G4S Technology S843 Mifare proximity reader for access control User Manual
G4S Technology Limited Mifare proximity reader for access control Users Manual
Users Manual
Installation and User Instructions for S843 Readers
You should find that the
backplate has holes for
connection to most
standard electrical
backboxes.
With the backplate off (see above), mount
the backplate adjacent to the opening edge
of the door and at a convenient height.
Feed the required cables through the
backplate:
The cable from the controller.
The cable from the heater, if used (must
be a separate cable).
A cable from a Remote Interface Module
(RIM), if used. A RIM can reduce cable
lengths to door furniture.
!
!
!
2
The optional heater kit maintains the reader at
the correct temperature when mounted
outside. With the backplate off, remove the
backing paper from the two elements, then
stick them to the inner sides of the reader. The
heaters must be connected to a 24V AC supply
(min 25VA).
When mounting outside, the two-part gasket kit
must be fitted:
a) Remove the backplate from the reader
by releasing the two securing
screws.
b) Remove the cutouts and backing paper
from the two gaskets, then stick them to
the backplate as shown.
Outer gasket
Inner
gasket
Backplate
securing screws
Backplate
1Fit the Weatherproofing Kit
Mount the Backplate
The S843 is a
.
The
contactless smart-card reader, with
liquid-crystal display and keypad, able to read Philips
MIFARE and Philips MIFARE DESfire formatted
cards
S843 uses p
.
®
®
20mA current loop seudo-random
communications
0V
Connect shield at controller
end only (attach to case).
Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid
succession; there is no need to wait for UNLOCKED" to efore presenting another." disappear b
If the reader has been enabled for user-code mode at the controller, you can gain access by pressing
the # key, entering your card number, then pressing the * key.
RX+
RX-
TX+
TX-
12V S843 Reader
9600-0340. Installation and User Instructions for S843
Readers, Issue 1.0x2 7th October 2003. AMAG Technology
Ltd, 2003.
FCC Notice: This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
Any unauthorised modification to this device may void the
authority of the user to operate it.
©
Twisted pairs (use
Belden 9503 cable)
Controller
connections
(20mA current
loop)
The I/O terminal is
for connection to a
RIM (see the RIM
Instructions).
On completion, re-
secure the reader to
the backplate.
0V
TX+
- (not used)
TX-
I/0
RX+
RX-
+V
When UNLOCKED is displayed, the lock is released and you
may open the door.
UNLOCKED
If the ENTER PIN message is displayed, enter your PIN. If you
make a mistake, the message INCORRECT PIN is momentarily
displayed, followed by ENTER PIN, to prompt you to try again.
ENTER PIN
ACCESS DENIED
& LOCKED
These messages are displayed if you do not have access rights
to gain entry, or if the reader did not read your card properly (in
this case, present it again).
About the Reader Messages
These auxiliary indicators can be configured to operate in
conjunction with conditional commands.
Flashing or
steady
}
The reader is waiting for a valid card to be presented.
READY
Specifications
Input voltage: 9-14Vdc.
Input current (excl. heater): 150mA @ nom. 12Vdc.
Operating temperature: -4 to 158 F (-20 to 70 C)
without heater.
Operating humidity: 15 to 90%, non-condensing.
Maximum read range: 1" (25mm).
Approvals: EN50133, R&TTE, IP656.
°°
2
5Using the Reader
4Reader Connections
If you are using the reader with
a Hand Geometry Unit (HGU),
connect the HGU to PL1.
Ensure no jumpers are fitted across LK3 (NODE TERM), LK4 (HGU TERM) and LK2 (TEST). If a jumper
is provided, park it across one pin only. LK1 (USER FB) - set to 1 for sound on and 0 for sound off.
3Check the Reader Links