Food Automation Service Techniques XWIRE-SENSOR Food quality & supply chain monitor User Manual Letter Size
Food Automation - Service Techniques, Inc. Food quality & supply chain monitor Letter Size
User manual
Direct, Inc. www.MySCK.com Installation Guide Wireless SmartSensor Device TM "...because you can't improve what you don't measure" ( These instructions should be saved for future reference. ) SmartSensor Direct, Inc. TM NOTICES BEFORE YOU INSTALL SCK Direct, Inc. is not liable for any use of product not in accordance with SCK Direct, Inc.’s installation and operation instructions. SmartSensors should be installed after the installation of your SCK Smart Direct 2TM, SCK Kitchen AdvisorTM, or (FAST.) XwireTM Wireless Gateway. LOCATE YOUR MAC ID Fill in the included form with your MAC ID numbers. The MAC ID numbers are located on the back of the SmartSensors. CLEANING Using a clean damp cloth, wipe down the SmartSensor when necessary using a commercial quality foodservice-approved detergent. DO NOT IMMERSE. Before starting the installation, please fax the sheet immediately to the SCK Helpdesk at +1 203-377-8187. This is necessary for proper network setup by SCK Direct, Inc. NEVER use chemical or abrasive cleaners on the SmartSensor. TOOLS REQUIRED FOR INSTALLATION Drill Bit: 3/16” if using wall anchor, or #50 if installing into Phillips Screwdriver metal INCLUDED PARTS Please confirm that these parts have shipped with your order: 231-60232-01 SmartSensor 229-51362 Installation Manual 139-10029 Magnet SmartSensor Mounting Kit 213-50641 Magnet Mounting Kit 213-50758-01 229-51364 MAC ID Identification Fax Sheet If something is missing, please call 1-866-840-4271 (8:00 a.m. 5:00 p.m. EST). Changes or modifications not expressly approved by SCK Direct, Inc. could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving Increase the separation between the equipment and antenna. Connect the equipment into an outlet on a circuit different receiver. Consult the dealer or an experienced radio/TV technician for from that to which the receiver is connected. help. INSTALLATION WITHOUT DOOR OPEN/CLOSE FEATURE 1a. Choose a location for the SmartSensor to be installed. Use the SmartSensor mounting bracket as a template and mark the locations of the 2 mounting holes. View the tentative positioning and ensure that there are no location problems. Drill the 2 holes with the appropriate drill bit as defined in Tools Required. Insert screws and mount bracket. © 2007-2008 SCK Direct, Inc. 229-51262 Rev B www.MySCK.com installation guide 1b. If holes cannot be drilled, use supplied Velcro. Before mounting, clean surface with an alcohol pad. Adhere one side of Velcro to the mounting surface and one side of Velcro to the back side of bracket. 2. With the SmartSensor located within 10 feet of your SCK Smart Direct 2, SCK Kitchen Advisor, or (FAST.) XwireTM Wireless Gateway, wave the supplied magnet across the embossed rectangle located on the bottom of the SmartSensor at a maximum distance of .25” (6.35 mm). Confirm the SmartSensor wakes up. You should see an LED inside the SmartSensor flash for 10 seconds before turning off. STORE MAGNET FOR FUTURE USE. NOTE: If the SmartSensor does not wake up, bring it close to the SCK Smart Direct 2 so you can see the signal strength indicator on the front. Wave magnet across the SmartSensor again. If the SCK Smart Direct 2 lights flash, the SmartSensor is already activated. 3a. Clip the SmartSensor into its bracket. 3b. Adhere SmartSensor assembly to mounting surface and ensure it is secure. INSTALLING THE MAGNET 4. On the bottom side of the SmartSensor there is an embossed rectangle. Line the magnet up with the rectangle. NOTE: If the SmartSensor does not wake up, bring it close to the SCK Smart Direct 2 so you can see the signal strength indicator on the front. Wave magnet across the SmartSensor again. If the SCK Smart Direct 2 lights flash, the SmartSensor is already activated. EMBOSSED RECTANGLE 3a. Clip the SmartSensor into its bracket. 3b. Adhere SmartSensor assembly to mounting surface and ensure it is secure. 4. Your SmartSensor(s) will now be activated. Call the SCK Helpdesk at 1-866-840-4271 (8:00 a.m. to 5:00 p.m. EST) to confirm Sensors are on the network. 5a. Using the open end of this instruction manual as a gauge, place the manual between the bottom of the SmartSensor and the top of the magnet being sure to keep the magnet aligned with the embossed rectangle. NOTE: The maximum space allowed between the SmartSensor and top of magnet is 0.25” (6.35 mm). Use the magnet as a template and mark the locations of the 2 mounting holes. View the tentative positioning and ensure there are no location problems. Drill the 2 holes with the appropriate drill bit as defined in Tools Required. Insert screws and mount magnet. INSTALLATION WITH DOOR OPEN/CLOSE FEATURE INSTALLING THE SmartSensor 1a. The SmartSensor should be installed in the center of the door opening at the top of the door frame. Use the SmartSensor mounting bracket as a template and mark the locations of the 2 mounting holes. Be sure to leave enough room for the door to close. View the tentative positioning and ensure there are no location problems. Drill the 2 holes with the appropriate drill bit as defined in Tools Required. Insert screws and mount bracket. 1b. If holes cannot be drilled, use supplied Velcro. Before mounting, clean surface with an alcohol pad. Adhere one side of Velcro to the mounting surface and one side of Velcro to the back side of bracket. 2. With the SmartSensor located within 10 feet of your SCK Smart Direct 2, SCK Kitchen Advisor, or (FAST.) XwireTM Wireless Gateway, wave the supplied magnet across the embossed rectangle located on the bottom of the SmartSensor at a maximum distance of .25” (6.35 mm). Confirm the SmartSensor wakes up. You should see an LED inside the SmartSensor flash for 10 seconds before turning off. STORE MAGNET FOR FUTURE USE. © 2007-2008 SCK Direct, Inc. 5b. If holes cannot be drilled, use supplied Velcro. Before mounting, clean surface with an alcohol pad. Adhere one side of Velcro to the mounting surface and one side of Velcro to the magnet. 6. Your SmartSensor will now be activated. Call the SCK Helpdesk at 1-866-840-4271 (8:00 a.m. to 5:00 p.m. EST) to confirm Sensors are on the network. 229-51262 Rev B www.MySCK.com Troubleshooting Should you experience problems installing your SCK SmartSensors, or any aspect of your SCK Direct, Inc. services, please contact the SCK HelpDesk tollfree at 1.866.840.4271 (Monday-Friday, 8:00 a.m.-5:00 p.m. EST). Optional SCK System Components SCK has a variety of optional accessories to help you complete your kitchen automation: SCK Kitchen Advisor Information Server SCK Remote Input Device SCK KMS Kitchen Status Monitor SCK-Enabled Appliance Controllers SCK Wireless (XwireTM) Appliance Interface SCK Wireless (XwireTM) Temperature/Door SmartSensorTM SCK Wireless (XwireTM) Wireless.Gateway SCK Wired Backbone For additional information on any of these accessories, or to request Technical Specification Sheets, please contact your SCK Representative or contact SCK Customer Support toll-free at 1-866-840-4271 (Monday-Friday, 8:00 a.m. to 5:00 p.m. EST). Thank You for Choosing SCK Direct, Inc! SCK Direct, Inc. 905 Honeyspot Road Stratford, CT 06615 +1 203.377.4174 voice +1 203.377.8187 fax 1.866.840.4271 toll-free sales & helpdesk www.MySCK.com; info@mysck.com 229-51362 Rev. B © 2007-2008 SCK Direct, Inc. Printed in the USA 23JAN2008 Direct, Inc. This document contains confidential information. The dissemination, publication, copying, or duplication of this document or the software described herein without prior wirtten authorization is strictly prohibited. XwireTM is a product of Food Automation Service Techniques, Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 4 Create Date : 2008:01:23 12:10:48 Creator : QuarkXPress(R) 7.3 Producer : QuarkXPress(R) 7.3 Modify Date : 2008:01:23 12:10:48 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments Title : Letter SizeEXIF Metadata provided by EXIF.tools