Fudakang NC100 Infrared Thermometer User Manual NC100 UserManual 171019

Fudakang Industrial Co., LTD Infrared Thermometer NC100 UserManual 171019

Users Manual

Download: Fudakang NC100 Infrared Thermometer User Manual NC100 UserManual 171019
Mirror Download [FCC.gov]Fudakang NC100 Infrared Thermometer User Manual NC100 UserManual 171019
Document ID3724851
Application IDIL/zRQbRD5RGdB6zW72FSg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize178.6kB (2232488 bits)
Date Submitted2018-01-23 00:00:00
Date Available2018-07-23 00:00:00
Creation Date2017-10-19 17:43:55
Producing SoftwareAdobe PDF library 15.00
Document Lastmod2018-01-23 11:22:41
Document TitleNC100_UserManual_171019
Document CreatorAdobe Illustrator CC 2017 (Macintosh)(Infix Pro)

NC100
NC100 Bluetooth Non-Contact Infrared Thermometer
User Manual
Dear NC100 Owner:
Thank you for purchasing the NC100 Bluetooth Non-Contact
Infrared Thermometer. Please read this instruction manual first so
you can use this thermometer safely and correctly. Please keep this
instruction manual for future reference. This innovative medical
device uses advanced infrared (IR) technology to measure
temperature instantly and accurately on the forehead or object.
IMPORTANT SAFETY INSTRUCTIONS READ BEFORE USE
The following basic safety precautions should always be taken.
1. Close supervision is necessary when the thermometer is used by,
on, or near children, handicapped persons or invalids.
2. Use the thermometer only for the intended use described in this
manual.
3. Do not use the thermometer if it is not working properly, or if it
has suffered any damage.
KEEP THESE INSTRUCTIONS IN A SAFE PLACE
03
Table of Content
BEFORE YOU BEGIN
05
05
Intended Use
How does it work
06
06
Highlighted Features
06
Package Contents
Meter Overview
07
07
Display Screen
Display Mode
08
08
Select the Temperature Unit
09
Replacing the Battery
10
Setting the Thermometer
DETAILED INFORMATION
About Normal Body Temperature and Fever
PERFORM THE TEST
Using the Device
As a Body Measurement Thermometer
As an Object Measurement Thermometer
METER MEMORY
Recalling the Memory
MAINTENANCE
Care and Cleaning
SYSTEM TROUBLESHOOTING
Measurement Result
Troubleshooting
SYMBOL INFORMATION
SPECIFICATIONS
STATEMENTS AND DECLARATIONS
DISPOSAL
REFERENCE STANDARDS
WARRANTY
04
05
Cautions and Warnings
Restrictions of Use
10
11
11
12
12
12
14
15
15
16
16
17
17
18
19
20
21
23
24
25
BEFORE YOU BEGIN
Cautions and Warnings
˙As with any thermometer, proper technique is crucial to
obtaining accurate temperature readings. Please read this
manual thoroughly and carefully before using.
˙Always operate the thermometer in an operating temperature
range 10°C to 40°C (50°F to 104°F), and relative humidity less
than 80%.
˙Always store the thermometer in a cool and dry place -25°C to
55°C (-13°F to 131°F) and relative humidity less than 95%.
˙Avoid direct sunlight.
˙Avoid dropping the thermometer, if it happens and you think
the thermometer may be damaged, please contact customer
services immediately.
˙Do not touch the lens.
˙Do not disassemble the thermometer.
˙Basic safety precautions should always be observed, especially
when the thermometer is used on or near children and disabled
persons.
˙This thermometer is not intended to substitute for a consulta-
tion with your physician.
˙This thermometer and the subject must remain in a stable
environment for at least 30 minutes before measuring the
temperature.
˙When the measured temperature falls within the fever tempera-
ture range of ≥37.8°C (100°F) and <43°C (109.4°F), as indicated
by the red LCD display, please consult with your physician
immediately.
Restrictions of Use
This thermometer is clinically proven to produce accurate
temperature measurements. However, please be advised that the
accuracy cannot be ensured when the thermometer is not clean.
Check that the probe is clean before taking a measurement.
05
Intended Use
NC100 Bluetooth Non-Contact Infrared Thermometer is intended
for the intermittent measurement and monitoring of human body
temperature from forehead measurement at home. A control
measurement using a conventional thermometer is recommended
in the following cases:
1. If the reading is surprisingly low,
2. For new-born infants up to 100 days old,
3. For children under three years of age who have a weakened
immune system or who react unusually in the presence or
absence of fever.
How Does It Work
The thermometer measures the infrared heat generated by the
surface of the skin over the vessel and its surrounding tissue. The
thermometer then converts it into a temperature value.
NOTE:
The thermometer does not emit any infrared signal.
Highlighted Features
˙Non-contact measurement that does not require probe cover,
thereby saving cost of replacement.
˙Automatically power off if left idle for 60 seconds.
˙Memory function allows you to recall previous forehead results
up to 32 previous results.
˙Easy to read LCD with blue and red backlight in a dark environ-
ment.
˙Color visible indication of alarm (red) and measurement in
progress (blue).
˙Measurement within 5 cm.
06
Package Content
Thermometer
1.5 V AAA
Silicone
Alkaline
Dust Cover batteries x 2
User Manual
Meter Overview
Front view
Back view
1. Display Screen
2. Setting Button
3. Power Button
4. Measure / Memory Button
5. Battery Cover
6. Light Indicator
7. Sensor Probe
07
Display Mode
1. Low battery indicator
2. Object temperature indicator
3. Temperature reading
4. Date
5. Memory mode
6. Body temperature indicator
7. Temperature unit
8. Time
Display Mode
Press setting button once to switch between.
1. Body Mode
˙This mode is used to measure the
forehead temperature.
˙It also provides clock.
2. Object Mode
˙This mode is used to measure the
object temperature.
˙It also provides clock.
08
Select the Temperature Unit
This meter provides two measurement units used for indicating
the body/object temperature, °C or °F, for your preferred selection.
1. Press Power button to turn ON
the meter. Press Setting Button
for 3 seconds to enter the screen.
2. Press Measure /
Memory Button to
toggle between °C
or °F.
3. Press Setting Button
to exit.
Replacing the Battery
The thermometer comes with two 1.5 V AAA alkaline batteries. The
meter will display "
" to alert you when the meter power is
getting low. Please follow the steps below to replace new batteries
immediately.
1. LCD side facing upwards.
2. Press the end link upwards and
remove it.
3. Remove old batteries and replace
with two 1.5 V AAA alkaline
batteries. Follow the correct
position of positive “+” and
negative “-“ as indication.
4. Insert and press the end link
downwards into the main unit.
NOTE:
1. Although the thermometer works when "
" appears, we still
recommend that you change the batteries to obtain an accurate
result.
2. Remove the batteries if planned to store for a long period of time.
3. The batteries should be kept away out of child’s reach. If they are
swallowed, promptly see a doctor for help.
09
Setting the Thermometer
You will need to set time for first-time use or after replacing the
batteries.
1. Entering the setting mode
Start with the meter ON, press Setting
Button for 5 seconds to enter the setting
mode.
2. To set the date and time
Press Measure / Memory Button to select
the correct year. Press Setting Button to
confirm and move to the next step. The
same step for month/day/hour/minute
settings.
Setting is all completed. Press Setting Button to exit the setting
mode.
10
DETAILED INFORMATION
About Normal Body Temperature and Fever
The temperature on the forehead and temple area differs from the
internal temperature, which is taken orally or rectally. Vasoconstriction, an effect which constricts the blood vessels and cools the
skin, can occur during the early stages of a fever. In this case, the
temperature measured by the NC100 Bluetooth Non-Contact
Infrared Thermometer may be unusually low. If the measurement
therefore does not match the patient’s own perception or is
unusually low, repeat the measurement every 15 minutes. As a
reference, you can also measure the internal body temperature
using a conventional oral or rectal thermometer.
Body temperature can vary from one individual/ person to next. It
also varies by location on the body and time of day. Below shows
the statistical normal ranges from different sites. Please keep in
mind that temperatures measured from different sites, even at the
same time, should not be directly compared. Fever indicates that
the body temperature is higher than normal. This symptom may be
caused by infection, overdressing or immunization. Some people
may not experience fever even when they are ill. These include, but
are not limited to, infants younger than 3 months old, persons with
compromised immune systems, persons taking antibiotics,
steroids or antipyretics (aspirin, ibuprofen, acetaminophen), or
persons with certain chronic illnesses. Please consult your
physician when you feel ill even if you do not have fever.
Table*1 Body Site Normal Temperature Range
Oral
Rectal/ear
Axillary
(armpit)
0.6°C (1°F) or more above or below
37°C (98.6°F)
0.3°C to 0.6°C (0.5°F to 1°F) higher
than oral temperature
0.3°C to 0.6°C (0.5°F to 1°F) lower
than oral temperature
*1. Body Temperature at WebMD;
website: http://firstaid.webmd.com/body-temperature
retrieved at 2010 Jan 7.
11
PERFORM THE TEST
Using the Device
As a Body Temperature Thermometer
1. Press Power Button to turn on
the meter.
When °C or °F blinks, temperature
can be measured.
2. Press Setting Button to select
Body Mode.
If you started with Object Mode.
3. Move the probe close to the
forehead.
Make sure the probe is flat , with 5 10 cm distance from the center of
forehead.
4. Press Measure/ Memory Button
to read the result.
The meter will take measurement
automatically.
The reading is shown together
with blue backlight and 1 long
beep.
5. Next Reading.
About 3 seconds afterwards (when
a short beep is heard), °C or °F blinks
again, and next temperature
measurement can be taken.
12
NOTE:
˙As the forehead measurement temperature is likely to be affected
by sweat, oil and the surroundings, the reading shall be taken as a
reference only.
˙If the probe is placed at an angle close to the forehead measure-
ment, the reading will be affected by surrounding temperature.
Babies’ skin reacts very quickly to the ambient temperature.
Therefore, do not take their temperature with the NC100
thermometer during or after breastfeeding, because the skin
temperature may then be lower than the internal body
temperature.
˙If the reading is < 32°C (89.6°F), the display will show together with
red backlight and two short beeps.
˙If the reading is ≥ 37.8 °C (100°F) and < 43°C (109.4°F), the display
will show together with red backlight and four short beeps.
˙The thermometer will automatically turn off if left idle for 60
seconds.
13
As an Object Measurement Thermometer
1. Press Power Button to turn on
the meter.
When °C or °F blinks, temperature
can be measured.
2. Press Setting Button to select
Object Mode.
If you started with Body Mode.
3. Move the probe close to the
object.
Make sure the probe is flat , not at
an angle. with 5 - 10 cm distance
from the object.
4. Press Measure/ Memory Button
to read the result.
The meter will take measurement
automatically.
The reading is shown together
with blue backlight and 1 long
beep.
5. Next Reading.
About 3 seconds afterwards (when
a short beep is heard), °C or °F blinks
again, and next temperature
measurement can be taken.
14
METER MEMORY
Recalling the Memory
Your thermometer stores 32 most recent forehead readings
1. Be sure the thermometer is OFF before
recalling this memory.
2. Press Measure / Memory Button to
enter the memory mode.
Each time you press the Measure /
Memory Button, a result will be
displayed in the order of dates (latest
result shown first), together with ”
”
and number (from 1 to 32).
Backlight in blue or red will appear
according to the memory reading.
When the memory is full, the oldest
result is deleted as the new one added.
When the last record displays on the
screen, press Measure / Memory Button
again to return to the first record.
3. Exit the memory.
Press Power Button to exit the memory
or keep the meter in idle for 60 seconds
to switch off automatically.
15
MAINTENANCE
Care and Cleaning
˙The probe is not waterproof. Please wipe with a clean and dry
cotton swab to clean the probe surface.
˙The body of the thermometer is not water-resistant. Never put
the thermometer under a running tap or submerge it into water.
Use a soft and dry cloth to clean it. Do not use abrasive cleaners.
˙Store the thermometer in a cool and dry location. Free from dust
and away from direct sunlight.
16
SYSTEM TROUBLESHOOTING
Measurement Result
MESSAGE
WHAT IT MEANS
Measured temperature falls outside
the displayed temperature range of
32°C to 43°C (89.6°F to 109.4°F), is
shown on the display with red
backlight.
˙Hi-temperature ≥ 43°C (109.4°F)
˙Lo-temperature < 32°C (89.6°F)
Measured temperature falls in normal
reading, within the range of 32°C to
37.8°C (89.6°F to 100°F), is shown on
the display with blue backlight.
Measured temperature falls in fever
reading, ≥ 37.8°C (100°F) and < 43°C
(109.4°F), is shown on the display with
red backlight.
17
Troubleshooting
The table below shows problems you may encounter. All error
messages below would be shown together with backlight. Please
follow "WHAT TO DO" to resolve problems. If the problem still
exists, please call your local dealer for help.
MESSAGE
18
WHAT IT MEANS
WHAT TO DO
Appear when
environmental
temperature is
below/above
system operation
range.
Put the
thermometer
under operating
temperature range
of 10°C to 40°C
(50°F to 104°F).
Battery is low and
" appears on
display.
Please replace
batteries as soon as
possible.
If the thermometer
is broken or
affected by EMF.
Please contact the
customer service
line.
SYMBOL INFORMATION
Consult instructions for use
Manufacturer
Serial Number
Caution, consult accompanying documents
CE mark
Authorised Representative in the European Community
Type BF Equipment
Do not use if package is damaged
19
SPECIFICATIONS
Dimensions
185.1mm(L) x 58mm(W) x 29.1mm(H)
Weight
93g (include 2 x1.5V AAA batteries)
Battery
2 x 1.5 V AAA alkaline batteries
Measuring
Forehead: 32.0°C to 42.9°C (89.6°F to 109.2°F)
temperature range Object: 0.0°C to 100.0°C (32.0°F to 212.0°F)
Display resolution
0.1°C/ 0.2 °F
Accuracy
±0.2°C / 0.4 °F (32.0 ~ 42.9°C / 89.6~ 109.2 °F )
±1.0°C / 2.0 °F (0.0 ~ 100.0°C / 32.0 ~ 212.0 °F )
Temperature unit
°C or °F
Operating
10°C to 40°C (50.0°F to 104.0°F)
temperature range
Operating humidity ≦80% RH non-condensing
Storage
-25°C to 55°C (-13.0°F to 131.0°F)
temperature range
Storage humidity
≦95% RH non-condensing
Memory capacity
32 measurements
20
STATEMENTS AND DECLARATIONS:
1. This product needs special precautions regarding EMC and
needs to be installed and put into service according to the EMC
information provided, and this unit can be affected by portable
and mobile RF communications equipment.
2. Do not use a mobile phone or other devices that emit
electromagnetic fields, near the unit. This may result in incorrect
operation of the unit.
3. Caution: This unit has been thoroughly tested and inspected to
assure proper performance and operation!
4. Caution: this machine should not be used adjacent to or
stacked with other equipment and that if adjacent or stacked
use is necessary, this machine should be observed to verify
normal operation in the configuration in which it will be used.
Guidance and manufacture’s
declaration – electromagnetic emission
The NC100 is intended for use in the electromagnetic
environment specified below. The customer of the user of the
NC100 should assure that it is used in such an environment.
Emission test
RF emissions
CISPR 11
RF emission
CISPR 11
Compliance
Group 1
Group B
Electromagnetic
environment – guidance
The NC100 use RF energy
only for its internal
function. Therefore, its RF
emissions are very low and
are not likely to cause any
interference in nearby
electronic equipment.
The NC100 is suitable for
use in all establishments,
including domestic
establishments and those
directly connected to the
public low-voltage power
supply network that
supplies buildings used for
domestic purposes.
21
Guidance and manufacture’s
declaration – electromagnetic immunity
The NC100 is intended for use in the electromagnetic
environment specified below. The customer or the user of
NC100 should assure that it is used in such an environment.
Immunity test
Electrostatic
discharge (ESD)
IEC 61000-4-2
Power
frequency
(50Hz/60Hz)
magnetic
field
IEC 61000-4-8
IEC 60601
test level
±6 kV contact
±8 kV air
3 A/m
Compliance
level
Electromagnetic
environment - guidance
±6 kV contact
±8 kV air
Floors should be wood,
concrete or ceramic
tile. If floors are
covered with synthetic
material, the relative
humidity should be at
least 30%.
3 A/m
Power frequency
magnetic fields should
be at levels
characteristic of a
typical location in a
typical commercial or
hospital environment.
NOTE UT is the a.c. mains voltage prior to application of the
test level.
22
DISPOSAL
Adhere to the applicable regulations when
disposing of the device.
This product must not be disposed of
together with domestic waste.
All users are obliged to hand in all electrical or electronic devices,
regardless of whether or not they contain toxic substances, at a
municipal or commercial collection point so that they can be
disposed of in an environmentally acceptable manner.
Please remove the batteries before disposing of the device/unit.
Do not dispose of old batteries with your household waste, but at
a battery collection station at a recycling site or in a shop.
23
The statements should be displayed in the user manual:
changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
The statements should be displayed in the user manual:
changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
24
WARRANTY
˙ Tyson Bioresearch, Inc. offers a 2 years guarantee on this
product excluding batteries. Our company shall repair or
replace any Tyson Bio Bluetooth Non-Contact Infrared
Thermometer found defective with a new one.
˙ This warranty does not apply to the performance of a Tyson Bio
Bluetooth Non-Contact Infrared Thermometer that has been
accidentally damaged, altered, misused, tampered with or
abused in any way. In no event shall our company be liable to
the purchaser or any other person for any incidental,
consequential, or punitive damages arising from or in any way
connected with the purchase or operation of Tyson Bio
Bluetooth Non-Contact Infrared Thermometer.
˙ For manufacturer warranty services, purchaser must contact
Tyson Bioresearch, Inc. for help.
25
Tyson Bioresearch, Inc.
5F., No. 16, 18, 20, 22, Kedong 3rd Rd.,
Zhunan Township, Miaoli County 35053, Taiwan
www.tysonbio.com
Customer Service
+886-37-585998 (8:30 ~ 17:30, Monday ~ Friday)
Medical Device Safety Service GmbH
Schiffgraben 41, D-30175 Hannover, Germany
is either registered trademark or trademark of Tyson Bioresearch Inc.
Copyright 2016 Tyson Bioresearch Inc. All rights reserved.
All product images do not reflect actual sizes.
AF004-0044000N (01)
Rev. date: 10/2017

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2017:10:19 17:43:55+08:00
Creator                         : Adobe Illustrator CC 2017 (Macintosh)(Infix Pro)
ICN App Name                    : Infix Pro
ICN App Platform                : Windows
ICN App Version                 : 6.50
Modify Date                     : 2018:01:23 11:22:41+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Instance ID                     : uuid:95a36ece-f0d0-4ffe-a79b-46e051c919e3
Document ID                     : xmp.did:842ea261-c6b7-4621-a8a8-56f0323db6ff
Original Document ID            : adobe:docid:indd:97ef6f82-2329-11e2-a25d-c4faebf2fd8f
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:18bd3d40-fe55-a34f-901c-ae9d1c29ef76
Derived From Document ID        : xmp.did:bf07f971-b112-5b42-9399-d1c8f159594d
Derived From Original Document ID: adobe:docid:indd:97ef6f82-2329-11e2-a25d-c4faebf2fd8f
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:F57EDDDB2A48E211AC5FAD4D5C4BAE4C, xmp.iid:F67EDDDB2A48E211AC5FAD4D5C4BAE4C, xmp.iid:31D7E8B42B48E211AC5FAD4D5C4BAE4C, xmp.iid:a1fb7f78-bb42-ca41-bac4-39e11b02e86c, xmp.iid:842ea261-c6b7-4621-a8a8-56f0323db6ff
History When                    : 2012:12:17 17:19:28+08:00, 2012:12:17 17:19:28+08:00, 2012:12:17 17:25:33+08:00, 2017:06:06 14:06:59+08:00, 2017:10:19 17:43:48+08:00
History Software Agent          : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe Illustrator CC 2017 (Windows), Adobe Illustrator CC 2017 (Macintosh)
History Changed                 : /;/metadata, /metadata, /;/metadata, /, /
Manifest Link Form              : EmbedByReference
Manifest Reference File Path    : /Volumes/tysonbio_arts/Tysonbio Advertisement Material(RiDATA)/TysonBio_包材(全)/TysonBio_包材/NC100/NC100_KitBox/LINK/NC100 Meter.psd
Manifest Reference Document ID  : adobe:docid:photoshop:4394f73f-afd1-11e7-83b3-cf25c0f2c751
Manifest Reference Instance ID  : xmp.iid:83ac3b77-f9d8-4b6c-a913-c5df38a5df8f
Ingredients File Path           : /Volumes/tysonbio_arts/Tysonbio Advertisement Material(RiDATA)/TysonBio_包材(全)/TysonBio_包材/NC100/NC100_KitBox/LINK/NC100 Meter.psd
Ingredients Document ID         : adobe:docid:photoshop:4394f73f-afd1-11e7-83b3-cf25c0f2c751
Ingredients Instance ID         : xmp.iid:83ac3b77-f9d8-4b6c-a913-c5df38a5df8f
Metadata Date                   : 2018:01:23 11:22:41+08:00
Creator Tool                    : Adobe Illustrator CC 2017 (Macintosh)(Infix Pro)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 6385 bytes, use -b option to extract), (Binary data 2570 bytes, use -b option to extract)
Thumbnail Width                 : 20
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 2834 bytes, use -b option to extract)
Doc Change Count                : 9
Format                          : application/pdf
Title                           : NC100_UserManual_171019
Producer                        : Adobe PDF library 15.00
Trapped                         : False
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : True
Max Page Size W                 : 58.000000
Max Page Size H                 : 101.500000
Max Page Size Unit              : Millimeters
Font Name                       : MicrosoftJhengHeiRegular, AdobeMingStd-Light, MyriadPro-Regular, MyriadPro-Semibold, MyriadPro-Bold, MyriadPro-BoldIt, MyriadPro-Black, MyriadWebPro-Bold, Arial-BoldMT, BakerSignetBT-Roman
Font Family                     : 微軟正黑體, Adobe 明體 Std, Myriad Pro, Myriad Pro, Myriad Pro, Myriad Pro, Myriad Pro, Myriad Web Pro, Arial, BakerSignet BT
Font Face                       : Regular, L, Regular, Semibold, Bold, Bold Italic, Black, Bold, Bold, Roman
Font Type                       : Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type, TrueType
Font Version                    : Version 6.02, Version 6.008;PS 6.001;hotconv 1.0.67;makeotf.lib2.5.33168, Version 2.106;PS 2.000;hotconv 1.0.70;makeotf.lib2.5.58329, Version 2.106;PS 2.000;hotconv 1.0.70;makeotf.lib2.5.58329, Version 2.106;PS 2.000;hotconv 1.0.70;makeotf.lib2.5.58329, Version 2.062;PS 2.000;hotconv 1.0.57;makeotf.lib2.0.21895, OTF 1.006;PS 001.000;Core 1.0.23;hotunix 1.28, Version 001.014, Version 5.21, mfgpctt-v1.57 Friday, February 19, 1993 3:30:24 pm (EST)
Font Composite                  : False, False, False, False, False, False, False, False, False, False
Font File Name                  : msjh.ttf, AdobeMingStd-Light.otf, MyriadPro-Regular.otf, MyriadPro-Semibold 2.otf, MyriadPro-Bold.otf, MyriadPro-BoldIt.otf, MyriadPro-Black.otf, MyriadWebPro-Bold.ttf, arialbd.ttf, BAKRSIGN.TTF
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Group Name               : 預設色票群組
Swatch Group Type               : 0
Swatch Colorant Swatch Name     : C=50 M=0 Y=90 K=0, C=10 M=100 Y=100 K=0, PANTONE 877 C, PANTONE Cool Gray 9 C, AutoCAD Color
Swatch Colorant Type            : PROCESS, PROCESS, SPOT, SPOT, PROCESS
Swatch Colorant Tint            : 100.000000, 100.000000, 100.000000, 100.000000, 100.000000
Swatch Colorant Mode            : CMYK, CMYK, Lab, Lab, CMYK
Swatch Colorant Cyan            : 51.894403, 18.725871, 0.000000
Swatch Colorant Magenta         : 6.390478, 99.487293, 96.050960
Swatch Colorant Yellow          : 88.986033, 100.000000, 94.705117
Swatch Colorant Black           : 0.000000, 0.000000, 0.000000
Swatch Colorant L               : 59.607800, 50.196098
Swatch Colorant A               : -1, 0
Swatch Colorant B               : -1, -2
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ADNQNC100

Navigation menu