Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies 4/9/01 340M OB Telemetry Simplified Operating Instructions Overview: The 340M OB Telemetry system is comprised of a transmitter and receiver to provide an RF link between patient worn transducers and fetal monitor, allowing patient to freely move about while staff monitor fetal heart rate and uterine contractions remotely. The 341 Receiver is line powered from 120 VAC, and the 342 Transmitter is powered from (4) AA size primary Alkaline cells. Expected life of the Alkaline cells in continuous use is roughly 16 Hrs. There are two simulators used for exercising the transmitter. One is a production simulator (Model 325) and the other is a radiation hardened simulator (built into a metal box). The 325 simulator will be used for SAR testing and the radiation hardened will be used for other testing. Other accessories are provided for their use in testing, if necessary. Descriptions: (refer also to 340 Service manual, pages 3-2,3,4) 341 Receiver: Front Panel: AC power switch far right Toco/Iup mode change switch left Indicator lamps center right Signal strength indicator, green top Battery status, red center AC mains, green bottom Rear Panel: Power Entry Module far left top Mark interconnect cable Jack far left bottom System Interconnect cable jack left bottom Ultrasound interconnect cable jack bottom center ECG interconnect cable jack bottom right UA interconnect cable jack bottom far right Equipotential ground jack top center Page 1 of 8 Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies Antenna jack (RA female BNC) Connect to ¼ wave stainless whip 4/9/01 top center 342 Transmitter: Front Panel: Ultrasound Transducer jack left ECG Transducer jack center UA transducer jack right Rear Panel: Headphone jack far left Remote mark transducer jack left Power switch right Antenna jack (BNC) Connect to ¼ wave helical wound ant. far right Bottom Panel: Battery access door Radiation Hardened Simulator (for use at ITS, Boxborough): This is an aluminum die-cast box containing (2) Alkaline ‘D’ cells providing power, and active circuitry providing signal to the 5700 Ultrasound Transducers and UA Transducer plug. Top: Power switch: Must be in the ‘ON’ position to obtain simulated transducer signal. Turn ‘OFF’ when not needed to conserve battery. UA Ref pushbutton: Forces UA simulated signal to a baseline level for physiologic signal drift testing. Not used for RF testing. Adjustment Potentiometer: Allows UA simulated signal to be offset from baseline level by adjustable amount. Not used for RF testing. Page 2 of 8 Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies 4/9/01 Side: (4) Gray Cables total - Gray cable, no plug: Not used -Gray cable, 5700 Transducer at end, nothing beyond Not used -Gray cable, 5700 Transducer at end, mechanically face connected to slave 5700 transducer This slave 5700 plug connects to Ultrasound input jack of the 342 transmitter. -Gray cable, round 12 pin white connector at end This plugs into the UA connector jack of the 342 Transmitter. 325 Maternal/Fetal Simulator (for use at ITS, Menlo Park, SAR): Front Panel: FECG/MECG section: RATE bpm: Set to 120 QRS AMPLITUDE: Set to 2000 CMR: Set to BAL MODE: Set to FECG QRS POLARITY: Set to (+) ULTRASOUND/FMD section: RATE bpm: Set to 120 SIGNAL LEVEL: Set to HIGH MODE: Set to US/FMD UA Section Black Slide Switch: Page 3 of 8 Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies 4/9/01 Left position LEVEL mmHg: Set to 100 MODE: Set to TOCO Bottom Center section MANUAL ADJUSTMENT: Full clockwise PATTERN MEMORY: ON Bottom Right POWER indicator: Glows green when AC power connected and rear panel switch depressed Rear Panel: Power inlet: Connect IEC style power cord to 120 VAC Power button: Push on/ Push off style button. 325 must be powered on for testing. Cable Harness, Front Panel: From Top Center (3) gray cables are connected from ‘CONNECT TO FETAL MONITOR’ connector. -Round white to UA input jack of 341 Transmitter -Round Gray/Blue to ULTRASOUND input jack of 341 Transmitter -Round dark gray to ECG input jack of 341 Transmitter Procedure: 1) Identify packed items. - 341M Telemetry Receiver - Line cord - System Interconnect cable #1563AAO - Mark interconnect cable #1397AAO - US interconnect cable #1399BAO - ECG interconnect cable #1375AAO - UA interconnect cable #1400AAO - Quarter wave stainless whip antenna (receiver) Page 4 of 8 Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies 4/9/01 - 342M Telemetry Transmitter - Black Helical antenna (transmitter) - 3 sets of AA batteries - Remote Mark transducer #3919BAO - Softrans Cable #1336AAO - Softrans Intrauterine Pressure Catheter #2076AAO - Ultrasound Transducer #5700AAX - Toco transducer, #2264LAX - Headset #3316AAO - Qwik Connect Plus Legplate interface cable, #1590AAO - Radiation Hardened Simulator, (no marking) Boxborough site - Model 325 Simulator, Menlo Park site 2) For tests involving fully modulated transmitter signals, interconnect system as shown: Boxborough, MA: Headset (3316AAO) Helical Ant. Ultrasound (2) 5700 transducers face to face 342M Transmitter (power switch on) Boxborough: RF Hardened Simulator Uterine Activity (Power switch on) ECG 1590AAO Legplate stainless whip ant. AC Power 341M Receiver (power switch on) (green signal strength LED indicates transmitter active) Remote Mark pushbutton (3919BAO) System Interconnect cable #1563AAO Mark interconnect cable #1397AAO US interconnect cable #1399BAO ECG interconnect cable #1375AAO UA interconnect cable #1400AAO Page 5 of 8 Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies 4/9/01 3) Description of System as connected above. Input to modulate transmitter is derived from simulator. Can be monitored via headset. Uterine activity modulation derived from simulator. ECG modulation derived from simulator. Helical antenna radiates modulated RF to 341 Receiver. 341 Receiver intercepts RF via ¼ wave stainless whip antenna. 341 Receiver signal strength LED indicates transmitter active. Page 6 of 8 Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies 4/9/01 Menlo Park Configuration: Headset (3316AAO) Helical ant. Ultrasound 342M Transmitter (power switch on) Menlo Park: Model 325 Simulator Uterine Activity (Power switch on) ECG stainless whip AC Power Remote Mark pushbutton (3919BAO) 341M Receiver System Interconnect cable #1563AAO Open (5) (power switch on) Mark interconnect cable #1397AAO (green signal strength LED indicates transmitter active) US interconnect cable #1399BAO ECG interconnect cable #1375AAO UA interconnect cable #1400AAO Page 7 of 8 Simplified Operating Instruction, 340M OB Telemetry, 608-614MHz GE Medical Systems Information Technologies 4/9/01 3) Description of System as connected above. Input to modulate transmitter is derived from simulator. Can be monitored via headset. Uterine activity modulation derived from simulator. ECG modulation derived from Model 325 simulator. Helical antenna radiates modulated RF to 341 Receiver. 341 Receiver intercepts RF via ¼ wave stainless whip antenna. 341 Receiver signal strength LED indicates transmitter active. Page 8 of 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2001:06:18 10:48:22 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2001:06:18 10:48:24-04:00 Page Count : 8EXIF Metadata provided by EXIF.tools