FrSky Electronic W2409R 2.4G Receiver User Manual X8R manual fcc

FrSky Electronic Co., Ltd. 2.4G Receiver X8R manual fcc

User manual

Download: FrSky Electronic W2409R 2.4G Receiver User Manual X8R manual fcc
Mirror Download [FCC.gov]FrSky Electronic W2409R 2.4G Receiver User Manual X8R manual fcc
Document ID1977974
Application IDFrUzkOxJZZY6nG59P/ytLw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize16.14kB (201702 bits)
Date Submitted2013-05-29 00:00:00
Date Available2013-05-29 00:00:00
Creation Date2013-05-14 08:40:05
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2013-05-14 16:57:23
Document TitleMicrosoft Word - X8R_manual_fcc.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: marc

www.frsky‐rc.com
05/02/13
Instruction Manual for FrSky 2.4G Receiver X8R
Introduction
Thank you for purchasing FrSky 2.4G Receiver X8R 8/16ch full duplex telemetry receiver. In order to fully enjoy the
benefits of this system, please read the instruction manual carefully and set up the device as described below.
Overview
Specifications
Dimension: 46.3 x 26.8 x 13.6mm (L x W x H)
Weight: 14g
Number of Channels: 1~8ch from conventional channel outputs, 1~16ch from SBUS port
With RSSI output: analog voltage output (0~3.3V)
Operating Voltage Range: 4.0~10V
Operating Current: 100mA@5V
Operating Range: full range (>1.5km)
Compatibility: FrSky XJT module in D16 mode (Switch 1 is OFF, Switch 2 is OFF) or D8 mode (Switch 1 is ON, Switch 2 is
OFF), DFT/DJT/DHT/DHT‐U in D_mode
Firmware Upgradeable
What’s New!



More number of channels: 1~8ch from conventional channel outputs, 1~16ch from SBUS port
With RSSI output: analog voltage output (0~3.3V)
Smart Port enabled, realizing two‐way full duplex transmission.
Smart Port (S. Port) is a signal wire full duplex digital transmission interface developed by FrSky Electronic
Co., Ltd. All products enabled with Smart Port (including XJT module, X8R receiver, new hub‐less sensors, new Smart
Dashboard, etc), serial port user data and other user input/output devices can be connected without limitations for
numbers or sequences at a high transmission speed.
Binding Procedure
Binding is the process of uniquely associating a particular receiver to a transmitter module. A transmitter module can be
bound to multiple receivers (not to be used simultaneously). A receiver can only be bound to one transmitter module.
2
www.frsky‐rc.com
05/02/13
Follow the steps below to finish the binding procedure.
1. Turn on the transmitter while holding the F/S button on the module (please refer to the module instruction manual for
switch positions). Release the button. The RED LED on the XJT module will flash, indicating the transmitter is ready to bind
to the receiver.
2. Connect the battery to the receiver while holding the F/S button on the receiver. The RED LED on the receiver will flash,
indicating the binding process is completed.
3. Turn off both the transmitter and the receiver.
4. Turn on the transmitter and connect the battery. The RED LED on the receiver indicates the receiver is receiving
commands from the transmitter. The receiver/transmitter module binding will not have to be repeated, unless one of the
two is replaced.
Note: After binding procedure is completed, recycle the power and check if the receiver is really under control by linked
transmitter.
Range Check
A pre‐flight range check should be done before each flying session. Reflections from nearby metal fences, concrete
buildings or trees can cause loss of signal both during range check and during the flight. Follow the steps below to perform
the range check.
1. Place the model at least 60cm (two feet) above non‐metal contaminated ground (e.g. on a wooden bench).
2. The receiver antennas should be separated in the model, and do not touch the ground.
3. The module antenna should be in a vertical position.
4. Turn on the transmitter and the receiver, press the F/S button on the XJT module for 4 seconds to enter range check
mode, the RED LED will be off, GREEN LED will flash rapidly. The effective distance will be decreased to 1/30 (at least 30m).
5. Walk away from the model while simultaneously operating the controls on the transmitter to confirm all controls’
normal operation.
6. Press the F/S button on the XJT module for 1~4 seconds to exit range check mode, RED LED will be back on, indicating
normal operation is back.
Failsafe
Failsafe is a useful feature in which all controls move to a preset position whenever the control signal is lost for a period of
time. 2.4G Receiver X8R supports failsafe function for all channels. Follow the steps below to set failsafe positions for each
channel:
1. Bind the receiver first and turn on both the transmitter and the receiver;
2. Move the controls to the desired failsafe position for all channels;
3. Press briefly the F/S button on the receiver (less than 1 second). The Green LED will flash twice, indicating the failsafe
position has been set in the receiver.
To disable the failsafe function, re‐bind the receiver.
Failsafe is recommended to set when system is firstly used, or receiver has been re‐bound. Follow steps below to set
failsafe.
Option‐1. How to set failsafe to a user‐determined state on lost signal:
1) Bind the receiver to the transmitter module first and turn on both the transmitter and the receiver;
2) Move the controls to desired failsafe position for all channels;
3) Press briefly the F/S button on the receiver and you are done.
Option‐2. How to set failsafe for no pulses on lost signal:
1) Turn off the transmitter, power on the receiver, and then press briefly the F/S button on the receiver.
Note: If failsafe is not set, failsafe default will hold last position before signal is lost. In this case, there exists risk that
your model will fly away or cause injury.
FrSky Electronic Co., Ltd.
Tel: (86) 510‐85187718 Fax: (86) 510‐85187728
E‐mail: frsky@frsky‐rc.com Technical Support: sales4tech@gmail.com
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : marc
Create Date                     : 2013:05:14 08:40:05+08:00
Modify Date                     : 2013:05:14 16:57:23+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2013:05:14 16:57:23+08:00
Format                          : application/pdf
Title                           : Microsoft Word - X8R_manual_fcc.doc
Creator                         : marc
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:a3dc7aac-c927-42f6-8593-d83032c516cb
Instance ID                     : uuid:ab16ac21-b25c-4ee8-b775-6abb4ad8d26a
Page Count                      : 3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XYFW2409R

Navigation menu