User Manual

Model: FSL200 Laser Fume Extractor

WWW.FSLASER.COM

1

1.

Product Overview

This high quality fume extractor featuring low noise brushless motor
technology is designed for capturing dust particles and removing odors
when cutting or engraving with the Full Spectrum Laser line of laser
cutters. Use only OEM replacement filters from Full Spectrum Laser in
this machine to maintain top performance and warranty.

2.

Unpacking Inspection

Please check carefully to ensure that the following listed parts are
included. If there are any missing or damaged items, please contact
customer service.
Name of Parts

Qty

Remarks

Main Unit
Power Cord

1
1

4” Hose

1

Top Pre­Filter
HEPA Filter
Cartridge
Activated Carbon
Lower Filter
Cartridges

1

Installed.

1

Installed in main unit

4

Installed in main unit

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

2

3.

Unit Components

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

3

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

4

4.

Specifications
Model​
FSL200 Specifications
​

Air Inlet Size

4” duct

Input Voltage

AC110V

Maximum Power
Noise

<70dB

Length of Duct
Typical Flow Rate
Dimensions of Main Unit
Weight

5.

450W

Ø100mmx3m
295 CFM
21.5” ×16.5” × 36.25”
132 lbs

Installation & Use Instructions
The FSL200 fume extractor features 2 separated
compartments: a top compartment containing the Top Pre­filter
to trap large particles and a bottom compartment containing the
HEPA and Activated Carbon filter cartridges.

5.1

Maintenance of Top Pre­filter and Top Compartment
Air flows from the top air inlet downward through through the
top compartment containing the Top Pre­filter down into the
bottom compartment. Most of the large particles are trapped in
the upper compartment and it must be cleaned regularly. Use
the glass window to check for contaminants. Follow the steps
below to clean and maintain the inlet box when contaminants
are observed:

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

5
1. Pull the twist lock upward, and rotate clockwise to the
"OPEN" position to open the top compartment.
2. Clean or replace the Top Pre­filter.
3. Vacuum the inside of the top compartment to remove
any accumulated particles.
The top compartment should be cleaned periodically (at least
weekly) to prevent premature clogging of the filtering system.
5.2

Lower Filter Compartment
1. The bottom compartment contains 1x HEPA Filter and
4x Activated Carbon Filter cartridges.
2. Pull the two twist locks upward and rotate clockwise to
the "OPEN" position to open the front gate.
3. Grasp the handle on the top cartridge and pull out each
of the filter elements one by one.
4. After replacement, put the elements back in sequence
from bottom to top layer by layer.

5.3

Suction Duct Hose Installation
Remove the hose from the package, and attach one end of the
top 4” air inlet duct of the machine and the other end to your
Full Spectrum Laser machine’s outlet duct. Optionally you may
connect another hose (not included) to the bottom air outlet port
to vent the air outside. It is not normally not necessary to vent
the air outside.

Do not introduce a bend radius of more than 10” on the hose.
5.4
Machine Operating Instructions
Plug in and check if the power plug is properly fit into the socket.
Turn on the power switch.

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

6

5.5

Control Panel Button Functions

On/Off Button
Pressing the On/Off button on the control panel should cause the
machine to start running and the orange light on the machine control
panel should turn ON. Pressing the power button again should cause
the machine to stop running and the orange indicator light on the
machine control panel should turn OFF.
Flow+ Button
Press this button when the machine is running to increase the fan
speed, the number on digital display increases in multiples of 10, the
maximum number is 100 which means the machine is running in full
speed.
Flow­ Button
Press this button when the machine is running, the number on digital
display decreases in multiples of 10.
Proper Fan Speed

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

7
The fan speed should be set according to the actual requirements to
remove all smoke without creating too much of a vacuum. During laser
cutting, the laser machine should not fill up with smoke. If there is
lingering smoke during cutting increase the fan speed. Too high a
setting may cause the work piece to lift up and be pulled toward the
vacuum created. In addition, too high a fan speed
increases the power consumption as well as the noise level.
Time Set Button
While the machine is running, press the Timer Set button, the digital
display will show HXXX. Then press the Flow+/Flow­ buttons to adjust
the shutdown timing. XXX represents the timer countdown in hours
with a maximum of 300 hours and minimum of 1 hour. After you are
satisfied with the setting, press the Timer Set button again and the
digital display will show HXXX and start the countdown timer. For
example, H005 represents that the machine will shut down
automatically in 5 hours. This function is useful at the end of the day
when you turn the laser off but still want to keep cleaning any smell
residues that may remain inside the machine.
Ok/Setting Button
If the machine is in alarm status and buzzer sounds, press the
Ok/Setting button to turn OFF the alarm. If the machine is not in alarm
status, press the Confirm/Set button to check the total working hours of
the machine.

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

8

6.

Troubleshooting
Make sure the power is switched off and unplugged before
inspecting or repairing the machine!

Problem 1​
: The machine still works, but the air flow is very weak
and suction power is greatly reduced.
Cause​
:
Air Inlet is blocked or foreign body exists inside the duct.
The filter becomes saturated and hence gets blocked
and gives an alarm. Usually only the pre­filter gets
clogged quickly with large particles and needs to be
vacuumed or replaced.
Solution:
Turn off the power and open the top cover. Check if
there is any foreign objects blocking the air inlet. Then
check if the air vent is blocked or not. If the suction
power of the empty­loaded machine is normal, it means
the filter needs to be replaced.
Problem 2​
: The machine shuts down automatically after it is just
started. Even if you restart the machine, the same
problem happens again.
Cause:
The air flow through the machine is obstructed. As a
result, the starting current of the fan becomes very high,
hence the machine shuts down automatically for self
protection.
Solution:
Turn off the power and open the top cover. Check if
there is any obstructions in the air inlet or replace filters.
Problem 3​
: Power switch is ON, but machine does not run and the
power indicator does not light up.
Cause:
The fuse might be bad.
Solution:
The fuse needs to be replaced. Pop the fuse out from
the power socket using a flat head screwdriver and
replace.

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

9

If the problem remains after these inspections and maintenance
are performed, please contact customer service.

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

10

7.

Filter Use & Maintenance
This product has consumable replacement filters. They need to
be cleaned or replaced periodically to ensure proper operation.

8.

1.

Top Pre­filter
Place the Pre­filter at the bottom of the top
compartment. When the accumulated dust on the
Pre­filter is over 70% coverage and cannot be cleaned
anymore and must be replaced with a new one.

2.

Activated Carbon Filter Cartridges
Load 4x Activated Carbon Filter Cartridges into the
lower compartment. The cartridges are marked with an
arrow in the direction of airflow. In the FSL200 these
cartridges should be loaded with the arrow facing down.
If there is good airflow but the odors are not removed,
the Activated Carbon Filter is consumed and must be
replaced.

3.

Bottom HEPA Filter Cartridge
Load the HEPA Filter Cartridge with the arrow pointing
down on top of the 4x activated carbon filter cartridges.
It should be immediately cleaned off by vacuuming
when any accumulated dust affects the suction power.
When cleaning does not help replace the Middle HEPA
Filter with a new one.

Replacement Parts
Name

Top Pre­filter

Remarks

Pictures

Contained in Top
Compartment. Filters
large particles.
Replace or clean
weekly.

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

11

Lower HEPA Filter

Lower Activated
Carbon Filter
Cartridges

9.

Contained in the lower
Compartment. Placed
on top of Activated
Carbon Cartridges.
Removes small
particles.
Removes odors.

Important Use Considerations
While using the machine, the ambient temperature range of the
gas and the dust which is sucked into the air inlet should be
within the range 15­60ºC. Never use the machine when the
temperature is higher or lower than this temperature range.
When using the machine,the humidity of the gas and the dust
sucked into the air inlet should be between the range of
40%­80%. If the humidity is excessively high, the activated
carbon filter element will become rapidly saturated with water
and consumed.
Do not use this machine without all filter elements
because the fumes or the dust particles may be sucked into the
air blower and the control system causing damage. Any
operation without all filter elements installed is not covered
under warranty. Use only OEM replacement filter elements
from Full Spectrum Laser.
Do not continue to use the machine when the HEPA Filter
Cartridge or the Pre­Filter is clogged as this will increase motor
wear and shorten the service life of the machine. Please clean
and/or replace the filter elements regularly to ensure proper
machine operation.

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A

12
The warranty will not cover any losses or damage that may be
incurred by the user if instructions are not followed.

10.

Contact Information
Full Spectrum Laser LLC
6216 S Sandhill Rd, Las Vegas, NV 89120
Tel: (702) 802­3100
Fax: (702) 987­0150
http://fslaser.com/Support

Full Spectrum Laser ­ FSL200 ­ User Manual, 2016, Rev.A



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 13
XMP Toolkit                     : DynaPDF 3.0.50.151, http://www.dynaforms.com
Producer                        : RAD PDF 2.33.1.1 - http://www.radpdf.com
Create Date                     : 2016:03:16 11:07:36-08:00
Creator Tool                    : RAD PDF
Metadata Date                   : 2016:03:16 11:08:29-08:00
Modify Date                     : 2016:03:16 11:08:29-08:00
Document ID                     : uuid:1e355120-eff5-3e02-872e-e23c50e394af
Version ID                      : 1
Rendition Class                 : default
Creator                         : RAD PDF
Rad Pdf Custom Data             : pdfescape.com-open-228E2B2B17246A59EFE217486F3D35D90A506B40BD9C026D
EXIF Metadata provided by EXIF.tools

Navigation menu