GE MDS DS9710-1 9710A Data Transceiver User Manual Exhibit 22 Installation and Operation Guide

GE MDS LLC 9710A Data Transceiver Exhibit 22 Installation and Operation Guide

Contents

Exhibit 22 Installation and Operation Guide

Download: GE MDS DS9710-1 9710A Data Transceiver User Manual Exhibit 22  Installation and Operation Guide
Mirror Download [FCC.gov]GE MDS DS9710-1 9710A Data Transceiver User Manual Exhibit 22  Installation and Operation Guide
Document ID116062
Application IDZZps+5tngcFT1Pq3UVJiMw==
Document DescriptionExhibit 22 Installation and Operation Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize108.97kB (1362157 bits)
Date Submitted2000-09-07 00:00:00
Date Available2000-11-30 00:00:00
Creation Date1999-02-18 13:49:16
Producing SoftwareAcrobat Distiller 3.01 for Power Macintosh
Document Lastmod2000-09-06 13:23:35
Document Title3305 4710A and 9710A Transceiver Installation and Operation Guide
Document CreatorFrameMaker 5.5.3
Document Author: Microwave Data Systems

Data Transceiver
MDS 05-3305A01, REV. A
JANUARY 1999
Installation and Operation Guide
MDS 4710A/9710A
QUICK START GUIDE
Below are the basic steps for installing the transceiver. Detailed instructions are given in ÒINSTALLATIONÓ on page 9 of this guide.
1.
Install and connect the antenna system to the radio
¥ Use good quality, low loss coaxial cable. Keep the feedline as short as possible.
¥ Preset directional antennas in the direction of desired transmission.
2.
Connect the data equipment to the radioÕs INTERFACE connector
¥ Connection to the radio must be made with a DB-25 Male connector. Connections for typical systems are shown below.
¥ Connect only the required pins. Do not use a straight-through RS-232 cable with all pins wired.
¥ Verify the data equipment is conÞgured as DTE. (By default, the radio is conÞgured as DCE.)
DB-9 to DB-25 Example
DB-25
GND
DCD
TXD
TXD
RXD
RXD
RXD
RXD
TXD
TXD
RTS
RTS
75
CTS
CTS
GN
DSR
20
GN
DSR
DSR
DSR
RTS
RTS
CTS
CTS
GND
20
GND
DCD
DCD
RTU
(DTE)
DB-25
DCD
TRANSCEIVER
(DCE)
DB-9
DB-25
GND
TRANSCEIVER
(DCE)
RTU
(DTE)
DB-25 to DB-25 Example
As required for application
As required for application
3.
Apply DC power to the radio (10.5Ð16 Vdc @ 2.5 A minimum)
¥ Observe proper polarity. The red wire is the positive lead; the black is negative.
4.
Set the radioÕs basic conÞguration with a Hand-Held Terminal (HHT)
¥ Set the transmit frequency (TX xxx.xxxx).
¥ Set the receive frequency (RX xxx.xxxx).
¥ Set the baud rate/data interface parameters as follows. Use the BAUD xxxxx abc command, where
xxxxx equals the data speed (110Ð38400 bps) and abc equals the communication parameters as
follows:
a = Data bits (7 or 8)
b = Parity (N for None, O for Odd, E for Even
c = Stop bits (1 or 2)
(Example: BAUD 9600 8N1)
NOTE: 7N1, 8E2 and 8O2 are invalid parameters and are not supported by the transceiver.
5.
Verify proper operation by observing the LED display
¥ Refer to Table 4 on page 14 for a description of the status LEDs.
¥ ReÞne directional antenna headings for maximum receive signal strength using the RSSI command.
TABLE OF CONTENTS
1.0 GENERAL.................................................................................... 1
1.1
1.2
1.3
1.4
Introduction ......................................................................................1
Applications ......................................................................................2
Model Number Codes ......................................................................4
Accessories ......................................................................................5
2.0 GLOSSARY OF TERMS.............................................................. 6
3.0 INSTALLATION ............................................................................ 9
3.1
3.2
3.3
3.4
3.5
3.6
Installation Steps ..............................................................................9
Transceiver Mounting .....................................................................11
Antennas and Feedlines ................................................................11
Power Connection ..........................................................................13
Data Interface Connections ............................................................13
Using the RadioÕs Sleep Mode .......................................................13
4.0 OPERATION .............................................................................. 15
4.1 LED Indicators ................................................................................16
4.2 RSSI Measurement ........................................................................16
5.0 TRANSCEIVER PROGRAMMING ............................................ 17
5.1
5.2
5.3
5.4
Hand-Held Terminal Connection & Startup ....................................17
Hand-Held Terminal Setup .............................................................18
Keyboard Commands .....................................................................19
Detailed Command Descriptions ...................................................22
6.0 TROUBLESHOOTING ............................................................... 31
6.1 LED Indicators ................................................................................32
6.2 Event Codes ...................................................................................32
7.0 TECHNICAL REFERENCE ....................................................... 34
7.1
7.2
7.3
7.4
7.5
MDS 4710A/9710A Transceiver SpeciÞcations ..............................34
Helical Filter Adjustment ................................................................36
Performing Network-Wide Remote Diagnostics .............................37
Upgrading the RadioÕs Software .....................................................39
dBm-Watts-Volts Conversion Chart ................................................40
INDEX................................................................................................ I-1
IN CASE OF DIFFICULTY... ..................................... Inside Rear Cover
MDS 05-3305A01, Rev. A
Installation and Operation Guide
Copyright Notice
This Installation and Operation Guide and all software described herein
are protected by copyright: 1998 Microwave Data Systems, a division
of California Microwave, Inc. All rights reserved.
Microwave Data Systems reserves its right to correct any errors and
omissions.
RF Exposure
Operational Safety Notices
The radio equipment described in this guide uses radio frequency transmitters. Although the power level is low, the concentrated energy from
a directional antenna may pose a health hazard. Do not allow people to
come closer than 0.5 meter to the front of the antenna when the transmitter is operating.
This manual is intended to guide a professional installer to install,
operate and perform basic system maintenance on the described radio.
ISO 9001 Registration
Microwave Data Systems' adherence to this internationally accepted
quality system standard provides one of the strongest assurances of
product and service quality available.
MDS Quality Policy Statement
We, the employees of Microwave Data Systems, are committed to
achieving total customer satisfaction in everything we do.
Total Customer Satisfaction in:
• Conception, design, manufacture and marketing of our products.
• Services and support we provide to our internal and external
customers.
Total Customer Satisfaction Achieved Through:
• Processes that are well documented and minimize variations.
• Partnering with suppliers who are committed to providing quality and
service.
• Measuring our performance against customer expectations and
industry leaders.
• Commitment to continuous improvement and employee involvement.
FM/UL/CSA Notice
This product is available for use in Class I, Division 2, Groups A, B,
C & D Hazardous Locations. Such locations are defined in Article 500
of the National Fire Protection Association (NFPA) publication NFPA
70, otherwise known as the National Electrical Code.
ii
MDS 4710/9710 Installation and Operation Guide
MDS 05-3305A01, Rev. A.1
The transceiver has been recognized for use in these hazardous locations
by three independent agencies ÑUnderwriters Laboratories (UL), Factory Mutual Research Corporation (FMRC) and the Canadian Standards
Association (CSA). The UL certification for the transceiver is as a Recognized Component for use in these hazardous locations, in accordance
with UL Standard 1604. The FMRC Approval is in accordance with
FMRC Standard 3611. The CSA Certification is in accordance with
CSA STD C22.2 No. 213-M1987.
FM/UL/CSA Conditions of Approval:
The transceiver is not acceptable as a stand-alone unit for use in the hazardous locations described above. It must either be mounted within
another piece of equipment which is certified for hazardous locations, or
installed within guidelines, or conditions of approval, as set forth by the
approving agencies. These conditions of approval are as follows:
1. The transceiver must be mounted within a separate enclosure which
is suitable for the intended application.
2. The antenna feedline, DC power cable and interface cable must be
routed through conduit in accordance with the National Electrical
Code.
3. Installation, operation and maintenance of the transceiver should be
in accordance with the transceiver's installation manual, and the
National Electrical Code.
4. Tampering or replacement with non-factory components may
adversely affect the safe use of the transceiver in hazardous locations, and may void the approval.
5. When installed in a Class I, Div. 2, Groups A, B, C or D hazardous
location, observe the following:
WARNING ÑEXPLOSION HAZARDÑ Do not disconnect
equipment unless power has been switched off or the area is known
to be non-hazardous.
Refer to Articles 500 through 502 of the National Electrical Code
(NFPA 70) for further information on hazardous locations and approved
Division 2 wiring methods.
MDS 05-3305A01, Rev. A
Installation and Operation Guide
iii
Notice
While every reasonable effort has been made to ensure the accuracy of
this manual, product improvements may result in minor differences
between the manual and the product shipped to you. If you have additional questions or need an exact specification for a product, please contact our Customer Service Team using the information at the back of this
guide. In addition, manual updates can often be found on the MDS Web
site at www.microwavedata.com.
FCC Warning
The 406 to 406.1 MHz band is reserved for use by distress beacons.
Since the radio described in this manual is capable of transmitting in this
band, take precautions to prevent the radio from transmitting between
406 to 406.1 MHz.
iv
Installation and Operation Guide
MDS 05-3305A01, Rev. A
1.0 GENERAL
1.1 Introduction
This guide presents installation and operating instructions for the MDS
4710A/9710A (400/900 MHz) digital radio transceivers.
These transceivers (Figure 1) are data telemetry radios designed to
operate in a point-to-multipoint environment, such as electric utility
Supervisory Control and Data Acquisition (SCADA) and distribution
automation, lottery systems, gas field automation, water and wastewater
SCADA, and on-line transaction processing applications. They use
microprocessor control and Digital Signal Processing (DSP) technology
to provide highly reliable communications even under adverse conditions.
MDS 4710A/9710A radios use continuous-phase frequency (CPFSK)
modulation with root duo-binary filtering (the sum of two
Nyquist-shaped, root-raised cosine responses). Demodulation uses a
Virterbi decoder and equalization with soft decision decoding.
Modulation and demodulation is accomplished using Digital Signal Processing (DSP). DSP adapts to differences between components from
unit to unit, and ensures consistent and repeatable performance in
ambient temperatures from Ð30 to +60 degrees Centigrade. The use of
Digital Signal Processing eliminates the fluctuations and variations in
modem operation that degrade operation of analog circuits.
The transceiver is designed for trouble-free operation with data equipment provided by other manufacturers, including Remote Terminal
Units (RTUs), flow computers, lottery terminals, automatic teller
machines, programmable logic controllers, and others.
NOTE: Some features may not be available on all radios, based on the
options purchased and based on the applicable regulatory
constraints for the region in which the radio will operate.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
Invisible place holder
SERIAL NUMBER
LABEL
LED INDICATORS (4)
EXTERNAL
INTERFACE
CONNECTOR
(DB-25)
DIAGNOSTICS
CONNECTOR (RJ-11)
13.8 VDC POWER
CONNECTOR
ANTENNA CONNECTOR
(TYPE ÒNÓ)
Figure 1. Transceiver Connectors and Indicators
1.2 Applications
Point-to-Multipoint, Multiple Address Systems (MAS)
This is the most common application of the transceiver. It consists of a
central master station and several associated remote units as shown in
Figure 2. An MAS network provides communications between a central
host computer and remote terminal units (RTUs) or other data collection
devices. The operation of the radio system is transparent to the computer
equipment.
Often, however, a radio system consists of many widely separated
remote radios. A point-to-multipoint or SCADA (Supervisory Control
and Data Acquisition) system may be a new installation for automatic,
remote monitoring of gas wells, water tank levels, electric power distribution system control and measurement, etc.
The radio system may replace a network of remote monitors currently
linked to a central location via leased telephone line. At the central
office of such a system, there is usually a large mainframe computer and
some means of switching between individual lines coming from each
remote monitor. In this type of system, there is a modulator/demodulator
(modem) at the main computer, and at each remote site, usually built
into the remote monitor itself. Since the cost of leasing a dedicated-pair
phone line is quite high, a desirable alternative may be replacing the
phone line with a radio path.
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
Invisible place holder
REMOTE RADIO
RTU
RTU
REMOTE RADIO
P W
IDIA
Ð+
13.8
VDC
Ð
RTU
P W
IDIA
Ð+
13.8
VDC
Ð
P W
IDIA
Ð+
13.8
VDC
Ð
RTU
REMOTE RADIO
REMOTE RADIO
CONTINUOUSLY
KEYED
RTU
P W
IDIA
Ð+
13.8
VDC
P W
Ð
IDIA
Ð+
13.8
VDC
Ð
REMOTE RADIO
MDS MASTER
STATION
HOST SYSTEM
Figure 2. Typical MAS Point-to-Multipoint Network
Point-to-Point System
Where permitted, the transceiver may also be used in a point-to-point
arrangement. A point-to-point system consists of just two radiosÑone
serving as a master and the other as a remoteÑas shown in Figure 3. It
provides a simplex or half-duplex communications link for the transfer
of data between two locations.
Invisible place holder
HOST
COMPUTER
MASTER
RTU
REMOTE
Figure 3. Typical Point-to-Point Link
Continuously Keyed versus Switched Carrier Operation
The keying behavior of the master station can be used to describe an
MAS system.
Continuously Keyed operation means the master station transmitter is
always keyed and an RF carrier is always present, even when there is no
data to send. The master station is always simultaneously transmitting
and continuously listening. Different frequencies must be used for
transmit and receive. This is the method used in many MAS systems,
and is shown in Figure 2. This is useful for high-speed polling applications.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
NOTE: 4710A/9710A remotes do not support full-duplex operation.
Switched Carrier operation is a half-duplex mode of operation where
the master station transmitter is keyed to send data and unkeyed to
receive.
Single Frequency (Simplex) Operation
Single frequency operation (also known as simplex) is a special case of
switched carrier operation. Single frequency operation is automatically
selected whenever the transmit and receive frequencies are set to the
same value. Note that data turn-around times are increased when a
single frequency configuration is used.
1.3 Model Number Codes
The radio model number is printed on the end of the radio enclosure, and
provides key information about how the radio was configured when it
was shipped from the factory. See Figure 4 and Figure 5 for an explanation of the model number characters.
Invisible place holder
THIS INFORMATION IS
SUBJECT TO
CHANGE.
DO NOT USE FOR
PRODUCT ORDERING.
RECEIVE FREQUENCY
(A) 380-400 MHz*
TRANSMIT FREQUENCY
(B) 400-420 MHz
(1) 380-400 MHz
(C) 420-450 MHz
(2) 400-420 MHz
(D) 450-480 MHz
(3) 420-450 MHz
INPUT VOLTAGE
(E) 480-512 MHz
1= 10.5 to 16 VDC
(L) 406-430 MHz** (4) 450-480 MHz**
SAFETY
DIAGNOSTICS
AGENCY N= N/A
OPERATION
0= NONE
N=
N/A
(F) CSA/FM/UL
X= Base/Remote
1= Non-Intrusive
F= FCC/IC
4710A
MOUNTING BRACKETS
FEATURES
MODEM
A= Standard
0=
Full
B= 9600 BPS
BANDWIDTH
B= None
MODE
C= 19200 (25kHz) 1= 12.5 KHz
N= Non-redundant
2= 25 KHz (19.2 Kbps)
*Not Available with FCC or IC
** Only available with RX option
Figure 4. 4710A Model Number Codes
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
Invisible place holder
THIS INFORMATION IS
SUBJECT TO
CHANGE.
DO NOT USE FOR
PRODUCT ORDERING.
RECEIVE FREQUENCY
(A) 800-860 MHz*
(B) 860-900 MHz
TRANSMIT FREQUENCY
(C) 900-960 MHz (1) 800-880 MHz
INPUT VOLTAGE
(2)
880-960 MHz
1= 10.5 to 16 VDC
SAFETY
DIAGNOSTICS
AGENCY N= N/A
OPERATION
0= NONE
N=
N/A
(F) CSA/FM/UL
X= Base/Remote
1= Non-Intrusive
F= FCC/IC
9710A
MOUNTING BRACKETS
FEATURES
MODEM
A= Standard
B= 9600 BPS
BANDWIDTH 0= Full
B= None
MODE
C= 19200 (25kHz) 1= 12.5 KHz
N= Non-redundant
2= 25 KHz (19.2 Kbps)
*Not Available with FCC or IC
Figure 5. 9710A Model Number Codes
1.4 Accessories
The transceiver can be used with one or more of the accessories listed in
Table 1. Contact Microwave Data Systems for ordering information.
Table 1. MDS 4710A/9710A Optional Accessories
MDS 05-3305A01, Rev. A
Accessory
Description
MDS P/N
Hand-Held Terminal
Kit (HHT)
Terminal that plugs into the radio for
programming, diagnostics & control.
Includes carrying case and cable set.
02-1501A01
RTU Simulator
Test unit that simulates data from a
remote terminal unit. Comes with
polling software that runs on a PC.
Useful for testing radio operation.
03-2512A01
Order Wire Module
External device that allows temporary
voice communication. Useful during
setup & testing of the radio system.
02-1297A01
Order Wire Handset
Used with Order Wire Module (above).
12-1307A01
RJ-11 to DB-9 adapter
Used to connect a PC to the radioÕs
DIAG. port
03-3246A01
EIA-232 to EIA-422
Converter Assembly
External adapter plug that converts the
radioÕs DATA INTERFACE connector
to EIA-422 compatible signaling.
03-2358A01
TTL Converter
Assembly
External adapter plug that converts the
radioÕs DATA INTERFACE connector
to TTL compatible signaling.
03-2223A01
Radio Configuration
Software
Provides diagnostics of the transceiver
(Windows-based PC required.)
03-3156A01
MDS 4710A/9710A Installation and Operation Guide
2.0 GLOSSARY OF TERMS
If you are new to digital radio systems, some of the terms used in this
guide may be unfamiliar. The following glossary explains many of these
terms and will prove helpful in understanding the operation of the transceiver.
Active MessagingÑThis is a mode of diagnostic gathering that may
interrupt SCADA system polling communications (contrast with passive messaging). Active (or intrusive) messaging is much faster than
passive messaging because it is not dependent upon the RTU polling
cycle.
Antenna System GainÑA figure, normally expressed in dB, representing the power increase resulting from the use of a gain-type antenna.
System losses (from the feedline and coaxial connectors, for example)
are subtracted from this figure to calculate the total antenna system gain.
BitÑThe smallest unit of digital data, often represented by a one or a
zero. Eight bits (plus start, stop, and parity bits) usually comprise a byte.
Bits-per-secondÑSee BPS.
BPSÑBits-per-second. A measure of the information transfer rate of
digital data across a communication channel.
ByteÑA string of digital data usually made up of eight data bits and
start, stop and parity bits.
Decibel (dB)ÑA measure computed from the ratio between two signal
levels. Frequently used to express the gain (or loss) of a system.
Data Circuit-terminating EquipmentÑSee DCE.
Data Communications EquipmentÑSee DCE.
Data Terminal EquipmentÑSee DTE.
dBiÑDecibels referenced to an ÒidealÓ isotropic radiator in free space.
Frequently used to express antenna gain.
dBmÑDecibels referenced to one milliwatt. An absolute unit used to
measure signal power, as in transmitter power output, or received signal
strength.
DCEÑData Circuit-terminating Equipment (or Data Communications
Equipment). In data communications terminology, this is the ÒmodemÓ
side of a computer-to-modem connection. The MDS 4710A/9710A is a
DCE device.
Digital Signal ProcessingÑSee DSP.
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
DSPÑDigital Signal Processing. In the MDS 4710A/9710A transceiver, the DSP circuitry is responsible for the most critical real-time
tasks; primarily modulation, demodulation, and servicing of the data
port.
DTEÑData Terminal Equipment. A device that provides data in the
form of digital signals at its output. Connects to the DCE device.
EqualizationÑThe process of reducing the effects of amplitude, frequency or phase distortion with compensating networks.
Fade MarginÑThe greatest tolerable reduction in average received
signal strength that will be anticipated under most conditions. Provides
an allowance for reduced signal strength due to multipath, slight antenna
movement or changing atmospheric losses. A fade margin of 20 to 30
dB is usually sufficient in most systems.
FrameÑA segment of data that adheres to a specific data protocol and
contains definite start and end points. It provides a method of synchronizing transmissions.
Hardware Flow ControlÑA transceiver feature used to prevent data
buffer overruns when handling high-speed data from the RTU or PLC.
When the buffer approaches overflow, the radio drops the clear-to-send
(CTS) line, which instructs the RTU or PLC to delay further transmission until CTS again returns to the high state.
Host ComputerÑThe computer installed at the master station site,
which controls the collection of data from one or more remote sites.
Intrusive DiagnosticsÑA mode of remote diagnostics that queries and
commands radios in a network with an impact on the delivery of the
system ÒpayloadÓ data. See Active messaging.
LatencyÑThe delay (usually expressed in milliseconds) between when
data is applied to TXD (Pin 2) at one radio, until it appears at RXD
(Pin 3) at the other radio.
MASÑMultiple Address System. A radio system where a central
master station communicates with several remote stations for the purpose of gathering telemetry data.
Master (Station)ÑRadio which is connected to the host computer. It is
the point at which polling enters the network.
MCUÑMicrocontroller Unit. This is the processor responsible for controlling system start-up, synthesizer loading, and key-up control.
Microcontroller UnitÑSee MCU.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
Multiple Address SystemÑSee MAS.
Network-Wide DiagnosticsÑAn advanced method of controlling and
interrogating MDS radios in a radio network.
Non-intrusive diagnosticsÑSee Passive messaging.
Passive messagingÑThis is a mode of diagnostic gathering that does
not interrupt SCADA system polling communications. Diagnostic data
is collected non-intrusively over a period of time; polling messages are
carried with SCADA system data (contrast with active messaging).
Payload dataÑThis is the applicationÕs user communication data
which is sent over the radio network. It is the transfer of payload data
that is the primary purpose of the radio communications network.
Point-Multipoint SystemÑA radio communications network or
system designed with a central control station that exchanges data with
a number of remote locations equipped with terminal equipment.
PollÑA request for data issued from the host computer (or master PLC)
to a remote radio.
PLCÑProgrammable Logic Controller. A dedicated microprocessor
configured for a specific application with discrete inputs and outputs. It
can serve as a host or as an RTU.
Programmable Logic ControllerÑSee PLC.
Remote (Station)ÑA radio in a network that communicates with an
associated master station.
Remote Terminal UnitÑSee RTU.
Redundant OperationÑA station arrangement where two transceivers
and two power supplies are available for operation, with automatic
switchover in case of a failure.
RTUÑRemote Terminal Unit. A data collection device installed at a
remote radio site. An internal RTU simulator is provided with
4710/9710 radios to isolate faults to either the external RTU or the radio.
SCADAÑSupervisory Control And Data Acquisition. An overall term
for the functions commonly provided through an MAS radio system.
Standing Wave RatioÑSee SWR.
Supervisory Control And Data AcquisitionÑSee SCADA.
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
SWRÑStanding Wave Ratio. A parameter related to the ratio between
forward transmitter power and the reflected power from the antenna
system. As a general guideline, reflected power should not exceed 10%
of the forward power (≈ 2:1 SWR).
3.0 INSTALLATION
There are three main requirements for installing the transceiverÑadequate and stable primary power, a good antenna system, and the correct
data connections between the transceiver and the data device. Figure 6
shows a typical remote station arrangement.
Invisible place holder
REMOTE TERMINAL
UNIT
ANTENNA SYSTEM
RADIO
TRANSCEIVER
13.8 VDC
POWER
CABLE
LOW-LOSS FEEDLINE
13.8 VDC
2.5 A (Minimum)
POWER SUPPLY
Figure 6. Typical Remote Station Arrangement
3.1 Installation Steps
Below are the basic steps for installing the transceiver. In most cases,
these steps alone are sufficient to complete the installation. More
detailed explanations appear at the end of these steps.
1. Mount the transceiver to a stable surface using the brackets supplied
with the radio.
2. Install the antenna and antenna feedline for the station. Preset directional antennas in the desired direction.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
3. Connect the data equipment to the transceiverÕs DATA INTERFACE
connector. Use only the required pins for the applicationÑDo not
use a fully pinned (25 conductor) cable. Basic applications may
require only the use of Pin 2 (transmit dataÑTXD), Pin 3 (Received
DataÑRXD) and Pin 7 (signal ground). The radio can be keyed
with the use of the DATAKEY command.
Additional connections may be required for some installations.
Refer to the complete list of pin functions provided in Table 4 on
page 14.
4. Measure and install the primary power for the radio. The red wire on
the power cable is the positive lead; the black is negative.
NOTE: Use the radio in negative ground systems only.
5. Set the radio conÞguration. The transceiver is designed for quick
installation with a minimum of software conÞguration required in
most cases. The selections that must be made for new installations
are:
¥ Transmit frequency
¥ Receive frequency
The operating frequencies are not set at the factory unless they were
speciÞed at the time of order. Determine the transmit and receive
frequencies to be used, and follow the steps below to program them.
6. Connect a hand-held terminal (HHT) to the DIAG. connector. When
the HHT beeps, press ENTER to receive the ready Ò>Ó prompt.
a. Set the operating frequencies using the TX xxx.xxxx (transmit) and
RX xxx.xxxx (receive) commands.
Press ENTER after each command. After programming, the HHT
reads PROGRAMMED OK to indicate successful entry.
10
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
3.2 Transceiver Mounting
Figure 7 shows the mounting dimensions of the transceiver.
Invisible place holder
AAA
AAA
AAA
AAA
AA
AA
7.25"
184 mm
1 .7 5 "
4 .4 4 C M
2.75"
70 mm
ALTERNATE
POSITION
6.63"
168 mm
8.5"
216 mm
2.25"
57 mm
2.0"
50 mm
5.625"
143 mm
AAAAAAAAA
Figure 7. Transceiver Mounting Dimensions
3.3 Antennas and Feedlines
Antennas
The transceiver can be used with a number of antennas. The exact style
depends on the physical size and layout of the radio system. A directional Yagi (Figure 8) or corner reflector antenna is generally recommended at remote sites to minimize interference to and from other users.
Antennas of this type are available from several manufacturers.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
11
Invisible place holder
Figure 8. Typical Yagi Antenna (mounted to mast)
Feedlines
The selection of antenna feedline is very important. Poor quality cables
should be avoided as they will result in power losses that may reduce the
range and reliability of the radio system.
Table 2 and Table 3 show the losses that will occur when using various
lengths and types of cable at 400 and 960 MHz. Regardless of the type
of cable used, it should be kept as short as possible to minimize signal
loss.
Table 2. Length vs. Loss in Coaxial Cables at 400 MHz
10 Feet
50 Feet
100 Feet
500 Feet
(3.05 Meters)
(15.24 Meters)
(30.48 Meters)
(152.4 Meters)
RG-8A/U
0.51dB
2.53 dB
5.07 dB
25.35 dB
1/2 inch HELIAX
0.12 dB
0.76 dB
1.51 dB
7.55 dB
7/8 inch HELIAX
0.08 dB
0.42 dB
0.83 dB
4.15 dB
1-1/4 inch HELIAX
0.06 dB
0.31 dB
0.62 dB
3.10 dB
1-5/8 inch HELIAX
0.05 dB
0.26 dB
0.52 dB
2.60 dB
Cable Type
Table 3. Length vs. Loss in Coaxial Cables at 960 MHz
10 Feet
50 Feet
100 Feet
500 Feet
(3.05 Meters)
(15.24 Meters)
(30.48 Meters)
(152.4 Meters)
RG-8A/U
0.85 dB
4.27 dB
8.54 dB
42.70 dB
1/2 inch HELIAX
0.23 dB
1.15 dB
2.29 dB
11.45 dB
7/8 inch HELIAX
0.13 dB
0.64 dB
1.28 dB
6.40 dB
1-1/4 inch HELIAX
0.10 dB
0.48 dB
0.95 dB
4.75 dB
1-5/8 inch HELIAX
0.08 dB
0.40 dB
0.80 dB
4.00 dB
Cable Type
12
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
3.4 Power Connection
The transceiver can be operated from any well-filtered 10.5 to 16 Vdc
power source. The power supply should be capable of providing at least
2.5 amperes of continuous current.
The red wire on the power cable is the positive lead; the black is negative.
NOTE: The radio is designed for use only in negative ground systems.
3.5 Data Interface Connections
The transceiverÕs DATA INTERFACE connector is used to connect the
transceiver to an external DTE data terminal that supports the EIA-232
(formally RS-232) format. The transceiver supports asynchronous data
rates of up to 38400 bps. The data rate at the DATA INTERFACE connector
may differ from the data rate used over the air.
Table 4 lists each pin on the DATA INTERFACE connector and describes
its function.
CAUTION
USE
ONLY REQUIRED
PINS
Do not use a 25 wire (fully pinned) cable for connection to the DATA
INTERFACE connector. Use only the required pins for the application.
Damage may result if improper connections are made. Typical applications require the use of only Pins 1 through 8 for EIA-232 signaling.
3.6 Using the RadioÕs Sleep Mode
In some installations, such as at solar-powered sites, it may be necessary
to keep the transceiverÕs power consumption to an absolute minimum.
This can be accomplished using the Sleep Mode. In this mode, power
consumption is reduced to less than 16 milliamperes (nominal).
Sleep mode can be enabled under RTU control by asserting a ground (or
RS-232 low) on Pin 12 of the radioÕs DATA INTERFACE connector.
When Pin 12 is opened (or an RS-232 high is asserted), the radio will be
ready to receive data within 75 milliseconds.
All normal functions are suspended while the radio is in sleep mode. The
will be off, except for a quick flash every five seconds.
PWR LED
System Example
The following example describes Sleep Mode implementation in a typical system. Using this information, you should be able to configure a
system that will meet your own particular needs.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
13
Example:
Suppose you need communications to each remote site only
once per hour. Program the RTU to raise an RS-232 line once
each hour (DTR for example) and wait for a poll and response
before lowering it again. Connect this line to Pin 12 of the
radioÕs DATA INTERFACE connector. This will allow each RTU to
be polled once per hour with a significant savings in power consumption.
Table 4. DATA INTERFACE Connector Pinouts
14
Pin
Number
Input/
Output
--
Protective Ground. Connects to ground (negative supply
potential) on the radioÕs PC board and chassis.
IN
TXDÑTransmitted Data. Accepts TX data from the
connected device.
OUT
RXDÑReceived Data. Outputs received data to the
connected device.
IN
RTSÑRequest-to-Send Input. Keys the transmitter when
RTS is at logic high.
OUT
CTSÑClear-to-Send Output. Goes ÒhighÓ after the
programmed CTS delay time has elapsed (DCE) or keys
an attached radio when RF data arrives (CTS KEY).
OUT
DSRÑData Set Ready. Provides a +6 Vdc DSR signal
through a 2.5 kΩ resistor.
--
Signal Ground. Connects to ground (negative supply
potential) at radioÕs PC board.
OUT
DCDÑData Carrier Detect. Goes ÒhighÓ when the modem
detects a data carrier from the master station.
IN
Transmit Audio Input. Connects to the audio output of an
external (AFSK) modem. The input impedance is 600 Ω.
Use Pin 7 for the modemÕs return lead.
10
OUT
RUSÑReceiver Unsquelched Sensor. Not used in most
installations, but is available as a convenience. Provides
+8 Vdc through a 1 kΩ resistor whenever the receiver
squelch is open, and drops to less than 1 Vdc when the
squelch is closed.
11
OUT
Receive Audio Output. Connects to the audio input of an
external (AFSK) modem. The output impedance is 600 Ω,
and the level is factory set to suit most installations. Use
Pin 7 for the modemÕs return lead.
12
IN
Radio Inhibit (Sleep). A ground on this pin places the
radio into the ÒsleepÓ mode. It turns off most circuits in the
radio, including transmit, receive, modem and diagnostic
functions. This allows for greatly reduced power
consumption, yet preserves the radioÕs ability to be quickly
brought online.
13
--
Do not connectÑReserved for future use.
14
IN
PTTÑPush to Talk. This line is used to key the radio with
an active-high signal of +5 Vdc.
Pin Description
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
Table 4. DATA INTERFACE Connector Pinouts (Continued)
Pin
Number
Input/
Output
15
--
.Remote RTU Reset. Do not connect. Reserved for future
use.
16
IN
PTTÑPush to Talk. This line is used to key the radio with
an active-low signal of 0 Vdc.
17
--
Do not connectÑReserved for future use.
18
IN/OUT
Accessory Power. Unregulated Input/Output. Provides a
source of input power for low current accessories.
Excessive drain on this connection will trip self-resetting
fuse F1 on the transceiver PC board. The voltage at this
pin will match the input voltage to the transceiver.
19
OUT
9.9 Vdc Regulated Output. Provides a source of
regulated voltage at 100 mA for low power accessories.
20
--
Do not connectÑReserved for future use.
21
OUT
RSSIÑReceived Signal Strength Indication. A DC
voltmeter may be connected to this pin to read the relative
strength of the incoming signal. Figure 9 is a chart showing
RSSI vs. DC voltage.
22
--
Do not connectÑReserved for future use.
23
IN
Diagnostic Channel Enable. A ground on this pin causes
the radioÕs microcontroller to open the DB-25 DATA
INTERFACE for diagnostics and control instead of the
normal RJ-11 DIAG. connection.
24
--
Do not connectÑReserved for future use.
25
OUT
Alarm. A logic low (less than 0.5 volts) on this pin indicates
normal operation. A logic high (greater than 4 volts)
indicates that some alarm condition is present. This pin
can be used as an alarm output, provided the internal
series resistance of 1 kΩ is considered.
Pin Description
Invisible place holder
4.0 OPERATION
In-service operation of the transceiver is completely automatic. Once
the unit has been properly installed and configured, operator actions are
limited to observing the front panel LED status indicators for proper
operation.
If all parameters are correctly set, operation of the radio can be started
by following these steps:
1. Apply DC power to the transceiver.
2. Observe the LED status panel for the proper indications (Table 5).
3. If not done earlier, reÞne the antenna heading of the station to maximize the received signal strength (RSSI) from the master station.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
15
Use the RSSI command from an HHT connected to the radioÕs DIAG.
connector.ÑSee Section 5.0, TRANSCEIVER PROGRAMMING on
page 17. This can also be done with a DC voltmeter as described in
Section 4.2, RSSI Measurement (page 16).
4.1 LED Indicators
Table 5 describes the function of each status LED.
PWR
DCD
TXD
RXD
Table 5. LED Status Indicators
LED Name
PWR
Description
¥ ContinuousÑPower is applied to the radio, no problems detected.
¥ Rapid flash (five times per second)ÑFault indication.
¥ Flashing once every 5 secondsÑRadio is in Sleep mode.
DCD
¥ FlashingÑIndicates the radio is receiving intermittent data frames.
¥ ContinuousÑRadio is receiving a data signal from a continuously
keyed radio.
TXD
An EIA-232 mark signal is being received at the DATA INTERFACE
connector.
RXD
An EIA-232 mark signal is being sent out from the DATA INTERFACE
connector.
4.2 RSSI Measurement
As an alternative to using an HHT, the radioÕs received signal strength
(RSSI) may be read with a DC voltmeter connected to Pin 21 of the DATA
INTERFACE connector. Figure 9 shows the relationship between
received signal level and the DC voltage on Pin 21 of the DATA INTERFACE connector. (Note: Readings are not accurate for incoming signal
strengths above Ð50 dBm.)
16
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
4.5
3.5
2.5
Ð5
Ð7
Ð9
Ð1
10
+ DC VOLTS (PIN 21)
Invisible place holder
5.0
SIGNAL LEVEL (dBm)
Figure 9. RSSI vs. Vdc (Typical)
5.0 TRANSCEIVER PROGRAMMING
Programming and control of the transceiver is performed through the
radioÕs RJ-11 DIAG. (Diagnostics) connector with an MDS Hand-Held
Terminal (MDS P/N 02-1501A01). This section contains a reference
chart (Table 7) and detailed descriptions for each user command.
NOTE: In addition to HHT control, Windows-based software is available (MDS P/N 03-3156A01) to allow diagnostics and
programming using a personal computer. An installation
booklet and on-line instructions are included with the software. Contact MDS for ordering information.
5.1 Hand-Held Terminal Connection & Startup
This section gives basic information for connecting and using the MDS
Hand-Held Terminal. For more information about the terminal, refer
also to the instructions included with each HHT kit.
The steps below assume that the HHT has been configured for use with
the transceiver (80 character screen display). If the HHT was previously
used with a different model transceiver, or if its default settings have
been changed, refer to Section 5.2, Hand-Held Terminal Setup (page 18)
for setup details.
Follow these steps to connect the HHT:
1. Connect the HHTÕs coiled cord to the DIAG. (RJ-11) jack on the radio
as shown in Figure 10. This automatically places the radio into the
control and programming mode.
As an alternative, the DATA INTERFACE (DB-25) connector may be
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
17
used for programming instead of the DIAG. jack. With this arrangement, Pin 23 of the HHT cable must be grounded to enable the diagnostic channel. (See Table 4 on page 14.)
2. When the HHT is connected, it runs through a brief self-check,
ending with a beep. After the beep, press ENTER to receive the
ready Ò>Ó prompt.
Invisible place holder
13.8
VDC
Ð
ANTE
NNA
F5
F4
F3
F2
F1
CTR
SHIF
Ð
ENTE
ACE
ESC SP
SP
BK
Figure 10. Hand-Held Terminal Connected to the Transceiver
5.2 Hand-Held Terminal Setup
The following is a set of instructions for re-initializing an HHT for use
with the transceiver. These steps may be required if the HHT was previously used with a different radio, or if the HHT default settings have
been inadvertently altered.
1. Plug the HHT into the DIAG. connector. Enable the setup mode by
pressing the SHIFT , CTRL and SPACE keys in sequence. The display
shown in Figure 11 appears.
18
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
Invisible place holder
Figure 11. HHT Setup Display
2. The Þrst of 15 menu items is displayed. Settings are reviewed by
pressing the NEXT function controlled by the E key. Parameter settings are changed by pressing the ROLL function controlled by the
A key.
3. Set up the HHT as listed in Table 6.
Table 6. HHT Operational Settings
Parameter
Setting
Parameter
Setting
Re-init HT
NO
Scroll On
33rd
Baud Rate
9600
Cursor
ON
Comm bits
8,1,n
CRLF for CR
OFF
Parity Error
OFF
Self Test
FAST
Key Repeat
OFF
Key Beep
ON
Echo
OFF
Screen Size
80
Shift Keys
YES
Menu Mode
LONG
Ctl Chars
PROCS
5.3 Keyboard Commands
Table 7 is a reference chart of software commands for the transceiver.
Programmable information is shown in brackets [ ] following the command name. See Section 5.4, Detailed Command Descriptions (page 22)
for detailed command descriptions.
Entering Commands
To enter a command, type the command, followed by an ENTER keystroke. For programming commands, the command is followed by
SPACE and the appropriate information or values, then ENTER .
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
19
Here are some additional points to remember when using the HHT:
¥ Use the SHIFT key to access numbers; press again to return to letter
mode.
¥ Use the ESC/BKSP key to edit information or commands entries.
¥ The flashing square cursor ( ) indicates that letter mode is
selected.
¥ The flashing superscript rectangular cursor ( ) indicates that
number mode is selected.
Error Messages
Listed below are some possible error messages encountered when using
the HHT:
UNKNOWN COMMANDÑThe command was not recognized. Refer to the
command description for command usage information.
INCORRECT ENTRYÑThe
command format or its associated values were
not valid. Refer to the command description for command usage information.
COMMAND FAILEDÑThe command was unable to successfully complete.
This is a possible internal software problem.
NOT PROGRAMMEDÑSoftware
was unable to program the internal radio
memory or the requested item was not programmed.This is a serious
internal radio error. Contact MDS.
TEXT TOO LONGÑResponse to OWN or OWM command when too many
characters have been entered. Refer to the command description for
command usage information.
NOT AVAILABLEÑThe entered command or parameter was valid, but it
referred to a currently unavailable choice. Refer to the command
description for command usage information.
ACCESS DENIEDÑThe command is unavailable to the user. Refer to the
command descriptions for command information.
EEPROM FAILUREÑ The INIT command was unable to write to EEPROM.
This is a serious internal radio error. Contact MDS.
20
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
Table 7. Command summary
Command name
MDS 05-3305A01, Rev. A
Function
AMASK [0000 0000ÐFFFF
FFFF] Details page 23
Set or display hex code identifying which events
trigger an alarm.
ASENSE [HI/LO] Details
page 24
Set or display the state of the alarm output signal
to ACTIVE HI or ACTIVE LO.
BAUD [xxxxx abc] Details
page 24
Set or display the DATA INTERFACE data rate
and control bits.
BUFF [ON, OFF] Details
page 24
Enables or disables the internal radio data buffer.
CTS [0Ð255] Details page
25
Set or display the Clear-to-Send delay in seconds.
CKEY [ONÐOFF] Details
page 25
Enables or disables the continuously keyed
mode. Note: Remotes cannot receive when
keyed.
DATAKEY [ON, OFF]
Details page 25
Toggles between key-on-data and key-on-RTS.
DKEY Details page 26
Dekey the radio (transmitter OFF). This is
generally a radio test command.
DLINK [ON/OFF/xxxx]
Details page 26
Configures local diagnostic link protocol.
DMGAP [xx] Details page
26
(diagnostics) Sets the amount of time to wait after
the receipt of a character before interpreting the
next received character as the start of a new
message.
DTYPE [NODE/ROOT]
Details page 26
(diagnostics) Sets up a radio as a root or node
radio.
DUMP Details page 26
Display all programmable settings.
HREV Details page 26
Display the Hardware Revision level.
INIT Details page 27
Set radio parameters to factory defaults.
INIT [4710/9710] Details
page 27
Configure radio for use without P-20 chassis.
Restores certain transceiver defaults before using
the INIT x720 command.
INIT [4720/9720] Details
page 27
Configure radio for use with P-20 chassis.
KEY Details page 27
Key the radio (transmitter ON). This is generally a
radio test command.
MODEL Details page 27
Display the model number of the radio.
MODEM [xxxx, NONE]
Details page 28
Set the modem characteristics of the radio.
OWM [XXX...] Details page
28
Set or display the ownerÕs message.
OWN [XXX...] Details page
28
Set or display the ownerÕs name.
PTT [0Ð255] Details page
28
Set or display the Push-to-Talk delay in
milliseconds.
MDS 4710A/9710A Installation and Operation Guide
21
Table 7. Command summary (Continued)
Command name
Function
PWR [20Ð37] Details page
28
Set or display the transmit power setting.
RSSI Details page 28
Display the Received Signal Strength Indication.
RTU [ON/OFF/0-80] Details
page 29
Re-enables or disables the radioÕs internal RTU
simulator and sets the RTU address.
RX [xxx.xxxx] Details page
29
Set or display receiver frequency.
RXTOT [NONE, 1-255]
Details page 29
Set or display the value of the receive time-out
timer.
SCD [0-255] Details page
29
Set or display the Soft-carrier Dekey delay in
milliseconds.
SER Details page 29
Display the radio serial number.
SHOW [DC, PORT, PWR]
Details page 30
Display the DC voltages, diagnostics port, and
transmit power level.
SREV Details page 30
Display the Software Revision Level.
STAT Details page 30
Display radio status and alarms.
TEMP Details page 30
Display the internal temperature of the radio in
degrees C.
TOT [1-255, ON, OFF]
Details page 31
Set or display the Time-out Timer delay in
milliseconds.
TX [xxx.xxxx] Details page
31
Set or display the transmit frequency.
UNIT [10000...65000]
Details page 31
Set or display the transceiverÕs unit address.
5.4 Detailed Command Descriptions
The only critical commands for most applications are transmit and
receive frequencies (RX xxx.xxxx, TX xxx.xxxx). However, proper use of
the additional commands allows you to tailor the transceiver for a specific use, or conduct basic diagnostics on the radio. This section gives
more detailed information for the user commands previously listed in
Table 7 (page 21).
In many cases, the commands shown here can be used in two ways.
First, you can type only the command name to view the currently programmed data. Secondly, you can set or change the existing data by
typing the command, followed by a space, and then the desired entry. In
the list below, allowable programming variables, if any, are shown in
brackets following the command name.
22
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
AMASK [0000 0000ÐFFFF FFFF]
The AMASK command displays or sets which events cause the alarm
output signal to be active. Normally, the mask is FFFF FFFF, meaning that
any of the 32 possible events will activate the alarm output signal.
Entering the AMASK command alone displays the current setting of alarm
events in hexadecimal format.
Entering the AMASK command followed by an eight-digit hexadecimal
number reprograms the specified events to trigger an alarm.
The eight-digit hexadecimal number used as the command parameter is
used to classify up to 32 events as alarm triggers, or disable alarm notification for an event. (See Table 8 below for a list of events.) The hex
value for the mask corresponds to the hex value for the STAT command
(page 30). Each bit that is a Ô1Õ identifies the associated alarm condition
as a major alarm. Each bit that is a Ô0Õ disables major alarm notification
for that condition. If both the major and minor alarm bits are set to Ô0Õ
for that condition, alarm notification is entirely disabled. For more information on configuring the alarm response, contact Microwave Data Systems and request Application Bulletin 98-002.
Table 8. Text messages of alarm event codes
Event Number
MDS 05-3305A01, Rev. A
Text Message
01
Hardware mismatch
02
Model number not programmed
03
Authorization fault
04
Synthesizer out-of-lock
07
Voltage regulator fault detected
08
Radio not calibrated
09
DSP download fault
10
EEPROM write failure
11
Checksum fault
12
Receiver time-out
16
Unit address not programmed
17
Data parity error
18
Data framing error
20
Configuration error
25
6V regulator output not in valid range
26
DC input power is not in valid range
31
Internal Temperature not in valid range
MDS 4710A/9710A Installation and Operation Guide
23
ASENSE [HI/LO]
The ASENSE command sets or displays the sense of the alarm output at
Pin 25 of the DATA INTERFACE connector.
Entering the ASENSE command alone shows whether the alarm output is
active high or low. Entering the ASENSE command followed by HI or LO
resets the alarm output to active high or low.
BAUD [xxxxx abc]
This command sets (or displays) the communication attributes for the
It has no effect on the RJ-11 DIAG. port.
DATA INTERFACE port.
The first parameter (xxxxx) is baud rate. Baud rate is specified in
bits-per-second (bps) and must be one of the following speeds: 110, 300,
1200, 2400, 4800, 9600, 19200, or 38400.
The second parameter of the BAUD command (abc) is a three-character
block indicating how the data is encoded:
a = Data bits (7 or 8)
b = Parity (N for None,
c = Stop bits (1 or 2)
O for Odd, E for Even)
The factory default setting is 19200 baud, 8 data bits, no parity, 1 stop
bit (Example: 19200 8N1).
NOTE: 7N1, 8O2, and 8E2 are invalid communication settings and are
not supported by the transceiver.
BUFF [ON, OFF]
This command sets or displays the received data handling mode of the
radio. The command parameter is either ON or OFF. The default is ON.
The setting of this parameter affects the timing of how received RF data
is sent out the INTERFACE connector. Outgoing (transmitted) data is not
affected by this setting.
If data buffering is OFF, the radio operates with the lowest possible
average latency. Data bytes are thus sent out the INTERFACE port as soon
as an incoming RF data frame is disassembled. Average and typical
latency will both be below 10 ms, but idle character gaps may be introduced into the outgoing data flow.
If data buffering is ON, the radio operates in seamless mode. Data bytes
will be sent over the air as quickly as possible, but the receiver buffers
(stores) the data until enough bytes have arrived to cover worst-case
gaps in transmission. This mode of operation is required for protocols
such as MODBUSª that do not allow gaps in their data transmission.
24
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
Note that seamless mode (BUFF ON) is intended only for applications
where the transmitterÕs baud rate is greater than or equal to the
receiverÕs baud rate. Enforcement of this rule is left up to the user.
CKEY [ONÐOFF]
The CKEY command enables or disables the continuously-keyed function of the radio. When CKEY is set to ON, the radio is continuously
keyed.
CTS [0Ð255]
The CTS (clear-to-send) command selects or displays the timer value
associated with the CTS line response. The command parameter ranges
from 0 to 255 milliseconds.
For DCE operation, the timer specifies how long to wait after the RTS
line goes high, before the radio asserts CTS and the DTE can transmit
the data. A CTS value of zero keys the radio and asserts the CTS line
immediately after the RTS line goes high.
For CTS Key operation (see DEVICE command), the timer specifies how
long to wait after asserting the CTS, before sending data out the DATA
INTERFACE port. A timer value of zero means that data will be sent out
the data port without imposing a key-up delay. (Other delays may be
present based on selected radio operating parameters.)
DATAKEY [ON, OFF]
The DATAKEY command enables or disables the ability of the radio to key
the transmitter as data is received at the DATA INTERFACE connector.
Asserting RTS keys the radio regardless of this command setting.
If DATAKEY is set to ON, the radio will key when a full data-character is
received at the transceiverÕs DATA INTERFACE connector. If DATAKEY is
set to OFF, the radio needs to be keyed by asserting either the RTS or
PTT signal or with the CKEY or KEY command.
DEVICE [DCE, CTS KEY]
The DEVICE command controls or displays the device behavior of the
radio. The command parameter is either DCE or CTS KEY.
The default selection is DCE. In this mode, CTS will go high following
RTS, subject to the CTS programmable delay time. If the DATAKEY command is set to ON, keying can be stimulated by the input of characters at
the data port. Hardware flow control is implemented by signaling the
CTS line if data arrives faster than it can be buffered and transmitted.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
25
If CTS KEY is selected, the radio is assumed to be controlling another
radio. The RTS line is ignored and the CTS line is used as a keyline control for the other radio. CTS is asserted immediately following the
receipt of RF data, but data will not be sent out the DATA INTERFACE port
until after the CTS programmable delay time has expired. (This gives
the other radio time to key.)
DKEY
This command deactivates the transmitter after it has been keyed with
the KEY command.
DLINK [ON/OFF/xxxx]
This command is used to configure the local diagnostic link protocol
used in network-wide diagnostics.
Entering DLINK ON enables the diagnostic link. Entering DLINK OFF disables the diagnostic link.
To change the diagnostic link, enter DLINK followed by one of the following baud rates: 1200, 2400, 4800, 9600, 19200 (default).
DMGAP [xx]
The DMGAP command sets the amount of time in milliseconds to wait
after the receipt of a character before interpreting the next received character as the start of a new message. When data port baud rates are slow,
the gap between characters within a poll may be so long that the radio
interprets the next character as the start of a new poll. When diagnostics
is being performed using passive messaging (see Performing Network-Wide Remote Diagnostics on page 37), this command may be used
to change this behavior.
DTYPE [NODE/ROOT]
This command establishes the local radio as a root radio or node radio
for network-wide diagnostics. Entering DTYPE NODE configures the
radio as a node radio. Entering DTYPE ROOT configures the radio as a root
radio. Entering the DTYPE command alone displays the current setting.
See ÒPerforming Network-Wide Remote DiagnosticsÓ on page 37.
DUMP
This command displays all the programmed settings with this one command. The HHT display is too small to list all the command settings at
one time. Therefore, this command is most useful if the command is
issued from a computer or full-screen terminal.
HREV
This command displays the transceiverÕs hardware revision level.
26
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
INIT
The INIT command is used to re-initialize the radioÕs operating parameters to the factory defaults. This may be helpful when trying to resolve
configuration problems that may have resulted from the entry of one or
more improper command settings. If you are unsure of which command
setting may have caused the problem, this command allows you to get
back to a known working state. The following changes to the radio are
made when INIT is entered:
¥
¥
¥
¥
¥
¥
¥
is set to 0
DATAKEY is set to ON
DEVICE is set to DCE
PTT is set to 0
SCD is set to 0
TOT is set to 30 seconds and set to ON
PWR is set to +37 dBm (5 watts)
CTS
All other commands stay in the previously established setting.
INIT [4710/9710]
This command sets the transceiver for operation outside the P-20 chassis
by setting the following parameters as shown:
ASENSE
ACTIVE HI
AMASK
FFFF FFFF
RXTOT
NONE
(assert alarm output on all alarms)
(receive time-out timer disabled)
This command can be used prior to using the INIT x720 command to
restore the standard transceiver defaults
INIT [4720/9720]
This command sets the transceiver for operation inside the P-20 chassis
by setting the following parameters as shown:
ASENSE
ACTIVE LO
AMASK
FFFF 0000
RXTOT
20
(trigger on major alarms)
(20 minute time-out timer)
KEY
This command activates the transmitter. See also the DKEY command.
MODEL
This command displays the radioÕs model number code.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
27
MODEM [xxxx, NONE]
This command selects the radioÕs modem characteristics. Enter 9600 for
digital operation, or enter NONE to select analog operation.
OWM [XXX...]
This is a command to display or program an ownerÕs message. To program the ownerÕs message, type OWM then the message, followed by
ENTER .
To display the ownerÕs message, type OWM then
message appears on the display.
ENTER
. The ownerÕs
OWN [XXX...]
This is a command to display or program an ownerÕs name. To program
the ownerÕs name, type OWN then the name, followed by ENTER .
To display the ownerÕs name, type OWN then
appears on the display.
ENTER
. The ownerÕs name
PTT [0Ð255]
This command sets or displays the key-up delay in milliseconds.
This timer specifies how long to wait after the radio receives a key signal
from either the PTT or RTS lines (on the DATA INTERFACE), before actually keying the radio.
PWR [20Ð37]
NOTE: This function may not be available, depending on certification
requirements in a particular country.
This command displays or sets the desired RF forward output power setting of the radio. The PWR command parameter is specified in dBm and
can range from 20 through 37. The default setting is 37 dBm (5 watts).
To read the actual (measured) power output of the radio, use the SHOW
PWR command. A dBm-to-watts conversion chart is provided in
Section 7.5 (page 40).
RSSI
This command continuously displays the radioÕs Received Signal
Strength Indication (RSSI) in dBm units, until you press the Enter key.
Incoming signal strengths from Ð50 dBm to Ð120 dBm can be read.
28
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
RTU [ON/OFF/0-80]
This command re-enables or disables the radioÕs internal RTU simulator, which runs with MDSÕ proprietary polling programs (poll.exe and
rsim.exe). The internal RTU simulator is available whenever a radio has
diagnostics enabled. This command also sets the RTU address that the
radio will respond to.
The internal RTU can be used for testing system payload data or pseudo
bit error rate testing. It can be helpful in isolating a problem to either the
external RTU or the radio.
RX [xxx.xxxx]
This command selects or displays the radioÕs receive frequency in MHz.
The frequency step size is 6.25 kHz.
If the customer frequency has not been programmed at the factory, a
default frequency will be programmed in the radio near the center of the
frequency band.
NOTE: A large change in receive frequency (more than 5 MHz)
requires adjustment of the receiver helical filters for maximum
performance and RSSI. See Section 7.2, Helical Filter Adjustment (page 36) for details.
RXTOT [NONE, 1-255]
The RXTOT command selects or displays the receive time-out timer value
in minutes. This timer triggers an alarm (event 12) if data is not detected
within the specified time.
Entering the RXTOT command without a parameter displays the timer
value in minutes. Entering the RXTOT command with a parameter
ranging from 0 to 255 resets the timer in minutes. Entering the RXTOT
command with the parameter NONE disables the timer.
SCD [0-255]
This command displays or changes the soft-carrier dekey delay in milliseconds.
This timer specifies how long to wait after the removal of the keying
signal before actually releasing the transmitter. A value of 0 milliseconds will unkey the transmitter immediately after the removal of the
keying signal.
SER
This command displays the radioÕs serial number as recorded at the factory.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
29
SHOW [DC, PORT, PWR]
The SHOW command displays different types of information based on
the command variables. The different parameters are:
¥
¥
DCÑDisplay
DC input/output voltages
PORTÑDisplay the connector port (RJ-11 or DB-25) that is active
for diagnostics and control.
¥ PWRÑDisplay RF power output
SNR
This command continuously displays the signal-to-noise ratio of the
received signal expressed in dB, until you press the Enter key. As used
in this guide, the signal-to-noise measurement is based upon the signal
level following equalization, for received frames.
The SNR is an indication of the received signal quality. The SNR indication ranges from 10 dB to 33 dB. A value of 10 dB represents a very
poor signal. A value of 24 dB represents a very good signal.
When the SNR command is used, it causes the DIAG. port to enter an
update mode, and the signal-to-noise ratio is updated and redisplayed
every 2 seconds. The SNR continuously updates until the ENTER key is
pressed.
SREV
This command displays the software revision level of the transceiver
firmware.
STAT
This command displays the current alarm status of the transceiver.
If no alarms exist, the message NO ALARMS PRESENT appears at the top
of the HHT display.
If an alarm does exist, a two-digit code (00Ð31) is displayed and the
alarm is identified as ÒMajorÓ or ÒMinor.Ó A brief description of the
alarm code is also given.
If more than one alarm exists, the word MORE appears at the bottom of
the screen and additional alarms are viewed by pressing the ENTER
key. Detailed descriptions of event codes are provided in Table 9 on
page 33.
TEMP
This command displays the internal temperature of the transceiver in
degrees Celsius.
30
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
TOT [1-255, ON, OFF]
This command sets or displays the transmitter Time-out Timer value
(1Ð255 seconds), as well as the timer status (ON or OFF). If the timer is
on, and the radio remains keyed for a longer duration than the TOT value,
the transmitter is automatically unkeyed.
When this happens, the radio must be commanded back to an unkeyed
state before a new keying command is accepted. The default timer value
is 30 seconds.
TX [xxx.xxxx]
This command selects or displays the radioÕs transmit frequency in
MHz. The frequency step size is 6.25 kHz.
If the customer frequency has not been programmed at the factory, a
default frequency will be programmed in the radio near the center of the
frequency band.
UNIT [10000...65000]
The unit address is factory programmed to the last five digits of the
serial number.
6.0 TROUBLESHOOTING
Successful troubleshooting of the radio system is not difficult, but it
requires a logical approach. It is best to begin troubleshooting at the
master station, as the rest of the system depends on the master for
polling commands. If the master station has problems, the operation of
the entire network can be compromised.
It is good practice to start by checking the simple things. For proper
operation, all radios in the network must meet these basic requirements:
¥ Adequate and stable primary power. The radio contains an internal self-resetting fuse (4A). Remove primary power to reset.
¥ Secure connections (RF, data and power)
¥ An efficient and properly aligned antenna system with a good
received signal strength of at least Ð90 dBm. (It is possible for a
system to operate with weaker signals, but reliability will be
degraded.)
¥ Proper programming of the transceiverÕs operating parameters
(see Section 5.0, TRANSCEIVER PROGRAMMING on page 17).
¥ The correct interface between the transceiver and the connected
data equipment (correct cable wiring, proper data format, timing,
etc.)
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
31
6.1 LED Indicators
The LED status indicators are an important troubleshooting tool and
should be checked whenever a problem is suspected. Table 5 on page 16
describes the function of each status LED.
6.2 Event Codes
When an alarm condition exists, the transceiver creates a code that can
be read on an HHT connected to the DIAG. port. These codes can be very
helpful in resolving many system difficulties. Refer to Table 9 (page 33)
for a definition of the event codes.
Checking for AlarmsÑSTAT command
To check for alarms, enter STAT on the HHT. If no alarms exist, the message NO ALARMS PRESENT appears at the top of the display (Figure 12).
Invisible place holder
Figure 12. HHT Display in Response to STAT Command
If an alarm does exist, a two-digit alarm code (00Ð31) is displayed and
the event is identified as a Major or Minor Alarm. A brief description of
the alarm is also given.
If more than one alarm exists, the word MORE appears at the bottom of
the screen. To view additional alarms, press ENTER .
Major Alarms vs. Minor Alarms
Major AlarmsÑreport serious conditions that generally indicate a hardware failure, or other abnormal condition that will prevent (or seriously
hamper) further operation of the transceiver. Major alarms generally
indicate the need for factory repair. Contact MDS for further assistance.
Minor AlarmsÑreport conditions that, under most circumstances will
not prevent transceiver operation. This includes out-of-tolerance conditions, baud rate mismatches, etc. The cause of these alarms should be
investigated and corrected to prevent system failure.
32
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
Event Code Definitions
Table 9 contains a listing of all event codes that may be reported by the
transceiver.
Table 9. Event Codes
Event
Code
MDS 05-3305A01, Rev. A
Event
Class
Description
01
Major
Improper software detected for this radio model.
02
Major
The model number of the transceiver is unprogrammed.
04
Major
One or both of the internal programmable synthesizer loops is
reporting an out-of-lock condition.
06
Major
An unrecoverable fault was detected on the auto-D chip.l The
radio will not receive data.
07
Major
One or more of the radioÕs internal voltage regulators is
reporting a failure. The radio will not operate.
08
Major
The system is reporting that it has not been calibrated. Factory
calibration is required for proper radio operation.
09
--
10
Major
11
--
12
Major
13Ð15
--
Not used.
16
Minor
Not used.
17
Minor
A data parity fault has been detected on the DATA
INTERFACE connector. This usually indicates a parity setting
mismatch between the radio and the RTU.
18
Minor
A data framing error has been detected on the DATA
INTERFACE connector. This may indicate a baud rate
mismatch between the radio and the RTU.
19Ð24
--
25
Minor
The 5.6 volt power regulator is out-of-tolerance. If the error is
excessive, operation may fail.
26
Minor
The DC input voltage is out-of-tolerance. If the voltage is too
far out of tolerance, operation may fail.
27, 28
--
31
Minor
Not used.
The internal microcontroller was unable to properly program
the system to the appropriate EEPROM defaults. A hardware
problem may exist.
Not used.
Receiver time-out. No data received within the specified
receiver time-out time.
Not used.
Not used
The transceiverÕs internal temperature is approaching an
out-of-tolerance condition. If the temperature drifts outside of
the recommended operating range, system operation may fail.
MDS 4710A/9710A Installation and Operation Guide
33
7.0 TECHNICAL REFERENCE
7.1 MDS 4710A/9710A Transceiver Specifications
TRANSMITTER SYSTEM SPECIFICATION
Operating Frequency:
See Transmitter Specifications
Frequency Stability:
±1.5 ppm
Carrier Power Accuracy:
±1.5 dB (normal1)
±2 dB to -3 dB (extreme2)
Adjacent Channel Power:
Ð60 dBc
Spurious Emissions:
Ð36 dBm, 9 kHz to 1 GHz
Ð30 dBm, 1 GHz to 12 GHz
Intermodulation:
40 dBc
Transmitter Attack Time:
5 ms maximum
Transmitter Release Time:
5 ms maximum
Transient Power
Adjacent Channel:
50 dBc
RECEIVER SYSTEM SPECIFICATION
Operating Frequency:
See Receiver Specifications
Maximum Usable Sensitivity:
Ð113 dBm at 10Ð2 BER (normal1)
Ð107 dBm at 10Ð2 BER (extreme2)
Co Channel Rejection:
Ð12 dB
Adjacent Channel Selectivity:
60 dB (normal1)
50 dB (extreme2)
Spurious Response Rejection:
70 dB
Intermodulation:
65 dB
Blocking:
84 dB
Spurious Radiation:
Ð57 dBm (9 kHz to 1 GHz)
Ð47 dBm (1 GHz to 12.75 GHz)
DATA CHARACTERISTICS
Signalling Standard:
RS-232
Connector:
DB-25 Female
Data Interface Rates:
110Ð38400 bpsÑasynchronous
Data Latency:
10 ms maximum
Byte Length:
10 bits
1. Normal refers to:Temperature, +15 to +35 degrees C
Humidity, 20% to 75%
Voltages, Nominal Specified
2. Extreme refers to:Temperature, Ð25 to +55 degrees C
Humidity, 20% to 75%
Voltages, ±10%
34
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
TRANSMITTER
Frequency Range
One of these bands:
Modulation Type:
Carrier Power:
Duty Cycle:
Output Impedance:
Frequency Stability:
Channel Spacing:
Adjacent Channel Power:
Transmitter Spurious
Conducted Emissions
Operational:
Standby:
Transmitter Spurious
Radiated Emissions:
Harmonics:
2nd harmonic:
3rd harmonic & higher:
Power:
Time-out Timer:
Transmitter Keying:
4710A*
9710A**
380Ð400 MHz
800Ð880 MHz
400Ð450 MHz
880Ð960 MHz
450Ð512 MHz
406Ð530 MHz
*Refer to Figure 4 on page 4 to determine which
band the radio operates on.
**Refer to Figure 5 on page 5 to determine which
band the radio operates on.
Binary CPFSK
0.1 watts to 5 watts
Continuous
50 ohms
±1.5 ppm
12.5 kHz
Ð60 dBc
Ð36 dBm [73 dBc], 9 kHz to 1 GHz
Ð30 dBm [67 dBc], 1 GHz to 12.5 GHz
Ð57 dBm, 9 kHz to 1 GHz
Ð47 dBm, 1 GHz to 12.5 GHz
Ð36 dBm [73 dBc], 9 kHz to 1 GHz
Ð30 dBm [67 dBc], 1 GHz to 12.5 GHz
Ð73 dBc
Ð67 dBc
50 dBc
30 seconds, default (selectable with TOT)
Data activated or RTS
RECEIVER
Frequency Range
One of these bands:
Type:
Frequency Stability:
Maximum Usable Sensitivity:
4710A*
9710A**
380Ð400 MHz
800Ð860 MHz
400Ð420 MHz
860Ð900 MHz
420Ð450 MHz
900Ð960 MHz
450Ð480 MHz
480Ð512 MHz
406Ð430 MHz
*Refer to Figure 4 on page 4 to determine which
band the radio operates on.
**Refer to Figure 5 on page 5 to determine which
band the radio operates on.
Double conversion superheterodyne
1.5 kHz
Ð113 dBm BER at 10Ð2 (normal1)
Ð107dBm BER at 10Ð2 (extreme2)
1. Normal refers to:Temperature, +15 to +35 degrees C
Humidity, 20% to 75%
Voltages, Nominal Specified
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
35
Co-channel Rejection:
Adjacent Channel Rejection:
Spurious
Response Rejection:
Intermodulation
Response Rejection:
Receiver Spurious
Conducted Emissions:
Receiver Spurious
Radiated Emissions:
Bandwidth:
Ð12 dB
60 dB (normal1)
50 dB (extreme2)
70 dB
65 dB
Ð57 dBm, 9 kHz to 1 GHz
Ð47 dBm, 1 GHz to 12.5 GHz
Ð57 dBm, 30 MHz to 1 GHz
Ð47 dBm, 1 GHz to 12.5 GHz
12.5 kHz
PRIMARY POWER
Voltage:
TX Supply Current:
RX Supply Current:
Power Connector:
Fuse:
Reverse Polarity Protection:
13.8 Vdc Nominal (10.5 to 16 Vdc)
2.5 amps
OperationalÑ150 mA
Standby (sleep)Ñ25 mA
2-pin polarized locking connector
4 Amp Polyfuse, Self-Resetting, Internal
(Remove Primary Power to Reset)
Diode across primary input
ENVIRONMENTAL
Humidity:
Temperature Range:
Weight:
Case:
95% at 40 degrees C
Ð30 to 60 degrees C (full performance)
Ð40 to 70 degrees C (operational)
1.6 kilograms
Die-cast Aluminum
DIAGNOSTICS INTERFACE
Signalling Standard:
Connector:
I/O Devices:
RS-232
RJ-11 (may use DB-25 instead if Pin 23 is grounded
to enable diagnostics channel)
MDS Hand Held Terminal or PC with MDS software
7.2 Helical Filter Adjustment
If the frequency of the radio is changed more than 5 MHz, the helical
filters should be adjusted for maximum received signal strength (RSSI).
To adjust the filters, proceed as follows:
1. Remove the top cover from the transceiver by loosening the four
screws and lifting straight up.
2. Extreme refers to:Temperature, Ð25 to +55 degrees C
Humidity, 20% to 75%
Voltages, ±10%
36
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
2. Locate the helical Þlters on the PC board. See Figure 13.
3. Apply a steady signal to the radio at the programmed receive frequency (Ð80 dBm level recommended; no stronger than Ð60 dBm).
This can be done with a signal generator or an over-the-air signal.
4. Measure the radioÕs RSSI using one of the following methods:
¥ With an HHT (See Section 5.0, TRANSCEIVER PROGRAMMING on page 17).
¥ With MDS Radio Configuration Software (See Section 7.4,
Upgrading the RadioÕs Software on page 39).
¥ With a voltmeter connected to Pin 21 of the DATA INTERFACE
connector (See Section 4.2, RSSI Measurement on page 16).
5. With a non-metallic adjustment tool, adjust each section of the
helical Þlters for maximum RSSI. Re-install the cover to the transceiver.
Invisible place holder
U104
U202
U203
FRONT PANEL
OF RADIO
U101
SHIELD
COVER
HELICAL
ADJUSTMENTS
J301
Figure 13. Helical Filter Locations
7.3 Performing Network-Wide Remote Diagnostics
Diagnostics data from a remote radio can be obtained by connecting a
laptop or personal computer running MDS InSite diagnostics software
to any radio in the network. Figure 14 shows an example of a setup for
performing network-wide remote diagnostics.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
37
Invisible place holder
RTU
RTU
DTYPE
NODE
DTYPE
NODE
RTU
TO DATA
TO
PORT
DIAGNOSTICS
PORT
DTYPE
NODE
DTYPE
ROOT
MASTER STATION
ROOT
DIAGNOSTICS DATA
(TO InSite)
PAYLOAD DATA
(TO SCADA APPLICATION)
HOST COMPUTER
Figure 14. Network-Wide Remote Diagnostics Setup
If a PC is connected to any radio in the network, intrusive polling
(polling which briefly interrupts payload data transmission) can be performed. To perform diagnostics without interrupting payload data transmission, connect the PC to a radio defined as the ÒrootÓ radio. A radio
is defined as a root radio using the DTYPE ROOT command locally, at the
radio.
A complete explanation of remote diagnostics can be found in MDSÕ
Network-Wide Diagnostics System Handbook. See the Handbook for
more information about the basic diagnostic procedures outlined below.
1. Program one radio in the network as the root radio by entering the
DTYPE ROOT command at the radio.
2. At the root radio, use the DLINK ON and DLINK [baud rate] commands
to conÞgure the diagnostic link protocol on the RJ-11 port.
3. Program all other radios in the network as nodes by entering the
DTYPE NODE command at each radio.
38
MDS 4710A/9710A Installation and Operation Guide
MDS 05-3305A01, Rev. A
4. Use the DLINK ON and DLINK [baud rate] commands to conÞgure the
diagnostic link protocol on the RJ-11 port of each node radio.
5. Connect same-site radios using a null-modem cable at the radiosÕ
diagnostic ports.
6. Connect a PC on which MDS InSite software is installed to the root
radio, or to one of the nodes, at the radioÕs diagnostic port. (This PC
may be the PC being used to collect payload data, as shown in
Figure 14.)
To connect a PC to the radioÕs DIAG. port, an RJ-11 to DB-9 adapter
(MDS P/N 03-3246A01) is required. If desired, an adapter cable
may be constructed from scratch using the information shown in
Figure 15.
Invisible place holder
RJ-11 PLUG
(TO RADIO)
RJ-11 PIN LAYOUT
DB-9 FEMALE
(TO COMPUTER)
4 TXD
RXD 2
5 RXD
TXD 3
6 GND
GND 5
Figure 15. RJ-11 to DB-9 Adapter Cable
7. Launch the MDS InSite application at the PC. (See the MDS InSite
UserÕs Guide for instructions.)
7.4 Upgrading the RadioÕs Software
Windows-based Radio Configuration software is available (MDS P/N
03-3156A01) for upgrading the internal radio software when new features become available from Microwave Data Systems. Contact MDS
for ordering information.
To connect a PC to the radioÕs DIAG. port, an RJ-11 to DB-9 adapter
(MDS P/N 03-3246A01) is required. If desired, an adapter cable may be
constructed from scratch using the information shown in Figure 15.
Using the Radio Configuration software, select RADIO SOFTWARE
UPGRADE under the SYSTEM menu. Follow the prompts and online
instructions to determine how to proceed.
Software upgrades are distributed as ASCII files with a Ò.S28Ó extension. These files use the Motorola S-record format. When the download
is activated, the radioÕs PWR LED will flash rapidly, confirming that a
download is in process. The download takes about two minutes.
MDS 05-3305A01, Rev. A
MDS 4710A/9710A Installation and Operation Guide
39
NOTE: If a download fails, the radio is left unprogrammed and inoperative. This is indicated by the PWR LED flashing slowly (1
second on/1 second off). This condition is only likely if there
were to be a power failure to the computer or radio during the
downloading process. The download can be attempted again
when the fault has been corrected.
7.5 dBm-Watts-Volts Conversion Chart
Table 10 is provided as a convenience for determining the equivalent
wattage or voltage of an RF power expressed in dBm.
Table 10. dBm-Watts-Volts ConversionÑfor 50 Ohm Systems
40
dBm V
Po
dBm V
Po
dBm mV
+53
+50
+49
+48
+47
+46
+45
+44
+43
+42
+41
+40
+39
+38
+37
+36
+35
+34
+33
+32
+31
+30
+29
+28
+27
+26
+25
+24
+23
+22
+21
+20
+19
+18
+17
+16
+15
+14
+13
+12
+11
+10
+9
+8
+7
+6
+5
+4
+3
+2
+1
200W
100W
80W
64W
50W
40W
32W
25W
20W
16W
12.5W
10W
8W
6.4W
5W
4W
3.2W
2.5W
2W
1.6W
1.25W
1.0W
800mW
640mW
500mW
400mW
320mW
250mW
200mW
160mW
125mW
100mW
80mW
64mW
50mW
40mW
32mW
25mW
20mW
16mW
12.5mW
10mW
8mW
6.4mW
5mW
4mW
3.2mW
2.5mW
2.0mW
1.6mW
1.25mW
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
-11
-12
-13
-14
-15
-16
1.0mW
.80mW
.64mW
.50mW
.40mW
.32mW
.25mW
.20mW
.16mW
.125mW
.10mW
-49
-50
-51
-52
-53
-54
-55
-56
-57
-58
-59
-60
-61
-62
-63
-64
100.0
70.7
64.0
58.0
50.0
44.5
40.0
32.5
32.0
28.0
26.2
22.5
20.0
18.0
16.0
14.1
12.5
11.5
10.0
9.0
8.0
7.10
6.40
5.80
5.00
4.45
4.00
3.55
3.20
2.80
2.52
2.25
2.00
1.80
1.60
1.41
1.25
1.15
1.00
.90
.80
.71
.64
.58
.500
.445
.400
.355
.320
.280
.252
.225
.200
.180
.160
.141
.125
.115
.100
.090
.080
.071
.064
.058
.050
.045
.040
.0355
dBm µV
dBm mV
-17
-18
-19
-20
-21
-22
-23
-24
-25
-26
-27
-28
-29
-30
-31
-32
-33
-34
-35
-36
-37
-38
-39
-40
-41
-42
-43
-44
-45
-46
-47
-48
31.5
28.5
25.1
22.5
20.0
17.9
15.9
14.1
12.8
11.5
10.0
8.9
8.0
7.1
6.25
5.8
5.0
4.5
4.0
3.5
3.2
2.85
2.5
2.25
2.0
1.8
1.6
1.4
1.25
1.18
1.00
0.90
Po
.01mW
.001mW
.1µW
MDS 4710A/9710A Installation and Operation Guide
-65
-66
-67
-68
-69
-70
-71
-72
-73
-74
-75
-76
-77
-78
-79
-80
-81
-82
-83
-84
-85
-86
-87
-88
-89
-90
-91
-92
-93
-94
-95
-96
-97
Po
0.80
0.71 .01µW
0.64
0.57
0.50
0.45
0.40
0.351
0.32
0.286
0.251
0.225 .001µW
0.200
0.180
0.160
0.141
128
115
100
90
80
71
65
58
50
45
40
35
32
29
25
22.5
20.0
18.0
16.0
11.1
12.9
11.5
10.0
9.0
8.0
7.1
6.1
5.75
5.0
4.5
4.0
3.51
3.2
Po
.1nW
.01nW
.001nW
dBm µV
-98
-99
-100
-101
-102
-103
-104
-105
-106
2.9
2.51
2.25
2.0
1.8
1.6
1.41
1.27
1.18
dBm nV
-107
-108
-109
-110
-111
-112
-113
-114
-115
-116
-117
-118
-119
-120
-121
-122
-123
-124
-125
-126
-127
-128
-129
-130
-131
-132
-133
-134
-135
-136
-137
-138
-139
-140
1000
900
800
710
640
580
500
450
400
355
325
285
251
225
200
180
160
141
128
117
100
90
80
71
61
58
50
45
40
35
33
29
25
23
Po
.1pW
Po
.01pW
.001pW
.1ÄW
.01ÄW
MDS 05-3305A01, Rev. A
INDEX
ACCESS DENIED error message 20
Accessories 5
Accessory Power pinout (Pin 18) 15
Active messaging (deÞned) 6
Alarms
alarm code deÞnitions 33
major vs. minor 32
pinout (Pin 25) 15
using STAT command to display 30
AMASK command 23
Antenna
installation 9
RSSI command used to reÞne heading 16
system gain, deÞned 6
Yagi, illustrated 12
Antennas 11Ð12
Applications 2
Multiple Address Systems (MAS) 2
point-to-multipoint system 2
point-to-point system 3
ASENSE command 24
BAUD command 24
Baud rate
setting for RJ-11 DIAG port (DLINK command) 26, 38
Bit, deÞned 6
Bits-per-second. See BPS 6
BPS (bits-per-second), deÞned 6
BUFF command 24
Byte, deÞned 6
Cable, loss due to length of coaxial at 400 MHz 12
Cable, loss due to length of coaxial at 960 MHz 12
Cautions
use attenuation between all units in test setup 38
CKEY command 25
COMMAND FAILED error message 20
Command summary, table 21
Commands
AMASK (set/display alarm triggers) 23
ASENSE (set alarm output state) 24
BAUD (set/display rate, encoding) 24
BUFF (set/display data handling mode) 24
CKEY (enable/disable continuous keying) 25
CTS (set/display CTS line response timer) 25
MDS 05-3324A01, Rev. A
DATAKEY (enable/disable transmitter keying by radio) 25
descriptions 22Ð31
DEVICE (set/display radio behavior) 25
DKEY (deactivate transmitter after KEY command) 26
DLINK (enable/disable network-wide diagnostics) 26
DMGAP (set time to wait between characters) 26
DTYPE (set radio to root or node for diagnostics) 26
DUMP (display all programmed settings) 26
entering on Hand-Held Terminal (HHT) 19
Hand-Held Terminal (HHT) 19
HREV (display hardware revision level) 26
INIT (reinitialize radio to factory defaults) 27
INIT xx10 (restore standard transceiver defaults) 27
INIT xx20 (conÞgure radio for use with P-20 chassis) 27
KEY (activate transmitter) 27
MODEL (display radio model number code) 27
MODEM (set modem speed) 28
OWM (set/display ownerÕs message) 28
OWN (set/display ownerÕs name) 28
PTT (set/display key-up delay) 28
PWR (set/display RF forward output power) 28
RSSI (display RSSI) 28
RTU (enable/disable internal RTU) 29
RX (set/display receive frequency) 29
RXTOT (set/display receive time-out timer value) 29
SCD (set/display soft-carrier dekey delay) 29
SER (display radio serial number 29
SHOW (display DC voltage, data port, RF power) 30
SNR (display signal-to-noise ratio) 30
SREV (display software revision level) 30
STAT (display current alarm status) 30
TEMP (display internal temperature) 30
TOT (set/display time-out value and timer status) 31
TX (set/display transmit frequency) 31
Conversions, dBm-Watts-Volts 40
CTS command 25
CTS pinout (Pin 5) 14
Data interface
connector pinouts 14
display active connector port 30
installing connection 13
DATAKEY command 25
dB. See Decibel 6
dBi, deÞned 6
dBm, deÞned 6
DCD
LED 16
pinout (Pin 8) 14
Installation and Operation Guide
I-1
DCE (Data Cirtuit-terminating Equipment), deÞned 6
Decibel (dB), deÞned 6
Description, product 1
DEVICE command 25
Diagnostic Channel Enable, pinout (Pin 23) 15
Diagnostics
interface speciÞcations 36
network-wide, performing 37
PC software used for 39
using InSite software for network-wide 37
Display
alarm status (STAT command) 30
alarm triggers (AMASK command) 23
all programmed settings (DUMP command) 26
baud rate and encoding (BAUD command) 24
connector port, active (SHOW command) 30
CTS line response timer (CTS command) 25
data handling mode (BUFF command) 24
DC voltage (SHOW command) 30
hardware revision leve (HREV command)l 26
key-up delay (PTT command) 28
model number code (MODEL command) 27
ownerÕs message (OWM command) 28
ownerÕs name (OWN command) 28
radio behavior (DEVICE command) 25
radio serial number (SER command) 29
receive frequency (RX command) 29
receive time-out timer value (RXTOT command) 29
RF forward output power (PWR command) 28
RF output (SHOW command) 30
RSSI (RSSI command) 28
signal-to-noise ratio (SNR command) 30
soft-carrier dekey delay (SCD command) 29
software revision level (SREV command) 30
temperature, internal (TEMP command) 30
time-out value and timer status (TOT command) 31
transmit frequency (TX command) 31
DKEY command 26
DLINK command 26
use of 38
DMGAP command 26
Downloading new software 39
DSP (Digital Signal Processing), deÞned 7
DSR pinout (Pin 6) 14
DTE (Data Terminal Equipment), deÞned 7
DTYPE command 26
use of 38
DUMP command 26
EEPROM FAILURE error message 20
Enable/disable
continuous keying (CKEY command) 25
diagnostic channel, pinout (Pin 23) 15
internal RTU (RTU command) 29
network-wide diagnostics (DLINK command) 26
network-wide diagnostics, procedures 38
Environment speciÞcations 36
MDS 05-3324A01, Rev. A
Equalization, deÞned 7
Error messages 20
access denied 20
command failed 20
EEPROM failure 20
incorrect entry 20
not available 20
not programmed 20
text too long 20
unknown command 20
Fade margin, deÞned 7
Feedlines 12
Filter, helical, adjustment 36
Frame, deÞned 7
Frequency
adjusting helical Þlter when changed 36
setting. See TX and RX commands
Glossary 6
Ground
on Pin 12 to enable Sleep mode 14
protective (Pin 1) 14
signal (Pin 7) 14
Half-duplex 3
switched carrier operation 4
Hand-Held Terminal (HHT) 5
connected to transceiver, illustrated 18
connection and startup 17
display in response to STAT command, illustrated 32
entering commands 19
error messages displayed on 20
keyboard commands 19
operational settings, table 19
reinitialization display, illustrated 19
reinitializing 18
Hardware ßow control, deÞned 7
Helical Þlter
adjusting 36
illustration 37
Host computer, deÞned 7
HREV command 26
Illustrations
4710A model number codes 4
9710A model number codes 5
antenna, Yagi 12
Hand-Held Terminal (HHT) connected to transceiver 18
Installation and Operation Guide
I-2
Illustrations (Continued)
Hand-Held Terminal (HHT) reinitialization display 19
Hand-Held Terminal display in response to STAT command 32
helical Þlter locations 37
MAS network 3
network-wide diagnostics 38
point-to-point link 3
remote station arrangement 9
RJ-11 to DB-9 adapter cable 39
RSSI vs. Vdc 13, 17
transceiver connectors & indicators 2
transceiver mounting dimensions 11
INCORRECT ENTRY error message 20
INIT command 27
INIT xx10 command 27
INIT xx20 command 27
InSite software
using to perform remote diagnostics 37
Installation 9Ð15
antenna 9
conÞguring transceiver 10
DATA INTERFACE connection 10
data interface connections 13
power 10
power connection 13
steps 9
Intrusive diagnostics (deÞned) 7
Master Station
NOT AVAILABLE error message 20
deÞned 7
keying behavior 3
MCU (Microcontroller Unit), deÞned 7
MODEL command 27
Model number codes 4
4710A, illustrated 4
9710A, illustrated 5
displaying (MODEL command) 27
MODEM command 28
Modem, set speed. See MODEM command
Network-wide diagnostics
active messaging, deÞned 6
deÞned 8
enable/disable (DLINK command) 26
enable/disable internal RTU (RTU command) 29
illustrated 38
intrusive diagnostics, deÞned 7
passive messaging (deÞned) 8
procedures 37
set radio to root or node (DTYPE command) 26
set time to wait between characters (DMGAP command) 26
KEY command 27
Keying
continuously keyed versus switched carrier operation 3
continuously keyed, deÞned 3
on data (DKEY command) 26
switched carrier, deÞned 4
NOT PROGRAMMED error message 20
Operation 15
environment speciÞcations for 36
Output, 9.9 Vdc regulated, pinout (Pin 19) 15
Latency, deÞned 7
LEDs
DCD 16
indicators, described 16
PWR 16
RXD 16
RXD, Pin 3 14
status indicators, illustrated 16
TXD 16
TXD, Pin 2 14
Loss. See Signal
OWM command 28
OWN command 28
OwnerÕs message, set/display. See OWM command
OwnerÕs name, set/display. See OWN command
Passive messaging (deÞned) 8
Payload data (deÞned) 8
Pinouts on data interface 14
PLC (Programmable Logic Controller), deÞned 8
Point-to-multipoint
deÞned 8
MAS (Multiple Address System) 2
deÞned 7
illustration 3
MDS 05-3324A01, Rev. A
system 2
Point-to-point
link, illustrated 3
system 3
Poll, deÞned 8
Installation and Operation Guide
I-3
Power
See also PWR
connection 13
display DC voltage (SHOW command) 30
display RF output (SHOW command) 30
installing 10
LED status indicator (PWR LED) 16
RF, chart for converting dBm-Watts-Volts 40
speciÞcations 36
Procedures
checking for alarms (STAT command) 32
connecting Hand-Held Terminal (HHT) 17
downloading new software 39
entering commands using the Hand-Held Terminal (HHT) 19
helical Þlter adjustment 36
installation 9
measuring RSSI with DC voltmeter 16
network-wide diagnostics 37
operation 15
performance optimization 16
reading LED status indicators 16
resetting Hand-Held Terminal (HHT) 18
troubleshooting 31Ð33
Product
accessories 5
description 1
display model number code (MODEL command) 27
display radio serial number (SER command) 29
model number codes 4
Programming radio as root or node 38
Programming, transceiver 17Ð31
PTT
command 28
pinout (Pins 14, 16) 14
PWR
command 28
LED 16
Revision level
display hardware (HREV command) 26
display software (SREV command) 30
RSSI
adjusting helical Þlter for increased signal strength 36
command 28
command, used to reÞne antenna heading 16
measuring 16
pinout (Pin 21) 15
vs. Vdc, illustrated 13, 17
RTS pinout (Pin 4) 14
RTU
command 29
RTU (Remote Terminal Unit)
deÞned 8
remote reset (Pin 15) 15
RUS pinout (Pin10) 14
RX command 29
RXD LED
description 16
Pin 3 14
RXTOT command 29
SCADA (Supervisory Control And Data Acquisition), deÞned 8
SCD command 29
SER command 29
Set
alarm output state (ASENSE command) 24
alarm triggers (AMASK command) 23
receive time-out timer value (RXTOT command) 29
SHOW command 30
Signal
Radio
ConÞguration Software 5, 39
Inhibit pinout (Pin 12) 14
serial number, displaying (SER command) 29
Receive Audio Output pinout (Pin 11) 14
Receiver
speciÞcations 35
system speciÞcations 34
unsquelched signal (Pin 10) 14
Redundant operation, deÞned 8
Remote
RTU reset (Pin 15) 15
Station, deÞned 8
Station, illustrated 9
Resetting
Hand-Held Terminal (HHT) (SHIFT,CTRL,SPACE keys) 18
remote RTU reset (Pin 15) 15
transceiver (INIT command) 27
MDS 05-3324A01, Rev. A
ground (Pin 7) 14
loss due to coaxial cable length at 960 MHz, table 12
loss due to coaxial cable length, table 12
Simplex 3
single-frequency operation 4
special case of switched carrier operation 4
Sleep mode
example implementation 13
ground on Radio Inhibit pin activates 14
Pin 12 14
shown by PWR LED status indicator 16
SNR command 30
Software
diagnostics and control used from PC 39
display revision level 30
upgrades (.S28 Þles) 39
upgrading 39
used for diagnostics and programming 17
Installation and Operation Guide
I-4
U
SpeciÞcations
diagnostics interface 36
environment 36
power 36
receiver 35
receiver system 34
transceiver 34Ð36
transmitter 35
transmitter system 34
SREV command 30
STAT command 30
SWR (Standing Wave Radio), deÞned 9
UNKNOWN COMMAND error message 20
Tables
accessories 5
alarm code deÞnitions 33
command summary 21
conversions, dBm-Watts-Volts 40
data interface connector pinouts 14
Hand-Held Terminal (HHT) operational settings 19
LED status indicators 16
length vs. loss in coaxial cables 12
length vs. loss in coaxial cables at 960 MHz 12
Technical reference 34Ð40
TEMP command 30
Temperature, displaying internal (TEMP command) 30
TEXT TOO LONG error message 20
Timer, set/display time-out value and status (TOT command) 31
TOT command 31
Transceiver
applications 2
conÞguring for operation 10
connectors and indicators, illustrated 2
diagnostics using PC software 39
dimensions, mounting 11
mounting 9, 11
programming 17Ð31
speciÞcations 34Ð36
upgrading software 39
Transmit Audio Input pinout (Pin 9) 14
Transmitter
speciÞcations 35
system speciÞcations 34
Troubleshooting 31Ð33
connecting Hand-Held Terminal (HHT) for displaying alarm
codes 17
performing network-wide diagnostics 37
STAT command (Status) 32
using PC software for 39
TX command 31
TXD LED
description 16
Pin 2 14
MDS 05-3324A01, Rev. A
Installation and Operation Guide
I-5
NOTES
NOTES
NOTES
IN CASE OF DIFFICULTY...
MDS products are designed for long life and trouble-free operation. However, this equipment, as
with all electronic equipment, may have an occasional component failure. The following information will assist you in the event that servicing becomes necessary.
FACTORY TECHNICAL ASSISTANCE
Technical assistance for MDS products is available from our Customer Support Team during
business hours (8:00 A.M.Ð5:30 P.M. Eastern Time). When calling, please give the complete
model number of the radio, along with a description of the trouble symptom(s) that you are experiencing. In many cases, problems can be resolved over the telephone, without the need for
returning the unit to the factory.
Please use the following telephone numbers for product assistance:
716-242-9600 (Phone)
716-242-9620 (FAX)
FACTORY REPAIRS
Component level repair of radio equipment is not recommended in the field. Many components
are installed using surface mount technology, which requires specialized training and equipment
for proper servicing. For this reason, the equipment should be returned to the factory for any PC
board repairs. The factory is best equipped to diagnose, repair and align your radio to its proper
operating specifications.
If return of the equipment is necessary, you will be issued a Returned Material Authorization
(RMA) number. The RMA number will help expedite the repair so that the equipment can be
repaired and returned to you as quickly as possible. Please be sure to include the RMA number on
the outside of the shipping box, and on any correspondence relating to the repair. No equipment
will be accepted for repair without an RMA number.
A statement should accompany the radio describing, in detail, the trouble symptom(s), and a
description of any associated equipment normally connected to the radio. It is also important to
include the name and telephone number of a person in your organization who can be contacted if
additional information is required.
The radio must be properly packed for return to the factory. The original shipping container and
packaging materials should be used whenever possible. All factory returns should be addressed to:
Microwave Data Systems
Customer Service Department
(RMA No. XXXX)
175 Science Parkway
Rochester, NY 14620 USA
When repairs have been completed, the equipment will be returned to you by the same shipping
method used to send it to the factory. Please specify if you wish to make different shipping
arrangements.
175 Science Parkway, Rochester, New York 14620
General Business: +1 (716) 242-9600
FAX: +1 (716) 242-9620
World Wide Web: http://www.mdsroc.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 1999:02:18 13:49:16
Producer                        : Acrobat Distiller 3.01 for Power Macintosh
Author                          : Microwave Data Systems
Title                           : 3305 4710A  and 9710A  Transceiver Installation and Operation Guide
Creator                         : FrameMaker 5.5.3
Modify Date                     : 2000:09:06 13:23:35-04:00
Subject                         : MDS 4710A and 9710A
Keywords                        : 3305, 4710A, 9710A, Transceiver, remote, 400MHz, 900MHz, Network-wide, diagnostics
Page Count                      : 56
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
EXIF Metadata provided by EXIF.tools
FCC ID Filing: E5MDS9710-1

Navigation menu