Fluke Lvd2 Volt Light Users Manual

2015-09-09

: Fluke Fluke-Lvd2-Volt-Light-Users-Manual-810138 fluke-lvd2-volt-light-users-manual-810138 fluke pdf

Open the PDF directly: View PDF PDF.
Page Count: 3

LVD2EU
VoltAlert
Safety Sheet
Read First: Safety Information
WX Warning
To prevent possible electric shock, re, or personal injury:
Use the Product only as specied, or the protection supplied by the Product
can be compromised.
Do not use if the ashlight does not operate.
The battery door must be closed and locked before you operate the Product.
Measure a known voltage rst to make sure that the Product operates
correctly.
When using the Product if tip does not glow, voltage could still be present.
The Product indicates active voltage in the presence of electrostatic elds
of sufcient strength generated from the source (MAINS) voltage. If the eld
strength is low, the Product may not provide indication of live voltages. Lack
of an indication occurs if the Product is unable to sense the presence of
voltage which may be inuenced by several factors including, but not limited
to:
Shielded wire/cables
Thickness and type of insulation
Distance from the voltage source
Fully-isolated users that prevent an effective ground
Receptacles in recessed sockets/ differences in socket design
Condition of the Product and Batteries
Disable the Product if it is damaged.
Do not use the Product if it is damaged.
Use Product with arrow visible.
Hold the Product behind the tactile barrier.
Do not touch voltages > 30 V ac rms, 42 V ac peak, or 60 V dc.
Do not use for dc voltage measurements or around voltages exceeding
600 volts, or in the presence of variable motor drives.
Use caution with voltages above 30 V ac as a shock hazard may exist.
Do not allow the Product to directly touch live circuits.
Using the Product while attached to any metal object could lead to electric
shock or personal injury.
Do not stare or look directly at the LED ash light. The light is extremely
bright.
Comply with local and national safety codes. Use personal protective
equipment (approved rubber gloves, face protection, and ame-resistant
clothes) to prevent shock and arc blast injury where hazardous live
conductors are exposed.
Batteries contain hazardous chemicals that can cause burns or explode. If
exposure to chemicals occurs, clean with water and get medical aid.
Remove the batteries if the Product is not used for an extended period of time,
or if stored in temperatures above 50 °C. If the batteries are not removed,
battery leakage can damage the Product.
Do not disassemble or crush battery cells and battery packs.
PN 4572337 September 2014
© 2014 Fluke Corporation. Specications are subject to change without notice.
All rights reserved.
FOR USE BY COMPETENT
PERSONS
Anyone using this instrument should be
knowledgeable and trained about the risks
involved with measuring voltage, especially
in an industrial setting, and the importance of
taking safety precautions and of testing the
instrument before and after using it to ensure
that it is in good working condition.
Do not keep cells or batteries in a container where the terminals can be
shorted.
Do not put battery cells and battery packs near heat or re. Do not put in
sunlight.
Carefully read all instructions.
Read all safety information before you use the Product.
Use this Product indoors only.
Use only specied replacement parts.
Have an approved technician repair the Product.
For safe operation and maintenance of the product:
Be sure that the battery polarity is correct to prevent battery leakage.
Repair the Product before use if the battery leaks.
Symbols
TDouble Insulated.
XHazardous Voltage. Risk of electric shock.
WRisk of danger. Important information.
Conforms to European Union directives
Conforms to relevant Canadian and US Standards.
Conforms to relevant Australian standards.
This product complies with the WEEE Directive (2002/96/EC) marking
requirements. The afxed label indicates that you must not discard this
electrical/electronic product in domestic household waste. Product Category:
With reference to the equipment types in the WEEE Directive Annex I, this
product is classed as category 9 “Monitoring and Control Instrumentation”
product. Do not dispose of this product as unsorted municipal waste. Go to
Fluke’s website for recycling information.
CAT IV Measurement Category IV is applicable to test and measuring circuits
connected at the source of the building’s low-voltage MAINS installation.
Inspected and licensed by TÜV Product Services
Safety Specications
Altitude ....................................2000 m
Humidity ..................................Not rated
Electrical supply .....................1.5 Vdc (1 x LR3 ‘AAA Battery)
Temperature ............................0 °C to 50 °C
Measurement ..........................Category IV (max. 600 V), Pollution Degree 2
Contacting Fluke
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Anywhere in the world: +1-425-446-5500
Or, visit Fluke’s website at www.uke.com.
To register your product, visit http://register.uke.com.
To view, print, or download the latest manual supplement, visit
http://us.uke.com/usen/support/manuals.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for two years from
the date of purchase. This warranty does not cover fuses, disposable batteries, or damage
from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation
or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To
obtain service during the warranty period, contact your nearest Fluke authorized service center
to obtain return authorization information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS
FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do
not allow the exclusion or limitation of an implied warranty or of incidental or consequential
damages, this limitation of liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090 U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99