Fortinet 220101 FORTIAP-220A User Manual FortiAP 200A QuickStart Guide

Fortinet Inc. FORTIAP-220A FortiAP 200A QuickStart Guide

User Manual

QuickStart Guide© Copyright 2010 Fortinet Incorporated. All rights reserved.  Products mentioned in this document are trademarks or registered trademarks of their respective holders.Regulatory ComplianceFCC Class A Part 15, / CE Mark11 March 2010FortiAP-220A01-430-120928-2010011Visit these links for more information and documentation for your Fortinet product:Technical Documentation - http://docs.fortinet.com     Fortinet Knowledge Center - http://kb.fortinet.comTechnical Support - http://support.fortinet.com    Training Services - http://campus.training.fortinet.comIf the FortiGate wireless controller IP address cannot be determined from the methods above or if the network uses static IP addresses, do the following:1.  Connect the FortiAP to a separate private switch or hub or directly connect to your computer via a cross-over cable. 2.  Telnet to IP address 192.168.1.23.  Login with username: root and no password.4.  Type the following command to enter static IP address for Access Point <enter command here>5.  Type the following command to enter the static IP address of Forti-Gate Wireless Controller <enter command here>6.  Exit from command line and move the FortiAP to the intended de-ployment location and connect Ethernet cable as described above.7.  In Web Cong, go to Wireless Controller > Physical AP > Managed Physical AP.  Look for the name or serial number of the newly con-nected unit.  8.  In the Mode eld, select Enable.  9.  Select a FortiAP prole from the list and click OK.10.  The conguration is downloaded from the FortiGate unit to the For-tiAP and the Wireless LED lights up.Note: FortiGate Low encryption units must be matched up with Low Encryption Access Points.Conguring continued...Power Required Adaptor Input 100-240V~ 50/60Hz 0.6AOutput: 12V DC 1.5A –center positiveDimensions 1.1 in (2.7 cm) x 6.4 in (16.3 cm) x 5.1 in (12.9 cm)Ethernet port 1 x 10/100Indoor/outdoor deployment IndoorMount Wall or ceilingFederal Communication Commission Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interfer-ence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the follow-ing measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.FCC Caution: Any changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.For operation within 5.15 ~ 5.25GHz frequency range, it is restricted to indoor environment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.IMPORTANT NOTE: Radiation Exposure StatementThis equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.The availability of some specic channels and/or operational frequency bands are country dependent and are rmware programmed at the factory to match the intended destination. The rmware setting is not accessible by the end user. Industry Canada StatementThis device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Règlement d’Industry Canada Les conditions de fonctionnement sont sujettes à deux conditions:1) Ce périphérique ne doit pas causer d’interférence et.2) Ce périphérique doit accepter toute interférence, y compris les interférences pouvant perturber le bon fonc-tionnement de ce périphérique. IMPORTANT NOTE: Radiation Exposure StatementThis equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equip-ment should be installed and operated with minimum distance 20cm between the radiator & your body. Caution:The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems.
LED DescriptionPackage ContentsPORT 0 PORT 1 PORT 2 PORT 3 PORT 4RESET POWERPort 1 to 4 LEDs Wireless LEDPort 0 LEDPower LEDPorts 0 to 4 Reset buttonPower buttonFrontBackInterface DescriptionConnectingAdministrator loginUsername adminPassword <none>Default port addressesPort 0 192.168.1.2Port 1 Do not usePort 2 Do not usePort 3 Do not usePort 4 Do not useStraight-throughEthernet cableFortiGate-3 0BCopyright 2010 Fortinet Incorporated. All rights reserved.TrademarksProducts mentioned in this document are trademarks.QuickStart GuidePower SupplyREGISTERFactory DefaultsLED State DescriptionPowerGreen The unit is on.Green Flash-ingThe unit is starting up.Off The unit is off.Ethernet Port 0Green The correct cable is in use and Ethernet connectivity is established.Green Flash-ingThe port is sending or receiving data (activity)Off No link.Wireless Green At least one wireless radio is enabled.Off Both wireless radios are disabled.Port 1 to 4Green Port is connected. This condition is not recommended.Off Port is not connected. This is the desired state.Inter-faceType Speed Proto-colDescriptionPORT 0  RJ-45 10/100 Base-TEthernet Use this port as the primary connection to the LANPORT 1 to PORT 4RJ-45 10/100 Base-TEthernet Do not use these ports.Reset buttonHold for 5 seconds to reset the FortiAP unit to its factory defaults.Using the provided template and two M3 screws, attach the unit to the wall or ceiling using the two mounting holes at the bottom of the FortiAP unit. If placing on desktop, attach the rubber feet to the unit. Connect the following to the FortiAP unit:1.  Insert a network cable to Port 0. •  Use straight-through cable for most equipment•  Use cross-over cable if connecting to FortiGate units without auto MDI detect2.  Insert the other end of the network cable into your LAN Ethernet edge switch, or directly to the FortiGate Controller.  3.  Connect the power adaptor to AC outlet.   4.  Insert the power adaptor connector to the FortiAP unit.  Note: The FortiAP-220A does not support 802.3af POE therefore AC power connection is mandatory.  Use only the supplied power adaptor.  Substitution of power adaptor can damage the system and voids your warranty.ConguringThe FortiAP is designed to require no conguration in most networks. Zero Conguration mode works if the FortiAP is directly connected to the FortiGate performing the Wireless LAN Controller (WLC) functions, or on the same layer-2 network and subnet as the FortiGate. To enable the FortiAP using Zero Conguration:1.  Connect the network and power cable as described in the Connect-ing section.2.  Once power is applied, the FortiAP goes through boot procedure and requests an IP address from the DHCP server. 3.  If the IP address is retrieved successfully, the FortiAP enters dis-covery mode to locate a FortiGate wireless controller. The discovery modes are:•  Broadcast •  Multicast•  DHCP option 1384.  If this is the rst time connecting the FortiAP to the controller, only the power light and Port 0 LED is lit. If the FortiAP has been pre-provisioned in the controller, the Wireless LED is also lit.5.  Verify that the FortiAP has successfully connected to the controller. In Web Cong, go to Wireless Controller > Physical AP > Managed Physical AP.  Look for the name or serial number of the newly con-nected unit.  6.  In the Mode eld, select Enable.  7.  Select a FortiAP prole from the list and click OK.8.  The conguration is downloaded from the FortiGate unit to the For-tiAP and the Wireless LED lights up.

Navigation menu