Fujitsu 1FINITY S100 Switch
User Manual: Fujitsu 1FINITY S100 Switch FNC Resources — Data Sheets - Fujitsu United States
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
Data Sheet 1FINITY™ S100 Switch Layer 2 switch delivers dense Ethernet aggregation S100 Blade at a Glance • Modular 1RU blade design • 1.2 Tbps switching capacity • Four front-access slots for several combinations: 12 × SFP+ 10 GbE/OTU2 3 × CPF4 100 GbE 12 × SFP+ 1 GbE/10 GbE 1 × 100G NBO CFP2-ACO* • Web-based GUI, CLI scripts, or NETCONF API Product Overview The 1FINITY S100 Layer 2 switch is a compact, carrier-grade platform that delivers dense 1 GbE or 10 GbE to 100 GbE aggregation in a 1RU blade. The S100 solves space and power challenges, delivers high-performance scalable services, and reduces operating costs. Solving the Problems of Convergence Optical and switching technologies are advancing rapidly, and new platforms often integrate the two. In recent years, vendors have created sophisticated, converged, chassis-based platforms. This approach has been successful, but it has also inflated initial costs; slowed innovation; reduced space efficiency and physical flexibility; and encouraged vendor lock-in. Solutions to these problems can be found in a modular, disaggregated product that employs pluggable elements. One of these is the 1FINITY™ S100 Switch, an innovative, modular Layer 2 switch that combines high density and simplicity. Modular Blade-Based Design The modular design results in maximum pay-as-you-grow flexibility. This design offers efficient scaling by adding additional 1RU systems as needed. The small, dense form factor allows full utilization of rack space in 1RU increments, and the absence of a large, multislot chassis eliminates the need for rack partitioning. Page 1 of 4 Operationally, the 1FINITY architecture is as close as possible to zero intercept—with no chassis, there is zero space and zero cost prior to initial service. The modular design enhances availability by minimizing Mean Time To Repair(MTTR), since most sources of failure can be quickly repaired. Additionally, the blade-based design is future-proof and evergreen; users can upgrade modules as new technology becomes available. Finally, with support for open optics, purchases can be made from Fujitsu or directly from third-party vendors. 1FINITY: A Revolutionary, Disaggregated Platform For network operators seeking an open, simple, scalable architecture to meet escalating bandwidth demand, Fujitsu provides 1FINITY, a revolutionary disaggregated platform that delivers unprecedented flexibility, scalability, and efficiency. Unlike the traditional converged systems other vendors provide, the programmable, blade-centric design of 1FINITY offers operators a pay-as-you grow approach with low initial investment. Additional benefits include high rack space utilization, evergreen technology design, operational convergence, open pluggable optics, open APIs, and open protocols. us.fujitsu.com/telecom Data Sheet Fujitsu 1FINITY S100 Switch Efficient 1 GbE or 10 GbE to 100 GbE Aggregation Layer 2 Switching The 1FINITY S100 Switch is a modular Ethernet switching platform ideal for networks that require 1 GbE or 10 GbE to 100 GbE aggregation for Carrier Ethernet 2.0–compliant E-Line services. The 1RU blade provides 1.2 Tbps bidirectional switching with four Plug-In Units (PIUs). The S100 blade supports 12 × SFP+ 10 GbE/OTU2, 3 × CPF4 100 GbE, 12 × SFP+ 1 GbE/10 GbE, or 1 × 100G NBO CFP2-ACO*. The S100 simplifies operation with ITU-T Y.1731 for performance monitoring, ITU-T G.8031, and G.8032 for sub-50 millisecond Ethernet linear and ring protection switching, in addition to link aggregation for facility protection. with the FLASHWAVE 9500 and the 1FINITY T200 blade. For dense metro DCI applications requiring up to 200G per lambda transport, the S100 can be deployed with the 1FINITY T100 blade. Simplified Network Operations The 1FINITY S100 blade has a Linux-based operating system and can be managed with a Web-based GUI, CLI scripts, or the NETCONF API. The GUI or CLI script can provision various service options. The NETCONF management API makes it easy to use the 1FINITY S100 with SDN network controllers, including Fujitsu Virtuora® Network Controller (NC). × Metro to Long-Haul Applications The scalable blade architecture of the 1FINITY S100 can be used with existing FLASHWAVE® 9500 and FLASHWAVE CDS deployments and with the 1FINITY Transport blade family. The combination of an S100 and a DWDM optical transport device like the FLASHWAVE 9500 can efficiently transport 10 GbE and 100 GbE services on 100G optical lambdas. For long-haul transport up to 200G per lambda, the S100 can be teamed Up to 3 × CFP4 100 GbE ports Page 2 of 4 Up to 12 × SFP+ 10 GbE/OTU2 ports Up to 12 × SFP+ 1 GbE/10GbE ports Up to 1 × CFP2-ACO 100 GbE DWDM port us.fujitsu.com/telecom Data Sheet Fujitsu 1FINITY S100 Switch Technical Specifications Base System Hardware Physical Characteristics System Configuration Modular 1RU blade PIU/FRU per Blade 4 Local Management Port (LMP) None Dimensions H×W×D 1.75 × 19 × 17.72” (44.45 × 483 × 450 mm) W = 19” or 23” with mounting rails D<600 mm with fiber management Rack Compatibility 19 and 23” Weight S100 blade: 7.58 kg (16.711 lbs) 12 × SFP+ PIU: 0.609 kg (1.343 lbs) 3 × CFP4 PIU: 0.603 kg (1.329 lbs) Fan: 0.380 kg (0.838 lb) Management Port (LCN) 2 × Gigabit Ethernet SFP (T, SX, LX, EX, ZX) Front LEDs System Status, Severity, Port Fan Hot swappable fan unit 3 fans, alarm monitored Operating Environment Power Supply Dual fixed DC power supplies Operating Temperature 5 to +40 °C Software OS Linux Short Term Temperature –5 to +50 °C Humidity, Normal Operating 5 to 85% noncondensing Humidity, Short Term 5 to 93% noncondensing Service Ports Service Ports per Blade/PIU Optical/Electrical Interface Supported Interfaces 10 GbE/ OTU2 100 GbE 100 GbE DWDM* 1 GbE/ 10 GbE 12 × 10 GbE/OTU2 per PIU 3× 100 GbE per PIU 1× 100 GbE DWDM per PIU 12 × 1 GbE/ 10 GbE per PIU SFP+ CFP4 CFP2-ACO SFP/SFP+ SR, ER, LR, ZR, DWDM SR4, LR4, ERL, ERL, ER4 TBD SX, LX, EX, ZX, SR, ER, LR, ZR, CWDM (Ethernet Only) Regulatory and Compliance Performance Monitoring Power Power Supply Dual fixed power supplies 120 V AC No –48 V DC –40 V DC to –57 V DC Power Consumption 700 W (typical) FCC FCC Part 15, Class A NEBS NEBS Level 3 UL/CSA UL/CSA 60950-1 CE CE ROHS ROHS Service PMs 24-hour, 15-minute, and 5-minute bins for PMs IEC/EN IEC/EN 60825-1, 60825-2 Thresholds and TCA Support (user assignable) WEEE WEEE • Frame delay • Delay variation • Loss ratio RCM RCM CDRH FDQ CDRH Ethernet SLA PMs (Y.1731) Ethernet Port PMs • Rx, Tx and error statistics • Input and output rate per port • Input and output utilization per port Management Virtuora NC Yes Web GUI Yes CLI Yes NETCONF/YANG Yes SNMP SNMPv2 NTP, SNTP, Telnet, and FTP Telnet, FTP and SFTP, NTP In-Band Management MVLAN OSMINE Support CLEI Page 3 of 4 us.fujitsu.com/telecom Data Sheet Fujitsu 1FINITY S100 Switch Technical Specifications Ethernet Switching Ethernet Services Switching Fabric 1.2 Tbps E-Line Yes Packets per Second 1.44 Gbps E-Line MEF CE 2.0 Yes* MAC Address Table • 750 K table entries • Enable/diable learning per port E-LAN Yes E-LAN MEF CE 2.0 Yes* Jumbo Frames 9608 bytes VLAN Tagging 802.1Q 4094 C-VLANs Provider Bridging 802.1ad 4094 S-VLANs Tagging • CVLAN translation • Double tagging • Tagging, de-tagging, swapping • Virtual untagged Traffic QoS Priority Queues 8 queues per port/4 queues per flow Traffic Classification • IEEE 802.1Q, Port, VLAN, ToS, DSCP • CIR/CBS and PIR/PBS • 2-rate, 3-color (2R3C) Bandwidth Meters • Bandwidth profiles • Ingress and egress filters • Per service in 1 Mbps increments Ethernet OAM Fault Management • IEEE 802.1Q, Port, VLAN, ToS, DSCP • CIR/CBS and PIR/PBS • 2-rate, 3-color (2R3C) Loopbacks • Station loopback • Loopback based on L2 and L3 filter • MAC address swap for RFC 2544 Topology Discovery LLDP Network Protection Ethernet Protection • <50 ms protection switching • 3.3 ms CCMs in hardware • Nonrevertive/revertive • ITU-T G.8031 • ITU-T G.8032 • Multiple instances/laddered rings Link Aggregation 0:N LAG N<=16 1+1 LAG** LAG over G.8032 MC-LAG** Security • L2 loop monitoring • L2 loop protocol • Filtering * Supported in R2.2 ** Supported in R2.3 Fujitsu Network Communications, Inc. 2801 Telecom Parkway, Richardson, TX 75082 Tel: 888.362.7763 us.fujitsu.com/telecom © Copyright 2017 Fujitsu Network Communications, Inc. FLASHWAVE® is a trademark of Fujitsu Network Communications, Inc. (USA). 1FINITY™, VIRTUORA ®, FUJITSU (and design)® and “shaping tomorrow with you” are trademarks of Fujitsu Limited in the United States and other countries. All Rights Reserved. All other trademarks are the property of their respective owners. Configuration requirements for certain uses are described in the product documentation. Features and specifications subject to change without notice. Page 4 of 4 3.0/R2.1/12.17 us.fujitsu.com/telecom
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Print high-res Create Date : 2017:12:19 15:41:01-06:00 Creator : Adobe InDesign CC 2017 (Windows) Modify Date : 2017:12:19 15:41:49-06:00 Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.158975, 2016/02/13-02:40:29 Instance ID : uuid:9ef13e8f-cf13-4986-b935-8e976113697d Original Document ID : adobe:docid:indd:5e25a8a7-80b8-11dd-a082-f1648f0ac1ea Document ID : xmp.id:9c793aaa-a8ce-5844-a734-fdd4f48c3d17 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:8bdd1e20-4458-d34b-8cec-e24899bd21ae Derived From Document ID : xmp.did:73b1e165-7f6b-44f1-93d0-e7cdf74ca740 Derived From Original Document ID: adobe:docid:indd:5e25a8a7-80b8-11dd-a082-f1648f0ac1ea Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:12:19 15:41:01-06:00 Metadata Date : 2017:12:19 15:41:49-06:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 4EXIF Metadata provided by EXIF.tools