Frigidaire KG7 User Manual To The 15136040 E079 454c 8422 406c6ac9b8fd
User Manual: Frigidaire KG7 to the manual
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
22/04/11 A40 Furnaces Philco KG7 Series Gas Furnace Features & Benefits • • • • • • • • • • • • • • • • • • • Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct vent (2 pipe) system 100% fired and tested: All units and each component are tested on the manufacturing line Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures long life 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings (60, 90, 120 and 180 seconds) 30 second post purge: Increases life of heat exchanger Hot surface igniter: Innovative application of an appliance igniter. Utilizes proven Smartlite® technology Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service High static blowers: All models equipped with high static blowers 90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil LP convertible: Simple burner orifice and regulator spring change for easy of convertibility Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes Integrated control board: Incorporates connections for electronic air clear and humidifier Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws Sealed vestibule: Reduces burner and inducer sound levels Extended flush jacket: Jacket provides an "appliance appearance" CSA certified design 115V, 60Hz. Gas connections are 1/2" NPT C & L are Energy Star rated WARRANTY ON PHILCO FURNACES Warranty Details: Lifetime Heat Exchanger and 10 years on all parts when product is registered, 1 year Heat Exchanger and 1 year parts when not registered 1 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first year of operation to the original owner Warranty Registration: Register your system within 60 days of installation Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 22/04/11 A40-1 Furnaces 92+ AFUE Single Stage Gas Furnace (High Efficiency) • • High efficiency blower kit maximize efficiencies Multi-speed direct drive blower designed to give a wide range of cooling capacities. Switches on PCB, provides ultra easy motor speed selection. Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Upflow / Horizontal 38,000 1/3 - 4 - PSC - 4.80 C6BAX24(C,U)A C6BAX30(C,U)A KG7SC038D23A 904639K 54,000 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B KG7SC054D24B 904640K 72.,000 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B KG7SC072D24B 904641K 72,000 1/2 - 4 - PSC - 7.50 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C KG7SC072D35C 904642K 90,000 1.0 - 4 - PSC - 13.75 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C KG7SC090D35C 904643K 108,000 1.0 - 4 - PSC - 13.75 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D KG7SC108D45D 904644K 120,000 1.0 - 4 - PSC - 13.75 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D KG7SC120D45D 904645K Downflow 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B KG7SL054D24B 904651K 72.,000 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B KG7SL072D24B 904652K 90,000 1.0 - 4 - PSC - 7.50 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C KG7SL090D35C 904653K 120,000 1.0 - 4 - PSC - 13.75 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D KG7SL120D45D 904654K 54,000 R410 Coil: (C=Cased, U=Uncased) PVC & CPVC Fittings Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 22/04/11 A40-2 Furnaces 95+ AFUE Two Stage Gas Furnace (High Efficiency) • • Energy efficient brushless DC (ECM) motor Control board has connections for twinning Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Fixed Speed Upflow / Horizontal 60,000 1/2 - FS - BLDC - 6.2 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B 80,000 3/4 - FS - BLDC - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C KG7TC080D35C 904728K 100,000 3/4 - FS - BLDC - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C KG7TC100D35C 904729K 120,000 1.0 - FS - BLDC - 11.7 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D KG7TC120D45D 904730K KG7TC060D24B 904727K Fixed Speed Downflow 60,000 1/2 - FS - BLDC - 6.2 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B KG7TL060D24B 904731K 80,000 3/4 - FS - BLDC - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C KG7TL080D35C 904732K 100,000 3/4 - FS - BLDC - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C KG7TL100D35C 904733K 120,000 1.0 - FS - BLDC - 11.7 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D KG7TL120D45D 904734K R410 Coil: (C=Cased, U=Uncased) PVC & CPVC Fittings Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 22/02/13 A41 Furnaces Frigidaire FG7 Series Gas Furnace Features & Benefits • • • • • • • • • • • • • • • • • • • • Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct vent (2 pipe) system 100% fired and tested: All units and each component are tested on the manufacturing line Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assure a long life 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings (60, 90, 120 and 180 seconds) 30 second post purge: Increases life of heat exchanger Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service High static blowers: All models equipped with high static blowers 90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil LP convertible: Simple burner orifice and regulator spring change for easy of convertibility Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes Integrated control board: Incorporates connections for electronic air clear and humidifier Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws Blower compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation Sealed vestibule: Reduces burner and inducer sound levels Rounded corner jacket: Provides an "appliance appearance" CSA certified design 115V, 60Hz. Gas connections are 1/2" NPT C & L are Energy Star rated WARRANTY ON FRIGIDAIRE FURNACES Warranty Details: Lifetime Heat Exchanger and 10 years on all parts when product is registered, 20 years Heat Exchanger and 5 year parts when not registered 10 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first 10 years when registered, 1 year when not registered Warranty Registration: Register your system within 60 days of installation Extended Warranty Protection: Ask your Davies Rep for specific details on labor protection plans Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 22/04/11 A42 Furnaces 92+ AFUE Single Stage Gas Furnace (High Efficiency) • • Multi-speed direct drive blower designed to give a wide range of cooling capacities Switches on PCB, provide ultra easy motor speed selection Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Upflow / Horizontal 1/3 - 4 - PSC - 4.80 C6BAX24(C,U)A C6BAX30(C,U)A FG7SC038D23A 904639F 54,000 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B FG7SC054D24B 904640F 72,000 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B FG7SC072D24B 904641F 72,000 1/2 - 4 - PSC - 7.50 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7SC072D35C 904642F 90,000 1.0 - 4 - PSC - 13.75 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7SC090D35C 904643F 108,000 1.0 - 4 - PSC - 13.75 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D FG7SC108D45D 904644F 120,000 1.0 - 4 - PSC - 13.75 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D FG7SC120D45D 904645F 38,000 Downflow 54,000 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B FG7SL054D24B 904651F 72,000 1/2 - 4 - PSC - 8.20 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B FG7SL072D24B 904652F 90,000 1.0 - 4 - PSC - 7.50 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7SL090D35C 904653F 120,000 1.0 - 4 - PSC - 13.75 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D FG7SL120D45D 904654F R410 Coil: (C=Cased, U=Uncased) PVC & CPVC Fittings Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 22/04/11 A43 Furnaces 95+ AFUE Two Stage Gas Furnace (High Efficiency) • • iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling Two stage inducer optimizes efficiency on first stage heat and reduces sound levels Input Btuh HP -Speed-Type-FLA R410 Coil Model Number Part Number Fixed Speed Upflow / Horizontal 60,000 1/2 - FS - BLDC - 6.2 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B FG7TC060D24B 904727F 80,000 3/4 - FS - BLDC - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7TC080D35C 904728F 100,000 3/4 - FS - BLDC - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7TC100D35C 904729F 120,000 1.0 - FS - BLDC - 11.7 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D FG7TC120D45D 904730F Variable Speed Upflow / Horizontal 60,000 1/2 - VS - 6.2 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B FG7TC060DVB 904735F 80,000 3/4 - VS - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7TC080DVC 904736F 100,000 3/4 - VS - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7TC0100DVC 904737F 120,000 1.0 - VS - 11.7 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D FG7TC120DVD 904738F R410 Coil: (C=Cased, U=Uncased) PVC & CPVC Fittings Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 22/04/11 A44 Furnaces 97+ AFUE iQ Drive® Modulating Gas Furnace (Ultra High Efficiency) • • • iQ Drive® Modulating Heating Operation Includes: - Modulating gas valve from 100% to 50% input in 5% increments - Time proportioning modulation down to 15% - Variable speed inducer and blower iQ Drive® thermostat provides modulation down to 15% and is required for furnace operation iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling Input Btuh HP -Speed-FLA R410 Coil Model Number Part Number Fully Modulating, Variable Speed Upflow / Horizontal 60,000 1/2 - Variable - 6.2 C6BAX24(C,U)B C6BAX30(C,U)B C6BAX35(C,U)B C6BAX36(C,U)B FG7MQ060DVB 904743F 80,000 3/4 - Variable - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7MQ080DVC 904744F 100,000 3/4 - Variable - 8.7 C6BAX36(C,U)C C6BAX37(C,U)C C6BAX42(C,U)C FG7MQ100DVC 904745F 120,000 1.0 - Variable - 11.7 C6BAX42(C,U)D C6BAX48(C,U)D C6BAX60(C,U)D FG7MQ120DVD 904746F R410 Coil: (C=Cased, U=Uncased) iQ Drive® Controller & Accessories • • • • • IMPORTANT: The iQ Drive® Furnace must be controlled by the iQ Drive® Controller. This Controller requires 18-22 gauge stranded wire with a grounded shield when connecting to furnace. • • • • Customizable programming options for every day, weekdays, weekends or individual days On-board diagnostics alert when service or maintenance is needed Smart recovery gradually adjusts indoor temperatures for greater comfort Senses humidity and has a dehumidification mode that removes moisture quickly Communicates to various components within the iQ Drive® System and serves as the main controller for an iQ Zone® System Auto changeover automatically switches the thermostat from heating to cooling No batteries required, settings are stored internally in the event of a power failure Two color backlight for easy viewing Energy saving features are customizable (temperature setbacks, heat pump/electric heat or furnace changeover) Description Part Number iQ Drive® Controller - Complete System Monitor & Controller 920621F Accessories Individually Shielded Wire, 30m (100') 2 Pair, 4 Conductor, 22 AWG Stranded (7x30) TC Conductors, 300V RMS 60ºC B8723 Optional Outdoor Sensor 920938 PVC & CPVC Fittings Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 31/12/10 A45 Furnaces Floor Registers - Plastic • • • • Sleek modern look with rounded corners and blades Durable plastic construction, will not rust Smooth, quiet damper adjustment for desired level of air flow Easy to install, maintenance free Description Brand Part Number 3"x10" Register - White Deflecto RF31003B 3"x10" Register - Taupe Deflecto RF31028B 3"x10" Register - Brown Deflecto RF31036B 4"x10" Register - White Deflecto RF41003B 4"x10" Register - Taupe Deflecto RF41028B 4"x10" Register - Brown Deflecto RF41036B Horizontal Conversion Kit for Frigidaire "G6" Gas Furnaces • For converting a 90+ upflow residential gas furnace to a horizontal left or horizontal right position Kit Includes Installation Instructions (#707796) 1/2" barbed fitting (#663841) 2" to 1/2" PVC reducer bushing (#663840) 2" PVC tee (#663115) Tube, drain hard "J" - 5" x 2" (#663763) Tube, soft - 10" (#663764) Tube, soft - 50" (#663765) Tube, high temp, grey - 17.5" (#263965) Vinyl cap - 5/8" (#663723) Vinyl cap - 1/2" (#663684) Hose clamps (2) - 7/8" dia. (#668914) Reducer - 3" to 2" (#663692) Brand Part Number Frigidaire 903568 Horizontal installation suspended in attic or crawl space Filter Rack • Davies Supply Group Ltd. Comes with door Calgary (800) 661-1346 (403) 244-2161 Filter Size Part Number 16" x 25" x 1" FR16251 20" x 25" x 1" FR20251 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 15/02/13 A45-1 Furnace Accessories LP Gas Conversion Kits For G6 & L1 Series Furnaces • • • Designed for Canadian installations. To convert a natural gas furnace to LP/Propane gas for altitudes between 0 to 4,500 feet above sea level, the main gas orifice must be replaced. For higher altitudes (between 2,000 & 4,500 feet above seal level) the input must be de-rated by 10%. This can be done by simply reducing the manifold pressure without changing the gas orifices. Use on standard & slow opening models only Not for use with step regulator valves Application Brand Part Number For use with G6 & L1 series gas furnaces using a Honeywell Gas Valve Frigidaire 904091A For G7 Series Furnaces • • Designed for Canadian installations to convert a natural gas furnace to LP/Propane gas. Used for altitudes between 0 to 4,500 feet above sea level For altitudes between 0 and 1,999 feet, only the orifice needs to be changed. For altitudes between 2,000 and 4,500 feet, both the orifice and the regulator pressure need to be changed. Application Brand Part Number For use with G7 series gas furnaces using a Honeywell Gas Valve Frigidaire 904915 Application Brand Part Number For use with G7MQ series gas furnaces Frigidaire 904950 For G7MQ Modulating Furnaces Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 15/02/13 A45-2 Furnaces This Page Left Intentionally Blank Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 14/12/12 A45-3 Furnaces Flue Gas Venting System - System 636™ PVC • • • Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65oC or less Complete system fully certified to ULC S636 White pipe with unique blue certification markings made to SCH 40 dimensions Description Case Part Number Concentric Vent Kits • These "pipe-in-pipe" kits allow for both exhaust and intake pipes to penetrate the roof or side wall through only one hole and are 2" Concentric Vent Termination Kit (no vent screen) 3 196005 certified with mechanically fastened rain caps • Screw/bolt assembly (included) for mechanically fastening the rain 2" Wall Termination Kit (no vent screen) 1 081216 cap can be easily removed for cleaning or maintenance Wall Termination Kits 2" x 10' Pipe (Straight End) 10 194000 • For a traditional vent style, IPEX’s PVC Wall Termination Vent Kits 2" Coupling (HubxHub) 70 196352 require only two small wall penetrations for intake and exhaust. • Kits include a white finishing plate with a self sealing foam back 110 2" 45o Elbow (HubxHub) 196242 that can be screwed to the exterior wall. 2" 90o Street Elbow (SPxHub) 60 196232 Testing Plug & Bushing Kit • Allows an inline access point for flue monitoring using fully certified 55 2" 90o Long Elbow (HubxHub) 196122 System 636 components. The kit consists of a 2" x 1/2" reducer bushing (Spig x FPT) and a removable 1/2" MPT plug. 2" 90o Extra Long Elbow (HubxHub) 40 196022 • May be installed in new installations or added to existing lines 2" Sanitary Tee (HubxHubxHub) 35 196082 when monitoring is required • Bushing must be inserted in a 2" fitting socket 3" Flue Gas Venting System • May be used on vent lines in any diameter 3" Concentric Vent Termination Kit (no vent screen) 3 196006 • Certified for use only on IPEX System 636 flue gas vent lines. 2" Flue Gas Venting System 3" Wall Termination Kit (no vent screen) 1 081219 3" x 10' Pipe (Straight End) 10 194001 3" Coupling (HubxHub) 60 196353 3" 45o Elbow (HubxHub) 25 196243 o 15 196233 o 23 196123 o 3" 90 Extra Long Elbow (HubxHub) 15 196023 3" Sanitary Tee (HubxHubxHub) 17 196083 3" 90 Street Elbow (SPxHub) 3" 90 Long Elbow (HubxHub) Concentric Vent Kit Wall Termination Kit Adapters & Other Components 3" x 2" Increaser Coupling (HubxHub) 45 196364 3" x 2" Reducer Tee (HubxHubxHub) 10 196822 2" x 1 1/2" Reducer Bushing (SPxHub) Used with #196278 80 196282 1 1/2" x 1/2" Reducer Busing (SPxHose Barb) 80 196278 2" Testing Plug & Bushing Kit (SPxPlug) 10 196143 PVC Cement, Low VOC (1 pint/473ml) 12 196040 PVC Cement, Low VOC (1 quart/946ml) 12 196041 Transition Cement - To ABS Only (1 pint/473ml) 12 196044 Testing Plug & Bushing Kit Cement Primer Primer should be used when installing System636 products at temperatures below 0oC PVC/CPVC Purple Primer, Low VOC (1 pint/473ml) 12 196042 PVC/CPVC Clear Primer, Low VOC (1 pint/473ml) 12 196017 PVC/CPVC Purple Primer, Low VOC (1qt/946ml) 12 196043 NOTES: 1. Do Not interchange pipe, fittings or chemicals from different BH vent manufactures. Doing so will void System636™ product certification and warranty. 2. Contractors must check local codes for proper venting Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 14/12/12 A45-4 Furnaces Condensate Water Neutralizer Kit For High Efficient Gas Furnaces • Inline cartridge that will raise or neutralize the pH level of the condensate water Limestone neutralizer material should be changed yearly • Description Includes Part Number 2" Inline cartridge 1/2" ID vinyl tubing, hose clamps & mounting ties 902377 J Hooks (Furnace Venting Accessory) Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Description Part Number 2" x 7 1/2" DWV Swiveling J Hook (Plastic) 515-J2000 3" x 7 1/2" DWV Swiveling J Hook (Plastic) 515-J3000 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 11/06/10 A45-5 Furnaces Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces • • • • • • • • WARNING Not for use with Model Numbers: *G6RK096-12B & *GF1RK096-12B 904231 kit fits all G6/L1 series gas furnaces with an "A" width cabinet. May be configured for air conditioning/heat pump airflows from 1 1/2 to 3 tons nominal capacity. 904075 kit fits all G6 (RA,RC,RK&RL) series gas furnaces with "B" & "C" width cabinets. May be field configured for air conditioning/ heat pump airflows from 2 to 5 tons nominal capacity. Designed to maximize system efficiencies, improve air quality and reduce sound levels Air conditioning and heat pump efficiencies up to 16 SEER and 8.5 HSPF ECM (electronically commutated motor) variable speed DC motor allows for 12 selected cooling airflows and 8 heating airflows to match any applications Extra low speed for "fan only" operation Extra quiet and smooth blower on and off cycles Warranty: Carries the balance of original equipment warranty Description Part Number Fits "A" Width Cabinets for G6 & L1 series 904231 Fits "B" & "C" Width Cabinets for G6: RA,RC,RK,RL series (not suitable for "B" cabinet 1200 CFM applications) 904075 Specifications 904231 904075 Nominal Blower Size 10" x 6" 11" x 10" Maximum Motor HP 1/2 3/4 Programmable Variable Speed Programmable Variable Speed Cooling CFM Range* 720 to 1240 720 to 1870 Heating Airflow Range* 550 to 1215 720 to 1800 Motor Type * Airflow is held constant regardless of external static pressure within the HP and RPM limits of the motor Variable Speed Motor Tester - TECMate PRO™ • Designed to assist field service technicians by troubleshooting GE ECM 2.3 motors independently of the HVAC system Description Part Number TECMate Pro™ Variable Speed Motor Tester 904232 Twinning Kit For G7 Single Stage Gas Furnaces • • Davies Supply Group Ltd. Provides the capability to combine the operation of two single stage gas furnaces with PSC motors (not for use with 2 stage, modulating or variable speed blower models) Twinning function not backwards compatible with furnaces manufactured prior to June 2009 Description Part Number G7 Twinning Kit For Single Stage Gas Furnaces Manufactured After June 2009 920919 Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 06/09/13 A45-6 Furnaces This Page Left Intentionally Blank Davies Supply Group Ltd. Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 18/02/11 A45-7 Furnaces Oil-Fired Forced Air Furnaces With Burner • • • • • • • • 80+ AFUE Warranty: Limited lifetime on 14 gauge heat exchanger; 1 year parts LFR Models: Chamber-less unit is designed for compact installations requiring front or rear flue. The unit is approved for chimney or balanced flue venting and is ideal for electric conversions. The large filter rack can be placed on either side, bottom or rear LFR-VSM Models: With the Newmac Ultratech™ Motor Control. This system incorporates the furnace, control board, motor & blower. The 24VAC powered board uses a standard external HVAC transformer, is air conditioning ready and has LED indication and diagnostic output. NLF Model: For traditional replacement or new home construction requiring front flue NL2 Model: For traditional replacement or new home construction requiring rear flue NH3 Model: Vestibuled cabinet is approved for closet clearances All Pre & Post Purge Burners can be used with a Sealed Venting System (SVS). This system allows direct venting without chimneys. Required for installation: Sealed Venting Unit, Oil Flex Vent & Air Duct. Description Flue Btuh Output AC Rating (tons) Highboy Front / Rear 81,000 Highboy Front / Rear Highboy Direct Drive Blower Motor Burner Brand Part Number (Model Number) 4 F3 Riello Newmac 8010050-3* (LFR) 1/3 4 Beckett AFG Newmac 8010050-3B* (LFR80) 3 1/3 4 Beckett AFG Pre & Post Purge Newmac 8010050-3BP* (LFR) 81,000 3 1/3 Variable Speed Beckett AFG Newmac 8010081-3B* (LFR-VSM) Front / Rear 81,000 3 1/3 Variable Speed Beckett AFG Pre & Post Purge Newmac 8010081-3BP* (LFR-VSM) Lowboy Front 118,000 3.5 1/2 4 Beckett AFG Newmac 8010033DD-3B (NLF118) Lowboy Rear 77,000 3.5 1/2 4 Beckett AFG Newmac 8010027DD-3B* (NL2) Highboy Top 101,000 3 1/2 4 Beckett AFG Newmac 5010035 (NH3-101) HP Speed 3 1/3 81,000 3 Front / Rear 81,000 Highboy Front / Rear Highboy * Energy Star Rated Davies also stocks a selection of Beckett Burners. Call Davies Pros On Controls for proper application. 8010050-3B (LFR) 5010035 (NH3) Replacement Parts For 8010050-3B (LFR80) Furnace With Beckett AFG Burner Description Hago Nozzles Blower Unit (less Motor) Davies Supply Group Ltd. Specifications Part Number Capacity (USgal/hr): 0.50 Spray Angle: 45° - B 21566108 Capacity (USgal/hr): 0.55 Spray Angle: 45° - B 21566109 Bore: 1/2" Fan: 10" dia. Rotation: CW 2040116T Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433 15/01/10 A45-8 Furnaces Combination Oil/Gas & Wood Furnace With Beckett AFG Burner • • • • • • • • Separate combustion chamber for oil/gas Extra large brick lined firebox Pre-heated combustion air is introduced by a thermostatically controlled draft system Disposable air filters Warranty: 10 year limited on the heat exchanger CL85/95 Model: Automatic switching from wood to oil CL86/96C Model: Automatic switching from wood to oil, separate thermostats & large fire door. Burns wood without grates for better control and efficiency. CL86/96G Model (Wood/Oil/Coal): Where wood or coal is available, this model gives the ultimate conservation choice. Large firebox and firedoor with shaker grates for coal. CFM Btuh Output Blower Motor Brand Part Number (Model Number) 900/1000 82,000/94,000 1/3 HP Newmac 8010012-2B (CL85/95) 1200/1200 86,000/ 96,000 1/3 HP Newmac 8010015-2B (CL86/96C) 1200/1200 86,000/ 96,000 1/3 HP Newmac 8010014-2B (CL86/96G) Wood Only Furnaces • • 8010024G Davies Supply Group Ltd. WA0 Model: Is a wood add-on furnace designed for operation in conjunction with an existing residential oil furnace system with a firing rate of .75 gph to 1.10 gph. 10 year limited warranty. WB100 Model: Can be used alone or in conjunction with an existing residential system. 10 year limited warranty on the heat exchanger. CFM Btuh Output Blower Motor Brand Part Number (Model Number) 1200 100,000 - Newmac 8010024G (WA0) 1200 100,000 1/2 HP Newmac 8010001 (WB100) 8010001 Calgary (800) 661-1346 (403) 244-2161 Lethbridge (877) 595-7707 (403) 381-7707 Saskatoon (877) 355-3377 (306) 933-2433
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Create Date : 2013:09:05 11:19:19-06:00 Modify Date : 2013:09:05 11:19:19-06:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Creator : Title : Document ID : uuid:d4c7be4d-a23b-4448-8013-1ededf742f85 Instance ID : uuid:959b597b-5d5f-4ac0-8451-dfaa12d74418 Page Count : 16EXIF Metadata provided by EXIF.tools