Fuji Bikes Feh381 Users Manual FEH381_HARDWARE

UG230H-SS4x 2701fcfb-16f6-4677-8d66-77b9e9199e25

UG230H-SS4x to the manual 2701fcfb-16f6-4677-8d66-77b9e9199e25

2015-02-09

: Fuji-Bikes Fuji-Bikes-Feh381-Users-Manual-552547 fuji-bikes-feh381-users-manual-552547 fuji-bikes pdf

Open the PDF directly: View PDF PDF.
Page Count: 124

DownloadFuji-Bikes Fuji-Bikes-Feh381-Users-Manual- FEH381_HARDWARE  Fuji-bikes-feh381-users-manual
Open PDF In BrowserView PDF
Create Tomorrow with
Trustworthy Technology

FUJI UG230 SERIES PROGRAMMABLE OPERATION DISPLAY

USER’S MANUAL 
TYPE: UG230H-LS4x
UG230H-SS4x
UG230H-TS4x

FEH381

Preface
Thank you for selecting the Fuji Programmable Operation Display, POD UG230 Series (called as the UG230 or
POD hereafter).
This User’s Manual  explains system configuration, specifications and handling of the UG230
Series. To enable you to fully utilize the display, carefully read this User’s Manual.
For more information on the UG230 Series, refer to the following manuals as well.
Name

Manual No.

Contents

UG Series 

FEH375

Describes operating procedures of the screen editor
(UG00S-CW) for the UG Series.

UG Series 

FEH376

Describes the functions available with the UG30/20
Series.

UG Series 

FEH380

Describes connections with PLCs, universal serial
communications, etc.

UG Series 
UG Series 

FEH376-1

Supplementary information for the UG Series


FEH350

Tutorial manual for novices in the UG Series

For further details about PLCs (programmable logic controllers), see the manual attached to each PLC.

Notes:
1. This manual may not, in whole or in part, be printed or reproduced without the prior written consent of
Fuji Electric FA Components & Systems Co., Ltd.
2. The information in this manual is subject to change without prior notice.
3. Windows and Excel are registered trademarks of Microsoft Corporation in the United States and other
countries.
4. All other company names or product names are trademarks or registered trademarks of their
respective holders.
5. This manual is intended to give accurate information about POD hardware. If you have any
questions, please contact your local distributor.

Record of Revisions
Reference numbers are shown at the bottom left corner on the back cover of each manual.
Printing Date
February, 2004

Reference No.
FEH381

Revised Contents
First edition

Notes on Safe Use of POD
In this manual, you will find various notes categorized under the following levels with the signal words “DANGER,”
and “CAUTION.”

DANGER

Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury and could cause property damage.

Note that there is a possibility that the item listed with

CAUTION

may have serious ramifications.

DANGER
• Never use the input function of POD for operations that may threaten human life or to damage the system,
such as switches to be used in case of emergency. Please design the system so that it can cope with
malfunction of a touch switch. A malfunction of the touch switch will result in machine accident or damage.
• Turn off the power supply when you set up the unit, connect cables or perform maintenance and inspection.
Otherwise, electrical shock or damage may occur.
• Never touch any terminals while the power is on. Otherwise, electric shock may occur.
• You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Without
the terminal cover in place, an electric shock may occur.
• The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, never swallow
the leaked liquid crystal. If the liquid crystal spills on your skin or clothing, use soap and wash off thoroughly.
• For POD using a lithium battery, never disassemble, recharge, deform by pressure, short-circuit, nor reverse
the polarity of the battery, and never dispose of the battery in fire. Failure to follow these conditions will lead
to explosion or ignition.
• For POD using a lithium battery, never use a battery that is deformed, leaks, or shows any other signs of
abnormality. Failure to follow these conditions will lead to explosion or ignition.

CAUTION
• Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is
found. Failure to do so may lead to fire, damage or malfunction.
• For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or
mobile installations, please consult your local distributor.
• Operate (or store) POD under the conditions indicated in this manual and related manuals. Failure to do so
could cause fire, malfunction, physical damage or deterioration.
• Understand the following environmental limits for use and storage of POD. Otherwise, fire or damage to the
unit may result.
- Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding
fluids or cutting oil can come into contact with the unit.
- Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct
sunlight.
- Avoid locations where excessive dust, salt, and metallic particles are present.
- Avoid installing the unit in a location where vibration or physical shock may be transmitted.
• Equipment must be correctly mounted so that the main terminal of POD will not be touched inadvertently.
Otherwise, an accident or electric shock may occur.
• Tighten the fixtures of the POD with a torque in the specified range. Excessive tightening may distort the
panel surface. Loose tightening may cause POD to come off, malfunction or be short-circuited.
• Check periodically that terminal screws on the power supply terminal block and fixtures are firmly tightened.
Loosened screws may result in fire or malfunction.
• Tighten terminal screws on the power supply terminal block equally to a torque of 0.5 N•m. Improper
tightening of screws may result in fire, malfunction, or trouble.
• POD has a glass screen. Do not drop or give physical shock to the unit. Otherwise, the screen may be
damaged.
• Connect the cables correctly to the terminals of POD in accordance with the specified voltage and wattage.
Over-voltage, over-wattage or incorrect cable connection could cause fire, malfunction or damage to the
unit.
• Be sure to establish a ground of POD. Ground FG terminal which must be used for the unit. Otherwise,
electric shock or a fire may occur.
• Prevent any conductive particles from entering into POD. Failure to do so may lead to fire, damage or
malfunction.
• After wiring is finished, remove the paper used as a dust cover before starting to operate POD. Operation
with the cover attached may result in accident, fire, malfunction, or trouble.
• Do not attempt to repair POD at your site. Ask us or the designated contractor for repair.
• Do not disassemble or modify POD. Otherwise, it may cause a malfunction.
• Fuji Electric FA Components & Systems Co., Ltd. is not responsible for any damages resulting from repair,
overhaul or modification of POD that was performed by an unauthorized person.
• Do not use a sharp-pointed tool when pressing a touch switch. Doing so may damage the screen.
• Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspection.
• For POD using a lithium battery, handle the battery with care. The combustible materials such as lithium or
organic solvent contained in the battery may generate heat, explode, or catch fire, resulting in personal injury
or fire. Read related manuals carefully and handle the lithium battery correctly as instructed.
• When using a POD that has analog switch resolution with resistance film, do not press two or more points on
the screen at the same time. If there is a switch between the two pressed points, it may be activated.
• Take safety precautions during such operations as setting change during running, forced output, start, and
stop. Any misoperation may cause unexpected machine motions, resulting in machine accident or damage.
• In facilities where a failure of POD could lead to accident threatening human life or other serious damage, be
sure that the facilities are equipped with adequate safeguards.
• At the time of disposal, POD must be treated as industrial waste.
• Before touching POD, discharge static electricity from your body by touching grounded metal. Excessive
static electricity may cause malfunction or trouble.

[General Notes]
• Never bundle control cables and input/output cables with high-voltage and large-current carrying cables such
as power supply cables. Keep these cables at least 200 mm away from the high-voltage and large-current
carrying cables. Otherwise, malfunction may occur due to noise.
• Plug connectors or sockets of POD in the correct orientation. Otherwise, it may cause a malfunction.
• Do not use thinners for cleaning because they may discolor the POD surface. Use alcohol or benzine
commercially available.
• If a data receive error occurs when POD and the counterpart (PLC, temperature controller, etc.) are started at
the same time, read the manual for the counterpart unit and handle the error correctly.
• Avoid discharging static electricity on the mounting panel of the POD. Static charges can damage the unit and
cause malfunctions. Otherwise, malfunction may occur due to noise.
• Avoid prolonged display of any fixed pattern. Due to the characteristics of the liquid crystal display, an
afterimage may occur. If a prolonged display of a fixed pattern is expected, use the auto OFF function of the
backlight.

Contents
Preface
Notes on Safe Use of POD
Chapter 1

Overview

1.

Features............................................................................................................................................ 1-1

2.

Models and Peripheral Equipment.................................................................................................... 1-2
POD Models ........................................................................................................................................................1-2
Peripheral Equipment..........................................................................................................................................1-3

3.

System Composition ......................................................................................................................... 1-6
System Composition of UG230 ...........................................................................................................................1-6
System Composition of UG230 + UG230A-DCL.................................................................................................1-7

Chapter 2
1.

Specifications
Specifications .................................................................................................................................... 2-1
General Specifications ........................................................................................................................................2-1
Display Specifications .........................................................................................................................................2-2
Touch Switch Specifications ...............................................................................................................................2-2
Function Switch Specifications............................................................................................................................2-2
Interface Specifications .......................................................................................................................................2-3
Clock and Backup Memory Specifications ..........................................................................................................2-3
Drawing Environment ..........................................................................................................................................2-3
Display Function Specifications ..........................................................................................................................2-4
Function Performance Specifications..................................................................................................................2-5

2.

Dimensions and Panel Cut-out ......................................................................................................... 2-6
UG230 External View and Dimensions ...............................................................................................................2-6
UG230 + UG230A-DCL External View and Dimensions.....................................................................................2-7

3.

Names and Functions of Components.............................................................................................. 2-8

4.

Modular Jack (MJ1/MJ2)................................................................................................................. 2-10
Modular Jack 1 (MJ1)........................................................................................................................................2-10
Modular Jack 2 (MJ2: Exclusive to the UG230) ................................................................................................2-11
Notes on Wiring.................................................................................................................................................2-14
Transferring Screen Data ..................................................................................................................................2-17
Barcode Reader Connection .............................................................................................................................2-17
Printer Connection (Serial Printer) ....................................................................................................................2-18

5.

USB Connectors ............................................................................................................................. 2-19
USB-A (Master Port) .........................................................................................................................................2-19
USB-B (Slave Port) ...........................................................................................................................................2-20

6.

D-sub 25-Pin Connector (CN1) (Optional) ...................................................................................... 2-25
Serial Connector (CN1) .....................................................................................................................................2-25

7.

10BASE-T (LAN) (Optional)............................................................................................................ 2-26
10BASE-T Connector........................................................................................................................................2-26
Notes on Wiring.................................................................................................................................................2-27

8.

CF Card .......................................................................................................................................... 2-28
Recommended CF Cards .................................................................................................................................2-28
CF Card Insertion Position ................................................................................................................................2-28
Mounting and Dismounting the CF Card ...........................................................................................................2-29
Notes on Handling the CF Card ........................................................................................................................2-30

Chapter 3
1.

Installation
Mounting Procedure.......................................................................................................................... 3-1
Mounting Procedure............................................................................................................................................3-1
Mounting Angle ...................................................................................................................................................3-1

2.

Power Supply Cable Connection ...................................................................................................... 3-2
Power Supply Cable Connection ........................................................................................................................3-2
Grounding ...........................................................................................................................................................3-3

Chapter 4
1.

Instructions
Coin-type Lithium Battery .................................................................................................................. 4-1
Battery Mounting Procedure ...............................................................................................................................4-1
Battery Replacement ..........................................................................................................................................4-2

2.

DIP Switch Setting ............................................................................................................................ 4-4

3.

Function Switches ............................................................................................................................. 4-5

DIP Switch (DIPSW) Setting ...............................................................................................................................4-4

Types ..................................................................................................................................................................4-5
[SYSTEM] Switch................................................................................................................................................4-5

Chapter 5

Connections

1.

1 : 1 Connection ................................................................................................................................ 5-1

2.

1 : n Connection (Multi-drop)............................................................................................................. 5-2

3.

n : 1 Connection (Multi-link 2) ........................................................................................................... 5-3

4.

n : 1 Connection (Multi-link) .............................................................................................................. 5-4

5.

Universal Serial Communications ..................................................................................................... 5-5

6.

UG-Link ............................................................................................................................................. 5-6

7.

PLC2Way .......................................................................................................................................... 5-7

8.

Temperature Control Network........................................................................................................... 5-8

9.

Ethernet............................................................................................................................................. 5-9

Chapter 6

POD Operations

1.

Operational Procedures .................................................................................................................... 6-1

2.

Main Menu Screen ............................................................................................................................ 6-4

POD Operation ...................................................................................................................................................6-1

Displaying the Main Menu Screen ......................................................................................................................6-4
Moving Back to the Screen in the RUN Mode ....................................................................................................6-4
Main Menu Screen ..............................................................................................................................................6-5

1.

I/O Test ............................................................................................................................... 6-5
1-1.

2.

3.

USB Test................................................................................................................... 6-6

1-2.

Serial Connection Test.............................................................................................. 6-7

1-3.

SYSTEM & Function Switch Test ........................................................................... 6-13

1-4.

Touch Switch Test .................................................................................................. 6-13

Card Menu Screen ............................................................................................................ 6-15
2-1.

Card Recorder Menu Screen .................................................................................. 6-16

2-2.

Transferring Screen Data from a CF Card.............................................................. 6-18

2-3.

Saving Backup Copies of SRAM ............................................................................ 6-24

2-4.

Messages during Data Transfer.............................................................................. 6-26

Communication Parameter Screen ................................................................................... 6-27

4.
5.

Chapter 7
1.

2.

Extension Program Information ........................................................................................ 6-28
Ethernet (Optional)............................................................................................................ 6-29
5-1.

Ethernet Information Screen................................................................................... 6-29

5-2.

IP Address Setting .................................................................................................. 6-30

6.

SRAM/Clock...................................................................................................................... 6-36

7.

Extended Function Setting................................................................................................ 6-38

Error Correction
Error Messages................................................................................................................................. 7-1
1.

Communication Error .......................................................................................................... 7-1

2.

Check.................................................................................................................................. 7-3

3.

Warning............................................................................................................................... 7-3

4.

SYSTEM ERROR ............................................................................................................... 7-4

5.

Touch Switch is Active ........................................................................................................ 7-4

Troubleshooting ................................................................................................................................ 7-5
In the Event of an Error .......................................................................................................................................7-5
Probable Symptoms ............................................................................................................................................7-5

Chapter 8
1.

Inspection and Maintenance
Inspection and Maintenance ............................................................................................................. 8-1
Daily Inspection ...................................................................................................................................................8-1
Periodical Inspection ...........................................................................................................................................8-1

2.

Warranty Policy ................................................................................................................................. 8-2
Inquiries about Failure.........................................................................................................................................8-2
Warranty Period ..................................................................................................................................................8-2
Free-of-charge Repair .........................................................................................................................................8-2
Chargeable Repair ..............................................................................................................................................8-2

1

Overview

1.

Features

2.

Models and Peripheral Equipment

3.

System Composition

1. Features

1.

1-1

Features
1. 32k-color Display (except for UG230H-LS4x)
32,768-color display makes colorful expression possible.
JPEG files and bitmap files are clearly displayed in brilliant colors.
2. USB Master/Slave Port as Standard
Two ports are provided as standard for diverse applications.
At the master port, a USB-compatible EPSON STYLUS PHOTO series printer or CF card
reader/writer can be used.
On-site versatility is extended further.
At the slave port, large quantities screen data can be transferred from the computer at a high
speed.
3. SRAM and Clock Function as Standard
A 128 kbyte SRAM is standard, allowing backup copies of recipe data or sampling data to be
saved with ease.
4. CF Card Interface Supported (USB master port/optional)
The CF card can be used for saving multiple screen data, sampling data, recipe data, hard copy
images, and other various usages.
JPEG files and font files can also be saved.
5. 10BASE-T Connector Supported (optional)
This connector enables Ethernet connection with a host computer or PLC.
High-speed communications are possible via Ethernet for transferring screen data and
reading/writing data from/to the server.
6. Analog Switch/Matrix Switch Supported
The switch type can be selected from the lineup according to your application.
A variety of switch types is available to suit your requirements.

Overview

The UG230 series inherits and heightens the features of the UG20 series as described below.

1

1-2

2.

2. Models and Peripheral Equipment

Models and Peripheral Equipment

POD Models
The model name consists of the following information.

UG 2 30 H - L S 4 D
Screen size
2: 5.7-inch

Touch switch specification
None: Analog switch
D: Matrix switch

Version information

Power supply specification
4: 24 VDC specification
(in compliance with CE/UL/cUL)

POD unit type

Functional specification
S: Standard
Device specification
T: TFT color LCD (QVGA)
S: STN color LCD (QVGA)
L: STN monochrome LCD (QVGA)

The following models are available.
Series and Size

UG230 series
5.7-inch

Model Name

Specifications

Remarks

UG230H-TS4

TFT color, 320 × 240 dots, analog switch
DC power supply

Compliant with
CE/UL/cUL

UG230H-TS4D

TFT color, 320 × 240 dots, matrix switch
DC power supply

Compliant with
CE/UL/cUL

UG230H-SS4

STN color, 320 × 240 dots, analog switch
DC power supply

Compliant with
CE/UL/cUL

UG230H-SS4D

STN color, 320 × 240 dots, matrix switch
DC power supply

Compliant with
CE/UL/cUL

UG230H-LS4

STN monochrome, 320 × 240 dots, analog switch
DC power supply

Compliant with
CE/UL/cUL

UG230H-LS4D

STN monochrome, 320 × 240 dots, matrix switch
DC power supply

Compliant with
CE/UL/cUL

2. Models and Peripheral Equipment

1-3

Peripheral Equipment

1

The following options are available for using the UG230 series more effectively.

Application software for editing display data for the POD.
(Windows98/NT4.0/Me/2000/XP compatible)
The UG230 series is supported with ver. 3.2.0.0 and later.

UG230A-DCL (option unit)
Optional unit to be used for D-sub 25-pin connector, CF card and Ethernet.

UG230P-D4 (FLASH memory cassette)
Extension print circuit board to extend the memory for screen data.
The capacity of FLASH memory is 4 Mbyte.
* Only when the UG230A-DCL (option unit) is provided

UG00P-TC (terminal converter)
Used for connection between the UG30 series and a PLC at the RS-422/485 terminal block.
1

CN

SW

1

TB

1

* Only when the UG230A-DCL (option unit) is provided

UG00P-MR (card recorder)
The card recorder creates a backup copy of screen data or works as an external memory
storage system for memory manager and data logging functions.

UG00K-xx (memory card) compliant with JEIDA ver. 4.0
Used with the card recorder when having a backup copy of screen data or saving data on an
external medium for memory manager and data logging functions.
SRAM
256 K, 512 K, 1 M, 2 M, 4 Mbyte
FLASH ROM 256 K, 512 K, 1 Mbyte

UG00P-MS (memory card editor: English/Japanese)
Application software for editing data stored on a memory card, SRAM or CF card.
(Windows98/NT4.0/Me/2000/XP compatible)

Overview

UG00S-CWV3 (configuration software: English/Japanese)

1-4

2. Models and Peripheral Equipment

UG00P-DI (ACPU/QnACPU/FXCPU dual port interface)
G

P

P

Add-on connector with two ports, specifically designed for the connector on the
MITSUBISHI’s ACPU/QnACPU/FXCPU programmer. Operability can be improved when
directly connecting the POD to the ACPU/QnACPU/FXCPU programmer.

123

* Only when the UG230A-DCL (option unit) is provided

GD

UG00P-U2 (serial extension I/O)
Used as an external I/O unit for PLC. It has 16 inputs and 16 outputs.
DC24V
IN1
FG

IN3

MJ1

IN5
IN0

IN7
IN2

IN9
IN4

IN11
IN6

IN13
IN8

IN15
IN10
IN12

OUT1
IN14

OUT3

COM+

OUT5
OUT0

OUT7
OUT2

OUT8
OUT4

OUT10
OUT6

OUT12
COM1

OUT14
OUT9

COM2
OUT11
OUT13
OUT15

UG00C-T (screen data transfer cable) 3 m
Used for connection between the POD and a personal computer, or a personal computer
and the card recorder (UG00P-MR).

UG00C-B (barcode reader connection cable) 3 m
Used for connection between the POD and a barcode reader.
This is also used for connection between the POD and a temperature controller via
RS-232C.

UG00C-H (multi-link 2 master cable/temperature controller connection cable) 3 m
Used for Multi-Link 2 connection between the POD master station and the POD slave
station.
This is also used for connection between the POD and a temperature controller via RS-422
(485).

UG00C-P (temperature controller connection cable) 3 m
Used for connection between the POD and a temperature controller or a PLC using the
PLC2Way function via RS-422 (4-wire connection).
This is also used for connection with a PLC at the MJ2 port on the UG230.

UG30C-J (MJ2-to-D-sub conversion cable) 0.3 m
Used for connection between the UG230 and a PLC at MJ2.

2. Models and Peripheral Equipment

UG30C-M (MJ-to-D-sub conversion cable) 0.3 m
Used for connection of the POD via PLC2Way.

1-5

1
Overview

UGxxP-PS (protective sheet)
This sheet protects the operation panel surface. (5 sheets/set)

UGxxP-PT (protective sheet)
This anti-glare sheet protects the operation panel surface. (5 sheets/set)

UG30P-BT (battery for replacement)
Replacement lithium battery for the UG30 series.

1-6

3.

3. System Composition

System Composition

System Composition of UG230
The following illustration shows possible system configurations using the UG230.
UG series
configuration
software

UG230
(USB master)

(USB slave)
Creating screens

disc

USB-B

USB-A

RESET

UG00S-CW

MJ1

MJ2

Transferring
screen data

Computer (PC)

UG00C-T
During operation
(Link/universal serial communication)

RS-232C/RS-422
UG00C-P
Temperature controller,
inverter

UG00C-B
Link unit/
general-purpose computer

Barcode reader

DC24V
IN1
FG

IN3

MJ1

IN5
IN0

IN7
IN2

IN9
IN4

IN11
IN6

IN13
IN8

IN15
IN10
IN12

OUT1
IN14

OUT3

COM+

OUT5
OUT0

OUT7
OUT2

OUT8
OUT4

OUT10
OUT6

OUT12
COM1

OUT14
OUT9

COM2
OUT11
OUT13
OUT15

UG00P-U2

CF card
reader/writer

CF

96MB

Card recorder

UG00P-MR
Printer

RW

3. System Composition

1-7

1

System Composition of UG230 + UG230A-DCL

disc

disc

RESET

RESET

Ethernet
Computer (PC)

Computer (PC)

UG series
configuration
software

UG230+UG230A-DCL
(USB slave)

During operation
(Link/universal serial
communication)
RS-232C/RS-422

LAN

USB-B
Creating screens

D-sub

disc

UG00C-T

MJ1

RESET

Transferring
screen data MJ1/MJ2

UG00S-CW
Computer (PC)

USB-A
(USB master)

UG00C-P
Temperature controller,
inverter

UG00C-B
Barcode reader

Link unit/
general-purpose computer

DC24V
IN1
FG

IN3

MJ1

IN5
IN0

IN7
IN2

IN9
IN4

IN11
IN6

IN13
IN8

IN15
IN10
IN12

OUT1
IN14

OUT3

COM+

OUT5
OUT0

OUT7
OUT2

OUT8
OUT4

OUT10
OUT6

OUT12
COM1

OUT14
OUT9

COM2
OUT11
OUT13
OUT15

CF

UG00P-U2

RW

96MB

Card recorder

UG00P-MR

Printer

CF card
reader/writer

Overview

The following illustration shows possible system configurations using the UG230 and the
UG230A-DCL.

1-8

3. System Composition

Please use this page freely.

2

Specifications

1.

Specifications

2.

Dimensions and Panel Cut-out

3.

Names and Functions of Components

4.

Modular Jack (MJ1/MJ2)

5.

USB Connectors

6.

D-sub 25-Pin Connector (CN1) (Optional)

7.

10BASE-T (LAN) (Optional)

8.

CF Card

1. Specifications

1.

2-1

Specifications

2

General Specifications
Item

Specifications
24 VDC
24 VDC ± 10%

Permissible Range of Voltage
Power
Supply

Permissible Momentary Power Failure

Within 1 ms

Power Consumption
(Maximum Rating)

16 W or less

Rush Current
Withstand Voltage

20 A or less (with a rise time 0.1 ms)
DC external terminals to FG: 500 VAC, 1 minute

Insulation Resistance

Physical
Environment

500 VDC, 10 MΩ or above

Ambient Temperature

0°C to +50°C *

Storage Ambient Temperature

−10°C to +60°C

Ambient Humidity
Solvent Resistance
Atmosphere

85% RH or less (without dew condensation)
No cutting oil or organic solvent attached to the unit
No corrosive gas or conductive dust
Vibration frequency: 10 to 150 Hz, Acceleration: 9.8 m/s2
Single amplitude: 0.075 mm, X, Y, Z: 3 directions for one hour

Mechanical
Working
Conditions

Vibration Resistance
Shock Resistance

Pulse shape: Sine half wave
Peak acceleration: 147 m/s2, X, Y, Z: 3 directions six times each

Electrical
Working
Conditions

Noise Resistance

1000 Vp-p (pulse width 1µs, rise time: 1 ns)
Compliant with IEC61000-4-2,
contact: 6 kV, air: 8 kV

Static Electricity Discharge Resistance
Grounding

Grounding resistance: less than 100 Ω
Protection structure:

Structure
Mounting
Conditions

Cooling System
Weight
External Dimensions W × H × D (mm)
Panel Cut-out Dimensions (mm)

Front panel: compliant with IP65 (when using
waterproof gasket)
Rear case: compliant with IP20
Form:
In a single body
Mounting procedure: Inserted in a mounting panel
Cooling naturally
Unit only: approx. 680 g, with UG230A-DCL installed: approx. 820 g
Unit only: 182.5 × 138.8 × 42.5,
with UG230A-DCL installed: 182.5 × 138.8 × 64.0
+0.5
174 +0.5
−0 × 131 −0

Case Color

Black (Munsell N2.0)

Material

PC/PS resin (Tarflon)
* As for UG230H-SS4x and UG230H-LS4x, operation for long hours at ambient temperatures of 40 to 50°C may
degrade the display quality, such as lowering contrast.

Specifications

Rated Voltage

2-2

1. Specifications

Display Specifications
Model

Item
Display Device

UG230H-TS4x

UG230H-SS4x

UG230H-LS4x

TFT color LCD

STN color LCD

STN monochrome LCD

Display Size

5.7-inch
32,768 colors
+16-color blinks

Colors
Resolution

W × H (dots)

Dot Pitch

W × H (mm)

Brightness

Monochrome 8-grade
+ blink
320 × 240

0.36 × 0.36

0.36 × 0.36

0.36 × 0.36

350

160

220

(cd/m2)

Contrast Ratio
Angle of Vertical Visibility (°)
Angle of Horizontal Visibility (°)

60 : 1

30 : 1

5:1

+65, −40

+20, −35

+20, −40

±65

±50

±45

Backlight

Cold cathode rectifier (cannot be replaced by users)

Average Backlight Life*1
Backlight

Approx. 50,000 h

Auto OFF Function

Approx. 54,000 h

Approx. 58,000 h

Always ON, random setting

Contrast Adjustment

Provided *2

Not provided

Brightness Adjustment

128 levels

*3

Not provided

Surface Sheet

Material: Polycarbonate, 0.3 mm thick
Illuminated in green when the power is on;
illuminated in orange when the voltage of the battery (with its cable connected) has
become low.

POWER Lamp

Slide switch

MJ2 Function Selection

Down: RS-422 (4-wire)
Up:
RS-232C

*1 When the normal temperature is 25°C, and the surface luminance of the display is 50% of the initial
setting
*2 Adjustable with function switches
*3 By using the macro command

Touch Switch Specifications
Item

Specifications

Method

Analog resistance film type, matrix resistance film type

Switch Resolution

Analog: 1024 (W) × 1024 (H)
Matrix: 20 (W) × 12 (H)

Mechanical Life

One million activations or more

Surface Treatment

Hard-coated, anti-glare treatment 5%

Function Switch Specifications
Item

Specifications

Number of Switches

6

Method

Digital resistance film

Mechanical Life

One million activations or more

1. Specifications

2-3

Interface Specifications
Item

Specifications
RS-232C, RS-422/485 (2-wire connection)
UG00P-MR, Barcode, UG00P-U2, Multi-link 2,
Temperature control network/PLC2Way, UG-link, etc.

PLC Connection
Serial Interface
(Modular jack, 8-pin: MJ2)

RS-232C, RS-422 (4-wire connection)
Asynchronous type
Data length: 7, 8 bits
Parity:
Even, odd, none
Stop bit:
1, 2 bits
Baud Rate: 4800, 9600, 19200, 38400, 57600, 76800, 115200 bps

Printer/CF Card Reader Connection
USB Master Port (USB-A)

Type A, USB Ver. 1.1

Screen Data Transfer
USB Slave Port (USB-B)

Type B, USB Ver. 1.1

Clock and Backup Memory Specifications
Item

Specifications

Battery Specification

Coin-type lithium primary cell

Backup Memory

SRAM

Backup Time Period

5 years (ambient temperature at 25°C)

128 kbyte

Battery Voltage Drop Detection

Provided (internal memory allocated)

Calendar Accuracy

Monthly deviation ±90 sec (ambient temperature at 25°C)

Drawing Environment
Item

Specifications

Drawing Method

Exclusive drawing software

Drawing Tool

Name of exclusive configuration software: UG00S-CW (Ver. 3.2.0.0 and later)
Personal computer:
Pentium II 450 MHz or above
recommended
OS:
Windows98/Me/NT Ver.4.0/2000/XP
Capacity of hard disk required:
Free space of approx. 460 Mbyte or more
(For minimum installation:
approx. 105 Mbyte)
Display:
Resolution 800 × 600 or above
recommended

2
Specifications

Screen Data Transfer/External
Connection
Serial Interface
(Modular jack, 8-pin: MJ1)

2-4

1. Specifications

Display Function Specifications
Item
Display Language*
1/4-size, 1-byte
Characters

Specifications
USEnglish

English/Western
Europe

Chinese
(traditional)

Chinese
(simplified)

Korean

ANK code

Latin1

ASCII code

ASCII code

ASCII code

−

Chinese
(traditional)

Chinese
(simplified)

Hangul
(without Kanji)

−

−

−

2-byte 16-dot

JIS #1, 2 levels

2-byte 32-dot

JIS #1 level

Character Size

Number of Displayable
Characters

−
1/4-size:
1-byte:
2-byte:
Enlarge:

8 × 8 dots
8 × 16 dots
16 × 16 dots or 32 × 32 dots
W: 1 to 8 times, H: 1 to 8 times

Resolution

320 × 240

1/4-size

40 characters × 30 lines

1-byte

40 characters × 15 lines

2-byte

20 characters × 15 lines

Characters Properties

Display properties:
Colors:

Normal, reverse, blink, bold, shadow
32,768 colors + blink 16 colors / monochrome 8-grade + blink

Graphics

Lines:
Circles:
Others:

Line, continuous line, box, parallelogram, polygon
Circle, arc, sector, ellipse, elliptical arc
Tile patterns

Graphic Properties

Line types:
Tile patterns:
Display properties:
Colors:
Color selection:

6 (thin, thick, dot, chain, broken, two-dot chain)
16 (incl. user-definable 8 patterns)
Normal, reverse, blink
32,768 colors + blink 16 colors / monochrome 8-grade + blink
Foreground, background, boundary (line)

* In addition, the following fonts are available. For more information, refer to the User’s Manual 
(FEH375) and the User’s Manual  (FEH376-1).
Gothic, English/Western Europe (HK Gothic), English/Western Europe (HK Times), Central Europe, Cyrillic,
Greek, Turkish

1. Specifications

2-5

Function Performance Specifications
Item

Specifications

Screens

Max. 1024

Screen Memory

Flash memory: Appox. 1,472 kbyte (varies depending on the font)
192 per screen

Switch Actions

Set, reset, momentary, alternate, to light
(Possible to press a function switch and a switch on the display at the same time)
(Matrix type: Possible to press two switches on the display at the same time)

Lamps

Reverse, blink, exchange of graphics
192 per screen

Graphs

Pie, bar, panel meter and closed area graph: No limitation within 256 kbyte per screen*1
Statistics and trend graphs:
Max. 256 per layer*2

Data
Setting

Numerical Data Display

No limitation within 256 kbyte per screen*1

Character Display

No limitation within 256 kbyte per screen*1

Message Display

Resolution:

Max. 40 1-byte characters

No limitation within 256 kbyte per screen*1
Sampling display of buffer data
(Constant sample, bit synchronize, bit sample, relay sample, alarm function)

Sampling
Graphic Library

Max. 2560

Multi-Overlaps

Max. 1024

Data Blocks

Max. 1024

Messages

Max. 6144 lines

Patterns

Max. 1024

Macro Blocks

Max. 1024

Page Blocks

Max. 1024

Direct Blocks

Max. 1024

Screen Blocks

Max. 1024

Data Sheets

Max. 1024

Screen Library

Max. 1024

Temperature Control Network/
PLC2Way Table

Max. 32

Time Display

Time display function: provided

Hard Copy

Screen hard copy function: provided

Buzzer

Buzzer: provided, 2 sounds (short beep, long beep)

Auto OFF Function

Always ON, random setting

Self-diagnostic Function

Switch self-test function
Communication parameter setting check function
Communication check function

*1
*2

The number of setting memory locations is limited to 256 per screen.
Layer: 4 per screen (base + 3 overlaps)

Specifications

Switches

2

2-6

2.

2. Dimensions and Panel Cut-out

Dimensions and Panel Cut-out

UG230 External View and Dimensions
(Unit: mm)
• Front View

• Side View
• Rear View

• Bottom View

• Panel Cut-out Dimensions

2. Dimensions and Panel Cut-out

2-7

UG230 + UG230A-DCL External View and Dimensions
(Unit: mm)

2

• Front View

Specifications

• Side View
• Rear View

• Bottom View
• Panel Cut-out Dimensions

2-8

3.

3. Names and Functions of Components

Names and Functions of Components

UG230

UG230+UG230A-DCL

1. Display
This is the display unit.
2. Power lamp (POWER)
Illuminates (green) when the power is supplied. The lamp illuminates (orange) when the voltage of
the battery set in the POD has become low.
3. Function switches
Used for RUN /STOP selection, contrast adjustment, brightness adjustment and backlight ON/OFF
(according to the setting). These switches can be used as user switches in the RUN mode.

3. Names and Functions of Components

2-9

4. Option unit connector (CN1)
This is the connector where the option unit UG230A-DCL is mounted.
5. Battery holder
Contains a backup battery for SRAM and clock.
When the battery voltage drops, replace the battery with a new one (UG30P-BT).

7. Modular jack connectors (MJ2)
This is used for connection with the PLC.
With the option unit UG230A-DCL mounted, the modular jack allows you to connect a barcode
reader, serial printer, etc.
8. USB-B (slave port)
This is the connector for screen data transfer.
9. USB-A (master port)
This is the connector where a printer or a CF card reader/writer is connected.
10. Power supply terminal block
Supplies the power (24 VDC) to the UG230.
11. Mounting holes
Used for inserting fixtures when securing the POD to the mounting panel.
12. DIP switch
This is used for setting the terminating resistors of the MJ1/MJ2 RS-422/485 signal line.
13. Slide switch
This is used for switching between the RS-232C and RS-422 ports for the MJ2.
14. Add-on memory connector (MEMORY) (optional)
With the option unit UG230A-DCL mounted, this is used for mounting an optional FLASH memory
cassette (UG230P-D4).
15. PLC communication connector (CN1) (optional)
With the option unit UG230A-DCL mounted, this is used for connecting the UG230 and a PLC or
an external control unit (computer, custom controller, etc.).
16. CF card connector (CF) (optional)
This is the connector where the CF card is inserted when the option unit UG230A-DCL is installed.
17. 10BASE-T connector (LAN) (optional)
With the option unit UG230A-DCL mounted, this is used for Ethernet connection.

2
Specifications

6. Modular jack connector (MJ1)
This is used for screen data transfer and connection with temperature controller, barcode reader,
UG00P-MR, etc.

2-10

4.

4. Modular Jack (MJ1/MJ2)

Modular Jack (MJ1/MJ2)

Modular Jack 1 (MJ1)
This is a modular connector used for connection for screen data transfer, temperature controller,
barcode reader, card recorder (UG00P-MR) or serial extension I/O (UG00P-U2).
Bottom View

The pins of modular jack 1 correspond to signals as given below.
MJ1

Pin No.

Signal Name

Contents

1

+SD/RD

RS-485 +data

2

−SD/RD

RS-485 − data

3

+5V

4

+5V

Externally supplied +5 V
Max. 150 mA*

5

SG

6

SG

7

RD

RS-232C receive data

8

SD

RS-232C send data

12345678

Signal ground

* The maximum current for external supply (+5V) is 150 mA when the MJ1 or MJ2 is used.

Editor (UG00S-CW) Setting
1. The use of modular jack 1 can be set on the editor.
2. Select [Modular] from the [System Setting] menu. The [Modular Jack] dialog is displayed. Select
the use of modular jack 1 from the following options.
Modular Jack 1
[Editor Port]*1
[Card Recorder]*2
[Barcode]*3
[UG00P-U2]
[Multi-Link]*4
[Temp. /PLC2Way]
[UG-Link]
[Ladder Tool]*5
[Modbus Slave]*6
[Printer (Serial Port)]*7
*1
*2
*3
*4
*5
*6
*7

Refer to “Transferring Screen Data” (page 2-17).
Select this option when connecting the card recorder (UG00P-MR).
Refer to “Barcode Reader Connection” (page 2-17).
Select this open when “Multi-link 2” is selected for [Connection] and “1” is set for [Local Port] on the
[Comm. Parameter] dialog.
Select this option when using the ladder transfer function.
Select this option for Modbus slave connection.
Select this option when connecting the printer with serial interface.
Refer to page 2-18.

4. Modular Jack (MJ1/MJ2)

2-11

Modular Jack 2 (MJ2: Exclusive to the UG230)

CAUTION

Before using the MJ2, select whether it is used as an RS-232C or RS-422 port using the
slide switch.
The switch is factory-set to RS-422.

Specifications

This is a modular jack connector used for connection with the PLC.
Unlike the MJ1, the connector is available as an RS-422 (4-wire) port.
Bottom View

The pins of modular jack 2 correspond to signals as given below.
MJ2

Pin No.
1

*1

2

*1

12345678

3
4
5
6

*1
*2

7

*1

8

*1

Signal Name

Contents

Not used

Not used

+SD

RS-422 + send data

Not used

Not used

−SD

RS-422 −send data

+5V

Externally supplied +5 V
Max. 150 mA*2

SG

Signal ground

RD

RS-232C receive data

+RD

RS-422 + receive data

SD

RS-232C send data

−RD

RS-422 − receive data

Switch between RS-232C and RS-422 for pin Nos. 1, 2, 7, and 8 with the slide switch on the POD.
The maximum current for the output power supply (+5 V) is 150 mA when MJ1 or MJ2 is used.

Without the Option Unit UG230A-DCL
The MJ2 is usable as a port for PLC connection.

Slide switch
• Use the switch to set the signal level for the MJ2.
Side View

Slide switch
Lower position: RS-422 (4-wire)
Upper position: RS-232C

Wiring
For more information, refer to page 2-14.

2

2-12

4. Modular Jack (MJ1/MJ2)

Unusable PLC models
The following PLC models cannot be connected to the MJ2.
Manufacturer

PLC
A Series CPU

Mitsubishi
Hitachi

FX Series CPU
(however, can be used with FX0N tool port)
HIDIC H-series RS-232C
S7-300MPI (HMI ADP)

Siemens

S7-300MPI (PC ADP)
S7-300MPI (Helmholz SSW7 ADP)

When connecting any of the above PLCs, be sure to mount the option unit UG230A-DCL and connect
the PLC to the D-sub 25-pin connector of the unit.

Editor (UG00S-CW) Setting
When “None” is chosen for [Option Unit] on the editor, modular jack 2 is automatically used as a PLC
port.
* When “None” is chosen for [Option Unit] and “Not connect PLC” is chosen for [PLC Type], MJ2
becomes usable as when a type is chosen for [Option Unit].

Combination of MJ1 and MJ2 functions
When “Not connect PLC” is chosen for [PLC Type], both MJ1 and MJ2 become usable as when a type
is chosen for [Option Unit]. Page 2-13 shows usable combination of functions.

With the Option Unit UG230A-DCL
MJ2 is used to connect a temperature controller or a barcode reader. Since MJ2 is also available as
an RS-422 (4-wire) port, it differs from MJ1 in some respects.

Slide switch
• Use the switch to set the signal level for the MJ2.
Side View

Slide switch
Lower position: RS-422 (4-wire)
Upper position: RS-232C

• Functions used with RS-232C
Barcode reader, ladder tool (ladder transfer), printer (serial port)
• Functions used with RS-422
Multi-link 2
• Functions used with either RS-232C or RS-422 depending on the devices to be connected or
connecting methods
Temperature controller/PLC2Way, UG-Link, Modbus slave communication

Wiring
For more information, refer to page 2-16.

4. Modular Jack (MJ1/MJ2)

2-13

Editor (UG00S-CW) Setting
1. The use of modular jack 2 can be set on the editor.
2. Select [Modular] from the [System Setting] menu. The [Modular Jack] dialog is displayed. Select
the use of modular jack 2 from the following options.
Modular Jack 2

2

[Not Used]

Specifications

[Barcode]
[Multi-Link]
[Temp. /PLC2Way]
[UG-Link]
[Ladder Tool]
[Modbus Slave]
[Printer (Serial Port)]

Combination of MJ1 and MJ2 functions
: Usable at the same time.
MJ1
MJ2
MultiLink 2

Barcode
Temp./
PLC2Way
UG-Link

Ladder
Tool
Modbus
Slave
Printer
(Serial Port)

MultiLink 2

Card
Recorder

Barcode

UG00P-U2

Temp./
PLC2Way

UG-Link

Ladder
Tool

: Not usable at the same time
Modbus
Slave

Printer
(Serial Port)

2-14

4. Modular Jack (MJ1/MJ2)

Notes on Wiring
Notes on the Use of MJ1/MJ2

CAUTION

The metal shell of the UG230 modular jack is used as SG (signal ground).
Fuji’s communication cable for modular jack, shielded cable, is connected to the SG
inside the UG230.

Notes on the Use of MJ2
Either the RS-232C or RS-422 port can be selected for MJ2 with the slide switch.
When the slide switch is set to RS-232C, MJ2 is connected in the same manner as MJ1.
When the slide switch is set to RS-422, extra care should be taken if connecting a device adapted to
RS-485 (2-wire).

PLC connection
There are two connecting methods.
One method uses an adaptor UG30C-J for connection between MJ2 and the D-sub 25-pin connector
plus a PLC communication cable (as shown in the User’s Manual  (FEH380)).
The other method uses a UG00C-P cable for connection between MJ2 and a PLC interface cable.
For information on the PLC wiring diagram, refer to the separate User’s Manual 
(FEH380).
• Connecting to an RS-232C port (example: Mitsubishi A1SJ71UC24-R2):
POD PLC communication cable

With UG30C-J
D-sub 25-pin (Male)

FG

1

PLC
D-sub 9-pin (Male)

UG30C-J
SD

2

CD

1

RD

3

RD

2

RS

4

SD

3

CS

5

SG

5

SG

7

DR

6

RS

7

CS

8

MJ2

With UG00C-P
MJ2
RJ-45 8-pin

SG SHELL

UG00C-P
PLC
D-sub 9-pin (Male)

SD

8

CD

1

RD

7

RD

2

SG

5

SD

3

SG

5

DR

6

RS

7

CS

8

2-15

4. Modular Jack (MJ1/MJ2)

• Connecting to an RS-422 port (example: Mitsubishi QJ71C24):
POD PLC communication cable
With UG30C-J
D-sub 25-pin (Male)

FG

1

PLC

2

UG30C-J
SG

7

SDA

+SD

12

SDB

MJ2

13

RDA

24

RDB

-RD

25

SG

With UG00C-P
MJ2
RJ-45 8-pin

UG00C-P

SG SHELL

PLC

SG

5

SDA

+SD

1

SDB

-SD

2

RDA

+RD

7

RDB

-RD

8

SG

* When connecting to a Mitsubishi QnA CPU port, a connection between MJ2 and the PLC can
be established by changing the PLC-side connecting method.
MJ2
RJ-45 8-pin

SG SHELL

UG00C-P

Mitsubishi QnA CPU
PLC
D-sub 25-pin (Male)

SG

5

2

+SD

1

3

+TxD

-SD

2

4

+DSR

+RD

7

5

+DTR

-RD

8

7

SG

15

-RxD

+RxD

16

-TxD

17

-DSR

18

-DTR

20
21

Specifications

-SD
+RD

2-16

4. Modular Jack (MJ1/MJ2)

• Connecting to an RS-485 port (example: Siemens S7-300 MPI port):
POD PLC communication cable
With UG30C-J

D-sub 25-pin (Male)

FG

1

+SD

12

+RD/SD

3

-SD

13

-RD/SD

8

+RD

24

-RD

25

PLC

UG30C-J
MJ2

With UG00C-P
MJ2
RJ-45 8-pin

UG00C-P
PLC

SG

SHELL

+SD

1

+RD/SD

3

-RD/SD

8

-SD

2

+RD

7

-RD

8

Temperature controller/PLC2Way/UG-Link/Modbus slave communication
For information on the wiring diagram, contact your local distributor.

4. Modular Jack (MJ1/MJ2)

2-17

Transferring Screen Data
• Use modular jack 1 (MJ1) when transferring screen data.

• When an option other than [Editor Port] is selected for [Modular Jack 1], select the STOP mode
(on the Main Menu screen) and transfer screen data. Simulation or on-line editing is not available.
• When transferring screen data, use Fuji’s data transfer cable (UG00C-T) 3 m to connect the
UG230 to a personal computer.

Barcode Reader Connection

• To connect a barcode reader to the modular jack
(MJ1/2), use Fuji’s optional cable (UG00C-B).
Length: 3 m
with modular plug
• Notes on connection
- In the case of barcode readers with CTS and
RTS control, it may be necessary to install a
jumper to RTS and CTS. Otherwise the
barcode reader may not work correctly.
- The external power supply (+5 V) is max. 150
mA.
(Refer to page 2-10.)

12345678

• It is possible to receive the signal from a barcode reader by connecting the barcode reader at the
modular jack (MJ1/2) of the UG230.

Brown:
Red:
Orange:
Yellow:

+5V
0V
RD
TD

12345678

• When using the barcode reader that was connected to UG400 (POD’s old version), connect it to
the D-sub 9-pin female connector using the UG00C-B cable as shown below.

Barcode reader

Signal

RTS
TXD
RXD
CTS
SG
+5V

D-sub 9-pin (female)

Pin No
1
2
3
4
5
6
7
8
9

Signal
Name

CS
RD
SD
RS

Orange: RD
Yellow: SD

* Install a jumper between
CTS and RTS.

SG
+5V

Red: 0 V
Brown: +5 V

2
Specifications

• When [Editor Port] is selected for [Modular Jack 1] on the editor, it is possible to transfer data in the
RUN mode because the RUN/STOP mode (on the Main Menu screen) can be automatically
selected.
Also RUN/STOP mode is automatically selected for on-line editing and simulation.

2-18

4. Modular Jack (MJ1/MJ2)

Printer Connection (Serial Printer)
• To connect a printer through serial interface, connect the cable to a modular jack (MJ1/MJ2).
• Refer to the specification sheet of the printer to be used for the connecting cable for serial
interface. For information on MJ1/MJ2 signals, refer to page 2-10.
• To connect to a printer equipped with a parallel interface, use a commercially available
parallel-serial converter.
When the serial connector of the converter is a D-sub 9-pin male connector, use Fuji’s UG00C-T
connection cable.
Printer
D-sub 25-pin ←→ 9-pin converter
UG230

Parallel port

UG00C-T

MJ

Parallel ←→ serial converter

Compatible Printer Models
Control code system:
• PR201
• ESC-P
Others
• CBM292/293
• MR400

• EPSON STYLUS PHOTO series

PC-PR201 series compatible with MS-DOS computer
ESC/P24-J84, ESC/P-J84, ESC/P super function compatible
with MS-DOS computer
CBM’s line thermal printer
(Screen hard copying is not possible.)
Sato’s barcode printer “MR400 series”
(It is not possible to print a screen hard copy, data sheet or
sampling data.)
EPSON color ink jet printer STYLUS PHOTO series
(For printer models, refer to the User’s Manual
 (FEH376-1).)

Screen Data Setting
From the [System Setting] menu, select [Printer Setting] and open the [Main] tab window.
• Type: (as desired)
• Port: Serial Port (MJ Port) → Go to the [Serial Port] tab window for communication setting.
↓
[Refer to Modular] button
↓
• Modular Jack 1 (or 2)
Printer (Serial Port)
Set the above options.

5. USB Connectors

5.

2-19

USB Connectors

2

USB-A (Master Port)
Bottom View

Specifications

Enlarged View

Available Devices
Printer
• EPSON color ink jet printer STYLUS PHOTO for USB port
* For more information, refer to User’s Manual  (FEH376-1).
• Printer with parallel interface
Printer models and available print functions are the same as those for a serial printer (page 2-18).

CF card reader/writer
Recommended models are:
Manufacturer

Type

I-O Data Device

USB-CFRW

TDK

U2RW03CF

ELECOM

MR-UCF1SV

Connecting Cable
• Use the cable included with the device to be connected (printer or CF card reader/writer).
Printer
USB cable
UG230

USB-B
USB-A

CF

96MB

RW

CF card reader/writer

2-20

5. USB Connectors

• To connect to a printer equipped with a parallel interface, use a commercially available parallel
←→ USB cable (ELECOM UC-PGT recommended).
Parallel ←→ USB cable

Printer
Parallel port

UG230

USB-A

Screen Data Setting
For a printer
From the [System Setting] menu, select [Printer Setting] and open the [Main] tab window.
• Type: (as desired)
• Port: USB Port

For CF card reader/writer
From the [System Setting] menu, select [Unit Setting], and open the [Option Unit] tab window.
• [ Use USB CF Card Reader]: checked

USB-B (Slave Port)
This is a connector for screen data transfer via USB.
Bottom View

Enlarged View

* When transferring screen data via the USB-B (USB slave port), be sure to install the USB driver for
POD on the computer. The steps are described in the following section “Installing the USB Slave
Driver.”
Screen data transfer via the USB port is available with Windows 98 Second Edition and later.

Connecting cable
Use a commercially available USB cable.
UG230

Computer

USB cable
disc

RESET

USB-B

USB-A

5. USB Connectors

2-21

Installing the USB Slave Driver
The installation procedure on Windows 2000 is described as an example below.
1. Connect the USB-B port of the UG230 (with power on) to the computer (with power on) using a
USB cable.

3. When the dialog box below is displayed, select [Display a list of the known drivers for this device
so that I can choose a specific driver] and click the [Next] button.

4. The dialog box below is displayed. Select [Other Devices] and click the [Next] button.

Specifications

2. The message “Found New Hardware” and then the driver installation wizard appear on the
computer. Click the [Next] button.

2

2-22

5. USB Connectors

5. The dialog box below is displayed. Click [Have Disk].

6. The [Install From Disk] dialog box is displayed. Click the [Browse] button.

7. The UG230 USB driver “OP-U.inf” is automatically stored in the “inf” folder within the UG00S-CW
editor installation folder (“UGW” for example).
Select the “OP-U.inf” file and click the [Open] button.

8. The previous dialog box is displayed again. Check the path shown under [Copy Manufacturer’s
Files From:] and click the [OK] button.

5. USB Connectors

2-23

9. The dialog box below is displayed. Check that [Operation Panel USB Driver] is shown under
[Models:]. Click the [Next] button.

2
Specifications

10. The driver installation starts.

11. The dialog box below is displayed on completion of installation. Click the [Finish] button.

2-24

5. USB Connectors

Recognition of USB Driver
When the driver has been installed successfully and the UG230 and the computer are connected with
a USB cable, the [Device Manager] window shows “Operation Panel - Operation Panel USB Driver.”

This will disappear when the UG230 and the computer are disconnected.
If [Other Device] or [?] is shown even while their connection via USB is maintained, the USB driver
may not be recognized. If this happens, uninstall the USB driver once and reinstall it.

6. D-sub 25-Pin Connector (CN1) (Optional)

6.

2-25

D-sub 25-Pin Connector (CN1) (Optional)

2

When the option unit UG230A-DCL is mounted, the CN1 connector is usable.

Serial Connector (CN1)

UG230A-DCL

The correspondence between the serial connector pins and signals is shown below. The interface is
the same as that for the UG30-series CN1.
CN1 (D-sub 25-pin, female)

Pin No.

Signal Name

Contents

1

FG

Frame ground

2

SD

RS-232C send data

3

RD

RS-232C receive data

4

RS

RS-232C RS request to send

5

CS

RS-232C CS clear to send

SG

Signal ground

9

+5V

Use prohibited

10

0V

Use prohibited

+SD

RS-422 send data (+)

6

1
14

7

Not used

8

Not used

11
12

Not used

13

−SD

RS-422 send data (−)

14

+RS

RS-422 RS send data (+)

15

25

17

13

Not used

16

Not used
−RS

RS-422 RS send data (−)

18

−CS

RS-422 CS receive data (−)

19

+CS

RS-422 CS receive data (+)

21

−

Use prohibited

22

−

Use prohibited

24

+RD

RS-422 receive data (+)

25

−RD

RS-422 receive data (−)

20

Not used

23

Not used

The following connector is recommended.
Recommended connector

DDK-make 17JE23250-02 (D8A)

D-sub 25-pin, male, metric thread, with hood

Specifications

To communicate with the PLC (RS-232C, RS-422/485), connect the cable to the serial connector
(CN1).

2-26

7.

7. 10BASE-T (LAN) (Optional)

10BASE-T (LAN) (Optional)
When the option unit UG230A-DCL is mounted, the 10BASE-T (LAN) connector is usable.

10BASE-T Connector
Use this connector for Ethernet connection.
Bottom View

CAUTION

UG230A-DCL

MJ1/2 and LAN connector are 8-pin modular jacks.
Check the name plate and insert the connector in the correct position.

The LAN (10BASE-T) pins correspond to signals as given below.
LAN

12345678

Pin No.

Signal Name

Contents

1

TX+

Ethernet send signal (+)

2

TX−

Ethernet send signal (−)

3

RX+

Ethernet receive signal (+)

4

NC

Not used

5

NC

Not used

6

RX−

Ethernet receive signal (−)

7

NC

Not used

8

NC

Not used

2-27

7. 10BASE-T (LAN) (Optional)

Notes on Wiring
When using the LAN port, keep the LAN cable away from the power supply cable as
much as possible.

CAUTION

Specifications

HUB

UTP cable
Straight or cross cable
(For more information, refer
the HUB specifications.)

UTP cable
Straight

UG230A-DCL

PLC

Ethernet
Unit

UG230

UG30
highperformance
type

HUB
Node

Distance between the node and the HUB: 100 m maximum
Maximum network nodes:
100

Node

Cable Connection Diagram
Straight
(with HUB)

Cross
(without HUB)

10BASE-T
RJ-45 8Pin

10BASE-T
RJ-45 8Pin

10BASE-T
RJ-45 8Pin

10BASE-T
RJ-45 8Pin

1

1

1

3

2

2

2

6

3

3

3

1

6

6

6

2

4

4

4

5

5

5

5

4

7

7

7

8

8

8

8

7

* Unshielded twist-pair cable

* Unshielded twist-pair cable

Notes on Cables
Use the following recommended cable.
Recommended cable

10BASE-T

2

Type: Twist-pair cable, category 5

2-28

8.

8. CF Card

CF Card

Recommended CF Cards
CF cards in compliance with CompactFlashTM can be used.
The operation of the following cards has been verified by us.
Manufacturer
Kodak

Type

Capacity

KPCN-32

SanDisk

32 MB

SDCFB-64-505

64 MB

SDCFB-xxxx-801

32 MB
64 MB
96 MB
128 MB
192 MB
256 MB
384 MB
512 MB
1 GB

CFS-32MA

32 MB

CFS-xxM(HI)

32 MB
64 MB
128 MB
256 MB
512 MB

CFS-iVxxx

32 MB
64 MB
128 MB
256 MB
512 MB

I-O Data Device

Hagiwara Sys-Com
Melco

HPC-CFxxZX

32 MB

RCF-XX

64 MB
128 MB
256 MB
512 MB

CF Card Insertion Position
With the USB port:
The following items are recommended.
Manufacturer

USB-CFRW

TDK

U2RW03CF

ELECOM

MR-UCF1SV

DAZZLE

DM-8000

CF

96MB

Type

I-O Data Device

RW

USB-A

8. CF Card

2-29

With the option unit:
Insert a CF card into the CF connector of the option unit UG230A-DCL.
UG230A-DCL

2
Specifications

Mounting and Dismounting the CF Card
With the USB port:
Follow the instructions provided in the CF card reader/writer manual.

With the option unit:
1. Insert the card securely into the interface with the card backside outwards viewed from the rear of
the unit as shown below.

Card backside

When the card is inserted,
the eject button pops out.

2. To remove the card, press the eject button. The card pops out.

2.

2-30

8. CF Card

Notes on Handling the CF Card
1. POD can recognize a CF card in the FAT file system. It cannot recognize a FAT32-formatted CF
card.
2. Do not insert or remove the CF card during access. Doing so may destroy data on the CF card.
The CF card can be inserted or removed safely when the Main Menu screen is displayed. Before
mounting or removing the CF card, be sure to check that the CF card is not being accessed.
Doing so may destroy data on the CF card or cause CF card failure.
However, if the [Card Menu] switch is pressed on the Main Menu screen and the CF card
operation screen is displayed, it is not possible to insert or remove the CF card.
3. Do not turn the power off or on during access to the CF card.
4. Make a backup copy of the CF card at regular intervals.
5. If there should be a disk error and you cannot read/write data, you can scan the disk in Windows to
restore the disk data.
If not restored, initialize the CF card. Note that the data in the CF card will be completely deleted
by initialization. (For more information on scanning the disk or operating Windows, refer to the
Windows manual.)
6. The number of writing times per CF card is limited (approx. 300,000 times).
Consequently, frequent writing at short intervals may shorten service life of the CF card. When
using a CF card to save sampling data, be aware of the sampling time. Be sure to always avoid
writing to a CF card with the CYCLE macro command.

3

Installation

1.

Mounting Procedure

2.

Power Supply Cable Connection

3-1

1. Mounting Procedure

1.

Mounting Procedure

Mounting Procedure
1. Insert the UG230 into the mounting panel (max. thick: 5 mm).

3

Mounting panel
Panel cut-out hole

Installation

• Panel cut-out dimensions
(Unit: mm)

2. Insert four fixtures attached to the UG230 into the mounting holes, and tighten them with the
locking screws.
Tightening Torque: 0.3 to 0.5 N•m
Fixtures
Mounting hole

Fixture dimensions
(Unit: mm)

Mounting hole
UG230

10.5
30
.0

Mounting
panel

17.8

* To prevent static electricity, be sure to
connect the mounting panel to the ground.

Fixtures

3. Mount the gasket so that it will be sandwiched securely between the unit and the mounting panel.

Mounting Angle
90°
Install the unit within the angle of 0° to 135° as shown on the right.

135°
D
is
pl
ay

Display

0°

3-2

2.

2. Power Supply Cable Connection

Power Supply Cable Connection

DANGER

Electric shock hazard
Shut the power off before connecting the power supply cable.

Power Supply Cable Connection
• Connect the power supply cable to the terminal on the backside of the unit.
24 VDC

24 VDC

Grounding
Power supply
24 VDC ± 10%

• Tighten terminal screws on the power supply terminal block with the following torque.
Terminal Screw

•
•
•
•
•

Screw Size

Tightening
Torque

M3.5

0.5 N•m

Crimp-style Terminal (Unit: mm)
7.1 MAX

7.1 MAX

The power source must be within the allowable voltage fluctuation.
Use a power source with low noise between the cables or between the ground and the cable.
Use as thick a power supply cable as possible to minimize drop in voltage.
Keep power supply cables away from high-voltage, large-current carrying cables.
Be sure to attach the terminal cover to the terminal block.
Terminal cover

2. Power Supply Cable Connection

3-3

Grounding

CAUTION

Be sure to establish a ground of POD.
(The level of grounding resistance should be less than 100 Ω.)

POD

Other
equipment

3
Installation

• An independent earth pole must be used for POD.
• Use a cable which has a nominal cross section of more than
2 mm2 for grounding.
• Set the grounding point near the POD to shorten the distance
of grounding cables.

3-4

2. Power Supply Cable Connection

Please use this page freely.

4

Instructions

1.

Coin-type Lithium Battery

2.

DIP Switch Setting

3.

Function Switches

1. Coin-type Lithium Battery

1.

4-1

Coin-type Lithium Battery

CAUTION

The POD is delivered without inserting the battery connector in the battery holder on the
back of the unit.
Be sure to set the battery when using the calendar function or SRAM.
Without battery, the contents in the SRAM or calendar will not be retained.

Battery Mounting Procedure

Electric shock hazard
Steps 2 to 5 must be performed when the power to the POD is turned off.

1. Turn the unit off.
2. Slide the battery holder cover in the direction of the arrow (“→” shown below) to open it.

See operating or maintenance
instruction for type of battery
to be used.

Battery replacement.

Slide and open.

See operating or maintenance
instruction for type of battery
to be used.

See operating or maintenance
instruction for type of battery
to be used.

Battery replacement.

Battery replacement.

3. Check that the battery is securely attached to the backside of the cover, and connect the battery
connector.

Battery connector

4. Close the battery holder cover. When closing the cover, slide it in the direction of the arrow (“←“
shown below) to lock it.
Slide and lock.

See operating or maintenance
instruction for type of battery
to be used.

See operating or maintenance
instruction for type of battery
to be used.

Battery replacement.

Battery replacement.

Instructions

DANGER

4

4-2

1. Coin-type Lithium Battery

5. Enter a date five years from now for “Battery Replacement”
on the sticker on the battery holder.
See operating or maintenance
instruction for type of battery
to be used.

* The battery status is output to the internal memory
$s167 of the UG230.
If the battery voltage drops before five years has
elapsed, replace the battery immediately.

Battery replacement.

Enter a date five years from now
MSB

LSB

15

14

13

12

11

10

09

08

07

06

0

0

0

0

0

0

0

0

0

0

05

04

03

02

01

00

$s167
0

Memory cassette information
reserved (Setting: 0)

0:
1:
2:
3:
4:

0: The battery is normal.
1: Battery voltage drop
2: Battery not mounted

Not mounted
FROM 2 Mbyte (UG20)
FROM 4 Mbyte (UG230/UG20)
SRAM 512 kbyte (UG30/UG20)
FROM 8 Mbyte (UG30)

Memory cassette information reserved (Setting: 0)

6. Turn on the power to the UG230 and check that the
battery is correctly mounted on the Main Menu
screen.
When the battery is not connected, the [SRAM/Clock]
switch blinks and the message “Battery not set” is
displayed at the bottom left corner. When the battery
is correctly connected, the [SRAM/Clock] switch goes
out and the message is cleared.
When the battery voltage has dropped, the message
“Brownout Battery” is displayed.

Main Menu screen

Battery Replacement
Safety Instructions on Handling the Battery
Lithium batteries contain combustible material such as lithium or organic solvent. Mishandling may
cause heat, explosion or ignition resulting in fire or injury. To prevent accidents, pay attention to the
following cautions when handling the lithium battery.

CAUTION

•
•
•
•
•
•
•
•

Be sure to discharge static electricity from your body before battery replacement.
Use the battery “UG30P-BT” (replacement battery for the UG30) for replacement.
Rough handling of the battery may cause a fire or chemical burn hazard.
Do not disassemble, incinerate or heat the battery.
Observe the local and governmental regulations when disposing of waste batteries.
Keep batteries out of reach of children (If swallowed, immediately consult a doctor.)
Never re-charge the battery.
When the battery leaks or smells, the leaking battery electrolyte may catch a fire.
Keep from heat or flame.

4-3

1. Coin-type Lithium Battery

Battery Replacement Procedure
Replacement batteries are available from us.
Name
Replacement battery for the UG30

Type
UG30P-BT

Contents
• Coin-type lithium primary cell 1 pce
• Cautions sticker
1 pce

1. Replace the battery “UG30P-BT” within three minutes after the unit is turned off.
If it is not possible to replace within three minutes, use the UG00S-CW editor (cable: UG00C-T) or
a CF card and make a backup copy of data in the SRAM.
• When using the UG00S-CW editor:

4

1) Start the UG00S-CW editor.
2) Click the [Transfer] icon. The [Transfer] dialog is displayed.

4) Click the [PC <-] under [Transfer Mode].
5) Save the read data in the “∗.RAM” file.
• When using a CF card:
For the backup procedure with a CF card, refer to “Chapter 6 POD Operations.”
2. Turn the unit off. Slide and open the battery holder. The battery in the socket will come into view.
3. Unplug the battery connector, and remove the battery from the
socket. Take out the battery while pressing the center of the
battery holder cover as shown in the figure.

See op
era
instructi ting or ma
int
on
to be for type of enance
used.
battery
Battery

replac

emen

t.

4. Set a new battery. Fit the battery into the socket in such a
manner that the red cable side of the battery faces the board
and the cable faces out. Insert the battery in the “a” side first,
and push it down to “a” while inserted in the “b” side.

Battery holder
“b” side
“a” side

5. Plug in the battery connector and slide and lock the battery
holder cover.
6. Remove the existing caution sticker. Enter a date five years
from now for “Battery Replacement” on the new caution sticker,
and attach it to the backside of the unit.
7. When the backup copy of the SRAM data has been saved in
step 1, turn on the unit and load the data to the unit.

Printed circuit
board

Battery
connector

Socket

Instructions

3) Select [Display] for [Transfer Device] and [SRAM Data] for [Transfer Data].
To save a backup copy from the UG00S-CW editor on the server via Ethernet, check
[ Transfer through Ethernet/IP Address of the UG30 Equipped with SRAM]. Keep [
Use Simulator] and [ Read Comments in Data Transfer] unchecked.

4-4

2.

2. DIP Switch Setting

DIP Switch Setting

DIP Switch (DIPSW) Setting
When setting the DIP switch, turn the power off.
Side View

DIP switch

MJ1 (modular jack 1) terminating resistance for RS-485
MJ2 (modular jack 2) SD terminating resistance for RS-422
MJ2 (modular jack 2) RD terminating resistance for RS-422
CF auto load (for USB/UG230A-DCL)

1

2

3

4
ON

Terminating Resistance Setting (DIPSW1, 2, 3)
Set the terminating resistance for RS-422/485 connection.
• MJ1 can be used for RS-232C or RS-485 (2-wire) connection.
For the following connections, set DIPSW 1 to the ON position.
- Master station for multi-link 2 connection
- Temperature controller network/PLC2Way connection via RS-485
- Card Recorder: Connection with the UG00P-MR (optional)
- Serial extension I/O: Connection with the UG00P-U2 (optional)
- Connection to the UG230 at the termination of UG-link connection via RS-485
• MJ2 can be used for RS-232C or RS-422 (4-wire) connection.
- For connection to the PLC through the RS-422 interface (4-wire connection) at MJ2, set
DIPSW2 and 3 to the ON position.
- For connection to the PLC through the RS-422 interface (2-wire connection) at MJ2, set
DIPSW3 to the ON position.

CF Auto Load (DIPSW4)
A screen data file saved on a CF card can be auto-loaded as described below.
1. Transfer screen data from the computer to a CF card. (Refer to the User's Manual 
(FEH376) for more information.)
2. Set DIPSW4 in the ON position, and insert the CF card that contains the screen data file.
3. Turn the unit on. The screen data is automatically loaded into the FLASH memory of the unit.

3. Function Switches

3.

4-5

Function Switches

Types
• There are six function switches provided.
[SYSTEM], [F1], [F2], [F3], [F4], [F5]

[SYSTEM] Switch

Function switches for switch
menu selection

User-defined function
switches

User-defined
function switches

S
Y
S

M
O
D
E
BR

BR

BR

B
K
L
T

For UG230H-TS4:

For UG230H-SS/LS:

S
Y
S

S
Y
S

M
O
D
E

M
O
D
E

BR

CT

BR

CT

BR

CT

B
K
L
T

B
K
L
T

4
Instructions

The [SYSTEM] switch works in “alternate” operations.
When this switch is pressed once, the switch menu is displayed at the side of the function switches
[F1] to [F5], and each function switch corresponds to the menu item displayed in the switch menu.
When the [SYSTEM] switch is pressed again, the switch menu disappears, and the function switches
[F1] to [F5] work as defined by the user (page 4-6).

4-6

3. Function Switches

User-defined Function Switches [F1] to [F5]
• When the UG230 is in the STOP mode, the function switches do not work.
• When the UG230 is in the RUN mode and the switch menu by the [SYSTEM] switch is not
displayed, the function switches can be defined by the user.
• User-defined function switches should be set in the following dialogs of the UG00S-CW editor.
- Settings for each screen
[Edit] → [Local Function Switch Setting] → [Function Switch Setting] dialog
- Setting for all screens
[System Setting] → [Function Switch Setting] → [Function Switch Setting] dialog

[F1] to [F5] Switch Functions with Switch Menu
Functions
F1

Mode

Contents
Selects the operation mode between STOP ↔ RUN.
Contrast Adjustment
Item

F2
F3
F4

Contrast
Brightness

Brightness Adjustment

Adjust the contrast. Holding down the
switch for one second or more changes the
contrast rapidly.

Applicable
models

Adjusts the screen brightness in three
levels.

UG230H-SS/LS

UG230H-TS

F2

F3

F4

F2

Dark

Medium

Pale

1
Bright

Adjustment

F3*1
2
Medium

F4*1
3
Dark

Turn the backlight on and off.
Backlight control should be set on the UG00S-CW editor.
([System Setting] → [Unit Setting] → [Unit Setting] dialog, [Backlight] tab window)
Always ON
Ignored

F5

Backlight

*1

Auto 1/Auto 2/Auto 3

Manual/Manual 2

• The [F5] switch turns the backlight off.
• This is valid when the backlight control
bit (bit 11) in the read area “n + 1” in the
system memory is reset (OFF: 0).

• Manual
The [F5] switch turns the backlight off.
To turn it on, press somewhere on the
screen or a function switch.
• Manual 2
The [F5] switch turns the backlight on
and off.
• [Backlight Power ON Time Control] that
determines the backlight status at
power-up becomes valid.
When the power is turned on:
ON → Backlight ON
OFF → Backlight OFF

When a medium or dark brightness is set, the backlight service life may become shorter.

5

Connections

1.

1 : 1 Connection

2.

1 : n Connection (Multi-drop)

3.

n : 1 Connection (Multi-link 2)

4.

n : 1 Connection (Multi-link)

5.

Universal Serial Communications

6.

UG-Link

7.

PLC2Way

8.

Temperature Control Network

9.

Ethernet

1. 1 : 1 Connection

1.

5-1

1 : 1 Connection
• One set of the UG230 is connected to one PLC (1 : 1 connection).
[UG230 only]

PLC
UG230
...
...
...
...

RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

MJ2

RS-232C or RS-422 (RS-485)

5

[UG230 + UG230A-DCL]

PLC
UG230
...
...
...
...

RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

RS-232C or RS-422 (RS-485)

• The host link unit of the PLC or the CPU port is used and the UG230 (master station) establishes
communications according to the protocol of the PLC. Consequently, it is not necessary to have
the dedicated communication program on the PLC (slave station). The UG230 reads the PLC
memory for screen display. It is also possible to write switch data or numerical data entered
through the keypad directly to the PLC memory.

PLC
UG230

Read
RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

...
...
...
...

Write

• For more information on wiring and communication settings, refer to the User’s Manual  (FEH380).

Connections

CN1

5-2

2.

2. 1 : n Connection (Multi-drop)

1 : n Connection (Multi-drop)
One UG230 is connected to multiple PLCs. (Maximum connectable PLCs: 32)
UG230
* In the case of UG230 + UG230A-DCL, connect to “CN1”.

Maximum length (UG230 to the terminating PLC) = 500 m
RS-422/RS-485 connection

MJ2 *

RUN
STOP

...
...
...
...

...
...
...
...

PLC1

...
...
...
...

...
...
...
...

RUN
STOP

...
...
...
...

...
...
...
...

PLC2

...
...
...
...

...
...
...
...

RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

PLC3

...
...
...
...

RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

...
...
...
...

(n = 1~to32)
32)
PLCn (n=1

• For more information on wiring and communication settings, refer to the User’s Manual  (FEH380).

5-3

3. n : 1 Connection (Multi-link 2)

3.

n : 1 Connection (Multi-link 2)
• One PLC is connected to a maximum of four UG230 units.
• An original network is created where the UG230 (Local Port 1) that is directly connected to the
PLC is the master station, and other three UG230 are slave stations. Only the master station
makes communications directly with the PLC, and the slave stations make communications with
the PLC via the master station.
UG230 master

UG230 slave

UG230 slave

UG230 slave

Local port
1

Local port
2

Local port
3

Local port
4

* MJ2

MJ2 *

MJ1
Terminal block

Fuji’s cable
“UG00C-H” (3 m)
RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

Terminal block

MJ2 *
Terminal block

RS-485 connection

...
...
...
...

* In the case of UG230 + UG230A-DCL, connect to “CN1”.

PLC

• Communications between the UG230 master station and the PLC depend on the communication
speed set on the PLC. The maximum available speed for the UG230 is 115 kbps, which is higher
than the one available with multi-link connection described in “4. n : 1 Connection (Multi-link).”
• This multi-link connection is available with almost all the PLC models that support 1 : 1 connection.
(The connection between the master station and the PLC is the same as the one for 1 : 1
connection.)
• Use the RS-485 2-wire connection between stations of the UG230. Please use Fuji’s multi-link 2
master cable (UG00C-H) for connection between the master station (local port 1) and the slave
station (local port 2).
• The UG230, UG30 series and UG20 series can be used together. The UG20 series can be the
master station.
(However, when UG220/UG221 is the master station, the slave station must be UG220/UG221.
Also, depending on the hardware version of the UG20 series, multi-link 2 connection may not be
supported. Refer to the User’s Manual  (FEH352).
• For more information on wiring and communication settings, refer to the User’s Manual  (FEH380).

5
Connections

RS-232C
RS-422
RS-485

MJ2 *

5-4

4.

4. n : 1 Connection (Multi-link)

n : 1 Connection (Multi-link)
• One PLC is connected to multiple UG230 units. (Maximum connectable units: 32)
UG230 1

UG230 2

MJ2 *
Terminal block

UG230 3

MJ2 *
Terminal block

UG230 n (n = 1 to 32)

MJ2 *
Terminal block

MJ2 *
Terminal block

* In the case of UG230 + UG230A-DCL,
connect to “CN1”.

RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

...
...
...
...

Maximum length (PLC to the terminating UG230) = 500 m
RS-422/RS-485 connection

PLC

• The PLC must be of the type of signal level RS422/RS485 with port numbers.
RS422 connection between the UG230 ↔ PLC must be in 2-wire connection.
• The UG230, UG30 series and UG20 series can be used together.
• For more information on wiring and communication settings, refer to the User’s Manual  (FEH380).

5. Universal Serial Communications

5.

5-5

Universal Serial Communications
• A general purpose computer or an ASCII unit of the PLC (master station) controls the POD (slave
station) using dedicated commands.
Dedicated commands
Read

General-purpose
computer

UG230

disc

Write

MJ2

RESET

Interrupt

5

RS-232C or RS-422 (RS-485)

• For 1 : 1 connection, the UG230 can send an interrupt to the master station through switch
activation, write command from the keypad, and screen change.
• Use MJ2 (or CN1 when the UG230A-DCL is provided) of the UG230 for connection with a
general-purpose computer. Either signal level RS-232C or RS-422 (RS-485) can be selected.
• In addition to 1 : 1 connection, 1 : n connection is available between the general-purpose
computer and the UG230 via RS-422.
(A maximum of 32 UG230 units can be connected.)
For 1 : n connection, interrupts cannot be used.
General-purpose computer

disc

RESET

RS-422 (RS-485) connection

MJ2

MJ2

MJ2

UG230 1

UG230 2

UG230 3

MJ2

UG230 n (n = 1 to 32)

• For more information, refer to the User’s Manual  (FEH380).

Connections

• The UG230 internal user memory addresses ($u) must be used for memory allocation for switch,
lamp or data display parts.
When the master station specifies a screen number, data is written to the internal memory address
($u) allocated for the screen. If the screen is switched internally, the new screen number is read
and is written to the internal memory address ($u) allocated for the screen.

5-6

6.

6. UG-Link

UG-Link
• “UG-Link” is the network where the computer reads from and writes to the internal memory of the
UG230, memory card, PLC memory or temperature control/PLC2 memory using a dedicated
protocol.
Dedicated commands
Read
RUN

disc

STOP

...
...
...
...

...
...
...
...

...
...
...
...

...
...
...
...

Write
RESET

PC

PLC

UG230

• Use MJ1 of the UG230 for connection with a general-purpose computer. Use MJ2 for
communications with the PLC.
When the option unit UG230A-DCL is installed, it is possible to use CN1 for communications with
the PLC, MJ2 for connection to the PLC using the temperature controller or PLC2Way, and MJ2 for
communications with a computer. Data of the PLC or temperature controller can be collected
through communications with the UG230. Data collection is available even between the products
of different manufacturers.
• Either signal level RS-232C or RS-485 can be selected.
With RS-232C, one UG230 unit can be connected; with RS-485, a maximum of 31 UG230 units
can be connected.


disc

RESET

RS-485

MJ1

MJ1

Local port
1

Local port
2

Local port
31

* CN1

MJ2

MJ2

RS-232C
RS-422
RS-485

MJ2

RUN
STOP

RUN
STOP

...
...
...
...

...
...
...
...

...
...
...
...

PLC

...
...
...
...

PLC

...
...
...
...

...
...
...
...

PLC

...
...
...
...

MJ1

RS-232C
RS-422
RS-485

...
...
...
...

Temperature controller,
inverter or PLC

* [UG230 + UG230A-DCL]

• For more information, refer to the User’s Manual  (FEH380).

7. PLC2Way

7.

5-7

PLC2Way
• The “PLC2Way” function is an original network function where one UG230 can be connected to
two PLCs. Even if the manufacturers of these PLCs are not the same, they can be connected to
one UG230.
RS-232C
RS-422/RS-485

PLC (Mitsubishi)
run

MJ2

UG230
MJ1

RS-232C
RS-422/RS-485 (2-wire connection)
FA C TO RY

5

ACE

PROGRAMMER

PLC (Yokogawa)

• With the PLC2Way function, it is possible to communicate with PLCs without special program in
the same way as 1 : 1 connection.
Two PLCs that are connected to the UG230 are controlled at the same time, and memory
read/write operations are available with these two PLCs.
• Connection at MJ1 (PLC2Way) can be performed via RS-232C or RS-485 (2-wire).
With RS-232C, one PLC can be connected; with RS-485, a maximum of 31 PLCs can be
connected.
RS-232C
RS-422/RS-485
run

MJ2

UG230
MJ1

PLC

FA C TO RY

FA C TO RY

ACE

FA C TO RY

ACE

PROGRAMMER

PLC1

RS-422/RS-485 (2-wire connection)

ACE

PROGRAMMER

PLC2

PROGRAMMER

PLCn (nn == 11 to
~ 31
31)

• Periodical reading/sampling of PLC data on the PLC2Way side
When read/write memory addresses are preset on the temperature control network/PLC2Way
table, background data reading is performed at regular intervals. It is also possible to save the
read data in the UG230 internal buffer, SRAM or CF card.
• Data transfer between PLCs
The PLC memory data can be transferred to another PLC in blocks using a macro command.
• For more information, refer to the User’s Manual  (FEH380).

Connections

• Connect the first PLC to MJ2 (or CN1 when the UG230A-DCL is provided), and the second PLC
(PLC2Way) to MJ1.

5-8

8.

8. Temperature Control Network

Temperature Control Network
• Using the temperature control network, the UG230 can be connected to the temperature controller
or inverter.
With RS-232C, one PLC can be connected; with RS-485, a maximum of 31 temperature
controllers can be connected.

PLC

UG230

100

PV

Temperature
controller

SP2

SP
AL1

2 3

SP2

SP
AL1

MAN

A/M

A/M

SET/ENT

SET/ENT

1

100

PV

3 4

90

2 3

100

PV

3 4

SP2

SP

90

AL1

MAN

2 3

3 4

90
MAN

A/M
SET/ENT

2

n
(Max = 31)

• Data of temperature controllers connected to the UG230 can be set or monitored.
• Periodical reading/sampling of temperature controller data
When read/write memory addresses are preset on the temperature control network/PLC2Way
table, background data reading is performed at regular intervals. It is also possible to save the
read data in the UG230 internal buffer, SRAM or CF card.
• Data transfer
It is also possible to transfer data in the PLC memory, UG230 internal memory or a memory card
to the temperature controller at one time using a macro command. Conversely, data in the
temperature controller can be transferred to the PLC memory, UG230 internal memory or a
memory card at one time.
• For more information, refer to the User’s Manual  (FEH365).

9. Ethernet

9.

5-9

Ethernet
CAUTION

To perform Ethernet communications on the UG230, the option unit UG230A-DCL must
be installed.

• Transferring data in memory
Data in memory can be transferred to the UG230 on the Ethernet or to the PLCs linked to the
UG230 as a host by using macro commands (EREAD/EWRITE).

Ethernet

5
SYSTEM
F1

F2

F3



F4

F5

F6

F7

Connections

POWER

RS-232C
RS-485



• Communications between the server and the UG230
- “HKEtn10.dll” (for UDP/IP protocol) is provided so that the user can create an original
application by using Visual C++ or Visual Basic, etc. to allow the server to access the memory
device, such as UG230 internal memory, memory card or the PLC memory linked with the
UG230 as a host........ (a)
- The macro command (SEND) enables the UG230 to access the server........ (b)
Server

Application

(a)

(b)

Ethernet

SYSTEM
F1

F2

F3

F4



F5

F6

F7

POWER

RS-232C
RS-485



PROGRAMMER

PROGRAMMER

5-10

9. Ethernet

- Screen data can be transferred from the UG00S-CW editor on the server to the UG230.

Server
UG00S-CW

Ethernet

SYSTEM
F1

F2

F3

PROGRAMMER
F4



F5

F6

F7

Ethernet-ready PLC

POWER

RS-232C
RS-485



PROGRAMMER

• Communications between the Ethernet-ready PLC and the UG230
- The UG230 can communicate with the PLC on the Ethernet.

Ethernet

SYSTEM

SYSTEM

F1

F1

F2

F2

F3

F3

FA C TO RY

ACE

PROGRAMMER
F4

F4

F5

F5

F6

F6

F7

POWER







F7

POWER



* Ethernet-ready PLC only

- The UG230 can communicate with multiple PLCs on the Ethernet.

Ethernet

SYSTEM
F1

F2

F3

F4

F5

F6

F7

POWER









* Ethernet-ready PLC only

• For more information, refer to the User’s Manual  (FEH380).

6

POD Operations

1.

Operational Procedures

2.

Main Menu Screen

1. Operational Procedures

1.

6-1

Operational Procedures

POD Operation
Follow the procedure below to operate the POD.
1. Installation and wiring
For details, refer to Chapter 3.
2. Connection with devices including a PLC and a temperature controller
For instructions and precautions on wiring between the POD and other devices, refer to the
separate User’s Manual  (FEH380).
3. POD power-on
• New POD

6

4. Screen data creation and transfer
• New POD
Refer to “Initial Screen” (page 6-2).
• Other than the above
Refer to Chapter 5, “Data Transference” in User’s Manual  (FEH375).
5. Operation start
The POD becomes operable with a PLC or a computer connected to it.
* If the POD does not operate normally and shows an error message, eliminate the cause by
referring to Chapter 7.

POD Operations

• Other than the above
When the check screen below and then the next user screen are displayed correctly, go to
step 5.

6-2

1. Operational Procedures

Initial Screen
When the power of POD is turned on for the first time, the Main Menu screen shown below on the left
is displayed.
Initial screen displayed when power is turned
on for the first time

Main Menu screen after transferring screen
data

Transferring Screen Data for the First Time
There are some methods for transferring screen data for the first time.
• UG230 only
1. Transferring screen data via the UG00C-T or USB cable
Transfer screen data from the computer while the initial screen is displayed.
2. Transfer screen data from a CF card (USB CF card reader/writer) or a memory card
(UG00P-MR).
1) Transfer screen data from the computer to the desired card.
2) Connect a USB CF card reader/writer or a UG00P-MR to the UG230, and insert the card.
3) Press the [CF Card (English)] switch. The “Card Menu” screen
is displayed.
4) Follow the instructions as described in “Card Menu Screen”
(page 6-15) and transfer screen data.

1. Operational Procedures

6-3

• UG230 + UG230A-DCL (option unit)
1. Transferring screen data via the UG00C-T or USB cable
Transfer screen data from the computer while the initial screen is displayed.
2. Transfer screen data from a CF card.
1) Transfer screen data from the computer to a CF card.
2) Insert the CF card into the option unit.
3) Press the [CF Card (English)] switch. The “Card Menu” screen
is displayed.
4) Follow the instructions as described in “Card Menu Screen”
(page 6-15) and transfer screen data.
3. Transferring screen data via Ethernet
1) Press the [IP Address (English)] switch.
2) The “Ethernet” screen is displayed.
Follow the instructions as described in “Ethernet (Optional)”
(page 6-29) and set the IP address.
Press the [Setting Finished] switch. The initial screen is displayed again.

6

3) Transfer screen data from the computer via Ethernet.

1) Transfer screen data from the computer to a CF card.
2) Turn the UG230 off. Set the DIPSW1 on the UG230 to the ON position, and insert the CF
card into the USB CF card reader/writer or the option unit.
3) Turn the UG230 on. The screen data is automatically uploaded from the CF card to the
UG230.

POD Operations

• Auto-uploading screen data from the CF card to the UG230

6-4

2.

2. Main Menu Screen

Main Menu Screen
The Main Menu screen is displayed when the POD is in the STOP mode. In this state, the POD is
disconnected from the PLC and other external devices.

Displaying the Main Menu Screen
In the RUN Mode
To bring up the Main Menu screen in the RUN mode, press the [SYSTEM] switch and then the [F1]
switch while the vertical menu is displayed.
Main Menu screen

When the [SYSTEM] switch is disabled:
Pressing the [SYSTEM] switch does not bring up the vertical menu.
In this case, press the [SYSTEM] and [F5] switches at the same time. (If the time for simultaneous
pressing of these switches is preset, hold down the switches for the required time.)
Main Menu screen

When the [MODE] (F1) switch is disabled:
When the vertical menu is displayed by the [SYSTEM] switch, the [MODE] (F1) switch does not work.
In this case, press the [MODE] (F1) and [F5] switches at the same time. (If the time for simultaneous
pressing of these switches is preset, hold down the switches for the required time.)

Moving Back to the Screen in the RUN Mode
Press the [SYSTEM] switch and the [F1] switch.

2. Main Menu Screen

6-5

Main Menu Screen
• The Main Menu screen indicates the UG230 model, system information, and screen data
information.
• The Main Menu screen is the system menu screen for transferring screen data between a
personal computer and the UG230.
When transferring screen data from a personal computer to the UG230, this Main Menu screen
must be displayed. (However, if [Editor Port] is selected for [Modular Jack 1] or on-line editing is
used, it is not necessary to bring up this screen.)
UG230 model

I/O Test (See page 6-5.)

System program version
Font data versions,
country/local/font

Card Menu (See page 6-15.)
Communication parameter
(See page 6-27.)

PLC I/F driver version
and model

Extension (See page 6-28.)
Ethernet (See page 6-29.)

6

SRAM/Clock (See page 6-36.)

PLC model and file comment set
for the screen data file

1.

I/O Test
When the [I/O Test] switch on the Main Menu screen is pressed, the following “I/O Test” screen
appears. This screen is used to check that there is no problem with the UG230 interfaces and touch
switch operation.
Performs a USB-A (master port)
connection test. (See page 6-6.)

Moves to the “Touch Switch” screen.
(See page 6-13.)

Performs a CN1/MJ1/MJ2 interface test.
(See page 6-7.)

The Main Menu screen is displayed again.
(See page 6-5.)

Performs a function switch test.
(See page 6-13.)

POD Operations

Port name used
for data transfer

6-6

1-1.

2. Main Menu Screen

USB Test
When the [USB Test] switch is pressed, the following screen is displayed.
Moves back to the “I/O Test” screen.
(See page 6-5.)

This screen is used to check the status of USB-A (master port) connection.

Checking the Connection Status
If the lamp on the screen shows [No Connected] in blue, the device has not been connected to the
USB port correctly.
When the lamp shows [Connected] in red, the device is connected to the USB port correctly.

2. Main Menu Screen

6-7

Printer Test
When a printer is connected to the USB-A port, a print test can be done.
Check if the UG230 sends signals normally to the printer using the [Print] switch. The test is
successful if a test page is printed without problems.
Example:

!"#$%&@
!"#$%&@
!"#$%&@
!"#$%&@
!"#$%&@
!"#$%&@
!"#$%&@

1-2.

0123456789
0123456789
0123456789
0123456789
0123456789
0123456789
0123456789

ABCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
ABCDEFGHIJKLMNO

Serial Connection Test
When the [Serial Test] switch is pressed, the following screen is displayed.
Moves back to the “I/O Test” screen.
(See page 6-5.)

6
POD Operations

This is a signal test for communications through the MJ1, MJ2 or CN1 connector.
Perform this test if the communication is not successful when transferring screen data through MJ1,
connecting the PLC using MJ2 or CN1, or selecting multi-link 2, temperature controller/PLC2Way or
PLC for MJ1, or connecting the card recorder or serial extension I/O.

6-8

2. Main Menu Screen

MJ2 Test
RS-232C signal test
1. Slide the slide switch on the POD to the upper position for RS-232C.
2. Turn on the [MJ2] and [RS232C] switches under [Communication Port].
Communication Port
CN1

RS232C

MJ1

RS485

MJ2

3. Check the signals [RD] and [SD]. Wire inside MJ2 as shown below.
MJ2
Signal
Name

Pin No.

RD

7

SD

8

4. Press the [Self-Loop Test] switch. When the [OK] lamp lights up, the test is successfully
completed.

CTS

RTS

CTS

RTS

NG

OK

NG

OK

Self-Loop
Test

* If the [NG] lamp lights up, consult your local distributor.

Self-Loop
Test

2. Main Menu Screen

6-9

RS-422 signal test
1. Slide the slide switch on the POD to the lower position for RS-422.
2. Turn on the [MJ2] and [RS485] switches under [Communication Port].
Communication Port
CN1

RS232C

MJ1

RS485

MJ2

3. Check the signals [+RD], [−RD], [+SD] and [−SD]. Wire inside MJ2 as shown below.
MJ2
Signal
Name

Pin No.

+SD

1

−SD

2

+RD

7

−RD

8

4. Press the [Self-Loop Test] switch. When the [OK] lamp lights up, the test is successfully
completed.

RTS

CTS

RTS

NG

OK

NG

OK
Self-Loop
Test

Self-Loop
Test

* If the [NG] lamp lights up, consult your local distributor.

MJ1 Test
RS-232C signal test
1. Turn on the [MJ1] and [RS232C] switches under [Communication Port].
Communication Port
CN1

RS232C

MJ1

RS485

MJ2

2. Check the signals [RD] and [SD]. Wire inside MJ1 as shown below.
MJ1
Signal
Name

Pin No.

RD

7

SD

8

POD Operations

CTS

6

6-10

2. Main Menu Screen

3. Press the [Self-Loop Test] switch. When the [OK] lamp lights up, the test is successfully
completed.

CTS

RTS

CTS

RTS

NG

OK

NG

OK
Self-Loop
Test

Self-Loop
Test

* If the [NG] lamp lights up, consult your local distributor.

RS-485 signal test
MJ1 must be connected to MJ2 for an RS-485 signal test through MJ1. Therefore, perform a serial
connection test to check that there is no problem with MJ2 before conducting an MJ1 test.
1. Slide the slide switch on the POD to the lower position for RS-422.
2. Turn on the [MJ1] and [RS485] switches under [Communication Port].
Communication Port
CN1

RS232C

MJ1

RS485

MJ2

3. Check the signals [+RD], [-RD], [+SD] and [-SD]. Connect MJ1 and MJ2 as illustrated below.
MJ1
Signal
Name

MJ2
Pin No.

Signal
Name

Pin No.

+RD/+SD

1

+SD

1

−RD/−SD

2

−SD

2

+RD

7

−RD

8

4. Press the [Self-Loop Test] switch. When the [OK] lamp lights up, the test is successfully
completed.

CTS

RTS

CTS

RTS

NG

OK

NG

OK

Self-Loop
Test

* If the [NG] lamp lights up, consult your local distributor.

Self-Loop
Test

2. Main Menu Screen

6-11

CN1 Test (with the option unit)
RS-232C signal test
Turn the [CN1] and [RS232C] switches on.
Communication Port
CN1

RS232C

MJ1

RS485

MJ2

• SD/RD Test
Check the signals [SD] and [RD].
1. Install a jumper between pins 2 and 3 of CN1 on the backside of the UG230.
2. Press the [Self-Loop Test] switch. When the [OK] lamp lights up, the test is successfully
completed.

CTS

RTS

CTS

RTS

NG

OK

NG

OK
Self-Loop
Test

Self-Loop
Test

• CTS/RTS Test
Check the signals [CTS] and [RTS].
1. Install a jumper between pins 4 (RTS) and 5 (CTS) of CN1 on the backside of the UG230.
2. Press the [RTS] switch and check that both [RTS] and [CTS] lamps light up at the same time.
Press the [RTS] switch again and check that both [RTS] and [CTS] lamps go off at the same
time.

CTS

RTS

CTS

RTS

NG

OK

NG

OK

Self-Loop
Test

Self-Loop
Test

CTS

RTS

CTS

RTS

NG

OK

NG

OK

Self-Loop
Test

Self-Loop
Test

POD Operations

* If the [NG] lamp lights up, consult your local distributor.

6

6-12

2. Main Menu Screen

RS-485 signal test
Turn the [CN1] and [RS485] switches on.
Communication Port
CN1

RS232C

MJ1

RS485

MJ2

• SD/RD Test
Check the signals [SD] and [RD].
1. Install a jumper between pins 12 and 24 and between pins 13 and 25 of CN1 on the backside
of the UG230.
2. Press the [Self-Loop Test] switch. When the [OK] lamp lights up, the test is successfully
completed.

CTS

RTS

CTS

RTS

NG

OK

NG

OK
Self-Loop
Test

Self-Loop
Test

* If the [NG] lamp lights up, consult your local distributor.
• CTS/RTS Test
Check the signals [CTS] and [RTS].
1. Install a jumper between pins 14 (+RTS) and 19 (+CTS) of CN1 and between pins 17 (−RTS)
and 18 (−CTS) on the backside of the UG230.
2. Press the [RTS] switch and check that both [RTS] and [CTS] lamps light up at the same time.
Press the [RTS] switch again and check that both [RTS] and [CTS] lamps go off at the same
time.

CTS

RTS

CTS

RTS

NG

OK

NG

OK

Self-Loop
Test

Self-Loop
Test

CTS

RTS

CTS

RTS

NG

OK

NG

OK

Self-Loop
Test

Self-Loop
Test

2. Main Menu Screen

1-3.

6-13

SYSTEM & Function Switch Test
Check operations of six switches provided vertically on the right side of the panel.
Press the switch, and check that the lamp on the screen lights up while the switch is held down.

1-4.

Touch Switch Test
If a touch switch does not activate at all or if an operation is performed without pressing any touch
switch, check that the touch switches on the UG230 panel are working properly.

6

1. Press the [Switch Check] switch. Grids appear on the screen as shown below.

Y:

Return
Erase

2. Press a position on the panel, and check that the pressed position turns white.
The switch is activated normally when the pressed position turns white.
To move back to the “I/O Test” screen, press the [F4] switch.
To delete white dots press the [F5] switch.

X: 180

Y: 206

Return
Erase

3. If a position different from the pressed position turns white, refer to “Touch Switch Adjustment” on
the next page and adjust the touch switch position.

POD Operations

X:

6-14

2. Main Menu Screen

Touch Switch Adjustment
If a position different from the pressed position turns white on the touch switch test screen, follow the
steps described below to adjust the touch switch position.
1. Hold down the [SYSTEM] switch and press the [F2] switch on the touch switch test screen.

SYSTEM
3
X:

4

Touch Switch Adjustment

Y:

Fix

F2

X:

Reset

Y:

Return

Return

1

2

2. Press on “1” that is flashing at the corner on the
touch switch adjustment screen. When the finger
is released, a beep sounds and the position is set.
“2” flashes.

1

2

3. Press on “2” that is flashing at the corner. When
the finger is released, a beep sounds and the
position is set. “3” flashes.

1

2

Erase

4. Press on “3” that is flashing at the corner. When
the finger is released, a beep sounds and the
position is set. “4” flashes.
3

Touch Switch Adjustment

4
Fix

X:

Reset

Y:

5. Press on “4” that is flashing at the corner. When
the finger is released, a beep sounds and the
position is set.
3

Touch Switch Adjustment

4
Fix

X:

Reset

Y:

6. To re-set the positions, press the [F2] switch and
follow step 2 and later.
7. Press the [F1] switch. A long beep sounds and
the positions are determined. The touch switch
test screen is displayed again.

3

Touch Switch Adjustment
X:

8. To cancel the setting, press the [F3] switch. The
touch switch test screen is displayed again.
1

Y:

4
Fix

F1

Reset

F2

Return

F3

2

2. Main Menu Screen

2.

6-15

Card Menu Screen
When the [Card Menu] switch on the Main Menu screen is pressed, the following “Card Menu” screen
appears.
This screen is used to transfer screen data between the UG230 and a CF card or a memory card.
The Main Menu screen is displayed again.

1.

4.

5.
2.
3.

2. [Screen Data] switch
Press this switch when transferring screen data between the UG230 and a CF card.
3. [SRAM] switch
Press this switch when saving backup copies of the SRAM memory or when uploading the backup
data from the CF card to the UG230.
4. [Built-in Socket] switch
The CF card insertion position can be selected. If using a CF card while the option unit is
mounted, press this switch.
5. [USB Port] switch
The CF card insertion position can be selected. If using a CF card while a CF card reader/writer
(commercially available) is connected to the USB-A (master port), press this switch.

POD Operations

1. [Card Recorder Menu] switch
Press this switch when connecting the card recorder to the MJ port of the UG230 and transferring
screen data between the UG230 and a memory card.

6

6-16

2-1.

2. Main Menu Screen

Card Recorder Menu Screen
When the [Card Recorder Menu] switch on the “Card Menu” screen is pressed, the following “Card
Recorder Menu” screen appears.
This screen is used to transfer screen data between the UG230 and a memory card.
The procedure for transferring data is described below.

1. Connecting the UG00P-MR
Connect the UG00P-MR using the attached cable to the MJ port that is displayed in the “Port
Selection” field.
• MJ1: Connect the UG00P-MR to the MJ1 port. Normally MJ1 is
selected.
• MJ2: Connect the UG00P-MR to the MJ2 port. Only when
[Memory Card] is selected for [Modular Jack 2], “MJ2” is
indicated in the “Port Selection” field.
2. Mounting the Memory Card
Insert a memory card in to the card recorder.
3. Memory Card Information
Press the [Modular Jack MJ1] switch.
The memory card information contained in the inserted memory card is indicated.

To move back to the previous screen, press the [Close] button.

2. Main Menu Screen

6-17

4. Data Selection and Transfer Selection
In the “Transfer” field, select [Display <-- Card], [Display --> Card] or [Display <--> Card]. Press
the desired switch to turn the switch on. Multiple switches can be pressed in the “Data Selection”
field.
Data selection

Transfer selection

5. Starting Data Transfer
Press the [Start] switch. Data transfer is started. During data transfer, the [Start] switch changes
into [Busy] and flashes. When data is transferred, the following message is displayed.

6
POD Operations

Press the [OK] switch.
6. Press the [Return] switch. The “Card Menu” screen is displayed again.

6-18

2-2.

2. Main Menu Screen

Transferring Screen Data from a CF Card

CF Card Folder Configuration
Folders in the CF card are configured as shown below.
*1

*2

Folder Name
CF card

Folder Name

AAAAAAAA
BBBBBBBB

File Name

DSP

DSP0000.BIN

CARD

MCMHEAD.BIN
MCMxxxx.BIN

SRAM

SRM0000.BIN

MEMO

MEMxxxx.BIN

FFFFFFFF

RECIPE
SAMPLE
HDCOPY

RECxxxx.CSV
xxxxxxxx.CSV
SMPxxxx.BIN
SMPxxxx.CSV
HDxxxx.JPG
HDxxxx.BIN

BITMAP

BMPxxxx.BIN

JPEG

xxxx.JPG
JPxxxx.JPG

SNAP

VDxxxx.JPG

WAV

WAxxxx.WAV

FONT

xxxx.FTD
xxxxxxxx.SHT
xxxxxxxx.HTM
xxxxxxxx.TXT

WEBSERV
*3

DSPDEF

DSP

DSPDEF.BIN

Same as access folders

*1
*2
*3

These are access folders set by the UG00S-CW editor. Any folder name within eight 1-byte characters can be
given.
These folders are automatically created when access folders are created. The folder names are fixed.
The folder name for screen data auto uploading cannot be changed.

DAT0000 (access folder)
Folder Name

Contents

Folder Name

Contents

BITMAP

Saves pattern data (bitmap data) to reduce the
screen data capacity.

RECIPE

Reads and writes recipe data.

CARD

Writes recipe data from the UG30 using the
UG20-compatible memory manager function.

SAMPLE

Saves history data of the data logging
function.

DSP

Reads and writes screen data.

SNAP

Saves video snap images.

FONT

Saves Gothic fonts or language data to reduce
the screen data capacity.

SRAM

Saves backup data of SRAM.

HDCOPY

Writes hard copy images in the JPEG file format
from the UG30 (UG330H-SS only: BIN file).

WAV

Saves WAV files for sound output to reduce
the screen data capacity.

JPEG

Saves JPEG files for display on the screen
(except for UG330H-SS).

WEBSERV

Saves files to be accessed from the Web
browser.

MEMO

Saves memo pad data drawn with the UG30.

DSPDEF (screen data auto upload folder)
Folder Name
DSP

Contents
When setting the dipswitch on the POD and inserting a CF card, it automatically reads the screen data in this
folder.

(Other folders are the same as access folders.)

2. Main Menu Screen

6-19

Transferring Screen Data from a CF Card
The procedure of transferring data between the UG230 and a CF card is described below.
1. Mounting the CF Card
Insert the CF card into the CF card connector at the side of the UG230.
* Do not remove or insert the CF card in the later steps.
2. Data selection
Select [Screen Data]. When the lamp is red, it is selected.
3. Transfer selection
Select [Display <-- Card], [Display --> Card] or [Display <--> Card].
Data selection

Transfer selection

6
POD Operations

When [Display <-- Card] is Selected:
Transfer screen data from the computer to the CF card.
1. When [Display <-- Card] is selected, the following screen is displayed.
Flashes during communication with the CF card.

Indicates the name of the
currently selected folder.
The access folder that is set
for screen data defaults.
If there is no screen data,
“DAT0000” defaults.
Indicates the free space
in the CF card.
Used for checking or
renaming folder names.
Starts transferring data
[Display <-- Card].

Moves back to the previous
screen.
Indicates the information of the currently selected folder.

6-20

2. Main Menu Screen

2. Check the folder name, free space, and CF card file information. If the correct folder is selected,
move to step 4.
• Folder Name
Indicates the name of the currently selected folder.
The access folder that is set for screen data defaults.
If there is no screen data, “DAT0000” defaults.
• Rest Size
Indicates the free space in the CF card.
• CF Card File Information
Indicates the information of the currently selected folder.
3. To change to another folder, press the [Select Folder] switch.
The “Select Folder” screen is displayed.

Moves the cursor.

Indicates the details
of the folder.
Determines the folder
selection.

• To see the details of the folder, press the [Folder Detail] switch.
The “Folder Detail” screen is displayed.

Scrolls with the
[↑]/[↓] switch.

Moves the cursor.

Moves back to the “Select
Folder” screen.

• Select the desired folder using the [↑]/[↓] switch, and press the [OK] switch.
The Card Transfer screen is displayed again and the CF card file information of the selected
file is indicated.

2. Main Menu Screen

6-21

4. Press the [Select Data] switch.
The [Data Selection] window is displayed and the [Select Data] switch changes to [Start].

Select the desired data, and press the [Start] switch.

6

Press the [OK] switch.
The “Card Menu” screen is displayed.
If any other message is displayed, refer to page 6-26.

POD Operations

To cancel the [Data Selection] window, press the [Return] switch.
5. During data transfer, the [Start] switch changes into [Busy] and flashes. When data has been
transferred successfully, the following window is displayed. However, when [Sys. Program] or
[Select All] is selected, the Main Menu screen is displayed without this message window on
completion of data transfer.

6-22

2. Main Menu Screen

When [Display --> Card] is Selected:
1. When [Display --> Card] is selected, the “Card Transfer” screen is displayed.
Flashes during communication with the CF card.

Indicates the name of the
currently selected folder.

Indicates the free space
in the CF card.

Starts transferring data
[Display --> Card].

Moves back to the previous
screen.
Indicates the information of the currently selected folder.
If there is no screen data, this field becomes blank.

2. Check the folder name and CF card file information, and press the [Start] switch.
* When the access folder name of screen data is the same as that in the CF card, the CF card
file information is indicated on the screen, and data in the unit overwrites the CF card data.
Note that the CF card data is lost when data in the unit overwrites.
When the CF card file information is blank, a new file “DSP0000.BIN” is created in the DSP
folder.
3. During data transfer, the [Start] switch changes into [Busy] and flashes. When data has been
transferred successfully, the following window is displayed.

Press the [OK] switch. The CF card file information shows data that has been transferred.
If any other message is displayed, refer to page 6-26.
4. Press the [Return] switch. The “Card Menu” screen is displayed again.

2. Main Menu Screen

6-23

When [Display <--> Card] is Selected:
1. When [Display <--> Card] is selected, the “Card Transfer” screen is displayed.
Screen data used for comparison is that in the DSP folder under the folder having the same name
as the access folder that is set by the UG00S-CW editor.
Flashes during communication with the CF card.

Indicates the name of the
currently selected folder.

Indicates the free space
in the CF card.

Starts transferring data
[Display --> Card].

6

Moves back to the previous
screen.

2. Press the [Start] switch.
3. During data transfer, the [Start] switch changes into [Busy] and flashes. When data has been
transferred successfully, the following window is displayed.

Press the [OK] switch.
If any other message is displayed, refer to page 6-26.
4. Press the [Return] switch. The “Card Menu” screen is displayed again.

POD Operations

Indicates the information of the currently selected folder.
If there is no screen data, this field becomes blank.

6-24

2-3.

2. Main Menu Screen

Saving Backup Copies of SRAM
In this section, the procedure for saving backup copies of the SRAM memory for battery replacement
is explained.
1. Press the [SRAM] switch on the “Card Menu” screen. When the lamp is red, it is selected.
2. Select [Display <-- Card], [Display --> Card] or [Display <--> Card].
Data selection

Transfer selection

3. The “SRAM Transfer” screen is displayed.
• When [Display --> Card] or [Display <--> Card] is selected, the following screen is displayed.
Select the CF card folder having the same name as the access folder for screen data in the
unit. The name is shown on the screen. The transferred file is named as “SRM0000.BIN”.
Shows [Display <--> Card] when [Display <--> Card] is selected.

Indicates the name of the
currently selected folder.

Indicates the free space
in the CF card.
Used for checking or
renaming folder names.
Starts transferring data
[Display --> Card].

Moves back to the
previous screen.
Flashes during communication with the CF card.
Indicates the name of the currently selected file.

2. Main Menu Screen

6-25

• When [Display <-- Card] is selected, the following screen is displayed.

Indicates the name of the
currently selected folder.

Indicates the free space
in the CF card.
Used for checking or
renaming folder names.
Starts transferring data
[Display <-- Card].

Moves back to the
previous screen.
Flashes during communication with the CF card.
Indicates the name of the currently selected file.

2) The “Select Folder” screen is displayed as shown on page 6-20.
Select the desired folder (refer to page 6-20), and press the [OK] switch.
3) Moves back to the “SRAM Transfer” screen.
4. Starting Data Transfer
Check the folder name, free space and transfer selection, press the [Start] switch.
Data transfer is started.
5. Ending Data Transfer
When data has been transferred successfully, the following window is displayed.

Press the [OK] switch.
If any other message is displayed, refer to the next page.
6. Pressing the [Return] switch moves back to the “Card Menu” screen.

POD Operations

1) To change to another folder, press the [Select Folder] switch.
(The folder name must be “SRM0000.BIN”.)

6

6-26

2-4.

2. Main Menu Screen

Messages during Data Transfer
If an error occurs during data transfer, the message
window shown on the right is displayed.

The kinds and the contents of the messages are shown below. The same messages are used for the
memory card and CF card. When using the CF card, the “memory card” in the explanation should
read as the “CF card”.
Message
Work normally finished.

Contents
The specified operation has been concluded normally.

Card recorder not connecting

No card recorder is connected when selecting a modular jack.

UG00P-MR Communication Error

A communication error occurred between POD and UG00P-MR when
selecting a modular jack.

Card not setting

Memory-Card not setting

Memory-Card Capacity over

Cannot write the data into a memory card because the data size in POD is
larger than the capacity of a memory card.

Write Protect: ON

Cannot write data into a memory card because the write protect switch in a
memory card is ON.

Writing Error occurred.

The error occurred while writing data into a memory card.

Selected data does not exist.

The data in the reading target does not exist.

UG type is different.

The specified type of the data in POD is different from the type of the memory
card data.

Selected data can not be read.

The data in a memory card cannot be read.

Reading Error occurred.

The error occurred during writing data into a flash ROM of POD.

Data discrepant

There is some discrepancy in data, when comparing data between a memory
card and POD.

Screen data on UG will be broken.

Warning about data destruction in POD that may occur when transferring the
font data larger than the present data from a memory card to POD.
(The [OK] switch continues transferring; the [Cancel] switch stops
transferring.)

Undefined Error occurred.

The error occurred due to some cause other than mentioned above.

2. Main Menu Screen

3.

6-27

Communication Parameter Screen
When the [Comm. Para.] switch on the Main Menu screen is pressed, the “Comm. Param.” screen,
shown below, is displayed.
This screen is used to check the UG230 communication parameter settings.
The Main Menu screen is displayed again.

Communication parameter setting

6
POD Operations

Multi-link 2 or multi-link settings
Displayed when [Multi Link] or [Multi Link 2] is selected
for [Connection] on the [Comm. Parameter] dialog

6-28

4.

2. Main Menu Screen

Extension Program Information
When the [Extension] switch on the Main Menu screen is pressed, the following “Extension Prog. Info.”
screen appears.
The driver setting and parameter setting for temperature controller/PLC2Way communication, ladder
transfer function, Modbus slave communication, etc. are displayed.

2. Main Menu Screen

5.

6-29

Ethernet (Optional)

CAUTION

When performing Ethernet communication on the UG230, the option unit UG230A-DCL
must be installed.

The “Ethernet Information” screen is displayed by pressing the [IP Address (English)] switch on the
initial screen when transferring screen data via Ethernet for the first time, or by pressing the [Ethernet
Information] switch on the Main Menu screen when transferring screen data to a UG230 equipped with
the option unit UG230A-DCL.

5-1.

Ethernet Information Screen
This screen is used to check the current IP address, port number, or error.
Moves to the “Ethernet” screen for IP Address
Setting. (See “IP Address Setting” (page 6-30))

The Main Menu screen is displayed again.

6
POD Operations

Pressing the [Ethernet] switch brings up the “Ethernet” screen for IP address setting.

To move back to the previous “Ethernet Information” screen, press the [Ethernet Information] switch.

6-30

5-2.

2. Main Menu Screen

IP Address Setting
IP address (number for identifying UG230 on the network) setting is required before conducting
communications via Ethernet. The setting procedure varies depending on the screen data conditions.
[ IP Setting] is
checked in the [Unit
Setting] window on
the editor.

No

Network table is set
on the editor.

Yes

Network table is set on
the editor.

No *

No *

“Setting 1”
(page 6-31)

Yes

“Setting 2”
(page 6-32)

“Setting 3”
(page 6-33)

Yes

No *

Network table on the
editor contains a local
port setting.

CAUTION

Yes

“Setting 4”
(page 6-34)

* When no network table is set on the editor:
• Ethernet macro commands (EREAD, EWRITE, and SEND) disabled
• Communication with PLC via Ethernet disabled
For more information, refer to page 6-32.

2. Main Menu Screen

6-31

Setting 1
The Ethernet screen is displayed.

Used for checking the
10BASE-T interface.
Normal: Connect
Error:
Disconnect
Cursor switches

Increment/Decrement switch for
the value in the cursor position

6
Determines the setting such as IP address,
and moves back to the Main Menu screen.

1. Open the “Ethernet” screen from the “Ethernet Information” screen using the [Ethernet] switch.
2. Set the IP address and other necessary options.
3. Press the [Setting Finished] switch to move back to the Main Menu screen.

POD Operations

Set the IP address on the POD screen.

6-32

2. Main Menu Screen

Setting 2
The Ethernet screen is displayed.

Used for checking the
10BASE-T interface.
Normal: Connect
Error:
Disconnect
Cursor switches

Increment/Decrement switch for
the value in the cursor position

Determines the setting such as IP address,
and moves back to the Main Menu screen.

By pressing the [IP Address Setting] switch,
the desired IP address can be selected from
the network table.
The switch changes into [Select IP Address
from Network Table.].*1

*1

Network Table
Register IP addresses and other information for the UG230, PLCs or computers that should be included for
Ethernet communications on the UG00S-CW editor.
([System Setting] → [Network Table Setting] → [Ethernet] → Edit Network Table)
If you would like to use the IP address of the registered network table, select [IP Address from Network Table].

Network table
number

2. Main Menu Screen

6-33

Set the IP address on the Main Menu screen.
1. Press the [Ethernet] switch on the Main Menu screen to bring up the Ethernet screen.
2. Change the switch on the screen into [Select IP Address from Network Table.].
3. Select the desired IP address by changing the network table number.
4. Press the [Setting Finished] switch to move back to the Ethernet screen.

Setting 3
Set the IP address on the editor.
1. On the editor, chick [System Setting], [Unit Setting] and [IP Address Setting]. The [IP Address
Setting] dialog is displayed.
2. Check [

IP Setting].

6
POD Operations

3. Set the following options.
• IP Address
• Default Gateway
• Sub Net Mask
• Port No.
• Send Timeout
• Memory Protect
4. Click the [OK] button and transfer the screen data. The IP address set above can be checked on
the “Ethernet Information” screen to be displayed from the Main Menu screen.

6-34

2. Main Menu Screen

Setting 4
Set the IP address on the editor.
1. On the editor, chick [System Setting], [Unit Setting] and [IP Address Setting]. The [IP Address
Setting] dialog is displayed.
2. Check [

IP Setting].

3. Check [ Select IP Address from Network Table]. Enter the network table number with which
POD’s IP address is registered.

4. Click the [OK] button and transfer the screen data. The IP address set above can be checked on
the “Ethernet Information” screen to be displayed from the Main Menu screen.

2. Main Menu Screen

6-35

Changing the IP Address Temporarily
The IP address can be changed temporarily on the POD screen.
The screen to be used varies depending on the method of IP address setting (page 6-30).

Setting 1/2
Select [IP Address Setting].

Cursor switches

Increment/Decrement switch for
the value in the cursor position

6
POD Operations

Setting 3/4

Cursor switches

Increment/Decrement switch for
the value in the cursor position

6-36

6.

2. Main Menu Screen

SRAM/Clock
• To use the built-in clock of the UG230, it is necessary to select [SRAM/Clock Setting] from the
[System Setting] menu and make the SRAM/clock setting.
For the setting procedure, refer to the User’s Manual  (FEH376).
• Be sure to set the battery when using the built-in clock of the UG230. Without battery, the contents
in the SRAM or clock data will not be retained.
When the battery is not connected, the message “Battery not set” is displayed and the
[SRAM/Clock] switch flashes on the Main Menu screen. Connect the battery immediately.
When the battery is to be replaced, the message “Brownout Battery” is displayed.

[SRAM/Clock] switch

Indicates the message,
such as “Battery not set”
or “Brownout Battery.”

• When the [SRAM/Clock] switch on the Main Menu screen is pressed, the following “SRAM/Clock
Adjustment” screen appears.
This screen is used for adjusting the built-in calendar and for initializing the SRAM area.

2. Main Menu Screen

6-37

Date and Time Setting
1. Move the cursor using the [←] / [→] switch, and change the value by pressing the [+] / [−] switch.
2. When the desired date and time are set, press the [Set] switch to determine the setting.
3. The calendar data is updated as set.

Initializing SRAM
When the SRAM memory or cassette is initialized, the data contained is cleared. Double-check before
initializing the SRAM memory or cassette.
1. Press the [Format] switch and the [Execute] switch.
2. The SRAM area is initialized in the current screen data format. When initialization has been
completed, the message “∗∗Format Completed∗∗” is displayed.

6
POD Operations

6-38

7.

2. Main Menu Screen

Extended Function Setting
When the [Editor: MJ1] switch on the Main Menu screen is pressed, the following “Extended Function
Setting” screen appears.
Set the baud rate to be used when transferring screen data between the UG230 and a modem.
1. Select the desired baud rate using the [↑] / [↓] switch, and press the [Setting Finished] switch.
(Setting range: 4800, 9600, 19200, 38400, 57600, 115200)
* The function switches and switches on the Main Menu screen are not valid for 15 seconds
after the [Setting Finished] switch is pressed.
* When the [Setting Finished] switch is pressed, an AT command is automatically sent to the
modem and the baud rate used between the UG230 and the modem is set.
2. The Main Menu screen is displayed automatically. [Modem Connect Mode] automatically appears
under [Editor: MJ1].
3. To transfer screen data without a modem, select “Not used” for [Modem Comm. Baud Rate].
For screen data transfer while a computer is connected with UG00C-T, specify [Not Used] for
[Modem Comm. Baud Rate].

Pressing the [Editor: MJ1] switch
brings up the “Extended
Function Setting” screen.

Pressing the [Setting Finished] switch
moves back to the Main Menu screen.

7

Error Correction

1.

Error Messages

2.

Troubleshooting

7-1

1. Error Messages

1.

Error Messages
There are five kinds of error messages displayed on the UG30 series:
1. Communication error
2. Check
3. Warning
4. SYSTEM ERROR
5. Touch switch is active

1.

Communication Error

* When you go to [Comm. Parameter],
bring up the [Detail] tab window and set
[Continue] for [Comm. Error Handling],
a screen like the one shown below is
displayed.

7

Communication Error
Time-Out

MENU

Contents
Although a request to send is given to the PLC,
no answer is returned within the specified time.

Timeout

Parity

An error occurred in parity check.

Framing

Although the stop bit must be [1], it is detected
as [0].

Overrun

After one character is received, the next
character is received before internal processing
is completed.

Check code error

The check code in the PLC response was not
correct.

Solution

Remarks

1. Check the communication parameters.
2. Check the cables and wiring.

1

3. Data may be disrupted because of noise.
Fix noise.

2

1. Check the cables and wiring.

1

2. Data may be disrupted because of noise.
Fix noise.

2

1. Check the communication parameters.
2. Check the cables and wiring.

1

3. Data may be disrupted because of noise.
Fix noise.

2

1. Check the communication parameters.

1

2. Data may be disrupted because of noise.
Fix noise.

2

1. Check the communication parameters.

1

2. Data may be disrupted because of noise.
Fix noise.

2

* If the above error messages are displayed on the POD without establishing communication
between POD and PLC, test the solution of remark “1.”
If the error occurs suddenly in communication, test the solution of remark “2.”

Error Correction

Error Message

7-2

1. Error Messages

Error Message

Contents

Solution

Error code received

The PLC sent an error code (NAK).

Examine the PLC error code and solve the
problem.

Break

The PLC’s SD (TXD) remains at the low level.

Examine the connection between the PLC’s SD
(TXD) and the UG series RD (RXD).

Invalid memory
(applicable to Mitsubishi
CPU)

You specified an address that exceeds the
memory range of the PLC that you are linked to.

Check the type and range of memory that you
set.

Invalid CPU model
(applicable to Mitsubishi
CPU)

The PLC currently being supported does not
have a corresponding CPU.

Confirm whether or not the CPU that you are
using can be used with the UG series.

Format

The code of the received data is invalid.

Check 1, 2, 3 described below.

Compare
(applicable to HIDIC S10)

Transmission data and received data are
different.

Check 1, 2, 3 described below.

NAK
(applicable to
Allen-Bradley PLC)

A NAK code is received.

Check 1, 2, 3 described below.

TNS discrepant
(applicable to
Allen-Bradley PLC)

Transmitted TNS data and received TNS data
are not in agreement.

Check 1, 2, 3 described below.

Communication Error

An unclear communication error is detected.

Check 1, 2, 3 described below.

Count error
(applicable to Mitsubishi
CPU and Q link unit)

The expected data amount is different from the
count value.

Check 1, 2, 3 described below.

Command error
(applicable to Mitsubishi
CPU and Q link unit)

The response code differs from the expected
code.

Check 1, 2, 3 described below.

Invalid cassette
(applicable to Mitsubishi
ACPU)

This cassette is not included in the memory
cassettes currently being supported.

Contact your local distributor.

Password error
(applicable to Mitsubishi
QCPU)

The password is incorrect.

Contact your local distributor.

Solution
1. Confirm link unit settings. (After making settings, cut power to the PLC.)
2. Go to the editor and confirm the settings in the [Comm. Parameter] dialog in the [System Setting]
menu.
3. If errors only occur from time to time, it is possible that there is a noise-based communication error.
* If you still cannot solve the error even after following the suggestions above, contact your local
distributor.

Error Messages for Network Communication
• Ethernet
Error Message
Ethernet Error: XXXX

Contents
The Ethernet status is saved at system memory
address $s518 and a code other than “0”
(normal) is received.
XXXX: Error No.

Solution
For the contents and solution to each error
number, refer to Appendix 5 of the User's
Manual  (FEH376) separately
provided.

1. Error Messages

2.

7-3

Check
Error Message

Contents

Screen No. Error

Data has some error.
Error : XX (XX : XXX)

Solution

There is no setting for the received screen.

At the start of communications, the UG30 series
regards the value in the read area “n + 2” as the
screen number.
Check that the value in the read area “n + 2” is
an existing screen number on the PLC.

There is an error in the created screen data.

“Error : XX (XX : XXX)” indicates the edited
screen and the contents of the error.
For the error details and solutions, refer to the
User's Manual  (FEH376) and
correct screen data.

Communication Error
Check I/F driver

7
Contents
Although a request to send is given to the
computer, no answer is returned within the
specified time.

Communication Error
Check I/F driver

3.

Solution
The I/F driver for simulator is transferred.
If you do not use the simulator, uncheck [Use
Simulator] before transferring data.

Warning
An error may be displayed on the Main Menu screen during data transfer.
This is a warning message.
For the warning details and solutions, refer to the User's Manual  (FEH376) and correct
screen data.

Warning message

Error Correction

Error Message

7-4

4.

1. Error Messages

SYSTEM ERROR
When a system error is detected, the following error screen is displayed.

SYSTEM ERROR : 32
TEA : XXXXXXXX EXPEVT : XXXXXXXX
SSR : XXXXXXXX
SPC : XXXXXXXX
R0 : XXXXXXXX
R1 : XXXXXXXX
R2 : XXXXXXXX
R3 : XXXXXXXX
R4 : XXXXXXXX
R5 : XXXXXXXX
R6 : XXXXXXXX
R7 : XXXXXXXX
R8 : XXXXXXXX
R9 : XXXXXXXX
R10 : XXXXXXXX
R11 : XXXXXXXX
R12 : XXXXXXXX
R13 : XXXXXXXX
R14 : XXXXXXXX
R15 : XXXXXXXX

ERROR: XX
1:
11:
30:
31:
32:
33:
34:
35:

Watch dog timer error
Switch table error
Request for displaying full error
Memory allocation system error
General exceptions/MMU address system error
RTOS system error
Memory error
Inaccurate memory error

The source of the error could be one of the following three problems.
1) Program crash due to noise
2) Hardware problem
3) Bad program
Solve relevant problems by following the directions in “Troubleshooting” (page 7-5).
If the problem persists, contact your local distributor.

5.

Touch Switch is Active
If the power is turned off while a touch switch is
activated, the following error screen is displayed.
Remove your finger from the screen.
If the error screen remains displayed, contact your
local distributor.

Touch switch is active.
Keep hand off the screen.

2. Troubleshooting

2.

7-5

Troubleshooting

In the Event of an Error
Perform the steps below:
1. If the current error matches a symptom in the following table, correct it by following the instructions
provided.
2. If the error does not match the symptoms in the table, contact your local distributor.
Please provide the distributor with the information on the POD model, serial number, symptom of
the error, error message (if shown), etc.

Probable Symptoms
Symptom
POD is connected to the
PLC; however,
communication fails.
“Communication Error:
Time-Out” appears on the
screen.

Communications have been
successful. However,
“Communication Error:
Parity” or “Communication
Error: Framing” suddenly
occurs.

Solution
Solutions are:

1) Cables are not connected correctly or any
cable is disconnected.

1) Check the cable connection.

2) PLC parameter settings are not correct or
disagree with the POD settings.

2) Recheck the PLC parameter settings.

3) The POD is faulty.

3) Perform a self-loop test on the “I/O Test”
screen (page 6-7).
If the test is not successful, please return
the POD to your local distributor
immediately.

The error code denotes a PLC error (NAK).
1) When the error code appears only on a
certain screen, a memory address that
does not exist on the PLC may be set on
the POD screen.

1) Check if any address outside the allowable
range for PLC memory is set on the screen.

2) When the error code appears at power-on,
a memory address that does not exist on
the PLC may be set for communication
parameters, buffering area, initial macro,
etc.

2) Check if any address outside the allowable
range for PLC memory is set for
communication parameters, buffering area,
initial macro, etc.

Noise may cause the error.

Check if appropriate measures are taken
against noise.
Example:
Check if communication and power cables are
bundled together.
Try to attach a ferrite core to the
communication cable.
Try to attach a noise filter to the power supply,
etc.

7
Error Correction

Communications have been
successful. However,
opening a certain page
always causes a
“Communication Error: Error
code received” error.

Cause
Probable causes are:

7-6

2. Troubleshooting

Symptom
“SYSTEM ERROR: xx”
occurs.

SYSTEM ERROR : XX
TEA : XXXXXXXX EXPEVT : XXXXXXXX
SSR : XXXXXXXX
SPC : XXXXXXXX
R0 : XXXXXXXX
R1 : XXXXXXXX
R2 : XXXXXXXX
R3 : XXXXXXXX
R4 : XXXXXXXX
R5 : XXXXXXXX
R6 : XXXXXXXX
R7 : XXXXXXXX
R8 : XXXXXXXX
R9 : XXXXXXXX
R10 : XXXXXXXX
R11 : XXXXXXXX
R12 : XXXXXXXX
R13 : XXXXXXXX
R14 : XXXXXXXX
R15 : XXXXXXXX

Cause

Solution

The following causes are probable, depending
on the symptoms.
1) Turning the power off and back on corrects
the error.
↓
Communication failed because of improper
timing.

1) If communication is stable after turning the
power on again, continue and observe
operation.

2) Turning the power off and back on does not
correct the error.
↓
A certain condition always causes the error.
Or the POD is faulty.

2) Make a note of the information on error
number, etc. displayed on the screen and
contact your local distributor.

3) A CF card is inserted.
↓
The CF card (front and back) may be
reversed.

3) Check that the inserted CF card faces the
correct side.

If none of the above matches your error,
contact your local distributor.
Switches do not work.

The screen becomes dark or
black.

1) Switches do not work in the RUN mode. A
beep sounds.
↓
Is the switch interlock enabled?

1) Check the settings of switch functions, etc.
on the editor.

2) Switch activation position is wrong.
On the “I/O Test” screen displayed from the
Main Menu screen, press the [Switch
Check] switch. On the touch switch test
screen, a position different from the
pressed position is activated.
↓
The switch activation position may be
misaligned.

2) Perform a touch switch adjustment (page
6-14).

3) Switches do not work even in the STOP
mode.
On the “I/O Test” screen displayed from the
Main Menu screen, press the [Switch
Check] switch. When the touch switch test
screen is pressed, nowhere is activated.
↓
POD switches may be faulty.

3) Return the POD to your local distributor.

1) Touching the screen restores it to the
previous illuminated state.
↓
The backlight operates automatically as
preset.

1) The time for turning off the backlight can be
changed on the editor.

2) Touching the screen does not restore it.
However, the POWER lamp is lit.
↓
The backlight may be at the end of its life.
Or the POD may be faulty.

2) Return the POD to your local distributor.

2. Troubleshooting

Symptom
Screen data cannot be
transferred.

7-7

Cause

Solution

1) Screen data transfer has never succeeded.
↓
There may be some errors in the settings
on the computer.

1) In the [Transfer] dialog box on the editor,
decrease the baud rate by one level. Also
check that the correct COM port is
selected.

2) Screen data transfer was possible, but is
disabled now.
↓
The POD may be faulty. Or, there may be
some errors in settings.

2) Check if the modem connection mode is
selected (“Modem Connect Mode”
displayed at the bottom of the Main Menu
screen denotes the mode).
Also perform an RS-232C self-loop test
(page 6-7).

3) Only serial transfer is successful.
↓
There may be some errors in the Ethernet
or USB settings.

3) Transfer via Ethernet
Check that the IP addresses set on the
editor and the POD are the same.
Also check if any error due to Ethernet
connection occurs on the POD.
Transfer via USB
Is the USB driver recognized? Has the
driver been installed successfully (page
2-21)?
If the problem persists, contact your local
distributor.

7
Error Correction

7-8

2. Troubleshooting

Please use this page freely.

8

Inspection and
Maintenance

1.

Inspection and Maintenance

2.

Warranty Policy

1. Inspection and Maintenance

1.

8-1

Inspection and Maintenance

DANGER

Be sure to turn off the power before conducting inspection or maintenance. Failure to
do so could cause an electric shock or damage to the unit.

Daily Inspection
• Check that the screws on the POD are tightened firmly.
• Check that the connectors and terminal screws used for connection with other devices are
tightened firmly.
• If the display surface or frame is dirty, wipe it with a soft cloth soaked in alcohol (commercially
available).
• Conduct periodical inspection once or twice a year. The number of inspections may be increased
as necessary if facilities are relocated or modified, or the environment is hot, humid, or dusty.

Periodical Inspection
Inspect the following points periodically.
• Are the ambient temperature and humidity appropriate?
0 to +50°C, 85%RH or less
• Are the environmental conditions appropriate?

8

• Does the atmosphere contain no corrosive gas?

• Are the POD mounting screws tightened firmly?
• Are the connectors and terminal screws used for connection with other devices tightened firmly?
• Is the lithium primary battery within the expiry date?

Inspection and Maintenance

• Is the source voltage in the allowable range?
With AC power supply: 100 - 240 VAC
With DC power supply: 24 VDC ± 10%

8-2

2.

2. Warranty Policy

Warranty Policy

Inquiries about Failure
Please direct inquiries about failure or repair to your local distributor.
Your information on the POD model, serial number, symptom of the failure, error message (if shown),
etc. will be appreciated.

Warranty Period
The product is under warranty for one year after the date of purchase or delivery to the specified place.
On the assumption that the maximum stock period of the product after manufacture is 6 months, the
warranty period is limited to 18 months (checked by the serial number) after manufacture. When a
warranty period is specified in the contract, however, the period in the contract takes precedence.

Free-of-charge Repair
If the product fails before the expiry of the warranty, it will be repaired free of charge.
However, repair of any failure resulting from the causes below will be chargeable even within the
warranty period.
• Breakage of or damage to the appearance (case or surface sheet), touch switches, LCD, or other
components due to dropping, impact, or mishandling
• LCD or backlight at the end of life
• Fusion of a printed circuit board pattern associated with connection to external devices, or fusion
of a pattern in the terminal block or connector section of a printed circuit board caused by
short-circuiting of external load circuit
• Overvoltage or different voltage applied due to wiring mistake (power supply terminal, external
communication terminal, or other terminal blocks)
• Failure caused by lightning surge
• Failure due to the entry of conductive substances, water, solvent, particles, etc. under
inappropriate environmental conditions
• Failure due to inappropriate environmental conditions (e.g. corrosive gas or high humidity)
• Failure due to vibration or impact exceeding the specified level
• Disassembly and modification by the customer or failure obviously resulting from improper
handling by the customer

Chargeable Repair
Any failure that occurs after the expiry of the warranty or does not satisfy the requirements for the
free-of-charge repair will be repaired on an chargeable basis.

Gate City Ohsaki, East Tower,
11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan
Phone:
+81-3-5435-7135 ~ 8
Fax:
+81-3-5435-7456 ~ 9
URL:
http : // www.fujielectric.co.jp / fcs / eng
Information in this manual is subject to change without notice.

2004-2(PDF)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2004:02:09 15:02:21+09:00
Create Date                     : 2004:02:05 16:05:36Z
Subject                         : All Page
Page Count                      : 124
Page Mode                       : UseOutlines
Has XFA                         : No
Page Layout                     : SinglePage
Producer                        : Acrobat Distiller 4.05 for Windows
Author                          : Fuji Electric FA Co., Ltd.
Mod Date                        : 2004:02:09 15:02:21+09:00
Creation Date                   : 2004:02:05 16:05:36Z
Metadata Date                   : 2004:02:09 15:02:21+09:00
Creator                         : Fuji Electric FA Co., Ltd.
Title                           : FEH381_HARDWARE
Description                     : All Page
EXIF Metadata provided by EXIF.tools

Navigation menu