Friedrich 2018 Floating Air Ductless Split Brochure
User Manual: Friedrich Friedrich Manuals and other s all in one place
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
FLOATING AIR® SERIES DUCTLESS SPLIT SYSTEMS www.friedrich.com THE EXPERTS IN ROOM AIR CONDITIONING SERIES Superb performance. Excellent value. You get both at exceptional pricing. INVERTER VARIABLE CAPACITY ADVANTAGES BETTER COMFORT, MORE ENERGY SAVINGS Inverter technology varies the compressor speed and the indoor fan speed, eliminating constant compressor start-ups/shut-downs that traditional systems require to maintain the temperature set point. Variable capacity inverter reaches setpoint faster and maintains precise temperature with minimal energy use. A. INVERTER ENERGY USAGE B. NON-INVERTER ENERGY USAGE Non-inverter technology is slow to reach setpoint, runs at full capacity, then shuts off and on with wide temperature swings. 5 / 5 YEAR WARRANTY Friedrich Floating Air ductless units feature a 5 year compressor warranty, as well as a 5 year parts warranty. setpoint TEMP RANGE The system can adjust capacity and cooling output to provide only the amount of cooling needed at a given time. The result is optimal comfort with low energy costs. TIME AUTO RESTART Auto restart function allows system to resume with previous settings in the event of a power shutdown. (Power supply must be restored). CONTINUOUS AIR SWEEP The indoor unit’s up/down air swing quickly disperses cool air to all four corners of the room to provide comfort throughout the room within a few minutes. Inverter vs. traditional HVAC systems TRADITIONAL SYSTEM INVERTER SYSTEM At initial start up, fixed capacity system slowly reaches the set temperature. At initial start up, utilizes variable capacity to quickly reach the set temperature. Complete shutdown once set temperature is achieved. Reduces capacity as set temperature is achieved. Temperature rises until 2nd system start up. System works at full capacity to again reach set temperature. Variable capacity maintains set temperature keeping space comfortable with reduced energy consumption. System cycles on and off continually to maintain the set temperature. CONTINUOUS AIR SWEEP OPTIMUM AIR FLOW Air is directed downward in heating mode and angled upward during cooling mode so the room feels more comfortable faster. Features for comfort and convenience year ‘round. In heating mode, units use approximately 1/4 of the energy required by electric heat. FEATURES • Inverter technology is more energy efficient and can self-adjust capacity to match cooling needs • Multiple operating modes including: auto, cool, dry, fan only and heat 115 volt models MWM09Y1J, MWM12Y1J • TURBO mode operates the unit at maximum performance to quickly bring the room to set temperature 230/208 volt models • 4 fan speeds heating or cooling: high, medium, low, “quiet”, plus auto-fan • Continuous ‘Air Sweep’ up & down • LCD remote MWM18Y3J, MWM24Y3J • 24-hour timer and sleep timer • Indoor unit will briefly display set or room temperature • Auto-restart after power interruptions • Auto-shut flaps close when unit is off for a sleek appearance • Washable antimicrobial air filters • 230 volt models will provide cooling in outdoor temperatures down to 5˚ F MWM36Y3J OPTIONAL ACCESSORY DFAC C LCD remote for cooling only operation of all Floating Air heat pump models. MRM09Y1J, MRM12Y1J REFRIGERATION LINE SETS MIN./MAX. LENGTHS REFRIGERATION LINE SET KITS Kit# Length (ft.) Liquid Suction System Model System Model Min. (ft.) Max. (ft.) MRM18Y3J, MRM24Y3J, MRM36Y3J TORQUE WRENCH SETTINGS Outside Diameter Torque T32150 15' 1/4″ 3/8″ MM09YJ MM12YJ MM09YJ 10 66 mm inch ft-lbs. N·m T32350 35' 1/4″ 3/8″ MM09YJ MM12YJ MM12YJ 10 66 Ø6.35 1/4 13~18 17.6~24.5 T42150 15′ 1/4″ 1/2″ MM18YJ MM24YJ MM18YJ 10 82 Ø9.52 3/8 25~30 33.3~41.2 MM18YJ MM24YJ T42350 35′ 1/4″ 1/2″ T52150 15′ 1/4″ 5/8″ T52350 35′ 1/4″ 5/8″ MM36YJ MM24YJ 10 82 Ø12.7 1/2 40~47 53.9~64.7 MM36YJ 15 98 Ø15.88 5/8 45~59 61.7~80.4 SPECIFICATIONS PERFORMANCE RATINGS 115 volt models 230/208 volt models MM09YJ MM12YJ MM18YJ MM24YJ MM36YJ INDOOR MODEL MWM09Y1J MWM12Y1J MWM18Y3J MWM24Y3J MWM36Y3J OUTDOOR MODEL MRM09Y1J MRM12Y1J MRM18Y3J MRM24Y3J MRM36Y3J SYSTEM MODEL NO. CAPACITY COOLING (RATED) Btu 9000 11800 18000 22000 33600 CAPACITY COOLING MIN - MAX Btu 3500~11000 3300~12500 4500~21000 6400~24000 7404~35997 COOLING AMPS 9.00 15.00 7.85/7.10 11.50/10.50 17.0/17.0 HEATING AMPS 9.50 15.5 11.77/10.65 12.80/13.00 16.5/16.5 SENSIBLE HEAT RATIO 0.79 0.73 0.77 0.77 0.75 CAPACITY HEATING (RATED) @ 47°F Btu 9800 13000 19200 24200 34600 CAPACITY HEATING MIN - MAX Btu 2500~11000 3400~13500 4000~23000 4100~26600 14979~35997 CAPACITY HEATING (RATED) @ 17°F Btu 5400 8500 13500 18600 20200 HSPF 8.6 8.6 8.5 8.5 9.0 SEER 16.0 16.0 16.0 16.0 18.0 12.0 9.4 11.0 10.0 8.20 1.69 2.96 3.80 4.50 7.40 588/441/306/206 736/647/530/412 54/49/44/37 EER MOISTURE REMOVAL Pts/h AIRFLOW (HIGH/MED/LOW/QUIET) CFM 330/277/224/188 341/288/235/200 471/400/330/271 SOUND RATING - INDOOR (HIGH/MED/LOW/QUIET) dB-A 41/37/35/32 43/39/35/32 48/43/38/34 49/43/39/34 SOUND RATING - OUTDOOR dB-A 53 55 56 53 65 OPERATING RANGE (HEATING) °F 5-75 5-75 5-75 5-75 -4-75 OPERATING RANGE (COOLING) °F 32*-113 32*-113 5-118 5-115 0~109 67 113 146 198 — 208/230/60/1 EST. YEARLY OPERATING COST U.S. $ ELECTRICAL DATA POWER SOURCE 115/60/1 115/60/1 208/230/60/1 208/230/60/1 MIN. AMPACITY V/Hz/Phase A 13 15 15 16 24 COOLING WATTS W 750 1260 1620 2200 4100 HEATING WATTS W 830 1320 2400 2800 3800 MAX. TD FUSE/BREAKER A 20 25 25 25 40 REFRIGERATION SYSTEM REFRIGERANT COMPRESSOR TYPE CONNECTIONS R410A R410A R410A R410A R410A Inverter Inverter Inverter Inverter Inverter Flare Flare Flare Flare Flare LIQUID LINE O.D. in 1/4” 1/4” 1/4” 1/4” 1/4” SUCTION LINE O.D. in 3/8” 3/8” 1/2” 1/2” 5/8” oz. 35.3 35.3 45.8 54.7 91.7 REFRIGERANT CHARGE FACTORY PRECHARGE ft 24.6 24.6 24.6 24.6 24.6 MIN. / MAX. LINE LENGTH ft 7 / 65 7 / 65 10 / 82 10 / 82 98 MAX. HEIGHT DIFFERENCE ft 32 32 32 32 32 DIMENSIONS & WEIGHT INDOOR UNIT WxHxD 34”× 12”× 8” 39 11/16”× 12 3/8”× 8” 53”x13”x10” NET WEIGHT lbs in 19 30”× 11”× 8” 19 26 33 42 SHIPPING WEIGHT lbs 25 25 35 44 52 OUTDOOR UNIT WxHxD in 33 3/8”× 24 1/4”× 12 5/8” 37 5/8 x 27 5/8 x 15 5/8 38 1/4”x 31”x 17” NET WEIGHT lbs 68 68 106 115 161 SHIPPING WEIGHT lbs 77 77 117 126 172 TOTAL NET WEIGHT lbs 87 87 132 148 203 TOTAL SHIPPING WEIGHT lbs 102 102 152 170 224 *Capacity is reduced as 32 degrees Fahrenheit is approached. Due to continuing research in new energy-saving technology, specifications are subject to change without notice. All Friedrich ductless split products require a licensed contractor for installation. Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com BRO_FADSS_2018 Printed in USA
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01 Create Date : 2017:09:20 09:34:33-05:00 Metadata Date : 2017:09:20 09:35:23-05:00 Modify Date : 2017:09:20 09:35:23-05:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:4fd77b46-fd51-49b2-a6ad-59afb7eb10e7 Original Document ID : xmp.did:e5a471c0-5621-e94b-9d93-7a88aa14bd06 Document ID : xmp.id:c3f0367c-fc5f-b14c-a5bf-919ed3e9df9a Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:22afa891-24e6-d147-a8f4-1f8eccfffab4 Derived From Document ID : xmp.did:0324d8a3-e234-3849-97a2-e447768ac5cf Derived From Original Document ID: xmp.did:e5a471c0-5621-e94b-9d93-7a88aa14bd06 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:09:20 09:34:33-05:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CC 2017 (Windows)EXIF Metadata provided by EXIF.tools