Fujitsu Client Computing IOT008 Remote Monitoring Station User Manual Short Term Confidential

Fujitsu Limited Remote Monitoring Station Short Term Confidential

(Short-Term Confidential) User Manual

Download: Fujitsu Client Computing IOT008 Remote Monitoring Station User Manual  Short Term Confidential
Mirror Download [FCC.gov]Fujitsu Client Computing IOT008 Remote Monitoring Station User Manual  Short Term Confidential
Document ID3187987
Application ID0LRsfYDLa4M+9+IhAEmIXA==
Document Description(Short-Term Confidential) User Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize80kB (999944 bits)
Date Submitted2016-11-07 00:00:00
Date Available2017-05-07 00:00:00
Creation Date2016-10-26 18:02:23
Producing SoftwareiTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version)
Document Lastmod2016-10-26 18:02:24
Document Title(Short-Term Confidential) User Manual
Document CreatorCubePDF

Remote Monitoring Station
Instruction Manual (detailed version)
How to Use This Manual
Pages 3 and 4 of this document contain the same information as the instruction manual “Usage Precautions”
sheet packaged with Remote Monitoring Station (“the product”). Pages in this section are not numbered.
If you require a printed copy of the instruction manual, please print pages 3 and 4 of this document on
B4 or larger sized paper.
Detailed information on the product’s functions is included from page 5 of this document. Please refer
to it when managing the system.
Content
■ Alarm Indication ................................................ 3
■ To users of this product ........................................ 3
■ Confirm included items prior to use ............................. 3
■ Ports and controls – main unit - ................................ 3
■
Power ON/OFF .................................................. 3
■ Installation of Remote Monitoring Station ....................... 3
■ Safety Notes .................................................... 4
■ Disposal ........................................................ 4
■ Additional Information .......................................... 4
■ Detailed information ........................................... 5
□ Function List ....................................................................................................... 5
□ Sound playback function.............................................................................................. 7
□ Limitations of each sensing......................................................................................... 10
□ Main unit operation (Gateway Software Configuration Tool) ........................................................... 11
□ Main unit operation (Device Management Tool) ........................................................................ 12
□ Setting method when function is not used............................................................................ 12
□ Product operation ( Button )........................................................................................ 13
□ LED list ........................................................................................................... 15
□ Connection of external devices...................................................................................... 15
Remote Monitoring Station
- Precautions for use To users of this product
Please contact the source this product was obtained from
if you have any questions about using this product or if
you need help resolving any concerns.
More Information can be found on the Internet at:
http://www.fmworld.net/biz/uware/support/
■ Alarm Indication
In this manual, various pictures are used to indicate alarm. These are signs to prevent
harms and damages that might be added to you and other people. The display and the
meaning are as follows.
DANGER
When this display is disregarded and wrong handling is done,
there is a high possibility that the person dies or sustains
severe injuries.
WARNING
When this display is disregarded and wrong handling is done,
there is a possibility that the person dies or sustains severe
injuries.
CAUTION
When this display is disregarded and wrong handling is done,
there is a possibility that the person owes injury or the
property damage occurs.
The following sign is used to show what one the content of harm and damage is.
The sign shown by △ means prompts warning and attention. A concrete
content of warning is shown in the sign and sideward of that.
The sign shown by means an act of not doing (prohibited activity).
A concrete content of the prohibition is shown in the sign and sideward
of that.
The sign shown by ● means what you must do. A concrete content of the
instruction is shown in the sign and sideward of that.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of
such marks by FUJITSU LIMITED is under license.
Google, Google logo, Google Play and Android is a trademark of Google Inc. or a registered trademark.
UBIQUITOUSWARE is a trademark of FUJITSU LIMITED.
High Safety Required Use
This
This Product
Product is
is designed,
designed, developed
developed and
and manufactured
manufactured as contemplated for general use, including without limitation,
general
general office
office use,
use, personal
personal use,
use, household
household use,
use, and
and ordinary
ordinary industrial
industrial use,
use, but
but is
is not
not designed,
designed, developed
developed and
manufactured
manufactured as
as contemplated
contemplated for
for use
use accompanying
accompanying fatal
fatal risks
risks or
or dangers
dangers that,
that, unless
unless extremely
extremely high
high safety
safety is
is secured,
se
could
could lead
lead directly
directly to
to death,
death, personal
personal injury,
injury, severe
severe physical
physical damage
damage or
or other
other loss
loss (hereinafter
(hereinafter “High
“High Safety
Safety Required
Required
Use”),
Use”), including
including without
without limitation,
limitation, nuclear
nuclear reaction
reaction control
control in
in nuclear
nuclear facility,
facility, aircraft
aircraft flight
flight control,
control, air
air traffic
traffic
control, heavy
heavy
eavy transport
transport logistics,
logistics, medical
medical life
life support
support system,
system, missile
missile launch
launch control
control in
in weapon
weapon system.
system. You
You shall
not
not use
use this
this Product
Product without
without securing
securing the
the sufficient
sufficient safety required
required for
for the
the High
High Safety
Safety Required
Required Use.
Use.
®
About Bluetooth
wireless technology
・Wireless
Wireless
Wireless devices
devices that
that use
use the
the 2.4
2.4 GHz
GHz band
band (as
(as indicated
indicated above)
above) make
make use
use of
of the
the entire
entire bandwidth
bandwidth
and
and are
are unable
unable to
to avoid
avoid using
using the
the bandwidth
bandwidth used
used by
by mobile
mobile identification
identification equipment.
equipment. FHSS
FHSS is
is used
used
as
as the
the modulation
modulation method,
method, and
and such
such devices
devices may
may interfere with other
other devices
devices at
at aa range
range of
of 10
10 m.
m.
・In
In
In addition
addition to
to commercial,
commercial, scientific,
scientific, and
and medical
medical devices (such as microwaves), on
on-premise
premise radio
radio stations
stations (licensed)
(licensed)
and designated low-power
low power
power radio
radio stations
stations (nonlicensed)
(nonlicensed) for
for mobile
mobile identification
identification used
used in
in factory
factory production
production lines and
other
other locations
locations are
are also
also operated
operated within
within the
the frequency band used by this product.
(1
1)Prior
Prior
Prior to
to using
using this
this product,
product, confirm
confirm that
that there are no on
on-premise
premise radio
radio stations
stations or
or designated
designated low-power
low
radio
stations
stations for
for mobile
mobile identification
identification use
use being operated nearby.
(2
2)If
If
If the
the use
use of
of this
this product
product causes
causes radio
radio interference with an on
on-premise
premise radio
radio station
station used
used for
for mobile
mobile
identification, immediately stop the product
productt from
from transmitting
transmitting radio
radio waves,
waves, and
and contact
contact support
support (information
(information
below)
below) to
to discuss
discuss ways
ways to
to prevent
prevent interference
interference (such
(such as
as putting
putting up
up partitions).
partitions).
(3
3)If
If
If the
the use
use of
of this
this product
product causes
causes radio
radio interference with a designated low
low-power
power radio
radio station
station used
used for
for mobile
mob
identification
identification or
or if
if you
you have
have any
any other
other concerns,
concerns, please
please contact
contact the
the source
source this
this product
product was
was obtained
obtained from.
・It
It
It is
is recommended
recommended that
that this
this product
product be
be used
used within a 10 m radius (the line
line-of-sight
sight radius)
radius) from
from devices
devices it
it will
communicate with (the maximum output
output for
for Class
Class 2).
2). However,
However, due
due to
to the
the nature
nature of
of Bluetooth®
Bluetooth® wireless
wireless technology,
technology, the
communication
communication distance
distance may
may vary
vary depending
depending on
on the
the usage
usage environment,
environment, such
such as
as the
the structure/material
structure/material of
of the
the building
building it
is being used in, obstacles, software, installation conditions,
conditions, and
and radio
radio wave
wave conditions.
conditions. There
There may
may also
also be
be situations
situations
where
where communication
communication slows
slows down
down or
or even
even becomes
becomes impossible.
・If
If
If you
you will
will be
be using
using this
this product
product on
on an
an airplane,
airplane, first
first contact
contact the
the relevant
relevant airline
airline company
company to
to confirm.
confirm.
・We
We are not to be held responsible
responsible for
for any
any data
data transmitted
transmitted nor
nor information
information leaked
leaked during
during Bluetooth®
Bluetooth® wireless
wireless technology
technology
communication.
Wireless LAN (WLAN)
・The
The product uses the 2.4 GHz band. DS-SS
DS SS
SS and
and OFDM
OFDM are
are used
used as
as the
the modulation
modulation schemes.
schemes. The
The
interference distance is about 40 m or less.
All
All bandwidths
bandwidths can
can be
be used,
used, and
and that
that bands
bands of
of mobile
mobile unit
unit identification
identification devices
devices can
can be
be avoided.
avoided.
(1
1)In
In
In the
the frequency
frequency band
band used
used by
by WLAN
WLAN devices,
devices, in
in addition
addition to
to home
home electric
electric appliances
appliances such
such as
as aa microwave
microwave oven
and industrial/scientific/medical
industrial/scientific/medical devices, in-plant
in -plant
plant
plant radio
radio stations
stations for
for identification
identification of
of mobile
mobile objects
objects used
in
in production
production lines
lines of
of aa factory,
factory, etc.,
etc., specified low power radio stations or
or amateur
amateur radio
radio stations
stations can be
in operation.
(2
2)Before
Before using this device, confirm that in-plant
in plant radio
radio stations
stations for
for identification
identification of
of mobile
mobile objects,
objects, specified
specified
low
low power
power radio
radio stations
stations or
or amateur
amateur radio
radio stations
stations are
are not
not in
in operation
operation in
in your
your neighborhood.
neighborhood
(3
3)If
If
If this
this device
device generates
generates harmful
harmful radio
radio wave interference against in
in-plant
plant radio
radio stations
stations for
for identification
ide
of
of mobile
mobile objects,
objects, change
change the
the using
using frequency
frequency promptly
promptly or
or stop
stop using
using wireless
wireless LAN
LAN function.
function.
(4
4)If
If
If the
the use
use of
of this
this product
product causes
causes radio
radio interference with a designated low
low-power
power radio
radio station
station used
used for
for mobile
mobile
identification or if you have any other
otherr concerns,
concerns, please
please contact
contact the
the provider
provider of
of this
this product.
product.
・It
It
It is
is recommended
recommended that
that this
this product
product be
be used
used within
within aa 25
25 mm radius
radius (unobstructed)
(unobstructed) from
from devices
devices it
it will
will communicate
communicate with.
However,
However, due
due to
to the
the nature
nature of
of wireless
wireless LAN
LAN technology,
technology, the communication distance
distance may
may vary
vary depending
depending on
on the
the usage
usage
environment,
environment, such
such as
as the
the structure/material
structure/material of
of the
the building
building it
it is
is being
being used
used in,
in, obstacles,
obstacles, software,
software, installation
installation
conditions, and radio wave conditions.
・There
There
There may
may also
also be
be situations
situations where
where communication
communication slows down or
or even
even becomes
becomes impossible.
impossible.
・In
In
In mixed
mixed IEEE
IEEE 802.11g
802.11g and
and IEEE
IEEE 802.11b
802.11b wireless
wireless LAN
LAN environments,
environments, IEEE
IEEE 802.11g
802.11g functions
functions may
may not
not be
be available
available in
in order
to
to maintain
maintain compatibility
compatibility with
with IEEE
IEEE 802.11b
802.11b standards.
standards. If
If IEEE
IEEE 802.11g
802.11g functions
functions are
are required,
required, keep
keep IEEE
IEEE 802.11g
802
and
IEEE
IEEE 802.11b
802.11b networks
networks separate,
separate, and
and leave
leave at
at least five channels open
open between
between the
the channels
channels used
used at
at each
each network.
network.
All other trademarks specified here are
the property of their respective owners.
Copyright FUJITSU LIMITED 2016
201
■ To users of this product
■ Power ON/OFF
This product’s functions and use may vary depending on how it was configured by the
source it was obtained from (the business customer that purchased the product from
us).
Please ask for an explanation of this product’s functions and use when you receive
the product, or contact the source the product was obtained from for help.
□ Power ON
revent entry or theft. We are not to be held responsible for incidents,
* This product is not meant to p
prevent
accidents, or damage caused through use of this product.
* This
This product
product is not meant for specialized monitoring such as childcare, caregiving, or medical purposes.
We are not to be held
held responsible for incidents, accidents, or damage caused through use of this product
for these applications.
□ Power OFF
Remove the power supply plug of the AC adapter from an outlet.
■ Confirm included items prior to use
Prior to using this product, confirm that the following items are included in the package. If anything is missing,
please
please contact
contact the
the source
source the
the product
product was obtained from. In addition to the included items listed on this sheet,
the package may also contain a sheet of instructions. Place the included items along with the sheet of instructions
in safekeeping.
○ Remote Monitoring Station(main unit)
○ Precautions to use (this sheet)
○ AC Adapter
○ Power cable
○ Warranty Card Confirm that all product serial numbers are entered on the warranty card.
In addition, the attached articles of the stand for RCB sold separately are as follows.
○Stand
Stand ○Screw ○Double-sided
○
Adsorption tape x2
tape x2 ○
○Adsorption
1.
2.
Installation of Remote Monitoring Station
■
* If
If you
you were
were provided
provided with
with any
any installation
installation instructions
instructions from
from the
the provider
provider of
of this product, be sure
to follow them.
Install the Remote Monitoring Station according to the environment it will be used
in.
in. We
We recommend
recommend using
using the separately sold stand or wall attachment options to install
onitoring Station
tation.
. Commercially sold tripods or other fixtures (that use
the Remote
emote Monitoring
1/4th inch screws) can be installed using the screw hole on the bottom of the main
unit.
This
This section
section explains how to install the stand (sold separately).
For
For information
information on
on how
how to install the wall attachment, please refer to the manual
supplied with the wall attachment.
1.
■ Ports and controls – main unit □ Front
Power cable
Connect the Power cable to an AC adapter.
cable to the DC-IN
DC IN connector of the product
Connect the Power
and connects the power supply plug of the AC adapter to an
outlet. Then power of Remote
Remote Monitoring
onitoring Station turns on. A
power LED turns on green in a short time.
AC Adapter
Set the power cable in the cable gu
guide.
Cable sticking out from bottom
Cable sticking out from back
Emergency Call
all Button
Consulting Call Button
Camera [Note]
Call Cancel Button
Power LED
Camera LED
Mic
Thermohygrometer sensor
Pyroelectric sensor
Mic
Status LED
Speaker
2.
Cut side
Note: only the model mounted camera
Note 1: The thick tape is Adsorption tape;; the thin tape
ouble-sided tape.
is Double
Note
Note 2:
2: Clean
Clean any
any dirt
dirt or
or dust
dust from
from the bottom surface
of
of the
the stand
stand prior
prior to
to attaching
attaching the tape.
WLAN Connect LED
□ Rear
BLE Pairing LED
WLAN Connect Button
BLE Pairing Button
Cable guide
Volume Button
Peel the paper from the Adsorption tape
sided tape, and
tape or the cut side of the Double-sided
then stick the tape to the bottom surface of the stand.
3.
Attach here
Install the stand to the Remote Monitoring Station.
Use a coin to tighten and loosen the screw.
Power Connector
Screw hole for the stand
Line the screw holes up and fasten
them with a screw.
□ Bottom
Do not install slanted.
Screw hole
4.
Peel the film from the Adsorption tape (or paper from the non-cut side of the Double-sided
tape), attach it firmly to the adhesion surface, and then install the Remote Monitoring
Station.
Note the following during installation.
Install on a flat surface with no irregularities.
Remove any dirt, water, or oil from the installation location prior to installation.
Do not attach double-sided tape to locations with weak surfaces such as wallpaper.
When double-sided tape is removed it may leave a mark. If using a chemical such as an adhesive
remover to clean the surface, make sure that it will not cause any damage.
injury due to the damaged part.
Store bags and the like used for the
packaging material outside the reach of
children.
Doing otherwise could result in suffocation if the
child puts the material in his or her mouth or covers
■ Safety Notes
his or her head with it.
This section includes important information in order to use this product safely and correctly. Be sure to read this
Do not insert or remove the power cable or
information prior to using this product, so that it can be used correctly, safely, and appropriately. Be sure to read
AC adapter if your hands are wet.
cables, or power plugs.
the manual carefully in order to use the product correctly.
Doing otherwise could cause electrical
Doing otherwise could cause fire or
shock.
Common notes for UBIQUITOUSWARE products
Do not wrap the power cable tightly around
outside the reach of infants.
Do not allow infants to chew or swallow the
main unit or its accessories.
Always be sure to turn this product off
prior to entering areas (such as gasoline
If an infant should swallow the main unit
stands) with flammable gas (such as
propane gas or gasoline) or dust. Do not charge the
power cable. Do not place heavy objects on
outlet, do not catch anything on it or
it, or bend or twist it unreasonably. Do not
otherwise subject it to strong impact.
Doing otherwise could cause injury or a malfunction.
Do not drop the AC adapter or subject it
fire.
damage the internal circuit board. Do not
use deformed, broken, or damaged AC adapters or power
CAUTION
Do not wipe with benzine or paint
cables.
Doing otherwise could cause a malfunction,
electrical shock, or fire.
forces, drop it, drive nails through it,
thinner.
Periodically remove the AC adapter or
hammer it, or step on it.
Doing otherwise could cause paint
power plug from the outlet, and use a soft
Doing otherwise could cause ignition, damage, or
peeling, cracking, injury caused by damage, or a
injury.
fire.
If this product is dirty or wet, wipe it
it, or short the terminals.
clean with a dry cloth or the like.
Doing otherwise could cause smoke,
If left dirty or wet the product could
ignition, or an explosion.
Using the product when these are dusty could cause
electrical shock, burns, or fire. Inspect and clean
the product once per year.
Always remove the AC adapter power plug
deteriorate more quickly or its color could fade.
If this product behaves abnormally (such
Do not place heavy objects on this
as heat buildup, emitting smoke or
product.
strange odors/noises), immediately
remove it from your wrist and turn the power off.
cloth to clean dust from the connecting
parts of the outlet, AC adapter, and power cable.
Do not place this product in fire, heat
Doing otherwise could cause damage or
If the product is connected to its AC adapter,
Do not use or place this product in
remove the power plug from the outlet.
locations that are subject to direct
Continuing to use this product when it is acting
sunlight or that are very hot (such as in
abnormally could cause electrical shock or a fire.
from the outlet during maintenance.
Doing otherwise could cause electrical
shock.
Never use in bathrooms or other highly
injury.
humid locations.
Doing otherwise could cause electrical
shock or a malfunction.
locked vehicles).
If the product will not be used for a long
If a liquid (such as water) or a foreign
Doing otherwise could cause an electrical shock or
period of time, remove the AC adapter
substance (such as metal) enters this
fire. It could also result in damage or a
product, immediately turn the product
malfunction.
off. If the product is connected to its AC adapter,
remove the power plug from the outlet.
Continuing to use it in this state could cause
electrical shock or a fire.
AC Adapter, Power cable
WARNING
Use only at the specified power supply
as its cover are damaged, immediately
voltage.
turn the product off and repair it.
electrical shock or a fire.
Failure to do so could cause ignition,
fire, heat buildup, or electrical shock.
square waves (uninterruptible power
product or its cables until there is no
Do not connect any cables as long as there is a danger
of lighting striking. If there is a danger of
supplies (UPS) or automobile AC power
supplies).
Doing otherwise may result in a fire.
lighting striking, turn this product off beforehand
Make sure that the power plug is firmly
and immediately remove the product from your wrist.
inserted all the way into the outlet.
If the product is connected to its AC adapter, remove
If the connection is not good it could
the power plug from the outlet and then detach the
cause electrical shock, heat buildup, or ignition
cables.
that could result in a fire. Do not use any loose
Doing otherwise could result in being shocked by
outlets.
lightning or could cause a fire. The product could
Insert the AC adapter power plug directly
also malfunction.
and firmly into the outlet (100 V AC). Do
Never disassemble or modify this product
not use piggybacked electrical outlets.
yourself.
Doing otherwise could cause electrical shock, burns,
Doing otherwise could result in injury,
or fire.
electrical shock, or a fire.
Hold the AC adapter or power cable straight
When using this product, do not cover it
with a blanket or other covering, place
it near a heater, or place it on an
electric carpet.
when inserting or removing them. Do not
apply unreasonable force.
Doing otherwise could cause fire, burns, injury, or
electrical shock.
Doing otherwise could trap heat inside the product,
causing a fire.
When removing the AC adapter power plug
from the outlet, be sure to grab the AC
Do not use cleaning sprays (that include
adapter. Do not pull the power cable.
flammable substances) to clean this
Pulling the power cable could damage it, causing
product.
electrical shock or fire.
Doing otherwise could result in a malfunction or
fire.
Place the product near the outlet in an
accessible location where the power plug
If this product is damaged and the main unit’s
can easily be reached.
internals are exposed due to dropping it or the like,
Doing otherwise could make it impossible to remove
do not touch the exposed internals.
the power plug or could lead to danger.
Doing otherwise could cause electrical shock or
circuit, fire, or burns.
Radio components
WARNING
Precautions on WLAN and
®
Bluetooth wireless technology
Turn wireless communication
functions off (for example, turn the product
off) in the following locations.
・Inside hospitals or in locations with
electronic medical devices
Be especially careful not to bring the
product into operating rooms, intensive
care units, CCUs (coronary care units), or
other similar locations.
・Locations where the use of wireless
communication functions is prohibited,
such as on airplanes
・Near automatic control devices such as
automatic doors or fire alarms
・Locations where you may come into close
contact with individuals who are wearing
implantable medical devices (such as
pacemakers) in the situation where you
cannot move freely, etc.
power plug from the outlet and disconnect
the AC adapter.
■ Disposal
CAUTION
For commercial customers who have purchased the product from us, refer to “Disposing
and Recycling ICT Products” on our webpage
(http://www.fujitsu.com/jp/about/environment/society/products/recycleinfo/). If this
product was obtained from another source, please contact that source.
Do not connect to devices that generate
If you hear thunder, do not touch this
danger of lighting striking.
Doing otherwise could cause electrical shock, a short
Doing otherwise could cause a fire.
If this product is dropped or parts such
Continuing to use it in this state could cause
use damaged cables.
to strong impact. Doing otherwise could
Doing otherwise could cause an electrical shock or
Do not subject the product to strong
Do not damage, modify, heat, or pull the
with a physician.
with other products.
ignition, an explosion, a malfunction, or
electrical shock.
When the AC adapter is connected to the
use the included AC adapter or power cable
leaking.
Doing otherwise could cause fire or
or its accessories, consult immediately
or power cables with this product; do not
Doing otherwise could cause heat buildup,
objects near the AC adapter power plug.
pressure to the base.
Doing otherwise could expose or sever the core of the
Use only included or specified AC adapters
Doing otherwise could cause the gas to ignite.
Do not bring screwdrivers or other metal
the AC adapter, or otherwise apply
power cable, causing electrical shock or fire.
product in these areas.
Use indicated peripheral devices only.
electrical shock.
Store the main unit and its accessories
DANGER
WARNING
Do not use damaged AC adapters, power
■ Additional Information
□ Precautions for use
・This product uses wireless communication, and there may be cases where functions may not be used
as expected if there is cross talk or interference. We are not to be held responsible for incidents,
accidents, or damage caused through use of this product.
・If the status LED turns red, a sensor malfunction or communication error may have occurred. If this
occurs, please contact the source this product was obtained from.
・A smartphone (Android 4.4 or later) and special application are required to initialize this product.
・No personal information is stored in this product.
・This product cannot be used if it is not turned on.
・Place one hand on the Remote Monitoring Station to stabilize it when pressing buttons. Doing otherwise
could cause the adhesion side of the stand to come unstuck, making it impossible to press buttons.
・The wireless LAN IEEE 802.11b unit installed in the Remote Monitoring Station can use wireless
channels 1 through 13. Set the wireless LAN access point to use a channel within the range from
1 to 13. Please refer to your wireless access point manual for information on how to configure
it.
■ FCC CAUTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This transmitter must not be co
co-located
located or operated in co
conjunction
njunction with any other antenna
or transmitter.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are design
designed
ed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by tu
turning
rning the equipment
equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
—Reorient
Reorient or relocate the receiving antenna.
—Increase
Increase the separation between the equipment and receiver.
—Connect
Connect the equipment into an ou
outlet
tlet on a circuit different from that to which the
receiver is connected.
—Consult
Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment
should be installed and operated keeping the radiator at least 20cm or more away from
person’s body.
■ IC CAUTION
■ Detailed information
□ Function List
In order to use this function, “UBIQUITOUSWARE Sensor Algorithm” (sold separately) is required.
・Product function
Function
Specification
Application Example
Safety confirmation
Trespassing prevention
Safety confirmation
Health monitoring
Sound detection
Detects conversation and speech of the person.
Snoring detection
Detects snore frequency/interval.
Disturbance
detection of
respiration
Detects the length of the long silence interval between snoring. Health monitoring
Cough detection
TV sound detection
Sound pressure
measurement
Abnormal big sound
detection
Temperature and
humidity measurement
The estimate of the
thermal environment
level
Notice of the degree
of risk of the heat
stroke
Detection of
human body motion
Detects a high frequency of consecutive coughs.
Safety confirmation
Detected as positive if at least 10 sets of consecutive coughs (i.e.
Health monitoring
20 coughs) are detected in an hour.
Detects the sound spreading from TV.
Safety confirmation
Abnormal big sound
Measure the mean of the sound pressure per minute.
(Big sound detection)
Abnormal big sound
Notifies the event of big sound pressure as abnormality.
(Big sound detection)
Trespassing prevention
Measure the temperature / the humidity.
Estimates the thermal environment level on a scale of 1 to 5 from
the heat index that is based on heat and humidity information
measured by the thermo-hygro sensor.
If the thermal environment level is high, the administrator is
notified and the terminal automatically plays an announcement
urging that measures be taken.
Uses a motion sensor to detect human movement in order to determine
whether or not someone is in the vicinity.
Heat index measurement warning
Heat index measurement warning
Heat index measurement warning
Safety confirmation
Trespassing prevention
Safety confirmation
(As confirmation means of the
situation)
Camera
The image photography of the still image is possible.
Abnormal big sound detection
(As confirmation means of the
situation)
Trespassing prevention
Notifies/Alerts to the administrator by only pushing the Emergency Emergency Call / talk
VoIP call originating
Call or Consulting Call Button.
Consulting Call Button
Emergency Call / talk
VoIP call incoming
Receives VoIP calls made by administrators.
Consulting Call Button
Sends notification that the Emergency Call button or Consulting Call
Notification
Emergency Call / talk
Button was pressed (must select VoIP call transmission for each
transmission
Consulting Call Button
button, and then make a call).
Pressing the Call Cancel Button cancels abnormality notification.
If the Emergency Call Button or Consulting Call Button is pressed
Cancel
accidentally, or if an abnormality is erroneously detected, the user
can prevent the call from connecting or a photo from being taken.
Five audio files are stored in the terminal as means of communicating
Simultaneous
with the user. Sounds can be played back at the direction of the
announcement of
Announcement
administrator.
the sound
It is possible to update audio files over the network.
Turns on/off the trespassing prevention mode.
Trespassing
When the sound or motion sensor detected it in absence, notifies
Trespassing prevention
prevention mode
the trespassing event to a server and beeps alarm sound.
And takes a picture and uploads it to a server.
Controls On/OFF of the trespassing prevention mode by setting the
Trespassing
date and time.
prevention mode
Turns on the trespassing prevention mode automatically when it is
Trespassing prevention
with the date and hour past the designated date and time,
designation
*Please turn off the trespassing prevention mode beforehand when
turning on this mode.
The firmware update
Downloads the firmware of the Remote Monitoring Station from a
of the Remote
The firmware update
server and updates it.
Monitoring Station
* Please see the FUJITSU IoT Solution UBIQUITOUSWARE General Catalog for actual examples of usage scenarios.
・Cooperation function with the vital sensing band
Function
Bluetooth
out-of-range
notification
Transfer function of
the sensor data of the
vital sensing band
Firmware update
function of the vital
sensing band
Specification
Application Example
Detects when Vital Sensing Band's Bluetooth connection drops, and
can notify the administrator that the user has moved away from the Out-of-range notification
Remote Monitoring Station.
Collects sensor data via Bluetooth from the vital sensing band and
uploads it to a server.
Downloads the firmware of the vital sensing band from a server and
transmits data to it via Bluetooth.
The firmware update.
□ Sound playback function
・Customizing the audio file
The audio file played over the Remote Monitoring Station and each function sound can be customized over the network.
List of sounds that can be configured
No.
Type
Length
Usage
Playback
Stop
Volume
Priority
Default
announcement
message
"There has been an
earthquake. Please
act calmly. Stay safe
and extinguish the
source of the fire.
Please check the TV
or radio for
information and stay
calm." (Assuming
there has been an
earthquake)
"A heavy rain and
flood warning has
been issued. Please
check the weather
forecast for
updates." (Assuming
there is heavy rain
and flooding)
"A disaster has
occurred happened in
your residence area.
Please check
information on TV or
radio and act calmly.
(Assuming there has
been a disaster)
"There has been a
disaster in your
region. Please
evacuate to the
specified evacuation
site." (Assuming
there has been a
disaster)
"The earlier
announcement was
false alarm".
Announcement 90sec
Information provision Playback
Stops after
announcement
request from repeating
the service twice
provider
Set
volume
Announcement 90sec
Information provision Playback
Stops after
announcement
request from repeating
the service twice
provider
Set
volume
Announcement 90sec
Information provision Playback
Stops after
announcement
request from repeating
the service twice
provider
Set
volume
Announcement 90sec
Information provision Playback
Stops after
announcement
request from repeating
the service twice
provider
Set
volume
Announcement 90sec
Stops after
repeating
twice
Set
volume
Announcement 10sec
prior to a
photo shoot
Information provision Playback
announcement
request from
the service
provider
Playback
Announcement sound
played prior to
request from
shooting with the
the service
provider
camera according to
instructions from the
service provider
Playback
completion
Set
volume
Shutter
sound
Camera sound when
shooting with the
camera
Playback
completion
Set
volume
"It will take a photo
of you right after
this announcement.
Please press the Call
Cancel Button if it's
unnecessary.
3.2.1"
Shutter sound
Volume
1sec
change sound
Playback
completion
Set
volume
Volume change sound
1sec
Confirmation sound
played when a Volume
Button (+)/(-) is
pressed
• After the
announcement
prior to a
photo shoot
is complete
• After the
service
provider
requests a
photo shoot
When a Volume
Button
(+)/(-) is
pressed
No.
Type
Length
Usage
Playback
Confirmation sound
played when the Call
Cancel Button is
pressed
Chime sound played
prior to playing an
information
announcements/thermal
environment level
announcement
When the Call
Cancel
Button is
pressed
Announcement
1-5 /
Prior to
thermal
environment
level
announcement
When a
thermal
environment
level of 4 or
5 is detected
* After
playing the
chime sound,
an alert
announcement
must be made.
After
sending a
photo when an
intrusion
was detected
Cancel sound 2sec
10
Chimes sound 5sec
11
Thermal
20sec
environment
level
announcement
Thermal environment
alert announcement
12
Alarm sound
5sec
Alarm sound played
when an intrusion is
detected
13
Emergency
Call Button
15sec
14
Received
20sec
call
announcement
15
Consulting
10sec
announcement
16
Ring back
tone
5sec
Stop
Volume
Priority
Playback
completion
Set
volume
Playback
completion
Set
volume
---
Stops after
Set
repeating
volume
twice (can be
set to repeat
from 1 to 10
times))
• After
repeating for
10 minutes
• When the
trespass mode
is OFF
• When
abnormality
detection
status is OFF
Announcement sound
After
• When
played until a call is pressing the incoming call
received from the
Emergency
received from
center, after the
Call Button the center was
Emergency Call Button * Repeats
automatically
is pressed
until the
answered
stop
• When cancel
condition
is pressed
• When time
has passed (5
minutes)
Announcement sound
When there is ・Playback
played until a call is an incoming completion
received from the
call
・When the Call
center, after the
Cancel Button
Consulting Call Button
is pressed
is pressed
After
• When
Announcement sound
played until a call is pressing the incoming call
received from the
Consulting
received from
center, after the
Call Button the center was
Consulting Call Button * Repeats
automatically
is pressed
answered
until the
stop
• When cancel
condition is is pressed
reached
• When time
has passed (5
minutes)
Outgoing call ring
When there is • When the
back tone
an outgoing center has
call
responded
• When cancel
is pressed
• When an
outgoing call
failed
Default
announcement
message
"Your request has
been canceled."
Chimes sound
"You have a risk to
get heat stroke in
this room.
Please take some
water, make the room
cooler etc. to avoid
the risk. "
Maximum
volume
(Level
5)
Alarm sound
Set
volume
"Emergency Call
Button has been just
pressed.
It's connecting now
so please wait a
while. "
Set
volume
"Receiving a call.
Please hold on.
Please press the Call
Cancel Button if it's
unnecessary. "
Set
volume
"Consulting Call
Button has been just
pressed.
It's connecting now
so please hold on a
minute. "
Set
volume
Ringing tone
* One with a small figure is reproduced by priority.
* It reproduces in the winning when the same priority reproduction demands are generated.
Sound data that can be played on this product is PCM format.
- sampling rate:16000Hz
- bit sample:16 bit
- number of channels:1ch(monaural)
- volume level:The largest level where a waveform clip is not generated is recommended.
Please edit the sound source by using the sound edit software to become the above-mentioned condition.
□ Limitations of each sensing
Mic
・May detect sounds from sources other than people. For example, sounds from dogs or cats may be detected as voices.
・If used with a window left open, sounds from outside may make it difficult to detect human voices, or the device
may react to human voices from outside.
・Detection performance
- It detects it when there is 5 dB or more sound pressure difference between a surrounding noise and the sound
to be detected.
- Detects audio when audio to detect is 65 dB or higher (for voices, coughs, and TV audio).
- Detects audio when audio to detect is 60 dB or higher (for snoring and disturbance of respiration).
- Detects audio when audio to detect is 95 dB or higher (for detecting loud noises).
- Detection area: Horizontal: approx. 180 degrees, Vertical: approx. 180 degrees Distance: approx. less than 5
m (in case of voice, cough and TV sound. In the case of snoring and disturbance of respiration, it is less than
50cm)
Motion sensor
・Sensor that detects moving objects with a temperature difference from the surroundings. Moving objects other than
people may therefore be detected as people. Some examples include animals, opening/closing doors, curtains moving
in the wind, air coming from air conditioners, steam rising from electric water heaters, and swiveling electric
heaters.
・Detection performance
- Detects objects with a +4°C difference in temperature from the surroundings (with a size of around 150 cm x 30 cm)
that have moved in a horizontal direction at a speed of around 1.0 m/s.
- Detection area: Horizontal : approx. 120 degrees, Vertical : approx. 90 degrees, Distance : approx. less than
8 m
Camera
・Performance
- Shooting range : Horizontal : approx. 70 degrees, Vertical : approx. 40 degrees
- Approx. 900 K pixels ( 1280x720)
・Other
- Photographing in a dark place is not possible.
- After a photo is taken, it may take up to two minutes to upload it (depending on the communication environment
and server environment). Other functions such as the Emergency Call Button, Consulting Call Button, or receiving
calls cannot be used during this time.
- Zoom and photographing in a dark place are not possible.
- The camera and call functions cannot be used at the same time. If the Consulting Call/Emergency Call Buttons
are pressed or if a call comes in when the camera is taking a photo, the camera shooting will be canceled.
- When a VoIP call is received or made, or when waiting for a call after pressing the Consulting Call Button, the
shooting instruction will be discarded.
Thermo-hygro sensor
- It takes 30 minutes to start of measurement after power on.
Call Cancel Button
- Cannot use the Emergency Call, Consulting Call and Call Cancel Button for 2 seconds after pushing a button.
10
□ Main unit operation (Gateway Software Configuration Tool)
Operation items
Setting of Remote Monitoring Station
Overview
Configure the Remote Monitoring
Station.
Remarks
Please refer to the appendix in the User's
Guide (Gateway/Device Settings Version) for
settings.
Remote Monitoring Station diagnosis
└ WLAN connection status
└ Server connection status
└ Pyroelectric sensor status
Confirm operation of the Remote
Monitoring Station.
└ Trespassing prevention mode
└ Camera shooting
Edit/send whitelist
Manage a Vital Sensing Unit to connect The server URL, login ID, and password will
with a Remote Monitoring Station。
need to be configured in the application.
Device settings
└ Device ID
Configure a Vital Sensing Unit
connected with a Remote Monitoring
└ Vital algorithm function settings
Station.
└ Vibration settings
└ Motion function operation settings
└ Pulse sensor parameter settings
※ For more details, refer to the "User's Guide (for Main Module) / (for Gateway and Device Setup)" attached
"UBIQUITOUSWARE Sensor Algorithm".
to the
11
□ Main unit operation (Device Management Tool)
Operation items
Device / Gateway / Remote Monitoring Station List
Overview
Display the list of Device / Gateway / Remote Monitoring
Station.
On clicking a device ID or a gateway ID or a station ID in the
Checking Contents of Device / Gateway / Remote Monitoring "Device/Gateway/Remote Monitoring Station List," you can check
Station
the data contents that are set for that ID.
(For single device / Gateway)
Edit the value of set item of Device / Gateway / Remote
Batch Editing Devices / Gateways / Remote Monitoring Stations Monitoring Station at once.
(For multiple devices / Gateways)
Display the history of control command of Device / Gateway /
Command History
Remote Monitoring Station.
(Display for each request number)
Display the detailed information of control commands to the
Device / Gateway / Remote Monitoring Station.
Detailed Information of Control Commands
(Display the result of the process, etc. to each Device / Gateway
/ Remote Monitoring Station)
Display the list of uploaded log files from the Device / Gateway
List of uploaded log files
/ Remote Monitoring Station.
IoT Platform Setting
Set the connection information to the platform.
Command Create New
■Getting Log
■Firmware Update
■Camera Shooting
■Mode Change
■Sound Data Download
■Sound Data Playback
■Alarm Release
■Remote Monitoring Station Reset
■Certificate Download
The following can be directed.
* The Device in this item refers to Vital Sensing Unit.
* The more information of this tool can be found in the (Sensor Algorithm User's Guide (for Main Module)(Device and Gate Way
Setting)).
□ Setting method when function is not used
Function
Operation
All call functions(Incoming and
outgoing)
Do not configure the telephone number after configuring the setting when the Consulting
Call button is pressed and the setting when the Emergency Call Button is pressed to "call."
Call function by Consulting Call
Button
Do not configure the consulting report contact telephone number after configuring the
setting when the Consulting Call Button is pressed to "call."
Call function by Emergency Call
Button
Do not configure the emergency report contact telephone number after configuring the
setting when the Emergency Call Button pressed to "call."
Temperature and humidity
measurement
Turn off the thermo-hygro sensor ON/OFF.
Trespassing prevention
Turn off the Trespassing prevention mode OM/FF and the Trespassing prevention mode with
the date and hour designation.
Safety confirmation
Turn safety confirmation OFF in the sensor algorithm settings.
Out-of-range notification
Turn out detection mode OFF.
Camera shooting
There is no setting to turn the function OFF.
To prevent the camera from taking photos, the administrator should not issue a shooting
instruction, or the trespassing prevention mode should be turned OFF. If the trespassing
prevention mode is ON it will automatically take photos.
To completely disable the camera shooting function, use a Remote Monitoring Station (No
Camera).
12
□ Product operation ( Button )
・Normal button operation
Status
Emergency
Call Button
Short
push
During/Under
normal
operation
During
emergency
report /
During
consulting
report /
During
announcement
During VoIP
call
During
trespassing
prevention
mode
During
camera
photographin
During
firmware
update
Out-of-servi
ce
Configuring
product from
smartphone
over a
Bluetooth
connection
During
Bluetooth
setting
Emerge
ncy
call
Push
and
hold
Consulting
Call Button
Short
push
VoIP
incomi
ng
Push
and
hold
Call Cancel
button
Short
push
Push
and
hold
BLE Pairing
Button
WLAN Connect
Button
Volume
Button(+)
Volume
Button(-)
Short
push
Push
and
hold
Short
push
Push
and
hold
Short
push
Push
and
hold
Short
push
Push
and
hold
WLAN
connec
tion
Volumeup
Volume
-up
Volumedown
Volume
-down
Blueto
oth
pairin
g with
smartp
hone
Volumeup
Volume
-up
Volumedown
Volume
-down
Cancel
( VoIP
call/
camera
photog
raphy
Volumeup
Volume
-up
Volumedown
Volume
-down
Volumeup
Volume
-up
Volumedown
Volume
-down
Emerge
ncy
call
VoIP
incomi
ng
Volumeup
Volume
-up
Volumedown
Volume
-down
Emerge
ncy
call
(*1)
Emerge
ncy
call
(*1)
Volumeup
Volume
-up
Volumedown
Volume
-down
Volumeup
Volume
-up
Volumedown
Volume
-down
VoIP
incomi
ng
test
Blueto
oth
pairin
g with
smartp
hone
WLAN
connec
tion
Volumeup
Volume
-up
Volumedown
Volume
-down
VoIP
incomi
ng
Volumeup
Volume
-up
Volumedown
Volume
-down
Volumeup
Volume
-up
Volumedown
Volume
-down
Emerge
ncy
call
test
Emerge
ncy
call
During WLAN
setting with
the WLAN
connection
button
WLAN
connec
tion
Blueto
oth
pairin
g with
smartp
hone
* Five volume levels are available (level 1 to level 5). Pressing the Volume Buttons (+)/ (-) will increase or decrease the
volume step by step.
*1: Emergency call and VoIP incoming are possible only when the firmware data is downloaded. But the firmware download
is cancelled.
13
・Plural button operation
WLAN Connect & BLE Pairing Button
Power-on with pushing both buttons at the same time
WLAN Connect & BLE Pairing Button
Status
Short push
Push and hold
Short push
Push and hold
During/Under
normal operation
Reset to factory default
Bluetooth pairing with the Vital Sensing
Unit
During emergency
report / During
consulting report /
During
announcement
During VoIP call
Bluetooth pairing with the Vital Sensing
Unit
Bluetooth pairing with the Vital Sensing
Unit
During trespassing
prevention mode
During camera
photographing
During firmware
update
Out-of-service
Configuring
product from
smartphone over a
Bluetooth
connection
During Bluetooth
setting
During WLAN setting
with the WLAN
Connection Button
14
□ LED list
LED
Status of main unit
Status of LED
Calling
Status LED
(Green and Red)
Emergency announcement
Green flashing
Dangerous
Heat
Disorder
announcement
Talking
Green lights
Equipment abnormality occurs in
Red flashing
During a firmware update
Green fast flashing
Power LED
(Green)
Power ON
Lighting
Power OFF
Turning lights off
Camera LED
(Green)
Camera use
Lighting⇒20 seconds after off
Camera unused
Turning lights off
WLAN setting in
Green flashing
WLAN setup complete
Green lights⇒3 seconds after off
Network communication possible
Green lights
WLAN Connect LED
(Green)
Pairing in
BLE Pairing LED
(Green and Red)
Green flashing
*Up to 30 seconds
Pairing establishment
Green lights⇒3 seconds after off
Pairing failed
Red flashing⇒3 seconds after off
* All LED is turned off when the power supply of the main unit is off.
* When the WLAN is cut in the out of the sphere etc. after the WLAN is connected, the WLAN Connect LED is turned off.
* The BLE Pairing LED does not light while connected it after the BLE pairing succeeds.
* The Status LED might seem flashing to orange if equipment abnormality occurred while the Status LED is lighting or flashing
to green.
* When the Status LED has flashed in red or orange, an equipment abnormality occurs. Please put the power supply of the main
unit again.
□ Connection of external devices
Capable of connecting external devices
UBIQUITOUSWARE Vital Sensing Unit
・The maximum number of connections to a single Remote Monitoring Station : 4
・Connection method : Select from the connection by the pairing and by the whitelist
15
Remote Monitoring Station
Instruction Manual (detailed version)
Published by FUJITSU LIMITED
Information on the product description meets the
design specifications of Fujitsu and is provided for
comparison purposes.
Several factors may cause the actual results to
differ.
Technical data is subject to change without prior
notification. Fujitsu rejects any responsibility
with regard to technical or editorial mistakes or
omissions.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 17
Producer                        : iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.0 ©2000-2013 iText Group NV (AGPL-version)
Create Date                     : 2016:10:26 18:02:23+09:00
Modify Date                     : 2016:10:26 18:02:24+09:00
Title                           : 
Subject                         : 
Creator                         : CubePDF
Author                          : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EJE-IOT008

Navigation menu