Furuno USA 9ZWRTR101 Transceiver for Radar model FAR-1518/1528 User Manual

Furuno USA Inc Transceiver for Radar model FAR-1518/1528

Installation Manual Part 3

Download: Furuno USA 9ZWRTR101 Transceiver for Radar model FAR-1518/1528 User Manual
Mirror Download [FCC.gov]Furuno USA 9ZWRTR101 Transceiver for Radar model FAR-1518/1528 User Manual
Document ID2768692
Application IDE061SBxccVRjzwJtWHMtpA==
Document DescriptionInstallation Manual Part 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize223.42kB (2792808 bits)
Date Submitted2015-09-30 00:00:00
Date Available2016-03-28 00:00:00
Creation Date2015-09-14 17:34:22
Producing SoftwareAcrobat Distiller 10.1.14 (Windows)
Document Lastmod2015-09-14 17:52:19
Document Titleuntitled
Document CreatorFrameMaker 11.0.2

2. WIRING
2.4
Processor Unit
The illustration below is the AC specification unit. The DC specification unit does not
have the fuse.
Power cable
DC power: DPYC-6
AC power: DPYC-2.5
TTYCSLA, antenna, control
unit and RW-4864 cables
(For clamping positions,
see the sticker on the
reverse side of the cover.)
* For the antenna cable of
the FAR-15x8, remove the
spacer to insert the cable.
RGB cable (option)
(to external monitor)
Ground terminal
(Use IV-8sq.,
SD card
local supply)
slot
USB connector
( No use.)
2.4.1
DVI-D cable
(5 m, to Monitor Unit)
LAN cable (UTP, CAT5e, local supply)
(to other radar or HUB switch)
(Fasten the cable to the post below
the connector with a cable tie.)
How to fabricate the power cable
1. Remove the armor of the cable by the amount shown in the figure below.
2. Remove the insulation of the cores 10 mm.
3. Fix crimp-on lugs (FV5.5-4, yellow, supplied) to the cores. Cover the end of the
armor with vinyl tape. Lay the cable in the cable clamp on the cable entry side of
the processor unit. Fasten the cable clamp.
4. Fasten the crimp-on lugs to the terminal block, referring to the interconnection diagram at the back of this manual.
DC: 60 mm
AC: 50 mm
DC power: DPYC-6
AC power: DPYC-2.5
Armor
10
Taping
2-11
2. WIRING
2.4.2
How to fabricate signal cable, cables from external equipment
Signal cable for FAR-1518, FAR-1528
Vinyl sheath
10
Armor
300
50
Inner sheath
Coaxial
cable
Expose the cables
then twist shield.
Fold back shield.
Core
Attach the crimp-on lug to the core.
Signal cable for FAR-1513, FAR-1523
Expose cores, then wind
shield around the armor.
Coaxial Fold back
cable
shield.
Coaxial cable
Armor
14
Vinyl tape
Set this part in the cable clamp.
How to fasten the coaxial cable
Fasten shield with clamp.
NOTICE
Do not use crimp-on lug, to
prevent contact resistance
from increasing.
Fasten conductor with screw.
2-12
Conductor
2. WIRING
TTYCS, TTYCSLA cables (for external equipment)
For lengths, see the table on the next page.
How to fabricate the TTYCS series cable
L1
Armor
Shield
L2
Vinyl tape
Secure tape with cable
tie (supplied).
Expose cores, then wind
shield around the armor.
Set this part in cable clamp.
How to fabricate the TTYCSLA series cable
L1
Armor
L2
Sheath
Drain wire
Vinyl tape
Secure tape with cable
tie (supplied).
Set this part in cable clamp.
Crimp-on lug
Pass the heat-resistant tubing (supplied) onto the
drain wire. Attach a crimp-on lug (preattached to the
processor unit) to the drain wire. Fasten the
crimp-on lug to its original location.
How to connect wires to WAGO connector
Press downward.
Terminal
opener
WAGO connector
Wire

1. Twist the cores.
2. Press the terminal opener downward.
3. Insert the wire into the hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
Twist
2-13
2. WIRING
Connector, cable and lengths (L1, L2 and L3)
Connector No.
J613 (Ext. alarm contact signal)
J614 (HDG)
J615 (AIS)
J616 (GPS), J617 (LOG)
J618/J619/J620 (AMS/ECDIS/AD-10)
Cable type
TTYCSLA-7
TTYCSLA-1Q
TTYCSLA-4
TTYCSLA-1
TTYCSLA-4
L1
300
250
200
200
200
L2
70
70
70
70
70
L3
150
150
200
200
200
Signal cable RW-4864 (for sub display connection)
To use the equipment as the main radar and connect a sub-radar, connect to J612
(SUB DISPLAY 1) or J611 (SUB DISPLAY 2), using the optional signal cable RW4864. A maximum of two sub-radars can be connected.
2-14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2015:09:14 17:34:22+09:00
Creator                         : FrameMaker 11.0.2
Modify Date                     : 2015:09:14 17:52:19+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2015:09:14 17:52:19+09:00
Creator Tool                    : FrameMaker 11.0.2
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:2bbb3cc1-5199-482e-be66-f037552a6b94
Instance ID                     : uuid:77a61b95-8e02-4c7d-8cea-8f664c50fe11
Producer                        : Acrobat Distiller 10.1.14 (Windows)
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ADB9ZWRTR101

Navigation menu