Fluke Lvd2 Volt Light Users Manual

2015-09-09

: Fluke Fluke-Lvd2-Volt-Light-Users-Manual-810138 fluke-lvd2-volt-light-users-manual-810138 fluke pdf

Open the PDF directly: View PDF PDF.
Page Count: 3

DownloadFluke Fluke-Lvd2-Volt-Light-Users-Manual-  Fluke-lvd2-volt-light-users-manual
Open PDF In BrowserView PDF
FOR USE BY COMPETENT
PERSONS

Anyone using this instrument should be
knowledgeable and trained about the risks
involved with measuring voltage, especially
in an industrial setting, and the importance of
taking safety precautions and of testing the
instrument before and after using it to ensure
that it is in good working condition.

LVD2EU

VoltAlert

Safety Sheet

Read First: Safety Information
WX Warning
To prevent possible electric shock, fire, or personal injury:
●● Use the Product only as specified, or the protection supplied by the Product
can be compromised.
●● Do not use if the flashlight does not operate.
●● The battery door must be closed and locked before you operate the Product.
●● Measure a known voltage first to make sure that the Product operates
correctly.
●● When using the Product if tip does not glow, voltage could still be present.
The Product indicates active voltage in the presence of electrostatic fields
of sufficient strength generated from the source (MAINS) voltage. If the field
strength is low, the Product may not provide indication of live voltages. Lack
of an indication occurs if the Product is unable to sense the presence of
voltage which may be influenced by several factors including, but not limited
to:
•	 Shielded wire/cables
•	 Thickness and type of insulation
•	 Distance from the voltage source
•	 Fully-isolated users that prevent an effective ground
•	 Receptacles in recessed sockets/ differences in socket design
•	 Condition of the Product and Batteries
●● Disable the Product if it is damaged.
●● Do not use the Product if it is damaged.
●● Use Product with arrow visible.
●● Hold the Product behind the tactile barrier.
●● Do not touch voltages > 30 V ac rms, 42 V ac peak, or 60 V dc.
●● Do not use for dc voltage measurements or around voltages exceeding
600 volts, or in the presence of variable motor drives.
●● Use caution with voltages above 30 V ac as a shock hazard may exist.
●● Do not allow the Product to directly touch live circuits.
●● Using the Product while attached to any metal object could lead to electric
shock or personal injury.
●● Do not stare or look directly at the LED flash light. The light is extremely
bright.
●● Comply with local and national safety codes. Use personal protective
equipment (approved rubber gloves, face protection, and flame-resistant
clothes) to prevent shock and arc blast injury where hazardous live
conductors are exposed.
●● Batteries contain hazardous chemicals that can cause burns or explode. If
exposure to chemicals occurs, clean with water and get medical aid.
●● Remove the batteries if the Product is not used for an extended period of time,
or if stored in temperatures above 50 °C. If the batteries are not removed,
battery leakage can damage the Product.
●● Do not disassemble or crush battery cells and battery packs.
PN 4572337 September 2014
© 2014 Fluke Corporation. Specifications are subject to change without notice.
All rights reserved.

●● Do not keep cells or batteries in a container where the terminals can be
shorted.
●● Do not put battery cells and battery packs near heat or fire. Do not put in
sunlight.
●● Carefully read all instructions.
●● Read all safety information before you use the Product.
●● Use this Product indoors only.
●● Use only specified replacement parts.
●● Have an approved technician repair the Product.
For safe operation and maintenance of the product:
●● Be sure that the battery polarity is correct to prevent battery leakage.
●● Repair the Product before use if the battery leaks.

Symbols
T

Double Insulated.

X

Hazardous Voltage. Risk of electric shock.

W

Risk of danger. Important information.



Conforms to European Union directives



Conforms to relevant Canadian and US Standards.



Conforms to relevant Australian standards.



CAT IV

This product complies with the WEEE Directive (2002/96/EC) marking
requirements. The affixed label indicates that you must not discard this
electrical/electronic product in domestic household waste. Product Category:
With reference to the equipment types in the WEEE Directive Annex I, this
product is classed as category 9 “Monitoring and Control Instrumentation”
product. Do not dispose of this product as unsorted municipal waste. Go to
Fluke’s website for recycling information.
Measurement Category IV is applicable to test and measuring circuits
connected at the source of the building’s low-voltage MAINS installation.
Inspected and licensed by TÜV Product Services

Safety Specifications
Altitude.....................................2000 m
Humidity...................................Not rated
Electrical supply......................1.5 Vdc (1 x LR3 ‘AAA’ Battery)
Temperature.............................0 °C to 50 °C
Measurement...........................Category IV (max. 600 V), Pollution Degree 2

Contacting Fluke

●●
●●
●●
●●

Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Anywhere in the world: +1-425-446-5500

Or, visit Fluke’s website at www.fluke.com.
To register your product, visit http://register.fluke.com.
To view, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals.
LIMITED WARRANTY AND LIMITATION OF LIABILITY

This Fluke product will be free from defects in material and workmanship for two years from
the date of purchase. This warranty does not cover fuses, disposable batteries, or damage
from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation
or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To
obtain service during the warranty period, contact your nearest Fluke authorized service center
to obtain return authorization information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS
FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do
not allow the exclusion or limitation of an implied warranty or of incidental or consequential
damages, this limitation of liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090 U.S.A.

11/99

Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Instance ID                     : uuid:f83c95a6-cb7f-42f0-a0c4-54ec419a8701
Original Document ID            : adobe:docid:indd:2114116a-f5fd-11dc-8484-b090b3759c6f
Document ID                     : xmp.id:20b552c2-27db-a94f-b554-ee6bc712caa1
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:C48737189333E4119559B5974AEB244B
Derived From Document ID        : adobe:docid:indd:2114116a-f5fd-11dc-8484-b090b3759c6f
Derived From Original Document ID: adobe:docid:indd:2114116a-f5fd-11dc-8484-b090b3759c6f
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Windows)
History Changed                 : /
History When                    : 2014:09:04 08:53:14-07:00
Create Date                     : 2014:09:04 08:53:14-07:00
Modify Date                     : 2014:09:04 10:08:43-07:00
Metadata Date                   : 2014:09:04 10:08:43-07:00
Creator Tool                    : Adobe InDesign CC 2014 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Layout                     : SinglePage
Page Count                      : 3
Creator                         : Adobe InDesign CC 2014 (Windows)
EXIF Metadata provided by EXIF.tools