Food Automation Service Techniques XWIRE-SENSOR Food quality & supply chain monitor User Manual Letter Size

Food Automation - Service Techniques, Inc. Food quality & supply chain monitor Letter Size

User manual

Download: Food Automation Service Techniques XWIRE-SENSOR Food quality & supply chain monitor User Manual Letter Size
Mirror Download [FCC.gov]Food Automation Service Techniques XWIRE-SENSOR Food quality & supply chain monitor User Manual Letter Size
Document ID1581398
Application IDsr9MfGh7ZPJhTD5Fxh34wg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize22.33kB (279172 bits)
Date Submitted2011-11-15 00:00:00
Date Available2012-05-10 00:00:00
Creation Date2008-01-23 12:10:48
Producing SoftwareQuarkXPress(R) 7.3
Document Lastmod2008-01-23 12:10:48
Document TitleLetter Size
Document CreatorQuarkXPress(R) 7.3

Direct, Inc.
www.MySCK.com
Installation Guide
Wireless SmartSensor Device
TM
"...because you can't improve
what you don't measure"
( These instructions should be saved for future reference. )
SmartSensor
Direct, Inc.
TM
NOTICES
BEFORE YOU INSTALL
SCK Direct, Inc. is not liable for any use of product not in accordance with SCK Direct, Inc.’s installation and operation
instructions.
SmartSensors should be installed after the installation of your
SCK Smart Direct 2TM, SCK Kitchen AdvisorTM, or (FAST.) XwireTM
Wireless Gateway.
LOCATE YOUR MAC ID
Fill in the included form with your MAC ID numbers. The MAC ID
numbers are located on the back of the SmartSensors.
CLEANING
Using a clean damp cloth, wipe down the SmartSensor when
necessary using a commercial quality foodservice-approved
detergent. DO NOT IMMERSE.
Before starting the installation, please fax the sheet immediately
to the SCK Helpdesk at +1 203-377-8187. This is necessary for
proper network setup by SCK Direct, Inc.
NEVER use chemical or abrasive cleaners on the SmartSensor.
TOOLS REQUIRED FOR INSTALLATION
 Drill Bit: 3/16” if using wall anchor, or #50 if installing into
 Phillips Screwdriver
metal
INCLUDED PARTS
Please confirm that these parts have shipped with your order:
231-60232-01 SmartSensor
229-51362 Installation Manual
139-10029 Magnet
SmartSensor Mounting Kit
213-50641
Magnet Mounting Kit
213-50758-01
229-51364 MAC ID Identification
Fax Sheet
If something is missing, please call 1-866-840-4271 (8:00 a.m. 5:00 p.m. EST).
Changes or modifications not expressly
approved by SCK Direct, Inc. could void the
user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one
or more of the following measures:
 Reorient or relocate the receiving
 Increase the separation between the equipment and
antenna.
 Connect the equipment into an outlet on a circuit different
receiver.
 Consult the dealer or an experienced radio/TV technician for
from that to which the receiver is connected.
help.
INSTALLATION WITHOUT
DOOR OPEN/CLOSE FEATURE
1a. Choose a location for the SmartSensor to be installed. Use
the SmartSensor mounting bracket as a template and mark
the locations of the 2 mounting holes.
View the tentative positioning and ensure that there are no
location problems. Drill the 2 holes with the appropriate drill
bit as defined in Tools Required. Insert screws and mount
bracket.
© 2007-2008 SCK Direct, Inc.
229-51262 Rev B
www.MySCK.com
installation guide
1b. If holes cannot be drilled, use supplied Velcro. Before
mounting, clean surface with an alcohol pad. Adhere one
side of Velcro to the mounting surface and one side of
Velcro to the back side of bracket.
2.
With the SmartSensor located within 10 feet of your SCK
Smart Direct 2, SCK Kitchen Advisor, or (FAST.) XwireTM
Wireless Gateway, wave the supplied magnet across the
embossed rectangle located on the bottom of the
SmartSensor at a maximum distance of .25” (6.35 mm).
Confirm the SmartSensor wakes up. You should see an LED
inside the SmartSensor flash for 10 seconds before turning
off. STORE MAGNET FOR FUTURE USE.
NOTE: If the SmartSensor does not wake up, bring it close to
the SCK Smart Direct 2 so you can see the signal strength
indicator on the front. Wave magnet across the SmartSensor
again. If the SCK Smart Direct 2 lights flash, the SmartSensor
is already activated.
3a. Clip the SmartSensor into its bracket.
3b. Adhere SmartSensor assembly to mounting surface and
ensure it is secure.
INSTALLING THE MAGNET
4. On the bottom side of the SmartSensor there is an
embossed rectangle. Line the magnet up with the rectangle.
NOTE: If the SmartSensor does not wake up, bring it close to
the SCK Smart Direct 2 so you can see the signal strength
indicator on the front. Wave magnet across the SmartSensor
again. If the SCK Smart Direct 2 lights flash, the SmartSensor
is already activated.
EMBOSSED
RECTANGLE
3a. Clip the SmartSensor into its bracket.
3b. Adhere SmartSensor assembly to mounting surface and
ensure it is secure.
4.
Your SmartSensor(s) will now be activated. Call the SCK
Helpdesk at 1-866-840-4271 (8:00 a.m. to 5:00 p.m. EST) to
confirm Sensors are on the network.
5a. Using the open end of this instruction manual as a gauge,
place the manual between the bottom of the SmartSensor
and the top of the magnet being sure to keep the magnet
aligned with the embossed rectangle. NOTE: The maximum
space allowed between the SmartSensor and top of
magnet is 0.25” (6.35 mm).
Use the magnet as a template and mark the locations of the
2 mounting holes. View the tentative positioning and
ensure there are no location problems. Drill the 2 holes with
the appropriate drill bit as defined in Tools Required. Insert
screws and mount magnet.
INSTALLATION WITH
DOOR OPEN/CLOSE FEATURE
INSTALLING THE SmartSensor
1a. The SmartSensor should be installed in the center of the
door opening at the top of the door frame. Use the
SmartSensor mounting bracket as a template and mark the
locations of the 2 mounting holes. Be sure to leave enough
room for the door to close.
View the tentative positioning and ensure there are no location problems. Drill the 2 holes with the appropriate drill bit
as defined in Tools Required. Insert screws and mount
bracket.
1b. If holes cannot be drilled, use supplied Velcro. Before
mounting, clean surface with an alcohol pad. Adhere one
side of Velcro to the mounting surface and one side of
Velcro to the back side of bracket.
2.
With the SmartSensor located within 10 feet of your SCK
Smart Direct 2, SCK Kitchen Advisor, or (FAST.) XwireTM
Wireless Gateway, wave the supplied magnet across the
embossed rectangle located on the bottom of the
SmartSensor at a maximum distance of .25” (6.35 mm).
Confirm the SmartSensor wakes up. You should see an LED
inside the SmartSensor flash for 10 seconds before turning
off. STORE MAGNET FOR FUTURE USE.
© 2007-2008 SCK Direct, Inc.
5b. If holes cannot be drilled, use supplied Velcro. Before
mounting, clean surface with an alcohol pad. Adhere one
side of Velcro to the mounting surface and one side of
Velcro to the magnet.
6.
Your SmartSensor will now be activated. Call the SCK
Helpdesk at 1-866-840-4271 (8:00 a.m. to 5:00 p.m. EST) to
confirm Sensors are on the network.
229-51262 Rev B
www.MySCK.com
Troubleshooting
Should you experience problems installing your SCK SmartSensors, or any
aspect of your SCK Direct, Inc. services, please contact the SCK HelpDesk tollfree at 1.866.840.4271 (Monday-Friday, 8:00 a.m.-5:00 p.m. EST).
Optional SCK System Components
SCK has a variety of optional accessories to help you complete
your kitchen automation:
SCK Kitchen Advisor Information Server
SCK Remote Input Device
SCK KMS Kitchen Status Monitor
SCK-Enabled Appliance Controllers
SCK Wireless (XwireTM) Appliance Interface
SCK Wireless (XwireTM) Temperature/Door SmartSensorTM
SCK Wireless (XwireTM) Wireless.Gateway
SCK Wired Backbone
For additional information on any of these accessories, or to
request Technical Specification Sheets, please contact your SCK
Representative or contact SCK Customer Support toll-free at
1-866-840-4271 (Monday-Friday, 8:00 a.m. to 5:00 p.m. EST).
Thank You for Choosing
SCK Direct, Inc!
SCK Direct, Inc.
905 Honeyspot Road
Stratford, CT 06615
+1 203.377.4174 voice
+1 203.377.8187 fax
1.866.840.4271 toll-free sales & helpdesk
www.MySCK.com; info@mysck.com
229-51362 Rev. B
© 2007-2008 SCK Direct, Inc.
Printed in the USA
23JAN2008
Direct, Inc.
This document contains confidential information. The dissemination, publication, copying, or duplication of this document or
the software described herein without prior wirtten authorization is strictly prohibited.
XwireTM is a product of Food Automation Service Techniques, Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 4
Create Date                     : 2008:01:23 12:10:48
Creator                         : QuarkXPress(R) 7.3
Producer                        : QuarkXPress(R) 7.3
Modify Date                     : 2008:01:23 12:10:48
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Title                           : Letter Size
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UJ7-XWIRE-SENSOR

Navigation menu