Fluke Telescope 196C Users Manual 0MASTER
196C to the manual e5fa9b22-82fc-4314-b1ed-442c8ae1bd40
2015-02-02
: Fluke Fluke-Fluke-Telescope-196C-Users-Manual-427902 fluke-fluke-telescope-196c-users-manual-427902 fluke pdf
Open the PDF directly: View PDF .
Page Count: 118
Download | |
Open PDF In Browser | View PDF |
Fluke 196C/199C ScopeMeter Users Manual 4822 872 30482 October 2001 © 2001 Fluke Corporation. All rights reserved. Printed in the Netherlands. All product names are trademarks of their respective companies. LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke Corporation, P.O. Box 9090, Everett, WA 98206-9090 USA, or Fluke Industrial B.V., P.O. Box 90, 7600 AB, Almelo, The Netherlands SERVICE CENTERS To locate an authorized service center, visit us on the World Wide Web: http://www.fluke.com or call Fluke using any of the phone numbers listed below: +1-888-993-5853 in U.S.A. and Canada +31-40-2675200 in Europe +1-425-446-5500 from other countries Table of Contents Chapter Title Page Unpacking the Test Tool Kit........................................................................................ 2 Safety Information: Read First ....................................................................................... 4 1 Using The Scope .......................................................................................................... 7 Powering the Test Tool .................................................................................................. Resetting the Test Tool .................................................................................................. Navigating a Menu ......................................................................................................... Hiding Key Labels and Menus ....................................................................................... Input Connections .......................................................................................................... Making Scope Connections ........................................................................................... Displaying an Unknown Signal with Connect-and-View™ ............................................. Making Automatic Scope Measurements....................................................................... Freezing the Screen....................................................................................................... Using Average, Persistence and Glitch Capture............................................................ Acquiring Waveforms..................................................................................................... i 7 8 9 10 10 11 12 13 14 15 18 Fluke 196C/199C Users Manual Analyzing Waveforms .................................................................................................... 22 2 Using The Multimeter .................................................................................................. 23 Making Meter Connections ............................................................................................ Making Multimeter Measurements ................................................................................. Freezing the Readings................................................................................................... Selecting Auto/Manual Ranges...................................................................................... Making Relative Measurements..................................................................................... 3 Using The Recorder Functions................................................................................... 29 Opening the Recorder Main Menu ................................................................................. Plotting Measurements Over Time (TrendPlot™) .......................................................... Recording Scope Waveforms In Deep Memory (Scope Record) .................................. Analyzing a TrendPlot or Scope Record ........................................................................ 4 23 24 27 27 28 29 30 33 36 Using Replay, Zoom and Cursors............................................................................... 37 Replaying the 100 Most Recent Scope Screens ........................................................... 37 Zooming in on a Waveform............................................................................................ 40 Making Cursor Measurements ....................................................................................... 42 5 Triggering on Waveforms............................................................................................ 45 Setting Trigger Level and Slope..................................................................................... Using Trigger Delay or Pre-trigger ................................................................................. Automatic Trigger Options ............................................................................................. Triggering on Edges....................................................................................................... Triggering on External Waveforms ................................................................................ ii 46 47 48 49 52 Contents (continued) Triggering on Video Signals ........................................................................................... 53 Triggering on Pulses ...................................................................................................... 55 6 Using Memory, PC and Printer.................................................................................... 59 Saving and Recalling ..................................................................................................... 59 Documenting Screens.................................................................................................... 63 7 Tips................................................................................................................................ 67 Using the Standard Accessories .................................................................................... Using the Independently Floating Isolated Inputs .......................................................... Using the Tilt Stand........................................................................................................ Resetting the Test Tool .................................................................................................. Suppressing Key Labels and Menu’s............................................................................. Changing the Information Language.............................................................................. Adjusting the Contrast and Brightness........................................................................... Changing the Display Color ........................................................................................... To set the display to color or Black and White, do the following:................................... Changing Date and Time ............................................................................................... Saving Battery Life ......................................................................................................... Changing the Auto Set Options...................................................................................... 8 67 70 72 72 72 73 73 74 74 74 75 76 Maintaining the Test Tool............................................................................................ 77 Cleaning the Test Tool ................................................................................................... Storing the Test Tool...................................................................................................... Charging the Batteries ................................................................................................... Extending Battery Operation Time ................................................................................. Replacing the NiMH Battery Pack BP190 ...................................................................... Calibrating the Voltage Probes ...................................................................................... iii 77 77 78 79 80 80 Fluke 196C/199C Users Manual Displaying Calibration Information ................................................................................. 82 Parts and Accessories ................................................................................................... 82 Troubleshooting ............................................................................................................. 87 9 Specifications............................................................................................................... 89 Introduction .................................................................................................................... Dual Input Oscilloscope ................................................................................................. Automatic Scope Measurements ................................................................................... Meter.............................................................................................................................. DMM Measurements on Meter Inputs ............................................................................ Recorder ........................................................................................................................ Zoom, Replay and Cursors ............................................................................................ Miscellaneous ................................................................................................................ Environmental ................................................................................................................ Safety ..................................................................................................................... 10:1 Probe ..................................................................................................................... Electromagnetic Immunity.............................................................................................. iv 89 90 92 96 96 98 99 99 101 102 103 105 Unpacking the Test Tool Kit Declaration of Conformity for Fluke 196C/199C ScopeMeter® test tools Manufacturer Fluke Industrial B.V. Lelyweg 1 7602 EA Almelo The Netherlands Statement of Conformity Based on test results using appropriate standards, the product is in conformity with Electromagnetic Compatibility Directive 89/336/EEC Low Voltage Directive 73/23/EEC Sample tests Standards used: EN 61010.1 (1993) Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use EN-IEC61326-1 (1997) Electrical equipment for measurements and laboratory use -EMC requirements- The tests have been performed in a typical configuration. This Conformity is indicated by the symbol i.e. “Conformité Européenne”. , 1 Fluke 196C/199C Users Manual Unpacking the Test Tool Kit Note The following items are included in your test tool kit: When new, the rechargeable NiMH battery is not fully charged. See Chapter 8. Figure 1. ScopeMeter Test Tool Kit 2 Unpacking the Test Tool Kit # Description # Description 1 ScopeMeter Test Tool 7 2 Battery Charger (country dependent) 3 10:1 Voltage Probe Set (red) a) 10:1 Voltage Probe (red) b) Hook Clip for Probe Tip (red) c) Ground Lead with Hook Clip (red) d) Ground Lead with Mini Alligator Clip (black) e) 4-mm Test Probe for Probe Tip (red) f) Ground Spring for Probe Tip (black) Accessory Set a) 2-mm Test Probe for Probe Tip (gray) b) Industrial Alligator for Probe Tip (gray) c) 2-mm Test Probe for Banana Jack (gray) d) Industrial Alligator for Banana Jack (gray) e) Ground Lead with 4-mm Banana Jack (black) 8 Getting Started Manual 9 CD ROM with Users Manual (multi-language) 10 Shipment box (basic version only) 4 10:1 Voltage Probe Set (gray) a) 10:1 Voltage Probe (gray) b) Hook Clip for Probe Tip (gray) c) Ground Lead with Hook Clip (gray) d) Ground Lead with Mini Alligator Clip (black) e) 4-mm Test Probe for Probe Tip (gray) 5 Test Leads (red and black) 6 Accessory Set a) 2-mm Test Probe for Probe Tip (red) b) Industrial Alligator for Probe Tip (red) c) 2-mm Test Probe for Banana Jack (red) d) Industrial Alligator for Banana Jack (red) e) Ground Lead with 4-mm Banana Jack (black) Fluke 196C-S and 199C-S versions include also the following items: # Description 11 Optically Isolated RS-232 Adapter/Cable 12 FlukeView ScopeMeter Software for ® Windows 13 Hard Case ® ® 3 Fluke 196C/199C Users Manual Safety Information: Read First Carefully read the following safety information before using the test tool. Specific warning and caution statements, where they apply, appear throughout the manual. A “Warning” identifies conditions and actions that pose hazard(s) to the user. A “Caution” identifies conditions and actions that may damage the test tool. The following international symbols are used on the test tool and in this manual: 4 See explanation in manual Double Insulation (Protection Class) Disposal information Earth Recycling information Conformité Européenne Safety Approval Safety Approval Direct Current Alternating Current Warning To avoid electrical shock or fire: • Use only the Fluke power supply, Model BC190 (Battery Charger / Power Adapter). • Before use check that the selected/indicated range on the BC190 matches the local line power voltage and frequency. • For the BC190/808 universal Battery Charger / Power Adapter) only use line cords that comply with the local safety regulations. Note: To accomodate connection to various line power sockets, the BC190/808 universal Battery Charger / Power Adapter is equipped with a male plug that must be connected to a line cord appropriate for local use. Since the adapter is isolated, the line cord does not need to be equipped with a terminal for connection to protective ground. Since line cords with a protective grounding terminal are more commonly available you might consider using these anyhow. Safety Information: Read First Warning To avoid electrical shock or fire if a test tool input is connected to more than 42 V peak (30 Vrms) or on circuits of more than 4800 VA: • Use only insulated voltage probes, test leads and adapters supplied with the test tool, or indicated by Fluke as suitable for the Fluke190 ScopeMeter series. • Before use, inspect voltage probes, test leads and accessories for mechanical damage and replace when damaged. • Remove all probes, test leads and accessories that are not in use. • Always connect the battery charger first to the ac outlet before connecting it to the test tool. • Do not connect the ground spring (figure 1, item f) to voltages higher than 42 V peak (30 Vrms) from earth ground. • Do not apply voltages that differ more than 600 V from earth ground to any input when measuring in a CAT III environment. Do not apply voltages that differ more than 1000 V from earth ground to any input when measuring in a CAT II environment. • Do not apply voltages that differ more than 600 V from each other to the isolated inputs when measuring in a CAT III environment. Do not apply voltages that differ more than 1000 V from each other to the isolated inputs when measuring in a CAT II environment. • Do not apply input voltages above the rating of the instrument. Use caution when using 1:1 test leads because the probe tip voltage will be directly transmitted to the test tool. • Do not use exposed metal BNC or banana plug connectors. • Do not insert metal objects into connectors. • Always use the test tool only in the manner specified. Voltage ratings that are mentioned in the warnings, are given as limits for “working voltage”. They represent V ac rms (50-60 Hz) for ac sinewave applications and as V dc for dc applications. Overvoltage Category III refers to distribution level and fixed installation circuits inside a building. Overvoltage Category II refers to local level, which is applicable for appliances and portable equipment. 5 Fluke 196C/199C Users Manual The terms ‘Isolated’ or ‘Electrically floating’ are used in this manual to indicate a measurement in which the test tool input BNC or banana jack is connected to a voltage different from earth ground. The isolated input connectors have no exposed metal and are fully insulated to protect against electrical shock. The red and gray BNC jacks, and the red and black 4-mm banana jacks can independently be connected to a voltage above earth ground for isolated (electrically floating) measurements and are rated up to 1000 Vrms CAT II and 600 Vrms CAT III above earth ground. 6 If Safety Features are Impaired Use of the test tool in a manner not specified may impair the protection provided by the equipment. Before use, inspect the test leads for mechanical damage and replace damaged test leads! Whenever it is likely that safety has been impaired, the test tool must be turned off and disconnected from the line power. The matter should then be referred to qualified personnel. Safety is likely to be impaired if, for example, the test tool fails to perform the intended measurements or shows visible damage. Chapter 1 Using The Scope About this Chapter This chapter provides a step-by-step introduction to the scope functions of the test tool. The introduction does not cover all of the capabilities of the scope functions but gives basic examples to show how to use the menus and perform basic operations. Powering the Test Tool Follow the procedure (steps 1 through 3) in Figure 2 to power the test tool from a standard ac outlet. See Chapter 8 for instructions on using battery power. Turn the test tool on with the on/off key. The test tool powers up in its last setup configuration. Figure 2. Powering the Test Tool 7 Fluke 196C/199C Users Manual Resetting the Test Tool If you want to reset the test tool to the factory settings, do the following: 1 Turn the test tool off. 2 Press and hold the USER key. 3 Press and release. The test tool turns on, and you should hear a double beep, indicating the reset was successful. 4 Release the USER key. Now look at the display; you will see a screen that looks like Figure 3. 8 Figure 3. The Screen After Reset Using The Scope Navigating a Menu 1 Navigating a Menu The following example shows how to use the test tool's menus to select a function. Subsequently follow steps 1 through 4 to open the scope menu and to choose an item. 1 Press the SCOPE key to display the labels that define the present use for the four blue function keys at the bottom of the screen. Figure 4. Basic Navigation Note To hide the labels for full screen view, press the SCOPE key again. This toggling enables you to check the labels without affecting your settings. 2 Open the Waveform Options menu. This menu is displayed at the bottom of the screen. 3a 3b 4 Use the blue arrow keys to highlight the item. Press the blue ENTER key to accept the selection. Press the ENTER key until you exit the menu. Note lets you to step Repeatedly pressing through a menu without changing the settings. 9 Fluke 196C/199C Users Manual Hiding Key Labels and Menus Input Connections You can hide a menu or key label at any time: Look at the top of the test tool. The test tool has four signal inputs: two safety BNC jack inputs (red input A and gray input B) and two safety 4-mm banana jack inputs (red and black). Use the two BNC jack inputs for scope measurements, and the two banana jack inputs for meter measurements. Press the CLEAR MENU key to hide any key label or menu. To display menus or key labels, press one of the yellow menu keys, e.g. the SCOPE key. Isolated input architecture allows independent floating measurements with each input. Figure 5. Measurement Connections 10 Using The Scope Making Scope Connections 1 Making Scope Connections To make dual input scope measurements, connect the red voltage probe to input A, and the gray voltage probe to input B. Connect the short ground leads of each voltage probe to its own reference potential. (See Figure 6.) Note To maximally benefit from having independently isolated floating inputs and to avoid problems caused by improper use, read Chapter 7: “Tips”. Figure 6. Scope Connections 11 Fluke 196C/199C Users Manual Displaying an Unknown Signal with Connect-and-View™ The Connect-and-View feature lets the test tool display complex, unknown signals automatically. This function optimizes the position, range, time base, and triggering and assures a stable display of virtually any waveform. If the signal changes, the setup is automatically adjusted to maintain the best display result. This feature is especially useful for quickly checking several signals. To enable the Connect-and-View feature, do the following: 1 Perform an Auto Set. AUTO appears at the top right of the screen. The bottom line shows the range, the time base, and the trigger information. The waveform identifier (A) is visible on the bottom right side of the screen, as shown in Figure 7. The input A zero icon ( ) at the left side of the screen identifies the ground level of the waveform. - 2 12 Press a second time to select the manual range again. MANUAL appears at the top right of the screen. Figure 7. The Screen After an Auto Set Use the light-gray RANGE, TIME and MOVE keys at the bottom of the keypad to change the view of the waveform manually. Using The Scope Making Automatic Scope Measurements Making Automatic Scope Measurements The test tool offers a wide range of automatic scope measurements. You can display two numeric readings: READING 1 and READING 2. These readings are selectable independently, and the measurements can be done on the input A or input B waveform To choose a frequency measurement for input A, do the following: 1 Display the SCOPE key labels. 2 Open the Reading 1 menu. 3 Select on A. Observe that the highlight jumps to the present measurement. 4 Select the Hz measurement. 1 Observe that the top left of the screen displays the Hz measurement. (See Figure 8.) To choose also a Peak-Peak measurement for Input B as second reading, do the following: 1 Display the SCOPE key labels. 2 Open the Reading 2 menu. 3 Select on B. The highlight jumps to the measurements field. 4 Open the PEAK menu. 5 Select the Peak-Peak measurement. 13 Fluke 196C/199C Users Manual Figure 8 shows an example of the screen. Note that the Peak-Peak reading for input B appears next to the input A frequency reading at the top of the screen. Figure 8. Hz and V peak-peak as Scope Readings 14 Freezing the Screen You can freeze the screen (all readings and waveforms) at any time. 1 Freeze the screen. HOLD appears at the right of the reading area. 2 Resume your measurement. Using The Scope Using Average, Persistence and Glitch Capture Using Average, Persistence and Glitch Capture Using Average for Smoothing Waveforms To smooth the waveform, do the following: 1 Display the SCOPE key labels. 2 Open the Waveform Options menu. 3 Jump to Average: 4 Select On... to open the Average Factors menu 5 Select Average 64.This averages the outcomes of 64 acquisitions. 6 Exit the menu. 1 You can use the average functions to suppress random or uncorrelated noise in the waveform without loss of bandwidth. Waveform samples with and without smoothing are shown in Figure 9. Figure 9. Smoothing a Waveform 15 Fluke 196C/199C Users Manual Using Persistence to Display Waveforms You can use Persistence to observe dynamic signals. 1 Display the SCOPE key labels. 2 Open the Waveform Options menu. 3 Jump to Waveform: and open the Persistence... menu. Figure 10. Using Persistence to Observe Dynamic Signals When you select Envelope: On, the test tool displays the upper and lower boundaries of dynamic waveforms. 4 16 Select Digital Persistence: Infinite, Envelope: Off. Start monitoring the waveform. Using The Scope Using Average, Persistence and Glitch Capture 1 Displaying Glitches Suppressing High Frequency Noise To capture glitches on a waveform, do the following: Switching Glitch Detect to Off will suppress the high frequency noise on a waveform. Averaging will suppress the noise even more. 1 Display the SCOPE key labels. 2 Open the Waveform Options menu. 3 4 1 Display the SCOPE key labels. 2 Open the Waveform Options menu. 3 Select Glitch Detect: Off, then select Average: On to open the Average menu 4 Select Factor : 8x Select Glitch Detect: On Exit the menu. You can use this function to display events (glitches or other asynchronous waveforms) of 50 ns (nanoseconds) or wider, or you can display HF modulated waveforms. Tip Glitch capture and average do not affect bandwidth. Further noise suppression is possible with bandwidth limiting filters. See Chapter 1: “Working with Noisy Waveforms”. 17 Fluke 196C/199C Users Manual Acquiring Waveforms Selecting AC-Coupling After a reset, the test tool is dc-coupled so that ac and dc voltages appear on the screen. Use ac-coupling when you wish to observe a small ac signal that rides on a dc signal. To select ac-coupling, do the following: 1 Display the INPUT A key labels. 2 Highlight AC. Observe that the bottom left of the screen displays the . ac-coupling icon: Reversing the Polarity of the Displayed Waveform To invert the input A waveform, do the following: 1 Display the INPUT A key labels. 2 Open the Input A menu. 3 Select Inverted and accept inverted waveform display. 4 Exit the menu. For example, a negative-going waveform is displayed as positive-going waveform which may provide a more meaningful view. An inverted display is identified by an ) at the right of the waveform. inversed trace identifier ( 18 Using The Scope Acquiring Waveforms Variable Input Sensitivity 4 Open the Input A Options... menu. 5 Select and accept Variable. 6 Exit the menu. The variable input sensitivity allows you to adjust the sensitivity continuously, for example to set the amplitude of a reference signal to exactly 6 divisions. The input sensitivity of a range can be increased up to 2.5 times, for example between 10 mV/div and 4 mV/div in the 10 mV/div range. 1 To use the variable input sensitivity, do the following: 1 2 Apply the input signal Perform an Auto Set (AUTO must appear at the top of the screen) An Auto Set will turn off the variable input sensitivity. You can now select the required input range. Keep in mind that the sensitivity will increase when you start adjusting the variable sensitivity (the displayed trace amplitude will increase). 3 At the bottom left of the screen the text A Var is displayed. Selecting Variable will turn off cursors and automatic input ranging. 7 Press mV to increase the sensitivity, press V to decrease the sensitivity. Display the INPUT A key labels. 19 Fluke 196C/199C Users Manual Working with Noisy Waveforms Using Waveform Mathematics Functions To suppress high frequency noise on waveforms, you can limit the working bandwidth to 10 kHz or 20 MHz. This function smoothes the displayed waveform. For the same reason, it improves triggering on the waveform. When adding (A+B), subtracting (A-B), or multiplying (A*B) the input A and input B waveform, the test tool will display the mathematical result waveform and the input A and input B waveforms. To choose HF reject, do the following: A versus B provides a plot with input A on the vertical axis and input B on the horizontal axis. 1 Display the INPUT A key labels. The Mathematics functions perform a point-to-point operation on waveforms A and B. 2 Open the Input A menu. 3 Jump to Bandwidth. 4 Select 10kHz (HF reject) to accept the bandwidth limitation. Tip To suppress noise without loss of bandwidth, use the average function or turn off Display Glitches. 20 To use a Mathematics function, do the following: 1 Display the SCOPE key labels. 2 Open the Waveform Options menu. Using The Scope Acquiring Waveforms 3 Jump to Waveform: and Select Mathematics... to open the Mathematics menu. 1 Comparing Waveforms You can display a fixed reference waveform with the actual waveform for comparison. To create a reference waveform and to display it with the actual waveform, do the following: 4 5 Select Function: A+B, A-B, A*B or A vs B. 1 Display the SCOPE key labels. 2 Open the Waveform Options menu. 3 Jump to Reference: and accept New. The momentary waveform is stored and permanently displayed. The display also shows the actual waveform. Select a scale factor to fit the mathematical result waveform onto the display, and return. The sensitivity range of the mathematical result is equal to the sensitivity range of the least sensitive input divided by the scale factor. To recall a saved waveform from memory and use it as a reference waveform refer to Chapter 6 Recalling Screens with Associated Setups. 21 Fluke 196C/199C Users Manual Analyzing Waveforms You can use the analysis functions CURSOR, ZOOM and REPLAY to perform detailed waveform analysis. These functions are described in Chapter 4: “Using Cursors, Zoom and Replay”. 22 Chapter 2 Using The Multimeter About this Chapter This chapter provides a step-by-step introduction to the multimeter functions of the test tool (hereafter called “meter”). The introduction gives basic examples to show how to use the menus and perform basic operations. Making Meter Connections Use the two 4-mm safety red ( ) and black (COM) banana jack inputs for the Meter functions. (See Figure 11.) Figure 11. Meter Connections Note Typical use of the Meter test leads and accessories is shown in Chapter 7. 23 Fluke 196C/199C Users Manual Making Multimeter Measurements The screen displays the numeric readings of the measurements on the meter input. The resistor value is displayed in ohms. Observe also that the bargraph is displayed. (See Figure 12.) Measuring Resistance Values To measure a resistance, do the following: 1 Connect the red and black test leads from the 4-mm banana jack inputs to the resistor. 2 Display the METER key labels. 3 Open the Measurement menu. Figure 12. Resistor Value Readings 4 Highlight Ohms. 5 Select Ohms measurement. 24 Using The Multimeter Making Multimeter Measurements 2 Making a Current Measurement You can measure current in both Scope mode and Meter mode. Scope mode has the advantage of two waveforms being displayed while you perform measurements. Meter mode has the advantage of high measurement resolution. The next example explains a typical current measurement in Meter mode. Warning Carefully read the instructions about the current probe you are using. Figure 13. Measurement Setup 3 Open the Measurement menu. 4 Highlight A ac.... 5 Open the Current Probe submenu. To set up the test tool, do the following: 1 Connect a current probe (e.g. i400, optional) from the 4-mm banana jack outputs to the conductor to be measured. Ensure that the red and black probe connectors correspond to the red and black banana jack inputs. (See Figure 13.) 2 Display the METER key labels. 25 Fluke 196C/199C Users Manual 6 Observe the sensitivity of the current probe. Highlight the corresponding sensitivity in the menu, e.g. 10 mV/A. 7 Accept the current measurement. Now, you will see a screen like in Figure 14. Figure 14. Ampere Measurement Readings 26 Using The Multimeter Freezing the Readings 2 Freezing the Readings Selecting Auto/Manual Ranges You can freeze the displayed readings at any time. To activate manual ranging, do the following during any Meter measurement: 1 2 Freeze the screen. HOLD appears at the top right of the reading area. Resume your measurement. 1 Activate manual ranging. 2 Increase or decrease the range. Observe how the bargraph sensitivity changes. You can use this function to hold accurate readings for later examination. Note For saving screens into memory, see Chapter 6. Use manual ranging to set a fixed bargraph sensitivity and decimal point. 3 Choose auto ranging again. When in auto ranging, the bargraph sensitivity and decimal point are automatically adjusted while checking different signals. 27 Fluke 196C/199C Users Manual Making Relative Measurements A relative measurement displays the present measurement result relative to a defined reference value. Observe that the main reading is displayed as variations from the reference value. The actual reading with its bargraph is displayed beneath these readings. (See Figure 15.) The following example shows how to perform a relative voltage measurement. First obtain a reference value: 1 Display the METER key labels. 2 Measure a voltage to be used as reference value. 3 Set RELATIVE to ON. (ON is highlighted.) This stores the reference value as reference for subsequent measurements. The stored reference value is displayed in small digits at the bottom right side of the screen after the word REFERENCE. 4 28 Measure the voltage to be compared to the reference. Figure 15. Making a Relative Measurement You can use this feature when, for example, you need to monitor input activity (voltage, resistance, temperature) in relation to a known good value. Chapter 3 Using The Recorder Functions About this Chapter This chapter provides a step-by-step introduction to the recorder functions of the test tool. The introduction gives examples to show how to use the menus and perform basic operations. Opening the Recorder Main Menu First choose a measurement in scope or meter mode. Now you can choose the recorder functions from the recorder main menu. To open the main menu, do the following: 1 Open the RECORDER main menu. (See Figure 16.) Figure 16. Recorder Main Menu 29 Fluke 196C/199C Users Manual Plotting Measurements Over Time (TrendPlot™) Use the TrendPlot function to plot a graph of Scope or Meter measurements as function of time. Starting a TrendPlot Function To start plotting a graph of the reading over time, do the following: 1 Apply a signal to the red BNC input A and turn on Reading 1 in scope mode 2 Open the RECORDER main menu. 3 Highlight Trend Plot (Scope). 4 Start the TrendPlot recording. Note Because the navigations for the dual input TrendPlot (Scope) and the single input TrendPlot (Meter) are identical, only TrendPlot (Scope) is explained in the next sections. The test tool continuously records the digital readings of the input A measurements and displays these as a graph. The TrendPlot graph rolls from right to left like a paper chart recorder. Observe that the recorded time from start appears at the bottom of the screen. The present reading appears on top of the screen. (See Figure 17.) Note When simultaneously TrendPlotting two readings, the screen area is split into two sections of four divisions each. 30 Using The Recorder Functions Plotting Measurements Over Time (TrendPlot™) 3 Displaying Recorded Data When in normal view (NORMAL), only the nine most recently recorded divisions are displayed on screen. All previous recordings are stored in memory. VIEW ALL shows 7 all data in memory: Display an overview of the full waveform. Press repeatedly to toggle between normal view (NORMAL) and overview (VIEW ALL) Figure 17. TrendPlot Reading When the Scope is in automatic mode, automatic vertical scaling is used to fit the TrendPlot graph on the screen. 5 Set RECORDER to STOP to freeze the recorder function. 6 Set RECORDER to RUN to continue. When the recorder memory is full, an automatic compression algorithm is used to compress all samples into half of the memory without loss of transients. The other half of the recorder memory is free again to continue recording. 31 Fluke 196C/199C Users Manual Changing the Recorder Options At the right bottom of the display you can choose to display the time elapsed from start and the actual time of the day. To change the time reference, proceed from step 6 as follows: 7 Open the Recorder Options menu. 8 Select Time of Day and jump to the next field. Now the recorded time and the current time appear at the bottom of the screen. The options Reading 1 and Reading 2 allow you to select the scope readings to be recorded. (Or one meter measurement when in TrendPlot meter mode.) 32 To continue without making further changes: 9 Close. Turning Off the TrendPlot Display 10 Exit the recorder function. Using The Recorder Functions Recording Scope Waveforms In Deep Memory (Scope Record) 3 Recording Scope Waveforms In Deep Memory (Scope Record) The SCOPE RECORD function is a roll mode that logs one or two long waveforms. This function can be used to monitor waveforms like motion control signals or the power-on event of an Uninterruptable Power Supply (UPS). During recording, fast transients are captured. Because of the deep memory, recording can be done for more than one day. This function is similar to the roll mode in many DSO’s but has deeper memory and better functionality. Starting a Scope Record Function 1 2 3 Figure 18. Recording Waveforms Apply a signal to the red BNC input A. From the Recorder main menu, highlight Scope Record. Observe that the top of the screen displays the following: • Time from start at the top of the screen. Start the recording. • The status at the bottom of the screen which includes the time/div setting as well as the total timespan that fits the memory. The waveform moves across the screen from right to left like a normal chart recorder. (See Figure 18.) Note For accurate recordings it is advised to let the instrument first warm up for five minutes. 33 Fluke 196C/199C Users Manual Displaying Recorded Data Using ScopeRecord in Single Sweep Mode In Normal view, the samples that roll off the screen are stored in deep memory. When the memory is full, recording continues by shifting the data in memory and deleting the first samples out of memory. Use the recorder Single Sweep function to automatically stop recording when the deep memory is full. In View All mode, the complete memory contents are displayed on the screen. 4 4 Open the Recorder options menu. Press to toggle between VIEW ALL (overview of all recorded samples) and NORMAL view. You can analyze the recorded waveforms using the Cursors and Zoom functions. See Chapter 4: “Using Replay, Zoom and Cursors”. 34 Continue from step 3 of the previous section: 5 6 (2x) Jump to the Mode field. Select Single Sweep and accept the recorder options. Using The Recorder Functions Recording Scope Waveforms In Deep Memory (Scope Record) 3 Using External Triggering to Start or Stop Scope Record To record an electrical event that causes a fault, it might be useful to start or stop recording on an external trigger signal: Start on Trigger to start recording; recording stops when the deep memory is full Stop on Trigger to stop recording. Run When Triggered to continue recording as long as a next trigger comes within 1 division in view all mode. Figure 19. Scope Record Using External Triggering To set up the test tool, continue from step 3 of the previous section: 6 Jump to Display Glitches:. 7 Jump to Mode:. 8 Select on EXT. ... to open the Single Sweep on Ext. menu. 9 Select one of the Conditions: and jump to Slope:. 4 5 Apply the signal to be recorded to the red BNC input A. Apply a trigger signal to the red and black external trigger banana inputs. (See Figure 19.) Open the Recorder Options menu. 35 Fluke 196C/199C Users Manual 10 Select the desired trigger slope, and jump to Level: 11 Select the 0.12V or 1.2 V trigger level and accept all recorder options. During recording samples are continuously saved in deep memory. The last nine recorded divisions are displayed on the screen. Use View All to display the full memory contents. Note To learn more about the Single Shot trigger function, see Chapter 5 “Triggering on Waveforms”. Figure 20. Triggered Single Sweep Recording Analyzing a TrendPlot or Scope Record From a Scope TrendPlot or Scope Record you can use the analysis functions CURSORS and ZOOM to perform detailed waveform analysis. These functions are described in Chapter 4: “Using Replay, Zoom and Cursors”. 36 Chapter 4 Using Replay, Zoom and Cursors About this Chapter This chapter covers the capabilities of the analysis functions Cursor, Zoom, and Replay. These functions can be used with one or more of the primary functions Scope, TrendPlot or Scope Record. It is possible to combine two or three analysis functions. A typical application using these functions follows: • First replay the last screens to find the screen of special interest. • Then zoom in on the signal event. • Finally, make measurements using the cursors. Replaying the 100 Most Recent Scope Screens When you are in scope mode, the test tool automatically stores the 100 most recent screens. When you press the HOLD key or the REPLAY key, the memory contents are frozen. Use the functions in the REPLAY menu to “go back in time” by stepping through the stored screens to find the screen of your interest. This feature lets you capture and view signals even if you did not press HOLD. 37 Fluke 196C/199C Users Manual Replaying Step-by-Step To step through the last scope screens, do the following: 1 From scope mode, open the REPLAY menu. Observe that the trace is frozen and that REPLAY appears at the top of the screen (see Figure 21). 2 Step through the previous screens. 3 Step through the next screens. Observe that the bottom of the waveform area displays the replay bar with a screen number and related time stamp: Figure 21. Replaying a Waveform The replay bar represents all 100 stored screens in memory. The icon represents the picture being displayed on the screen (in this example: SCREEN -84). If the bar is partly white, the memory is not completely filled with 100 screens. From this point you can use the zoom and cursor functions to study the signal in more detail. 38 Using Replay, Zoom and Cursors Replaying the 100 Most Recent Scope Screens Replaying Continuously You can also replay the stored screens continuously, like playing a video tape. To replay continuously, do the following: 1 From Scope mode, open the REPLAY menu. Observe that the trace is frozen and REPLAY appears at the top of the screen. 2 Continuously replay the stored screens in ascending order. Wait until the screen with the signal event of interest appears. 3 4 Turning Off the Replay Function 4 Turn off REPLAY. Capturing 100 Intermittents Automatically When you use the test tool in triggered mode, 100 triggered screens are captured. This way you could use Pulse Triggering to trigger and capture 100 intermittent glitches or you could use External Triggering to capture 100 UPS startups. By combining the trigger possibilities with the capability of capturing 100 screens for later replay, you can leave the test tool unattended to capture intermittent signal anomalies. For triggering, see Chapter 5: “Triggering on Waveforms”. Stop the continuous replay. 39 Fluke 196C/199C Users Manual Zooming in on a Waveform To obtain a more detailed view of a waveform, you can zoom in on a waveform using the ZOOM function. To zoom in on a waveform, do the following: 1 Display the ZOOM key labels. Observe that the trace is frozen, HOLD appears at the top of the screen, and the waveform is magnified. 2 Enlarge (decrease the time/div) or shrink (increase the time/div) the waveform. 3 Scroll. A position bar displays the position of the zoomed part in relation to the total waveform. Tip Even when the key labels are not displayed at the bottom of the screen, you can still use the arrow keys to zoom in and out. 40 Figure 22. Zooming in a Waveform Observe that the bottom of the waveform area displays the zoom ratio, position bar, and time/div (see Figure 22). The zoom range depends on the amount of data samples stored in memory. From this point you can use the cursor function for further measurements on the waveform. Using Replay, Zoom and Cursors Zooming in on a Waveform Displaying the Zoomed Waveform The VIEW ALL feature is useful when you quickly need to see the complete waveform and then return to the zoomed part. 4 4 Turning Off the Zoom Function 5 Turn off the ZOOM function. Display the complete waveform. Press repeatedly to toggle between the zoomed part of the waveform and the complete waveform. 41 Fluke 196C/199C Users Manual Making Cursor Measurements Cursors allow you to make precise digital measurements on waveforms. This can be done on live waveforms, recorded waveforms, and on saved waveforms. Note Even when the key labels are not displayed at the bottom of the screen, you still can use the arrow keys. This allows full control of both cursors while having full screen view. Using Horizontal Cursors on a Waveform To use the cursors for a voltage measurement, do the following: 1 From scope mode, display the cursor key labels. 2 Press to highlight . Observe that two horizontal cursors are displayed. 3 Highlight the upper cursor. 4 Move the upper cursor to the desired position on the screen. 5 Highlight the lower cursor. 6 Move the lower cursor to the desired position on the screen. 42 Figure 23. Voltage Measurement with Cursors The screen shows the voltage difference between the two cursors and the voltage at the cursors. (See Figure 23.) Use horizontal cursors to measure the amplitude, high or low value, or overshoot of a waveform. Using Replay, Zoom and Cursors Making Cursor Measurements 4 Using Vertical Cursors on a Waveform To use the cursors for a time measurement, do the following: 1 From scope mode, display the cursor key labels. 2 Press to highlight . Observe that two vertical cursors are displayed. Markers (—) identify the point where the cursors cross the waveform. 3 If necessary, choose the trace: TRACE A ,B, or M (Mathematics). 4 Highlight the left cursor. 5 Move the left cursor to the desired position on the waveform. 6 Highlight the right cursor. Figure 24. Time Measurement with Cursors 7 Move the right cursor to the desired position on the waveform. The screen shows the time difference between the cursors and the voltage difference between the two markers. (See Figure 24.) 8 Turn off the cursors. 43 Fluke 196C/199C Users Manual Using Cursors on a A+B, A-B or A*B Waveform Cursor measurements on a A*B waveform give a reading in Watts if input A measures (milli)Volts and input B measures (milli)Amperes. For other cursor measurements on a A+B, A-B or A*B waveform no reading will be available if the input A and input B measurement unit are different. Making Rise Time Measurements To measure rise time, do the following: 1 From scope mode, display the cursor key labels. 2 Press to highlight (rise time). Observe that two horizontal cursors are displayed. 3 If only one trace is displayed, select MANUAL or AUTO (this automatically does steps 4 to 6). For multiple traces select the required trace A, B, or M (if a math function is active). 44 4 Move the upper cursor to 100% of the trace height. A marker is shown at 90%. 5 Highlight the other cursor. 6 Move the lower cursor to 0% of the trace height. A marker is shown at 10%. The reading shows the risetime from 10%-90% of the trace amplitude. Figure 25. Risetime Measurement Chapter 5 Triggering on Waveforms About this Chapter • This chapter provides an introduction to the trigger functions of the test tool. Triggering tells the test tool when to begin displaying the waveform. You can use fully automatic triggering, take control of one or more main trigger functions (semi-automatic triggering), or you can use dedicated trigger functions to capture special waveforms. If the signal is unstable or has a very low frequency, you can control the trigger level, slope, and trigger delay for a better view of the signal. (See next section.) • For dedicated applications, use one of the four manual trigger functions: Following are some typical trigger applications: • Use the Connect-and-View™ function to have full automatic triggering and instant display of virtually any waveform. • Edge triggering • External triggering • Video triggering • Pulse Width triggering 45 Fluke 196C/199C Users Manual Setting Trigger Level and Slope The Connect-and-View™ function enables hands-off triggering to display complex unknown signals. When your test tool is in manual range, do the following: Perform an auto set. AUTO appears at the top right of the screen. Automatic triggering assures a stable display of virtually any signal. From this point, you can take over the basic trigger controls such as level, slope and delay. To optimize trigger level and slope manually, do the following: 1 Display the TRIGGER key labels. Figure 26. Screen with all Trigger Information 4 Adjust the trigger level. Observe the trigger icon that indicates the trigger position, trigger level, and slope. 2 Trigger on either positive slope or negative slope of the chosen waveform. 3 Enable the arrow keys for manual trigger level adjustment. 46 At the bottom of the screen the trigger parameters are displayed. (See Figure 26.) For example, means that input A is used as the trigger source with a positive slope. When no trigger is found, the trigger parameters appear in gray. Triggering on Waveforms Using Trigger Delay or Pre-trigger 5 Using Trigger Delay or Pre-trigger You can begin to display the waveform some time before or after the trigger point has been detected. Initially, you have 2 divisions of pre-trigger view (negative delay). To set the trigger delay, do the following: 5 Hold down to adjust the trigger delay. Observe that the trigger icon on the screen moves to show the new trigger position. When the trigger position moves left off of the screen, the trigger icon changes into to indicate that you have selected a trigger delay. Moving the trigger icon to the right on the display gives you a pre-trigger view. Figure 27. Trigger Delay or Pre-trigger View Figure 27 shows an example of a trigger delay of 500 ms (top) and an example of pre-trigger view of 8 divisions (bottom). In case of a trigger delay, the status at the bottom of the screen will change. For example: This means that input A is used as the trigger source with a positive slope. The 500.0 ms indicates the (positive) delay between trigger point and waveform display. When no trigger is found, the trigger parameters appear in gray. 47 Fluke 196C/199C Users Manual Automatic Trigger Options In the trigger menu, settings for automatic triggering can be changed as follows. (See also Chapter 1: “Displaying an Unknown Signal with Connect-and-View”) 1 Display the TRIGGER key labels. Note The TRIGGER key labels can differ depending on the latest trigger function used. 2 Open the Trigger Options menu. 3 Open the Automatic Trigger menu. 48 If the frequency range of the automatic triggering is set to > 15 Hz, the Connect-and-View™ function responds more quickly. The response is quicker because the test tool is instructed not to analyze low frequency signal components. However, when you measure frequencies lower than 15 Hz, the test tool must be instructed to analyze low frequency components for automatic triggering: 4 Select > 1 HZ and return to the measurement screen. Triggering on Waveforms Triggering on Edges Triggering on Edges If the signal is instable or has a very low frequency, use edge triggering to obtain full manual trigger control. To trigger on rising edges of the input A waveform, do the following: 5 When Free Run is selected, the test tool updates the screen even if there are no triggers. A trace always appears on the screen. When On Trigger is selected, the test tool needs a trigger to display a waveform. Use this mode if you want to update the screen only when valid triggers occur. 1 Display the TRIGGER key labels. When Single Shot is selected, the test tool waits for a trigger. After receiving a trigger, the waveform is displayed and the instruments is set to HOLD. 2 Open the Trigger Options menu. In most cases it is advised to use the Free Run mode: 3 Open the Trigger on Edge menu. 4 Select Free Run, jump to Noise reject Filter. 5 Set Noise reject Filter to Off. Observe that the key labels at the bottom of the screen have adapted to allow further selection of specific edge trigger settings: 49 Fluke 196C/199C Users Manual Triggering on Noisy Waveforms Making a Single Acquisition To reduce jitter on the screen when triggering on noisy waveforms, you can use a noise rejection filter. Continue from step 3 of the previous example as follows: To catch single events, you can perform a single shot acquisition (one-time screen update). To set up the test tool for a single shot of the input A waveform, continue from step 3 again: 4 5 Select On Trigger, jump to Noise reject Filter. Select Single Shot. 5 Accept the settings. Set Noise reject Filter to On. Observe that the trigger gap has increased. This is indicated by a taller trigger icon . 50 4 The word WAITING appears at the top of the screen indicating that the test tool is waiting for a trigger. As soon as the test tool receives a trigger, the waveform is displayed and the instrument is set to hold. This is indicated by the word HOLD at top of the screen. Triggering on Waveforms Triggering on Edges 5 The test tool will now have a screen like Figure 28. 6 Arm the test tool for a new single shot. Tip The test tool stores all single shots in the replay memory. Use the Replay function to look at all the stored single shots. Figure 28. Making a Single Shot Measurement 51 Fluke 196C/199C Users Manual Triggering on External Waveforms Use external triggering when you want to display waveforms on inputs A and B while triggering on a third signal. You can choose external triggering with automatic triggering or with edge triggering. 1 Supply a signal to the red and black 4-mm banana jack inputs. See Figure 29. In this example you continue from the Trigger on Edges example. To choose the external signal as trigger source, continue as follows: 2 3 Display the TRIGGER (On Edges) key labels. Select Ext (external) edge trigger. Observe that the key labels at the bottom of the screen have been adapted to allow selection of two different external trigger levels: 0.12 V and 1.2 V: 52 Figure 29. External Triggering 4 Select 1.2V under the Ext LEVEL label. From this point the trigger level is fixed and is compatible with logic signals. Triggering on Waveforms Triggering on Video Signals 5 Triggering on Video Signals To trigger on a video signal, first select the standard of the video signal you are going to measure: 1 Apply a video signal to the red input A. 2 Display the TRIGGER key labels. 3 Open the Trigger Options menu. Figure 30. Measuring Interlaced Video Signals 4 Select Video on A to open the Trigger on Video menu. 6 Select the video standard and return. Trigger level and slope are now fixed. 5 Select positive signal polarity for video signals with negative going sync pulses. Observe that the key labels at the bottom of the screen have been changed to allow further selection of specific video trigger settings: 53 Fluke 196C/199C Users Manual Triggering on Video Frames Triggering on Video Lines Use FIELD 1 or FIELD 2 to trigger either on the first half of the frame (odd) or on the second half of the frame (even). Use ALL LINES to trigger on all line synchronization pulses (horizontal synchronization). To trigger on the second half of the frame, do the following: 7 Choose FIELD 2. The signal part of the even field is displayed on the screen. 7 Choose ALL LINES. The signal of one line is displayed on the screen. The screen is updated with the signal of the next line immediately after the test tool triggers on the horizontal synchronization pulse. To view a specific video line in more detail, you can select the line number. For example, to measure on video line 123, continue from step 6 as follows: 7 Enable video line selection. 8 Select number 123. The signal of line 123 is displayed on the screen. Observe that the status line now also shows the selected line number. The screen is continuously updated with the signal of line 123. 54 Triggering on Waveforms Triggering on Pulses 5 Triggering on Pulses Use pulse width triggering to isolate and display specific pulses that you can qualify by time, such as glitches, missing pulses, bursts or signal dropouts. 4 Select Pulse Width on A... to open the Trigger on Pulse Width menu. 5 Select the positive pulse icon, then jump to Condition. 6 Selectt, then jump to Update. 6 Select On Trigger. 5 The test tool is now prepared to trigger on pulse gaps. Observe that the trigger menu at the bottom of the screen has been adapted to set the pulse condition: 57 Fluke 196C/199C Users Manual To set the pulse width to 150 ms, continue as follows: 7 Enable the arrow keys to adjust the pulse width. 8 Select 150 ms. Figure 32. Triggering on Missing Pulses 58 Chapter 6 Using Memory, PC and Printer About this Chapter Saving and Recalling This chapter provides a step-by-step introduction to the general functions of the test tool that can be used in the three main modes: Scope, Meter, or Recorder. You will find information on printer and computer communication at the end of this chapter. You can: • Save screens and setups to memory, and recall them again from memory. The test tool has 10 screen and setup memories and 2 record and setup memories. • Recall screens and recordings to analyze or print the screen image at a later date. • Recall a setup to continue a measurement with the recalled operating configuration. 59 Fluke 196C/199C Users Manual Saving Screens with Associated Setups To save a screen in memory location 10, do the following: 1 Open the Save menu. Observe that free memory locations are indicated by an open square (). Filled memory locations are indicated by a solid square (). 60 Highlight SCREEN+SETUP location 10. 4 Save the actual screen. Display the SAVE/PRINT key labels. From this point the screen is frozen until you hide the SAVE/PRINT key labels again. 2 3 Note The two record+setup memory locations store more than what is just visible on the screen. In TrendPlot or scope record mode the full recording is saved. In scope mode you can save all 100 replay screens in a single record+setup memory location. Using Memory, PC and Printer Saving and Recalling Deleting Screens with Associated Setups Recalling Screens with Associated Setups To delete all screens and associated setups, continue from step 2 of the previous example as follows: To recall screen+setup 1, do the following: 3 6 1 Display the SAVE/PRINT key labels. 2 Open the Recall menu. 3 Highlight SCREEN+SETUP location 1. 4 Use RECALL to recall the saved screen. Delete all saved screens and setups. To delete only one screen and setup, continue from step 2 of the previous example as follows: 3 Highlight SCREEN+SETUP location 5. 4 Delete the saved screen+setup of memory location 5. Observe that the recalled waveform is displayed and that HOLD appears on the screen. From this point you can use cursors and zoom for analysis or you can print the recalled screen. To recall a sceen as a reference waveform to compare it with an actually measured waveform, continue from step 3 as follows: 61 Fluke 196C/199C Users Manual 4 5 Use RECALL FOR REFERENCE to recall the saved screen. Resume the measurement. Both, the reference screen and the measurement screen will be displayed. Recalling a Setup Configuration To recall the setup configuration from memory 1, do the following: 1 Display the SAVE/PRINT key labels. 2 Open the Recall menu. 3 Highlight SCREEN+SETUP location 1. 4 Use RECALL SETUP to recall the saved setup. Observe that RUN appears at the top right of the screen. From this point you continue in the new operating configuration. 62 Using Memory, PC and Printer Documenting Screens 6 Viewing Stored Screens Documenting Screens To scroll through the memories while looking at the stored screens, do the following: With the FlukeView software you can upload waveform data and screen bitmaps to your PC or notebook computer for further processing. Printing can also be done by connecting the test tool directly to a printer. 1 Display the SAVE/PRINT key labels. ® Connecting to a Computer 2 Open the View... menu. To connect the test tool to a PC or notebook computer ® and use the FlukeView software for Windows (SW90W), do the following: 3 Highlight a screen location, and view the screen properties. 4 View the screen, and open the viewer. 5 Scroll through all stored screens. Use the Optically Isolated RS-232 Adapter/Cable (PM9080) to connect a computer to the OPTICAL PORT of the test tool. (See Figure 33.) Figure 33. Connecting a Computer 63 Fluke 196C/199C Users Manual Note For information about installing and using the FlukeView ScopeMeter software, see the SW90W Users Manual. A Software & Cable Carrying Case Kit is optionally available as model number SCC190. Connecting to a Printer To print a screen directly to a printer, use one of the following adapters: The Optically Isolated RS-232 Adapter/Cable (PM9080) to connect a serial printer to the OPTICAL PORT of the test tool. (See Figure 34.) The Print Adapter Cable (PAC91, optional) to connect a parallel printer to the OPTICAL PORT of the test tool. (See Figure 35.) Before printing, you must setup the test tool for a specific printer. 64 Figure 34. Connecting a Serial Printer Figure 35. Connecting a Parallel Printer Using Memory, PC and Printer Documenting Screens Setting up the Printing Configuration This example demonstrates how to set up the test tool for printing on a postscript printer with a 9600 baud rate: 1 Display the USER OPTIONS key labels. 6 Whenever possible, choose the option Postscript when printing screens. This option gives the best printing results. Consult the manual that came with your printer to find out whether it has Postscript printing possibilities. Printing a Screen To print the currently displayed screen, do the following: 2 3 1 Clear the menu if you do not want to print it. 2 Display the SAVE/PRINT key labels. 3 Start printing. Open the User Options menu. Open the Printer Setup submenu. A message appears at the bottom of the screen indicating that the test tool is busy printing. Screens will be printed in black and white. 4 Select Postscript and jump to Baud Rate. 5 Select a baud rate of 9600 and return to normal mode. 65 Fluke 196C/199C Users Manual 66 Chapter 7 Tips About this Chapter Using the Standard Accessories This chapter gives you information and tips on how you can make the best use of the test tool. The following illustrations show the use of the standard accessories such as voltage probes, test leads, and the various clips. 67 Fluke 196C/199C Users Manual Figure 36. Probing Using 2-mm Heavy Duty Test Probes Warning Figure 38. Heavy Duty Fixed Connections for Scope Measurements Using Industrial Alligator Clips To avoid electrical shock or fire, do not connect the ground spring to voltages higher than 30 Vrms from earth ground. Figure 37. HF Voltage Probe Connection Using Ground Spring 68 Figure 39. Electronic Connections for Scope Measurements Using Hook Clips and Hook Clip Grounding Tips Using the Standard Accessories Figure 40. Electronic Connections for Scope Measurements Using Hook Clips and Alligator Clip Grounding Figure 41. Fixed Electronic Connections for Scope Measurements with Fixed External Triggering 7 Figure 42. Manual Probing for Meter Measurements using 2-mm Test Probes Figure 43. Heavy Duty Fixed Connections for Meter Measurements Using Industrial Alligator Clips 69 Fluke 196C/199C Users Manual Using the Independently Floating Isolated Inputs You can use the independently floating isolated inputs to measure signals that are independently floating from each other. Independently floating isolated inputs offer additional safety and measurement capabilities compared to inputs with common references or grounds. Measuring Using Independently Floating Isolated Inputs The test tool has independently floating isolated inputs. Each input section (A, B, External Trigger / DMM) has its own signal input and its own reference input. The reference input of each input section is electrically isolated from the reference inputs of the other input sections. The isolated input architecture makes the test tool about as versatile as having three independent instruments. The advantages of having independently floating isolated inputs are: • 70 It allows simultaneous measurement of independently floating signals. • Additional safety. Since the commons are not directly connected, the chance of causing short circuit when measuring multiple signals is greatly reduced. • Additional safety. When measuring in systems with multiple grounds, the ground currents induced are kept to a minimum. Because the references are not connected together inside the test tool, each reference of the used inputs must be connected to a reference voltage. Independently floating isolated inputs are still coupled by parasitic capacitance. This can occur between the input references and the environment, and between the input references mutually (see Figure 44). For this reason, you should connect the references to a system ground or another stable voltage. If the reference of an input is connected to a high speed and / or high voltage signal, you should be aware of parasitic capacitance. (See Figures 44, 45, 46 and 47.) Tips Using the Independently Floating Isolated Inputs ANALOG INPUT ANALOG GROUND Figure 44. Parasitic capacitance between probes, instrument and environment DC BUS MOTION/MOTOR CONTROLLER 7 DIGITAL CONTROLLER DIGITAL GROUND Figure 46. Correct connection of reference leads ANALOG INPUT DIGITAL CONTROLLER + ANALOG GROUND DIGITAL GROUND M DIGITAL GROUND DC BUS Figure 47. Wrong connection of reference leads Figure 45. Parasitic capacitance between analog and digital reference Noise that is picked up by reference lead B can be transmitted by parasitic capacitance to the analog input amplifier. 71 Fluke 196C/199C Users Manual Using the Tilt Stand Resetting the Test Tool The test tool is equipped with a tilt stand, allowing viewing from an angle while placed on a table. From this position you can access the OPTICAL PORT at the side of the test tool. The typical position is shown in Figure 48. If you want to reset the test tool to the factory settings, do the following: 1 Turn the test tool off. 2 Press and hold. 3 Press and release. The test tool turns on, and you should hear a double beep, indicating the reset was successful. 4 Release. Suppressing Key Labels and Menu’s You can hide a menu or key label at any time: Hide any key label or menu. Figure 48. Using the Tilt Stand 72 To display menus or key labels, press one of the yellow menu keys, e.g. the SCOPE key. Tips Changing the Information Language Changing the Information Language Adjusting the Contrast and Brightness During operation of the test tool, messages may appear at the bottom of the screen. You can select the language in which these messages are displayed. The combination of selectable languages (one or more) depends on the version ordered. To adjust the contrast and backlight brightness, do the following: In this example you can select English or French . To change the language from English to French, do the following: 1 2 Display the USER key labels. Open the Language Select menu. 3 Highlight FRENCH. 4 Accept French as the language. 7 1 Display the USER key labels. 2 Enable the arrow keys for manual contrast and backlight adjustment. 3 Adjust the contrast of the screen. 4 Change the backlight. Note The new contrast and brightness are stored until a new adjustment is made. To save battery power, the test tool is in economic brightness mode when operated on the battery. The high brightness intensity increases when you connect the power adapter. Note Using dimmed light lengthens maximum battery power operation by about one hour. 73 Fluke 196C/199C Users Manual Changing the Display Color Changing Date and Time To set the display to color or Black and White, do the following: The test tool has a date and time clock. For example, to change the date to 19 April, 2002, do the following: 1 Display the USER key labels. 1 Display the USER key labels. 2 Open the User Options menu. 2 Open the User Options menu. 3 Open Display Options menu. 3 Open Date Adjust menu. 4 Choose display mode Color or Black and White, and accept it. 4 Choose 2002, jump to Month. 5 Choose 04, jump to Day. 74 Tips Saving Battery Life 6 Choose 19, jump to Format. 7 Setting the Power Down Timer Initially the power shutdown time is 30 minutes. You can set the power shutdown time to 5 minutes as following: 7 Choose DD/MM/YY, accept the new date. You can change the time in a similar way by opening the Time Adjust menu (steps 2 and 3.) 1 Display the USER key labels. 2 Open the User Options menu. 3 Open the Battery Save Options menu. 4 Select 5 Minutes. Saving Battery Life When operated on the battery (no battery charger connected), the test tool conserves power by shutting itself down. If you have not pressed a key for at least 30 minutes, the test tool turns itself off automatically. Note If the power adapter is connected, there is no automatic power shutdown. Automatic power shutdown will not occur if TrendPlot or Scope Record is on, but the backlight will dim. Recording will continue even if the battery is low, and retention of memories is not jeopardized. 75 Fluke 196C/199C Users Manual Changing the Auto Set Options With the next procedure you can choose how auto set behaves when you press the AUTO (auto set) key. 1 Display the USER key labels. 2 Open the User Options menu. 4 Select Signal > 1 Hz, then jump to Coupling. With the coupling option you can choose how auto set behaves. When you press the AUTO (auto set) key, the coupling can either be set to dc or left unchanged: 5 Select Unchanged. Note 3 Open the Auto Set Adjust menu. If the frequency range is set to > 15 Hz, the Connect-andView function responds more quickly. The response is quicker because the test tool is instructed not to analyze low frequency signal components. However, when you measure frequencies lower than 15 Hz, the test tool must be instructed to analyze low frequency components for automatic triggering: 76 The auto set option for the signal frequency is similar to the automatic trigger option for the signal frequency. (See Chapter 5: “Automatic Trigger Options”). However, the auto set option determines the behavior of the auto set function and shows only effect when you press the auto set key. Chapter 8 Maintaining the Test Tool About this Chapter Cleaning the Test Tool This chapter covers basic maintenance procedures that can be performed by the user. For complete service, disassembly, repair, and calibration information, see the Service Manual. You will find the part number of the Service Manual in the section “Parts and Accessories” in this chapter. Clean the test tool with a damp cloth and a mild soap. Do not use abrasives, solvents, or alcohol. These may damage the text on the test tool. Storing the Test Tool If you are storing the test tool for an extended period of time, charge the NiMH (Nickel-Metal Hydride) batteries before storing. 77 Fluke 196C/199C Users Manual Charging the Batteries At delivery, the NiMH batteries may be empty and must be charged for 4 hours (with the test tool turned off) to reach full charge. When fully charged, the batteries provide 4 hours of use. When battery power is used, the battery indicator at the top of the screen informs you about the condition of the . The batteries. The battery symbols are: indicates that there are typically five minutes symbol of operating time left. To charge the batteries and power the instrument, connect the battery charger as shown in Figure 49. To charge the batteries more quickly, turn off the test tool. Caution To avoid overheating of the batteries during charging, do not exceed the allowable ambient temperature given in the specifications. Note No damage will occur if the charger is connected for long periods, e.g., during the weekend. The instrument then automatically switches to trickle charging. 78 Figure 49. Charging the Batteries Maintaining the Test Tool Extending Battery Operation Time Extending Battery Operation Time Typically, NiMH batteries always meet the specified operating time. However, if the batteries have been extremely discharged (for example, when empty batteries were stored for a long period) it is possible that the battery condition has deteriorated. 8 To refresh the battery, make sure that the test tool is line powered and proceed as follows: 1 Display the USER key labels. 2 Open the User Options menu. To keep the batteries in optimal condition, observe the following guidelines: • symbol Operate the test tool on batteries until the appears at the bottom of the screen. This indicates that the battery level is low and that the NiMH batteries need to be recharged. • To obtain optimal battery condition again, you can refresh the batteries. During a battery refresh, the batteries will be fully discharged and charged again. A complete refresh cycle takes about 12 hours and should be done about four times a year. You can check the latest battery refresh date. See section “Displaying Calibration Information”. A message appears asking whether you want to start the refresh cycle now. 3 Start the refresh cycle. Do not disconnect the battery charger during the refresh cycle. This will interrupt the refresh cycle. Note After starting the refresh cycle, the screen will be black. 79 Fluke 196C/199C Users Manual Replacing the NiMH Battery Pack BP190 Usually it should not be necessary to replace the battery pack. However, if replacement is needed, this should be done by qualified personnel only. Contact your nearest Fluke center for more information. Calibrating the Voltage Probes To meet full user specifications, you need to adjust the red and gray voltage probes for optimal response. The calibration consists of a high frequency adjustment and a dc calibration for 10:1 probes. The dc calibration is not possible for 100:1 probes. This example shows how to calibrate the 10:1 voltage probes: 1 Display the input A key labels. 2 Open the Probe on A menu. Figure 50. Adjusting Voltage Probes If the 10:1 option is already selected, proceed with step 5. 4 3 80 Select Voltage, then jump to Attenuation. Select 10:1, then return. Maintaining the Test Tool Calibrating the Voltage Probes Repeat steps 2 and 3 and proceed as follows: 5 Select Probe Cal with the arrow keys, then accept. A message appears asking you whether to start the 10:1 probe calibration. 6 Start the probe calibration. A message appears telling you how to connect the probe. Connect the red 10:1 voltage probe from the red input A jack to the red banana jack. Connect the reference lead to the black banana jack. (See Figure 50.) 7 Adjust the trimmer screw in the probe housing until a pure square wave is displayed. 8 Continue with DC calibration. Automatic DC calibration is only possible for 10:1 voltage probes. 8 The test tool automatically calibrates itself to the probe. During calibration you should not touch the probe. A message indicates when the DC calibration has completed successfully. 9 Return. Repeat the procedure for the gray 10:1 voltage probe. Connect the grey 10:1 voltage probe from the grey input B jack to the red banana jack. Connect the reference lead to the black banana jack. Note When using 100:1 voltage probes, choose 100:1 attenuation to perform a HF adjustment. Automatic dc calibration is not possible with this probe type. 81 Fluke 196C/199C Users Manual Displaying Calibration Information Parts and Accessories You can display version number and calibration date: Standard Accessories 1 Display the USER key labels. The following tables list the user-replaceable parts for the various test tool models. For additional optional accessories, see the ScopeMeter Accessories booklet. 2 Open the Version & Calibration menu. To order replacement parts or additional accessories, contact your nearest service center. The screen gives you information about the model number with software version, the calibration number with latest calibration date, and the latest battery refresh date. 3 Return. Recalibration must be carried out by qualified personnel. Contact your local Fluke representative for recalibration. 82 Maintaining the Test Tool Parts and Accessories 8 Table 1. Standard Accessories Item Ordering Code Battery Charger, available models: Universal Europe 230 V, 50 and 60 Hz North America 120 V, 50 and 60 Hz United Kingdom 240 V, 50 and 60 Hz Japan 100 V, 50 and 60 Hz Australia 240 V, 50 and 60 Hz Universal 115 V/230 V, 50 and 60 Hz * BC190/801 BC190/803 BC190/804 BC190/806 BC190/807 BC190/808 * The 230V rating of the BC190/808 is not for use in North America. A line plug adapter complying with the applicable National Requirements may be provided to alter the blade configurations for a specific country. The universal adapter is standard equipped with a North American line cord. Voltage Probe Set (Red), designed for use with the Fluke ScopeMeter 190 series test tool. The set includes the following items (not available separately): • 10:1 Voltage Probe (red) • 4-mm Test Probe for Probe Tip (red) • Hook Clip for Probe Tip (red) • Ground Lead with Hook Clip (red) • Ground Lead with Mini Alligator Clip (black) • Ground Spring for Probe Tip (black) VPS200-R 83 Fluke 196C/199C Users Manual Item Ordering Code Voltage Probe Set (Gray), designed for use with the Fluke ScopeMeter 190 series test tool. The set includes the following items (not available separately): • 10:1 Voltage Probe (gray) • 4-mm Test Probe for Probe Tip (gray) • Hook Clip for Probe Tip (gray) • Ground Lead with Hook Clip (gray) • Ground Lead with Mini Alligator Clip (black) VPS200-G Flexible Test Leads (red and black) TL24 (General Purpose Leads) Accessory Set (Red) AS200-R The set includes the following items (not available separately): • Industrial Alligator for Probe Tip (red) • 2-mm Test Probe for Probe Tip (red) • Industrial Alligator for Banana Jack (red) • 2-mm Test Probe for Banana Jack (red) • Ground Lead with 4-mm Banana Jack (black) Accessory Set (Gray) The set includes the following items (not available separately): • Industrial Alligator for Probe Tip (gray) • 2-mm Test Probe for Probe Tip (gray) • Industrial Alligator for Banana Jack (gray) • 2-mm Test Probe for Banana Jack (gray) • Ground Lead with 4-mm Banana Jack (black) 84 AS200-G Maintaining the Test Tool Parts and Accessories Item Ordering Code Replacement Set for Voltage Probe RS200 8 The set includes the following items (not available separately): • 2x 4-mm Test Probe for Probe Tip (red and gray) • 3x Hook Clip for Probe Tip (2 red, 1 gray) • 2x Ground Lead with Hook Clip (red and gray) • 2x Ground Lead with Mini Alligator Clip (black) • 5x Ground Spring for Probe Tip (black) Table 2. Users Manuals Item Ordering Code Getting Started Manual (English) 4822 872 30471 Getting Started Manual (German) 4822 872 30472 Getting Started Manual (French) 4822 872 30473 Getting Started Manual (Spanish) 4822 872 30474 Getting Started Manual (Portuguese) 4822 872 30475 Getting Started Manual (Italian) 4822 872 30476 Getting Started Manual (Chinese) 4822 872 30477 Getting Started Manual (Japanese) 4822 872 30478 Getting Started Manual (Korean) 4822 872 30479 CD ROM with User Manual (all languages) 4022 240 12371 85 Fluke 196C/199C Users Manual Optional Accessories Item Ordering Code Software & Cable Carrying Case Kit SCC190 Set contains the following parts: PM9080 Optically Isolated RS-232 Adapter/Cable C190 Hard Carrying Case ® ® ® ® ® FlukeView ScopeMeter Software for Windows 95 , 98 , Me , ® ® 2000 and NT4 SW90W Optically Isolated RS-232 Adapter/Cable PM9080 Hard Case C190 Soft Case C195 Current Shunt 4-20 mA CS20MA Print Adapter Cable for Parallel Printers PAC91 Optional Service Manual Item Ordering Code Service Manual (English) 4822 872 05384 86 Maintaining the Test Tool Troubleshooting 8 Troubleshooting The Test Tool Does Not Start Up • The batteries may be completely empty. In this case the test tool will not start up, even if it is powered by the battery charger. Charge the batteries first: power the test tool with the battery charger without turning it on. Wait about 15 minutes and try turning on the test tool again. The Test Tool Shuts Down After A Few Seconds • The batteries may be empty. Check the battery symbol symbol at the top right of the screen. A indicates that the batteries are empty and must be charged. The Screen Remains Black • Make sure that the test tool is on. • You might have a problem with the screen contrast. Press , then press . Now you can use The Operation Time Of Fully Charged Batteries Is Too Short • The batteries may be in poor condition. Refresh the batteries to optimize the condition of the batteries again. It is advised to refresh the batteries about four times a year. The Printer Does Not Print • Make sure that the interface cable is properly connected between the test tool and the printer. • Make sure that you have selected the correct printer type. (See Chapter 6.) • Make sure that the baud rate matches with the printer. If not, select another baud rate. (See Chapter 6.) • If you are using the PAC91 (Print Adapter Cable), make sure that it is turned on. the arrow keys to adjust the contrast. 87 Fluke 196C/199C Users Manual FlukeView Does Not Recognize The Test Tool • Make sure that the test tool is turned on. • Make sure that the interface cable is properly connected between the test tool and the PC. • Make sure that the correct COM port has been selected in FlukeView. If not, change the COM port setting or connect the interface cable to another COM port. Battery Operated Fluke Accessories Do Not Function • 88 When using battery operated Fluke accessories, always first check the battery condition of the accessory with a Fluke multimeter. Chapter 9 Specifications Introduction Performance Characteristics FLUKE guarantees the properties expressed in numerical values with the stated tolerance. Specified non-tolerance numerical values indicate those that could be nominally expected from the mean of a range of identical ScopeMeter test tools. Environmental Data The environmental data mentioned in this manual are based on the results of the manufacturer’s verification procedures. Safety Characteristics The test tool has been designed and tested in accordance with Standards ANSI/ISA S82.01-1994, EN 61010.1 (1993) (IEC 1010-1), CAN/CSA-C22.2 No.1010.1-92 (including approval), UL3111-1 (including approval) Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use. This manual contains information and warnings that must be followed by the user to ensure safe operation and to keep the instrument in a safe condition. Use of this equipment in a manner not specified by the manufacturer may impair protection provided by the equipment. 89 Fluke 196C/199C Users Manual Dual Input Oscilloscope Isolated Inputs A and B (Vertical) Bandwidth, DC Coupled FLUKE 199C ....................................... 200 MHz (-3 dB) FLUKE 196C ....................................... 100 MHz (-3 dB) Lower Frequency Limit, AC Coupled with 10:1 probe......................................... <2 Hz (-3 dB) direct (1:1) ................................................ <5 Hz (-3 dB) Rise Time FLUKE 199C ........................................................1.7 ns FLUKE 196C ........................................................3.5 ns Analog Bandwidth Limiters ............... 20 MHz and 10 kHz Input Coupling.......................................................AC, DC Polarity ................................................... Normal, Inverted Sensitivity Ranges with 10:1 probe.............................. 50 mV to 1000 V/div direct (1:1) ......................................... 5 mV to 100 V/div Trace Positioning Range................................±4 divisions Input Impedance on BNC DC Coupled........................1 MΩ (±1 %)//15 pF (±2 pF) 90 Max. Input Voltage with 10:1 probe .........................................600 V CAT III 1000 V CAT II direct (1:1) ................................................300 V CAT III (For detailed specifications, see “Safety”) Vertical Accuracy ..................... ±(1.5 % + 0.04 range/div) Digitizer Resolution .................... 8 bits, separate digitizer for each input Horizontal Maximum Time Base Speed: FLUKE 199C ..................................................... 5 ns/div FLUKE 196C ..................................................... 5 ns/div Minimum Time Base Speed (Scope Record) ..... 2 min/div Real Time Sampling Rate (for both inputs simultaneously) FLUKE199C: 5 ns to 2 µs /div ................................... up to 2.5 GS/s 5 µs to 120 s/div ............................................ 20 MS/s FLUKE 196C: 5 ns to 2 µs /div ...................................... up to 1 GS/s 5 µs to 120 s/div ............................................ 20 MS/s Specifications Dual Input Oscilloscope Record Length Scope Record Mode........... 27500 points on each input Scope Normal Mode............. 1000 points on each input Scope Glitch Capture Mode ... 500 points on each input 9 Trigger Level Control Range ......................... ±4 divisions Waveform Display................ A, B, A+B, A-B, A*B, A vs B Normal, Average (2,4,8,64 x), Persistence Trigger Sensitivity A and B DC to 5 MHz at >5 mV/div ......................... 0.5 divisions DC to 5 MHz at 5 mV/div ................................ 1 division 200 MHz (FLUKE 199C)................................. 1 division 250 MHz (FLUKE 199C)............................... 2 divisions 100 MHz (FLUKE 196C)................................. 1 division 150 MHz (FLUKE 196C)............................... 2 divisions Time Base Accuracy .........................................±100 ppm Isolated External Trigger Trigger and Delay Bandwidth.............................................................. 10 kHz Trigger Modes ....................................... Automatic, Edge, External, Video, Pulse Width Modes.....................................................Automatic, Edge Trigger Delay.................................. up to +1000 divisions Video Trigger Pre Trigger View ............................ one full screen length Standards ............................. PAL, PAL+, NTSC, SECAM Max. Delay ..................................................... 10 seconds Modes...................... Lines, Line Select, Field 1 or Field 2 Automatic Connect-and-View Trigger Source ............................................................................A Source...............................................................A, B, EXT Polarity ................................................ Positive, Negative Slope....................................................Positive, Negative Sensitivity ...................................... 0.7 division sync level Glitch Detection 5 µs to 120 s/div ........ displays glitches as fast as 50 ns Trigger Levels (DC to 10 kHz) ................... 120 mV, 1.2 V Edge Trigger Screen Update ........... Free Run, On Trigger, Single Shot Source...............................................................A, B, EXT Slope....................................................Positive, Negative 91 Fluke 196C/199C Users Manual Pulse Width Trigger Automatic Scope Measurements Screen Update ............................ On Trigger, Single Shot The accuracy of all readings is within ± (% of reading + number of counts) from 18 °C to 28 °C. Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe accuracy unless the probe has been calibrated on the test tool. At least 1.5 waveform period must be visible on the screen. Trigger Conditions............ T, =T (±10 %), ≠T(±10 %) Source............................................................................ A Polarity .....................................Positive or negative pulse Pulse Time Adjustment Range ......... 0.01 div. to 250 div. with a minimum of 300 ns ( T) or 500 ns (=T, ≠T), a maximum of 10 s, and a resolution of 0.01 div. with a minimum of 50 ns Continuous Auto Set Autoranging attenuators and time base, automatic Connect-and-View™ triggering with automatic source selection. Modes Normal.................................... 15 Hz to max. bandwidth Low Frequency......................... 1 Hz to max. bandwidth Minimum Amplitude A and B DC to 1 MHz........................................................ 10 mV 1 MHz to max. bandwidth.................................... 20 mV General Inputs ..................................................................... A and B DC Common Mode Rejection (CMRR).................. >100 dB AC Common Mode Rejection at 50, 60, or 400 Hz....... >60 dB DC Voltage (VDC) Maximum Voltage with 10:1 probe ..................................................... 1000 V direct (1:1) .............................................................. 300 V Maximum Resolution with 10:1 probe ........................................................ 1 mV direct (1:1) ............................................................ 100 µV Full Scale Reading .......................................... 1100 counts Automatic Capturing Scope Screens Accuracy at 5 s to 5 µs/div ................... ±(1.5 % +5 counts) Capacity ............................ 100 dual input scope Screens Normal Mode AC Rejection at 50 or 60 Hz ............ >60 dB For viewing screens, see Replay function. 92 Specifications Automatic Scope Measurements AC Voltage (VAC) 9 All accuracies are valid if: • The waveform amplitude is larger than one division • At least 1.5 waveform period is on the screen Maximum Voltage with 10:1 probe...................................................1000 V direct (1:1) ............................................................300 V AC+DC Voltage (True RMS) Maximum Resolution with 10:1 probe......................................................1 mV direct (1:1) ..........................................................100 µV Maximum Voltage with 10:1 probe .................................................. 1000 V direct (1:1) ........................................................... 300 V Full Scale Reading....................................... 1100 counts Maximum Resolution with 10:1 probe ..................................................... 1 mV direct (1:1) ......................................................... 100 µV Accuracy DC coupled: DC to 60 Hz ................................±(1.5 % +10 counts) AC coupled, low frequencies: 50 Hz direct (1:1) .......................±(2.1 % + 10 counts) 60 Hz direct (1:1) .......................±(1.9 % + 10 counts) With the 10:1 probe the low frequency roll off point will be lowered to 2 Hz, which improves the AC accuracy for low frequencies. When possible use DC coupling for maximum accuracy. Full Scale Reading ....................................... 1100 counts Accuracy DC to 60 Hz ................................. ±(1.5 % + 10 counts) 60 Hz to 20 kHz ........................... ±(2.5 % + 15 counts) 20 kHz to 1 MHz ............................. ±(5 % + 20 counts) 1 MHz to 25 MHz .......................... ±(10 % + 20 counts) For higher frequencies the instrument’s frequency roll off starts affecting accuracy. AC or DC coupled, high frequencies: 60 Hz to 20 kHz .........................±(2.5 % + 15 counts) 20 kHz to 1 MHz ...........................±(5 % + 20 counts) 1 MHz to 25 MHz ........................±(10 % + 20 counts) For higher frequencies the instrument’s frequency roll off starts affecting accuracy. Normal Mode DC Rejection.............................>50 dB 93 Fluke 196C/199C Users Manual Amperes (AMP) Frequency (Hz) With Optional Current Probe or Current Shunt Range......................................1.000 Hz to full bandwidth Ranges............................. same as VDC, VAC, VAC+DC Full Scale Reading ...................................... 9 999 counts with at least 10 waveform periods on screen. Probe Sensitivity .................100 µV/A, 1 mV/A, 10 mV/A, 100 mV/A, 1 V/A, 10 V/A, and 100 V/A Accuracy .......................... same as VDC, VAC, VAC+DC (add current probe or current shunt accuracy) Accuracy 1 Hz to full bandwidth ......................±(0.5 % +2 counts) Duty Cycle (DUTY) Peak Range..................................................... 4.0 % to 98.0 % Modes ........................... Max peak, Min peak, or pk-to-pk Pulse Width (PULSE) Maximum Voltage with 10:1 probe...................................................1000 V direct (1:1) ............................................................300 V Full Scale Reading ......................................... 999 counts Maximum Resolution with 10:1 probe....................................................10 mV direct (1:1) .............................................................1 mV Full Scale Reading..........................................800 counts Accuracy Max peak or Min peak ............................... ±0.2 division Peak-to-peak............................................. ±0.4 division 94 Resolution (with GLITCH off).........................1/100 division Accuracy 1 Hz to full bandwidth ......................±(0.5 % +2 counts) Specifications Automatic Scope Measurements Power Temperature (TEMP) Power Factor....................... ratio between Watts and VA Range......................................................... 0.00 to 1.00 With Optional Temperature Probe Watt .................................. RMS reading of multiplication corresponding samples of input A (volts) and Input B (amperes) Full Scale Reading ...................................... 999 counts VA ................................................................Vrms x Arms Full Scale Reading ...................................... 999 counts 2 2 VA Reactive .................................................. √((VA) -W ) Full Scale Reading ...................................... 999 counts Phase Range ............................................-180 to +180 degrees Resolution ..........................................................1 degree 9 Ranges (°C or °F).................................. -40.0 to +100.0 ° -100 to +250 ° -100 to +500 ° -100 to +1000 ° -100 to + 2500 ° Probe Sensitivity............................ 1 mV/°C and 1 mV/°F Decibel (dB) dBV................................................ dB relative to one volt dBm ...................dB relative to one mW in 50 Ω or 600 Ω dB on .......................................... VDC, VAC, or VAC+DC Accuracy...........................same as VDC, VAC, VAC+DC Accuracy 0.1 Hz to 1 MHz........................................... ±2 degrees 1 MHz to 10 MHz......................................... ±3 degrees 95 Fluke 196C/199C Users Manual Meter DMM Measurements on Meter Inputs Meter Input Frequency Response...................... DC to 10 kHz (-3 dB) The accuracy of all measurements is within ± (% of reading + number of counts) from 18 °C to 28 °C. Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. Input Impedance ................1 MΩ (±1 %)//10 pF (±1.5 pF) General Input Coupling............................................................. DC Max. Input Voltage .............................. 1000 V CAT II 600 V CAT III (For detailed specifications, see “Safety”) Meter Functions Ranging........................................................Auto, Manual Modes .................................................... Normal, Relative DC Common Mode Rejection (CMRR).................. >100 dB AC Common Mode Rejection at 50, 60, or 400 Hz....... >60 dB Ohms (Ω) Ranges.................................500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ Full Scale Reading 500 Ω to 5 MΩ .............................................. 5000 counts 30 MΩ........................................................... 3000 counts Accuracy .............................................. ±(0.6 % +5 counts) Measurement Current ...................0.5 mA to 50 nA, ±20 % decreases with increasing ranges Open Circuit Voltage ................................................... <4 V Continuity (CONT) Beep..........................................................<50 Ω (±30 Ω) Measurement Current .............................. 0.5 mA, ±20 % Detection of shorts of ............................................. ≥1 ms 96 Specifications DMM Measurements on Meter Inputs 9 Diode AC Voltage (VAC) Maximum Voltage Reading ......................................2.8 V Ranges .....500.0 mV, 5.000 V, 50.00 V, 500.0 V, 1100 V Open Circuit Voltage .................................................<4 V Full Scale Reading ....................................... 5000 counts Accuracy ...............................................±(2 % +5 counts) Accuracy 15 Hz to 60 Hz................................. ±(1 % +10 counts) 60 Hz to 1 kHz .............................. ±(2.5 % +15 counts) For higher frequencies the frequency roll off of the Meter input starts affecting accuracy. Measurement Current .............................. 0.5 mA, ±20 % Temperature (TEMP) With Optional Temperature Probe Ranges (°C or °F) ................................. -40.0 to +100.0 ° -100.0 to +250.0 ° -100.0 to +500.0 ° -100 to +1000 ° -100 to + 2500 ° Probe Sensitivity ............................1 mV/°C and 1 mV/°F DC Voltage (VDC) Ranges..... 500.0 mV, 5.000 V, 50.00 V, 500.0 V, 1100 V Full Scale Reading....................................... 5000 counts Accuracy ............................................±(0.5 % +5 counts) Normal Mode DC Rejection.................................. >50 dB AC+DC Voltage (True RMS) Ranges .....500.0 mV, 5.000 V, 50.00 V, 500.0 V, 1100 V Full Scale Reading ....................................... 5000 counts Accuracy DC to 60 Hz ..................................... ±(1 % +10 counts) 60 Hz to 1 kHz .............................. ±(2.5 % +15 counts) For higher frequencies the frequency roll off of the Meter input starts affecting accuracy. All accuracies are valid if the waveform amplitude is larger than 5 % of full scale. Normal Mode AC Rejection at 50 or 60 Hz ±1 % ....>60 dB 97 Fluke 196C/199C Users Manual Amperes (AMP) Source......................................................Input A, Input B With Optional Current Probe or Current Shunt Max. Sample Speed (10 ms/div to 1 min/div) ...... 20 MS/s Ranges............................. same as VDC, VAC, VAC+DC Glitch capture (10 ms/div to 1 min/div) .................... 50 ns Probe Sensitivity .................100 µV/A, 1 mV/A, 10 mV/A, 100 mV/A, 1 V/A, 10 V/A, and 100 V/A Time/Div in normal mode ...............10 ms/div to 2 min/div Accuracy .......................... same as VDC, VAC, VAC+DC (add current probe or current shunt accuracy) Recorded Time Span ............................. 11 s to 30 hours Recorder TrendPlot (Meter or Scope) Chart recorder that plots a graph of min and max values of Meter or Scope measurements over time. Measurement Speed.................... > 2.5 measurements/s Time/Div......................................... 10 s/div to 20 min/div Record Size ..................................13500 points per input Recorded Time Span .............................90 min to 8 days Time Reference .....................time from start, time of day Scope Record Records scope waveforms in deep memory while displaying the waveform in Roll mode. 98 Record Size...................................27500 points per input Acquisition Modes ...................................... Single Sweep Continuous Roll External Triggering Time Reference..................... time from start, time of day Specifications Zoom, Replay and Cursors 9 Zoom, Replay and Cursors Miscellaneous Zoom Display Horizontal Magnification Scope Record ............................................. up to 100x TrendPlot........................................................ up to 50x Scope ............................................................... up to 8x View Area ...................................... 144 mm (5.65 inches) Replay Displays a maximum of 100 captured dual input Scope screens. Replay modes ...........Step by Step, Replay as Animation Cursor Measurements Cursor Modes.................................. single vertical cursor dual vertical cursors dual horizontal cursors (Scope mode) Markers ...................... automatic markers at cross points Measurements ....................................... value at cursor 1 value at cursor 2 difference between values at cursor 1 and 2 time between cursors Time of Day (Recorder modes) Time from Start (Recorder modes) Rise Time Backlight.....................Cold Cathode Fluorescent (CCFL) Temperature compensated 2 Brightness .............................. Power Adapter: 60 cd / m 2 Batteries: 35 cd / m Power Rechargeable NiMH Batteries: Operating Time.................................................. 4 hours Charging Time ................................................... 4 hours Allowable ambient temperature during charging: .... 0 to 40 °C (32 to 104 °F) Auto power down time (battery saving): ............. 5 min, 30 min or disabled Battery Charger / Power Adapter BC190: • BC190/801 European line plug 230 V ±10 % • BC190/803 North American line plug 120 V ±10 % • BC190/804 United Kingdom line plug 230 V ±10 % • BC190/806 Japanese line plug 100 V ±10 % • BC190/807 Australian line plug 230 V ±10 % • BC190/808 Universal switchable adapter 115 V ±10 % or 230 V ±10 %, with plug EN60320-2.2G Line Frequency........................................... 50 and 60 Hz 99 Fluke 196C/199C Users Manual Probe Calibration Optical InterfacePort Manual pulse adjustment and automatic DC adjustment with probe check. Type .........................................RS-232, optically isolated Generator Output ...................................... 3 Vpp / 500 Hz square wave Memory Number of Scope Memories .........................................10 Each memory can contain two waveforms plus corresponding setups Number of Recorder Memories.......................................2 Each memory can contain: • a dual input TrendPlot (2 x 13500 points per input) • a dual input Scope Record (2 x 27500 points per input) • 100 dual input Scope screens Mechanical Size ........................64 x 169 x 254 mm (2.5 x 6.6 x 10 in) Weight.....................................................1.95 kg (4.3 lbs) including battery 100 To Printer............................. supports Epson FX, LQ, and ® ® HP Deskjet , Laserjet , and Postscript • Serial via PM9080 (optically isolated RS-232 Adapter/ Cable, optional). • Parallel via PAC91 (optically isolated Print Adapter Cable, optional). To PC/Notebook • Serial via PM9080 (optically isolated RS-232 Adapter/ ® Cable, optional), using SW90W (FlukeView software ®, ® ® ® ® for Windows 95 98 , Me , 2000 and NT4 ). Specifications Environmental Environmental Environmental .........................MIL-PRF-28800F, Class 2 Temperature Operating: battery only.......................... 0 to 50 °C (32 to 122 °F) power adapter...................... 0 to 40 °C (32 to 104 °F) Storage............................. -20 to +60 °C (-4 to +140 °F) 9 Electromagnetic Compatibility (EMC) Emission and immunitiy............ EN-IEC61326-1 (1997) Enclosure Protection .............................IP51, ref: IEC529 Humidity Operating: 0 to 10 °C (32 to 50 °F) ...................... noncondensing 10 to 30 °C (50 to 86 °F) ................................... 95 % 30 to 40 °C (86 to 104 °F) .................................. 75 % 40 to 50 °C (104 to 122 °F) ................................ 45 % Storage: -20 to +60 °C (-4 to +140 °F).............. noncondensing Altitude Operating ......................................... 3 km (10 000 feet) Storage........................................... 12 km (40 000 feet) Vibration (Sinusoidal)..........................................max. 3 g Shock ................................................................max. 30 g 101 Fluke 196C/199C Users Manual Safety Designed for measurements on 1000 V Category II Installations, 600 V Category III Installations, Pollution Degree 2, per: • ANSI/ISA S82.01-1994 • EN61010-1 (1993) (IEC1010-1) • CAN/CSA-C22.2 No.1010.1-92 • UL3111-1 Max. Input Voltages Input A and B directly ............................... 300 V CAT III Input A and B via 10:1 probe................... 1000 V CAT II 600 V CAT III METER/EXT TRIG inputs........................ 1000 V CAT II 600 V CAT III Max. Floating Voltage From any terminal to ground ................... 1000 V CAT II 600 V CAT III Between any terminal.............................. 1000 V CAT II 600 V CAT III Voltage ratings are given as “working voltage”. They should be read as Vac-rms (50-60 Hz) for AC sinewave applications and as Vdc for DC applications. 102 Figure 51. Max. Input Voltage v.s. Frequency Note Overvoltage Category III refers to distribution level and fixed installation circuits inside a building. Overvoltage Category II refers to local level, which is applicable for appliances and portable equipment. Specifications 10:1 Probe 9 10:1 Probe Safety Max. Input Voltage ............................1000 V CAT II 600 V CAT III Max. Floating Voltage from any terminal to ground.....................1000 V CAT II 600 V CAT III up to 400 Hz Electrical specifications Input Impedance at probe tip 10 MΩ (±2 %)//14 pF (±2 pF) Capacity Adjustment Range........................... 10 to 22 pF Attenuation at DC (1 MΩ input)....................... 10 x (±2 %) Figure 52. Safe Handling: Max. Input Voltage Between Scope References, and Between Scope References and Meter Reference Bandwidth (with FLUKE 199C).....DC to 200 MHz (-3 dB) Environmental Temperature Operating ............................. 0 to 50 °C (32 to 122 °F) Storage ..........................-20 to +60 °C (-4 to +140 °F) Altitude Operating ....................................... 3 km (10 000 feet) Storage ........................................ 12 km (40 000 feet) Humidity Operating at 10 to 30 °C (50 to 86 °F) ............... 95 % 103 Fluke 196C/199C Users Manual MAX. INPUT VOLTAGE (Vrms) 1000 MAX. VOLTAGE FROM PROBE REFERENCE TO GROUND 1000 CAT II CAT III 500 500 200 200 100 100 50 50 20 20 10 10 5 5 2 2 1 0.01 0.02 0.05 0.1 0.2 0.5 1 2 5 10 20 50 100 200 FREQUENCY (MHz) Figure 53. Max. Voltage From Probe Tip to Ground and From Probe Tip to Probe Reference 104 CAT II 1 0.01 0.02 0.05 0.1 0.2 0.5 CAT III 1 2 5 10 20 50 100 200 FREQUENCY (MHz) Figure 54. Safe Handling: Max. Voltage From Probe Reference to Ground Specifications Electromagnetic Immunity 9 Electromagnetic Immunity The Fluke 190 series, including standard accessories, conforms with the EEC directive 89/336 for EMC immunity, as defined by EN-61326-1, with the addition of the following tables. Scope Mode (10 ms/div): Trace disturbance with VPS200 voltage probe shorted Table 1 No visible disturbance Frequency range 10 kHz to 20 MHz Frequency range 20 MHz to 100 MHz Frequency range 100 MHz to 1 GHz E = 3V/m 5 mV/div to 100 V/div 200 mV/div to 100 V/div *) 500 mV/div to 100 V/div (*) With the 20 MHz Bandwidth Filter switched on: no visible disturbance. With the 20 MHz Bandwidth Filter switched off: disturbance is max 2 div. Table 2 Disturbance less than 10% of full scale Frequency range 20 MHz to 100 MHz E = 3V/m 10 mV/div to 100 mV/div Test Tool ranges not specified in tables 1 and 2 may have a disturbance of more than 10% of full scale. Meter Mode (Vdc, Vac, Vac+dc, Ohm and Continuity): Reading disturbance with test leads shorted Table 3 Disturbance less than 1% of full scale Frequency range 10 kHz to 1 GHz E = 3V/m 500mV to 1000V , 500Ohm to 30 MOhm ranges 105 Fluke 196C/199C Users Manual 106 Index —1— 10-1 Voltage Probe, 83 —2— 2-mm Test Probes, 3, 84 —4— 4-mm Test Probes, 3, 83 —A— A versus B, 20 A*B, 20 A+B, 20 A-B, 20 Accessories, 67, 82 AC-Coupling, 18 Acquiring the Waveform, 18 Altitude, 101, 103 Ampere Measurement, 25 Amperes, 94, 98 Analysis Functions, 37, 99 AS200 Accessory Set, 3, 84 Auto Ranges, 27 Auto Set, 92 Automatic Connect-and-View Trigger, 91 Automatic Power Shutdown, 75 Automatic Scope Measurements, 13 Automatic Triggering, 48 Average, 15 —B— Banana Jack Inputs, 10, 23, 30 Bandwidth, 90, 96 Bargraph, 24 Battery Charger, 3, 83 Charging, 2, 78 Indicator, 78 Life, 75 Refresh, 79 Refresh Date, 82 Replacing, 80 BC190 Battery Charger, 3, 83 —C— C190 Hard Case, 3, 86 C195 Soft Case, 86 Calibrating the Test Tool, 82 Calibrating Voltage Probes, 80, 100 107 Fluke 196C/199C Users Manual Calibration, 100 Capturing 100 Screens, 39, 92 Case, 86 Charge Time, 99 Charger, 83 Charging, 78 Cleaning, 77 Clear Menu, 10, 72 Common Leads, 3 Connect-and-View, 45, 92 Connecting a Computer, 63 Connecting A Printer, 64 Connections, 10, 23 Continuity, 96 Contrast, 73 CS20MA Current Shunt, 86 Current Measurement, 25 Current Probe, 25 Current Shunt, 86 Cursors Measurements, 42 Display, 99 Displaying Recorded Data, 31, 34 DMM Measurements, 24 Documenting Screens, 63 Duty Cycle, 94 —D— FlukeView, 63, 86 Freezing the Readings, 27 Freezing the Screen, 14 Frequency (Hz), 94 Frequency Response, 90, 96 Date, 74 DC Voltage (VDC), 92, 97 Decibel (dB), 95 Delay, Trigger, 91 Deleting Screens, 61 Diode, 97 108 —E— Earth Ground, 6 Edge Trigger, 49, 91 Electrical Shock, 5 Electrically Floating, 6 Electromagnetic Compatibility, 101 Electronic Scope Connections, 68 Emission, 101 Environmental, 101 Environmental Data, 89 External Trigger, 91 External Triggering, 52 —F— —G— Glitch Capture, 17, 34, 35 Ground Leads, 3, 83 Ground Spring, 3, 83 —H— Hard Case, 3, 86 HF Voltage Probe Connection, 68 Hook Clips, 3, 83 Horizontal Cursors, 42 Humidity, 101 Hz, 94 —I— Immunity, 101 Information Language, 73 Input A Measurement, 13 Input B Measurement, 13 Input Coupling, 96 Input Impedance, 90, 96, 103 Input Sensitivity Variable, 19 Interface, 100 Inverted Display, 18 Isolated, 6 —L— Language, 73 Index (continued) —M— Maintenance, 77 Manual, 85 Manual Ranges, 27 Mathematics Functions, 20 Max. Floating Voltage, 102, 103 Max. Input Voltage, 102 Measurement Connections, 10, 23 Measurements, 13, 24 Measurements on Meter Inputs, 96 Mechanical, 100 Memory, 100 Meter Connections, 69 Meter Measurements, 24 Multi Meter Measurements, 24 —N— Navigating a Menu, 9 NiMH Battery, 78 NiMH Battery, 77 Noisy Waveforms, 20, 50 —O— Ohm (Ω), 96 Operating Time, 99 Optical Interface, 63, 64, 100 Oscilloscope, 90 OVERVIEW, 41 —P— PAC91, 64, 86 Parallel Print Cable, 86 Parallel Printer, 64 Parts, 82 Peak, 94 Performance Characteristics, 89 Persistence, 16 Phase, 95 PM9080, 63, 64, 86 Polarity, 18 Power, 99 Power Adapter, 75, 83 Power Down Timer, 75 Powering the Test Tool, 7 Pre Trigger, 47 Print Cable, 86 Probe, 80 Probe Calibration, 80, 100 Pulse Trigger, 55 Pulse Width, 94 Pulse Width Trigger, 92 —R— Readings, 13 Recalibrating, 82 Recalling Screens, 61 Recalling Setups, 62 Record Length, 91 Record+Setup Memory, 60 Recorder, 98 Recorder Options, 32 Recording Waveforms, 33 Refreshing Batteries, 82 Relative Measurements, 28 Replaceable Parts, 82 Replacement Set, 85 Replacing Batteries, 80 Replay, 37, 60, 99 Resetting the Test Tool, 8, 72 Resistance Measurement, 24 Reversing the Polarity, 18 Rise Time, 44, 90 RMS Voltage, 93 Roll Mode Function, 98 RS200 Replacement Set, 85 RS-232 Adapter/Cable, 3, 63, 64, 86 —S— Safety, 102 Safety Characteristics, 89 Safety Requirements, 1 Sampling Rate, 90 109 Fluke 196C/199C Users Manual Saving, 60 SCC 190, 64, 86 Scope, 90 Scope Connections, 11, 68 Scope Cursor Measurements, 99 Scope Measurements, 13 Scope Record, 98 Scope Record, 33 Screen Contrast, 73 Screen Without Menus, 10, 72 Serial Printer, 64 Service Manual, 86 Shock, 101 Single Shot, 50 Single Sweep Mode, 34 Slope, 46, 91 Slow Variations, 30 Smooth, 15 Soft Case, 86 Software, 3, 86 Software Version, 82 Specifications, 89 Spike Capture, 17 Stand, 72 110 Storing, 77 SW90W Software, 3, 64, 86 —T— Temperature, 95, 97, 101, 103 Test Leads, 3 Test Probes, 3, 83 Tilt Stand, 72 Time, 74 Time Base Accuracy, 91 TL24 Test Leads, 84 TrendPlot (Meter), 98 TrendPlot™ Function, 30 Trigger Delay, 47, 91 Level, 46 Modes, 91 Pre-trigger, 47 Trigger Sensitivity, 91 Triggering Automatic, 48, 91 External, 52 On Edges, 49 On Pulses, 55 On Video, 53 On Waveforms, 45 Troubleshooting, 87 TV Triggering, 53 —U— Unpacking, 2 Users Manual, 3, 85 —V— Vertical Accuracy, 90 Vertical Cursors, 43 Vibration, 101 Video Frames, 54 Video Lines, 54 Video Trigger, 53, 91 Viewing Stored Screens, 63 Voltage Probes, 3, 80, 83 VP200 Voltage Probe, 83 VP200 Voltage Probe Set, 3 —Z— Zoom, 40, 99
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2001:09:04 11:39:49 Producer : Acrobat Distiller 4.0 for Windows Creator : AdobePS5.dll Version 5.0.1 Title : Microsoft Word - 0MASTER.DOC Modify Date : 2001:09:28 09:20:40+02:00 Page Count : 118 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools