Friedrich Luetze 77920X0401 Ethernet Switch User Manual BA LCOS Unmanaged Switch V00 EN

Friedrich Luetze GmbH Ethernet Switch BA LCOS Unmanaged Switch V00 EN

Users Manual

Operating InstructionsLCOS Unmanaged Switch4 ports / 8 ports779200.0401, LCOS-SW-4P779201.0401, LCOS-SW-4P779200.0801, LCOS-SW-8P779201.0801, LCOS-SW-8PVersion 0023.08.2018
Friedrich Lütze GmbHPostfach 1224 (PLZ 71366)Bruckwiesenstrasse 17-19D-71384 Weinstadt GERMANY / DEUTSCHLANDTel.: +49 (0) 7151 6053-0Fax: +49 (0) 7151 6053-277(-288)info@luetze.dewww.luetze.comThe company Friedrich Lütze GmbH reserves the right to make changes to its products in the interest of technical development. These changes are not necessarily documented in each individual case.This manual and the information contained herein have been compiled with due care. However, the company Friedrich Lütze GmbH accepts no liability for printing or other errors or resulting damage.The brands and product names mentioned in this book are trademarks or registered trademarks of the respective titleholders.© Copyright 2018 by Friedrich Lütze GmbH. All rights reserved.
LCOS Unmanaged Switch ▪ Contents1TRANSPORTATION1 Introduction....................................................................................................... 41.1 About these instructions ..............................................................................................................  52 General Information.......................................................................................... 62.1 Safety instructions and technical information ..............................................................................  62.2 Copyright .....................................................................................................................................  62.3 Disclaim of Liability ......................................................................................................................  62.4 Standards and norms ..................................................................................................................  72.5 Scope of validity of the manual....................................................................................................  82.6 Approvals.....................................................................................................................................  92.7 Applicable documents................................................................................................................  113 Safety............................................................................................................... 123.1 Contents of the operating instructions .......................................................................................  123.2 Applicable documents................................................................................................................  123.3 Appropriate Use.........................................................................................................................  123.4 Product life.................................................................................................................................  133.5 Addressees................................................................................................................................  143.6 Responsibility of the operator ....................................................................................................  153.7 Changes and modifications to the devices ................................................................................  153.8 Safety device .............................................................................................................................  153.9 Special safety notes...................................................................................................................  153.10 Further safety notes ..................................................................................................................  174 Product Overview ........................................................................................... 184.1 Construction types .....................................................................................................................  184.2 Overview of product features.....................................................................................................  194.3 Function carrier (with power module) ........................................................................................ 215 Transport and storage.................................................................................... 226 Scope of delivery............................................................................................ 236.1 The LCOS Unmanaged Switch consists of:...............................................................................  236.2 Accessories   .............................................................................................................................  236.3 Checking the delivery ................................................................................................................  247 Product Assembly .......................................................................................... 257.1 LCOS Unmanaged Ethernet-Switches ......................................................................................  257.2 LED status displays ...................................................................................................................  268 Technical Data ................................................................................................ 278.1 Identification...............................................................................................................................  278.2 Description.................................................................................................................................  278.3 Communication..........................................................................................................................  278.4 Safety.........................................................................................................................................  278.5 General ......................................................................................................................................  279 Mounting / Dismounting................................................................................. 299.1 Installation position ....................................................................................................................  299.2 Mounting ....................................................................................................................................  309.3 Wiring.........................................................................................................................................  369.4 Pin assignment ..........................................................................................................................  379.5 Further information on the LCOS system (basics).....................................................................  389.6 Coding of LCOS modules ..........................................................................................................  399.7 Installing Data and Power Bridges.............................................................................................  4010 Commissioning - Hardware  .......................................................................... 4110.1 Safety notes Power supply       ..................................................................................................  4110.2 Safety notes Housing.................................................................................................................  42
LCOS Unmanaged Switch ▪ Contents2TRANSPORTATION11 Operation......................................................................................................... 4311.1 Functional description................................................................................................................  4311.2 Frame-Switching functionalities .................................................................................................  4311.3 Specific functions of the Ethernet interface ............................................................................... 4411.4 Other functions and features .....................................................................................................  4411.5 Display elements .......................................................................................................................  4411.6 Interfaces ...................................................................................................................................  4512 Maintenance - Hardware ................................................................................ 4613 Final Shutdown and Disposal........................................................................ 4714 Service............................................................................................................. 4815 Appendix ......................................................................................................... 4915.1 Overview of other applicable documents...................................................................................  4915.2 Explanation of abbreviations used.............................................................................................  5016 Revision history.............................................................................................. 52
LCOS Unmanaged Switch ▪ Introduction4TRANSPORTATION1 IntroductionThese operating instructions are part of the LCOS Unmanaged Switch. Before using the device, please read these operating instructions to avoid possible dangers and to ensure proper use.    Short description LCOS Unmanaged (Industrial Ethernet) SwitchesThe LCOS unmanaged switches are highly suitable for use in industrial ethernet networks. In addition to durability, the units also offer more performance, such as QoS (Quality of services) or operation in Profinet and Ethernet IP. Thanks to their modular design, the units can be supplied with power in the LCOS system either by means of the existing connectors or via the energy bus. They can also be used in building automation systems due to the fact that they can run on AC voltage. The application temperature range is -25 °C to +70°C. Read and understand these instructions before installing, operating, or maintaining the equipment.Risk of injury and damage to property due to non-observance of the operating instructions. Always read these operating instructions before planning the system in order to avoid or reduce risks and damage. These operating instructions contain important information on safety, commissioning, operation, maintenance and disposal of the device.Always keep the document at hand. This applies until the device is disposed of. Pass on the operating instructions if the device is sold, distributed or loaned.You can also find these operating instructions at www.luetze.com.In the search field, enter either the product name: LCOS Unmanaged Switch or the product number: 77920*
LCOS Unmanaged Switch ▪ Introduction5TRANSPORTATION1.1 About these instructionsThese operating instructions provide information on the handling of the LCOS Unmanaged Switch over its entire product life cycle, from delivery to disposal. Other documents apply in addition to these operating instructions. (See also chapter „2.7 Applicable documents“ on page 11) in this document. Please also refer to the data sheets associated with the products.If you have suggestions for improving this document, please contact the company Friedrich Lütze GmbH.
LCOS Unmanaged Switch ▪ General Information6TRANSPORTATION2 General Information2.1 Safety instructions and technical informationThis document contains several safety messages. Each safety message contains a defined signal word and a color. The color and the word are referring to an alert level. There are 4 levels. The safety messages point out hazardous situations and give information on how to avoid these.Additionally following symbols can be found. These refer to important technical information and instructions: 2.2 CopyrightThis document is intended for the operator and his employees. It is forbidden to give the content to a third party, to duplicate, exploit or impart it. The Friedrich Lütze GmbH has to allow it explicit in writing.General data, text, images and drawings are copyrighted and are liable to the industrial property right. Contravention can be prosecuted. The named brands and product names in this document are trademarks or registered trademarks by titleholder. 2.3 Disclaim of LiabilityThe document was written under consideration of the applied standards, regulations and the current state of technology. The content is verified of accuracy. Discrepancies are not excluded. For those discrepancies we disclaim liability. Applicable changes and additional information will be in the next version of the document.The Friedrich Lütze GmbH does not assume liability for any damages and accidents of following reasons:Indicates a hazardous situation, which if not avoided will result in death or serious injury.Indicates a hazardous situation, which if not avoided can result in death or serious injury.Indicates a hazardous situation, which if not avoided can result in minor or moderate injury. Indicates a situation which could damage the product or the environment. This notice does not apply to personal injury.Refers to important technical information. This indicates to the user a specific action that must be performed to operate the device safely.Refers to the use of different tools.
LCOS Unmanaged Switch ▪ General Information7TRANSPORTATION▪ Nonobservance of the document▪ Untrained and unqualified personnel▪ Non conventional use▪ Non approved reconstructions and functional modifications of the product▪ Using non original or non admitted parts or equipment 2.4 Standards and normsLCOS Unmanaged switches are state of the technology and comply with the applicable safety regulations and the corresponding harmonized European standards (EN).(As at: 21.08.2018)EN 61131-2 Industrial-process control systems - Instruments with analogue inputs and two- or multi-state outputs - Part 2: Guidance for inspection and routine testing (IEC 65B/957/CD:2014) EN 61000-6-2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments (IEC 77/488/CDV:2015); German version FprEN 61000-6-2:2015 EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments (IEC 61000-6-4:2006 + A1:2010); German version EN 61000-6-4:2007 + A1:2011UL 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements (IEC 61010-1:2010 + Cor. :2011); German version EN 61010-1:2010  UL 61010-2-201(IEC 61010-2-201)Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 2-201: Particular Requirements for Control Equipment (IEC 65/582/CD:2014)The current issue status of the standards as well as further information on the product can be found in the respective data sheets.The constantly updated data sheets can be found at www.luetze.comEnter either the product name: LCOS Unmanaged Switch or this article number: 77920* into the search field.Here you will always find the latest documents (e.g. operating instructions) for the products as well as further articles and technical information.
LCOS Unmanaged Switch ▪ General Information8TRANSPORTATION2.5 Scope of validity of the manualThese operating instructions apply exclusively to devices with the following item number(s):1.) 779200.0401 / 779201.0401 - LCOS Unmanaged Switch 4 ports 2.) 779200.0801 / 779201.0801 - LCOS Unmanaged Switch 8 ports The 9-digit article number of the device can be taken from the first number on the Identification label. 2.5.1 Identification labelThe identification plate contains the required markings for the respective product and provides important technical data. The identification plate, which has the following structure, is located on the device::Abb. 1: Identification plate (example)The identification label contains the following information:1. Part number2. Assembly designation / module description3. Module Description4. Version number / Firmware Version (SW) (Empty in the example)5. Hardware Revision (HW)6. Serial number (X) / place of manufacture (YYY) / batch identification (Z) 7. Company address / place of production (YYY: "LUT" for Weinstadt and "EQQ" for Czech Republic)8. Block diagram9. Company name / web address10.Approvals / declarations of conformity (e.g. CE marking, UL, etc.)11.2D barcode with product informationNote the identification label.▪ The identification label should always be visual ▪ If there is a fault, the part number and serial number are needed.
LCOS Unmanaged Switch ▪ General Information9TRANSPORTATION2.6 Approvals2.6.1 Notes on CE labelling Observe the original information signs, inscriptions, identification plates and stickers. Keep them in a readable condition.The devices comply with the provisions of the following European Directive: 89/336/EEC Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility (amended by Directives 91/263/EEC, 92/31/EEC and 93/68/EEC). The EU Declaration of Conformity is kept available for the competent authorities in accordance with the above-mentioned EU directives:Friedrich Lütze GmbHBruckwiesenstraße 17-1971384 Weinstadt GERMANY / DEUTSCHLANDTelefon: +49 7151 60530Telefax: +49 7151 6053277E-Mail: info(at)luetze.de The product can be used in industry.- Immunity to interference: EN 61131-2:2007 Zone B - Emitted interference:   EN 61131:2007 und CFR-47 Part 15, Subpart B, class BStrict compliance with the assembly guidelines specified in this description and operating instructions is a prerequisite for compliance with the EMC limit values.
LCOS Unmanaged Switch ▪ General Information10TRANSPORTATION2.6.2 FCC Warning Statements 1. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause un-desired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to ope-rate the equipment.2. Any Changes or modifications not expressly approved by the party respon-sible for compliance could void the user's authority to operate the equip-ment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:▪ -Reorient or relocate the receiving antenna.▪ -Increase the separation between the equipment and receiver.▪ -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.▪ -Consult the dealer or an experienced radio/TV technician for help.
LCOS Unmanaged Switch ▪ General Information11TRANSPORTATION2.7 Applicable documents2.7.1 Observe other applicable documentsWhen operating the LCOS Unmanaged Switch, please also observe all operating instructions enclosed with other components of your system.For reasons of clarity, we would like to point out that these operating instructions cannot describe all conceivable problems in connection with the use of this device. Should you require further information or encounter special problems that are not dealt with in sufficient detail in the operating instructions, you can request the necessary information about service from Lütze. (See chapter „14 Service“ on page 48)Further documents are valid in conjunction with these operating instructions. We accept no liability for damage caused by non-observance of these instructions.Always keep these operating instructions and the other applicable documents (e.g. data sheets, package inserts, declarations of conformity, etc.) at hand so that they are available when required.This applies until the device is disposed of. Hand over all documents in case of sale, distribution or rental of the device.
LCOS Unmanaged Switch ▪ Safety12TRANSPORTATION3Safety3.1 Contents of the operating instructionsThese operating instructions must be read and observed before any work is carried out on or with the units. This applies to all persons who come into contact with the devices. Trained personnel and specialists, especially electricians (see also chapter „3.5.1.3 Electrically qualified persons“ on page 14) who have already worked with similar equipment should also have read and understood the manual. 3.2 Applicable documents3.3 Appropriate UseThe LCOS Unmanaged Switches are designed for industrial use in factory, machine and building automation.Due to the modular design, the devices in the LCOS system can be supplied either via existing connectors or via the power bus. Due to the possibility to supply the devices with AC, they can also be used in building automation.These instructions must be read and understood before installing, operating or maintaining the device.Risk of injury and damage to property due to non-observance of the applicable documents*, in particular the safety instructions in the respective package inserts.This operating instruction alone is not sufficient if the modules are operated in one system.To avoid injury and damage, read the applicable and associated documents before you plan the system. *A list of other applicable documents can be found in chapter „2.7 Mitgeltende Unterlagen“ on page 11The products may only be used for the applications specified here in this operating instruction, in the catalogue and in the associated technical documentation.Use of the device in a manner not specified by the manufacturer may impair the protection and safety provided by the device.The device is used exclusively for the purpose contractually agreed between manufacturer and user. Any other use or use beyond this is considered improper use. The manufacturer is not liable for any damage resulting from this.
LCOS Unmanaged Switch ▪ Safety13TRANSPORTATIONAlso note the following:The intended use also includes the procedure according to the operating instructions. Any other or extended use is considered improper and therefore improper. In this case, safety and its protection can be impaired. The company Friedrich Lütze GmbH is not liable for any damages arising from this.Intended use also includes:▪ Observing all notes in the operating instructions▪ Observing all safety instructions3.4 Product lifeThe product life cycle of LCOS Unmanaged Switches is based on the EN/IEC 61709 is calculated and defined: 3.4.1 LCOS-SW-4P / 4-Port Ethernet Switch VersionMTBF (EN/IEC 61709, 45 °C) = 378,7 Years3.4.2 LCOS-SW-4P / 8-Port Ethernet Switch VersionMTBF (EN/IEC 61709, 45 °C) = 349,0 YearsThe results are valid under the following conditions:▪Automotive or industrial environment without extreme dust pollution and pollutants (SN 29500)▪45°C average ambient component temperature▪Continuous operation 8760 h per yearCorrect and safe operation of the product requires proper transport, storage, installation and assembly as well as careful operation and maintenance.The permissible ambient conditions must be observed. These data are given in the data sheets.Operate the devices only in accordance with this intended case and only in conjunction with the third-party devices and components recommended or approved by us. The devices may only be connected to the supply voltage printed on the identification plate. To reduce or avoid risks, please ask in case of doubt whether the third-party devices and components used are approved or recommended by us.
LCOS Unmanaged Switch ▪ Safety14TRANSPORTATION3.5 AddresseesThis operating instruction is directed towards planers, project managers and programmers, as well as to staff authorized to commission, operate and maintain the devices and systems. A distinction is made between various qualification levels of the staff.3.5.1 Operating PersonnelThe operating instructions are directed at the operator and the personnel with the following areas of competence:   3.5.1.1 Trained EmployeeThe employee was trained by the employer on the task and possible hazardous situations. The employee does not have any technical knowledge.3.5.1.2 ExpertsThe employee has a technical education, knowledge and/or experience in the required field. The employee is capable to perform specific operations on and with the product.3.5.1.3 Electrically qualified persons The employee has a technical education in the required field. The employee is capable to perform special operations on and with the product.The different sections of the document refer to the qualification level of the operating personnel.According to European Standard EN 50110-1:2008-09-01 Section 3.2.3 Working range CompetencyInstallation, transport and storage ExpertsCommissioning, decommissioning Trained EmployeeOperation Trained EmployeeServicing and maintenance ExpertsTroubleshooting ExpertsRisk of injury by usage through insufficient qualified operating personnel! Misusage through performed insufficient or qualified personnel can cause property damage and personal injuries.▪ Tasks which apply special procedures should be done by trained and qualified employees or experts, especially electricians.(according to EN 60204-1)The individual sections refer to the qualification level of the personnel.
LCOS Unmanaged Switch ▪ Safety15TRANSPORTATION3.6 Responsibility of the operatorSince the device is used in a commercial area, the operator of the device is subject to the legal obligations for occupational safety: ▪ The operator of the device is obliged to instruct the operating personnel and to inform himself about the industrial safety regulations. ▪ The operator must ensure that safety, accident prevention and environmental protection regulations are observed. ▪ The operator must make an appropriate risk assessment on the ▪ Workplace/location to detect and warn of special hazards. ▪ The manual must be kept in the immediate vicinity of the device. ▪ The information in the operating instructions must be followed. ▪ The device may only be operated in technically perfect condition.3.7 Changes and modifications to the devicesDo not make any changes or modifications to the devices that have not been expressly and in writing previously approved by Friedrich Lütze GmbH.3.8 Safety device3.9 Special safety notesLCOS Unmanaged Switches are state of the technology and comply with the applicable safety regulations and the corresponding harmonized European standards (EN) - See also chapter „2.4 Standards and norms“ on page 7.The following applies to the users:▪ relevant and national accident prevention regulations▪ EC directives or other country-specific regulationsModifications and conversions lead to personal injury and property damage! Unauthorized modifications to the product may result in electric shock or injury and destroy the product.  ▪ Do not make any changes or modifications to the product. ▪ If a modification or change cannot be avoided, have the modification approved in writing by Friedrich Lütze GmbH.Sabotage of the devices can lead to serious errors in the overall system. Install the LCOS Unmanaged Switch in such a way that it is not freely accessible to unauthorized personnel and other persons.Do not bypass or bypass the protective and safety devices. Overvoltage can cause electric shocks and destroy the equipment.
LCOS Unmanaged Switch ▪ Safety16TRANSPORTATION▪ generally accepted safety rules▪ general ESD regulations.The unit is to be connected only to internal Ethernet networks without exiting a facility and being subjected to TNVs.To avoid electric shock, this device may only be connected to Ethernet networks within a building that are not connected to TNV circuits. Do not use a telephone line voltage (TNV)! (This note is particularly relevant for North America and Canada.)The input/output connections comply with the Safety Extra Low Voltage (SELV) guidelines for extra-low voltage devices. With TNV circuits, higher voltages must be expected, e.g. due to lightning strikes. Therefore, they must not be connected to SELV circuits.Short-circuits and electric shocks due to incorrect application of the voltage! Current can injure persons and destroy the device. Before commissioning, disconnect the entire system from the power supply and check the connections after applying power.Accidents during installation or maintenance due to electrical voltages! When carrying out installation or maintenance work, disconnect the modules from the power supply (pull out the mains plug). This prevents accidents caused by electrical voltages.Risk of injury from electric current. Current can injure persons and destroy the device. For this reason, disconnect the system from the power supply before installation.Risk of injury and material damage through non-observance of the operating instructions.Always read the operating instructions before planning the system in order to avoid or reduce risks and damage. (The instruction leaflet does not replace the operating instructions of the product.You can also find these operating instructions at www.luetze.com. For electrical welding work on frames, all assemblies and their connections must be disconnected.If electronic assemblies are mounted on the frame, then all connections to and from these assemblies must be disconnected beforehand. Non-observance can destroy the devices by equalising currents.
LCOS Unmanaged Switch ▪ Safety17TRANSPORTATION3.10 Further safety notes Follow the ESD regulations.Only use certified components. Only this way a reliable functioning is ensured.Follow the valid safety regulations and general regulations regarding the technical standards.The conductor size has to be selected dependig on the load current and must be conform with international and national ruls and standards.Attention! The supply cable must be suitable for an operating temperature range of -25 °C to +70 °C. The connecting cables must be designed for the ambient temperature. For UL applications: Ambient temperature: +70 °C The device has to be installed in a fire enclosure depending on the end user application.The device is intended to be used in indoor applications and be mounted in cabinets.
LCOS Unmanaged Switch ▪ Product Overview18TRANSPORTATION4Product Overview4.1 Construction types4.1.1 779200.0401 - Unmanaged Switch 4 ports Abb. 2: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 4 ports 4.1.2 779200.0801 - Unmanaged Switch 8 ports Abb. 3: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 8 ports4.1.3 779201.0401 - Unmanaged Switch 4 ports Abb. 4: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 4 ports 4.1.4 779201.0801 - Unmanaged Switch 8 ports Abb. 5: 10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS, unmanaged Switch 8 ports 
LCOS Unmanaged Switch ▪ Product Overview19TRANSPORTATION4.2 Overview of product features4.2.1 LCOS Unmanaged Ethernet SwitchesThe LCOS-SW-4P or LCOS-SW-8P Unmanaged Ethernet Switch is a switch for use in industrial environments. It supports ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s. The switch modules enable the construction of switched Ethernet networks according to the IEEE 802.3 or 802.3u standard with twisted-pair cables. The switch modules can be mounted directly on the top-hat rail via a function carrier and are powered either via the LCOS power bus or the 3-pole connection terminal. With their compact design, the modules can be mounted in a terminal box. The LCOS-SW-4P devices have four 10/100 Mbps twisted pair ports (10/100BASE-TX, RJ45 connectors) and the LCOS-SW-8P devices have eight 10/100 Mbps twisted pair ports (10/100BASE-TX, RJ45 connectors). Twisted pair devices or other TP/TX segments can be connected to the ports. The TP ports support auto negotiation, auto polarity and auto MDI/MDI-X. In addition, the devices evaluate the Ethernet frame-based priority data (Qos) in order to forward time-critical signals more quickly. The power consumption is significantly reduced by an automatic switch-off of the unused ports, but even at full load the power consumption of the 8 port version remains below 2W. The extended operating temperature range allows operation from - 25 °C to + 70°C ambient temperature.4.2.2 Product Features of LCOS Unmanaged Ethernet Switches▪ AC/DC 24V supply voltage ▪ Variable supply voltage supply - Power bus or - 3-pole plug-in terminal Push-In ▪ Can be used as a stand-alone module or in the "Lütze Communication System".▪ Compact design and universal application ▪ QoS - Quality of Services ▪ Extended temperature range▪ CE - Declaration of Conformity▪ UL - Approval ▪ FCC - Approval
LCOS Unmanaged Switch ▪ Product Overview20TRANSPORTATION4.2.3 LCOS - Modular housing systemThe LCOS Unmanaged Ethernet switches can be used either as a stand-alone module or in the "Lütze Communication System". 4.2.4 Product description of the modular housing system LCOSLCOS is a modular housing system consisting of individual modular components that can be assembled. The functionaries and - housings, as well as various modules for data and power supply are available in different widths. The housings can be equipped with their own printed circuit boards as required. Information on the equipment and size of these can be found in the separately available "LCOS Modular housing system manual", which is available in the Lütze Online Catalogue.A wide variety of front panels and cut-outs on the function housings provide options for operating elements and a wide variety of plug-in terminals. In addition, the modules can be bridged and supplied via a feed module so that a complete system can be set up. Abb. 6: Overview modular enclosure system, modules not bridged
LCOS Unmanaged Switch ▪ Product Overview21TRANSPORTATION4.3 Function carrier (with power module)The function carrier is the basis for the LCOS Unmanaged Switch. The LCOS Unmanaged Switch is plugged onto the function carrier and can then be snapped onto the DIN rail. The power and data module for setting up the bus system is also located in the function carrier. 1Power module2 Labeling Plates3Side covers123
LCOS Unmanaged Switch ▪ Transport and storage22TRANSPORTATION5 Transport and storagePlease note the following:Proper and safe operation of the products requires proper transport, storage, installation, assembly, installation, commissioning, operation and maintenance. Risk of property damage. Risk of damage due to improper handling during transport and storage.  The device must be protected against moisture, unsafe packaging (mechanical damage), dust and electrostatic discharge. Avoid product damage due to incorrect storage conditions.Protect the equipment from extreme temperatures and humidity. Store the units in dry rooms between -40 and 85°C. Make sure that the humidity is less than 75%. Product damage due to unsafe packaging.Make sure that the devices are securely packed for transport. This is the only way to absorb possible shocks.Product damage caused by dust.Store and transport the units in a dust-free environment. Dust can easily settle on the electronic components and lead to a possible defect of the devices.Product damage due to electrostatic discharge.Store and transport electronic components only in an ESD safe environment and special packaging.
LCOS Unmanaged Switch ▪ Scope of delivery23TRANSPORTATION6 Scope of deliveryCheck the completeness of the delivery using the following list. 6.1 The LCOS Unmanaged Switch consists of:6.1.1 LCOS Unmanaged Switch 1. Device: LCOS Unmanaged (Industrial Ethernet) Switch*2. Functional support 22.5 mm, not modularly expandable 3. (only for 779201.0401 and 779201.0801)4. Instruction leaflet (compact operating instructions for the module)6.1.2 LCOS Unmanaged Switch Documentation1. Operating instructions (PDF, online version)2. Data sheets (PDF, online version)6.2 Accessories   If any of the parts listed below is missing or damaged, please contact the service department. (chapter „14 Service“ on page 48) * Part-No. Type Terminati-on (data)Included accessories779200.0401 LCOS-SW-4P 4 x RJ 45779200.0801 LCOS-SW-8P 8 x RJ 45779201.0401 LCOS-SW-4P 4 x RJ 45 LCOS-FT-PE-225-00-00-1779201.0801 LCOS-SW-8P 8 x RJ 45 LCOS-FT-PE-350-00-00-1You can also find these operating instructions and data sheets at www.luetze.com.In the search field, enter either the product name: LCOS Unmanaged Switch or the product number: 77920*To avoid malfunctions, only use original accessories.In the enclosed package insert or corresponding data sheet (online) you will find the current accessories for the respective product. Depending on the version of the product, no corresponding function carriers or other accessories are included in the scope of delivery.
LCOS Unmanaged Switch ▪ Scope of delivery24TRANSPORTATION6.3 Checking the deliveryCheck the outer packaging for possible transport damage. Unpack the product carefully. ▪ Check the package for completeness.▪ Check the individual parts for transport damage. Observe ESD regulations when unpacking.Install and use only undamaged products.Do not use damaged parts, a function according to the specifications of the device is then no longer guaranteed.If damaged parts are used, the following problems may occur:- Accidents and personal injuries- Loss of approvals- Violation of EMC regulations- Damage to the device and other componentsFor more information, please contact the service department. (See chapter „14 Service“ on page 48)
LCOS Unmanaged Switch ▪ Product Assembly25TRANSPORTATION7 Product Assembly7.1 LCOS Unmanaged Ethernet-Switches*Not in the scoop of delivery, see chapter „6.2 Accessories“ on page 23.**Internal connector to LCOS-FT... (power supply)7.1.1 Standalone VersionNo. Description1Connector X10, 5-pole (internal)**2 X9: Push-In terminal Power Supply, 3-pole, RM 5.083Labeling Plates*4 LED power supply54x Rj456 8x Rj457Function carrier (only at 779201.0401/779201.0801 included)/&266:3/&266:3
LCOS Unmanaged Switch ▪ Product Assembly26TRANSPORTATION7.1.2 System with Powerbus7.2 LED status displays7.2.1 LED power supply7.2.2 LEDs Link/ActivityNo. Description8Function carrier 35 mm, can be expanded with modules with PE direct contact, power module9 Function carrier 22.5 mm, can be expanded with modules with PE direct contact, power module10 Side cover for function carrier 11 Power bridge 1-pole insulated – 4x per function carrier'&3RZHUEXV  Color Status Activity Operating statusgreen on ON OK – Switch active off OFF Switch turned off – no/ low supply voltage Color Status Activity  Operating statusgreen on link established The port of the switch is connected to a network subscriber.off no link is establishedThe port of the switch has no connection to a network subscriber.blinking active data traffic Data is exchanged on this port of the switch.
LCOS Unmanaged Switch ▪ Technical Data27TRANSPORTATION8 Technical Data8.1 Identification 8.2 Description 8.2.1 LCOS-SW-4P10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS 4 Fast Ethernet ports, Broadcast storm protection AC/DC 24 V, extended temperature range 8.2.2 LCOS-SW-8P10 / 100 Mbit, auto negotiation, Auto MDI/MDI-X, QoS 8 Fast Ethernet ports, Broadcast storm protection AC/DC 24 V, extended temperature range 8.3 Communication  8.4 Safety 8.5 General Type:  LCOS-SW-4P / LCOS-SW-8PPart-No.: 779200.0401 / 779200.0801779201.0401 / 779201.0801Standard:  IEEE 802.3, 802.3u, 802.3xLAN: 10 / 100 Base-TXCable length (segment): max. 100 mTransfer rate: max. 100 Mbit/sConnection technology (data):4 x RJ45 / 8 x RJ45 Status display communication:Link activityReverse voltage protection: YesIsolating voltage Ethernet/supply/FE1000 VRated voltage UNAC/DC 24 V (SELV, PELV)Rated frequency  50/60 Hz with AC supply Operation voltage range   AC 19.2–28.8 V / DC 18–31.2 V Connection technology (supply) 3-pin terminal clamp, push-in, RM 5.08 or via LCOS-FT Powerbus Power consumption  1.5 W
LCOS Unmanaged Switch ▪ Technical Data28TRANSPORTATIONProtection class IP20Over voltage category  IIDegree of polution  2Application height  2000 m Relative humidity (operation) 5 % - 95 % (non-condensing)Relative humidity (storage)  0 % - 95 % (non-condensing)Operation temperature range -25 °C – +70 °CStorage temperature range -40 °C – +85 °CDimensions (w × h × d)   35 x 110 x 102 mmHousing material   PA 6.6 (UL 94 V-0, NFF I2, F2)Mounting   connected to LCOS function carrier, hat rail mounting EN 60715 Installation position   verticallyInstallation space above: 30 mm (for mounting)below: 30 mm (for mounting)sideways: 0 mmStandards   See chapter „2.4 Standards and norms“ on page 7, compare also current data sheet.Approvals   CE cULus in preparation DNV GL in preparationFCC(Compare also current data sheet.) The complete and current technical data can be found in the corresponding data sheets.Specifications are subject to change without notice. Make sure you always work with the latest documents. Data sheet779200.0401Data sheet779200.0801Data sheet779201.0401Data sheet779201.0801You can also find these operating instructions and data sheets at www.luetze.com.In the search field, enter either the product name: LCOS Unmanaged Switch or the product number: 77920*
LCOS Unmanaged Switch ▪ Mounting / Dismounting29TRANSPORTATION9 Mounting / Dismounting9.1 Installation position The LCOS Unmanaged Switch, plugged onto an LCOS function carrier, is mounted vertically on a 35 mm DIN rail (TS 35).  Risk of injury and damage to property from electric current. Current can injure persons and destroy the modules (assemblies).▪ Disconnect the system from the power supply before assembly and disassembly.With AC supply, an external overvoltage protection must limit the voltage between supply and VU to less than 1000 V.For UL applications: Ambient temperature: +70°CThe module must be installed in a fire protection housing suitable for the end application. The device is intended to be used in indoor applications and be mounted in cabinets.Ensure that the electrical installation complies with local or national safety regulations. Observe the minimum distances!Mount the unit at a distance of at least 30 mm upwards and downwards (0 mm to the side) from other units to ensure proper ventilation.
LCOS Unmanaged Switch ▪ Mounting / Dismounting30TRANSPORTATION9.2 MountingThe LCOS Unmanaged Switch has protection class IP20 when installed and is therefore suitable for use in control cabinets. The device is designed to snap onto / snap onto a 35 mm DIN rail (also called TS 35 - according to DIN EN 60715). A top-hat rail is a mounting rail with a U-shaped or hat-like profile. In English the DIN rail is called DIN rail.  9.2.1 Safety notices Environment  The device may only be installed by competent and qualified personnel. This work step may only be carried out by at least trained personnel in compliance with the safety regulations.The device may only be operated at the specified ambient temperature and at the specified relative humidity (non-condensing). Select the mounting location so that the climatic limit values specified in the technical data are observed. Use only in an environment up to pollution degree 2 (IEC 60664-1).
LCOS Unmanaged Switch ▪ Mounting / Dismounting31TRANSPORTATION9.2.2 DIN rail mounting 9.2.2.1 Variants of the LCOS Unmanaged Switches V Risk of injury and damage to property from electric current. Current can injure persons and destroy the modules (assemblies).▪ Disconnect the system from the power supply before assembly and disassembly.This step must be carried out by at least trained stuff.With the variants with function carriers (779201.0401 and 779201.0801), the switch can be mounted directly on a DIN rail. The plug-in terminal can be removed for easier wiring.779201.0401 779201.0801The variants with function carriers can also be operated on the power bus by exchanging the function carrier.The variants without function carriers (779200.0401 and 779200.0801) can be supplied either via the power bus or the plug-in terminal. The matching function carrier is available as a separate accessory.779200.0401 779200.0801
LCOS Unmanaged Switch ▪ Mounting / Dismounting32TRANSPORTATION9.2.2.2 LCOS function carrier Function carrier 22.5 mm, Locking slide in open position 9.2.2.3 Mounting the LCOS housing onto the function carrier* How you attach the functional housing to the function carrier.* Function carrier only for 779201.0401 / 779201.0801   included in delivery, see accessoriesThe function carriers are delivered with open locking slides. Check the position of the locking slide before mounting the module.The locking slides of the function carriers are in open position when delivered. Check the position of the locking slide before mounting.1. Pull both pull-tabs as far as possible.2. Plug the function housing onto the function carrier.3. Push the pull-tabs into the housing as far as possib-le.Remove the functional housing in reverse order.
LCOS Unmanaged Switch ▪ Mounting / Dismounting33TRANSPORTATION9.2.2.4 Mounting of Function carriers1. Place the function carrier on the up-per part of the top hat rail.2. Pivot the function carrier to the bottom of the top hat rail.3. Push the locking slide to the top.The locking slide is locked.
LCOS Unmanaged Switch ▪ Mounting / Dismounting34TRANSPORTATION9.2.3 Dismounting of function carriers from top-hat railsRisk of injury and damage to property from electric current. Current can injure persons and destroy the modules (assemblies).▪ Disconnect the system from the power supply before assembly and disassembly.This step must be carried out by at least trained staff.For this step you will need a 3.5 - 4 mm flat-tip screwdriver.1. Put the screw driver into the notch of the locking slide.2. Lever the screw driver up. The locking slide will unlock.3. Pivot the function carrier to the top of the top hat rail.12
LCOS Unmanaged Switch ▪ Mounting / Dismounting35TRANSPORTATION4. Take the function carrier off the top hat rail.
LCOS Unmanaged Switch ▪ Mounting / Dismounting36TRANSPORTATION9.3 Wiring9.3.1 Safety notes Shielding ground    The device can be powered by function carrier LCOS-FT... to AC/DC24V, all voltages must be in conformance to SELV/PELV.The conductor size has to be selected dependig on the load current and must be conform with international and national ruls and standards.Attention! The supply cable must be suitable for an operating temperature range of -25 °C to +70 °C. The connecting cables must be designed for the ambient temperature. To ensure UL certification of the complete module, only use the plug-in terminals recommended by us. See also chapter "6.2 Accessories" on page 23)A screwdriver is required for wiring. (e.g. slotted screwdriver 3 mm)▪ Push-In terminal The shielding ground of the connectable twisted-pair cables is electrical-ly conductively connected to the front panel. When operating the device via the plug-in terminal, connect the functional earth (FE) for proper functioning of the device. When connecting a cable segment with contacted shielding braid, check for possible ground loops. Stripping Length Conductor Size X9: 3-pole (RM/CS 5.08)solid 0.08 ... 2.5 mm² AWG 28 – 12X9: 3-pole (RM/CS 5.08)fine stranded with ferrule0.08 ... 2.5 mm²  AWG 28 – 121010
LCOS Unmanaged Switch ▪ Mounting / Dismounting37TRANSPORTATION9.4 Pin assignment X1 ... X8  Pin Color code wireAssignment10BASE-T100BASE-T1WHT/ORG TX+2ORG TX-3WHT/GRN RX+4BLU5WHT/BLU RX-6GRN7WHT/BRN8BRN$UWLNHO3DUW/&266:3;5;/('SRZHUVXSSO\JUHHQ6:,7&+(1*,1(9$&'&*1'9/&26)7'DWD,VRODWLRQ;)( ;9$&'&*1')(7;.9;;;[5-6KLHOG8PLQ[/LQN$FWLYLW\$UWLNHO3DUW/&266:3;5;/('SRZHUVXSSO\JUHHQ6:,7&+(1*,1(9$&'&*1'9/&26)7'DWD,VRODWLRQ;)( ;9$&'&*1')(7;.9;;;[5-6KLHOG8PLQ[/LQN$FWLYLW\;;;;$UWLNHO3DUW/&266:3;5;/('SRZHUVXSSO\JUHHQ6:,7&+(1*,1(9'DWD,VRODWLRQ;)(9$&'&*1')(7;.9;;;[5-6KLHOG8PLQ[/LQN$FWLYLW\$UWLNHO3DUW/&266:3;5;/('SRZHUVXSSO\JUHHQ6:,7&+(1*,1(9'DWD,VRODWLRQ;)(9$&'&*1')(7;.9;;;[5-6KLHOG8PLQ[/LQN$FWLYLW\;;;;/LQN3RUW6ZLWFK/LQN3RUW6ZLWFK
LCOS Unmanaged Switch ▪ Mounting / Dismounting38TRANSPORTATION9.5 Further information on the LCOS system (basics)System configuration1PE connection2 Supply voltage3Supply module4 Supply module - intermediate supply5PE connection6 Load Connection315642
LCOS Unmanaged Switch ▪ Mounting / Dismounting39TRANSPORTATION9.6 Coding of LCOS modulesTo assign the function housing to the regarding function carrier and also to prevent mistakes when assembling the modules, the function housing and the function carrier can be coded.1. Plug the coding pins into the slots of the function housing and the carrier.2. Set the coding pins of the function housing (1) and the carrier (2) to the same position. In the example on the right, position G was choosen.JKLMNOPIKJIPONML21
LCOS Unmanaged Switch ▪ Mounting / Dismounting40TRANSPORTATION9.7 Installing Data and Power BridgesIn the LCOS system it is possible to bridge single modules.Connect the modules regarding the application with1. a data bridge or2. a power bridge.Different combinations are possible.Two bridged function carriers 22.5 mm, The carrier to the right is not displayed.12Further information on the LCOS system can be found at www.luetze.comIn the search field, enter either the product name: LCOS System or this article number: 780700.575.1Here you will also find the LCOS System Manual "LCOS Modular housing system manual" in the download area.
LCOS Unmanaged Switch ▪ Commissioning - Hardware41TRANSPORTATION10 Commissioning - Hardware 10.1 Safety notes Power supply      The supply voltage is galvanically isolated from the housing. The devices can be supplied either via the energy bus X10 or the connection terminal X9. The power bus and the connection terminal are internally connected. Polarity is irrelevant. Commissioning of the hardware may only be carried out by qualified per-sonnel in compliance with the safety regulations.Only switch on a device when the housing is closed. Electric shocks and short-circuits due to incorrect voltage application.Before commissioning, disconnect the entire system from the power supply and check the connections after applying power. The devices may only be connected to the supply voltage printed on the identification plate. The devices are designed for operation with safety extra-low voltage.Accordingly, only SELV/PELV voltage circuits may be connected to the supply voltage connections.The earth connection of the device serves exclusively as functional earth (FE) according to EN 61131-2. Make sure that peripherals are suitable for the application environment.The connecting cables must be designed for the ambient temperature.If the switches are supplied with AC, surge voltages of up to 2000 V can be expected between the active conductors and earth. However, since the isolation voltage between functional earth (FE) and active conductors is only 1000 V, external overvoltage protection is required between the functional earth and at least one active conductor. This overvoltage protection must limit the voltage to 1000 V. Varistors of type 7N431K can be used for this purpose, for example.
LCOS Unmanaged Switch ▪ Commissioning - Hardware42TRANSPORTATION10.2 Safety notes HousingRisk of electric shock!The housing may only be opened by technicians authorised by Lütze. The upper and lower ventilation slots must not be covered so that the air can circulate freely. The distance to the ventilation slots of the housing must be at least 30 mm. Never insert pointed objects (narrow screwdrivers, wires or similar) into the inside of the product! There is a risk of electric shock.  The housing must be installed in a vertical position.
LCOS Unmanaged Switch ▪ Operation43TRANSPORTATION11 OperationThe device is delivered ready for operation.11.1 Functional description The ports of the LCOS Switch represent a terminal device connection for the connected LAN segment. You can connect individual devices or entire network segments. 11.2 Frame-Switching functionalities11.2.1 Store and Forward All data received by a switch is stored and checked for validity. Invalid and faulty data packets are discarded. Valid data packets are forwarded. Data packets with a length of up to 1552 bytes are supported. The packet buffer size is 448k bits.11.2.2 Multi-address capability A switch learns all source addresses per port. Only packages with ▪ unknown addresses▪ these addresses or ▪ a multi-/broadcast address in the destination address field are sent to this port. Up to 1000 addresses can be stored simultaneously. This is necessary if more than one terminal is connected to one or more ports. This allows several independent subnets to be connected to one switch.Operation must be carried out by at least trained personnel.Do not touch the housing during operation or shortly after switching off. Hot surfaces can cause injuries.Proper and safe operation of the product requires careful operation and maintenance.With the connection of the supply voltage you put the switch into operation.
LCOS Unmanaged Switch ▪ Operation44TRANSPORTATION11.2.3 Tagging (IEEE 802.1Q) For the VLAN and prioritisation functions, the IEEE 802.1 Q standard provides that the VLAN tag is integrated into a MAC data frame. The VLAN tag consists of 4 bytes (2 bytes Tag Protocol Identifier TPID, 2 bytes Tag Control Information TCI). It is inserted between the source address field and the type field. Data packets with VLAN tag are transmitted unchanged by the switch.11.3 Specific functions of the Ethernet interface11.3.1 Polarity reversal (Auto-Polarity) If the pair of receiving lines is incorrectly connected (RD+ and RD- reversed), the polarity is automatically reversed. 11.3.2 Auto MDI-MDIX The switch detects the transmit and receive line pair. The switch automatically switches the port output and port input to the corresponding line pairs. Therefore, it does not matter whether you use a cross-over or uncrossed cable to connect a device.11.4 Other functions and features11.4.1 Undervoltage cutoff The switch switches off when the voltage falls below a certain level to prevent malfunctions.11.5 Display elementsSee chapter „7.2 LED status displays“ on page 26.
LCOS Unmanaged Switch ▪ Operation45TRANSPORTATION11.6 Interfaces11.6.1 10/100 Mbit/s connection (TP Port)Four (LCOS-SW-4P) or eight (LCOS-SW-8P) ports allow the connection of end devices or independent network segments according to the IEEE 802.3 100BASE-TX / 10BASE-T standards. Pin assignment of the RJ45 socket: See chapter „9.4 Pin assignment“ on page 37.The unit is to be connected only to internal Ethernet networks without exiting a facility and being subjected to TNVs.To avoid electric shock, this device may only be connected to Ethernet networks within a building that are not connected to TNV circuits. Do not use a telephone line voltage (TNV)! (This note is particularly relevant for North America and Canada.)The input/output connections comply with the Safety Extra Low Voltage (SELV) guidelines for extra-low voltage devices. With TNV circuits, higher voltages must be expected, e.g. due to lightning strikes. Therefore, they must not be connected to SELV circuits.
LCOS Unmanaged Switch ▪ Maintenance - Hardware46TRANSPORTATION12 Maintenance - HardwareThe device is maintenance-free. Therefore, no inspection and maintenance inter-vals are necessary for ongoing operation. Opening or penetrating the device with any objects will void the warranty.For general questions about the product or repair requests, please contact us:Friedrich Lütze GmbHBruckwiesenstraße17-1971384 WeinstadtGERMANY / DEUTSCHLANDTelefon: +49 7151 60530Telefax: +49 7151 6053277E-Mail: info@luetze.deSwitch off the input voltage before installation, maintenance or conversi-on work and secure it against unintentional restarting.Prevent foreign objects from entering the device, especially metal parts such as screwdrivers, paper clips or needles, etc.Do not make any changes or attempt to repair the unit. Do not open the device!The replacement of defective hardware must be carried out by qualified personnel.In the event of malfunctions or damage, switch off the supply voltage im-mediately and send the device to the factory for inspection.The device does not contain any service components.
LCOS Unmanaged Switch ▪ Final Shutdown and Disposal47TRANSPORTATION13 Final Shutdown and DisposalMind the valid environmental standards of your country for the final shutdown and disposal.For the final shutdown the product has to be disassembled. Electric Parts must be disposed according to the national electronic scrap regulation. Dispose the product according to the terms of use and legal liability on your own cost and ex-empt the Friedrich Lütze GmbH from the responsibilities of §10 passage 2 Elek-troG (Take-back obligation of the manufacturer) and any third party in this content.If the product is handled to a commercial third party without any contractual ac-ceptance of the disposal, you have to take back the product after the final shut-down on your own cost and legal liability.The entitlement of indemnity from the Friedrich Lütze GmbH by the customer does not prescribe before two years after the final shut down of the product. The two year deadline of the suspension of statue forlimitations can start with a written message about the terms from you to the Friedrich Lütze GmbH.
LCOS Unmanaged Switch ▪ Service48TRANSPORTATION14 ServiceFor general questions about the product or repair requests, please contact us:Friedrich Lütze GmbHBruckwiesenstraße17-1971384 WeinstadtGERMANY / DEUTSCHLANDTelefon: +49 7151 60530Telefax: +49 7151 6053277E-Mail: info@luetze.deThe device does not contain any service components.In the event of malfunctions or damage, switch off the supply voltage im-mediately and send the device to the factory for inspection.
LCOS Unmanaged Switch ▪ Appendix49TRANSPORTATION15 Appendix15.1 Overview of other applicable documentsHere is an overview of the other applicable documents for the LCOS Unmanaged Switches:15.1.1 LCOS-SW-4P - 4-Port Ethernet Switch - 779200.0401 15.1.2 LCOS-SW-4P - 4-Port Ethernet Switch - 779201.0401 15.1.3 LCOS-SW-8P - 8-Port Ethernet Switch - 779200.0801 1. These operating instructions2. Data sheet for 779200.04013. Type Test Certification for 779200.04014. Material Confirmation for 779200.04015. CE certification6. UL certification7. FCC Test Report1. These operating instructions2. Data sheet for 779201.04013. Type Test Certification for 779201.04014. Material Confirmation for 779201.04015. CE certification6. UL certification7. FCC Test Report1. These operating instructions2. Data sheet for 779200.08013. Type Test Certification for 779200.08014. Material Confirmation for 779200.08015. CE certification6. UL certification7. FCC Test Report
LCOS Unmanaged Switch ▪ Appendix50TRANSPORTATION15.1.4 LCOS-SW-8P - 8-Port Ethernet Switch - 779201.0801 15.2 Explanation of abbreviations used1. These operating instructions2. Data sheet for 779201.08013. Type Test Certification for 779201.08014. Material Confirmation for 779201.08015. CE certification6. UL certification7. FCC Test ReportAcronym Meaning AC alternating current, term for alternating current, in particular ac-cording to specifications for alternating voltageDC the term direct current for direct current; it is also used for di-rect voltageDIN The German Institute for Standardization e.V. (DIN) is the most important national standards organisation in the Federal Repu-blic of Germany.ElektroG The Electrical and Electronic Equipment Act (ElektroG) imple-ments the WEEE directive of the EU on handling electronic wa-ste in Germany.EMC Electromagnetic compatibility; it refers to the absence of inter-ference between electrical or electronic equipment and its en-vironment.EN European standard, the standardization of CEN, CENELEC and ETSIESD Electrostatic Discharge - Electrostatic discharges are voltage punctures caused by large potential differences. FE Functional earth is often used to install an electrical system in an electromagnetically compatible manner (EMC). Grounding one or more points in a network, in a system or in equipment for purposes other than electrical safety.IEC International Electrotechnical Commission, a standardization body for electrical engineeringIEV International Electrotechnical Vocabulary, IEV. The Internatio-nal Electrotechnical Dictionary is published by the International Electrotechnical Commission (IEC) to standardize the termino-logy of electrical engineering. (http://www.electropedia.org/)IP20 „International Protection“, or „Ingress Protection“), internatio-nal classification of protection of electrical equipment against dust and waterLED Light-emitting diode
LCOS Unmanaged Switch ▪ Appendix51TRANSPORTATIONMbit The unit of measurement is called "bit" and has - according to IEC - "bit" as a unit symbol. Here used for the specification of data rates e.g. Mbit/s for megabits per second. (Mega stands for one million).PE Protective Earth, for protective conductors in electrical en-gineeringRx Receiving lineTS 35 DIN rail (35 mm) - DIN rail is a mounting rail with a U-shaped profile. (The profile resembles a hat.) Tx Transmission line ZIP The ZIP file format (zipper) is a format for losslessly compres-sed files, a data compression format
LCOS Unmanaged Switch ▪ Revision history52TRANSPORTATION16 Revision historySubject to technical changes. These operating instructions must be kept for further use!Revision Description Date0.00 New document 23/08/2018
© by Friedrich Lütze GmbH, Weinstadt, Germany  • Technical changes reservedwww.luetze.comDeutschlandFriedrich Lütze GmbHPostfach 1224 (PLZ 71366)Bruckwiesenstraße 17-19D-71384 WeinstadtTel.: +49 (0)7151 60 53-0Fax: +49 (0)7151 6053-277(-288)info@luetze.deÖsterreichLÜTZE Elektrotechnische Erzeugnisse Ges.m.b.H.Niedermoserstraße 18A-1220 WienTel.: +43 (0)1 257 52 52-0Fax: +43 (0)1 257 52 52-20office@luetze.atSchweizLÜTZE AGOststraße 2CH-8854 Siebnen/SZTel.: +41 (0)55 450 23 23Fax: +41 (0)55 450 23 13info@luetze.chUSALUTZE INC.info@lutze.comGroßbritannienLUTZE Ltd.sales.gb@luetze.co.ukFrankreichLUTZE SASlutze@lutze.frSpanienLUTZE, S.L.info@lutze.esChinaLuetze Trading (Shanghai) Co.Ltdinfo@luetze.cnKabel und LeitungenKabelkonfektionierungSchleppkettenKabelschutzKabelverschraubungenLSC-VerdrahtungssystemModul- und InterfacetechnikIndustrial EthernetEntstörtechnik, USV, Power SuppliesBahntechnik