G4S Technology S870 S870 Proximity Card Reader User Manual Manual

G4S Technology Limited S870 Proximity Card Reader Manual

Manual

Download: G4S Technology S870 S870 Proximity Card Reader User Manual Manual
Mirror Download [FCC.gov]G4S Technology S870 S870 Proximity Card Reader User Manual Manual
Document ID1739050
Application IDiZetXAbF9rNYkgMsoFsZsA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.41kB (267655 bits)
Date Submitted2012-07-09 00:00:00
Date Available2012-07-09 00:00:00
Creation Date2012-06-26 15:39:05
Producing SoftwareCorel PDF Engine Version 14.0.0.701
Document Lastmod2012-06-26 15:39:05
Document Title9600-0605 Issue 1.0x2- S870 Keypad Extreme Installation and User Instruction
Document CreatorCorelDRAW
Document Author: Watts;Andrew

Installation and User Instructions for S870-EX Keypad Readers
The S870 is a 125kHz proximity card reader that is capable of
®
reading HID format card, with LED’s and keypad. The reader can
be set to use Wiegand or 20mA current loop communications.
For additional information regarding the installation,
configuration and proper use of this product:
SMS Software User Guide, P/N 9600-0429 Issue 7.0.4 or later,
M2150 Design Guide, P/N 9600-0420 Issue Issue 1.6.4 or
later.
1 Fit The Weather Proofing Kit
When mounting outside, the gasket kit must be fitted:
a) Remove the backplate from the reader after screwing
the securing screw ‘C’ fully IN.
b) Position the gasket between the back plate and the
mounting surface.
Note: For UL listed applications, use only
manufacturer provided gasket, P/N 87X-GASKET.
Mount the Backplate
Mount the backplate using countersunk headed screws
adjacent to the opening edge of the door.
You should find
that the backplate
has holes for
connection to most
standard electrical
backboxes.
If fixing hole ’A’ is used then the breakout must be removed
and the screw must not protrude.
Feed the cable from the controller through the backplate.
If the wall tamper function is to be used then the small hole in
breakout ‘B’ may be used to mark the position of the wall
screw before the breakout is removed. An appropriate wall
screw should then be adjusted in height to protrude through
the hole to activate the tamper lever.
The front cover is secured to the backplate by
UNSCREWING the securing screw ‘C’ via the small hole
in the enclosure so that the screw head locates in the
counterbored hole on the inside of the enclosure.
The screw should not be removed from the backplate.
B A
Reader Connections
Note: (For UL Installations only)
1). Consult local AHJ (Authority Having Jurisdiction) when installing access control readers and locking
mechanisms to any portal in an egress path.
2). The use of Fail Closed / secure configuration shall be determined by local building codes and the
local AHJ.
3). Wiring methods shall be in accordance with NEC (National Electrical Code) ANSI/NFPA 70.
4). All Interconnected devices must be UL listed.
Reader Connections contd.
20mA current loop
Twisted pairs (use Belden
9503) cable or other UL
Listed style 2464 (DUZX)
cable.
Wiegand
Connect shield at
controller end
only.
0V
0V
TX+
TX-
RX+
RX-
RX+
RX-
TX+
TX12V
+V
Multi conductor (Use
Belden 9537) or other
UL Listed style 2464
(DUZX) cable.
0V
RED
GRN
0V
Red
Green
Data 0
Data 1
12V
+V
Controller
Reader
TB1
Connect shield
at controller end
only.
Reader
TB1
Controller
Note: Use SW1 switch2 to select the communications mode (See Step 5).
Reader Links
Set SW1 switch2 (COM) to W for Wiegand communications, or C for 20mA current loop communications. Set
SW1 switch1 (USER F/B - Keypad audio feedback) to 1 for sound on, or 0 for sound off.
Using the Reader
Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession;
there is no need, for example, to wait for "GREEN LED’s" to disappear before presenting another.
If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the O
key,
entering your card number, then pressing the P
key.
LED Status Indicator
GREEN – The lock is released and you may open the door.
RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case,
present it again).
YELLOW – Enter your PIN. If you make a mistake, the RED LED’s are momentarily displayed, followed by
YELLOW LED’s, to prompt you to try again.
9600-0605. Installation and User Instructions for S870-EX Keypad
Readers, Issue 1.0x2 26th June 2012. © G4S Technology, 2012.
FCC Notice: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
Any unauthorized modification to this device may void the authority of
the user to operate it. All trademarks acknowledged.
Specifications
Input voltage: 9-14Vdc.
Input current: 120mA @ nom. 12Vdc.
Operating temperature: -40 to 158°F (-40 to 70°C)
Operating humidity: 15 to 90%, non-condensing.
Maximum read range: 4" (100mm).
Approvals: EN300330, EN301489

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Create Date                     : 2012:06:26 15:39:05Z
Modify Date                     : 2012:06:26 15:39:05Z
Producer                        : Corel PDF Engine Version 14.0.0.701
Author                          : Watts;Andrew
Creator                         : CorelDRAW
Title                           : 9600-0605 Issue 1.0x2- S870 Keypad Extreme Installation and User Instruction
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OE5S870

Navigation menu