop Bit

1 stop bit

o

o

o

o

o

collection and network performance monitor-

as part of the Visual UpTime Select system,

o

o

o

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and analyzed from the Visual UpTime Select Web client.

Hardware Warranties
Enhanced Gold, Bronze, and International
are available to help you maximize your

Electrical Format

EIA RS-232, DTE

Ordering Information

Connector

9-pin D, male per EIA-574

For more details, please contact your Visual

Bite Rate

10 or 100 Mbps

UpTime Select authorized reseller or

Connector

8-pin modular jack: RJ-48

Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643515 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0109

T1 CSU/DSU ASE
With DSX-1, Drop-and-Insert capabilities
The Visual UpTime® Select™ T1 CSU/DSU ASE is

In addition to performing standard CSU/DSU

Key features

deployed on a T1 access line at the demarcation point

functions—such as BER tests, loopbacks, and power

• Inband management capabilities

between the provider network and customer premises.

failure detection—the ASE is capable of inserting

• Multi-Protocol or IP Transport software

It supports full and fractional (FT1) T1 networks and

management traffic.

• Service Level Agreement (SLA) metrics

provides connectivity through V.35 and additional

• Drop-and-Insert capabilities through
DSX port
• Voice over IP (VoIP) analysis capability
• Application analysis capability

digital cross connect signal (DSX-1) interfaces.
The ASE supports Multi-Protocol software for deploy-

The ASE’s “drop-and-insert” feature provides a
secondary DSX-1 port that can connect to a Private
Branch Exchange at a customer’s site. T1 Timeslots

ment in standard frame relay or HDLC networks and

can be segmented for a PBX on the same circuit car-

IP Transport software for deployment in frame relay or

rying data traffic (see figure).

HDLC-based networks that use IP switching.

• LMI spoofing
• LAN management port
• Power loss detection
• Realtime events

T1 CSU/DSU model 807-0109 front view

T1 CSU/DSU model 807-0109 rear view

Wide Area
Network

T1 Access
Line

CSU/DSU
ASE

Optional LAN
Connection

PBX
PBX
Telephone
Telephone

T1 CSU/DSU model 807-0109 position on network

Technical Data

V.35
Line

Visual
UpTime
Select
Server

What are ASEs?

T1 CSU/DSU ASE specifcations
General

Environment

Power Requirements

T1 Network Interface

Network DTE Interface
(Data Port)

DSX-1 Interface

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply.

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

ing hardware devices placed on a wide area

Data Rate

1.544 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the T1 network or DSX-1
interface, or internally from the ASE.

as part of the Visual UpTime Select system,

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 90%, noncondensing

Input

100 to 120 VAC

lyzed from the Visual UpTime Select Web client.

Frequency

50/60 Hz

As a service level management tool, ASEs

Input Current Rating

0.5 amps

indicate when services are being met, provide

Line Rate

1.544 Mbps ±50 bps synchronous

warnings when services start to degrade, and

Line Format

AMI or B9ZS line coding

Framing

ESF or D4 framing formats

ESF FDL

ANSI T1.403, AT&T TR54016, Both, or None

Hardware Warranties

Input Signal

0dB to -36dB

Enhanced Gold, Bronze, and International

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Gold ASE hardware warranty service programs

Pulse Density

AT&T 62411

are available to help you maximize your

Connector

8-pin modular jack—USOC: RJ48C

Timing

Loop, DSX-1, or Internal

Channel Selection

1 to 24 channels in any combination

Configuration

DCE for interfacing with DTE

Data and Clock Leads

ITU-T V.35

Ordering Information

Signaling Leads

EIA RS-232 (ITU-T V.28)

For more details, please contact your Visual

Data Rates

56 kbps x N or 64 kbps x N (N = 1 through 24)

UpTime Select authorized reseller or

HDLC Inversion

Selectable V.35 data inversion

Transmit Timing Basis

Network selected-source timing

Receive Timing Basis

SCT, inverted SCT, SCTE

Receive Line Data Not Valid

RLSD, CTS

Connector

Female 34-pin V.35 connector

Line Rate

1.544 Mbps ±50 bps

o

o

o

o

o

o

o

o

collection and network performance monitor-

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and ana-

send alerts when services are not met.

investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

Line Format

AMI or B8ZS

Framing

ESF or D4 (SF)

Input Signal

-1dB to -11dB

Line Equalization

0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft

Connector

RJ-45

Channel Selection

1 to 24 channels in any combination

Specifications

19200 or 9600 bps baud rate, 8 data bits no parity,
1 stop bit, EIA RS-232 DTE electrical format, RJ-45
connector

Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777

Bite Rate

10 or 100 Mbps

Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

Connector

8-pin modular jack: RJ-48

N E T W O R K S U P E R V I S I O N

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643395 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0110

T1 CSU/DSU ASE
The Visual UpTime® Select™ T1 CSU/DSU ASE is

IP Transport software for deployment in frame relay or

Key features

deployed on a T1 access line at the demarcation point

• Inband management capabilities

between the provider network and customer premises.

• Multi-Protocol or IP Transport software

It supports full and fractional (FT1) T1 networks and

functions—such as BER tests, loopbacks, and power

• Service Level Agreement (SLA) metrics

provides connectivity through V.35 interface.

failure detection—the ASE is capable of inserting

• Voice over IP (VoIP) analysis capability
• Application analysis capability

The ASE supports Multi-Protocol software for deploy-

HDLC-based networks that use IP switching.
In addition to performing standard CSU/DSU

management traffic.

ment in standard frame relay or HDLC networks and

• LMI spoofing
• LAN management port
• Power loss detection
• Realtime events

T1 CSU/DSU model 807-0110 front view

T1 CSU/DSU model 807-0110 rear view

Demarcation Point

Wide Area
Network

T1 Access
Line

V.35
Line
CSU/DSU
ASE
Optional LAN
Connection

T1 CSU/DSU model 807-0110 position on network

Technical Data

Visual
UpTime
Select
Server

What are ASEs?

T1 CSU/DSU ASE specifcations
General

Environment

Power Requirements

T1 Network Interface

Network DTE Interface
(Data Port)

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply.

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

ing hardware devices placed on a wide area

Data Rate

1.544 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the T1 network or DSX-1
interface, or internally from the ASE.

as part of the Visual UpTime Select system,

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 90%, noncondensing

Input

100 to 120 VAC

lyzed from the Visual UpTime Select Web client.

Frequency

50/60 Hz

As a service level management tool, ASEs

Input Current Rating

0.5 amps

indicate when services are being met, provide

Line Rate

1.544 Mbps ±50 bps synchronous

warnings when services start to degrade, and

Line Format

AMI or B9ZS line coding

Framing

ESF or D4 framing formats

ESF FDL

ANSI T1.403, AT&T TR54016, Both, or None

Hardware Warranties

Input Signal

0dB to -36dB

Enhanced Gold, Bronze, and International

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Gold ASE hardware warranty service programs

Pulse Density

AT&T 62411

are available to help you maximize your

Connector

8-pin modular jack—USOC: RJ48C

Timing

Loop, DSX-1, or Internal

Channel Selection

1 to 24 channels in any combination

Configuration

DCE for interfacing with DTE

Data and Clock Leads

ITU-T V.35

Ordering Information

Signaling Leads

EIA RS-232 (ITU-T V.28)

For more details, please contact your Visual

Data Rates

56 kbps x N or 64 kbps x N (N = 1 through 24)

UpTime Select authorized reseller or

HDLC Inversion

Selectable V.35 data inversion

Transmit Timing Basis

Network selected-source timing

Receive Timing Basis

SCT, inverted SCT, SCTE

Receive Line Data Not Valid

RLSD, CTS

o

o

o

o

o

o

o

o

collection and network performance monitor-

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and ana-

Connector

Female 34-pin V.35 connector

Serial Port Interface

Specifications

19200 or 9600 bps baud rate, 8 data bits no parity,
1 stop bit, EIA RS-232 DTE electrical format, RJ-45
connector

Ethernet 10/100BaseT
Interface

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

send alerts when services are not met.

investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643388 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0111

T1 CSU/DSU ASE
With Modem
The Visual UpTime® Select™ T1 CSU/DSU ASE is

This ASE features an internal modem that allows

Key features

deployed on a T1 access line at the demarcation point

users to establish a telephone connection to either

• Inband management capabilities

between the provider network and customer premises.

the ASE’s administrative interface or a pass-through

• Multi-Protocol or IP Transport software

It supports full and fractional (FT1) T1 networks and

connection through the serial port.

• Service Level Agreement (SLA) metrics

provides connectivity through V.35 interface.

• Drop-and-Insert capabilities through
DSX port
• Internal modem

In addition to performing standard CSU/DSU

The ASE supports Multi-Protocol software for deploy-

functions—such as BER tests, loopbacks, and power

ment in standard frame relay or HDLC networks and

failure detection—the ASE is capable of inserting

IP Transport software for deployment in networks that

management traffic.

use IP switching.

• Voice over IP (VoIP) analysis capability
• Application analysis capability
• LMI spoofing
• LAN management port
• Power loss detection
• Realtime events

T1 CSU/DSU model 807-0111 front view

T1 CSU/DSU model 807-0111 rear view

Wide Area
Network

T1 Access
Line

CSU/DSU
ASE

V.35
Line

Modem
Connection

Optional LAN
Connection
PBX

PBX

T l h
T1 CSU/DSU model 807-0111 position on network

Technical Data

Visual
UpTime
Select
Server

What are ASEs?

T1 CSU/DSU ASE specifcations
General

Environment

Power Requirements

T1 Network Interface

Network DTE Interface
(Data Port)

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply.

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

ing hardware devices placed on a wide area

Data Rate

1.544 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the T1 network or DSX-1
interface, or internally from the ASE.

as part of the Visual UpTime Select system,

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 90%, noncondensing

Input

100 to 120 VAC

lyzed from the Visual UpTime Select Web client.

Frequency

50/60 Hz

As a service level management tool, ASEs

Input Current Rating

0.5 amps

indicate when services are being met, provide

Line Rate

1.544 Mbps ±50 bps synchronous

warnings when services start to degrade, and

Line Format

AMI or B9ZS line coding

Framing

ESF or D4 framing formats

ESF FDL

ANSI T1.403, AT&T TR54016, Both, or None

Hardware Warranties

Input Signal

0dB to -36dB

Enhanced Gold, Bronze, and International

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Gold ASE hardware warranty service programs

Pulse Density

AT&T 62411

are available to help you maximize your

Connector

8-pin modular jack—USOC: RJ48C

Timing

Loop, DSX-1, or Internal

Channel Selection

1 to 24 channels in any combination

Configuration

DCE for interfacing with DTE

Data and Clock Leads

ITU-T V.35

Ordering Information

Signaling Leads

EIA RS-232 (ITU-T V.28)

For more details, please contact your Visual

Data Rates

56 kbps x N or 64 kbps x N (N = 1 through 24)

UpTime Select authorized reseller or

HDLC Inversion

Selectable V.35 data inversion

Transmit Timing Basis

Network selected-source timing

Receive Timing Basis

SCT, inverted SCT, SCTE

Receive Line Data Not Valid

RLSD, CTS

o

o

o

o

o

o

o

o

collection and network performance monitor-

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and ana-

Connector

Female 34-pin V.35 connector

Serial Port Interface

Specifications

19200 or 9600 bps baud rate, 8 data bits no parity,
1 stop bit, EIA RS-232 DTE electrical format, RJ-45
connector

Ethernet 10/100BaseT
Interface

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

Modem

Connector

RJ11

Standard

FCC Part 68 and IC-CS03

Compliance

US and Canada

send alerts when services are not met.

investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643374 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0112

T1 CSU/DSU ASE
With DSX-1, Drop-and-Insert, and Modem
The Visual UpTime® Select™ T1 CSU/DSU ASE is

The ASE’s “drop-and-insert” feature provides a

Key features

deployed on a T1 access line at the demarcation point

secondary DSX-1 port that can connect to a Private

• Inband management capabilities

between the provider network and customer premises.

Branch Exchange at a customer’s site. T1 Timeslots

• Multi-Protocol or IP Transport software

It supports full and fractional (FT1) T1 networks and

can be segmented for a PBX on the same circuit

• Service Level Agreement (SLA) metrics

provides connectivity through V.35 and additional

carrying data traffic (see figure). The ASE’s internal

digital cross connect signal (DSX-1) interfaces.

modem lets users establish a telephone connection

• Drop-and-Insert capabilities through
DSX port
• Internal modem
• Voice over IP (VoIP) analysis capability

The ASE supports Multi-Protocol software for deploy-

to either the ASE’s administrative interface or a pass-

ment in standard frame relay or HDLC networks and IP

through connection via the serial port.

Transport software for deployment in networks that
use IP switching.

• Application analysis capability
• LMI spoofing
• LAN management port
• Power loss detection
• Realtime events

T1 CSU/DSU model 807-0112 front view

T1 CSU/DSU model 807-0112 rear view

Wide Area
Network

T1 Access
Line

CSU/DSU
ASE

V.35
Line

Modem
Connection

Optional LAN
Connection
PBX

PBX

T l h
T1 CSU/DSU model 807-0112 position on network

Technical Data

Visual
UpTime
Select
Server

What are ASEs?

T1 CSU/DSU ASE specifcations
General

Environment

Power Requirements

T1 Network Interface

Network DTE Interface
(Data Port)

DSX-1 Interface

Serial Port Interface

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply.

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

ing hardware devices placed on a wide area

Data Rate

1.544 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the T1 network or DSX-1
interface, or internally from the ASE.

as part of the Visual UpTime Select system,

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating/Storage Humidity

10% to 90%, noncondensing

data gathered by ASEs is stored in the Visual

Input

100 to 120 VAC

UpTime Select server and displayed and ana-

Frequency

50/60 Hz

lyzed from the Visual UpTime Select Web client.

Input Current Rating

0.5 amps

As a service level management tool, ASEs

Line Rate

1.544 Mbps ±50 bps synchronous

indicate when services are being met, provide

Line Format

AMI or B9ZS line coding

warnings when services start to degrade, and

Framing

ESF or D4 framing formats

send alerts when services are not met.

ESF FDL

ANSI T1.403, AT&T TR54016, Both, or None

Input Signal

0dB to -36dB

Hardware Warranties

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Enhanced Gold, Bronze, and International

Pulse Density

AT&T 62411

Gold ASE hardware warranty service programs

Connector

8-pin modular jack—USOC: RJ48C

are available to help you maximize your

Timing

Loop, DSX-1, or Internal

investment in Visual UpTime Select. For more

Channel Selection

1 to 24 channels in any combination

detailed warranty information, visit:

Configuration

DCE for interfacing with DTE

www.flukenetworks.com/visualcustomercare

Data and Clock Leads

ITU-T V.35

Signaling Leads

EIA RS-232 (ITU-T V.28)

Ordering Information

Data Rates

56 kbps x N or 64 kbps x N (N = 1 through 24)

For more details, please contact your Visual

HDLC Inversion

Selectable V.35 data inversion

UpTime Select authorized reseller or

Transmit Timing Basis

Network selected-source timing

Fluke Networks Sales at (800) 240-4010

Receive Timing Basis

SCT, inverted SCT, SCTE

or (301) 296-2300.

Receive Line Data Not Valid

RLSD, CTS

Connector

Female 34-pin V.35 connector

Line Rate

1.544 Mbps ±50 bps

o

o

o

o

o

o

o

o

Line Format

AMI or B8ZS

Framing

ESF or D4 (SF)

Input Signal

-1dB to -11dB

Line Equalization

0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft

Connector

RJ-45

Channel Selection

1 to 24 channels in any combination

Specifications

19200 or 9600 bps baud rate, 8 data bits no parity,
1 stop bit, EIA RS-232 DTE electrical format, RJ-45
connector

Ethernet 10/100BaseT
Interface

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

Modem

Specifications

RJ11 connector, FCC Part 68 and IC-CS03 standards,
compliance in US and Canada

collection and network performance monitor-

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,

N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 2643363 D-ENG-N Rev A

Visual UpTime Select
ASE model 807-0100

Dual-port Dual-analysis ASE
T1 CSU/DSU with DSX-1 and Drop-and-Insert capabilities
The Visual UpTime® Select™ Dual-port Dual-analysis

separate frame relay ports (for example, voice over

Key features

T1 CSU/DSU ASE is deployed on a T1 access line at the

FR1, plus SNA over FR2). In addition, domestic and

• Inband management capabilities

demarcation point between the provider network and

international frame relay services can exist on two

• Multi-Protocol or IP Transport software

customer premises. It supports frame relay/HDLC and

separate ports on the same access line.

• Service Level Agreement (SLA) metrics

IP Transport capabilities.

• Drop-and-Insert capabilities through
DSX port
• Voice over IP (VoIP) analysis capability
• Application analysis capability

In addition to performing standard CSU/DSU

This unit combines two model 109 T1 CSU/DSU ASEs

functions—such as BER tests, loopbacks, and power

with a built-in connector cable and analyzes data on

failure detection—the ASE is capable of inserting

both ports. The unit’s second port can be used for

management traffic. Up to 155 PVCs or IP circuits can

a redundant router in the event of primary router

be managed per ASE.

failure. Multiple traffic types can be concentrated on

• LMI spoofing
• LAN management port
• Second analysis port for redundant
router, different traffic types
• Power loss detection
• Realtime events

T1 CSU/DSU model 807-0109 front view (ASE model 100 is two model 109 units in a rack mount)
ASE 1

ASE 2

DSX

T1

ASE 2 PORT 2

ASE 1 PORT 1

T1-DSX Cable (801-0096)

T1 CSU/DSU model 807-0100 rear view

Wide Area
Network

Optional LAN
Connection on
data 1

CSU/DSU
Dual-port ASE

PBX
DSX-1

V.35 Ports
data 1

T1 CSU/DSU model 807-0100 on network

Technical Data

data 2

PBX

What are ASEs?

T1 CSU/DSU ASE specifcations
General

Environment

Power Requirements

T1 Network Interface

Network DTE Interface
(Data Port)

DSX-1 Interface

Serial Port Interface

Ethernet 10/100BaseT
Interface

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply.

ASEs (Analysis Service Elements) are data

Weight

2.10 lbs.

ing hardware devices placed on a wide area

Data Rate

1.544 Mbps synchronous

network (WAN) or Local Area Network (LAN)

Timing Mode

Derived externally from the T1 network or DSX-1
interface, or internally from the ASE.

as part of the Visual UpTime Select system,

Operating Temperature

0 to +40 C (+32 to +104 F)

Storage Temperature

-20 to +55 C (-4 to +131 ×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage
Humidity

10% to 90%, noncondensing

Input

100 to 240 VAC

lyzed from the Visual UpTime Select Web client.

Frequency

50/60 Hz

As a service level management tool, ASEs

Input Current Rating

0.5 amps

indicate when services are being met, provide

Line Rate

1.544 Mbps ±50 bps synchronous

warnings when services start to degrade, and

Line Format

AMI or B9ZS line coding

Framing

ESF or D4 framing formats

ESF FDL

ANSI T1.403, AT&T TR54016, Both, or None

Hardware Warranties

Input Signal

0dB to -36dB

Enhanced Gold, Bronze, and International

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Gold ASE hardware warranty service programs

Pulse Density

AT&T 62411

are available to help you maximize your

Connector

8-pin modular jack—USOC: RJ48C

Timing

Loop, DSX-1, or Internal

Channel Selection

1 to 24 channels in any combination

Configuration

DCE for interfacing with DTE

Data and Clock Leads

ITU-T V.35

Ordering Information

Signaling Leads

EIA RS-232 (ITU-T V.28)

For more details, please contact your Visual

Data Rates

56 kbps x N or 64 kbps x N (N = 1 through 24)

UpTime Select authorized reseller or

HDLC Inversion

Selectable V.35 data inversion

Transmit Timing Basis

Network selected-source timing

Receive Timing Basis

SCT, inverted SCT, SCTE

Receive Line Data Not Valid

RLSD, CTS

Connector

Female 34-pin V.35 connector

Line Rate

1.544 Mbps ±50 bps

o

o

o

o

o

o

o

o

collection and network performance monitor-

which offers in-depth, real-time, and historical
visibility into the performance of your
applications infrastructure. In the system,
data gathered by ASEs is stored in the Visual
UpTime Select server and displayed and ana-

Line Format

AMI or B8ZS

Framing

ESF or D4 (SF)

Input Signal

-1dB to -11dB

Line Equalization

0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft

send alerts when services are not met.

investment in Visual UpTime Select. For more
detailed warranty information, visit:
www.flukenetworks.com/visualcustomercare

Fluke Networks Sales at (800) 240-4010
or (301) 296-2300.

Connector

RJ-45

Channel Selection

1 to 24 channels in any combination

Specifications

19200 or 9600 bps baud rate, 8 data bits no parity,
1 stop bit, EIA RS-232 DTE electrical format, RJ-45
connector

Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777

Bite Rate

10 or 100 Mbps

Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details, go to
www.flukenetworks.com/contact.

Connector

8-pin modular jack: RJ-48

N E T W O R K S U P E R V I S I O N

©2006 Fluke Corporation. All rights reserved.

Printed in U.S.A. 2/2006 264xxxx D-ENG-N Rev A



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Modify Date                     : 2006:08:16 14:16:13-04:00
Create Date                     : 2006:08:16 14:08:41-04:00
Metadata Date                   : 2006:08:16 14:16:13-04:00
Creator Tool                    : PScript5.dll Version 5.2
Format                          : application/pdf
Title                           : Datasheet_4xT1_E1.indd
Creator                         : jburbrid
Document ID                     : uuid:55e2837c-a3bc-4b46-b099-984e16d30929
Instance ID                     : uuid:6ceece0b-4c4f-4c1f-bf9f-444d9e6a3efc
Producer                        : Acrobat Distiller 7.0 (Windows)
Page Count                      : 34
Author                          : jburbrid
EXIF Metadata provided by EXIF.tools

Navigation menu