Installation

Instructions
Full Size Laundry Center
Gas & Electric
Before beginning installation, carefully read these instructions. This will simplify the installation
and ensure the laundry center is installed correctly and safely. Leave these instructions near the
laundry center after installation for future reference.

NOTE: The electrical service to the laundry center must conform with local codes and ordinances
and the latest edition of the National
Electrical Code, CSA C22.1

Electrical Code, ANSI/NFPA

70, or in Canada,

the Canadian

NOTE: The gas service to the laundry center must conform with local codes and ordinances and
the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, or in Canada, the Canadian
Natural

Gas and Propane Installation

Code, CSA B149. 1.

NOTE: The laundry center is designed

under ANSI Z21.5.1 or ANSI/UL 2158(latest edition) for HOME USE only. This laundry center is not recommended
applications such as restaurants or beauty salons, etc.

CAN/CSA C22.2
for commercial

For your safety the information in
this manual must be followed to minimize the risk
of fire or explosion or to prevent property damage,
personal injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquid in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
e Do not try to light any appliance.
t Do not touch any electrical switch; do not use
any phone in your building.
e Clear the room, building or area of all
occupants.
e Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
e If you cannot reach your gas supplier, call the
fire department.
Installation and service must be preformed by a
qualified installer, service agency or the gas
supplier.
Printed in U,S,A.

Contents
SUBJECT
Pre-lnstallation Requirements
Electrical Requirements
Water Supply Requirements
Drain Requirements
Exhaust System Requirements
Gas Supply Requirements
Location
Mobile Home Installation
Rough-In Dimensions
Unpacking
Electrical Installation
Grounding Requirements
3 & 4-Wire Connections
Installation
Replacement Parts

PAGE
2
2
2
2
3
4
4
4
5
5
6
6
7
7
8

P/N131661700 (O11O)

PRE-INSTALLATION

POWER SUPPLY CORD -The gas laundry center is equipped
with a 120 volt 3-wire power cord.

REQUIREMENTS

Tools and Materials Required for Installation:
1. Phillips head screwdriver.
2. Channel-lock adjustable pliers.
3. Carpenter's level.
4. Flat or straight blade screwdriven
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.16 cm) duct.
7. Vent hood.
8. Pipe thread sealer (Gas).
9. Ratchet with 3/8 inch (0.96 cm) socket.

NOTE: Do not under
any circumstances
remove grounding
prong from plug.

\

ELECTRICAL REQUIREMENTS
ELECTRICLaundry Center

Grounding Prong

Circuit- Individual 30 amp branch circuit fused with 30 amp
minimum time delay fuses or circuit breakers.

WATER SUPPLY REQUIREMENTS

POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60
Hz, Alternating Current.

Hot and cold water faucets MUST be installed within 42 inches
(106.68 cm) of your laundry center's water inlet. The faucets
MUST be 3/4 inch (1.9 cm) garden hose type so inlet hoses can
be connected. Water pressure MUST be between 10 and 120
pounds per square inch (maximum unbalance pressure, hot vs.
cold, 10 psi). Your water department can advise you of your
water pressure. The hot water temperature should be about
140 degrees E

POWER SUPPLYCORD KIT-The laundry center MUST employ
a 3-condutor power supply cord NEMA 10-30 type SRDTrated
at 240 volt AC minimum, 30 amp, with 3 open end spade lug
connectors with upturned ends or closed loop connector OR a
4-condutor power supply cord NEMA 14-30 type SRDTor ST
(as required) rated at 240 volt AC minimum, 30 amp, with 4
open end spade lug connectors with upturned ends or closed
loop connectors and marked for usewith clothes dryers. If being
installed in a manufactured (mobile) home, the laundrycenter
MUST employ a 4-condutor power supply cord NEMA 14- 30
type SRDTor ST (as required) rated at 240 volt AC minimum,
30 amp, with 4 open end spade lug connectors with upturned
ends or closed loop connectors and marked for use with clothes
dryers. See ELECTRICAL CONNECTIONS. (Canada - 4-wire
power supply cord is installed on laundry center.)

DRAIN REQUIREMENTS
1. Drain capable of eliminating 17 gals. per minute.
2. A standpipe diameter of 1-1/4 inches (3.18 cm) minimum.
3. The standpipe height above the floor should be:
Minimum height: 33 inches (83.82 cm)
Maximum height: 96 inches (244 cm)

OUTLET RECEPTACLE- NEMA 10-30R (3-wire) receptacle or
NEMA 14- 30R (4-wire) receptacle to be located so the power
supply cord is accessible when the laundry center is in an
installed position.

T
96"Max.
(244 cm)

-"T"33" Min.

__L
NEMA 10-30R

I

NEMA 14-30R

GAS Laundry Center

NOTE:For installations requiring a longer drain hose, have a
qualified technician install a longer hose PIN 131461201,
available from an authorized parts distributor. For drain
systems in the floor, install a siphon break kit, available
from your local hardware store.

I

CIRCUIT -individual 15 amp branch circuit fused with a 15 amp
maximum time delay fuse or circuit breaker.
POWER SUPPLY -3 wire, 120 volt single phase, 60 Hz,
Alternating Current,
2

EXHAUST

SYSTEM REQUIREMENTS

The maximum length ofthe exhaust system depends upon
the type of duct used, number of elbows and type of exhaust
hood,

Use only 4 inch (10.16 cm) diameter
(minimum) rigid or flexible
metal duct and approved
vent hood which has a swing-out
damper(s) that opens when the dryer is in operation.
When the
dryer stops, the damper(s) automatically
closes to prevent drafts
and the entrance of insects and rodents. To avoid restricting the
outlet,
maintain
a minimum
of 12 inches (38.5 cm) clearance
between

The maximum length for both rigid and flexible duct is shown
in the chart below.

the vent hood and the ground or any other obstruction.

EXHAUST

DUCT

EXHAUST

The following are specific requirements
for proper and safe operation of your laundry center,
Failure to follow these instructions can create excessive

LENGTHS

HOOD

TYPE

25"

Tums

drying times and fire hazards.

Louvered

Do not use plastic flexible duct to exhaust
the dryer, Excessivelint can build up inside the exhaust system
and create a fire hazard and restrict air flow, Restricted air flow
will increase drying times. If your present system is made up of
plastic duct or metal foil duct, replace it with a rigid or flexible
metal duct, Ensure the present duct is free of any lint
prior to installing laundry center dryer duct.

(6

MAXIMUM
LENGTH OF 4-INCH (10.2 CM)
DIAMETER RIGID METAL DUCT
0
1
2
3

56
46
34
32

tt
tt
tt
ft

(1707
(1402
(1036
(975

m)
m)
m)
m)

MAXIMUM
LENGTH
OF 4-INCH
DIAMETER
FLEXIBLE METAL

If the dryer is not exhausted outdoors, some
fine lint will be expelled into the laundry area, An accumulation
of lint in any area of the home can create a health and fire
hazard. The dryer exhaust system MUST be exhausted to
the outside of the dwelling!
Do not allow combustible materials (for

0
1
2
3

30
22
16
10

ft
ft
tt
tt

(914 m)
{67 m)
(488 m)
(30S m)

42
36
28
18

[t
tt
[t
ft

(128
(1097
(853
(548

m)
m)
m)
m)

(10.2 CM)
DUCT
22 ft (67 m)
14tt (427 m)
10 tt (305 m)
S tt (1 5 m)

The laundry center may be exhausted four (4) ways with
rear flush installation:

example: clothing,draperies/curtains, paper) to come in contact
with the exhaust system, The dryer MUST NOT be exhausted
into a chimney, a wall, a ceiling, or any concealed space of a
building which can accumulate lint, resulting in a fire hazard.

1 Straight back
2. Down (8 inch [20.32 cm[ length of 4 inch [10.16 cm]
rigid duct and 1 elbow down)
3. Left (8 inch [20.32 cm] length of 4 inch [10.16 cm]
rigid duct, 1 elbow down and 1 elbow left)
4. Right (8 inch [20,32 cm] length of 4 inch [10,16 cm]
rigid duct, 1 elbow down and 1 elbow right)

Do not exceed the length of duct pipe or
number of el bows allowed in the" EXHAUST DUCT LENGTHS"
chart. Lint can accumulate in the system, plugging the system
and creating a fire hazard, as well as increasing drying times.
Do not screen the exhaust ends of the vent
system, nor use any screws or rivets to assemble the exhaust
swstem, Lint can become caught in the screen, on the screws
or rivets, clogging the exhaust system and creating a fire hazard
as well as increasing drying times. Use an approved vent hood
to terminate the duct outdoors, and seal all joints with duct
tape. All male duct pipe fittings MUST be installed downstream
with the flow of air.

Toexhaust up, add an 11 inch (27,94 cm) length of standard
4 inch (10,16 cm) diameter duct and a 90 ° elbow. The unit
will be positioned about 4Y, inches (11.43 cm) away from
the wall (flush to wall exhausting may be done by going
below the dryer then sideways).
An exhaust hood positioned to line up with the dryer exhaust
can be installed directly through the outside wall, ]o exhaust
to the side or down, add an 8 inch (20.32 cm) length of
standard 4 inch (10,16 cm) diameter duct and a 90 ° elbow,

Explosion hazard. Do not install the laundry
center where gasoline or other flammables are kept or stored,if
the laundry center is installed in a garage, it must be a minimum
of 18 inches (45.7 cm) above the floor. Failure to do so can
result in death, explosion, fire or burns.
The exhaust system back pressure MUST not exceed 0,6 inches
(1.52 cm) of water column, measured with an inclined
manometer at the point the exhaust connects to the dryer,
The exhaust system should be inspected and cleaned a
minimum of every two years with normal usage. The more the
dryer is used, the more often you should check the exhaust
system and vent hood for proper operation.
3

GAS SUPPLY REQUIREMENTS

5, The following illustrations show minimum clearance
dimensions and air openings for proper operation in a recess
or closet installation.
0_N

1. Installation MUST conform with local codes, or in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 (latest edition) or in Canada, the
current AN/CGA B149.
2. The gas supply line should be of 1/2 inch (1.27 cm) pipe,
3. If codes allow, flexible metal tubing may be used to connect
your dryer to the gas supply line. The tubing MUST be
constructed of stainless steel or plastic-coated brass.
4. The gas supply line MUST have an individual shutoff valve.
5. A 1/8 inch (0,32 cm) N. R T. plugged tapping, accessible
for test gage connection, MUST be installed immediately
upstream of the gas supply connection to the dryer.
6. The dryer and its individual shutoff valve MUST be
disconnected from the gas supply piping system during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.45 kPa).
7. The dryer MUST be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.45 kPa).

LOCATION OF YOUR LAUNDRY

MOBILE HOME

INSTALLATION

1. Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting that
will not support combustion, Metal ducting must be 4
inches (10,16 cm) in diameter with no obstructions,
Rigid metal duct is preferred.
2, If dryer is exhausted through the floor and area beneath
the mobile home is enclosed, the exhaust system MUST
terminate outside the enclosure with the termination
securely fastened to the mobile home structure.
3, Refer to page 3 for other important venting requirements.

CENTER

DO NOT INSTALL YOUR LAUNDRY CENTER:
1, In an area exposed to dripping water or outside weather
conditions.
2, In an area where it will come in contact with curtains or
drapes.
3, On carpet, Floor MUST be solid with a maximum slope of 1
inch (2,54 cm).
INSTALLATION IN RECESSOR CLOSET
1, A laundry center installed in a bedroom, bathroom, recess
or closet, MUST be exhausted outdoors,
2, No other fuel burning appliance shall be installed in the
same closet as the Gas laundry center.
3, Your laundry center needs the space around it for proper
ventilation,
DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET
WITH A SOLID DOOR.
4, A minimum of 120 square inches (774,2 square cm) of
opening, equally divided at the top and bottom of the door,
is required. Air openings are required to be unobstructed
when a door is installed. A Iouvered door with equivalent
air openings for the full length of the door is acceptable,

4, When installing a gas dryer into a mobile home, a
provision must be made for outside make up air This
provision is to be not less than twice the area of the
dryer exhaust outlet.
5, Installation MUST conform to current Manufactured
Home Construction & Safety Standard (which is a
Federal Regulation Title 24 CFR-Part 32-80) or when
such standard isnot applicable, with American National
Standard for Mobile Homes. In Canada, the CSA Z240
is applicable,
The laundry center is designed under
ANSI Z 21.5.1 for HOME USE only.
Closet Door

4

ROUGH-IN

DIMENSIONS

4t_

2YzlN
(6 35 CM)

It--

1 7/8 iN
(476 CM)

J

GASSUPPLY
PiPE(REAR)

_1333

75 Y_IN
(19177 CM)

CM)
5Y41N

l

ELECTRICAL
CONNECTION

54 5/16 IN
(13795 CM)

O

WATER iNLETS

43 IN

_fO

4 13/16 iN

(REAR)

(12 22 CM)

43 IN
(109 22 CM)

_(

f
\__
I_
i,

(1O922 eM)
10441
7_41
NM)

361/16iN
(9160 CM)

1

29 7/16 iN
(7477 CM)

(REAR)
3Y_IN

(9 52 CM)
DRAIN OUTLET

hJ

hJ

27 IN

NOTE: If the laundry center is to be transported at a
later date, the tub blocking pad, shipping bolt, and
plastic spacer block should be retained.
PLASTICSPA(

u

30 13/16 IN
(7826 CM)
to al, up, ,N, ,L position,

Return laundry center
4, Remove:
(a) roam tub blocking pad,
(b) roam shipping blocks from rear of unit.
(c) tape from dryer door.
(d) foam dryer support pads.
(e) inlet hoses.
(f) enclosure package,
,

1, Using the four shipping carton corner posts (two on each
side), carefully lay the laundry center on its left side and
remove foam shipping base.
2, Using ratchet with 3/8 inch (0,96 cm) socket, remove
mechanism shipping bolt and plastic spacer block from
center of base.

u

I1_

(68 58CM)

UNPACKING

11 7/16 IN

(295 CM)

5, From the back of the washer, remove the wire shipping
clips securing the drain hose and power cord (if equipped).
Plastic clamps secure the drain hose to the right side of the
washer backsheet, These clamps form a standpipe to
prevent water syphoning. DO NOT REMOVE THESE
CLAMPS.
6, Carefully move the laundry center to within 4 feet (1,22 m)
of the final location to begin the installation,

MECHANI!
SHIPPING
BOLT
G CARTON CORNER POSTS

FOAM
SHIPPING
PAD

:)OWER CORD
(IF EQUIPPED)

DSE
5

ELECTRICAL INSTALLATION
ALL ELECTRICLaundry Centers
he following are specific requirements
fe electrical installation of your laundry
center. Failure to follow these instructions can create
electrical shock and/or a fire
hazard

For a permanently connected laundry center:
The laundry center MUST be connected to a grounded metal,
permanent wiring system; oran equipment grounding conductor
MUST be run with the circuit conductors and connected to the
equipment-grounding

terminal or lead on the appliance,

_T'_ L_;f-_tlt_ll_B

This
appliance
MUST
beproperly
grounded. Electrical shock can result if the laundry center is
not properly grounded, Follow the instructions in this manual
for proper grounding.
_Do

not use an extension cord with this

laundry center. Some extension cords are not designed to
withstand the amounts of electrical current this laundry center
utilizes and can melt, creating electrical shock and/or fire
hazard, Locate the laundry center within reach of the receptacle
for the length power cord to be purchased, allowing some
slack in the cord. Refer to the pre-installation requirements in
this manual for the proper power cord to be purchased.
_A
U,L. approved strain relief must be
installed onto power cord, If the strain relief is not attached,
the cord can be pulled out of the laundry center and can be cut
by any movement of the cord, resulting in electrical shock,
Do not use an aluminum wired receptacle
with a copper Wired power cord and plug (or vice versa). A
chemical reaction occurs between copper and aluminum and
can cause electrical shorts, The proper wiring and receptacle
is a copper wired power cord with a copper wired
receptacle OR aluminum wired power cord with an
aluminum wired receptacle,
NOTE: Laundry centers operating on a 208 volt power supply
will have longer drying times than laundry centers operating
on a 240 volt power supply.

GROUNDING

REQUIREMENTS

Non-Canadian ELECTRICLaundry Center
_

Improper connection

of the equipment

grounding conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
For a grounded, cord-connected laundry center:
1, The laundry center MUST be grounded, In the event of
malfunction or breakdown, grounding will reduce the risk
of electrical shock by a path of least resistance for electrical
current.
2, If your laundry center is equipped with a power supply cord
having an equipment-grounding conductor and a grounding
plug, the plug MUST be plugged into an appropriate, copper
wired receptacle that is properly installed and grounded in
accordance with all local codes and ordinances. If in doubt,
call a licensed electrician,
6

Canadian ELECTRICLaundry Center

_lmproper
connection of the equipment
grounding conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded,
For a grounded cord connected laundry center:
1, The laundry center MUST be grounded, In the event of
malfunction or breakdown, grounding will reduce the risk
of electrical shock by providing a path of least resistance
for the electrical current,
2, Since your laundry center is equipped with a power supply
cord having an equipment-grounding conductor and a
grounding plug, the plug MUST be plugged into an
appropriate outlet that is properly installed and grounded
in accordance with all codes and ordinances, If in doubt,
call a licensed electrician
ALL GAS Laundry Centers
1, The laundry center, when installed, MUST be electrically
grounded in accordance with local codes, or in the absence
of local codes, with the National Electrical Codes, ANSI/
NFPA (latest edition) or in Canada, CSA C22.1 Canadian
Electrical Code Part 1,
2. The laundry center is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong
receptacle, Do not cut or remove the grounding prong from
the plug,

ELECTRICAL CONNECTIONS
FOR A 3-WIRE SYSTEM

I

6, Attach the white (neutral) wire from the power cord and the
green ground wire from the appliance harness to the silvercolored center terminal on the terminal block. Tighten the
screw securely.

ELECTRICLaundry Center
Green Ground
Screw

1, Remove the screw securing the
terminal block access cover to the
rear panel and remove cover.
2, Install a U.L approved strain relief
connector in the entry hole on the
back panel.
3, Insert a NEMA 10-30 Type SRDI,
Ui. approved power cord
through the strain relief,
4, Attach the power cord neutral (central wire) conductor to
the silver colored center terminal on the terminal block,

/

Conductor
(Cord)

Green Ground
Wire

Silver Terminal

Terminal Block

"White
_Black

Tighten the screw securely.

7, Attach the red and black wires from the power cord to the
outer brass-colored terminals on the terminal block. Tighten
both screws securely.
8, Tighten the screws securing the cord restraint firmly against
the power cord,
9, Reinstall the terminal block access coven
INSTALLATION
1, Run some water from the hot and cold faucets to flush the
water lines and remove particles that might clog up the
water valve screens.
2, Check inlet hoses to ensure the rubber washers are installed
in each end,
3, Carefully connect the inlet hoses to the water valve (on the
left side of the washer cabinet), tic hten by hand, then tighten
another 2/3 turn with pliers,

5,Attach the remaining two power cord outer conductors to
the outer brasscolored terminals on the terminal block,Tighten
both screw securely,
&Tighten the screws securing the cord restraint against
the power cord,
7, Reinstall the terminal access cover

_DO
NOT CROSS THREAD OR OVERTIGHTEN
THESE CONNECTIONS.
4, Determine which water faucet is the HOT water faucet and
carefully connect the bottom inlet hose to the HOT water
faucet, tighten by hand, then tighten another 2/3 turn with
pliers, Carefully connect the top inlet hose to the COLD
water faucet, tighten by hand, then tighten another 2/3 turn
with pliers.

ELECTRICAL CONNECTIONS
FOR A 4-WIRE SYSTEM

I

ELECTRICLaundry Center

1, Remove the screw securing the
terminal block access cover to the
rear panel and remove cover.
2, Install a U.L approved strain relief
connector in the entry hole on the
back panel,
3, Remove the green neutral ground wire
from the green ground screw located above the termial
block,

DO NOT CROSS THREAD OR OVERTIGHTEN
ECTIONS. Turn the water on and check for leaks
at both connections,
5, Carefully move the laundry center to its final location,
6, ]o ensure the laundry center is level and solid on all four
legs, tilt the laundry center forward so the rear legs are
off the ground. Gently set the laundry center back down to
allow the rear legs to self adjust. Placea level on top of the
washer Check it side to side, then front to back. Screw the
front leveling legs up or down to ensure the laundry center
is resting solid on all four legs (no rocking of the laundry
center should exist).

4, Insert a NEMA 14-30 Type STor SRDT,U,L, approved power
cord through the strain relief,
5, Attach the green power cord ground wire to the cabinet
with the green ground screw

NOTE: Keep the leg extension at a minimum
excessive vibration.
7

to prevent

7,GASCONNECTION
(Gas laundry centers only)

10. Connect the exhaust duct to outside duct work, Use duct

a. Remove the shipping cap from gas pipe at the rear of the
dryer,
NOTE: DO NOT connect the laundry center to LR gas service
without converting the gas valve. An LR conversion kit (P/
N 5303937053) must be installed by a qualified gas
technician.

tape to seal all joints,
11. Plug the power cord into a grounded outlet,
NOTE: Check to ensure the power is off at a circuit breaker/
ruse box before plugging the power cord into an outlet,
12.T_
at a circuit breaker/fuse box.
Before operating the dryer, make sure
the dryer area _sclear and free from combustible materials,
gasoline, and other flammable vapors, Also see that nothing
(such as boxes, clothing, etc.) obstructs the flow of
combustion and ventilation air,
13. Reinstall the dryer front access panel.
14. Run the washer and dryer though a cycle, Check for proper
operation.
NOTE: On gas dryers, before the burner will light, it is
necessary for the gas line to be bled of air, If the
burner does not light within 45 seconds the first time
the dryer is turned on, the safety switch will shut
the burner off. If this happens, turn the timer to
"OFF" and wait 5 minutes before making another
attempt to light,
15. If your laundry center does not operate, please review the
"Avoid Service Checklist" located in your Owner's Guide
before calling for service.
16, Placethese instructions in a location near the laundry center
for future reference.

b. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved
pipe from the gas supply line to the 3/8 inch (0.96 cm) pipe
located on the back of the dryer, Use a 1/2 inch (1.27 cm) to
3/8 inch (0.96 cm) reducer for the connection. Apply an
approved thread sealerthat isresistant to the corrosive action
of liquefied gases on all pipe connections.
c. Open the shutoff valve in the gas supply line.
d. Test all connections by brushing on a soapy water solution.
NEVER TEST FOR GAS LEAKSWITH AN OPEN FLAME.
8. Form a " U " shape on the end of the drain hose with the
hose pointed toward the drain. Place the formed end in a
laundry tub or a standpipe and secure with a cable tie provided
in the enclosure package, WATER WILL SYPHON FROM
THE WASHER IF THE ABOVE INSTRUCTIONS ARE NOT
FOLLOWED,

NOTE: A wiring diagram is located behind the dryer front
access panel.

REPLACEMENT

PARTS

If replacement parts are needed for your laundry center, contact
the source where you purchased your laundry center.
I!!_IKI_,!_I
Destroy the carton, plastic bags, and metal
band after the laundry center is unpacked. Children might use
them for play Cartons covered with rugs, bedspreads, or plastic
sheets can become airtight chambers causing suffocation. Place
all materials in a garbage container or make materials
inaccessible to children,
_
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation, Verify proper operation after servicing.

9. Remove the two (2) screws securing the dryer front access
panel to the dryer cabinet. Lift the panel until the tabs can
be disengaged from the cabinet, Remove the panel and set
aside,

[he instructions in this manual and all other
this laundry center are not meant to
cover every possible condition and situation that may occur.
Good safe practice and caution MUST be applied when
installing, operating and maintaining any appliance.
Maximum benefits and enjoyment are achieved when all
the Safety and Operating instructions are understood and
practiced as a routine with your laundry tasks,

Access
anel
Screws

8



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 8
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Fri Apr 20 13:37:10 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu