Furuno USA 9ZWRTR104 Transceiver for Radar Sensor DRS4DL User Manual

Furuno USA Inc Transceiver for Radar Sensor DRS4DL

User Manual I

Download: Furuno USA 9ZWRTR104 Transceiver for Radar Sensor DRS4DL User Manual
Mirror Download [FCC.gov]Furuno USA 9ZWRTR104 Transceiver for Radar Sensor DRS4DL User Manual
Document ID2522484
Application ID+5wGu6abXSFz8axSwnphtw==
Document DescriptionUser Manual I
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize124.67kB (1558428 bits)
Date Submitted2015-02-03 00:00:00
Date Available2015-02-11 00:00:00
Creation Date2015-01-28 11:24:38
Producing SoftwareAcrobat Distiller 10.1.10 (Windows)
Document Lastmod2015-01-30 17:51:19
Document Titleuntitled
Document CreatorFrameMaker 11.0

Installation Manual
RADAR SENSOR
MODEL DRS4DL
SAFETY INFORMATION.................................................................................................. i
SYSTEM CONFIGURATION .......................................................................................... iii
EQUIPMENT LIST .......................................................................................................... iv
1. INSTALLATION.......................................................................................................... 1
1.1 Installation Considerations....................................................................................................1
1.2 Installation of the Radar Sensor............................................................................................2
2. WIRING....................................................................................................................... 6
2.1 Power Requirement ..............................................................................................................6
2.2 Check Points After Installation ..............................................................................................6
3. MAINTENANCE, TROUBLE- SHOOTING................................................................. 8
3.1
3.2
3.3
3.4
Maintenance .........................................................................................................................8
Replacement of Fuse............................................................................................................8
Troubleshooting ....................................................................................................................9
Replacement of Magnetron...................................................................................................9
PACKING LIST ............................................................................................................ A-1
OUTLINE DRAWING ................................................................................................... D-1
INTERCONNECTION DIAGRAM ................................................................................ S-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
All rights reserved.
Printed in Japan
A :
0000
Z1 : JAN . 30, 2015
Pub. No. IME-36370-Z1
(TASU )
DRS4DL
0 0 0 1 6 5 8 2 8 1 0
SAFETY INFORMATION
Read these safety instructions before installing or operating the equipment.
WARNING
Indicates a potentially hazardous situation
which, if not avoided, can result in serious
injury or death.
CAUTION
Indicates a potentially hazardous situation
which, if not avoided, can result in minor or
moderate injury.
Warning, Caution
Prohibitive Action
Mandatory Action
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
The installation does not require you to open the radar sensor.
Do not disassemble or modify the equipment.
Fire, electrical shock or serious injury can result.
Wear a safety belt and hard hat when working on the antenna unit.
Serious injury or death can result if someone falls from the radar mast.
Be sure the power source is compatible with the voltage rating of
the equipment.
Connection of an incorrect power source can cause fire or damage the
equipment.
Turn off the power at the power source before beginning the
installation.
Fire, electrical shock or serious injury can result if the power is left on
or is applied while the equipment is being installed.
Use the proper fuse.
Use of a wrong fuse can damage the equipment or cause fire.
Do not depend one navigation device for the navigation of
the vessel.
For the safety of vessel and crew, the navigator must check all
aids available to confirm position.
SAFETY INFORMATION
WARNING
The radar antenna emits electromagnetic radio frequency (RF)
energy which can be harmful, particularly to your eyes. Never
look directly into the antenna aperture from a close distance
while the radar is in operation or expose yourself to the
transmitting antenna at a close distance.
Distances at which RF radiation levels of 100, 50 and 10 W/m2 exist
are given in the table below.
100 W/m2
50 W/m2
10 W/m2
N/A
N/A
1.1 m
NOTICE
Observe the following compass safe distance to prevent
interference to a magnetic compass.
Standard compass Steering compass
0.95 m
1.55 m
It is recommended that you connect the sensor to a disconnecting
device (circuit breaker, etc.) to control the power.
WARNING LABEL
A warning label is attached to the sensor. Do not remove the label.
If the label is missing or damaged, contact a FURUNO agent or dealer about
replacement.
Name: Warning Label (2)
Type: 03-129-1001-3
Code No: 100-236-743
ii
SYSTEM CONFIGURATION
RADAR SENSOR
DRS4DL
Pre-attached
power/LAN cable 1 m
Selectable power/LAN cable
CP03-36400/
CP03-36410/
CP03-36420/
CP03-36430
(10/15/20/30 m)
LAN
: Standard Supply
Power supply
12/24 VDC
Multi Function Display
TZTL12F/TZTL15F
* TZT9/TZT14/TZTBB
iii
* Software upgrade is required.
EQUIPMENT LIST
Standard supply
Name
Type
Code No.
Qty
Remarks
Radar Sensor
RSB-127-104
000-027-200-00
Installation Materials
CP03-35701
001-265-920-00
CP03-36400
000-027-211-00
Power/LAN cable 10 m
CP03-36410
000-027-212-00
Power/LAN cable 15 m
CP03-36420
000-027-213-00
Power/LAN cable 20 m
CP03-36430
000-027-214-00
Power/LAN cable 30 m
Spare Parts
SP03-17901
001-351-470-00
Documents
IME-36370-*
000-165-828-10
MDC-36370-*
000-165-829-10
E32-01314-*
000-178-948-10
Optional supply
Name
Type
Radome Mount
OP03-209
Code No.
Qty
001-078-350-00
iv
Remarks
1.
INSTALLATION
1.1
Installation Considerations
General considerations
NOTICE
Do not apply paint, anti-corrosive sealant or contact
spray to coating or plastic parts of the equipment.
Those items contain organic solvents that can damage
coating and plastic parts, especially plastic connectors.
• The radar sensor has no power switch. Therefore, it is recommended that you connect the sensor to a distribution switchboard with a switch for power control.
Sensor placement
• Install the radar sensor on the hardtop, radar arch or on a mast on an appropriate
platform. (For sailboats, a “radome mount” is optionally available for fixing the sensor to a mast.) Place the sensor where there is a good all-round view with, as far as
possible, no part of the ship’s superstructure or rigging intercepting the scanning
beam. Any obstruction will cause shadow and blind sectors. A mast for instance,
with a diameter considerably less than the horizontal beam width of the radiator, will
cause only a small blind sector, but a horizontal spreader or cross trees in the same
horizontal plane as the radar sensor would be a much more serious obstruction; you
would need to place the radar sensor well above or below it. Be sure there are no
metallic objects near the antenna. See illustrations below for typical placement on
a sailboat and powerboat.
Horizontal Beam Width
12.5°
12.5°
(Rear View)
(Rear View)
Rear View
Radar sensor
Radar sensor
Installation on a sailboat
Installation on a powerboat
Typical installation on a sailboat and power boat
1. INSTALLATION
• It is rarely possible to place the radar sensor where a completely clear view in all
directions is available. Thus, you should determine the angular width and relative
bearing of any shadow sectors for their influence on the radar at the first opportunity
after fitting.
• In order to reduce the chance of picking up electrical interference, avoid where possible routing the power cable near other electrical equipment on-board. Also, avoid
running the cable in parallel with other power cables.
• Select a location that does not allow water to accumulate at the base of the sensor.
• A magnetic compass will be affected if the radar sensor is too close to the compass.
Observe the compass safe distances mentioned in the SAFETY INSTRUCTIONS
to prevent interference to a magnetic compass.
• Do not paint the radome to ensure proper emission of the radar waves.
• When this radar sensor is to be installed on large vessels, consider the following
points:
• The length of the standard supply power/LAN cable 1 m (from radome to the connector).
• The power/LAN cable runs between the radar sensor and display and comes in
lengths of 10 m, 15 m, 20 m or 30 m. Select the length when purchasing.
• Deposits and fumes from a funnel or other exhaust vent can adversely affect the
aerial performance and hot gases may distort the radiator portion. The radar sensor must not be mounted where the temperature is more than 55°C (131°F).
1.2
Installation of the Radar Sensor
Prepare a wrench for M10 bolts for installation. Determine the suitability of the mounting location BEFORE permanently mounting the sensor. Incoming and outgoing signals may overlap one another depending on the shape of the vessel, preventing
communication between the radar and display. Set the sensor on the selected location
and connect the sensor to the distribution switchboard and display unit. Turn on the
sensor and the display unit. Check that the picture is updated with each sweep on the
display unit. Some trial and error may be necessary to find a suitable location.
Required tools for installation
Prepare below tool before installation of radar sensor.
• A wrench for M10 bolts
• A drill with 11 mm (0.43”) drill bit
1. INSTALLATION
Installation on a platform
Installation of radar sensor to a platform is as shown below. Read below for the steps
and details.
STERN
BOW
Align bow mark (Δ) on
radome with ship’s bow.
Power/LAN cable (1 m)
Platform
Flat washer
Spring washer
Hex bolt (M10×20)
Drill holes referring to the outline drawing
and the mounting template
1. Remove four each of hex bolts (M1020), flat washers and spring washers preattached to the bottom of the radar sensor.
Flat washer
Spring washer
Hex bolt (M10×20)
×4
2. Construct a platform, cut four holes in the platform referring to the outline drawing
and the mounting template at the back of this manual. Fasten the platform to the
mounting location. The holes of the platform must be parallel with the fore and aft
line.
3. Put the radar sensor on the platform with the bow mark () on the sensor aligned
with the ship’s bow.
4. Use hex bolts*, flat washers and spring washers (removed at the first step) to attach the radar sensor to the platform. The torque for the bolts is 19.6 to 24.5 N•m.
Apply marine sealant to the bolts.
Sensor base
Determine the length of bolts
according to platform thickness.
Flat washer
Platform
Spring washer
Hex bolt
1. INSTALLATION
*See the table below to determine the bolt length.
Platform thickness and bolt to use
Platform thickness
5 mm or less
6 - 10 mm
Over 10 mm
Size of bolts to use
M1020 (Supplied, prefastened to radome.)
M1025 (Supplied as spare parts)
Supply locally.
5. Connect the power/LAN cable pre-attached to the radar sensor with a power/LAN
cable. The connector pin assignment is as below.
17 mm
Connector pin assignment
Observe below guidelines for laying the power/LAN cable.
Guidelines for laying the power/LAN cable
• The connectors must not strike any part of the vessel by wind, etc.
• The load applied to the connectors must not be more than the power/LAN cable.
• If the cable is passed through a mast on a sailboat, be sure the cable does not
touch ropes (sheet, halyard, etc.).
• Do not fasten the cable to the hull.
• The cable must be fixed so no tension is applied to the connectors. To prevent
tension, create a loop in the cable close to the sensor and tie the loop with cable
ties, as in the figure below.
Loop cable and tie loop with cable ties.
The minimum bend diameter is 80 mm.
• Wrap the junction of the connectors with self-vulcanizing tape for waterproofing.
• Fasten the cable to the mast, etc. at the neck of each connector with a cable tie.
6. Connect the power/LAN cable to the power source and display unit.
1. INSTALLATION
Installation with the radome mount
The optional radome mount lets you fasten the radar sensor to a mast on a sailboat.
Name, Type: Radome Mount, OP03-209
Code No.: 001-078-350
Name
Type
Code No.
Qty
Mounting plate
03-018-9001-0
100-206-740-10
Support plate (1)
03-018-9005-0
100-206-780-10
Support plate (2)
03-018-9006-0
100-206-790-10
Bracket (1)
03-028-9101-1
100-206-811-10
Bracket (2)
03-028-9101-2
100-206-812-10
Fixing plate
03-028-9103-1
100-206-831-10
Hex bolt w/washer
M820 SUS304
000-162-955-10
Hex bolt w/washer
M412 SUS304
000-162-956-10
How to assemble the bracket
1. Fasten the fixing plates to brackets (1) and (2) with four M820 hex bolts.
2. Fit brackets (1) and (2) loosely with support plates (1) and (2) using four M412
hex bolts, so that the gap between the brackets can be adjusted.
3. Place the mounting plate on the bracket and fix it loosely with four M820 hex
bolts.
How to fasten the bracket to the mast
1. Drill eight holes of 6.5 mm diameter in the mast and fix the bracket with eight stainless steel rivets (local supply) of 6.4 mm diameter.
2. Tighten the bolts on the bracket.
3. Fasten the radar sensor to the bracket.
Connect the power cable to the power source, observing the guidelines for laying the
power cable shown on this page.
ASSEMBLED RADOME MOUNT
M8×20
Mounting plate
Fixing plate
M8×20
Bracket (1)
Rivet
Support plate (2)
Support plate (1)
M8×20
Bracket (2)
M4×12
How to assemble the radome mount
M10×25
How to fasten the sensor to the radome mount
2.
WIRING
2.1
Power Requirement
The DRS4DL requires either 12 VDC or 24 VDC power. The 10/15/20 m cables are
for 12 or 24 VDC, and the 30 m cable is for 24 VDC only. Connect the red cable to the
positive terminal of ship’s battery; the blue cable to the negative terminal. A black cable is a shielding cable for grounding.
2.2
Check Points After Installation
Before using the product, carry out the following:
• Mechanical checks
• Turning the power on and initial setup
Mechanical checks
Check below points before switching on the DRS4DL.
• All washers are in place and bolts are fully tightened.
• All connections are secure.
• All connecting cables and wires are secured.
• If the cable is exposed to the weather, wrap the connection point with self-vulcanizing tape.
Connect cables
Secure connection with self-vulcanizing tape
2. WIRING
Turning the power on and initial setup
WARNING
The radar antenna emits electromagnetic radio frequency (RF)
energy, which can be harmful to the
human body and interfere with pacemaker function. Never look directly
into the antenna aperture and keep
at least 1.1 m away from the radar
antenna while the radar is in operation.
Use the information in this manual and the manual for TZTL12F/TZTL15F/TZT9/
TZT14/TZTBB* to power the sensor and to proceed with initial setup.
* Hereafter these units are referred to as “multifunction display device”.
1. Press and hold down the power key of your multifunction display device until the
unit is ON. The magnetron warm-up sequences start. When the warm-up sequence is completed, the unit goes into the standby mode.
2. Take the appropriate action on your multifunction display device to turn on the
DRS4DL.
3. If necessary, adjust the brightness and change the language on multifunction display device.
4. Ensure that all personnel are clear of antenna.
5. Check if the menu items on multifunction display device are correctly displayed.
6. Check if the heading is correctly aligned - targets should appear at their correct
bearing relative to the boat’s bow. Adjust the alignment if necessary, referring to
installation manual of your multifunction display device.
7. Check the display timing, referring to installation manual of your multifunction display device.
3.
MAINTENANCE, TROUBLESHOOTING
WARNING
DO NOT OPEN THE SENSOR.
Electrical shock hazard
There are no user-serviceable parts
inside. Only qualified personnel are
allowed to work inside the equipment.
3.1
Maintenance
Regular maintenance is important for good performance. Check the points mentioned
below every 3 to 6 months to keep the radar sensor in good working order. Observe
the safety instructions at the front of this manual when working on the mast.
Check point
Fixing bolts
• Corrosion
• If they are tightly fastened
Radome
• Cracks
• Foreign materials
3.2
Action
• Replace corroded bolts.
• Tighten loosened bolts.
• Coat new bolts with marine sealant.
If a crack is found, repair it temporarily with a small
amount of sealing compound or adhesive. Bring the unit
to your dealer for permanent repairs.
Foreign materials on the radome can cause a considerable drop in sensitivity. Remove foreign materials with a
freshwater-moistened cloth. Do not use commercial
cleaners to clean the sensor; they can remove paint and
markings or deform the plastic.
Replacement of Fuse
The 5A fuse (Type: EFS0001-0001009, Code No.: 000-168-869-10) in the fuse holder
on the power/LAN cable protects the radar sensor from over current and equipment
fault. If you cannot turn on the power, check the fuse to see if it has blown. If the fuse
has blown, find the reason before you replace the fuse. If the fuse blows again after
the replacement, contact your dealer for advice.
WARNING
Use the proper fuse.
Use of the wrong fuse can damage the equipment or cause fire.
3. MAINTENANCE, TROUBLE- SHOOTING
3.3
Troubleshooting
The table below provides simple troubleshooting procedures to restore normal operation. If you cannot restore normal operation, contact your dealer for advice.
Trouble
The power cannot be turned on.
Remedy
• Check if the power/LAN cable is connected to
the power source and the power source is on.
• Check the power cable for damage.
• Check if the fuse has blown.
• Check antenna cable.
• If the picture freezes, reboot the display unit.
Check that the antenna cable is fastened.
Picture is not updated or the picture
freezes.
Marks and characters appear on
the display, but echoes do not appear.
You changed the range, but the ra- • Try to zoom in or out the radar display.
dar picture does not change.
• Turn the power off and on.
Used for long time and the signal
Have a technician check the magnetron.
strength is low.
3.4
Replacement of Magnetron
The life expectancy of the magnetron is approx. 5,000 hours (including standby). The
effectiveness of the magnetron decreases over time, causing lower-than-normal signal strength and loss of echoes. If you feel the signal strength is low, contact your dealer about replacement of the magnetron.
Name
Magnetron
Type
80-0691
Code No.
001-266-460-00
FURUNO
DRS4DL
SPECIFICATIONS OF RADAR SENSOR
DRS4DL
1.1
1.2
1.3
1.4
1.5
1.6
RADIATOR
Antenna type
Antenna length
Horizontal beam width
Vertical beam width
Sidelobe attenuation
Rotation
Patch array antenna
18-inch
5.2° typical (3 dB)
25° (3 dB)
-20 dB (within ±20°), -25 dB (±20° or more)
24 rpm
2.1
2.2
2.3
2.4
2.5
RADAR FUNCTION
Tx frequency
9410±30 MHz, P0N
Output power
4 kW
Duplexer
Ferrite circulator
Intermediate frequency 60 MHz
Range, Pulse length and Pulse repetition rate
Range (NM) Pulse length (s) PRR (Hz approx.)
0.125 to 0.5
0.08
360
0.75 to 2
0.3
360
3 to 24
0.8
360
2.6 Minimum range
25 m
2.7 Range resolution
25 m
2.8 Range accuracy
1 % of range in use or 0.01 NM, which is the greater
2.9 Bearing resolution
5.2°
2.10 Bearing accuracy
±1°
2.11 Warming up time
90 s
INTERFACE
LAN
1 port, Ethernet 100Base-T, RJ45
POWER SUPPLY
12-24 VDC: 2.1-1.0 A
5.1
5.2
5.3
5.4
ENVIRONMENTAL CONDITIONS
Ambient temperature
-25°C to +55°C (storage: +70°C or less)
Relative humidity
95% or less at +40°C
Degree of protection
IP26
Vibration
IEC 60945 Ed.4
UNIT COLOR
N9.5 (cover), 2.5PB3.5/10 (bottom)
SP - 1
E3637S01A
141210
PACKING
LIST
03HP-X-9851 -0
1/1
DRS4DL
N A M E
ユニット
O U T L I N E
DESCRIPTION/CODE №
Q'TY
UNIT
レーダーセンサー
RSB-127-104
RADAR SENSOR
000-027-200-00
予備品
SPARE PARTS
予備品
SP03-17901
SPARE PARTS
001-351-470-00
工事材料
INSTALLATION MATERIALS
工事材料
CP03-35701
INSTALLATION MATERIALS
001-351-480-00
図書
DOCUMENT
型紙
TEMPLATE
E32-01314-*
000-178-948-1*
**
装備要領書(英)
INSTALLATION MANUAL (EN)
IME-36370-*
000-165-828-1*
**
コ-ド番号末尾の[**]は、選択品の代表コードを表します。
CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL.
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
03HP-X-9851
FURUNO Worldwide Warranty for Pleasure Boats (Except North America)
This warranty is valid for products manufactured by Furuno
Electric Co. (hereafter FURUNO) and installed on a pleasure
boat. Any web based purchases that are imported into other
countries by anyone other than a FURUNO certified dealer may
not comply with local standards. FURUNO strongly recommends
against importing these products from international websites as
the imported product may not work correctly and may interfere
with other electronic devices. The imported product may also be
in breach of the local laws and mandated technical requirements.
Products imported into other countries as described previously
shall not be eligible for local warranty service.
For products purchased outside of your country please contact
the national distributor of Furuno products in the country where
purchased.
This warranty is in addition to the customer´s statutory legal
rights.
Warranty repairs carried out by companies/persons other than a
FURUNO national distributor or a certified dealer is not covered
by this warranty.
6. Warranty Limitations
When a claim is made, FURUNO has a right to choose whether
to repair the product or replace it.
The FURUNO warranty is only valid if the product was correctly
installed and used. Therefore, it is necessary for the customer to
comply with the instructions in the handbook. Problems which
result from not complying with the instruction manual are not
covered by the warranty.
FURUNO is not liable for any damage caused to the vessel by
using a FURUNO product.
The following are excluded from this warranty:
1. Terms and Conditions of Warranty
FURUNO guarantees that each new FURUNO product is the
result of quality materials and workmanship. The warranty is
valid for a period of 2 years (24 months) from the date of the
invoice, or the date of commissioning of the product by the
installing certified dealer.
a.
Second-hand product
b.
Underwater unit such as transducer and hull unit
c.
Routine maintenance, alignment and calibration
services.
d.
Replacement of consumable parts such as fuses,
lamps, recording papers, drive belts, cables, protective
covers and batteries.
e.
Magnetron and MIC with more than 1000 transmitting
hours or older than 12 months, whichever comes first.
f.
Costs associated with the replacement of a transducer
(e.g. Crane, docking or diver etc.).
g.
Sea trial, test and evaluation or other demonstrations.
h.
Products repaired or altered by anyone other than the
FURUNO national distributor or an authorized dealer.
i.
Products on which the serial number is altered,
defaced or removed.
j.
Problems resulting from an accident, negligence,
misuse, improper installation, vandalism or water
penetration.
k.
Damage resulting from a force majeure or other natural
catastrophe or calamity.
l.
Damage from shipping or transit.
m.
Software updates, except when deemed necessary
and warrantable by FURUNO.
n.
Overtime, extra labour outside of normal hours such as
weekend/holiday, and travel costs above the 160 KM
allowance
o.
Operator familiarization and orientation.
2. FURUNO Standard Warranty
The FURUNO standard warranty covers spare parts and labour
costs associated with a warranty claim, provided that the product
is returned to a FURUNO national distributor by prepaid carrier.
The FURUNO standard warranty includes:
Repair at a FURUNO national distributor
All spare parts for the repair
Cost for economical shipment to customer
3. FURUNO Onboard Warranty
If the product was installed/commissioned and registered by a
certified FURUNO dealer, the customer has the right to the
onboard warranty.
The FURUNO onboard warranty includes
•
•
•
•
Free shipping of the necessary parts
Labour: Normal working hours only
Travel time: Up to a maximum of two (2) hours
Travel distance: Up to a maximum of one hundred
and sixty (160) KM by car for the complete journey
4. Warranty Registration
For the Standard Warranty - presentation of product with serial
number (8 digits serial number, 1234-5678) is sufficient.
Otherwise, the invoice with serial number, name and stamp of
the dealer and date of purchase is shown.
For the Onboard Warranty your FURUNO certified dealer will
take care of all registrations.
5. Warranty Claims
For the Standard Warranty - simply send the defective product
together with the invoice to a FURUNO national distributor.
For the Onboard Warranty – contact a FURUNO national
distributor or a certified dealer. Give the product´s serial number
and describe the problem as accurately as possible.
FURUNO Electric Company, March 1, 2011
FURUNO Warranty for North America
FURUNO U.S.A., Limited Warranty provides a twenty-four (24) months LABOR and twenty-four (24) months PARTS
warranty on products from the date of installation or purchase by the original owner. Products or components that are
represented as being waterproof are guaranteed to be waterproof only for, and within the limits, of the warranty
period stated above. The warranty start date may not exceed eighteen (18) months from the original date of purchase
by dealer from Furuno USA and applies to new equipment installed and operated in accordance with Furuno USA’s
published instructions.
Magnetrons and Microwave devices will be warranted for a period of 12 months from date of original equipment
installation.
Furuno U.S.A., Inc. warrants each new product to be of sound material and workmanship and through its authorized
dealer will exchange any parts proven to be defective in material or workmanship under normal use at no charge for a
period of 24 months from the date of installation or purchase.
Furuno U.S.A., Inc., through an authorized Furuno dealer will provide labor at no cost to replace defective parts,
exclusive of routine maintenance or normal adjustments, for a period of 24 months from installation date provided the
work is done by Furuno U.S.A., Inc. or an AUTHORIZED Furuno dealer during normal shop hours and within a radius
of 50 miles of the shop location.
A suitable proof of purchase showing date of purchase, or installation certification must be available to Furuno U.S.A.,
Inc., or its authorized dealer at the time of request for warranty service.
This warranty is valid for installation of products manufactured by Furuno Electric Co. (hereafter FURUNO). Any
purchases from brick and mortar or web-based resellers that are imported into other countries by anyone other than a
FURUNO certified dealer, agent or subsidiary may not comply with local standards. FURUNO strongly recommends
against importing these products from international websites or other resellers, as the imported product may not work
correctly and may interfere with other electronic devices. The imported product may also be in breach of the local
laws and mandated technical requirements. Products imported into other countries, as described previously, shall not
be eligible for local warranty service.
For products purchased outside of your country please contact the national distributor of Furuno products in the
country where purchased.
WARRANTY REGISTRATION AND INFORMATION
To register your product for warranty, as well as see the complete warranty guidelines and limitations, please visit
www.furunousa.com and click on “Support”. In order to expedite repairs, warranty service on Furuno equipment is
provided through its authorized dealer network. If this is not possible or practical, please contact Furuno U.S.A., Inc.
to arrange warranty service.
FURUNO U.S.A., INC.
Attention: Service Coordinator
4400 N.W. Pacific Rim Boulevard
Camas, WA 98607-9408
Telephone: (360) 834-9300
FAX: (360) 834-9400
Furuno U.S.A., Inc. is proud to supply you with the highest quality in Marine Electronics. We know you had several
choices when making your selection of equipment, and from everyone at Furuno we thank you. Furuno takes great
pride in customer service.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2015:01:28 11:24:38Z
Creator                         : FrameMaker 11.0
Modify Date                     : 2015:01:30 17:51:19+09:00
Has XFA                         : No
Language                        : en
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : FrameMaker 11.0
Metadata Date                   : 2015:01:30 17:51:19+09:00
Producer                        : Acrobat Distiller 10.1.10 (Windows)
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:38b6d086-61cf-486a-a4e4-84d06211eddd
Instance ID                     : uuid:34e463fe-394d-4a20-8497-986e7a1448a4
Page Mode                       : UseOutlines
Page Count                      : 21
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ADB9ZWRTR104

Navigation menu