 Installation & Operation GuideInstallation & Operation Guide MDS 05-2708A01, Rev. DAUGUST 2006 Microwave Data Systems Inc.  MDS TransNET 900 ™ MDS TransNET 2400 ™ Spread SpectrumData Transceiver
 1. Install and connect the antenna system to the transceiver • Use a high-quality gain antenna, mounted in the clear.• Use a low-loss feedline such as LMR 400.• Preset directional antennas in the direction of desired transmission/reception. 2. Connect the data equipment to the radio’s DB-9F DATA connector • Connect only the required pins.   EIA-232, shown below, typically uses only TXD, RXD and GND. (See Page 71 for EIA-485 interface connections.)•Verify the connected data equipment is configured as DTE. The radio is DCE. 3. Apply DC power to the radio. Use the supplied 2-pin connector • Input voltage is 6–30 Vdc. Observe proper polarity. The left pin is positive (+) and the right pin is negative (–). (See Page 17 for details.) 4. Configure with a PC terminal or TransNET Configuration Software • Connect computer to radio’s DIAG connector. See Page 69 for cable wiring.• Set the Mode using the  MODE M  (Master),  MODE R  (Remote), or  MODE X  (Extension) command. (Note: Only  one  Master is permitted in a system.)•Set a unique Network Address (1–65000) using  ADDR  command. Each radio in the system  must  have the same network address.  Tip: Use the last four digits of the Master’s serial number to help avoid conflicts with other users. • Set the baud rate/data interface parameters. Default setting is 9600 bps, 8 data bits, no parity, 1 stop bit. If changes are required, use the  BAUD xxxxx abc  command where  xxxxx  equals the data rate (300–115200 bps) and  abc  equals the communication parameters as follows: a  = Data Bits (7 or 8) b  = Parity (N for None, O for Odd, E for Even c  = Stop Bits (1 or 2)        NOTE:  7N1, 8E2 and 8O2 are not supported. 5. Verify proper operation by observing the LED display • Refer to Table 6 on Page 20 for a description of the status LEDs.•Refine directional antenna headings for maximum received signal strength using the  RSSI  command. (Remotes must be synchronized with the master.)QUICK START GUIDETXDRXDGNDRTSTXDRXDGND2374325DB-25DATA EQUIPMENT(DTE)DB-9TRANSCEIVER(DCE)5206CTSDTRDSRTXDRXDGNDDTRTXDRXDGND3254325DB-9 DB-9TRANSCEIVER(DCE)678DSRRTSCTSDATA EQUIPMENT(DTE)JUMPERS:Only if required by RTU.See manual for additional details.JUMPERS:Only if required by RTU.See manual for additional details.
 MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide i CONTENTS 1.0   ABOUT THIS MANUAL..........................................................1 2.0   PRODUCT DESCRIPTION....................................................12.1   Transceiver Features .......................................................12.2   Model Number Codes .....................................................22.3   Spread Spectrum Radios—How Are They Different?  .....22.4   Typical Applications .........................................................2Multiple Address Systems (MAS) ....................................2Point-to-Point System ......................................................3Adding a Tail-End Link to an Existing Network ................3Extending a TransNET Network with a Repeater.............42.5   Accessories  ....................................................................5 3.0   INSTALLATION PLANNING...................................................63.1   General Requirements ....................................................63.2   Site Selection ..................................................................6Terrain and Signal Strength .............................................7Conducting a Site Survey ................................................73.3   A Word About Radio Interference  ...................................83.4   Antenna & Feedline Selection .........................................9Antennas..........................................................................9Feedlines .........................................................................10Antenna System Ground .................................................113.5   How Much Output Power Can be Used?  ........................12 4.0   INSTALLATION ......................................................................144.1   Transceiver Installation ....................................................144.2   Configuring Multiple Remote Units  .................................184.3   Tail-End Links ..................................................................184.4   Configuring a Network for Extensions .............................19 5.0   OPERATION ..........................................................................195.1   Initial Start-up ..................................................................19
 ii MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 5.2   Performance Optimization  .............................................. 20Antenna Aiming............................................................... 20Antenna SWR Check ...................................................... 20Data Buffer Setting—Modbus Protocol ........................... 21Hoptime Setting............................................................... 21TotalFlow™ Protocol at 9600 with Sleep Mode............... 21Operation at 115200 bps................................................. 21Baud Rate Setting........................................................... 21Radio Interference Checks.............................................. 22 6.0   RADIO PROGRAMMING ...................................................... 226.1   Radio Programming Methods ......................................... 22Terminal Interface............................................................ 22PC-Based Configuration Tool .......................................... 226.2   User Commands  ............................................................23Entering Commands ....................................................... 236.3   Detailed Command Descriptions .................................... 28ADDR [1–65000]............................................................. 29 Network Address AMASK [0000 0000–FFFF FFFF]...................................29 Alarm Mask AT [ON, OFF] .................................................................. 29 Hayes-Compatible AT Command Support ASENSE [HI/LO] ............................................................. 29 Alarm Output Sense BAUD [xxxxx abc]............................................................ 29 Data Interface Port Baud Rate BAND [A, B, C]................................................................ 30 Select Sub-Band (Normally used for 2.4 GHz model) BUFF [ON, OFF] ............................................................. 30 Data Buffer Mode CODE [NONE, 1…255]................................................... 31 Security Code CSADDR [1–65000, NONE]............................................ 31 Clock-Synchronizing Master Address CTS [0–255].................................................................... 31 Clear-to-Send Delay
 MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide iiiCTSHOLD [0–60000].......................................................32 Clear-to-Send Hold Time DEVICE [DCE, CTS  KEY] ..............................................32 Radio-MODEM Behavior DLINK [xxxxx/ON/OFF]....................................................32 InSite Diagnostics Link Support DKEY...............................................................................33 Turn Off Radio Transmitter ‘s Test Signal DTYPE [NODE/ROOT] ....................................................33 Network Diagnostics Mode FEC [ON, OFF]................................................................33 Forward Error Correction HOPTIME [7, 14, 28] .......................................................34 Radio Transmitter Hop Timing INIT..................................................................................34 Initialize; Restore to Factory Defaults HREV...............................................................................35 Hardware Revision KEY..................................................................................35 Turn On Radio Transmitter Test Signal LED [ON, OFF] ................................................................36 Enable/Disable PCB LEDs LPM [1, 0] ........................................................................36 Low-Power Mode—Masters Only LPMHOLD [0–1000] ........................................................36 Low-Power Mode Sleep Time MODE [M, R, X]...............................................................36 Radio Operating Mode MRSSI [NONE, –40...–90]...............................................37 Minimum RSSI for Mobile Operation OT [ON, OFF] ..................................................................37 Output Trigger OWM [xxxxx]....................................................................37 “Owner’s Message” OWN [xxxxx] ....................................................................37  “Owner’s Name”
 iv MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D PORT [RS232, RS485] ................................................... 37 Data Interface Port Signaling Standard PWR [20–30]................................................................... 38 Radio Transmitter Power Level REPEAT [0–10] ............................................................... 38 Downstream Repeat Transmission Count RETRY [0–10] ................................................................. 38 Upstream Repeat Transmission Count RSSI................................................................................ 38 Received Signal Strength Indicator RTU [ON, OFF, 0-80]....................................................... 39 Remote Terminal Unit Simulator RX [xxxx].........................................................................39 Radio Receive Test Frequency RXD [0–235] / [ON/OFF].................................................39 RXD Delay RXTOT [NONE, 0–1440]................................................. 40 Receive Data Timeout-Timer SAF [ON, OFF]................................................................ 40 Store-and-Forward Services Support SETUP ............................................................................ 40 Setup Radio Test SER................................................................................. 40 Radio Serial Number SHOW CON .................................................................... 41 Show Virtual Connection Status SHOW PWR.................................................................... 41 Show Measured RF Transmit Power SHOW SYNC .................................................................. 41 Show Clock-Synchronization Master Network Address SKIP [NONE, 1...8].......................................................... 41 Skip Radio Operating Zones SLEEP [ON, OFF]...........................................................42 Transceiver Sleep—Remotes Only SREV .............................................................................. 42 Firmware Revision Level
 MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide vSTAT ................................................................................43 Alarm Status TEMP...............................................................................43 Radio’s Internal Temperature TX [xxxx]..........................................................................43 Radio Transmit Test Frequency UNIT [10000–65000] .......................................................43 Unit Address XADDR [0–31] .................................................................44 Extended Address XMAP [00000000-FFFFFFFF].........................................44 Map of Extension Addresses XPRI [0–31] .....................................................................44 Primary Extended Address XRSSI [NONE, –40...–120]..............................................44 Extension RSSI Level ZONE CLEAR..................................................................44 Clear Zone Statistics Log ZONE DATA .....................................................................44 Read Zone Statistics Log 7.0   TROUBLESHOOTING ...........................................................457.1   LED Indicators  ................................................................467.2   Alarm Codes  ...................................................................46Checking for Alarms—STAT command............................46Major Alarms versus Minor Alarms..................................46Alarm Code Definitions....................................................477.3   Troubleshooting Chart .....................................................487.4   Performing Network-Wide Remote Diagnostics ..............497.5   Internal Fuse Replacement .............................................50 8.0   RADIO FIRMWARE UPGRADES ..........................................518.1   Obtaining New Firmware  ................................................51Saving a Web-Site Firmware File Onto Your PC..............518.2   Installing Firmware Into Your Radio .................................51 9.0   OPERATING PRINCIPLES AND CONFIGURATION.............52
 vi MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 9.1   SAF Operation with Extension Radios  ........................... 52Simple Extended SAF Network....................................... 52Extended SAF Network................................................... 53Retransmission and ARQ Operation............................... 53SAF Configuration Example............................................ 539.2   Synchronizing Network Units  .........................................54Synchronization Messages ............................................. 559.3   Using AT Commands ...................................................... 559.4   Configuration Parameters for            Store-and-Forward Services  ....................................... 579.5   Using the Radio’s Sleep Mode (Remote Units Only) ...... 59Sleep Mode Example...................................................... 609.6   Low-Power Mode (LPM)—Master Enabled  .................... 60Setup Commands ...........................................................60Reading RSSI and Other Parameters        with LPM Enabled .................................................... 61Power Consumption Influence by        HOPTIME and SAF Settings.................................... 619.7   Low-Power Mode versus Remote’s Sleep Mode ............629.8   Mobile Operation Support  .............................................. 62Introduction ..................................................................... 62Operational Influences—Hoptime & SAF........................ 639.9   MIRRORED BITS™ Protocol Support  ...........................639.10    Seamless Mode Emulation .......................................... 639.11   Full-Duplex Emulation  .................................................. 639.12   Co-Located and Close-Proximity Masters .................... 63  Master Station Configuration......................................... 64  Antenna System for Co-Located Master Stations ......... 649.13   Security  ........................................................................65 10.0    TECHNICAL REFERENCE ................................................ 6610.1   Product Specifications—900 MHz ................................ 6610.2   Product Specifications—2.4 GHz ................................. 6710.3   Diagnostic Interface Connections (RJ-11) .................... 6910.4   Data Interface Connections (DB-9F)  ............................ 69  Pin Descriptions—RS/EIA-232 Mode............................ 70  Pin Descriptions—RS/EIA-422/485 Mode..................... 7110.5   User Configurable I/O Connections .............................. 72  Using the I/O Points with InSite™ NMS Software ......... 73
 MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide viiApplication Example—Digital Input and Output at a Remote .........................................................7310.6   dBm-Watts-Volts Conversion Chart  ..............................74 Copyright Notice This Installation and Operation Guide and all software described herein are Copyright 2006 by Microwave Data Systems Inc. All rights reserved. Microwave Data Systems Inc. reserves its right to correct any errors and omissions in this manual. MDS Quality Policy Statement We, the employees of Microwave Data Systems, are committed to understanding and exceeding our customer’s needs and expectations.• We appreciate our customers’ patronage. They are our business.• We promise to serve them and anticipate their needs.•We are committed to providing solutions that are cost effective, innovative and reliable, with consistently high levels of quality.We are committed to the continuous improvement of all of our systems and processes, to improve product quality and increase customer satisfaction. RF Exposure Notice ISO 9001 Registration Microwave Data Systems adheres to the internationally-accepted ISO 9001 quality system stan-dard. UL/CSA Notice The MDS TransNET 900 is available for use in Class I, Division 2, Groups A, B, C & D Haz-ardous Locations. Such locations are defined in Article 500 of the National Fire Protection Asso-ciation (NFPA) publication  NFPA 70 , otherwise known as the National Electrical Code. (Approval of the MDS TransNET 2400 is pending as of August 2006.)The transceiver has been recognized for use in these hazardous locations by two independent agencies —Underwriters Laboratories (UL) and the Canadian Standards Association (CSA). The UL certification for the transceiver is as a Recognized Component for use in these hazardous locations, in accordance with UL Standard 1604, UL508. The CSA Certification is in accordance with CSA STD C22.2 No. 213-M1987. UL/CSA Conditions of Approval: The transceiver is not acceptable as a stand-alone unit for use in the hazardous locations described above. It must either be mounted within another piece of equipment which is certified for hazardous locations, or installed within guidelines, or conditions of approval, as set forth by the approving agencies. These conditions of approval are as follows:1. The transceiver must be mounted within a separate enclosure which is suitable for the intended application.2. The coaxial antenna cable, power input cable and interface cables must be routed through conduit in accordance with Division 2 wiring methods as specified in the National Electrical Code, Article 501.4(B).3. The transceiver must be used within its Recognized “Ratings”.Professional installation required. The radio equipment described in this guide emits radio frequency energy. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come closer than 23 cm (9 inches) to the antenna when the transmitter is oper-ating in indoor or outdoor environments in the 900 MHz band or 11.2 cm (4.4 inches) in the 2400 MHz band. More information on RF exposure is available on the Internet at  www.fcc.gov/oet/info/documents/bulletins .RF EXPOSURE
 viii MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D  4. Installation, operation and maintenance of the transceiver should be in accordance with the transceiver's installation manual, and the National Electrical Code.5. Tampering or replacement with non-factory components may adversely affect the safe use of the transceiver in hazardous locations, and may void the approval.6. A power connector with screw-type retaining screws as supplied by MDS must be used.When installed in a Class I, Div. 2, Groups A, B, C or D hazardous location, observe the fol-lowing:  WARNING  EXPLOSION HAZARD    Do not disconnect equipment unless power has been switched off or the area is know to be non-hazardous. Refer to Articles 500 through 502 of the National Electrical Code (NFPA 70) for further infor-mation on hazardous locations and approved Division 2 wiring methods. FCC Part 15 Approval Notice The MDS TransNET 900™ (FCC ID: E5MDS-EL805) and MDS TransNET 2400™ trans-ceivers (Pending FCC ID: E5MDS-EL805-24) comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device is specifically designed to be used under Section 15.247 of the FCC Rules and Regulations. Any unauthorized modification or changes to this device without the express approval of Microwave Data Systems may void the user’s authority to operate this device. Furthermore, this device is intended to be used only when installed in accordance with the instructions outlined in this manual. Failure to comply with these instructions may also void the user’s authority to operate this device. Manual Revision and Accuracy While every reasonable effort has been made to ensure the accuracy of this manual, product improvements may result in minor differences between the manual and the product shipped to you. If you have additional questions or need an exact specification for a product, please contact our Customer Service Team using the information at the back of this guide. In addition, manual updates can often be found on the MDS Web site at  www.microwavedata.com.ESD NoticeTo prevent malfunction or damage to this radio, which may be caused by Electro-static Discharge (ESD), the radio should be properly grounded by connection to the ground stud on the rear panel. In addition, the installer or operator should follow proper ESD precautions, such as touching a grounded bare metal object to dissipate body charge, prior to adjusting front panel controls or connecting or disconnecting cables on the front or rear panels.Environmental InformationThe equipment that you purchased has required the extraction and use of natural resources for its production. Improper disposal may contaminate the environment and present a health risk due to hazardous substances contained within. To avoid dissem-ination of these substances into our environment, and to diminish the demand on nat-ural resources, we encourage you to use the appropriate recycling systems for disposal. These systems will reuse or recycle most of the materials found in this equipment in a sound way. Please contact MDS or your supplier for more information on the proper disposal of this equip-ment.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 11.0 ABOUT THIS MANUALThis manual presents installation and operating instructions of the MDS TransNET 900™ and MDS TransNET 2400™ transceivers for use by a professional installer. This person is expected to install, operate, and perform basic system maintenance on the described radio. Following instal-lation, we suggest keeping this manual near the equipment for future refer-ence.2.0 PRODUCT DESCRIPTIONThe transceiver, shown in Figure 1, is a spread spectrum radio designed for license-free operation. These units employ Digital Signal Processing (DSP) technology to provide highly-reliable long-distance communications, even in the presence of weak signals or interference.DSP technology also makes it possible to obtain information about radio operation and troubleshoot problems, without going to the Remote radio site. Using appropriate software at the Master station, diagnostic data can be obtained on any DSP radio in the system, even while payload data is being transmitted. (See “Performing Network-Wide Remote Diagnostics”  on Page 49.)The transceiver is housed in a compact and rugged die-cast enclosure that need only be protected from direct exposure to the weather. It contains a single printed circuit board with all necessary components for radio opera-tion. No jumper settings or manual adjustments are required to configure the radio for operation.2.1 Transceiver FeaturesListed below are several key features of the transceiver. These are designed to ease the installation and configuration of the radio, while retaining the ability to make changes in the future.• 902–928 MHz operation using the The TransNET 900• 2406–2482 MHz ISM band operation with the TransNET 2400• User-selectable option to skip sub-bands with constant interferenceFigure 1. MDS TransNETSeries Transceiver
2MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D • 65,000 available network addresses• Network-wide configuration from the Master station eliminates most trips to Remote sites•Data transparency ensures compatibility with virtually all asynchronous SCADA system RTUs• Peak-hold RSSI averaged over eight hop cycles• Operation at up to 115,200 bps continuous data flow• Store-and-Forward repeater operation• Data latency typically less than 10 ms• Same hardware for Master or Remote configuration• Supports RS/EIA-232 and RS/EIA-485 user interface• Low current consumption; typically less than 3 mA in “sleep” modeNOTE:  Some radio features may not be available on all models, or limited by the options purchased, or the applicable regulatory constraints for the region in which the radio will operate.2.2 Model Number CodesThe radio model number is printed on the label on the end of the radio’s enclo-sure. It provides key information about how the radio was configured when it was shipped from the factory. This number is subject to many variations depending on what options are installed and where (country) the product is used. Contact MDS is you have questions on the meaning of the code.2.3 Spread Spectrum Radios—    How Are They Different?The main difference between a traditional (licensed) radio and the MDS TransNET transceiver is that this unit “hops” from channel to channel many times per second using a specific hop pattern applied to all radios in the network. A distinct hopping pattern is provided for each of the 65,000 avail-able network addresses, thereby minimizing the chance of interference with other spread spectrum systems. In the USA, and some other countries, no license is required to install and operate this type of radio system, provided that RF power and antenna gain restrictions are observed.2.4 Typical ApplicationsMultiple Address Systems (MAS)This is the most common application of the transceiver. It consists of a central control station (Master) and two or more associated Remote units, as shown in Figure 2. An MAS network provides communications between a central host computer and remote terminal units (RTUs) or other data collection
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 3devices. The operation of the radio system is transparent to the computer equipment. When used in this application, the transceiver provides an excel-lent alternative to traditional (licensed) MAS radio systems.Invisible place holderFigure 2. Typical MAS NetworkPoint-to-Point SystemA point-to-point configuration (Figure 3) is a simple arrangement consisting of just two radios—a Master and a Remote. This provides a half-duplex communications link for the transfer of data between two locations.Invisible place holderFigure 3. Typical Point-to-Point LinkAdding a Tail-End Link to an Existing NetworkA tail-end link can be used to extend the range of a traditional (licensed) MAS system. This might be required if an outlying site is blocked from the MAS Master station by a natural or man-made obstruction. In this arrangement, a MDS TransNETRemoteMDS TransNETRemoteMDS TransNETMasterMDS TransNETRemoteMDS TransNETRemoteRTURTURTURTUHost SystemRXDTXDSYNCPWRRXDTXDSYNCPWRRXDTXDSYNCPWRRXDTXDSYNCPWRRXDTXDSYNCPWRMDS TransNETMasterMDS TransNETRemoteHost System
4MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D TransNET radio links the outlying Remote site into the rest of a licensed MAS system by sending data from that site to an associated TransNET installed at one of the licensed Remote sites (see Figure 4).As the data from the outlying site is received at the licensed Remote site, it is transferred to the licensed radio (via a local cable connection) and is then transmitted to the MAS Master station in the usual manner. Additional details for tail-end links are given in Section 4.3 (Page 18).Invisible place holderFigure 4. Typical Tail-End Link ArrangementExtending a TransNET Network with a RepeaterSimilar to a Tail-End Link, Store-and-Forward (SAF) offers a way to physi-cally extend the network range, but in a simple and economical manner. SAF works by dividing a network into a vertical hierarchy of two or more sub-networks. Extension radios (designated as MODE X) serve as single-radio repeaters that link adjacent sub-networks, and move data from one sub-network to the next one. Invisible place holderFigure 5. TransNET Repeater NetworkPWR SYNC TXD RXDMDS TransNETMasterREPEATER STATIONMDS x710BSeries RadioENTERESCAPEACTIVEACTIVESTBY ALARM RX ALRTX ALRSTBYALARM RX ALR TX ALRLINELINEPWR SYNC TXD RXDNull-Modem CableRemoteRadioRemoteRadioMDS TransNETRemoteMaster StationSPREAD SPECTRUM LINKTO OUTLYING SITEOUTLYINGREMOTE SITEMAS SYSTEM (LICENSED OR UNLICENSED) LICENSE-FREE SPREAD SPECTRUM SYSTEMRTURTU RTUMDS TransNETExtensionMODE = XREPEATER STATIONMDS TransNETRemoteMODE = RSPREAD SPECTRUM LINKTO OUTLYING SITEOUTLYINGREMOTE SITEMDS TransNETRemoteMODE = RMDS TransNETRemoteMODE = RMDS TransNETMasterMODE = MSAF = ONRTURTU RTURTU
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 52.5 AccessoriesThe transceiver can be used with one or more of the accessories listed in Table 1. Contact the factory for ordering details.Table 1. Accessories  Accessory Description MDS Part No.AC Power Adapter  Small power supply module designed for con-tinuous service. UL approved. Input: 120/220 VacOutput: 12 Vdc @ 500 mA (20 Watts) 01-3682A022-Pin DC Power Plug Mates with power connector on the transceiver. Screw terminals are provided for wires. 73-1194A39Fuse (Internal) Fuse, 2A SMF Slo-Blo 29-1784A03Omnidirectional Antennas Rugged antennas suited for use at Master stations. Consult MDS for details. Various; Consult factory900 MHz Yagi Antennas Rugged directional antennas suited for use at Remote stations. Consult MDS for details. Various; Consult factory2400 MHzAntennas Rugged directional antennas suited for use at Remote stations. Various; Consult factory900 MHz Bandpass Filter Antenna system filter to aid in eliminating inter-ference from paging system transmissions. 20-2822A02TNC-to-N Adapter Cable(3 ft./1 meter)Coaxial cable used to connect the radio’s TNC antenna connector to a Type-N style commonly used on large-diameter coaxial cables.97-1677A159TNC-to-N Adapter Cable(6 ft./1.8 meter)Coaxial cable used to connect the radio’s TNC antenna connector to a Type-N style commonly used on large-diameter coaxial cables.97-1677A160TNC-to-N RF Adaptor Plug Adapts radio’s antenna connector to Type-N style commonly used on large-diameter coaxial cables.97-1677A161RS/EIA-232Cable Shielded data cable fitted with DB-9 male and DB-9 female, 6 ft./1.8 meter. 97-1971A03RJ-11 to DB-9 Adapter Cable For connecting a PC terminal to the transceiver via the radio’s DIAG(nostics) connector. Used for programming and diagnostics.03-3246A01Flat-Surface Mounting BracketsBrackets: 2˝ x 3˝ plates designed to be screwed onto the bottom of the transceiver for sur-face-mounting the radio.82-1753-A01Mounting Bracket Screws Screws: 6-32/1/4˝ with locking adhesive. (Industry Standard MS 51957-26) 70-2620-A0119-Inch Rail Mounting BracketsAdaptor for mounting the radio in a standard 19-inch equipment rack. Consult FactoryDIN Rail Mtg. Brackets Adaptor for mounting the radio in a standard 19-inch equipment rack. 03-4022A01
6MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 3.0 INSTALLATION PLANNINGThe installation of the radio is not difficult, but it does require some planning to ensure station reliability and efficiency. This section provides tips for selecting an appropriate site, choosing an antenna system, and reducing the chance of harmful interference.3.1 General RequirementsThere are three main requirements for installing the radio—adequate and stable primary power, a good antenna system, and the compatible interface between the transceiver and the data device.Figure 6 shows a typical Remote station arrangement. Master stations are similar, but an omni-directional antenna is normally used instead of a direc-tional type, and a host computer replaces the data terminal equipment.Invisible place holderFigure 6. Typical Remote Station Arrangement3.2 Site SelectionFor a successful installation, careful thought must be given to selecting proper sites for the Master and Remote stations. Suitable sites should provide the following:• Protection from direct weather exposure•A source of adequate and stable primary power• Suitable entrances for antenna, interface or other required cabling•Antenna location that provides an unobstructed transmission path in the direction of the associated station(s)POWER SUPPLY13.8 VDC @ 500 mA(6–30 Vdc)DATA TERMINALEQUIPMENTMDS TransceiverLOW-LOSS FEEDLINEANTENNASYSTEM
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 7These requirements can be quickly determined in most cases. A possible exception is the last item—verifying that an unobstructed transmission path exists. Radio signals travel primarily by line-of-sight, and obstructions between the sending and receiving stations will affect system performance. If you are not familiar with the effects of terrain and other obstructions on radio transmission, the discussion below will provide helpful background.Terrain and Signal StrengthWhile the 900 and 2400 MHz bands offer many advantages over VHF and lower UHF frequencies for data transmission, they are more prone to signal attenuation from obstructions such as terrain, foliage or buildings in the trans-mission path.A line-of-sight transmission path between the Master station and its associ-ated Remote site(s) is highly desirable and provides the most reliable commu-nications link. A line-of-sight path can often be achieved by mounting the station antenna on a tower or other elevated structure that raises it to a level sufficient to clear surrounding terrain and other obstructions.The importance of a clear transmission path relates closely to the distance to be covered by the system. If the system is to cover only a limited geographic area, say up to 3 miles (4.8 km), then some obstructions in the communica-tions path can usually be tolerated with minimal impact. For longer range systems, any substantial obstruction in the communications path could compromise the performance of the system, or block communications entirely.Much depends on the minimum signal strength that can be tolerated in a given system. Fade margin for a TransNET system does not usually have to be as conservative as a licensed system. The nature of TransNET’s frequency-hopping algorithm reduces the impact of frequency-selective fading.Although the exact figure will differ from one system to another, a Received Signal Strength Indication (RSSI) of –100 dBm will often provide acceptable performance. A higher signal strength is generally desirable and may be needed in special cases—for example, urban deployment.Conducting a Site SurveyIf you are in doubt about the suitability of the radio sites in your system, it is best to evaluate them before a permanent installation is begun. This can be done with an on-the-air test (preferred method), or indirectly, using path-study software.An on-the-air test is preferred because it allows you to see firsthand the factors involved at an installation site and to directly observe the quality of system operation. Even if a computer path study was conducted earlier, this test should be done to verify the predicted results.The test can be performed by first installing a radio and antenna at the proposed Master station site and then visiting each Remote site with a trans-ceiver and a hand-held antenna.
8MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D With the hand-held antenna positioned near the proposed mounting spot, a technician can check for synchronization with the Master station (shown by a lit SYNC lamp on the front panel) and measure the reported RSSI value. If adequate signal strength cannot be obtained, it may be necessary to mount the station antennas higher, use higher gain antennas, or select a different site. To prepare the equipment for an on-the-air test, follow the general installation procedures given in this guide and become familiar with the operating instructions given in Section 5.0, beginning on Page 19.If time is short, and a site survey is impractical, a computer path study is a good alternative. Factors such as terrain, distance, transmitter power, receiver sensitivity, and other conditions are taken into account to predict the perfor-mance of a proposed system. Contact MDS’ Technical Services Group for more information on path study services.3.3 A Word About Radio InterferenceThe radio shares the frequency spectrum with other services and other Part 15 (unlicensed) devices in the USA. As such, near 100% error free communica-tions may not be achieved in a given location, and some level of interference should be expected. However, the radio’s flexible design and hopping tech-niques should allow adequate performance as long as care is taken in choosing station location, configuration of radio parameters and soft-ware/protocol techniques.In general, keep the following points in mind when setting up your commu-nications network:1. Systems installed in rural areas are least likely to encounter interference; those in suburban and urban environments are more likely to be affected by other devices operating in the license-free frequency band and by adjacent licensed services.2. If possible, use a directional antenna at Remote sites. Although these antennas may be more costly than omnidirectional types, they confine the transmission and reception pattern to a comparatively narrow lobe, which minimizes interference to (and from) stations located outside the pattern.3. If interference is suspected from a nearby licensed system (such as a paging transmitter), it may be helpful to use horizontal polarization of all antennas in the network. Because most other services use vertical polarization in these bands, an additional 20 dB of attenuation to interference can be achieved by using horizontal polarization.4. Multiple transceiver systems can co-exist in proximity to each other with only very minor interference as long as they are each assigned a unique network address. Each network address has a different hop pattern.Additional RF isolation can be achieved by using separate directional antennas with as much vertical or horizontal separation as is practical. Vertical separation of antennas is more effective per foot/meter than horizontal.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 95. If constant interference is present in a particular frequency zone, it may be necessary to “lock out” that zone from the radio’s hopping pattern. The radio includes built-in tools to help users remove blocked frequency zones. Refer to the discussion of the SKIP command (Page 41) for more information. In the USA, a maximum of four zones may be skipped, per FCC rules. Check the regulatory requirements for your region.6. Interference can also come from out-of-band RF sources such as paging systems. Installation of a bandpass filter in the antenna system may bring relief. (Contact the MDS Customer Service Department for recommendations and sources of suitable filters.)7. Proper use of the RETRY and REPEAT commands may be helpful in areas with heavy interference.The RETRY command sets the maximum number of times (0 to 10) that a radio will re-transmit upstream data over the air. Values greater than 0 successively improve the chances of a message getting through when interference is a problem. The REPEAT command sets a fixed number of unconditional retransmissions for downstream data.8. The RF power output of all radios in a system should be set for the lowest level necessary for reliable communications. This lessens the chance of causing unnecessary interference to nearby systems.3.4 Antenna & Feedline SelectionAntennasThe equipment can be used with a number of antennas. The exact style used depends on the physical size and layout of a system. Contact your MDS repre-sentative for specific recommendations on antenna types and hardware sources.In general, an omnidirectional antenna (Figure 7 and Figure 8) is used at the Master station site in an MAS system. This provides equal coverage to all of the Remote sites.NOTE:  Antenna polarization is important. If the wrong polarization is used, a signal re-duction of 20 dB or more will result. Most systems using a gain-type omnidirec-tional antenna at the Master station employ vertical polarization of the signal; therefore, the Remote antenna(s) must also be vertically polarized (elements oriented perpendicular to the horizon). When required, horizontally polarized omnidirectional antennas are also avail-able. Contact your MDS representative for details.
10 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D At Remote sites and point-to-point systems, a directional Yagi antenna (Figure 8), is generally recommended to minimize interference to and from other users. Antennas are available from a sources including MDS.Invisible place holderFigure 8. Typical Yagi Antenna mounted to a mastFeedlinesThe choice of feedline used with the antenna should be carefully considered. Poor-quality coaxial cables should be avoided, as they will degrade system performance for both transmission and reception. The cable should be kept as short as possible to minimize signal loss.For cable runs of less than 20 feet (6 meters), or for short range transmission, an inexpensive type such as Type RG-8A/U may be acceptable. Otherwise, we recommend using a low-loss cable type suited for 900 MHz, such as Times Microwave LMR 400® or Andrew Heliax®.Figure 7. Omnidirectional Antenna (mounted to mast)
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 11Table 2 lists several types of feedlines and indicates the signal losses (in dB) that result when using various lengths of each cable at 900 MHz and Table 3 for 2.4 GHz. The choice of cable will depend on the required length, cost considerations, and the amount of signal loss that can be tolerated. Antenna System GroundPrecautions should be taken to assure the antenna and its support structure are bonded to a good earth ground system to minimize the impact of voltages created by lightning and atmospheric charges.CAUTION:  Safety grounding systems are beyond the scope of this manual. Below you will find some elementary advice. These are generalities; every location and installation is unique and requires a unique safety grounding system design. Please consider consulting a radio system engineer or other professional for advice or ground system design. A well-designed ground system will mini-mize risk of electrical shock to personnel and the chances of equipment damage.Table 2. Length vs. loss in coaxial cables at 900 MHzCable Type10 Feet(3.05 Meters)50 Feet(15.24 Meters)100 Feet(30.48 Meters)300 Feet(91.44 Meters)LMR 400 0.39 dB 1.95 dB 3.9 dB Unacceptable Loss1/2 inchHELIAX 0.23 dB 1.15 dB 2.29 dB 6.87 dB7/8 inchHELIAX 0.13 dB 0.64 dB 1.28 dB 3.84 dB1-1/4 inchHELIAX 0.10 dB 0.48 dB 0.95 dB 2.85 dB1-5/8 inchHELIAX 0.08 dB 0.40 dB 0.80 dB 2.4 dBTable 3. Length vs. loss in coaxial cables at 2400 MHz Cable Type10 Feet(3.05 Meters)50 Feet(15.24 Meters)100 Feet(30.48 Meters)300 Feet(91.44 Meters)LMR-400 0.70 dB 3.50 dB 6.61 dB Unacceptable Loss1/2 inch HELIAX 0.35 dB 1.73 dB 3.46 dB 17.3 dB7/8 inch HELIAX 0.20 dB 0.99 dB 1.97 dB 9.85 dB1-1/4 inch HELIAX 0.15 dB 0.73 dB 1.45 dB 7.50 dB
12 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Antenna Selection—Choose an antenna that offers a “DC ground” or direct low-impedance ground connection for all metallic components. This will allow static charges on the antenna system to be safely dissipated to ground. It will also provide a low-impedance discharge path to an earth/safety ground in the event of a direct lightning strike.Support Earth/Safety Ground—The structure that supports your antenna system should have a large-gauge ground wire that goes as directly as possible to an safety/earth ground system. If a tower is used, it should have its own ground system. Support structure grounds can be bonded to the elec-trical system ground for increased protection. Do not use the building’s AC-power supply ground as a safety ground for lightning protection.Chassis Ground—Connect a safety/earth ground to the ground post provided on the electronic/electrical equipment. If a ground terminal is present, bond the chassis to the safety ground at a point that is as close as possible to the antenna system and primary power entry points on the chassis.3.5 How Much Output Power Can be Used?The transceiver is normally supplied from the factory set for an RF power of +30 dBm (1 Watt) for 900 MHz and +27 dBm (0.5 Watt) for 2400 MHz; this is the maximum transmitter output power allowed under FCC rules. The power must be decreased from this level if the antenna system gain exceeds 6 dBi. The allowable level is dependent on the antenna gain, feedline loss, and the transmitter output power setting. Power considerations for the transceiver are discussed below.NOTE:  In some countries, the maximum allowable RF output may be limited to less than your model’s peak output. Be sure to check for and comply with the require-ments for your region.To determine the maximum allowable power setting of the radio, perform the following steps:1. Determine the antenna system gain by subtracting the feedline loss (in dB) from the antenna gain (in dBi). For example, if the antenna gain is 9.5 dBi, and the feedline loss is 1.5 dB, the antenna system gain would be 8 dB. (If the antenna system gain is 6 dB or less, no power adjustment is required.)2. Subtract the antenna system gain from 36 dBm (the maximum allowable EIRP). The result indicates the maximum transmitter power (in dBm) allowed under the rules. In the example above, this is 28 dBm.3. If the maximum transmitter power allowed in your region is less than 30 dBm, use the PWR command (described on Page 38) to set the power accordingly.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 13For convenience, Table 4 lists several antenna system gains and shows the maximum allowable power setting of the radio. Note that a gain of 6 dB or less entitles you to operate the radio at full power output—30 dBm (1 watt).Table 4. Antenna system gain vs. power output setting (USA)for 900 MHz models to achieve +36 dBm EIRPAntenna System Gain(Antenna Gain in dBiaminus Feedline Loss in dBb)a. Most antenna manufacturers rate antenna gain in dBd in their literature. To convert to dBi, add 2.15 dB.b. Feedline loss varies by cable type and length. To determine the loss for common lengths of feedline, see Table 2 on Page 11.Maximum PowerSetting(in dBm)EIRP(in dBm)6 (or less) 30 368283610 26 3612 24 3614 22 3616 20 36Table 5. Antenna system gain vs. power output setting (USA)for 2400 MHz models to achieve +36 dBm EIRPAntenna System Gain(Antenna Gain in dBiaminus Feedline Loss in dBba. Most antenna manufacturers rate antenna gain in dBd in their literature. To convert to dBi, add 2.15 dB.b. Feedline loss varies by cable type and length. To determine the loss for common lengths of feedline, see Table 2 on Page 11.Maximum PowerSetting(in dBm)EIRP(in dBm)2 dB 27 29 10 dB 26 36
14 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 4.0 INSTALLATIONFigure 9 shows the contents of a typical transceiver shipment. Check the contents against the packing list secured to the outside of the shipping box. Accessories and spare parts kits, if any, are wrapped separately. Inspect all items for signs of damage and save all packing materials for possible re-ship-ment.Invisible place holderFigure 9. Typical Transceiver ShipmentUser documentation will be provided as a paper manual and/or as a PDF on the “MDS TransNET Support Package CD” (P/N 03-2708A01). The CD includes:• Installation & Operation Guide in PDF (Also known as Adobe Acrobat™)• TransNET Configuration SoftwareIf a paper copy is required but not provided with your shipment, please contact MDS Customer Support Team.4.1 Transceiver InstallationThe following is an overview of a typical procedure for installing the trans-ceiver. In most cases, these steps alone will be sufficient to complete the installation. Should further information be required, contact the factory using the information given on the inside back cover of this manual.If you are installing a tail-end link system, you should also review Section 4.3 (Page 18) for important details on configuration.NOTE:  It is recommended that the Master station be installed first. In this way, it will be possible to quickly check the operation of each associated Remote station as it is placed on the air.1. Mount the transceiver to a stable surface using the brackets supplied with the radio. (Fasteners/anchors are not supplied.) Figure 10 shows the dimensions of the transceiver case and its mounting brackets. If possible, INSTALLATION &OPERATION GUIDE,AND SOFTWARE(CD AND/OR MANUAL)MDS Xxxx2-PINPOWER PLUGMOUNTINGBRACKETSSPARE FUSE
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 15choose a mounting location that provides easy access to the connectors on the end of the radio and an unobstructed view of the LED status indicators.Invisible place holderFigure 10. Transceiver Mounting DimensionsFigure 11 shows the four connectors on the transceiver and their functions.Invisible place holderFigure 11. Interface Connector Functions2. Install the antenna and antenna feedline for the station. Antennas should be mounted in the clear and in accordance with the manufacturer’s instructions. Additional information on antennas and feedlines is contained in Section 3.4 on Page 9.NOTE:  It is recommended to mount the antenna be at least 10 feet (>3 meters) from the radio, RTU, sensors and other components of the system to prevent RFI.3. Connect the data equipment to the transceiver’s DATA connector. Use only the required pins for the application. 6.63(16.64 cm)2.75(7.0 cm)1.62(4.15 cm)Antenna Primary PowerData (6–30 Vdc)Diagnostic(Communications)(Payload)
16 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Typical RS/EIA-232 applications require the use of Pin 2 (receive data—RXD and Pin 3 (transmit data—TXD). Some systems may require the use of Pin 7 (Request-to-send—RTS). Figure 13 shows connection details for the DATA connector for EIA/RS-232 and EIA/RS-485, respectively.If hardware flow control is desired, Pin 7 (RTS) and Pin 8 (CTS) may also be connected. A more detailed discussion of pin functions is provided in see “Data Interface Connections (DB-9F)” on page 69.Invisible place holderFigure 12. DATA Connector Pin Functions, EIA/RS-232 ModeAs viewed from outside the radioNOTE:  The data cabling between the transceiver and the connected device should be kept as short as possible. For EIA/RS-232 operation, the maximum recom-mended cable length is 50 feet/15 meters.Invisible place holderFigure 13. DATA Connector Pin Functions, EIA/RS-485 ModeAs viewed from outside the radio4. Measure and install the primary power for the transceiver. It must be within 6–30 Vdc (including transients) and be capable of providing 7.5 watts over this voltage range. (Typical current draw is 400 mA @13.8 Vdc; 0.9 A @6 Vdc.) A power connector with screw-terminals is provided with each unit. Strip the wire leads to 0.25˝/6 mm. Be sure to observe proper polarity. The left pin is the positive input; the right is negative. (See Figure 14.)5961Pin Function1.....Data Carrier Detect (DCD)2.....Receive Data (RXD)3.....Transmit Data (TXD)4.....Sleep (GND = Sleep)5.....Signal Ground (GND)6.....Alarm Output (+5/-5 Vdc)7.....Ready-to-Send (RTS)8.....Clear-to-Send (CTS)9.....Reserved for Special Uses (Do not connect)Pin Function1.....Not Used (Open)2.....TXD+/TXA, Non-inverted driver output.Supplies data to connected device.3.....RXD+/RXA, Non-inverted receiver input.Accepts data from the connected device.4.....Sleep Mode Input (GND = Sleep)5.....Signal Ground (GND)6.....Not Used (Open)7.....RXD–/RXB, Inverting receiver input8.....TXD–/TXB, Inverting driver output9.....Not Connected (User configureable via internal jumper)5961
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 17The radio must be used only with negative-ground sys-tems. Make sure the polarity of the power source is cor-rect. The unit is protected from reverse polarity by an internal diode and fuse.Invisible place holderFigure 14. Power Connector(Polarity: Left +, Right –)The power connector used with the MDS TransNET transceiver is similar to that used by other MDS prod-ucts, such as the MDS 9810 and MDS x710 family. The connectors are not equal and the use of the other style connector may provide unreliable connections and a spark may be created. Only the power connector, shown in Figure 14 with screw terminals and two retainer screws should be used with this unit.5. Set the radio’s basic configuration with a PC terminal connected to the DIAG(nostics) connector via an RJ-11 to DB-9 adapter cable, MDS P/N 03-3246A01. (If necessary, a cable of this type may be constructed using the information shown in Figure 21 on Page 69.) For more information on connecting a PC terminal and preparing it for use, refer to Section 6.1 on Page 22.The three essential settings for the Transceiver are as follows:Mode—Master, Remote, or ExtensionNetwork Address—a unique number from 1 to 65000Data Interface Parameters—bps, data bits, parity, stop bitsa. Set the Mode using the MODE M (Master), MODE R (Remote), or MODE X (Extension) command. (Note: There can be only one Mas-ter radio in a system.)If any MODE X radios are used in the network, SAF must be turned on at the Master station. The MODE X radio must be programmed with an Extended Address (XADDR). Units that need to hear the MODE X radio must be programmed with an appropriate XPRI and/or XMAP value. (See “SAF Operation with Extension Radios” on Page 52 for more information.)CAUTIONPOSSIBLEEQUIPMENTDAMAGEWire Ports (2)LeadScrews (2)BindingCAUTIONPOSSIBLEEQUIPMENTDAMAGE
18 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D b. Set a unique Network Address (1–65000) using ADDR command. Each radio in the system must have the same network address. Tip: Use the last four digits of the Master’s serial number to help avoid conflicts with other users.c. Set the baud rate/data interface parameters. Default setting is 9600 bps, 8 data bits, no parity, 1 stop bit. If changes are required, use the BAUD xxxxx abc command where xxxxx equals the data speed (300–115200 bps) and abc equals the communication parameters as follows:a = Data bits (7 or 8)b = Parity (N for None, O for Odd, E for Evenc = Stop bits (1 or 2)NOTE:  7N1, 8E2 and 8O2 are invalid interface parameters.4.2 Configuring Multiple Remote UnitsIn most installations, the Remote radios will be programmed with virtually the same set of parameters. This process can be streamlined by testing key pieces of equipment—such as the Master, any Extensions, and a typical Remote—on a benchtop setup prior to installation. This allows you to test various configurations in a controlled environment. Once the evaluation network is working satisfactorily, you can save the configuration of each unit in a data file on your PC’s hard drive through the use of the MDS TransNET Configuration Software (included on the support CD shipped with the radio, MDS part number 03-2708A01).Most often, there are many Remote units that will need configuring. Using the MDS TransNET Configuration Soft-ware, you can save the sample unit’s configuration, then open the configura-tion file with the program and install it in the next Remote. The software will prevent you from overwriting unit or mode-unique parameters.4.3 Tail-End LinksA tail-end link is established by connecting an MDS TransNET Series radio “back-to-back” with another identical radio such as a licensed MDS x710B Series transceiver. This can be used to link an outlying Remote site into the rest of an MAS network. (Figure 4 on Page 4 shows a diagram of a typical tail-end link system.) The wiring connections between the two radios in a tail-end link system should be made as shown in Figure 15.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 19Figure 15. Data Interface Cable Wiring for Tail-End LinksAny device on the left that requires a keyline, as in this illustration, will require the bottom line (CTS to RTS) and the TransNET on the right will need DEVICE type set to CTS KEY. See DEVICE, on Page 32 for details.4.4 Configuring a Network for ExtensionsThe installation and configuration of an Extension transceiver is straightfor-ward with only a few unique parameters that need to be considered and set at each unit.In every network there can be only one Master station. It will serve as the sole gateway to the outside world. The tables in “Configuration Parameters for Store-and-Forward Services”  on Page 57 detail the parameters that need to be set on each type of radio in the network. For a detailed description of this network design, see “SAF Operation with Extension Radios” on page 52.5.0 OPERATION5.1 Initial Start-upIn-service operation of the transceiver is completely automatic. Once the unit has been properly installed and configured, operator actions are limited to observing the LED status indicators for proper operation.If all parameters are correctly set, start operation of the radio as follows:1. Apply primary power.2. Observe the transceiver LED status panel for proper indications. Table 6 provides an explanation of the LED functions.In a normally operating system, the following indications will be seen within 16 seconds of start-up:•PWR lamp lit continuously•SYNC lamp lit continuouslyIf required.RXDTXDGNDRTS3274DCEDB-25MDS x710B SeriesRemote Transceiver(or device requiring keyline)TXDRXDGNDCTS3258DCEDB-9MDS TransNET 900Remote Transceiver(DEVICE CTS KEY)
20 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D •Remote radio(s) transmitting data (TXD) and receiving data (RXD) with Master station5.2 Performance OptimizationAfter the basic operation of the radio has been checked, you may wish to opti-mize its performance using some of the suggestions given here. The effective-ness of these techniques will vary with the design of your system and the format of the data being sent.Complete instructions for using the commands referenced in this manual are provided in “RADIO PROGRAMMING”  on Page 22.Antenna AimingFor optimum performance, directional antennas must be accurately aimed in the direction of desired transmission. The easiest way to do this is to point the antenna in the approximate direction, then use the Remote radio’s RSSI command (Received Signal Strength Indicator) to further refine the heading for maximum received signal strength.In an MAS system, RSSI readings are only meaningful when initiated from a Remote station. This is because the Master station typically receives signals from several Remote sites, and the RSSI would be continually changing as the Master receives from each Remote in turn. Adjust the antenna for the highest (most positive) value to insure the greatest communication reliability.Table 6. LED indicator descriptionsName DescriptionPWR • Continuous—Power is applied to the radio; no problems detected• Flashing (5 times-per-second)—Fault indicationSee “TROUBLESHOOTING”  on Page 45• Off—Radio is unpowered or in Sleep modeSee also, “LED [ON, OFF]”  on Page 36SYNC Continuous—Radio is receiving/sending synchronization framesOn within 10 seconds of power-up under normal conditionsTXD Transmit data activity on the DB-9 DATA interface connectorPayload data to connected deviceRXD Receive data activity on the DB-9 DATA interface connector.Payload data from the connected devicePWR SYNC TXD RXD
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 21Antenna SWR CheckIt is necessary to briefly key the transmitter for this check by placing the radio in the SETUP mode (Page 40) and using the KEY command. (To unkey the radio, enter DKEY; to disable the SETUP mode and return the radio to normal operation, enter Q or QUIT.)The SWR of the antenna system should be checked before the radio is put into regular service. For accurate readings, a wattmeter suited for 1000 MHz is required. One unit meeting this criteria is the Bird Model 43 directional watt-meter with a 5J element installed.The reflected power should be less than 10% of the forward power (≈2:1 SWR). Higher readings usually indicate problems with the antenna, feedline or coaxial connectors.Data Buffer Setting—Modbus ProtocolThe default setting for the data buffer is OFF. This allows the radio to operate with the lowest possible latency and improves channel efficiency. MODBUS and its derivatives are the only protocols that should require the buffer to be turned on. See “BAND [A, B, C]” on Page 30 for details.Hoptime SettingThe default hop-time setting is 7 (7 ms). Alternate settings of 14 and 28 milli-seconds can be used to increase throughput, but at the cost of increased latency. A detailed explanation of the HOPTIME command can be found on Page 34.TotalFlow™ Protocol at 9600 with Sleep ModeFor reliable operation with TotalFlow meters, use the default settings for 9600 with the following alterations:HOPTIME 28—Allows large data packetsFEC OFF—Improves store-and-forward performance for a large contin-uous data streamBUFF ON—Ensures “ungapped” 4-second polls if unit in sleep modeOperation at 115200 bpsBurst throughput at 115200 bps is supported at all settings. The radio will always buffer at least 500 characters. Sustained throughput at 115200 bps is only possible when the data path is nearly error-free and the operating settings have been properly selected. For sustained operation at 115200 bps, use the following settings: SAF OFF, FEC OFF, REPEAT 0, RETRY 0, HOPTIME 28.
22 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Baud Rate SettingThe default baud rate setting is 19200 bps to accommodate most systems. If your system will use a different data rate, you should change the radio’s data interface speed using the BAUD xxxxx abc command (Page 29). It should be set to the highest speed that can be sent by the data equipment in the system. (The transceiver supports 300 to 115200 bps.)Radio Interference ChecksThe radio operates in eight frequency zones. If interference is found in one or more of these zones, the SKIP command (Page 41) can be used to omit them from the hop pattern. You should also review Section 3.3, A Word About Radio Interference, when dealing with interference problems.6.0 RADIO PROGRAMMINGThere are no manual adjustments on the radio. Programming and control is performed through a PC connected to the radio’s DIAG connector. 6.1 Radio Programming MethodsTerminal InterfaceA PC may be used by operating it in a basic terminal mode (for example, a HyperTerminal session) and entering the radio commands listed in the tables found in “User Commands”  on Page 23. The PC must be connected to the radio’s DIAG connector using an RJ-11 to DB-9 Adapter Cable (MDS P/N 03-3246A01). If desired, a cable of this type may be constructed using the information shown in Figure 21 on Page 69.Once connected, communication (baud rate) is established through the command interface. To access the command interface, press the   key, followed by one or more   keystrokes (delivered at about half-second intervals), until the “>” prompt is displayed.NOTE:  The DIAG port (RJ-11 connector) uses 8 data bits, 1 stop bit, and no parity. It can automatically configure itself to function at 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bps. [Default: BAUD = 9600]If the DLINK setting is ON, the DIAG port will start out in Diagnostic Link mode. This is a special protocol used to support Network-Wide Diagnostics. The pro-cess described in the paragraph above causes the radio to exit the diagnostic link mode and enter the command mode. If there is no input in command mode for 5 minutes, the DIAG port will revert back to diagnostic link mode.PC-Based Configuration ToolThe MS Windows™-based MDS TransNET Configuration Software (P/N 06-4059A01) is designed for use with a PC connected to the radio’s DIAG connector through an RJ-11 to DB-9 cable assembly (MDS Part No. 03-3246A01). A cable of this type may be constructed using the information shown in Figure 21 on Page 69.ESCENTER
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 23The TransNET Configuration Software provides access to all of the radio’s capabilities with the benefit of context-sensitive help. The program is shipped as part of the TransNET support CD included with every order (CD P/N 03-2708A02)6.2 User CommandsA series of tables begin on the next page that provide reference charts of various user commands for the transceiver. See “Detailed Command Descrip-tions” on Page 28 for more details.Entering CommandsThe proper procedure for entering commands is to type the command, followed by an   keystroke. For programming commands, the command is followed by  , the appropriate information or values, and then .  Table 7. Network Configuration—Master Station  COMMAND  DESCRIPTION AT [ON, OFF] Details Page 29 Enables Master station to emulate a modem and respond to AT commandsBUFF [ON, OFF] Details Page 30 ON = Seamless dataOFF = Fast byte throughput.FEC [ON, OFF] Details Page 33 Sets/disables FEC (Forward Error Correction) setting.HOPTIME [7, 28]Details Page 34 Displays hop-time or sets it to 7 or 28 ms.LPM [1, 0]Details Page 36 Used at Master to set all associated stations in an energy-conservation mode.1 = Low-power mode enabled network-wide0 = Disable low-power mode (Default)REPEATDetails Page 38 Sets/displays the fixed downstream re-send count.RETRY [0–10]Details Page 38 Sets/displays the maximum upstream re-send count for ARQ (Automatic Repeat Request) operationSAF [ON, OFF] Details, page 40 Enables/disables the store-and-forward func-tion for the network controlled by this Master unit.SKIP [NONE, 1...8] Details, page 41 Skip one or more frequency zonesENTERSPACEENTER
24 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Table 8. Network-Wide Diagnostics   Command DescriptionDLINK [xxxxx/ON/OFF] Details, page 32 Controls operation of diagnostic link function.DTYPE [NODE/ROOT] Details, page 33 Set radio’s operational characteristics for network-wide diagnosticsTable 9. Operational Configuration—Set/Program  Command DescriptionADDR [1–65000] Details, page 29 Program network addressAMASK [0000 0000–FFFF FFFF] Details, page 29 Alarm responseDefault: FFFF FFFFASENSE [HI/LO] Details, page 29 Sense of the alarm output on Pin 6 of the DATA interface connector in the EIA-232 mode. Default: Alarm present = HIBAND [A, B, C] Details Page 30 Selects one of three operating bands.(2.4 GHz Model Only)BAUD [xxxxx abc] Details, page 29 Data communication parametersCODE [NONE, 1…255] Details, page 31 Select the security/encryption setting in the radioCSADDR [1–65000, NONE] Details, page 31 Used on a single Master/Remote network to support TDD-style simulated full-duplex.CTS [0–255] Details, page 31 CTS delay in milliseconds(A value of 0 returns CTS immediately)CTSHOLD [0–60000] Details, page 32 “Hold time” that CTS is present following last character from DATA port.DEVICE [DCE, CTS  KEY] Details, page 32 Device behavior: DCE (normal) or CTS KeyMODE [M, R, X] Details, page 36 Operating mode: M = Master, R = Remote, X = ExtensionMRSSI [NONE, –40...–90] Details, page 37 Minimum RSSI level required to preserve syn-chronization with a Master radio for Remotes in mobile service.OT [ON, OFF] Details, page 37 Enables a 1-second delay on delivery of RXD serial data.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 25 OWN [xxxxx] Details, page 37 Owner’s name, or alternate message(30 characters maximum)PORT [RS232, RS485] Details, page 37 Data port (DATA connector) interface signaling mode: RS232 or RS485PWR [20–30] Details, page 38 Power output in dBm (Figure 30 on Page 74)RXD [0–235] / [ON/OFF] Details, page 39 Set RXD delay time for virtual seamless mode with low latencyRXTOT [NONE, 0–1440] Details, page 40 Maximum duration (in minutes) before time-out alarm. Default is OFF.RTU [ON, OFF, 0-80] Details, page 39 Enable or Disable unit’s built-in RTU simulator. Default is OFF. Set RTU address between zero and 80.SLEEP [ON, OFF] Details, page 42 Enable or Disable the radio’s energy-conser-vation Sleep mode function.UNIT [10000–65000] Details, page 43 Unit address used for network-wide diagnostics. (Unique within associated net-work.)XADDR [0–31] Details, page 44 This unit’s Extended addressTypically, the Master is set to zero (0).XMAP [00000000-FFFFFFFF] Details, page 44 Included Extended units in MODE X. (Extensions and Remotes only) XPRI [0–31] Details, page 44 Address of the primary Extended radio unit (Extension).XRSSI [NONE, –40...–120] Details, page 44 Minimum RSSI level required to preserve syn-chronization with a non-primary radio. (Only meaningful when XPRI is not NONE)ZONE CLEAR Details, page 44 Reset zone data statisticsTable 10. Operating Status—Display Only Command DescriptionADDRDetails Page 29 Network addressAMASKDetails Page 29 Alarm mask (response)Table 9. Operational Configuration—Set/Program  (Continued)Command Description
26 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D ASENSEDetails Page 29 Current sense of the alarm output.BAUDDetails Page 29 Data communication parameters. Example: BAUD 9600 8N1BUFFDetails Page 30 Data buffering mode: ON = seamless data, OFF = fast byte throughputCODEDetails Page 30 Security/encryption operational status.“NONE” (Inactive), or “ACTIVE”CTSDetails Page 31 CTS delay in milliseconds (0–255 ms)CTSHOLDDetails Page 32 “Hold time” that CTS is present following last character from DATA port.DEVICEDetails Page 32 Device behavior Alternatives: DCE and CTS KEYHOPTIMEDetails Page 34 Hop-time value in milliseconds (ms).LPMHOLDDetails Page 36 Time (0-1000 ms) provided to give an RTU time to respond before the radio goes to sleep.MODEDetails Page 36 Current operating mode: M = MasterR = RemoteX = Extension (Repeater)MRSSIDetails Page 37 Minimum RSSI level required to preserve syn-chronization with a Master radio for Remotes in mobile service.OWMDetails Page 37 Owner’s message or site nameOTDetails Page 37 Status (ON/OFF) of the 1-second delay on delivery of RXD serial data.OWNDetails Page 37 Owner’s name or system namePORTDetails Page 37 Current data port (DATA connector) interface signaling mode: RS232 or RS485PWRDetails Page 38 Forward power-output setting in dBmTable 10. Operating Status—Display Only (Continued)Command Description
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 27REPEATDetails Page 38 The fixed downstream re-send count.RETRYDetails Page 38 The maximum upstream re-send count for ARQ (Automatic Repeat Request) operation.RSSIDetails Page 38 Received signal strength indicator (in dBm). Unavailable at Master unless SETUP is enabled.RTUDetails Page 39 RTU simulator’s operational status (ON/OFF)RXTOTDetails Page 40 The amount of time (in seconds) to wait before issuing a time-out alarm. SAFDetails Page 40 Store-and-forward mode status in this unit. (ON/OFF)SERDetails Page 40 Serial number of radioSHOW CONDetails Page 41 Display virtual modem connection statusSHOW PWRDetails Page 41 RF output power. Measured RF power in dBm.SHOW SYNCDetails Page 41 Information on synchronization sourceSKIPDetails Page 41 Frequency zones that are skippedSLEEPDetails Page 42 Radio’s Sleep Mode setting. (At Remotes Only)SREVDetails Page 42 Transceiver firmware revision levelSTATDetails Page 43 Current alarm statusTEMPDetails Page 43 Transceiver’s internal temperature (°C)UNITDetails Page 43 Programmed unit address for network-wide diagnosticsXADDRDetails Page 44 This unit’s Extended addressTable 10. Operating Status—Display Only (Continued)Command Description
28 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D   6.3 Detailed Command DescriptionsThe essential commands for most applications are Network Address (ADDR), Mode (MODE), and Baud Rate (BAUD). However, proper use of the additional commands allows you to tailor the transceiver for a specific use, or to conduct basic diagnostics on the radio. This section gives more detailed information for the commands listed above in Section 6.2.Most of the commands below can be used in two ways. First, you can type only the command name (for example, ADDR) to view the currently programmed data. Second, you can set or change the existing data by typing the command, followed by a space, and then the desired entry (for example, ADDR 1234). In the descriptions which follow, allowable programming vari-ables, if any, are shown in brackets [  ] following the command name.XPRIDetails Page 44 Address of the primary Extended radio unit (Extension).XMAPDetails Page 44 Included Extended units in MODE X. (Extensions and Remotes only). XRSSIDetails Page 44 Minimum RSSI level required to preserve synchronization with a non-primary radio. (Only meaningful when XPRI is not NONE)Table 11. Diagnostic and Test Functions  Command DescriptionKEYDetails Page 35 Enables the transmitter test. (Must be in Setup mode. Details on page 40.)DKEYDetails Page 33 Turns off the transmitter test. (Must be in Setup mode. Details on page 40.)TX [xxxx]Details Page 43 Set/display transmit test frequency. (Must be in Setup mode. Details on page 40.)RX [xxxx]Details Page 39 Set/display receive test frequency. (Must be in Setup mode. Details on page 40.)SETUPDetails Page 40 Enables Setup mode. Times out after 10 minutes. Press “Q” to quit.ZONE DATADetails Page 44 Zone data statisticsZONE CLEARDetails Page 44 Clears the Zone Data logTable 10. Operating Status—Display Only (Continued)Command Description
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 29ADDR [1–65000]Network AddressThis command sets or displays the radio’s network address. The network address can range from 1 to 65000.A network address must be programmed at the time of installation and must be common across each radio in a given network. Radios are typically shipped with the network address unprogrammed, causing the address to display as NONE. If the address is not set (or is set to a wrong value) it leaves the system in an invalid state, preventing operation and generating an alarm.NOTE:  It is recommended that the last four digits of the Master radio’s serial number be used for the network address. This helps avoid conflicts with other users.AMASK [0000 0000–FFFF FFFF]Alarm MaskThis command sets the alarm bits that cause the alarm output signal to be trig-gered. The PWR LED will still flash for all alarms, but the alarm output signal will only be activated for those alarms that have the corresponding mask bit set. The hex value for the mask aligns directly with the hex value for the ALARM command. The default is FFFF FFFF. Through proper use of the AMASK command, it is possible to tailor the alarm response of the radio. Contact the factory for more information on configuring the alarm mask.AT [ON, OFF]Hayes-Compatible AT Command SupportAT-style modem commands, also know as “Hayes-Compatible Commands”, can be processed through the payload port. By setting AT ON at the Master (MODE M), individual Remotes can be accessed by using ATDT [Unit Address]. In this mode, RTUs designed only for dial-up access can be accessed through the Master station. For more details, see See “Using AT Commands” on Page 55 and “OT [ON, OFF]”  on Page 37.ASENSE [HI/LO]Alarm Output SenseThis command is used to set the sense of the alarm output at Pin 6 of the DATA connector. The default is HI which means an alarm is present when an RS-232 high is on Pin 6.BAUD [xxxxx abc]Data Interface Port Baud RateThis command sets or displays the communication attributes for the normal payload communications through the DATA port. The command has no effect on the RJ-11 DIAG(NOSTICS) port.
30 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D The first parameter (xxxxx) is baud rate. Baud rate is specified in bits-per-second and must be one of the following speeds: 300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600, or 115200. At baud rates of 19200 bps or less, the radio can support unlimited continuous data transmis-sion at any hop rate.The second parameter of the BAUD command (abc) is a 3-character block indicating how the data is encoded. The following is a breakdown of each character’s meaning:a = Data bits (7 or 8)b = Parity (N for None, O for Odd, E for Even)c = Stop bits (1 or 2)The factory default setting is 9600 baud, 8 data bits, no parity, 1 stop bit (Example: 9600 8N1).NOTE:  7N1, 8O2, and 8E2 are invalid communication settings and are not supported by the transceiver.BAND [A, B, C]Select Sub-Band (Normally used for 2.4 GHz model)This command sets or displays the receiving and transmit operating band for the radio.A = 2.4016–2.4270 GHzB = 2.4272–2.4526 GHzC = 2.4528–2.478.2 GHzNOTE: The same BAND must be programmed at the time of installation and must be common across each radio in a given network. BUFF [ON, OFF]Data Buffer ModeThis command sets or displays the received data handling mode of the radio. The command parameter is either ON or OFF. (The default is OFF.) The setting of this parameter affects the timing of received data sent out the DATA connector. Data transmitted over the air is unaffected by the BUFF setting.If data buffering is set to OFF, the radio will operate with the lowest possible average latency. Data bytes are sent out the DATA port as soon as an incoming RF data frame is processed. Average and typical latency will both be below 10 ms, but idle character gaps may be introduced into the outgoing data flow.If data buffering is ON, the radio will operate in a seamless mode. That is, data bytes will be sent over the air as quickly as possible, but the receiver will buffer the data until the entire packet has been collected. The delay introduced by data buffering is variable and depends on message size and the number of retransmissions required, but the radio will not create any gaps in the output data stream. This mode of operation is required for protocols such as MODBUS™ that do not allow gaps in their data transmission.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 31Seamless mode (BUFF ON) is intended only for applications where the message size is 256 characters or less. Enforcement of this rule is left up to the user. If more than 256 characters are transmitted data delivery will not be seamless and data may be lost.Changes to the BUFF setting may only be made at the Master radio. This is because the Master radio broadcasts the buffer setting for the entire network. At Remote radios, the buffer setting may be read when the radio is in synchro-nization with the Master, but it cannot be changed.CODE [NONE, 1…255]Security CodeThe CODE command is used to select or display the security/encryption setting in the radio.The default is CODE NONE. Setting CODE to a value other than NONE provides an extra level of security beyond that provided by the Network Address (ADDR). The disadvantage is increased complexity in managing the network. The CODE command takes an argument 1…255, or NONE. Entering CODE without an argument will display either NONE or ACTIVE. ACTIVE means that security/encryption has been enabled, but the radio will not display the security argument.When a CODE value is active, all radios in the system must use the same code value. If the code value is not properly programmed, a Remote radio will not synchronize with the Master.CAUTION: Record the CODE value and store it in a safe place. If the code is later forgotten, and a unit is to be added to the system, all radios in the network must be set to NONE and then reprogrammed to a new value.CSADDR [1–65000, NONE]Clock-Synchronizing Master AddressUsed to specify the network address of a “Clock-Sync” Master station to which this station will be synchronized. Also see “ADDR [1–65000]”  on Page 29 and “Co-Located and Close-Proximity Masters”  on Page 63 for further details.CTS [0–255]Clear-to-Send DelayThe CTS (clear-to-send) command sets or displays the timer value associated with the CTS line response. The command parameter ranges from 0 to 255 milliseconds.For DCE operation, the timer specifies how long to wait after the RTS line goes high before asserting the CTS line. A timer value of zero means that the CTS line will be asserted immediately following the assertion of RTS.
32 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D For CTS Key operation (see the DEVICE command), the timer specifies how long to wait after asserting the CTS line before sending data out the DATA port. A timer value of zero means that data will be sent out the data port without imposing a key-up delay. (Other delays may be in effect from other radio operating parameters.)CTSHOLD [0–60000]Clear-to-Send Hold TimeUsed in DEVICE CTS KEY mode, this command sets the amount of time in milliseconds that CTS remains present following transmission of the last character out the RXD pin of the DATA port. This “hold time” can be used to prevent squelch tail data corruption when communicating with other radios.The CTSHOLD setting can range from 0 to 60000 (i.e., 60 seconds). The default value is 0, which means that CTS will drop immediately after the last character is transmitted. If the command is entered when the radio is in DEVICE DCE mode, the response CTSHOLD N/A will be displayed.DEVICE [DCE, CTS  KEY]Radio-MODEM BehaviorThe DEVICE command sets or displays the device behavior of the radio. The command parameter is either DCE or CTS KEY.The default selection is DCE. In this mode, CTS will go high following RTS, subject to the CTS programmable delay time. Keying is stimulated by the input of characters at the data port. Hardware flow control is implemented by dropping the CTS line if data arrives faster than it can be transmitted.If CTS KEY is selected, the radio is assumed to be controlling another radio, such as in a repeater or tail-end link system. The RTS line is ignored and the CTS line is used as a keyline control for the other radio. CTS is asserted immediately after the receipt of RF data, but data will not be sent out the DATA port until after the CTS programmable delay time has expired. (This gives the other radio time to key.)Following transmission of the last byte of data, CTS will remain asserted for the duration specified by the CTSHOLD command. CTSHOLD should be set sufficiently high.DLINK [xxxxx/ON/OFF]InSite Diagnostics Link SupportDLINK ON enables use of Diagnostic Link mode and establishes it as the default protocol on the RJ-11 DIAG port. Diagnostic Link mode is a special protocol used to support Network-Wide Diagnostics. DLINK must be set to ON to support connection to InSite or to support chained diagnostics between radio networks even while the radio is in sleep mode. DLINK OFF disables this feature. The default setting is ON.The following DLINK baud rates selections are supported:• 1200 • 4800 • 9600 • 19200 (default)
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 33• 38400 • 57600 • 115200Example: DLINK 4800 sets the RJ-11 DIAG port to operate at 4800 bps when diagnostics is closed. This setting will not affect the port’s autobaud opera-tion. Use only of DLINK ON, will enable the use 19200 or the most recently programmed value. The default is DLINK 19200 and DLINK ON. NOTE 1:  The same baud rate must be entered into the InSite Equipment List’s BAUD field.NOTE 2:  The DLINK rate must match the rate of any connected device to the diagnos-tic port. This may be either another MDS radio’s diagnostic port, InSite com-puter, or another data link device that eventually connects to the InSite computer.DKEYTurn Off Radio Transmitter ‘s Test SignalDisables the transmitter when it is keyed. See also KEY command.DTYPE [NODE/ROOT]Network Diagnostics ModeThe DTYPE command specifies the radio’s operational characteristics for network-wide diagnostics. The transceiver uses the following types:•NODE—The most common setting, and the default. This is the basic system radio device-type. Typically, the radio network is comprised of nodes and one root. Intrusive diagnostics can originate from any node. However, non-intrusive diagnostics can only be conducted from the root node.•ROOT—Always one, and only one, per network (including units associated through Extension units.) The root is the focal point of network-wide diagnostics information. Intrusive diagnostics can originate from any radio, including the root. However, the root is the only radio through which non-intrusive diagnostics can be conducted.FEC [ON, OFF]Forward Error CorrectionThis command is used to view the FEC setting, or turn it on or off. The default setting is FEC ON. (It needs to be turned off when throughputs exceed 57,600 bps.) FEC is set at the Master and is automatically passed on to all Remotes in a network.Setting FEC to ON improves sensitivity at the cost of reduced throughput. Typical SCADA/telemetry applications use low data rates and, as such, the FEC setting is normally transparent to them.
34 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D HOPTIME [7, 14, 28]Radio Transmitter Hop TimingThe HOPTIME command is used to set or display the hop-time setting. The command is a digit corresponding to the hop-time setting in milliseconds. The default HOPTIME setting is 7. A setting of 28 must be used when throughputs exceed 57,600 bps and is recommended when data transmission sizes exceed 256 bytes.Changes to the HOPTIME setting may only be made at the Master radio. (This is because the Master radio establishes the hop-time setting for the entire network.) At Remote radios, the hop-time setting may be read when the radio is in synchronization with the Master, but it cannot be changed.INITInitialize; Restore to Factory DefaultsThe INIT command is used to reset the radio’s operating parameters to the factory defaults listed in Table 12 on Page 34. This may be helpful when trying to resolve configuration problems that resulted from the entry of one or more improper command settings. If you are unsure of which command setting caused the problem, this command allows you to get back to a known working state.NOTE:  Caution should be exercised when using the INIT command on radios in a sys-tem employing the Store-and-Forward feature. Settings relating to the use of Ex-tension services will be lost and will need to be re-entered. Record the settings for XADDR, XPRI and XMAP before using the INIT command.SPECIAL NOTE:  Installing firmware of Revision 3.0 or later into a radio with Revisions 1.x firm-ware will preserve the radio’s compatibility with other radios running Revision 1.x firmware. If updating the radio’s firmware is part of a system-wide upgrade, the last step should be to use the INIT command at the Master station. Use of the INIT command causes the changes shown in Table 12 to be applied.Table 12. INIT Command Generated Defaults  Parameter Default SettingCorresponding CommandFor ALL radiosAlarm Mask FFFF FFFF AMASKAlarm Output Sense RS-232 High (+5.0 Vdc) ASENSEDevice Operation DCE DEVICE DCEDATA Interface Port • 9600 baud• 8 data bits• none (no parity)• 1 stop bitBAUD 9600 8N1Data Port Setting RS/EIA-232 PORT RS232CTS Delay 0 (CTS is continuously asserted) CTS 0CTS Hold-Time 0CTSHOLD 0
35 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D HREVHardware RevisionShows the hardware revision of the radio.KEYTurn On Radio Transmitter Test SignalEnables the transmitter. (Radio must be in Setup mode.) See also DKEY command (DKEY Details, page 33).LED Operation OFF LEDLow-Power Mode Hold 0LPMHOLDRX Time-Out-Timer None/Disable RXTOTRF Output Power 30 dBm (1 watt) PWR 30TransmitterTest Frequency 915.000 MHz or2436.0 MHz(Model dependent)TX xxxReceiverTest Frequency 915.000 MHz2436.0 MHz(Model-dependent)RX xxxSleep Mode OFF SLEEP OFFPrimary Extension Radio Address 0 (Master) XPRI 0Synchronization Source Map None XMAP 0Extended Address 0XADDR 0For MASTER radiosAT Command Support OFF  ATBuffer Mode OFF  BUFF OFFForward Error Correction ON FEC ONHop-Time 7 ms HOPTIME 7Low-Power Mode 0 (Off) LPMSkipped Frequencies None (radio will hop across all frequencies) SKIP NONERetry Count 10 (max. of 10 repeats for ARQ) RETRY 10Repeat Count 3 (downstream repeats) REPEAT 3Table 12. INIT Command Generated Defaults  (Continued)Parameter Default SettingCorresponding Command
36 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D LED [ON, OFF]Enable/Disable PCB LEDsLED ON enables/disables the PCB board mounted LEDs seen only with the transceiver’s covers removed. LED is normally OFF, it may be useful to have them on for testing the radio with the covers removed. Note: the external LEDs will be dimmer if the LED function is left ON.The LED command also affects the operation of the LEDs in the “Low-Power Mode” (LPM). When LED is OFF, the radio keeps the PWR and SYNC LEDs extinguished.LPM [1, 0]Low-Power Mode—Masters OnlyThis feature trades increased latency to gain power savings. Low-power mode (LPM) automatically saves power at a Remote by instructing the Remote to shutdown for large periods of time in between SYNC messages. Master transmissions are automatically blocked while the Remotes are asleep. Note, both Masters and Remotes are adaptive and will suppress a normal sleep interval if data transmission or reception is in progress.•LPM 1 at the Master enables low-power mode network-wide; all Remotes pick it up and start saving power by automatically sleeping.LPM 1 can work in conjunction with the AT dialing feature. The dialed unit will be forced awake; all others will sleep.•LPM 0 at the Master to disable low-power mode (Default setting).The SLEEP command must be enabled for LPM to function. Further, when you enable LPM, the LEDs on the Remote radio dim even though the LPM function is not properly enabled by turning on SLEEP. For more information, see “Low-Power Mode (LPM)—Master Enabled”  on Page 60, and “Low-Power Mode versus Remote’s Sleep Mode”  on Page 62.LPMHOLD [0–1000]Low-Power Mode Sleep TimeUsed to give an RTU time (0-1000 ms) to respond before the radio goes to sleep. Value determines how long to suppress auto-sleep following reception of the last character sent out of the RXD serial data port.NOTE:  Any values entered will be rounded to the nearest multiple of 4 ms.To verify the exact hold time, enter LPMHOLD, the response will give you the value currently being used.MODE [M, R, X]Radio Operating ModeThe MODE command sets or displays the operating mode of the radio. A Master radio is set by MODE M; a Remote set by MODE R, and an Extension is set by MODE X.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 37All units default to Remotes; other modes must be specifically programmed with the MODE command.If MODE X is used, the MODE X radio should be programmed with an Extended Address (XADDR). Units that need to hear this MODE X radio must be programmed with an appropriate XPRI and/or XMAP value.MRSSI [NONE, –40...–90]Minimum RSSI for Mobile OperationThe MRRSSI command sets or displays the minimum RSSI level (dBm) of a Master station’s signal to maintain synchronization. When the Master’s signal falls below this level, the Remote will attempt to resynchronize with the next Master it can hear within the same network—same Network Address (ADDR)—and, meets the MRSSI level. See “Mobile Operation Support” on Page 62 for additional information.OT [ON, OFF]Output TriggerThe “output trigger” feature sets up a 1-second default delay on delivery of RXD serial data, however, a receipt of RTS causes cancellation of timer followed by immediate data delivery.Hierarchy Rules:• if OT  = ON, RTS always cancels data delay and outputs immediately• if OT = ON, DEVICE = DCE, and RXD = 0, data delay is 1 second or until RTS• if DEVICE = DCE, and RXD = N, data delay is N ms• if DEVICE = CTS KEY, and CTS = N, data delay is N ms or until RTS• if DEVICE = CTS KEY overrides RXD, RXD overrides OT default.OWM [xxxxx]“Owner’s Message”The OWM command sets or displays an optional owner’s message, such as the system name. The entry can contain up to 30 characters.OWN [xxxxx] “Owner’s Name”The OWN command sets or displays an optional owner’s name, such as the site name. The entry can contain up to 30 characters.PORT [RS232, RS485]Data Interface Port Signaling StandardSelect or identify the current data port (DATA connector) interface signaling mode: RS232 or RS485. This is the port though which the payload data will
38 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D pass. Pin descriptions for EIA-232 are on page 69 and EIA-485 can be found on page 71. PWR [20–30]Radio Transmitter Power LevelThis command displays or sets the desired RF power output of the radio. The PWR command parameter is specified in dBm and can be adjusted in 1 dBm steps. The default setting is 30 dBm (1 watt) for the 900 MHz model and 27 dBm (0.5 watt) for the 2400 MHz model. To read the actual (measured) power output of the radio, use the SHOW PWR command.In the USA, maximum allowable power is governed by FCC limits on Effec-tive Isotropic Radiated Power output (EIRP). The EIRP limit of +36 dBm on the 900 and 2400 MHz band, means that any user with a net antenna gain greater than 6 dBi on the 900 MHz band, or 9 dBi on the 2400 MHz band, must decrease the PWR setting accordingly. “How Much Output Power Can be Used?”  on Page 12 contains a detailed discussion of this topic.REPEAT [0–10]Downstream Repeat Transmission CountThe REPEAT command affects “downstream” data. The command causes a Master or Extension to always repeat transmissions for the specified number of times (range is 0 to 10; default selection is 3). Unlike the RETRY command, there is no acknowledgment that a message has been received.Use the REPEAT command without a value to display the current setting.RETRY [0–10]Upstream Repeat Transmission CountThe RETRY command affects upstream data. The command selects, or displays, the maximum number of times (0 to 10) that a Remote radio will re-transmit data. The default setting is 10.This command is associated with ARQ (Automatic Repeat Request) opera-tion of the radio and is intended for use in areas with heavy radio interference.When the RETRY command is issued without parameters, the maximum retransmission count is shown. A value of 0 represents no retries, while values of 1 or greater successively improve the chance of data delivery in spectrally harsh environments (at the expense of possibly increased latency). The RETRY value is only setable at the Master. It is readable by a synchro-nized Remote.RSSIReceived Signal Strength IndicatorThis command displays the radio’s Received Signal Strength Indication in dBm (decibels relative to 1 mW). The output can range from –40 dBm to –120 dBm. Command availability and results depend on the mode of opera-tion (Master or Remote). The closer to 0 dBm, the stronger the signal, thus a reading of –70 dBm is stronger than –80 dBm.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 39For a Remote radio, under normal operation, RSSI is based on the average signal strength of the SYNC message received in each of the eight frequency zones. (RSSI is sampled each time a SYNC message is received.) When using the RSSI reading to align a directional antenna, it is important to make changes slowly so that the RSSI reading will provide meaningful results. It will take several seconds to indicate a change in signal level. The radio stays in RSSI mode until   is pressed.For a Master radio, under normal operation, entering the RSSI command causes the response NOT AVAILABLE to be returned. This is because a Master is normally receiving signals from several Remote stations and an RSSI reading would be continually changing. The only exception is when the SETUP command has been asserted. This disables hopping and allows reading a “raw” RSSI signal level in real time from a Master or Remote radio.NOTE 1: RSSI readings will not accurately indicate signals stronger than –40 dBm.NOTE 2: RSSI works for Dependent Masters. Command displays “NOT AVAILABLE” if the Dependent Master is not synchronized.RTU [ON, OFF, 0-80]Remote Terminal Unit SimulatorThis command re-enables or disables the radio’s internal RTU simulator, which runs with MDS’ proprietary polling programs (poll.exe and rsim.exe). The internal RTU simulator is available whenever a radio has diagnostics enabled. This command also sets the RTU address to which the radio will respond.The internal RTU can be used for testing system payload data or pseudo bit error rate (BER) testing. It can be helpful in isolating a problem to either the external RTU or the radio. The default RTU setting is OFF.RX [xxxx]Radio Receive Test FrequencyThis command sets or displays the test receive frequency used in place of hopping when the radio is in SETUP mode. The test receive frequency can be reprogrammed to any value between 902.200 MHz and 927.800 MHz, inclu-sive. The factory default setting is 915.000 MHz.RXD [0–235] / [ON/OFF]RXD DelayUsed to set a delay, in milliseconds, of RXD data to emulate a seamless mode with much lower latency in applications where retries are not required. Use a delay of twice the value of the HOPTIME period (See page 34).Entering a RXD ON (0 ms default) or RXD XX will enable the function. Entering RXD OFF will disable the function and erase any stored value.ENTER
40 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D RXTOT [NONE, 0–1440]Receive Data Timeout-TimerThis command sets or displays the amount of time (in minutes) to wait for the next received data packet before issuing a receiver time-out alarm. The default setting is NONE.SAF [ON, OFF]Store-and-Forward Services SupportThis command enables/disables the operation of the Store-and-Forward services. It can be set only at the network’s Master station, but will effect all radios in the associated network. The default setting is OFF. See related commands: “XADDR [0–31]”  on Page 44, “XPRI [0–31]”  on Page 44, and “XMAP [00000000-FFFFFFFF]”  on Page 44.SETUPSetup Radio TestThis command sets up the transceiver for checking antenna SWR or trans-mitter power with external measuring equipment. Do not use this mode during normal operation.When the SETUP command is entered, the prompt changes to SETUP>, and:• Hopping is disabled.•Synthesizer frequencies are reset to the test frequencies specified by the TX and RX commands described earlier.•The radio can be keyed using the KEY command. DKEY is used to unkey the radio. (If the radio is left in a keyed state it is automatically unkeyed after 10 minutes.)• The RSSI is sampled in a raw, continuous fashion regardless of whether the unit is a Master or a Remote.Entering Q or QUIT returns the system to normal operation.A timer keeps the Setup mode from accidentally leaving the system disabled. After 10 minutes the system behaves as if Q or QUIT had been entered, returning the unit to normal operation.NOTE:  TransNET uses a automatic level control in normal operation to keep transmit power constant over time. This facility is disabled in Setup mode. To test 1 Watt power output in Setup mode, the user must enter PWR 30 followed by KEY. The power output will only be valid for the first couple of seconds. SERRadio Serial NumberDisplays the serial number of the radio.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 41SHOW CONShow Virtual Connection StatusShows virtual connection status established by the latest ATDT command sequence. (Works only with AT ON. See“AT [ON, OFF]”  on Page 29)If no connection is established, it displays NONE.If a connection is active, it will display:<Master unit address> TO <Remote (“dialed”) unit address>.SHOW PWRShow Measured RF Transmit PowerThe SHOW PWR command displays the actual (measured) RF power output in dBm. Unlike the PWR command, this command shows the actual level being measured, not the programmed RF power setting.SHOW SYNCShow Clock-Synchronization Master Network AddressWhen used at a Remote station, this command will display Extended Address and Unit Address of the Master or Extension radio to which the Remote is synchronized. The network depth at the Remote, defined as the number of downstream links from the Master, is displayed in parentheses.SHOW SYNC works for Dependent Masters. A value of zero (0) means the station is a Master synchronized to a Clock-Sync Master. The SHOW SYNC command will display an asterisk (*) after depth value if the radio is operating with co-located Masters.SKIP [NONE, 1...8]Skip Radio Operating ZonesThis command sets or displays which, if any, of the eight zones will be skipped from the radio’s hopping sequence. Skipping zones is one way of dealing with constant interference on one or more frequencies in the radio’s operating band. See “A Word About Radio Interference” on Page 8 for more information on dealing with interference.Tables 13, 14, 15 and 16 show the frequency range covered by each zone. The command parameter is either the keyword NONE or an undelimited string of up to four digits where each digit 1...8 represents a corresponding zone to skip. (For zone parameter input, the digits can appear in any order and can be optionally separated by a blank space.) The SKIP command is display-only at Remote radios. (Remotes must be synchronized with the Master radio to display the skip status.)
42 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D In the USA, a maximum of four zones may be skipped for TransNET 900 and a maximum of three zones may skipped for TransNET 2400. Check the regu-latory requirements for your region. The SKIP function may not be permitted in your country and the radio will not respond to the SKIP command.   SLEEP [ON, OFF]Transceiver Sleep—Remotes OnlyThis command is used to set or display the radio’s Sleep Mode setting. The default setting is SLEEP OFF. When this setting is ON (enabled) the Low-Power, or RTU-forced Sleep Mode, can be used. This function cannot be turned on for a Master or Extension radio unless the unit is in the Low-Power Mode. See “Using the Radio’s Sleep Mode (Remote Units Only)”  on Page 59 and “Low-Power Mode versus Remote’s Sleep Mode”  on Page 62 for more information.SREVFirmware Revision LevelThis command displays the version of the firmware currently loaded into the transceiver.Table 13. 900 MHz Frequency Skip ZonesZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8902.2to905.2905.4to908.4908.6to911.6911.8to914.8915.0to918.0918.2to921.2921.4to924.4924.6to927.6Table 14. 2400 MHz, Band A, Frequency Skip ZonesZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 82401.6to2404.62404.8to2407.82408.0to2411.02411.2to2414.22414.4to2417.2417.6to2420.62420.8to2423.82424.0to2427.0Table 15. 2400 MHz, Band B, Frequency Skip ZonesZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 82427.2to2430.22430.4to2433.42433.6to2436.62436.80to2439.82440.0to2443.02443.2to2446.22446.4to2449.42449.6to2452.6Table 16. 2400 MHz, Band C, Frequency Skip ZonesZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 82452.8to2455.82456.0to2459.02459.2to2462.22462.4to2465.42465.6to2468.62468.8to2471.82472.0to2475.02475.2to2478.2
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 43A display of 06-4040A01, 3.6.1 is an example of the firmware version identi-fier—part number followed by release/version number.STATAlarm StatusThis command is used to check the alarm status of the radio. If no alarms exist, the message NO ALARMS PRESENT is returned.If an alarm does exist, a two-digit alarm code (00–31) is displayed and the event is identified as a “Major” or “Minor” alarm. A brief description of the event is also given.If more than one alarm exists, the word MORE appears, and additional alarms may be viewed by pressing the   key. Detailed descriptions of the alarm codes are provided in Table 18 on Page 47.TEMPRadio’s Internal TemperatureThis command displays the internal temperature of the transceiver in degrees Celsius. (Note that the radio is specified to operate in an environment between –30° C and +60° C). This internal reading may be higher than the outside temperature by several degrees.TX [xxxx]Radio Transmit Test FrequencyThis command sets or displays the test transmit frequency used in place of hopping whenever the radio is in Setup mode. The test transmit frequency for the 900 MHz radios can be reprogrammed to any value between 902.200 MHz and 927.800 MHz, inclusive. The factory default setting is 915.000 MHz. For the 2400 MHz radios, the test frequency can be programmed to any frequency between 2400.6 MHz and 2482.0 MHz. The default value is 2436.0 MHz.UNIT [10000–65000]Unit AddressThis command sets the unit addressing for network-wide diagnostics and AT-Command address. The unit address is factory programmed to the last four digits of the radio’s serial number. If re-programmed in the field, the entry must consist of five digits between 10000 and 65000.ENTER
44 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D XADDR [0–31]Extended AddressUsed to display or program the Extended Address of this radio that will serve as a common address for the sub-network synchronized to this Master or Extension. This value can be listed in the XPRI parameter of associated Exten-sion or Remote radios to allow them to synchronize to this radio. We recom-mend setting the Master to zero (0). It is easy to remember, and is the default address when the INIT command is used. (Programmed only in Master and Extension radios.)XMAP [00000000-FFFFFFFF]Map of Extension AddressesXMAP is a 32-bit hex entry where the least significant bit represents XADDR 0 and the most significant bit represents XADDR 31. The full 32-bit hex value represents the entire list of extensions with which the radio will be allowed to communicate. (Pertains to Remotes and Extensions only.)This parameter is easily programmed through the MDS TransNET Configu-ration Software’s Store-and-Forward Settings panel.XPRI [0–31]Primary Extended AddressWill display or program the extended address of the primary radio with which this radio will attempt to synchronize and communicate. A setting of NONE allows the unit to synchronize with any Master or Extension in the XMAP list. (Parameter only meaningful for Remote or Extension units.)XRSSI [NONE, –40...–120]Extension RSSI LevelThe XRSSI command is used to set the RSSI minimum signal level required to preserve synchronization with a non-primary Extension radio. This param-eter will be ignored if XPRI is set to NONE.ZONE CLEARClear Zone Statistics LogThe ZONE CLEAR command clears the zone data for all zones in the Zone Data Log, resetting the count to 0. (Zone data is also cleared automatically upon reboot.)ZONE DATARead Zone Statistics LogThe transceiver divides its frequency operating spectrum into eight 3.0 MHz-wide zones or sub-bands. (These are the same zones referenced by the SKIP command described earlier.) Data frame statistics are maintained for each zone to indicate the transmission quality of data through the network. This information is useful for identifying zones where significant interference exists.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 45Historical information on the quality of each zone can be accessed using the ZONE DATA command. The report shows you the number of data frames sent, the number received, and the number received with errors. If an excessive number of errors are seen in one or more frequency zones, it may indicate interference, and you should consider “skipping” those zones using the SKIP command (See “SKIP [NONE, 1...8]” on Page 41).Note: If a frequency zone has been skipped, all counts for that zone will be zeros.The ZONE DATA format is displayed as follows:1:TX TOTAL 000000001:RX TOTAL 000000001:RX ERROR 00000000x:x:x:8:TX TOTAL 000000008:RX TOTAL 000000008:RX ERROR 00000000All data is based on payload packets. Incoming network data may be divided into multiple packets for over-the-air transfers. The number before the colon represents the zone. TX TOTAL is the transmit packet total. RX TOTAL is the receive packet total. RX ERROR is the total number of received packets with CRC errors. All zone data is reset with the ZONE CLEAR command.7.0 TROUBLESHOOTINGSuccessful troubleshooting of an MDS transceiver system is not difficult, but requires a logical approach. It is best to begin troubleshooting at the Master station, as the rest of the system depends on the Master for polling instruc-tions and synchronization data. If the Master station has problems, the oper-ation of the entire network will be affected.When communication problems are found, it is good practice to begin by checking the basics. All radios in the network must meet these basic require-ments:• Adequate and stable primary power• An efficient and properly aligned antenna system• Secure connections (RF, data & power)• Proper programming of the radio’s operating parameters, especially Operating Mode (MODE), Network Address (ADDR), and interface Baud Rate (BAUD). For TransNET 2400 check the sub-band (BAND).• The correct interface between the radio and the connected data equipment (proper cable wiring, data format and timing).• In store-and-forward systems there are several areas that should be checked or evaluated:•Look for duplicate XADDR values on MODE M and MODE X radios. Duplicates will cause failures unless the radios are too far apart to hear each other.
46 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D •Check for errors in the synchronization qualifiers, XPRI and XMAP, on corresponding Remote radios.•Verify SAF is enabled at the Master radio.7.1 LED IndicatorsThe LED status indicators are an important troubleshooting tool and should be checked whenever a problem is suspected. Table 17 describes the function of each status LED.7.2 Alarm CodesWhen an alarm condition exists, the transceiver creates an alarm code. These codes can be very helpful in resolving many system difficulties.Checking for Alarms—STAT commandTo check for the presence of alarms, enter STAT. If no alarms exist, the message NO ALARMS PRESENT appears at the top of the display.If an alarm does exist, a two-digit alarm code (00–31) is displayed, and it is identified as a major or minor alarm. A brief description of the alarm is also given. Alarm codes and their meanings are listed in Table 18.If more than one alarm exists, the word MORE appears at the bottom of the screen; additional alarms can be viewed by pressing  .Major Alarms versus Minor AlarmsMajor alarms report serious conditions that generally indicate a hardware failure, or other abnormal condition that will prevent (or seriously hamper) further operation of the transceiver.Table 17. LED indicator descriptionsName DescriptionPWR • Continuous—Power is applied to the radio; no problems detected• Flashing (5 times-per-second)—Fault indication. See “TROUBLE-SHOOTING”  on Page 45.• Off—Radio is unpowered or in Sleep modeSYNC Continuous—Radio is receiving/sending synchronization framesOn within 10 seconds of power-up under normal conditionsTXD Transmit data activity on the DB-9 DATA interface connectorRXD Receive data activity on the DB-9 DATA interface connectorPWR SYNC TXD RXDENTER
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 47With the exception of alarm code 00 (network address not programmed), major alarms generally indicate the need for factory repair. Contact MDS for further assistance.Minor alarms report conditions which, under most circumstances, will not prevent transceiver operation. This includes out-of-tolerance conditions, baud rate mismatches, etc. The cause of these alarms should be investigated and corrected to prevent system failure.Alarm Code DefinitionsTable 18 contains a listing of all event codes that may be reported by the transceiver. Additional alarm codes may be used in future firmware releases or are used by the factory.Table 18. Alarm Codes  Alarm CodeAlarm Type Description00 Major The network address is not programmed.01 Major Improper firmware detected for this radio model.04 Major One or more of the programmable synthesizer loops is reporting an out-of-lock condition.08 Major The system is reporting that it has not been calibrated. Factory calibration is required for proper radio operation.10 Major The DSP was unable to properly program the system to the ap-propriate defaults. A hardware problem may exist.12 Major Receiver time-out alarm.16 Minor The unit address is not programmed.17 Minor A data parity fault has been detected on the DATA connector. This usually indicates a parity setting mismatch between the ra-dio and the RTU.18 Minor A data framing error has been detected on the DATA connector. This may indicate a baud rate mismatch between the radio and the RTU.29 Minor RF output power fault detected. (Power differs by more than 2 dB from set level.) Often caused by high antenna system SWR. Check antenna, feedline and connectors.30 Minor The system is reporting an RSSI reading below –105 dBm. 31 Minor The transceiver’s internal temperature is approaching an out-of-tolerance condition. If the temperature drifts outside of the recommended operating range and the transceiver may fail.
48 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 7.3 Troubleshooting ChartTable 19 provides suggestions for resolving system difficulties that may be experienced in the radio system. If problems persist, contact the factory for further assistance. Refer to the inside back cover of this guide for contact information.Table 19. Troubleshooting Guide  Difficulty Recommended System ChecksUnit isinoperative. a.Check for the proper supply voltage at the power connector.b.The transceiver’s internal fuse may have opened. Refer to Sec-tion 7.5 below for replacement instructions.Interference is suspected. a.Verify that the system has a unique network address. Nearby systems with the same address will cause interference.b.Check for interference by locking out affected zone(s) using the SKIP command (Page 41).c.If omnidirectional antennas are used on Remote stations, con-sider changing to directional antennas. This will often limit inter-ference to and from other stations.No synchroniza-tion with Master, or poor overall performance.a.Check for secure interface connections at the radio and the connected device.b.Check the antenna, feedline and connectors. Reflected power should be less than 10% of the forward power reading (SWR ≈ 2:1 or lower).c.If the Remote radio is in synchronization, but performance is poor, check the received signal strength using the RSSI com-mand (Page 38). If RSSI is low, it may indicate antenna prob-lems, or misalignment of directional antenna headings.d.Verify proper programming of system parameters: mode, net-work address, data interface baud rate, transmitter power, CTS delay, etc. For store-and-forward applications, also verify the following: SAF is ON; extended address is properly pro-grammed at each extension; Remotes are using the proper val-ues for XPRI and XMAP.e.Check for alarms using the STAT command (Page 43)BER is too high. Data throughput is spotty.a.The RETRY and REPEAT commands may be increased to deal with interference, or decreased to increase throughput and reduce latency. b.Try turning on FEC. FEC on gives some coding gain, but comes at the cost of reduced throughput.Latency is too high. a.Reduce the REPEAT count.b.Turn BUFF OFF. BUFF ON ensures that no gaps occur in the data, but this comes at the cost of increased latency.c.Make sure HOPTIME is set to 7.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 497.4 Performing Network-Wide Remote DiagnosticsDiagnostics data from a Remote radio can be obtained by connecting a laptop or personal computer running MDS InSite diagnostics software (Version 6.6 or later) to any radio in the network.NOTE:  The diagnostics feature may not be available in all radios. The ability to query and configure a radio via Network-wide Diagnostics is based on the feature op-tions purchased in the radio being polled.If a PC is connected to any radio in the network, intrusive polling (polling which briefly interrupts payload data transmission) can be performed. To perform diagnostics without interrupting payload data transmission, connect the PC to a radio defined as the “root” radio. A radio is defined as a root radio using the DTYPE ROOT command locally, at the radio.A complete explanation of Remote diagnostics can be found in MDS’ Network-Wide Diagnostics System Handbook (MDS P/N 05-3467A01).1. Program one radio in the network as the root radio by entering the DTYPE ROOT command at the radio.2. At the root radio, use the DLINK ON and DLINK [baud rate] commands to configure the diagnostic link protocol on the RJ-11 port.3. Program all other radios in the network as nodes by entering the DTYPE NODE command at each radio.4. Use the DLINK ON and DLINK [baud rate] commands to configure the diagnostic link protocol on the RJ-11 port of each node radio.5. Connect a PC on which MDS InSite software is installed to the root radio, or to one of the nodes, at the radio’s diagnostics port.To connect a PC to the radio’s DIAG port, an RJ-11 to DB-9 adapter (MDS P/N 03-3246A01) is required. If desired, an adapter cable may be constructed from scratch, using the information shown in Figure 21 on Page 69.6. Launch the MDS InSite application at the PC. (Refer to the InSite user’s manual for details.)Table 20. Network-Wide Diagnostics CommandsCommand DescriptionDLINK [xxxxx/ON/OFF] Details, page 32 Set baud rate of diagnostics linkDTYPE [NODE/ROOT] Details, page 33 Set radio’s operational characteristics for net-work-wide diagnostics
50 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 7.5 Internal Fuse ReplacementThe radio is protected by an internal fuse. This fuse can be blown by an over-voltage transient or an internal failure. Follow the procedure below to remove and replace the fuse:1. Disconnect the primary power cable and all other connections to the unit.2. Place the radio on its back and remove the four Phillips screws at the corners of the bottom cover.3. Carefully separate the top and bottom covers. There is a flat ribbon cable between the top cover’s LED panel and the motherboard. You do not need to disconnect the ribbon cable.4. Locate the fuse holder assembly behind the power connector. (See Figure 16).5. Loosen the fuse from the holder using a very small flat-bladed screwdriver, then use a small pair of needle-nose pliers to pull the fuse straight up and out of the holder.6. Use an ohmmeter or other continuity tester to verify that the fuse is blown.7. Install a new fuse by reversing the process. Replacement fuse: Littelfuse #0454002; 452 Series, 2 Amp SMF Slo-Blo fuse (MDS Part No. 29-1784A03).8. Re-install the covers, interface cables and check the radio for proper operation.Invisible place holder Figure 16. Internal Fuse and Holder Assembly Location
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 518.0 RADIO FIRMWARE UPGRADESFrom time to time, Microwave Data Systems releases new firmware for its radio products. This file can be installed in existing radios to take advantage of engineering improvements or additional features.8.1 Obtaining New FirmwareThe latest firmware for each radio type may be obtained free from our Web site at:www.MicrowaveData.comRegistration is required to access the downloads area of the MDS Web site.Firmware is also available on disks from MDS that are bundled with an instal-lation utility (MDS Radio Software Upgrade (upgrade.exe)) for transferring the firmware file on the disk to the radio.Saving a Web-Site Firmware File Onto Your PCMDS firmware upgrades are distributed as a plain-text (ASCII) file with a “.S28” extension. Browse the MDS Web site to find the desired “.S28” file for your radio. When you have found your selection, use the right mouse button to select a path on your computer on which to save the file. (If this isn’t done, your browser may display the firmware file contents as text on the screen instead of downloading it to your local hard drive.) After the “.S28” file has been saved to your computer, you may use either MDS TransNET Configuration Software or MDS Radio Software Upgrade programs to install this firmware in your radios.8.2 Installing Firmware Into Your Radio1. Connect the PC to the radio’s DIAG port using an RJ-11 to DB-9 Adapter Cable (MDS Part No. 03-3246A01). If desired, a cable can be fabricated from the information shown in Figure 21 on Page 69. 2. Start the MDS TransNET Configuration Software. Open diagnostics port to the radio. The program will automatically read the radio’s profile.3. From the File menu, select Radio Firmware Upgrade and follow the prompts to install the new firmware into the radio. Do not press the Cancel button once the installation has started or it will leave the radio without any code. When the installation is complete, another radio may be connected to your PC and programmed.NOTE:  If a firmware installation fails, the radio is left unprogrammed and inoperative. This is indicated by the PWR LED flashing slowly (1 second on/1 second off). This condition is only likely to occur if there is a power failure to the computer or radio during the installation process. The installation should be attempted again.
52 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 9.0 OPERATING PRINCIPLES AND CONFIGURATION9.1 SAF Operation with Extension RadiosThe Store-and-Forward (SAF) capability operates by dividing a network into a vertical hierarchy of two or more sub-networks. (See Figure 5 on Page 4.) Adjacent sub-networks are connected via Extension radios operating in “MODE X” which move data from one sub-network to the next one.The Store-and-Forward implementation adheres to the general polling princi-ples used in most multiple-address systems (MAS). Polls originate from the Master station, broadcast to all radios within the network, and travel hierar-chically downward. All Remotes will hear the same message, but only one Remote will respond. Messages within a hierarchy only travel in one direc-tion at a time.Using SAF will cut the overall data throughput in half, however, multiple networks can be inter-connected with no additional loss in network throughput.Simple Extended SAF NetworkThe following example depicts a two-level network utilizing a single Master (M) and an Extension (X) radio. See Figure 17.Invisible place holderFigure 17. Simple Extended SAF NetworkNetworks: J and KIn this network, messages directed to Remotes in the “K” sub-network, will be relayed through Extension radio Xj,k to the K-Remotes. Any response from a Remote in sub-network “K” will pass back through Extension radio Xj,k to the Master Mj. Radios in sub-network “J” operate on the same set of frequencies and sub-network “K” but with a different radio-frequency hopping pattern.In the SAF operation, the Extension radios are set to MODE X (Details Page 36) and operate with a “dual personality”—50% of the time it serves as a Remote station and 50% of the time as a Master for sub-network Remotes.MJRJRJXJ,KRJRKRRKKSub-Network “J”Sub-Network “K”
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 53Extended SAF NetworkBelow is an example of a multilevel network utilizing two repeaters—XJ,K and XK,L. The example demonstrates the extensibility of the network. In this case, messages directed to Remotes in the sub-network L will be relayed through Extension radios XJ,K and XK,L. Like the previous example, the Extension radios will split their operating time equally between their Master and Remote “personalities.” This multi-layered network can be extended indefinitely without degradation in throughput, beyond that initially incurred by placing the network in the SAF mode.Invisible place holderFigure 18. Extended SAF NetworkNetworks: J, K, LRetransmission and ARQ OperationFunctionally, the sub-network side of an Extension behaves like a corre-sponding connection between a Master and a Remote. When an Extension is using its “Master personality” it sends acknowledg-ments and performs unconditional retransmissions based on its REPEAT count. When an Extension is using its “Remote personality,” acknowledgments are processed and retransmissions occur as needed, up to the number of times specified by the RETRY count value.If data arrives from a new source prior to completion of retransmissions, it is considered to be a violation of the polling model protocol. The new data takes precedence over the old data, and the old data is lost. In such a situation, new data is likely to be corrupted as it will have some old data mixed in with it.SAF Configuration ExampleHere is an outline for the configuration of a simple store-and-forward link.XK,LRLRLMJRJRJXJ,KIRJRKRKRLSub-Network “J”Sub-Network “K”Sub-Network “L”
54 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 1. Mode X and M Radios—Can have direct reports (Mode R radios) out-side of the chain.2. Data (Payload)—Travels from Master to Remote, and back from Remote to Master.3. Mode X and R Radios—Extension links can be protected by mapping one or more fall-back paths in case of a failure. Add secondary exten-sion addresses (XADDR) into the XMAP table. (See “XMAP [00000000-FFFFFFFF]”  on Page 44.) For example, as shown in Figure 19, Remote “D” could use Remote “C” as its extension primary, and Remote “B” (X ADDR = 1) as an alterna-tive in case of a failure of Remote “C” (X ADDR = 2). This arrangement assumes a serviceable path between Remotes “D” and “B”, and requires Remote “D” to be programmed with XMAP = 2 to correspond with the XADDR address of Remote “B.”Invisible place holderFigure 19. SAF Configuration ExampleThis configuration is easily arranged through the use of the Extension Map in the MDS TransNET Configuration Software’s “Store-and-For-ward Settings.”9.2 Synchronizing Network UnitsThe Master controls the synchronization for a given network for all modes. Setting the Master to SAF ON broadcasts a command from the Master to all radio units in the associated network either directly or through an Extension radio. This command puts all radios in the entire system in a special time-division duplexing mode that alternates between two timeslots. One time slot for data communications upstream and the second for downstream communications.The Extensions are single radios which serve as bridges between adjacent sub-network levels. Extensions will undertake a “Remote personality” in one timeslot, and a “Master personality” in the alternate timeslot and provide communications with associated Remotes downstream. Extensions behave like two radios with their data ports tied together, first synchronizing with their upstream Master during their Remote personality period, and then providing synchronization signals to dependent Remotes downstream during its Master personality period.ABCDEMODE = MADDR = 1234X ADDR = ØX PRI = NoneMODE = XADDR = 1234X ADDR = 1X PRI = ØMODE = XADDR = 1234X ADDR = 2X PRI = 1MODE = XADDR = 1234X ADDR = 3X PRI = 2XMAP = 2MODE = RADDR = 1234X ADDR = 4X PRI = 3TransNETRadios:RadioConfguration:
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 55All Remotes synchronize to a corresponding Master. This can be the “real Master” (the MODE M unit), or it can be a repeater “Extension” that derives synchronization from the “real Master.”Payload polls/packets broadcast from the network Master will be repeated to all levels of the network, either directly to Remotes, or through network repeaters—the Extension station. The targeted Remote responds to the poll following the same path back to the Master.Synchronization MessagesRemotes acquire synchronization and configuration information via SYNC messages. They can synchronize to the Master (the MODE M unit) or to any valid Extension (a MODE X unit). The Master will always transmit SYNC messages. An Extension will only start sending SYNC messages after synchronization is achieved with its Master.The ability to synchronize to a given radio is further qualified by the sender’s Extended Address (XADDR) and by the receiver’s Synchronization Qualifiers (XMAP, XPRI, and XRSSI).When a primary is specified (XPRI is 0...31), a radio will always attempt to find the primary first. If 30 seconds elapses and the primary is not found, then the radio attempts to synchronize with any non-primary radio in the XMAP list.Once every 30 minutes, if a primary is defined, the radio will check its synchronization source. If the radio is synchronized to a unit other than the primary, then the current RSSI value is compared to the XRSSI value. If RSSI is less than XRSSI (or if XRSSI is NONE) the radio will force a loss-of-synchronization, and hunt for the primary again (as described in the previous paragraph). By default, Extensions (and the Master) begin with XADDR 0. Synchroniza-tion qualifiers are set to XMAP 0, XPRI 0, and XRSSI NONE, respectively. This default configuration allows any radio to hear the Master. When an Extension is added, the extended address of the Extension radio must be set to a unique value. All Remotes that need to hear that extension can specify this either by designating the extension as the primary (XPRI), or by including it in their list of valid synchronization sources (XMAP).9.3 Using AT Commands A TransNET network may be configured to support protocols employing Hayes-Compatible modem commands through the radio’s AT Mode. In this mode, TransNET units can provide a communications replacement for dial-up modems where the RTUs and the protocol do not contain address-ability, and the establishment of a direct-communications link is the only way to determine if the RTU has data ready to be sent. This requirement is common in many older SCADA systems which were developed for direct
56 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D connections where wire lines were the only communications link available at the time. Most of these older system implemented support for the AT commands needed in the host software, so TransNET units can be used without software modifications.In this mode, the Master’s DATA port is parsed for a subset of AT commands. (See Supported Commands below). When an ATDTxxxxx data sequence is detected, and xxxxx is a unit address of a radio in the network, the TransNET Master will establish a virtual link to that unit. It will remain in that state until either another ATDTxxxxx or ATH (hang-up/disconnect) is detected. (Note: Unaddressed Remotes in the network will not respond to user data. Data will only be exchanged between the equipment connected to the addressed Remote unit and the network or device connected to the Master’s DATA port.In order to use this mode, the command AT ON must be selected at the Master Radio. The acknowledgment to an ATDT command is simulated by the Master; there is no true verification that the far-end connection is valid.Please consider the following additional information before using the AT commands:• Radio commands and AT commands are independent with unique syntax and functional objectives.•ATDT is not a radio command; it is part of the payload data input and follows the syntax for Hayes-compatible modems.•TransNET commands are entered through the RJ11 DIAGNOSTIC port on Master and Remote radios. AT ON and UNIT are examples of TransNET commands.•AT commands are only entered through the Master’s DB-9 DATA port, and only when the TransNET command AT ON has been previously issued. The radio supports a subset of the Hayes-compatible modem AT set. Each command is entered without spaces, and always begins with AT, and ends with a carriage return key press.Supported AT Commands Supported modem commands on the payload port are:AT <attention>Replies with OK (Code 0).ATDT[xxxxx] <dial>The command xxxxx represents 5-digit unit address with a leading zero (0) if applicable. This command replies with CONNECT (Code 1). Once connected, all characters are passed through until a +++ is seen.ATH <hang up> or +++This command replies with OK (Code 0) and deletes any virtual connection to the currently addressed Remote station.ATV[x] <change verbosity>x = 0, means use numeric messagesx = 1, means use text messages (Default)Replies with OK (Code 0)
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 57AT <command errors>Replies with ERROR (Code 4)Characters with <no AT command> Modem will echo characters in data stream but will be ignored until a second “AT” is seen at which time the modem closes the virtual connection.Operation Notes When AT Commands are ON• Radios will not poll with the embedded RTU simulator unless a connection is established.•Network-wide diagnostics are unaffected by the dialed unit connection status.• The use of the TransNET OT command (Output Trigger) can be of benefit in some configurations. See “OT [ON, OFF]” on Page 37 for configuration details.9.4 Configuration Parameters for Store-and-Forward ServicesThe installation and configuration of a radio network with an Extension using SAF is straightforward with only a few unique parameters that need to be considered and set at each unit.In every network there can be only one Master station. It will serve as the sole gateway to the outside world. The following three tables detail the parameters that will need to be set on each type of radio in the network. • Network Master Radio—Table 21 on Page 57• Extension Radio(s)—Table 22 on Page 58• Remote Radio(s)—Table 23 on Page 59 Table 21. Configuration Parameters for SAF ServicesNetwork Master Radio  Parameter Command DescriptionOperating Mode MODE MDetails Page 36 Sets the radio to serve as a Master.Network Address ADDRDetails Page 29 A number between 1 and 65,000 that will serve as a common network ad-dress.All radios in the network use the same number.
58 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Extended Address XADDRDetails Page 44 A number between 0 and 31 that will serve as a common address for radi-os that synchronize di-rectly to this Master.Typically, the Master is set to zero (0).Store-and-Forward Mode SAF ONDetails Page 40 Enables store-and-for-ward capability in the net-work.Table 22. Configuration Parameters for SAF ServicesExtension Radio(s)  Parameter Command DescriptionOperating Mode MODE XDetails Page 36 Sets the radio to serve as an Extension.Network Address ADDRDetails Page 29 A number between 1 and 65,000 that will serve as a common network address.All radios in the network use the same number.Extended Ad-dress XADDRDetails Page 44 A number between 0 and 31 that will serve as a common address for radios that syn-chronize directly to this Ex-tension radio serving as Master for associated sub-network units.Zero (0) is recommended for the Master station.Primary Extended Address XPRI Details Page 44 XADDR number of the pri-mary or preferred radio with which this radio will synchro-nize.Extension Map XMAPDetails Page 44 Lists all XADDR values with which this radio can syn-chronize, excluding the XPRI address.Extension Received Signal Strength IndicatorXRSSIDetails Page 44 The minimum RSSI level re-quired to preserve synchro-nization with a non-primary radio. (Ineffective when XPRI is NONE)Table 21. Configuration Parameters for SAF ServicesNetwork Master Radio  (Continued)Parameter Command Description
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 599.5 Using the Radio’s Sleep Mode (Remote Units Only)In some installations, such as at solar-powered sites, it may be necessary to keep Remote transceivers’ power consumption to an absolute minimum. This can be accomplished using the radio’s Sleep Mode feature. Power consump-tion in the sleep mode will be less at higher voltages and more at lower volt-ages. Power in the Sleep Mode at 13.6 Vdc is approximately 3 mA.Sleep Mode can be enabled under RTU control by asserting a ground (or EIA/RS-232 low) on Pin 4 of the radio’s DATA connector. All normal func-tions are suspended until it is awakened. The radio stays in Sleep Mode until a built-in five-minute timer “awakens” it for resynchronization, or the low is removed from Pin 4. When Pin 4 is opened (or an EIA/RS-232 high is asserted), the radio will be ready to receive data within 75 milliseconds or less. The radio can be awak-ened more often if desired, by your RTU. NOTE:  The SLEEP function must be set to ON; without this, a ground on Pin 4 will be ignored.Table 23. Configuration Parameters for SAF ServicesRemote Radio(s)Parameter Command DescriptionOperating Mode MODE RDetails Page 36 Sets the radio to serve as a Remote station.Network Address ADDRDetails Page 29 A number between 1 and 65,000 that will serve as a common network address or name.Same number for all units in the same net-work.Primary Extended Address XPRI Details Page 44 XADDR number of the primary or preferred radio with which this radio will synchronize.Extension Map XMAPDetails Page 44 Lists all XADDR val-ues with which this ra-dio can synchronize, excluding the XPRI address.Extension Received Signal Strength IndicatorXRSSIDetails Page 44 The minimum RSSI level required to pre-serve synchronization with a non-primary ra-dio. (Ineffective when XPRI is NONE)
60 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D It is important to note that power consumption will increase somewhat as communication from the Master station degrades. This is because the radio will spend a greater period of time “awake” looking for synchronization messages from the Master radio.In order for the radio to be controlled by Pin 4, the unit’s Sleep Mode must be enabled through the SLEEP [ON, OFF] command. See “SLEEP [ON, OFF]”  on Page 42 for more information.NOTE:  If INTRUSIVE polling is used in the MDS’ InSite NMS software, it is necessary to select SLEEP MODE INHIBIT ON from the Polling Options menu, on the Network Wide Diagnostic Polling screen.Sleep Mode ExampleThe following example describes Sleep Mode implementation in a typical system. Using this information, you should be able to configure a system that meets your own particular needs.Suppose you need communications to each Remote site only once per hour. Program the RTU to raise an EIA/RS-232 line once each hour (DTR for example) and wait for a poll and response before lowering it again. Connect this line to Pin 4 of the radio’s DATA connector. This will allow each RTU to be polled once per hour, with a dramatic reduction in power consumption.9.6 Low-Power Mode (LPM)—Master EnabledThe Low-Power Mode (LPM) puts Remote radios into a configuration similar to Sleep, but with some important distinctions. The most important difference is the radio will automatically go to sleep in this mode, regardless of the condition of Pin 4 of the DATA interface connector.This feature trades increased latency to gain power savings. The low-power mode (LPM) automatically saves power at a Remote by instructing the Remote to shutdown for long periods of time between SYNC messages. Master transmissions are automatically blocked while the Remotes are asleep. Note, both Masters and Remotes are adaptive and will suppress a normal sleep interval until after the end of a current data transmission or reception.Setup CommandsThese are the command options and their applications:•LPM 1 at the Master enables low-power mode network-wide; all Remotes pick it up and start saving power by automatically sleeping.LPM 1 can work in conjunction with the AT dialing feature. The dialed unit will be forced awake; all others will sleep.•LPM 0 at the Master is used to disable low-power mode (LPM)(Default setting following an INIT or firmware upgrade.)For LPMHOLD 0 with REPEAT 0 setting, a Remote with no data to send will consume about 1/4 of its normal power consumption. Note that the SLEEP command must be enabled for the LPM to function.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 61Reading RSSI and Other Parameters with LPM EnabledIt may be desired to perform tests and review operational settings of a Remote radio which has been programmed to operate in the low-power mode. Follow the abbreviated procedure below to interact with the radio through a local computer.• Disconnect the Remote’s antenna to force it to lose sync with the Master• Power-down the radio• Connect a computer running TransNET configuration software to the Remote’s DIAG(nostic) port.• Power-up the radio• Reconnect the antenna• Measure the RSSI or review and change any parameters you desirePower Consumption Influence by HOPTIME and SAF SettingsTable 24 presents representative current consumption and data delay values for various settings of TransNET radios setup for Low Power Mode, LPM (See “LPM [1, 0]” on Page 36). It assumes the primary power voltage is 13.8 Vdc and the polling rate is minimized to yield best-case power consump-tion (current) values.The more each RTU is polled and asked to transmit, the more current will be consumed. Therefore, these values are the lowest that can be expected. Power consumption (current) is inversely related to data delay as shown in the table. When a radio is sleeping (LPM) mode, it is also waiting longer to deliver the payload data.Note, the Store-and-Forward setting has a significant effect on power consumption, as it effectively doubles the HOPTIME to support LPM services. For the most power-efficient operation, turn on SAF even if you are not using repeaters.Table 24. Power Consumption versus Hoptime and SAF SettingsHOPTIME SAF Current (ma) Data Delay7 OFF 16 350 ms7ON10780 ms28 OFF 7 1620 ms28 ON 4 3360 ms
62 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 9.7 Low-Power Mode versus Remote’s Sleep ModeThe Low-Power Mode (LPM) puts Remote radios into an operational config-uration similar to Sleep, but there are some important differences. Below is a comparison of the two modes.9.8 Mobile Operation SupportIntroductionReliable mobile operation of Remotes is practical in areas covered by multiple Master Stations within the same network—Master stations with the same Network Address (ADDR). To make this type of service practical, the Remote must have several reliable Master stations with which to communi-cate. A “reliable” Master is defined as one, which consistently matches, or exceeds, the Remote’s standard for Minimum RSSI (MRSSI). Initially, the Remote will favor Masters with signal strengths 10 dB greater than the MRSSI threshold. This will allows for some signal degradation of the new Master as the Remote travels.When the average signal level from the currently-associated Master falls below the user-defined MRSSI level, the Remote will become out-of-sync and seek an alternate Master with a reliable signal.Table 25. Power-Conservation Modes ComparisonSleep Mode Low-Power ModeFeatures • Manual control by connected equipment• Selective application of Sleep control •User determines length and frequency of sleep periods• Automatic radio-controlled timing• Automatic sleep during absence of directed traffic• Network-wide implementation through Master stationBenefits • Low latency• Low standby power, ≤ 3 mA at 13.6 Vdc•Greatest potential for power savings• Less complicated implementation• Simple configuration
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 63Operational Influences—Hoptime & SAFThe synchronization period is influenced by two parameters’ values—HOPTIME and SAF (Store-and-Forward). Table 26 shows several configurations and the associated synchronization period value.9.9 MIRRORED BITS™ Protocol SupportTransNET radios are compatible with Schweitzer’s Mirrored Bits MB8 protocol, provided complementary firmware (06-4045A01) is installed in all network radios. A detailed application guide (AG2003-07) is available from Schweitzer Engineering Labs Web site, www.SELinc.com/aglist.htm, or from Microwave Data Systems’ Web site at www.microwavedata.com. 9.10 Seamless Mode EmulationThe RXD command assumes the payload message will be ready for transmis-sion after the delay period has expired. If there is a chance the payload data may be delayed, it is recommended to use the BUFF(er) command to make sure the entire message is received before delivery is started. The BUFF command provides a highly-reliable seamless operating mode, but can be very slow to start, especially if it waits for the reception of long messages before passing on the message.9.11 Full-Duplex EmulationIf your system design needs to support PTP or Point-to-Multipoint applica-tions and your communications must appear to be full-duplex to the connected devices, set the Master to CSADDR xxxxx (where xxxxx is the Network Address (ADDR). This will place the system in a time-division duplex mode (TDD). The radio system will appear to be full-duplex to the connected devices, but actually operates half-duplex over the radio link. Data is buffered by the transmitting side until it is its turn to transmit. Throughput will be approximately 1/2 of the DATA interface rate. 9.12 Co-Located and Close-Proximity MastersIf your requirements call for multiple TransNET networks at the same loca-tion, you need to ensure that interference between the systems in minimized to prevent overload that will diminish the performance of the radios. Tradi-tionally, vertical separation of the antennas of co-located radios was required Table 26. Synchronization Period versus Hoptime and SAF SettingsSync Period Hoptime Value SAF441 ms 7 OFF1.8 sec 28 OFF3.5 sec 28 ON
64 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D in order to reduce the interference to the point where overload of one network by the other will not occur. The CSADDR command will provide relief from this antenna separation requirement by operating the networks in a TDD mode and ensuring that one Master cannot transmit while the other (or multiple others) are trying to receive a signal from a distant radio.Master Station ConfigurationOn all Masters for which you wish to synchronize transmissions, establish one Master as the “Clock-Sync Master by setting its CSADDR value to it own Network Address (ADDR xxxxx). Then, set all other dependent Masters CSADDR values to the Network Address (ADDR) of the Clock-Sync Master. Make sure that you use a different Network Address (ADDR) for each Master. This value will be used to identify all units associated with this Master’s network.Note that all Masters must be set to the same CSADDR setting, but only one where the CSADDR matches its own ADDR; this is the Clock-Sync Master. CSADDR = ADDR—Unit serving as a Clock-Sync MasterCSADDR ≠≠≠≠ ADDR—Unit serves as a Dependent Master (Clock Slave)CSADDR = NONE—Co-located Master feature disabled (default)HOPTIME, FEC and SAF values are provided by the Clock-Sync Master to all dependent units.NOTE:  If a Dependent Master station is unable to find the Clock-Sync Master station, it will not be able to operate properly and the associated network will be out-of-service.Antenna System for Co-Located Master StationsUsing this TDD (Clock-Sync) mode will prevent any two Masters from trans-mitting at the same time and greatly reduce the antenna separation require-ments to near zero. Under this arrangement, the antennas of co-located Masters may be placed a few feet (less than a meter) apart horizontally, or just above or below vertically with no ill effects. There are two common antenna system arrangements:Sharing a Common Antenna SystemIt is possible to share an antenna between multiple Masters using stan-dard power dividers, as long as the extra loss associated with these devices is taken into account in your RF budgeting process. Masters in this configuration must be operating with Clock-Sync (CSADDR) enabled. For example, the two Master stations shown in Figure 20 are connected to a common antenna system. They use a power-divider that will result in a signal loss of 3 dB, or one-half power level, on both transmit and receive signals.The power divider, such as a Mini-Circuits ZAPD-1 or similar product, must be capable of handling 1 Watt and have >25 dB isolation between TX ports.
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 65Invisible place holderFigure 20. Co-Located Masters Sharing an Antenna9.13 SecurityToday, the operation and management of an enterprise is becoming increasing dependent on electronic information flow. An accompanying concern becomes the security of the communication infrastructure and the security of the data itself. MDS takes this matter seriously, and provides several means for protecting the data carried over its wireless products.The radio addresses this issue primarily through the use of the following items: 1. A proprietary modem/data link layer—Data signals are processed using code and hardware specifically designed by MDS.2. A unique Network Address—This provides a unique identifier for each radio in a network. A radio is not addressable unless this unique code is included in the data string.3. An optional encryption value (code)—Setting an encryption code requires the use of the CODE command. This command scrambles the radio’s hop pattern and encrypts payload data content. A radio requires the correct Network Address (ADDR) and CODE value in order to synchronize. When the CODE command is used, the same value must be programmed into all radios in the network. See “CODE [NONE, 1…255]”  on Page 31 for more details.The effective combination of CODE and ADDR discourage the use of an exhaustive search to gain access to a system. The items described above provide sufficient security for a typical MAS system. For more highly-sensitive applications, system designers should consider employing application level encryption into their polling protocols to further protect their systems. Third party software tools are available for adding encryption, and these should be considered as part of any advanced encryption scheme.Master—Network “A”CS MasterPowerDivider  (– 3 dB)OmnidirectionalAntennaMaster—Network “B”CS SlaveNetwork “A” Network “B”
66 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 10.0 TECHNICAL REFERENCE10.1 Product Specifications—900 MHzGENERALFrequency Hopping Range: 902–928 MHz,Subdivided into eight 3 MHz zones Hop Pattern: Based on network addressFrequency Stability: ±1.5 ppmHalf-Duplex Operation: ±1.6 MHz TX/RX splitNetwork Addresses: 65,000Temperature Range: –40° C to +70° CHumidity: <95% at +40° C; non-condensingPrimary Power: 13.8 Vdc, Nominal (6–30 Vdc range)Current Draw (typical @ 30 dBm):Transmit: 510 mA @ 13.8 VdcReceive: 115 mA @ 13.8 VdcSleep Mode: ≤ 3 mA @ 13.8 VdcSize: 5.30˝ W x 3.50˝ D x 1.40˝ H (135 W x 89 D x 36 H mm):Weight:1 Lb/0.5 k w/o brackets; 1.15 Lb / 0.52 k w/bracketsWeight: 1 Lb / 0.5 k w/o brackets; 1.15 Lb / 0.52 k w/bracketsCase: Die-cast aluminumAgency Approvals: • FCC Part 15.247(E5MDS-EL805)• Industry Canada RSS-210 and RSS-139   (CAN 3738A 12122)• UL/CSA Class 1, Div. 2; Groups A, B, C and D hazardous locations• Contact MDS for information on availabil-ity of governmental approvals in other countriesDATA CHARACTERISTICS   (DB-9 Data PortData Interface: RS-232/422/485Interface Connector: DB-9 femaleData Rate: 300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps asyn-chronousData Latency: 7 ms typicalByte Length: 10 or 11 bitsMaximum Data Transmission: Continuous up to 115200 bps
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 67RF CHARACTERISTICS   (TNC RF Connector)TRANSMITTER:Power Output(at antenna connector): 0.1 to 1.0 Watt (+20 dBm to +30 dBm), set by userDuty Cycle: ContinuousModulation Type: Binary CPFSKOutput Impedance: 50 OhmsSpurious: –49 dBm, 216 MHz–960 MHz–41 dBm above 960 MHzRECEIVER:Type: Double-conversion superheterodyneSensitivity: –108 dBm @ 10–6 BERIntermodulation: 54 dB minimum (EIA)Desensitization: 75 dBSpurious: 70 dB minimumBandwidth: 200 kHzInterference Ratio(SINAD degraded by 3dB): Co-channel: –10 dBAdjacent channel: +30 dBTwo channels away: +40 dBThree channels away: +48 dBTime Required to Synchronizewith Master Radio: 0.5 seconds (typical)10.2 Product Specifications—2.4 GHzGENERALFrequency Band: 2401.6–2477.8 MHz ISM bandA: 2401.6 MHz–2427.0 MHzB: 2427.2 MHz–2452.6 MHzC: 2452.8 MHz–2478.2 MHzSubdivided into eight 3 MHz zones.Hop Pattern: Based on network addressFrequency Stability:  ±1.5 ppmHalf-Duplex Operation:  ±1.6 MHz TX/RX splitNetwork Addresses:  65,000Temperature Range:  –40° C to +70° CHumidity:  <95% RH at +40° C; non-condensingPrimary Power:  13.8 Vdc, Nominal (6–30 Vdc range)Current Draw (typical @ 27 dBm): Transmit:  510 mA @ 13.8 VdcReceive:  100 mA @ 13.8 VdcSleep Mode (typical):  ≤ 3 mA @ 13.8 Vdc
68 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Size: 5.30˝ W x 3.50˝ D x 1.40˝H (135 W x 89 D x 36 H mm). Weight: 1 Lb/0.5 k w/o brackets; 1.15 Lb / 0.52 k w/bracketsWeight:  1 Lb / 0.5 k w/o brackets; 1.15 Lb / 0.52 k w/bracketsCase: Die-cast aluminumAgency Approvals.  • FCC Part 15 Pending (E5MDS-EL805-24)• IC: Approved• Contact MDS for information on avail-ability of governmental approvals in other countriesDATA CHARACTERISTICS   (DB-9 Data Port)Data Interface:  RS-232/422/485Interface Connector:  DB-9 femaleData Rate.  300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps asyn-chronousData Latency:  7 ms typicalByte Length:  10 or 11 bitsMaximum Data Transmission:  Continuous up to 115200 bpsRF CHARACTERISTICS   (TNC RF Connector)TRANSMITTER: Power Output(at antenna connector): 0.1 to 0.5 watt (+20 dBm to +27 dBm), set by userDuty Cycle:  ContinuousModulation Type:  Binary CPFSKOutput Impedance:  50 OhmsSpurious: –49 dBm, 216 MHz–960 MHz–41 dBm above 960 MHzRECEIVER:Type: Double-conversion superheterodyneSensitivity:  –108 dBm @ 10–6 BERIntermodulation:  54 dB minimum (EIA)Desensitization: 75 dBSpurious:  70 dB minimumBandwidth: 200 kHz
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 6910.3 Diagnostic Interface Connections (RJ-11)Invisible place holderFigure 21. RJ-11 to DB-9 Adapter Cable—Wiring DetailsNOTE:  Only wire pins 4, 5, and 6. Pins 1,2, and 3 are reserved for special functions and are not normally connected.10.4 Data Interface Connections (DB-9F)The DATA connector (Figure 22) is used to connect the radio to an external DTE data terminal that supports the EIA/RS-232 or EIA/RS-485 (balanced) format, depending on how the radio was configured at the factory. The radio supports data rates of 300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bps (asynchronous data only).The DATA connector mates with a standard DB-9 plug that is available from many electronics parts distributors. Table 27 and Table 28 provide detailed pin descriptions for the DATA connector in RS/EIA-232 mode and RS/EIA-485 mode, respectively.Pin Descriptions—RS/EIA-232 ModeFigure 22. DATA Connector (DB-9F)As viewed from outside the radioRXDTXDGND235DTEDB-9 FEMALE(TO COMPUTER)TXDRXDGND456DTERJ-11 PLUG(TO RADIO)RJ-11 PIN LAYOUT165961
70 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Pin Descriptions—RS/EIA-232 ModeTable 27 lists the DATA connector pin functions for radios configured to operate in RS/EIA-232 mode. NOTE:  The radio is hard-wired as a DCE in the EIA-232 mode.Table 27. DATA connector pin descriptions—RS/EIA-232  PinNumberInput/Output Pin Description1 OUT DCD (Data Carrier Detect)A “high” indicates hopping synchronization.2 OUT RXD (Received Data)Supplies received data to the connected device.3INTXD (Transmitted Data)Accepts TX data from the connected device.4INSleep—A ground on this pin turns off most circuits in a Re-mote radio, including transmit, receive, modem, and diag-nostic functions. This allows for greatly reduced power consumption, yet preserves the radio’s ability to be quickly brought on line. See “Using the Radio’s Sleep Mode (Re-mote Units Only)” on Page 59 for details.5INSignal Ground—Connects to ground (negative supply potential) on the ra-dio’s PC board and chassis.6 OUT Alarm Output—An RS-232 high/space (+5.0 Vdc) on this pin indicates an alarm condition. An RS-232 low/mark (–5.0 Vdc) indicates normal operation. This pin may be used as an alarm output. (See ASENSE [HI/LO] Details, page 29 for further information.)7INRTS (Request-to-Send)8 OUT CTS (Clear-to-Send)—Goes “high” after the programmed CTS delay time has elapsed (DCE), or keys an attached ra-dio when RF data arrives (CTS KEY).9--Reserved for Special Uses (Do not connect)
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 71Pin Descriptions—RS/EIA-422/485 ModeTable 28 lists the DATA connector pin functions for radios configured to operate in RS/EIA-422/485 mode. See Figure 23 for wiring schemes.NOTES:• RXD+ / RXA and RXD– / RXB are data sent into the radio to be transmitted out• RXD+ / RXA is positive with respect to RXD– / RXB when the line input is a “0”•TXD+ / TXA and TXD– / TXB are data received by the radio and sent to the connected device• TXD+ / TXA is positive with respect to the TXD– / TXB when the line output is a “0”Invisible place holderFigure 23. EIA-422/485 Wiring Schemes(Left: EIA-422, Right: EIA-485)Table 28. DATA connector pin descriptions—RS/EIA-485 Mode  PinNumberInput/Output Pin Description1—Not Used—Do not connect2 OUT TXD+/TXA—Non-inverting driver output. Supplies data to the connected device.3INRXD+/RXA—Non-inverting receiver input. Accepts data from the connected device.4INSleep—A ground on this pin turns off most circuits in a Re-mote radio, including transmit, receive, modem, and diag-nostic functions. This allows for greatly reduced power consumption, yet preserves the radio’s ability to be quickly brought on line. See “Using the Radio’s Sleep Mode (Re-mote Units Only)” on Page 59 for details.5--Signal Ground (GND)—Connects to ground (negative sup-ply potential) on the radio’s PC board and chassis.6--Not Used—Do not connect7INRXD– /RXB—Inverting receiving input8 OUT TXD– /TXB—Inverting driver output.9--Open (User configurable via internal jumper. See“User Configurable I/O Connections”  on Page 72)2-WIRE CONNECTIONS4-WIRE CONNECTIONSTXD +RXD +237RADIODATA CONNECTOR8RXD –TXD –EXTERNAL DEVICERXD –TXD +RXD +TXD –RXD+/TXD+237RADIODATA CONNECTOR8RXD–/TXD–EXTERNAL DEVICERXD –TXD +RXD +TXD –
72 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 10.5 User Configurable I/O ConnectionsSeveral connection points (eyelets) are provided within the transceiver near the DATA interface connector that allow the user to facilitate unique integra-tion requirements. By jumpering eyelets, external functions (unconditioned I/O) may be communicated within the TransNET network using a Network Management System (NMS) such as MDS’ InSite or a user’s custom application that uses the Network-Wide Diagnostics Protocol. Specifications for this protocol are open and are contained within the InSite distribution material on CD and on the MDS Web site.One pin of the DB-9 Data Interface connector supports this function, as well as three pins of the RJ-11 Diagnostics connector. See Tables 27 and 28 on the previous pages for details.Care should be taken when soldering to the PCB eyelets due to their small size. For this reason, only qualified personnel should install the jumpers and external connections.Installation of internal jumpers and connection to non-standard interface pins may void the product’s warranty. If you are uncertain of your interface design, please consult with the MDS Technical Services Department for a review of your design to assure maintenance of your warranty. Invisible place holderFigure 24. User Interface I/O Jumper EyeletsPCBs 03-4040A03/A04 and laterNOTE:  If your PCB does not look like the one in the Figure 24, consult with the MDS Technical Services for assistance.Each pin connected to user-designed equipment must be connected through a special cable constructed to breakout the User I/O pins.Your interface can complement your unique requirements. The input signals and output interface must be within the radio’s interface parameters as summarized in Table 29. CAUTIONPOTENTIAL EQUIPMENT DAMAGE
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide 73Using the I/O Points with InSite™ NMS SoftwareMDS’ InSite has the ability to read the user analog input (Analog 1) and two user-configurable and independent I/O signals (I/O 1 & I/O 2). Each I/O connection can independently configured as input or output. If configured as an output, a saved default output value can be stored in the radio to ensure the radio boots to the desired state for this pin. The values of I/O 1 & I/O 2 can be read and displayed by an InSite user to determine the current state. The values of I/O 1 & I/O 2 at the TransNET’s DATA Interface connector will remain in a constant state until manually changed though the InSite Configuration screen.Application Example—Digital Input and Output at a RemoteA typical application of the user I/O connections may require one digital input and one digital output to be controlled by network diagnostics. In this example, H3 could be jumpered to H7 (I/O 1 to RJ-11, Pin 1) and H4 jumpered to H8 (I/O 2 to RJ-11, Pin 2). Using InSite, I/O 1 could be configured as an output and I/O 2 as an input.Table 29. TransNET User I/O Connection Resources  Function or Service Range Available at eyelet:Filtered Receive Audio(For test purposes) 0 – 5 Vac, 30–5 kHz H2General Purpose I/O 1 (GPIO 1)aTTL; External 10K to 3.3 V Vcc Recommended H3General Purpose I/O 2 (GPIO 2)bTTL; External 10K to 3.3 V Vcc Recommended H4Analog 1c0 – 5 Vac, ≤ 60 HZ H6Do not connect. Factory use only.  H5Data Interface Pin Available at eyelet:DB-9, Pin 9 H1RJ-11, Pin 1 H7RJ-11, Pin 2 H8RJ-11, Pin 3 H9a. Configuration and data retrievable via MDS InSite™ software as “I/O 1”b. Configuration and data retrievable via MDS InSite™ software as “I/O 2”c. Parameter retrievable via MDS InSite™ software
74 MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D 10.6 dBm-Watts-Volts Conversion ChartTable 30 is provided as a convenience for determining the equivalent voltage or wattage of an RF power expressed in dBm with 50 Ohms load.Table 30. dBm-Watts-Volts Conversion ChartdBm V Po+53 100.0 200W+50 70.7 100W+49 64.0 80W+48 58.0 64W+47 50.0 50W+46 44.5 40W+45 40.0 32W+44 32.5 25W+43 32.0 20W+42 28.0 16W+41 26.2 12.5W+40 22.5 10W+39 20.0 8W+38 18.0 6.4W+37 16.0 5W+36 14.1 4W+35 12.5 3.2W+34 11.5 2.5W+33 10.0 2W+32 9.0 1.6W+31 8.0 1.25W+30 7.10 1.0W+29 6.40 800mW+28 5.80 640mW+27 5.00 500mW+26 4.45 400mW+25 4.00 320mW+24 3.55 250mW+23 3.20 200mW+22 2.80 160mW+21 2.52 125mW+20 2.25 100mW+19 2.00 80mW+18 1.80 64mW+17 1.60 50mW+16 1.41 40mW+15 1.25 32mW+14 1.15 25mW+13 1.00 20mW+12 .90 16mW+11 .80 12.5mW+10 .71 10mW+9 .64 8mW+8 .58 6.4mW+7 .500 5mW+6 .445 4mW+5 .400 3.2mW+4 .355 2.5mW+3 .320 2.0mW+2 .280 1.6mW+1 .252 1.25mWdBm V Po0 .225 1.0mW-1 .200 .80mW-2 .180 .64mW-3 .160 .50mW-4 .141 .40mW-5 .125 .32mW-6 .115 .25mW-7 .100 .20mW-8 .090 .16mW-9 .080 .125mW-10 .071 .10mW-11 .064-12 .058-13 .050-14 .045-15 .040-16 .0355dBm mV Po-17 31.5-18 28.5-19 25.1-20 22.5 .01mW-21 20.0-22 17.9-23 15.9-24 14.1-25 12.8-26 11.5-27 10.0-28 8.9-29 8.0-30 7.1 .001mW-31 6.25-32 5.8-33 5.0-34 4.5-35 4.0-36 3.5-37 3.2-38 2.85-39 2.5-40 2.25 .1µW-41 2.0-42 1.8-43 1.6-44 1.4-45 1.25-46 1.18-47 1.00-48 0.90dBm mV Po-49 0.80-50 0.71 .01µW-51 0.64-52 0.57-53 0.50-54 0.45-55 0.40-56 0.351-57 0.32-58 0.286-59 0.251-60 0.225 .001µW-61 0.200-62 0.180-63 0.160-64 0.141dBm µV Po-65 128-66 115-67 100-68 90-69 80-70 71 .1nW-71 65-72 58-73 50-74 45-75 40-76 35-77 32-78 29-79 25-80 22.5 .01nW-81 20.0-82 18.0-83 16.0-84 11.1-85 12.9-86 11.5-87 10.0-88 9.0-89 8.0-90 7.1 .001nW-91 6.1-92 5.75-93 5.0-94 4.5-95 4.0-96 3.51-97 3.2dBm µV Po-98 2.9-99 2.51-100 2.25 .1pW-101 2.0-102 1.8-103 1.6-104 1.41-105 1.27-106 1.18dBm nV Po-107 1000-108 900-109 800-110 710 .01pW-111 640-112 580-113 500-114 450-115 400-116 355-117 325-118 285-119 251-120 225.001pW-121 200-122 180-123 160-124 141-125 128-126 117-127 100-128 90-129 80 .1ƒW-130 71-131 61-132 58-133 50-134 45-135 40-136 35-137 33-138 29-139 25-140 23 .01ƒW
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide iINDEXAAccessories (table) 5ADDR command (set/display radio network address) 29Alarmchecking for 46code definitions 47codes 46codes, table 47major vs. minor 46receiver timeout (RXTOT command) 40reset output signal 29set/display output sense (ASENSE command) 29status (STAT command) 43ALARM command (superseded; see STAT command) 43Alarm Mask (AMASK) Command 29Alarm Sense (ASENSE) Command 29Alarm Status Command (STAT) 43AMASK command (configure alarm output signal) 29Antennainstallation 15performance optimization 20selection 9SWR check 21system gain vs. power output setting, table 13Yagi, illustrated 10ASENSE command (set/display alarm output sense) 29BBAUD command (set/display data interface port attributes) 29Baud ratesetting 22setting for RJ-11 DIAG port (DLINK command) 49BUFF command (set/display received data handling mode) 30CCabledata equipment to DATA INTERFACE connector 15, 22data interface wiring for tail-end links 19feedlines 10maximum length, recommended 16, 71Clear Zone Statisics Log, ZONE CLEAR 44Clear-to-Send Delay (CTS) Command 31Clear-to-Send Hold Time (CTSHOLD) Command 32Clock-Synchronizing Master Address (CSADDR) Command 31CODE command (display/set encryption value) 31Command 36TEMP (radio’s internal temperature reading) 43Commands
ii MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D ADDR (set/display radio network address) 29AMASK (configure alarm output signal) 29ASENSE (set/display alarm output sense) 29BAUD (set/display data interface port attributes) 29BUFF (set/display received data handling mode) 30CODE (set/display encryption value), See also Encryption 31CTS (set/display CTS line response timer) 31CTSHOLD (set/display CTS hold timer) 32detailed descriptions 28–44DEVICE (set/display DCE or CTS Key behavior) 32display operating status 24DKEY Command, Turn off radio transmitter test signal 33DTYPE (set radio’s diagnostics type) 33FEC (Forward Error Correction) 33FEC (Forward Error Correction) Command 33HOPTIME (set/display hoptime setting) 34how used 28INIT (restore factory default settings) 34LPM (low-power mode) 36LPMHOLD (low-power mode sleep time) 36MODE (display/set radio mode as master, remote, or extension) 36MODE (radio operating mode) 36most often used commands 28network configuration 23OWM (set/display optional owner’s message) 37OWN (set/display optional owner’s name) 37PORT (display/set current data port) 37PWR (set/display RF forward output power) 38Radio transmitter test frequency (TX) 43RSSI (display received signal strength) 38RTU (enable/disable internal RTU) 39RX (set/display receiver test frequency) 39RXD 39RXTOT (set/display received data timeout value) 40SAF (store-and-forward) 40SER (radio serial number) 40SETUP (enter testing and setup mode) 40SHOW (display measured power output) 41SHOW PWR (show power) 41SHOW SYNC 41SHOW SYNC (show Clock-Synchronization Master) 41SKIP (set/display frequency zone to skip) 41SLEEP (display/set radio’s sleep mode setting) 42SLEEP (transceiver sleep mode) 42SREV (firmware/software revision level) 42STAT (list alarms) 43TEMP (display internal temperature) 43UNIT (unit address) 43XADDR (extended address) 44XMAP (Map of Extension Addresses) 44
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide iiiXPRI (display/program primary radio’s extended address) 44XRSSI (sets minimum signal level for sync. with non-primary extension unit) 44ConnectorsDiagnostic Interface, Connections 69DData Baud Rate (BAUD) Command 29Data Baud Rate (BUFF) Command 30Data buffer setting 21, 30DATA INTERFACEcable wiring for tail-end links, illustrated 19connections 69connector pin descriptions, table 70Data Port Signalling Standard (PORT) Command 37Default settingsdata interface baud rate 22factory settings reset by INIT command (table) 34restoring (INIT command) 34See also individual command descriptionsDEVICE Command 32DEVICE command (set/display DCE or CTS Key behavior) 32Diagnosticsnetwork-wide, performing 49setup mode (SETUP command) 40using InSite software for network-wide 49Diagnostics Link (DLINK) 32Displayalarm output sense (ASENSE command) 29alarms (STAT command) 43CTS hold timer value (CTSHOLD command) 32CTS line response timer value (CTS command) 31data interface baud rate (BAUD command) 29device behavior (DEVICE command) 32hoptime setting (HOPTIME command) 34network address (ADDR command) 29operating status commands 24owner’s message (OWM command) 37owner’s name (OWN command) 37receive test frequency (RX command) 39received data handling mode (BUFF command) 30received data timeout value (RXTOT command) 40received signal strength (RSSI command) 38RF forward output power (PWR command) 38RF power output, actual measured (SHOW command) 41skipped frequency zones (SKIP command) 41temperature, internal (TEMP command) 43display/set radio mode as master, remote, or extension (see MODE command) 36DKEY command (disable transmitter) 21, 40DKEY, Disable Transmitter, Command 33DLINK command (set/display baud rate of diagnostics link) 49
iv MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D Downstream Repeat Transmission Count (REPEAT) Command 38DSP (digital signal processing) 1, 47DTYPE command (set radio’s diagnostics type) 33, 49, 50EEnableinternal RTU (RTU command) 39network-wide diagnostics, procedures 49Setup mode (SETUP command) 40skipped zone (SKIP command) 41Sleep ModeEnable/Disable LEDs (LED) Command 36Encryption. See CODE commandEquipment List 33Extended Address Command (XADDR) 44Extension radio. See Store-and-Forward (SAF)FFeedlineselection 9, 10Firmware Revision Level Command (SREV) 42Forward-Error Correction (FEC) Command 33Fuse Replacement 50GGate (radio diagnostics type) 33, 50HHardware Revision (HREV) Command 35Hayes-Compatible AT Command (AT) 29Hoptimesetting 21HOPTIME Command (radio transmitter hop timing) 34HOPTIME command (set/display hoptime setting) 34IIllustrationsantenna, Yagi 10data interface cable wiring for tail-end links 19model configuration code 72point-to-point link 3remote station arrangement 6tail-end link 4typical MAS network 3INIT command (restore factory default settings) 34Initialize 34InSite software 49Installationantenna 15connecting transceiver to data equipment 15, 22
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide vfeedline selection 10performance optimization 20requirements 6site selection 6site survey 7tail-end links 18transmission path 7Interferenceabout 8checks 22troubleshooting 48interference 8KKeyset to CTS keying (DEVICE command) 32transmitter, for antenna SWR check 21KEY command (key transmitter) 21, 40LLED status indicatorstable 20, 46Low-Power Mode (LPM) Command 36Low-Power Mode Sleep Time (LPMHOLD) Command 36LPM Command (low-power mode) 36LPMHOLD Command 36MMap 44Map of Extension Addressses (XMAP) 44Master Stationdefault settings 34MIRRORED BITS™ Protocol Support 62, 63MODE Command 36MODE command (display/set radio mode as master, remote, or extension) 36MODE command (display/set radio’s operating mode as master, remote, or extension) 36, 37Model configuration code, illustrated 72ModesLow-Power Mode versus Remote’s Sleep 62Mounting instructions/dimensions 14–15Multiple Address System (MAS)network, illustrated 3Multiple Address Systems (MAS) 2NNetwork Address (ADDR) Command 29Network configuration commands 23Network Diangnsotics Mode (DTYPE) Command 33Network-wide diagnostics
vi MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D procedures 49Node (radio diagnostics type) 33, 50OLED 36Modbus, BUFF 30Operation 19–22OWM command (set/display optional owner’s message) 37OWN command (set/display optional owner’s name) 37Owner’s Message (OWM) Command 37Owner’s Name Command (OWN) 37PPCconnecting to radio’s diagnostic port 49launching InSite application at 49performing diagnostics using connected 49Peer (radio diagnostics type) 33, 50Performance optimization 20Pins, DATA INTERFACE connector descriptions (table) 70Point-to-point systemlink, illustrated 3Point-to-Point System (P-P) 3PORT command (set/display current data port) 37PowerLow-Power Mode versus Remote’s Sleep 62Power (RF)how much can be used 11Measurement 41set/display RF forward output (PWR command) 38Power saving mode (see Sleep Mode)Primary Extension Address (XPRI) 44Proceduresantenna aiming 20antenna and feedline selection 9antenna SWR check 21connecting data equipment to DATA INTERFACE connector 15, 22connecting PC and radios for network-wide diagnostics 49enabling sleep modeinstallation planning 6installing the antenna and feedline 15interference check 22mounting the transceiver 14–15network-wide diagnostics 49performance optimization 20performing network-wide diagnostics 49programming radio for network-wide diagnostics 49reading LED status indicators 19site selection 6troubleshooting 45–48
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide viiProgramming radio 28–44as root or node 49PWR command (set/display RF forward output power) 38RRadioinoperative (troubleshooting chart) 48no synchronization with master (troubleshooting chart) 48poor performance (troubleshooting chart) 48Radio Operating Mode (MODE) Command 36, 37Radio Receive Test Frequency Command (RX) 39Radio Serial Number Command (SER) 40Radio Transmit Test Frequency (TX) 43Radio Transmitter Hop Timing (HOPTIME) 34Radio Transmitter Power Level (PWR) Command 38Radio’s Internal Temperature Command (TEMP) 43Radio-MODEM Behavior (DEVICE) Command 32Receive Data Timeout-Timer Command (RXTOT) 40Received Signal Strength Indicator Command (RSSI) 38Remote radiodefault settings 34Remote stationtypical arrangement, illustrated 6Remote Terminal Unit Simulator Command (RTU) 39Repeater Operation. See Store-and-Forward (SAF)Restore to Factory Defaults (INIT) 34RJ-11Diagnostic Interface, Connection 69Root (radio diagnostics type) 33, 50RSSI command (display received signal strength) 38RTU command (enable/disable internal RTU) 39RX command (set/display test receive frequency) 39RXD Command 39RXD Delay Command (RXD) 39RXTOT command (set/display received data timeout value) 40SSAF command (store-and-forward) 40SecurityNetwork Address 65optional encryption value 65Security Code (CODE) Command 31Security, Data 65SER Command 40Setalarm output sense (ASENSE command) 29alarm output signal (AMASK command) 29CTS hold timer (CTSHOLD command) 32CTS line response timer (CTS command) 31data interface baud rate (BAUD command) 29
viii MDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D DCE or CTS Key device behavior (DEVICE command) 32frequency zone to skip (SKIP command) 41hoptime (HOPTIME command) 34network address (ADDR command) 29owner’s message (OWM command) 37owner’s name (OWN command) 37radio mode (see MODE command) 36received data handling mode (BUFF command) 30received data timeout value (RXTOT command) 40receiver test frequency (RX command) 39testing mode (SETUP command) 40SETUP command (enter testing and setup mode) 40Setup Radio Test (SETUP) 40Show Clock-Synchronization Master Network Address (SHOW SYNC) 41SHOW command (display power output) 41SHOW CON Command (show virtual connection status) 41Show Measured RF Transmit Power (SHOW PWR) 41SHOW SYNC Command 41Show Virtual Connection Status Command (SHOW CON) 41Site selection 6SKIP command (set/display frequency zone to skip) 41Skip Radio Operating Zones (SKIP) 41SLEEP command (display/set radio’s sleep setting) 42SLEEP command (transceiver sleep ON/OFF) 42Sleep Mode 59Spread spectrum, basic principles of 2SREV Command 42STAT command (list alarms) 43Store-and-Forward (SAF) 4, 23, 27, 34, 40, 45, 52, 57Store-and-Forward Services (SAF) Support Command 40SWR (Standing Wave Ratio)performance optimization 21Synchronization qualifiers 46, 55synchronization, check 8TTablesaccessories 5alarm codes 47antenna system gain vs. power output setting 13DATA INTERFACE connector pin descriptions 70LED status indicators 20, 46troubleshooting 48Tail-end linkAdding to Existing Network 3cable wiring for, illustrated 19illustrated 4installation 18Technical specifications 66–68TEMP command (display internal temperature) 43
MDS 05-2708A01, Rev.  D MDS TransNET I&O Guide ixTemperature, display internal (TEMP command) 43Terrain 7Terrain and Signal Strength 7Test, on-the-air 7Transceiverconnecting to data equipment 15, 22default settings 34mounting instructions/dimensions 14–15performance optimization 20sleep mode 59Transceiver Sleep (SLEEP) 42Troubleshooting 45–48performing network-wide diagnostics 49table 48Turn Off Radio Transmitter Test Signal (DKEY) Command 33Turn On Radio Transmitter Test Signal (KEY) Command 35UUNIT Command (unit address) 43Upstream Repeat Transmission Count Command (RETRY) 38XXADDR (extended address command) 17, 27, 34, 35, 45, 55, 58XADDR (extended address) Command 37XPRI command (display/set extended address) 44XRSSI command (sets minimum RSSI level to maintain sync. w/non-primary extension radio) 44ZZONE CLEAR (clear zone statistics log) 44ZONE DATA Command (read zone statistics log) 44Zone, Clear Statistics Log (ZONE CLEAR) 44Zone, Read Statistics Log (ZONE DATA) 44
xMDS TransNET I&O Guide  MDS 05-2708A01, Rev.  D
N CASE OF DIFFICULTY...MDS products are designed for long life and trouble-free operation. However, this equipment, as with all electronic equipment, may have an occasional component failure. The following information will assist you in the event that servicing becomes necessary.TECHNICAL ASSISTANCETechnical assistance for MDS products is available from our Technical Support Department during business hours (8:00 A.M.–5:30 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble/symptom(s) that you are experiencing. In many cases, problems can be resolved over the telephone, without the need for returning the unit to the factory. Please use one of the following means for product assistance:Phone:585 241-5510  E-Mail: TechSupport@microwavedata.comFAX: 585 242-8369 Web: www.microwavedata.comFACTORY SERVICEComponent level repair of radio equipment is not recommended in the field. Many components are installed using surface mount technology, which requires specialized training and equipment for proper servicing. For this reason, the equipment should be returned to the factory for any PC board repairs. The factory is best equipped to diagnose, repair and align your radio to its proper operating specifications.If return of the equipment is necessary, you will be issued a Service Request Order (SRO) number. The SRO number will help expedite the repair so that the equipment can be repaired and returned to you as quickly as possible. Please be sure to include the SRO number on the outside of the shipping box, and on any correspondence relating to the repair. No equipment will be accepted for repair without an SRO number.A statement should accompany the radio describing, in detail, the trouble symptom(s), and a description of any associated equipment normally connected to the radio. It is also important to include the name and telephone number of a person in your organization who can be contacted if additional information is required.The radio must be properly packed for return to the factory. The original ship-ping container and packaging materials should be used whenever possible. All factory returns should be addressed to:Microwave Data SystemsProduct Services Department(SRO No. XXXX)175 Science ParkwayRochester, NY 14620 USAWhen repairs have been completed, the equipment will be returned to you by the same shipping method used to send it to the factory. Please specify if you wish to make different shipping arrangements. To inquire about an in-process repair, you may contact our Product Services Group at 585-241-5540 (FAX: 585-242-8400), or via e-mail at ProductServices@microwavedata.com.
Microwave Data Systems Inc.Rochester, NY 14620General Business: +1 585 242-9600FAX: +1 585 242-9620Web: www.microwavedata.com175 Science ParkwayA product of Microwave Data Systems Inc.