G4S Technology S870 S870 Proximity Card Reader User Manual Manual

G4S Technology Limited S870 Proximity Card Reader Manual

Manual

Mount  the  backplate  using  countersunk  headed  screws adjacent to the opening edge of the door.If fixing hole ’A’ is used then the breakout must be removed and the screw must not protrude.Feed the cable from the controller through the backplate.If the wall tamper function is to be used then the small hole in breakout  ‘B’  may  be  used  to  mark  the  position  of  the  wall screw before the breakout is removed.   An appropriate wall screw should then be adjusted in height to protrude through the hole to activate the tamper lever.The  front  cover  is  secured  to  the  backplate  by UNSCREWING the securing screw ‘C’ via the small hole in the enclosure so  that the  screw  head  locates  in  the counterbored hole on the inside of the enclosure.The screw should not be removed from the backplate.2Mount the BackplateThe S870reading HID  format card, with LED’s and keypad. The reader can be set to use Wiegand or For additional information regarding the installation, configuration and proper use of this product:SMS Software User Guide, P/N 9600-0429 Issue 7.0.4 or later, M2150 Design Guide, P/N 9600-0420 Issue Issue 1.6.4 or later. is a 125kHz proximity card reader that is capable of ®20mA current loop communications.Installation and User Instructions for S870-EX Keypad Readers1Fit The Weather Proofing KitWhen mounting outside, the gasket kit must be fitted:a) Remove the backplate from the reader after screwing the securing screw ‘C’ fully IN.b) Position the gasket between the back plate and the mounting surface.Note: For UL listed applications, use only manufacturer provided gasket, P/N 87X-GASKET. You should find that the backplate has holes for connection to most standard electrical backboxes.Note: (For UL Installations only)1). Consult local AHJ (Authority Having Jurisdiction) when installing access control readers and locking   mechanisms to any portal in an egress path.2). The use of Fail Closed / secure configuration shall be determined by local building codes and the local AHJ.3). Wiring methods shall be in accordance with NEC (National Electrical Code) ANSI/NFPA 70.4). All Interconnected devices must be UL listed.3Reader ConnectionsCAB
5Reader LinksPresent the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession;there is no need, for example, to wait for "GREEN LED’s" to disappear before presenting another.If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the O key, entering your card number, then pressing the P key.                               9600-0605. Installation and User Instructions for S870-EX  Keypad Readers, Issue 1.0x2  26th  June 2012.   G4S Technology, 2012. FCC  Notice:  This  device  complies  with  Part  15  of  the  FCC  Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)  this  device  must  accept  any interference received, including interference that may cause undesired operation.Any unauthorized modification to this device may void the authority of the user to operate it. All trademarks acknowledged.©LED Status IndicatorGREEN – The lock is released and you may open the door.RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again).YELLOW – Enter your PIN. If you make a mistake, the RED LED’s are momentarily displayed, followed by YELLOW LED’s, to prompt you to try again.SpecificationsInput voltage: 9-14Vdc. Input current:  120mA @ nom. 12Vdc.Operating temperature: -40 to 158°F (-40 to 70°C)Operating humidity: 15 to 90%, non-condensing.Maximum read range: 4" (100mm).Approvals: EN300330, EN3014896Using the ReaderSet SW1 switch2 (COM) to W for Wiegand communications, or C for 20mA current loop communications. Set SW1 switch1 (USER F/B - Keypad audio feedback) to 1 for sound on, or 0 for sound off. 4Reader Connections contd.0VRX+RX-TX+TX-12VController0VTX+TX-RX+RX-+VReaderTB120mA current loop0VGreenData 0RedData 112VController0VGRN0+VWiegandRED1ReaderTB1Connect shield at controller end only.Connect shield at controller end only.Note: Use SW1 switch2 to select the communications mode (See Step 5).Twisted pairs (use Belden 9503) cable or other UL Listed style 2464 (DUZX) cable.Multi conductor (Use Belden 9537) or other UL Listed style 2464 (DUZX) cable.

Navigation menu