READ BEFORE

iNSTALLiNG

For Slider Casement

UNiT

Air Conditioners

Carefully read the installation manual before beginning.
Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
Pay attention to danger and safety notices.
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may
be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To
prevent injury or strain, use proper lifting and carrying techniques when moving unit
Carefully inspect location where air conditioner will be installed, Be sure it will support the weight of the unit overan extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.

_, These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or
installation in a metal CASEMENT window. Modification may be necessary when installing in windows made
differently than those shown in these instructions.

Meeting

Electrical

Requirements

Electrical Shock and Personal Injury Hazard
= Electrical ground is required on this appliance.
o DO NOT ground to a gas line.
,_ If cold water pipe is interrupted by plastic, non-metallic gaskets, or other insulating materials, DO NOT use for
grounding.
= Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
® DO NOT modify power supply cord plug. If it does not fit outlet, have a proper outlet installed by a qualified
electrician.
o DO NOT have a fuse in the neutral or grounding
an electrical shock.

circuit. Afuse

in the neutral, or grounding

circuit could result in

o DO NOT use an extension cord with this appliance.
Failure to follow these instructions could result in electrical shock, serious injury, or death.
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES.
REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.

DO NOT, UNDER ANY CIRCUMSTANCES,

• If codes permit, and a separate grounding wire is used, it is recommended
that the grounding path is adequate and not interrupted
materials.

that a qualified electrician determine

by plastic, non-metallic

gaskets, or other insulating

2020213A1659

Receptacle
Wiring:
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is your responsibility
and adequate receptacle wiring, installed by a qualified electrician.

to provide proper

Electrical Requirements:
A 115 volt (103.5 minimum, 126.5 maximum), 60 Hertz, AC only, 15 ampere fused electrical supply is required. Atime
delay fuse or time delay circuit breaker is also required. A separate circuit, serving this appliance only, MUST be
)rovided.
Electrical Connection:
Electrical grounding is required on this appliance.

3-Prong Grounding
Type Wall Rece

Recommended
grounding
method:
For your personal safety, this appliance must be grounded.
This air conditioner includes a power supply cord with a
3-prong grounding plug. To minimize possible electrical shock
hazard:

3-Prong
Grounding plug

cord must be plugged into a matching 3-prong grounding type
wall receptacle.
must be grounded
Code (ANSI/NFPA
ordinances.

in accordance with National Electrical
70-latest version) and all local codes and

Grounding prong

If a matching 3-prong grounding type wall receptacle is not available,
it is the responsibility of the consumer to have a properly grounded
3-prong wall receptacle installed by a qualified electrician.

Power

Supply

(6 feet

long)

Cord
FIG.

Preparing

wood strip
mounted on

for installation

installation Tips
For wood-frame
casement

top of inner sill

!

Bottom Rail of
air conditioner
/;

windows:

It may be necessary to construct a frame, using at least
1" thick wood, with a 15-1/2" wide opening.
For brick or cement building construction:
It may be necessary to put a wood stool strip under air
conditioner, for mounting purposes as shown FIG. 2.

FIG. 2

Failure to adhere to the following precautions could result in personal injury and product damage.
Because this unit weighs about 60 to 80 pounds, it is recommended that you have someone help you when
installing your new unit, and that you both use proper lifting techniques. Inspect the condition of the window
where unit will be installed. Be sure it will support the weight of the unit.
• This appliance must be installed according to all applicable codes and ordinances.
,, Handle air conditioner with care. AVOID sharp metal fins on front and rear coils.
,_ Make sure your air conditioner does not fall during installation.
Do not use water collected in the unit for drinking purposes. It is not sanitary.
Tools Required
,_ Flat-head screwdriver
® Phillips-head

screwdriver

_, Carpenter's

level

Tape measure

® Fine tooth saw
• Electric or hand drill

,, DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED

_, Knife and scissors
Pencil

IN THESE INSTRUCTIONS,

H Make
sure
you
have
allthenecessary
parts.
Installation
kitcontents
(FIG.3):
No.
Hardware Qty. No.

orll

Hardware

Qty.

1

Platform

1

11

Screw #10 x 1" pan-head

2

2

Support brace

1

12

Screw #8 x 3/4" pan-head

6

3

Adjustment bolt

1

13

Screw #8 x 3/4" self-threading

7

4

Hex flange nut - 1/4

1

14

Window locking bracket

1

5

Track seal

1

15

Plastic window panel

1

6

Side channel seal

1

16

Side channel

7

Window sash seal

1

17

Screw_#8 x 3/8" truss head

10

8

Safety bracket

1

18

Panel frame/seal assembly

1

19

Support
bracket
(ForVinyi4:iiad
windows)

1

9

Screw #10 x 2-1/2" flat-head

2

10

Screw #10 x 1-3/4" flat-head

2

or17

2

Safety bracket
(For

Viny1431ad

windows)

• Use scale below to measure length of your screws. The scale will come in handy
when separating screws for installation.
IDENTIFY SCREWS
BY LENGTH

(13ram) (25ram)
1/2"
1"

(44ram)
1-3/4"

(63ram)
2-1/2"
FIG.4
1.571/2" _

m,;:d hm
3/8"
(10ram)
M

3/4"
(19ram)

1-1/2"

2"

(38ram)

(50ram)

Choose a proper sized window, as shown (FIG.4).
15-1/2" minimum width
16-1/4" maximum width (for casement windows)
21-1/2" minimum height (with window panel retainer)
20-5/16" minimum height (window panel retainer removed)
40" maximum height

16-114"
maximum
width
(casement
windows)

21-1/2"
minimum
height
40"
maximum
height

.........
2
-q
J

_FIG.5
• Height measurement must be of a clear opening above mounting platform.
In some cases, due to a variety of stop and track arrangements, the above
dimensions may vary slightly. If necessary, installation can be made by
alternating window jambs. (See Alternate Window Jamb Applications.)
a
Choose the proper window location.
Choose a window that allows the cooled air to flow freely and directly into
room(s) you wish to cool. Remember, it is difficult to move air around
corners. Also, choose a window that is within 6 feet of an electrical outlet
as shown (FIG.5). (See Meeting Electrical Requirements/Receptacle
wiring
needs,) Do not use an extension cord.

1

Installing

Unit

in a Sliding

Window:

FIG.8
Platform Assembly

n
Attach support brace to platform as shown (FIG.6). Use adjustment
bolt and hex flange nut to complete assembly. Choose slot and adjustment
bolt hole locations that will create a 45 degree angle between platform and
support brace. Try assembly in the window to determine if platform will rest
properly, and allow proper slope (3/16" lower on out side).

_-----_.
+ If you are planning to use a siding-protection board (see Step 8) on the
outside of your house, hold board in place when testing assembly in window.

n

1/4" (6ram) HEX
FLANGE NUT

8-11/16" inches

FIG.7

Measure, and lightly mark a line 8-11/16" from window jamb:

+ If any sash stop protrudes more than 1" from the side window jambs, the
8+11/16" measurement must be increased accordingly (FIG.7). Screen and
storm window frames may also require adjustments to the measurement.

_
Center platform assembly on the line with inside platform tab
pressed against inside edge of window track as shown (FIG.8A, FIG.8B).
Using the holes in the platform as a guide, mark and drill two 9/64" diameter
holes. Drill holes in either track or stool.
For vinyl-clad windows, you need to install the support bracket on the
window track before you install the platform. Follow the instructions below to
do that.
I. Place the support bracket on the window sill as shown (FIG.8C). Using the
holes in the support bracket as a guide, mark and drill two 1/8" diameter holes.
2. Follow Step 7 to applly the track seal on the room side of window track.
3. After applly the track seal, use two 3/8" screw (item 17) to fixing the support
bracket. Make sure the support bracket is level form side to side.
Proceed to Step 9 after you finish fixing the support bracket.

J

Center platform
assembly on the line
with platform tab pressed
against window track

Alternate screw location
(depending on the inner sill depth)
Platform tab FIG.8B

_Peel
off protective backing from track seal. Apply seal to room side
of window track (FIG .9). Center of seal strip should coincide with the line
marked in Step 5. The two screw holes drilled in Step 6 should be directly
above seal strip in the inner track.
_

Securely

attach a siding-protection

NOTE: Siding-protection

board to side of house (FIG.10).

window track

window seal

board should be long enough to span 2 wall studs.
FIG.10

FIG.SC
8-11/16" inches
i

FIG.9
Apply track seal
to window side
of track.

Iofhdoes_'_a
II

_

+

Alternate the screw
(depending on
the height of the sill)

_/_

bSiod_
_g-p rotecti o n

O
Place platform assembly, with platform tab against inside of window
track, and attach it to window jamb (FIG.11A). Use appropriate length
screws (Items 9-11 in preparing For Installation).
For Vinyl- Clad windows, place platform assembly, with platform tab
against insidh edge of the support bracket, and use two 3/8" screw (item 17)
to attache it to support bracket as shown (FIG.lIB).
_
Adjust platform assembly so that outside edge is 3/16" lower than
inside edge, as shown (FIG.11A & FIG.B). This ensures proper water drainage
from the air conditioner.
m
Level platform assembly from side-to-side.
Also, make sure window
track is level. Use leveling shims as necessary to ensure unit is level from
side-to-side.
_'_ Measure height of window opening from top of platform assembly as
shown (FIG. 12). Subtract 20-5/8". Mark this measurement on plastic window
panel, along the longer side.

Outside

edge is 3/16"

Put platform
tab against
inside of track
__

lower

than inside._

FIG.11B
Put platform tab

Outside edge is 3/16"

_
Clamp plastic window panel between a board and a work table, and
cut along cutting line with a fine tooth saw. Remove any burrs with a file.
_
Fasten side channels to the sides of the air conditioner using 3 screws
(Item 17) per channel as shown (FIG.13). Start with first screw at top of
channel. Make sure hook ends of channels face toward back of unit.
_
Slide plastic window panel into panel frame as shown (FIG.14), with
the smooth side to the room. Slide panel frame assembly into side channels
of the AC cabinet. Make sure plastic window panel is firmly enclosed on all
sides by the retainer grooves.
Panel frame

FIG.14

FIG.12

Plastic
window panel
_Cut
side channel seal into 2 equal lengths. Remove protective backing
and apply it to the rear side of cabinet side channels, starting just below panel
frame assembly (FIG. 15). Pinch off excess length so seal is even with the bottom
of the cabinet side channel.
into
remove front as shown (FIG.16)
t. Remove the two front retaining screws from the front frame.
2. Press firmly on each side of the metal case close to front, approximately 2/3 of the way down.
3. While pressing on the sides of the metal case, gently pull the front out and lift up to release it from the case.
4. Then release the electrical coupler plug.
NOTE: DO NOT push or pull air direction louvers.
_

Place air conditioner

in window

opening.

As shown (FIG.17), it should sit on platform assembly so that

window panel frame and cabinet side channels are against top and side window jambs.
FIG.15

FIG.16

FIG.17

channel seal
to side channels

/

side;\

just
Applybelow edg
of panel frame

Slide inner
Front ,_//_
Retaining/_
Screw
_

_/
_._._

window sash _]
firmly against _._1_
cabinet.

_ Slide
inner window

sash firmly against side of the cabinet. Make sure not to peel the seal strips from the window
track and cabinet side channels. If the panel frame does not fit snugly to the inner window sash, secure the panel frame
to the sash with #8 x 3/4" self-threading screws. Use the partially plugged holes in the panel frame. Drill 1/8" pilot
holes for the screws.
_Hook
the safety bracket over the base of the unit and fasten it to the front of the platform assembly (FIG. 18). Use
a #8-32 x 3/4" self-threading screw.
For Vinyl-Clad windows, use Item 20 (refer to page 3) to fasten the unit to the platform.
NOTE: The bracket prevents movement of the air conditioner (either in or out) after completing the installation.
I_!

Stuff the window

sash seal between the vertical sash and the window glass, as shown (FIG.19).

I_use
the window locking bracket to lock the inner window sash to the base of the outer window sash (FIG. 19).
Use one #8 x 3/4" screw, or #8-32 x 3/4" self-threading screw. (Drill 1/8" pilot hole).
_To
replace the front first reconnect the coupler plugs, make the exhaust control positioned through the front in
the proper location. Gently push the front into position on the cabinet. It should click into place. Then replace the
retaining screws that holds the panel in place. DO NOT push or pull the front panel louvers.
Insttall safety bracket
FIG.18

:lG.19

window sash
safety bracket
(choose the correct
bracket
according to your
window type)

Window
Iockinl
bracket

Alternate
Window
Jamb Applications
To install in windows having no flanges or wood stops on the top and side jambs, the channels and panel frame must
fit against a matching flange (or 1/16" max. thick angle) attached to the window jambs. FIG.20A shows this angle
installed. FIG.20B & FIG.20C show alternate treatments. On the sash side of the opening, the leading corner of the inner
sash becomes the flange. You can purchase the angle strip locally.

FIG.20A
Add angle to wood stop
Installing

the Unit in a Casement

FIG.20B
Add wood as shown

FIG.20C
Add 16- or 18- gage angle

Window
Platform

• Open the window the maximum amount to allow for clearance of the cabinet.
The crank handle should be removed to allow the platform to be fastened to
the jamb. if the window cannot open far enough (more than 15-1/2") for the
cabinet to clear the window, remove the window entirely by drilling out the
rivets. Bolts can serve as the pivots in the feature.
• To avoid crank handle and window clearance problems, the unit can be
installed in a stationary sash section. However, the horizontal mullion and
the 2 glass panels must be removed before installation.

_"X

Assembly

1/4" (6mm) HEX
FLANGE

_
Attach support brace to platform as shown (FIG.21). Use the adjustment bolt
and hex flange nut to complete the assembly. Choose the slot and adjustment bolt
hole location that will create a 45 degree angle between the platform and support
brace. Try the assembly in the window to determine if the platform will rest properly,
and allow the proper slope (3/16" lower on outside).

F IG.21

NUT

• If you are planning to use a siding-protection board (see Step 29) on the outside of your house, hold the board in
place when testing the assembly in the window.
I_
Drill a 9/64" diameter pilot hole in the window jamb an equal distance from each side of the jamb (FIG.22),
and 3/16" up from the window sill. If the hole coincides with the window lever slot in the jamb bottom, an additional
will have to be drilled through the platform edge and the window jamb to miss this slot.
_Peel
off the protective backing
bottom jamb as shown (FIG.23).
_
Screw the platform assembly
self-threading screw (FIG.24).
Equal distance from both sides

hole

from the track seal, and stick the seal to the window sill on the outside of the
to the window jamb through the pilot hole you drilled in Step 25. Use a #8 x 3/4"
Apply track seal to the outside
edge of the bottom window jamb.

Screw

Track seal
/

64" diameter
_/

pilot hole
FIG.22

FIG.23

FIG.24

I_
Adjust the platform assembly so that the rear of the air conditioner will be 3/16" lower than the front (tilted about
2 ° to 4 ° downward to the outside). After proper installation, condensate should not drain from the overflow drain hole
during normal use, correct the slope otherwise.

A projection below the base of the air conditioner will require the rear of the platform to be 7/16" lower than the
front to create the 3/16" slant from front to rear (FIG.25).
_
Securely attach a siding-protection
as shown (FIG.26). The siding-protection
Rear is at least I
7/16" lower than I

board to the side of the house where the platform assembly hit the house
board should be long enough to span 2 wall studs.
FIG.27
_
B
Fasten siding
protection board to

the house

siding.

FIG.26

_
Measure the height of the window opening from the top of the platform
assembly as shown (FIG.27). Subtract 20_5/8". Mark this measurement on the
plastic window panel, along the longer side.
{_1 Clamp the plastic window panel between a board and a work table, and
cut along the cutting line with a fine tooth saw. Remove any burrs with a file.
F_an

el frame

[_1_'1Fasten the side channels to the sides of the unit using three screws
(Item 17) per channel. Make sure hook ends of channels face toward the back
of unit.
_
Slide the plastic window panel into the panel frame with the smooth
side to the room. Slide the panel frame assembly into the side channels of
the air conditioner cabinet. Make sure the plastic window panel is firmly
enclosed on all sides by the retainer grooves (FIG.28).
Plastic

window

panel

[_]J Cut side channel seal into 2 equal lengths. Remove the protective backing and apply it to the rear side of the
cabinet side channels, starting just below the panel frame assembly. Pinch off excess length so the seal is even with
the bottom of the cabinet side channel (FIG.29).
_To
remove front as shown (FIG.30)
t. Remove the two front retaining screws from the front frame.
2. Press firmly on each side of the metal case close to the front, approximately 2/3 of the way down.
3. While pressing on the sides of the metal case, gently pull the front out and lift up to release it from the case.
4. Then release the electrical coupler plug.
NOTE: DO NOT push or pull air direction louvers.
[_
Place the air conditioner
in the window opening as shown (FIG.31). It should sit on the platform assembly
so that the window panel frame and the cabinet side channels are against the top and side window jambs. Side
channels should overlap side window jambs equally.
FIG.29

FIG.30

Apply side
channel
seal to side
channels
below edge of
panel frame.
grill two 9/64" diameter

f

/

F_

Front
Screw
Retaining

_-/_
1_ I_-_

y

pilot holes in the top window jamb in line with the partially plugged holes in the panel

frame. Secure the panel frame to the window jamb with two #8-32 x 3/4" self-threading
necessary, two screws may be used on the sides of the panel frame as well.

screws. If additional holding is

grill two screw-clearance
holes in the cabinet side channels (near bottom) and two 9/64" diameter pilot holes
in the side window jambs. Secure the cabinet side channels to the window jambs with two #8-32 x 3/4" self-threading
screws. When doing this, be careful not to twist the side channel seals with the screws.
NOTE: Inserting screws will prevent the air conditioner

from being pushed into the room.

_To
replace the front first reconnect the coupler plugs, make the exhaust control positioned through the front
in the proper location. Gently push the front into position on the cabinet. It should click into place. Then replace the
retaining screws that holds the panel in place.
Do not push against or pull upon the front panel louvers.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 8
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Wed Oct 08 07:04:38 2014
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu